Motivation Methods References Future Directions In 2008, there were 7.6 million deaths due to cancer. Over 3 million of these deaths were in epithelial tissues. Examples of epithelial cancers are lung, stomach, liver, colorectal, breast and skin cancer. Convert bench top design into a handheld prototype Install mechanism to prevent backflow of fluid into probe Increase Raman collection efficiency Clinical testing to examine effectiveness on human tissue [1] Patil, C.A. (2009). Development combined raman spectroscopy-optical coherence tomograpgy for the detection of skin cancer. Dissertation submitted to faculty of Graduate school of Vanderbilt University. [2] Munce, N.R. and Yang, V.X.D. et al.(2008). Electrostatic forward-viewing scanning probe for doppler optical coherence tomography using a dissipative polymer catheter. Optical letters, 33, 7, 657-60. [3] Liu X, Cobb MJ, Chen Y, Kimmey MB, Li X. "Rapid- scanning forward-imaging miniature endoscope for real-time Fiber Optic Sample Arm for Raman Spectroscopy (RS) and Optical Coherence Tomography (OCT) Probe John Acevedo, Chris Miller, and Kelly Thomas Background Design Criteria RS and OCT can be combined to more effectively detect epithelial cancers. RS and OCT are complimentary. OCT is able to produce real-time images with micron scale structural resolution RS is able to give biochemical specificity. The current RS-OCT sample arm measures 5”x8”x3”. Problem Statement The bulkiness of the sample arm limits sampling to large portions of the skin, thus inhibiting sampling at both hard to reach areas on the skin and in vivo tissues. Facilitate the use of the sample arm of the current RS- OCT probe by miniaturizing the sample arm. Create a working fiber optic sample arm bench top design using multi-mode fibers and single-mode fibers. Allow spatial co-registration of RS-OCT so that the design configuration will not comprise the collection efficiency of either RS or OCT. Decrease size of probe to < 1 cm in diameter Reach a scan rate OCT > 4 frames per second Reach an axial scan range of at least 2.4 mm depth Spot size for OCT should be < 27 μm over imaging range Reach a transverse scan range of at least 5 mm RS collection efficiency of <10 seconds OCT Methods: 1.Scanning capabilities of various piezoelectric actuators were tested. 2.Measured optical length of existing sampling arm and calculated the length of the overall air space from fiber tip to image plane in order to determine the ideal length of the new sample arm. 3.Calculated the scan shape based on the position of the pivot point 4. GRIN lens was positioned and single mode fiber was cut to match the existing sample arm. 5. Configured bench top design with easily adjustable mounts. 6. The 1-D reflectance profile was measured using a plane mirror. RS Methods: 4.Raman illumination and collection fibers were integrated into the GRIN lens lumen. Combined RS & OCT Methods: 5.The collection efficiency of the fibers was measured using phantom sample. 6.Images were compared to original sample arm images. Figure 4: This shows the scanning ability of the fiber-optic piezoelectric OCT bench top design. The left image shows the beam spot size with no scanning, and the right image shows the spot size during piezoelectric scanning. The piezoelectric has a resonance frequency of 110 Hz. Figure 3: The fiber optic probe has a white fiber running along a piezoelectric actuator. Both components protrude from a green housing connected to a stage to allow precise 3D placement of the fiber with respect to the GRIN lens. Acknowledgements We would like to thank our advisors Dr. Mahadevan-Jansen and Dr. Chetan Patil. We would also like to thank our professor Dr. King and the National Institutes of Health - National Cancer Institute (R21 CA133477-01/02) Figure 7: The scan geometry used to calculate the scan shape. Transverse scan range was 2.31 mm. Discussion A fiber optic RS-OCT probe is feasible using piezoelectric actuators to provide the scanning motion of the OCT. We demonstrated that a scanning beam > 4 frames per second could be created while keeping the size of the probe less than 1 cm in diameter. The small footprint of the OCT portion of the probe allows raman fibers Results 0.9 1 1.1 1.2 1.3 1.4 x 10 4 0 5 10 15 20 25 30 D istance to Im age (um ) G aussian B eam Diam eter(um) D istance to Im age vs.B eam Diameter Gaussian Beam diameter(μm) Distance to Image vs. Beam Diameter Distance to Image (μm) Figure 8: At d1 (see Figure 5), the beam diameter is 27 μm over a scanning range of 2.4 mm. This occurs at 10-12 mm from the lens to the image plane. Figure 1: Current RS-OCT probe 58 Figure 2: TOP: OCT image of breast epithelial tissue. BOTTOM: RS spectrum spatially co-registered with OCT. Raman Fiber Tylenol GRIN Lens Raman Fibers OCT Fiber Figure 5: OCT Reflectance Profile of Tylenol tablet shown in Figure 3. Feasibility of Miniaturization Feasibility of Scanning Feasibility of RS-OCT Data Acquisition 0 200 400 600 800 1000 1200 1400 1600 1800 2000 600 620 640 660 680 700 720 740 760 Raman Shift (wave numbers 1/cm) Raman Intensity 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 -500 1500 3500 5500 7500 9500 Distance (mm) Reflectance Figure 6: Raman spectrum of Tylenol tablet shown in Figure 3.

description

Fiber Optic Sample Arm for Raman Spectroscopy (RS) and Optical Coherence Tomography (OCT) Probe John Acevedo, Chris Miller, and Kelly Thomas. 8”. 5 ”. Distance to Image vs. Beam Diameter. Gaussian Beam diameter( μ m). Distance to Image ( μ m). Motivation. Methods. Results. - PowerPoint PPT Presentation

Transcript of Motivation

Page 1: Motivation

Motivation Methods

References

Future Directions

In 2008, there were 7.6 million deaths due to cancer. Over 3 million of these deaths were in epithelial tissues.

Examples of epithelial cancers are lung, stomach, liver, colorectal, breast and skin cancer.

Convert bench top design into a handheld prototype Install mechanism to prevent backflow of fluid into probe Increase Raman collection efficiency Clinical testing to examine effectiveness on human tissue

[1] Patil, C.A. (2009). Development combined raman spectroscopy-optical coherence tomograpgy for the detection of skin cancer. Dissertation submitted to faculty of Graduate school of Vanderbilt University.[2] Munce, N.R. and Yang, V.X.D. et al.(2008). Electrostatic forward-viewing scanning probe for doppler optical coherence tomography using a dissipative polymer catheter. Optical letters, 33, 7, 657-60.[3] Liu X, Cobb MJ, Chen Y, Kimmey MB, Li X. "Rapid-scanning forward-imaging miniature endoscope for real-time optical coherence tomography" Optics Letters,Vol. 29, Issue 15, pp. 1763-1765 (2004).

Fiber Optic Sample Arm for Raman Spectroscopy (RS) and Optical Coherence Tomography (OCT) Probe

John Acevedo, Chris Miller, and Kelly Thomas

Background

Design Criteria

RS and OCT can be combined to more effectively detect epithelial cancers. RS and OCT are complimentary.

OCT is able to produce real-time images with micron scale structural resolution RS is able to give biochemical specificity.

The current RS-OCT sample arm measures 5”x8”x3”.

Problem Statement The bulkiness of the sample arm limits sampling to large portions of the skin, thus inhibiting sampling at both hard to reach areas on the skin and in vivo tissues. Facilitate the use of the sample arm of the current RS- OCT probe by miniaturizing the sample arm. Create a working fiber optic sample arm bench top design using multi-mode fibers and single-mode fibers. Allow spatial co-registration of RS-OCT so that the design configuration will not comprise the collection efficiency of either RS or OCT.

Decrease size of probe to < 1 cm in diameter Reach a scan rate OCT > 4 frames per second Reach an axial scan range of at least 2.4 mm depth Spot size for OCT should be < 27 μm over imaging range Reach a transverse scan range of at least 5 mm RS collection efficiency of <10 seconds

OCT Methods:1. Scanning capabilities of various piezoelectric actuators were tested.2. Measured optical length of existing sampling arm and calculated the

length of the overall air space from fiber tip to image plane in order to determine the ideal length of the new sample arm.

3. Calculated the scan shape based on the position of the pivot point

4. GRIN lens was positioned and single mode fiber was cut to match the existing sample arm.

5. Configured bench top design with easily adjustable mounts.6. The 1-D reflectance profile was measured using a plane mirror.RS Methods:4. Raman illumination and collection fibers were integrated into the GRIN

lens lumen.Combined RS & OCT Methods:5. The collection efficiency of the fibers was measured using phantom

sample.6. Images were compared to original sample arm images.

Figure 4: This shows the scanning ability of the fiber-optic piezoelectric OCT bench top design. The left image shows the beam spot size with no scanning, and the right image shows the spot size during piezoelectric scanning. The piezoelectric has a resonance frequency of 110 Hz.

Figure 3: The fiber optic probe has a white fiber running along a piezoelectric actuator.  Both components protrude from a green housing connected to a stage to allow precise 3D placement of the fiber with respect to the GRIN lens.

AcknowledgementsWe would like to thank our advisors Dr. Mahadevan-Jansen and Dr. Chetan Patil. We would also like to thank our professor Dr. King and the National Institutes of Health - National Cancer Institute (R21 CA133477-01/02)

Figure 7: The scan geometry used to calculate the scan shape. Transverse scan range was 2.31 mm.

Discussion A fiber optic RS-OCT probe is feasible using piezoelectric actuators to provide the scanning motion of the OCT. We demonstrated that a scanning beam > 4 frames per second could be created while keeping the size of the probe less than 1 cm in diameter. The small footprint of the OCT portion of the probe allows raman fibers to be closely integrated into the design. This close integration allows the spatial co-registration of RS and OCT to be accurate.

Results

0.9 1 1.1 1.2 1.3 1.4

x 104

0

5

10

15

20

25

30

Distance to Image (um)

Gau

ssia

n B

eam

Dia

met

er (u

m)

Distance to Image vs. Beam Diameter

Gau

ssia

n B

eam

dia

met

er(μ

m)

Distance to Image vs. Beam Diameter

Distance to Image (μm)

Figure 8: At d1 (see Figure 5), the beam diameter is 27 μm over a scanning range of 2.4 mm. This occurs at 10-12 mm from the lens to the image plane.

Figure 1: Current RS-OCT probe

5”

8”

Figure 2: TOP: OCT image of breast epithelial tissue. BOTTOM: RS spectrum spatially co-registered with OCT.

Raman Fiber

Tylenol

GRIN LensRaman Fibers

OCT Fiber

Figure 5: OCT Reflectance Profile of Tylenol tablet shown in Figure 3.

Feasibility of Miniaturization

Feasibility of Scanning

Feasibility of RS-OCT Data Acquisition

0 200 400 600 800 1000 1200 1400 1600 1800 2000600

620

640

660

680

700

720

740

760

Raman Shift (wave numbers 1/cm)

Ram

an In

tens

ity

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8-500

1500

3500

5500

7500

9500

Distance (mm)

Ref

lect

ance

Figure 6: Raman spectrum of Tylenol tablet shown in Figure 3.