Page 1: More Speed, Resolution and Sensitivity in HPLC & LC-MS

More Speed, Resolution and Sensitivity in HPLC & LC-MS

Without Investing in Capital Equipment

Page 2: More Speed, Resolution and Sensitivity in HPLC & LC-MS

2

Overview of Presentation

•HPLC Innovations:• Particle technology• Bonded phase selectivity• Extended pH range

•LC-MS and MALDI-MS:• Chiral LC-MS subject of later presentation• Reducing matrix effects and ion suppression subject of later presentation• Solvents and additives• Ionic liquids

Page 3: More Speed, Resolution and Sensitivity in HPLC & LC-MS

3

HPLC Innovations

• Particle technology - Ascentis® Express with Fused-Core™ particles

• Bonded phase selectivity• Extended pH range

Users are.....• HPLC and LC-MS analysts

Interested in...• Decreasing run time• Increasing resolution• Increasing sensitivity• Using existing HPLC systems

Users are.....• HPLC and LC-MS analysts

Interested in...• Decreasing run time• Increasing resolution• Increasing sensitivity• Using existing HPLC systems

Page 4: More Speed, Resolution and Sensitivity in HPLC & LC-MS

4

Recent HPLC Innovations & the Rationale Behind Them

• HPLC particle manufacturers been focusing their product development on ways to increase sample throughput by decreasing analysis time.

1.0 2.0 3.0 4.0Time (min)

0 2 4 6 8 10 12 14 16 18Time (sec)

4 min. (conventional particles)

30 sec.

16 sec.0 10 20 30

Time (sec)

new technologies

Page 5: More Speed, Resolution and Sensitivity in HPLC & LC-MS

5

Fundamentals: Resolution Equation

• Innovations related to improving resolution and sensitivity leverage one or more variables in the Resolution Equation

• Challenge: How to decrease run time, but maintain your separation (k, α and total N)?

• Conventional approaches (5 and 3 µm particles):1. Decrease column length, but this reduces plates (N L)2. Increase flow rate, but this causes high pressure and reduces N

NR = kk+1

α-1α4

• •

Page 6: More Speed, Resolution and Sensitivity in HPLC & LC-MS

6

Industry Response to HPLC User Needs: Two Particle Innovations

• 2004: UHPLC• In order to achieve faster separations, UHPLC technology was introduced• UHPLC comprises:

• Small particles (sub-2 µm) generate higher N– Smaller particles allow you to maintain the same number of plates required

for a given separation on a shorter column• Instruments that provide the pressure required to drive these separations

– Smaller particles also require pressures that go beyond the capabilities of a conventional HPLC system

• 2007 to today: Fused-Core• A new and proven particle innovation allows the use of columns packed with Fused-Core particles to achieve the same efficiency and speed advantages as UHPLC, but at ½ the pressure, and on conventional instruments.

Page 7: More Speed, Resolution and Sensitivity in HPLC & LC-MS

7

Innovations in Silica Particles Have Boosted Efficiency

• Why the steady trend to smaller particles?• Smaller particles provide higher efficiencies

• However, smaller particles generate higher pressure• Unique particle morphologies with lower pressure are becoming important

1970s 1980s 1990s 2004 2007

10µm 5µm 3µm Sub-2µm

2.7µmFused-Core

Page 8: More Speed, Resolution and Sensitivity in HPLC & LC-MS

8

Fused-Core: A New HPLC Particle Concept

• High-capacity layer of colloidal silica fused to non-permeable silica core.

• Efficiency of sub-2 µm porous particles.

• Low column back-pressures, comparable to 3 µm particles.

• Ruggedness of 5 µm columns; easy to prepare and resistant to blockage (2 µm frits).

• Use either traditional or ultra-HPLC instruments.

• Extend performance of UHPLC to longer columns and get even higher N.

The innovation behind Ascentis Express

Page 9: More Speed, Resolution and Sensitivity in HPLC & LC-MS

9

Fused-Core Particles: Comparison of Morphology to Porous 3 µm Particles

Short diffusion path and uniform particle distribution minimize peak broadening and result in extremely high performance, comparable to sub-2 µm particles, but at much lower pressure. Higher flows and longer columns are possible.

Page 10: More Speed, Resolution and Sensitivity in HPLC & LC-MS

10

Fused-Core Features & Benefits Summary

• Features:1. Unique particle morphology2. ~ 3 µm particle size3. Tight particle size distribution

• Benefits:1. Efficiency equal to sub-2 µm particles2. Maintains efficiency at high flow rates3. One-half the pressure of sub-2 µm particles4. Uses conventional HPLC instruments (e.g. what you currently have)5. Even higher efficiency possible than sub-2 µm particles by using longer

columns

Page 11: More Speed, Resolution and Sensitivity in HPLC & LC-MS

11

2.0 3.0

0

20

40

60

2.0 3.0

0

20

40

60

1.9 2.9 3.

0

19

39

59

1.9 2.9 3.

0

19

39

59

Nave = 36,000P = 285 bar (Fused-Core)P = ~600 bar (sub 2-µm)*

Nave = 18,000P = 250 bar

Nave = 12,000P = 150 bar

Nave = 6,000P = 80 bar

3 µm particles

5 µmparticles

10 µm particles

2.7 µm Fused-Coresub-2 µm*particles

Evolution of Improvement: Efficiency & Pressure vs. Particle

Columns: 15 cm x 4.6 mm I.D., Flow: 1.8 mL/min., Temp.: 30 °C, o- and p-xylene*Estimated P for the sub-2 µm since 15 cm L not supplied

Page 12: More Speed, Resolution and Sensitivity in HPLC & LC-MS

12

Fundamentals: van Deemter Equation

A Term – Particle bed uniformity (how well packed the column is)

B Term – Diffusion along column (how long the zone is on the column)

C Term – Diffusion within particle (rate of mass transfer in/out of pores and phase)

Efficiency in HPLC is described by the van Deemter Equation

(where H is plate height)

H

Average Linear Velocity (v)v = L/t0

H = A + B/u + CuN = L/H

Page 13: More Speed, Resolution and Sensitivity in HPLC & LC-MS

13

• Improves the A-term of the van Deemter equation

• Can use 2 µm frits:• Extremely rugged & resistant to

plugging• Sub-2µm particles typically require

0.2 µm frits

Particle Diameter, µm

Ascentis Express: 2.7 µm +/- 6%

Typical porous silica particle: Average +/- 19%

Benefits of Tight Particle Size Distribution

-500

0

500

1000

1500

2000

2500

3000

1 2 3 4 5 6 7

Num

ber

Page 14: More Speed, Resolution and Sensitivity in HPLC & LC-MS

14 Mobile Phase Velocity (mm/sec)

2 4 6 8 10 12

16,000

14,000

12,000

10,000

8,000

6,000

4,000

2,000

Pre

ssur

e (p

si)

3 µm

1.7 µm

2.7 µm Fused-Core

~ 1 mL/min.

Mobile Phase Velocity (mm/sec)

HE

TP (

m)

16,000

35.00

30.00

25.00

20.00

15.00

10.00

5.002.7 µm Fused-Core

2 4 6 8 10 12

~1 mL/min.

Ascentis Express Column TechnologyFact: Pressure rises faster than efficiency and resolution as particle size is reducedChallenge: Achieve sub-2µm efficiency at 3µm pressures

pdN 1

2

1

pdP

Page 15: More Speed, Resolution and Sensitivity in HPLC & LC-MS

15

Adverse Effect of Pressure: Increase and Non-Uniform Pressure• van`t Hoff relationship• Pressure temperature, higher pressure will lead to higher temperature• Temperature does not affect all analytes equally, so selectivity differences may occur

C18 column, 10 cm x 4.6 mm(45:55) 8.7mM ammonium phosphate, pH 6.5:methanol1.5 mL/min.220nm

Crossover at 45°C

lnk

1/T

Page 16: More Speed, Resolution and Sensitivity in HPLC & LC-MS

16

Ultra-High Efficiencies at 3µmPressures Agilent 1200

Ascentis Express C18, 15 cm x 4.6 mm, 2.7 µmMobile Phase: 40/60 water/ACNFlow: 1.0 mL/min., Detection: 254 nm/10 mm/13 µLInjection: 10 µL in mobile phasePressure: 183 bar (2690 psi)

1. Uracil (T0 marker) 2. Acetophenone Nobs = 33,786 (225K pl/m)3. Benzene Nobs = 31,696 (211K pl/m)4. Toluene Nobs = 30,738 (205K pl/m)Ncol = 36,000 (at optimum velocity with 1µL injection)

0 1 2 3 4 min

4

3

21

With high pressure UHPLC systems:• Either increase linear velocity and go much faster

with minimal or no loss of N.• Or use even longer columns, generate more

plates, and achieve much higher resolution and peak capacity.

Page 17: More Speed, Resolution and Sensitivity in HPLC & LC-MS

17

HETP measured for toluene vs. the superficial velocity of the mobile phase on a C18, 15 cm x 4.6 mm, 2.7 m Ascentis Express column, at a temperature of +35 °C. Uracil was taken as unretained compound, to calculate the column breakthrough time. Elution: 30:70 water:acetonitrile

Van Deemter curve at 35 °Ccolumn USHW001402

0.00

2.00

4.00

6.00

8.00

10.00

12.00

0.00 1.00 2.00 3.00 4.00 5.00 6.00

v (mm/sec)

H (u

m)

Virtually no performance loss at higher flow rates

High Flow Rates Provide Fast Separation with No Loss of Resolution

An H of 4µm equals 250,000

plates per meter.

•Data provided by Prof. Luigi Mondello, U. Messina, Messina, Italy

Page 18: More Speed, Resolution and Sensitivity in HPLC & LC-MS

18

0 2 4 6

0 2 4 6

Ascentis Express C1810 cm x 4.6 mm, 2.7 µmPressure: 248 barN = 21,300

Agilent 1100 (400 bar limit)Mobile Phase: 35:65 ACN/WaterFlow Rate: 1.5 mL/min.Detection: 254 nmInjection: 5 µL

Sub-2 µm C185 cm x 4.6 mm, 1.8 µmPressure: 310 barN = 12,800

Ascentis Express: High Efficiency and Low Pressure on Conventional HPLC Instruments

More efficiency near the practical system limit on conventional instruments (e.g. Agilent 1100)

Ascentis Express permits:• Longer columns for higher N• Higher flow rates for faster runs

Because not at Pmax:• Even more speed possible by

increasing flow rate• Even more efficiency possible by

increasing column length

Increased speed or N not possible on sub-2 µm column due to pressure

Page 19: More Speed, Resolution and Sensitivity in HPLC & LC-MS

19

Reversed‐Phase Sample Loading (Butyl Paraben, k ~ 3)60/40 Methanol/ 20 mM sodium phosphate, pH = 7.040 degrees C., 1.5 ml/min, 4.6 x 50 mm C18 columns

0

2,000

4,000

6,000

8,000

10,000

12,000

0.01 0.1 1 10 100

Micrograms Injected  (in 5uL) 

Theo

retical Plates

Ascentis Express Columns Maintain High Sample Capacity

Fused-Core, 2.7 µm

Porous silica, 3 µmLinear over several orders of magnitude

Page 20: More Speed, Resolution and Sensitivity in HPLC & LC-MS

20

Injection: 1 L of 0.01 mg/mL = 10 ngAll chromatograms same x- and y-scale, 220 nm

2.7 m Ascentis Express

3 m

5 m

Ascentis Express Ultra High Efficiency Also Improves Sensitivity

•Linear range improves at trace levels

Page 21: More Speed, Resolution and Sensitivity in HPLC & LC-MS

21

Scaling Method to Fast LC on Traditional HPLC Systems

1.0 2.0 3.0 4.0Time (min)

0.2 0.4 0.6 0.8 1.0Time (min)

Column: 5 µm C18; 15 cm x 3 mmFlow: 0.4 mL/min. (~1.5 mL total volume per run)

Mobile Phase: 20:80, water : acetonitrileInj: 1.5 µL

Temp: 35° CPressure: 885 psi (61 bar)

N(naphthalene): ~11,000k(naphthalene): 1.78

Column: Ascentis Express C18; 5 cm x 3 mmFlow: 0.6 mL/min. (~0.5 mL total volume per run)

Mobile Phase: 31:69, water:acetonitrileInj: 0.5 µL

Temp: 35° CPressure: 1750 psi (121 bar)

N(naphthalene): ~11,000k(naphthalene): 1.75

At least 4-fold increase in throughput with 3-fold solvent-saving due to short column length.

5µm particle

Ascentis Express

1.5 mL total run volume

0.5 mL total run volume

5 µm C18, 15cm x 3mm ID

Ascentis Express,5cm x 3mm ID

uracil (t0)phenolacetophenonebenzenetoluenenaphthalene

uracil (t0)phenolacetophenonebenzenetoluenenaphthalene

Page 22: More Speed, Resolution and Sensitivity in HPLC & LC-MS

22

0 10 20 30Time (sec)

Virtually No Resolution Loss at 4X Normal Flow Rate: Benefit of Flat van Deemter

Column: Ascentis Express C18; 5 cm x 3 mmFlow: 1.2 mL/min.

Mobile Phase: 31:69, water:acetonitrileInj: 0.5 µL

Temp: 35° CPressure: 3700 psi (255 bar) (consider move to UHPLC)

Rs(phenol/acet.): 3.1

Column: Ascentis Express C18; 5 cm x 3 mmFlow: 2.0 mL/min. (~ 4 times normal flow)

Mobile Phase: 31:69, water:acetonitrileInj: 0.5 µL

Temp: 35° CPressure: 6400 psi (441 bar) (requires UHPLC instrument)

Rs(phenol/acet.): 2.8

0 2 4 6 8 10 12 14 16 18Time (sec)

9-fold increase in throughput comparedto the original method on 5µm particle.

15-fold increase in throughput compared to the original method on 5 µm particle (not

possible with 5 or 3 µm due to loss of N).

10 mm/sec velocity (4 times normal)

Time now in seconds

Time now in seconds

Page 23: More Speed, Resolution and Sensitivity in HPLC & LC-MS

23 * D.N. Mallett (GSK), C. Ramírez-Molina, J. Pharm. Biomed. Anal., 2009, 49(1), 100-107.

Ascentis Express Chosen for High Speed LC-MS DMPK Studies*

• Express columns chosen by GSK group for ruggedness and performance

The authors conclude: “The partially porous stationary phase material has demonstrated equivalent resolving power to sub-2µm materials under the ballistic gradient chromatography conditions employed, and shown to exhibit excellent resilience and performance over the analysis of thousands of protein precipitated plasma extracts, suggesting that this type of column is a valuable tool for pharmaceutical bioanalysts.”

Page 24: More Speed, Resolution and Sensitivity in HPLC & LC-MS

241.0 2.0 3.0

Time (min)

12 3

45

Sample (0.2 µg/mL ea.)1. Mesoridazine2. Doxepin3. Desipramine4. Losartan5. Clomipramine

Ballistic Gradients Possible on Ascentis Express

column:Ascentis Express C18 2 cm x 2.1 mm IDmobile phase A: 10mM ammonium formate pH 4.0mobile phase B: 10mM ammonium formate (95:5 acetonitrile:water) pH 4.3temp.: ambientdet.:ESI+, LC/MS-TOFinjection: 2 µLgradient: time %A %B flow

0 80 20 0.40.1 80 20 0.42 0 100 0.42.5 0 100 0.42.51 80 20 0.63.5 80 20 0.4

Page 25: More Speed, Resolution and Sensitivity in HPLC & LC-MS

25

Human Serum Albumin Tryptic Digest (5 micron vs. Fused-Core)

0 10 20 30 40 50 60Time (min)

Ascentis Express C18

Conventional C18 5µm

column: 15 cm x 4.6 mm I.D.mobile phase A: 100% water with 0.1% TFAmobile phase B: 50:50, ACN:water, with 0.1% TFAflow rate: 1.0 mL/min.; temp: 35 °Cdet: UV at 215 nminjection: 20 µLgradient: 0 to 100 %B in 80 min. (linear), hold for 5 min.

Page 26: More Speed, Resolution and Sensitivity in HPLC & LC-MS

26

Human Serum Albumin Tryptic Digest (exploded view 25-45 min)

30 40Time (min)

Ascentis Express C18

Conventional C18

~ 80 peaks

~ 40 peaks

Page 27: More Speed, Resolution and Sensitivity in HPLC & LC-MS

27

Ascentis Express Columns Installed in Waters Acquity®

Page 28: More Speed, Resolution and Sensitivity in HPLC & LC-MS

28

Ascentis Express Column in Agilent 1200

Page 29: More Speed, Resolution and Sensitivity in HPLC & LC-MS

29

High Performance HPLC Fittings

• Permit use of Ascentis Express on any HPLC or UHPLC system• Work with other manufacturers columns

Page 30: More Speed, Resolution and Sensitivity in HPLC & LC-MS

30

Ascentis Express Benefits

1. The same efficiency as sub-2 µm particles, but ½ the pressure2. The same pressure as 3 µm particles, but twice the efficiency3. Compatible with all HPLC and UHPLC instruments

Benefits over sub-2 µm porous particles: Uses conventional HPLC instruments Lower backpressure Longer columns permit higher efficiency More rugged

Benefits over 3 and 5 µm porous particles: Shorter run times than 5 µm (3xN) and 3 µm (2xN) particles without

sacrificing resolution Shorter columns have same efficiency (N) and reduce solvent consumption Higher resolution than 5 µm and 3 µm columns of same length

Page 31: More Speed, Resolution and Sensitivity in HPLC & LC-MS

31

Ascentis Express Columns

• Phases:• Ascentis Express C18 • Ascentis Express C8• Ascentis Express RP-Amide• Ascentis Express Phenyl-Hexyl• Ascentis Express HILIC

• Dimensions (Columns):• 2.1, 3 & 4.6 mm ID• 2, 3, 5, 7.5, 10 & 15 cm L

• Dimensions (Capillaries):• 75, 100, 200, 300 & 500 µm ID• 5 & 15 cm L

• High performance fittings

http://www.sigma-aldrich.com/express

Page 32: More Speed, Resolution and Sensitivity in HPLC & LC-MS

32

HPLC Innovations

• Particle technology – Ascentis Express• Bonded phase selectivity – Ascentis phases• Extended pH range

Users are...• HPLC and LC-MS analysts

Interested in...• Increasing resolution• Increasing or decreasing retention• Using existing HPLC systems

Users can expect...• Different elution patterns• Optimized retention and resolution• “Greener” mobile phases

Users are...• HPLC and LC-MS analysts

Interested in...• Increasing resolution• Increasing or decreasing retention• Using existing HPLC systems

Users can expect...• Different elution patterns• Optimized retention and resolution• “Greener” mobile phases

Page 33: More Speed, Resolution and Sensitivity in HPLC & LC-MS

33

Ascentis Express RP-Amide

The Power of Stationary Phase Selectivity• Two reversed-phase columns, same MP conditions• Different retention profiles

Ascentis ExpressC18

C18: Too muchresolution and retention

C18: Too littleresolution and retention

Leverage bonded phase chemistry to alter retention

and/or selectivity

Page 34: More Speed, Resolution and Sensitivity in HPLC & LC-MS

34

1.00 1.05 1.10 1.15 1.20 1.250.0

0.5

1.0

1.5

2.0

2.5

3.0

0 5K 10K 15K 20K 25K

0 5 10 15 20 25

N

k

Nk

Res

olut

ion

(R)

* J. H. Zhao and P. W. Carr, Analytical Chemistry, 1999. 71(14), 2623-2632.

Selectivity is Still the Most Powerful Term in the Resolution Equation

Selectivity () has the greatest effect on resolution (R) Its effect is not as limited

as the effect of efficiency (N) and retention (k) Selectivity is altered by: Stationary phase Mobile phase Temperature

NR = kk+1

α-1α4

• •

Page 35: More Speed, Resolution and Sensitivity in HPLC & LC-MS

35

Examples of Selectivity Effect on Elution Profiles in RP Mode

• Different bonded phases give different selectivity under the same conditions

• Affects resolution• Affects quantitation and

sensitivity

column: Ascentis Express phases 10 cm x 3 mm ID

mobile phase A: (65:35) water: acetonitrile flow rate: 0.6 mL/min.pressure: 3000 psi total, 2360 psi column

temp.: 35 °Cdet.: UV, 250 nm

injection: 2 µL

Sample (0.1 mg/mL ea.)1. Oxazepam2. Alprazolam3. Clonazepam4. N-Desmethyldiazepam5. Diazepam

Ascentis Express C18

1

23 4

5

0 2 4 6Time (min)

Ascentis ExpressRP-Amide

12 3

4

5

Ascentis Express Phenyl-Hexyl

1

2 3

4

5

Page 36: More Speed, Resolution and Sensitivity in HPLC & LC-MS

36

Column Selection Guide

Compound Class / Interactions Phasehydrophobic, dispersive C18hydrophobic, dispersive C8acids, phenols, anilines, H-Bond donors RP-Amidehetero aromatic and pi-acceptorsmild pi-acids (electron pair acceptors)

Phenyl

bases, electron- and pi-donors Pentafluorophenylhighly polar Silica, Cyano

Page 37: More Speed, Resolution and Sensitivity in HPLC & LC-MS

37

RP Mode Column Selectivity (Orthogonality) Plots

Compares retention (k) for the same compounds on two column phases. Use variety of

analyte types to get global estimate. Different phases

show lower correlation (widest scatter); defines orthogonality. Same phases show

higher correlation.

C8 vs. C18 Phenyl vs. C18

Amide vs. C18 F5 vs. C18

Page 38: More Speed, Resolution and Sensitivity in HPLC & LC-MS

38

HILIC Mode Column Selectivity

• Benefits of HILIC:• Retention of highly-polar analytes

(e.g. metabolites)• Complementary selectivity to RP-

HPLC (often opposite order)• Increases MS sensitivity• Quick transfer from final steps of

sample prep

• HILIC application areas:• Amino acids• Small, polar acids (metabolomics)• Biogenic amines

– neurotransmitters, food/bev. contaminants

• Organophosphates (pesticides)• Sugars• Drug metabolites and conjugates

Ascentis Express HILIC or C18, 10 cm x 2.1 mm ID, (10:90) 100 mM ammonium formate, pH 3.0:acetonitrile. 0.4 mL/min., 35 °C; UV at 254 nm; 1 μL inj.

1) Acenaphthene

2) Adenosine

3) Cytosine

N

N

N

N

NH2

O

OH OH

OH

N

NH

O

NH2

1 2

HILIC

C181 2

1

2

3

1

2, 3

Page 39: More Speed, Resolution and Sensitivity in HPLC & LC-MS

39

HPLC Bonded Phase Choices• Ascentis® Express (2.7 µm Fused-Core™ particles)

• C18• C8• RP-Amide• Phenyl-Hexyl• HILIC (silica)

• Ascentis® (3, 5 and 10 µm)• C18• C8• RP-Amide• Phenyl• Silica

• Discovery® (3, 5 and 10 m)• HS-F5 (pentafluorophenyl)• Cyano

• SUPELCOSIL®

http://www.sigma-aldrich.com/ascentis

Page 40: More Speed, Resolution and Sensitivity in HPLC & LC-MS

40

HPLC Innovations

• Particle technology – Ascentis Express• Bonded phase selectivity – Ascentis phases• Extended pH range – apHera HPLC Columns

Users are...• HPLC and LC-MS analysts

Interested in...• Using pH to alter resolution or retention• Using existing HPLC systems

Users can expect...• Different elution patterns• Wider pH range• Longer column lifetime

Users are...• HPLC and LC-MS analysts

Interested in...• Using pH to alter resolution or retention• Using existing HPLC systems

Users can expect...• Different elution patterns• Wider pH range• Longer column lifetime

Page 41: More Speed, Resolution and Sensitivity in HPLC & LC-MS

41

High pH RP-HPLC Separations on apHera

• apHera particles• Vinyl alcohol

copolymer• pH 2 – 12• Higher

efficiency than polystyrene particles

• 300 Å• C4, C8, C18,

NH2 bonded phase chemistries

analysis at pH 11}

0 10 20 30

Tricyclic Antidepressants at High pH on apHera C18column: apHera C18, 15 cm x 4.6 mm I.D., 5 µmmobile phase A: 10:90, (0.1M piperidine/HCl, pH 11.1):watermobile phase B: 10:90, (0.1M piperidine/HCl, pH 11.1):acetonitrilemobile phase mixing ratio: A:B = 40:60flow rate: 0.6 mL/min.temp.: 35 °Cdet.: 215 nminjection: 5 µLsample: 50 µ g/L ea. in 50:50,mobile phase A: methanol

1

2

3

4

5

6

7

8

1. Clomipramine2. Amitriptyline3. Imipramine4. Norclomipramine5. Doxepin6. Nortriptyline7. Desipramine8. Nordoxepin

Page 42: More Speed, Resolution and Sensitivity in HPLC & LC-MS

42

2

1

3

5

4

Sugar Analysis on apHera NH2• Higher efficiency and lower bleed than APS-silica

1

2

3

4

5

apHera NH2

NH2-silica

Columns: apHera NH2 or aminopropyl silica, 15 cm x 4.6 mm I.D., 5 µm particles mobile phase: 20:80, water:acetonitrileflow rate: 1.0 mL/min.temp.: 25 °Cdet.: ELSD, 45 °C, 3.5 psi nitrogeninjection: 10 μLsample: 500 μg/mL in 30:70, water:acetonitrile

1. D-(-)-Arabinose2. D-(+)-Xylose3. D-(+)-Mannose4. D-(+)-Galactose5. D-(+)-Glucose

Page 43: More Speed, Resolution and Sensitivity in HPLC & LC-MS

43

apHera Products

• High pH stability• Rugged operation• Phases:

• NH2• C18• C8• C4

• Analytical to preparative dimensions:

• 2 – 28 mm ID• 1 – 30 cm L

http://www.sigma-aldrich.com/aphera

Page 44: More Speed, Resolution and Sensitivity in HPLC & LC-MS

44

LC-MS and MALDI-MS Innovations

• Reducing matrix effects – HybridSPE®-PPT• Chiral LC-MS – Astec CHIROBIOTIC CSPs• Solvents and additives• Ionic liquids for ESI and MALDI

Users are...• LC-MS analysts

Interested in...• Increasing MS sensitivity• Increasing column lifetime

Users can expect...• Reduced phospholipid interferences• Enhanced column lifetime

Users are...• LC-MS analysts

Interested in...• Increasing MS sensitivity• Increasing column lifetime

Users can expect...• Reduced phospholipid interferences• Enhanced column lifetime

Winner of The Scientists’ Choice Award for Best Separations Product in 2008. Awarded at PittCon.

Covered in Talk #2 – “Improved Sensitivity and Higher Throughput inBioanalytical Sample Prep”

Page 45: More Speed, Resolution and Sensitivity in HPLC & LC-MS

45

HybridSPE Particles for Selective Phospholipid Removal

The phosphate groups on the phospholipids are strong Lewis bases (electron donors) and complex with the zirconium atoms on the particle surface

Page 46: More Speed, Resolution and Sensitivity in HPLC & LC-MS

46

Effective Phospholipid Removal Prior to LC-MS

• Almost 100% phospholipids in dog plasma were removed by HybridSPE technique, moderate phospholipids were removed by generic polymeric SPE method, and no phospholipids were removed by traditional PPT.

XIC of +MRM (2 pairs): 184.0/184.0 amu from Sample 2 (090208003) of 090208infu.wiff (Turbo Spray) Max. 1700.0 cps.

0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0274 546 819 1091 1364 1637 1909 2182 2454 2727 3000 3272

Time, min

0.0

5000.0

1.0e4

1.5e4

2.0e4

2.5e4

3.0e4

3.5e4

4.0e4

4.5e4

5.0e4

5.5e4

6.0e4

6.5e4

7.0e4

7.5e4

8.0e4

8.5e4

9.0e4

9.4e4

Intensity, cps

0.720.66 0.80

PPT method

SPE method

HybridSPE method

Phospholipid breakthrough with different sample preparation methods

Page 47: More Speed, Resolution and Sensitivity in HPLC & LC-MS

47

LC-MS and MALDI-MS Innovations

• Reducing matrix effects• Chiral LC-MS – Astec CHIROBIOTIC® CSPs• Solvents and additives• Ionic liquids for ESI and MALDI

Users are...• HPLC and LC-MS analysts• Performing chiral HPLC separations

Interested in...• Analyzing enantiomers by LC-MS

Users can expect...• MS-friendly chiral separations•Flexible MP operations

Users are...• HPLC and LC-MS analysts• Performing chiral HPLC separations

Interested in...• Analyzing enantiomers by LC-MS

Users can expect...• MS-friendly chiral separations•Flexible MP operations

Covered in Talk #3 – “Practicing Chiral Chromatography in Your Mobile Phase Comfort Zone”

Page 48: More Speed, Resolution and Sensitivity in HPLC & LC-MS

48

LC-MS and MALDI-MS Innovations

• Reducing matrix effects – HybridSPE-PPT • Chiral LC-MS – Astec CHIROBIOTIC CSPs• Solvents and additives – LC/MS CHROMASOLV• Ionic liquids for ESI and MALDIUsers are...

• HPLC and LC-MS analysts

Interested in...• Increased sensitivity• Reduced instrument down-time• Reducing MP preparation

Users can expect...• Reduced cluster ion formation• Better sensitivity• Reduce MP prep time

Users are...• HPLC and LC-MS analysts

Interested in...• Increased sensitivity• Reduced instrument down-time• Reducing MP preparation

Users can expect...• Reduced cluster ion formation• Better sensitivity• Reduce MP prep time

Page 49: More Speed, Resolution and Sensitivity in HPLC & LC-MS

49

Cluster Ion Formation in LC-MS

• Mass spectra of human gastrin dissolved in 0.2% formic acid in water at high (left) and low (right) ppm alkali metal concentrations:

• Solvent impurities interfere with LC-MS sensitivity and reliability• Also ideal as mobile phases for low-UV & as sample prep solvents

MS spectra in HPLC-grade solvent MS spectra in LC-MS CHROMASOLV solvent

Page 50: More Speed, Resolution and Sensitivity in HPLC & LC-MS

50

CHROMASOLV Solvents for LC-MS • Extremely high purity• Rigorous test specifications

• Metals, inorganic ions, particles• Over 34 quality tests

• Solvents:• Water, Acetonitrile, Methanol, 2-

Propanol, Ethyl Acetate• Additives:

• TFA, acetic acid, formic acid, propionic acid, ammonium acetate, ammonium formate, TFA, sodium citrate, ammonium hydroxide, ammonium bicarbonate

• Blends:• 0.1% acetic acid, formic acid,

ammonium acetate, TFA and blends • In water, acetonitrile or methanol

http://www.sigma-aldrich.com/chromasolv

Page 51: More Speed, Resolution and Sensitivity in HPLC & LC-MS

51

LC-MS and MALDI-MS Innovations

Users are...• MS (MALDI, ESI) analysts

Interested in...• Increase MS sensitivity

Users can expect...• (+) ESI of anions• Better MALDI fragmentation patterns

Users are...• MS (MALDI, ESI) analysts

Interested in...• Increase MS sensitivity

Users can expect...• (+) ESI of anions• Better MALDI fragmentation patterns

• Chiral LC-MS – Astec CHIROBIOTIC CSPs• Reducing matrix effects – HybridSPE-PPT• Solvents and additives – LC/MS CHROMASOLV• Ionic liquids for ESI and MALDI

Page 52: More Speed, Resolution and Sensitivity in HPLC & LC-MS

52

Ionic Liquids for (+)ESI-MS of Anions (Ion Pairing) – Dication IL

1) Formation of the adduct between dication IL and perchlorate anion.

2) The resulting positive, singly-charged ion can be detected by (+) ESI with very high sensitivity.

1,9-Nonandiyl-bis-(3-methylimidazolium) difluoridem/z = +145.12 Da m/z = -98.95 Da

m/z = +389.19 Da

Page 53: More Speed, Resolution and Sensitivity in HPLC & LC-MS

53

Ionic Liquids for (+)ESI-MS of Anions (Ion Pairing) – Trication IL

1) Formation of the adduct between trication IL and sulfate anion.

2) The resulting positive, singly-charged ion can be detected by (+) ESI with very high sensitivity.

1,3-imidazolium-bis-(1-hexyl-benzyl-imidazolium)-trifluoridem/z = +183.20 Da m/z = -47.97 Da

m/z = +647.34 Da

Page 54: More Speed, Resolution and Sensitivity in HPLC & LC-MS

54

Ionic Liquids for MALDI-MS

•Ionic liquids for MALDI:• Nearly no vapor pressure,

which leads to a better vacuum stability

• Clean spectra, for high resolution

From “Ionic Matrices for MALDI-QIT-ToF-MSn peptide sequencing and MALDI-ToF-MS peptide mass fingerprinting” T. Deierling, et al

QIT-ToF peptide mass fingerprint spectra (stainless steel target)

1: Bradykinin2: Angiotensin II3: Angiotensin I4: Bombesin5: N-acetyl-Renin-substrate6: ACTH, (1-17)7: ACTH (18-39)8: Somatostatin 28M: Matrix

CHCA-B +

CHCA-DE +

Page 55: More Speed, Resolution and Sensitivity in HPLC & LC-MS

55

Ionic Liquids for MALDI-MS• Ionic liquids for MALDI also form uniform coatings on the target.

From “Ionic Matrices for MALDI-QIT-ToF-MSn peptide sequencing and MALDI-ToF-MS peptide mass fingerprinting” T. Deierling, et al

Comparison of crystallization-pattern of DHB (conventional matrix) and CHCA-DE on stainless steel target CHCA-DE

2,5-Dihydroxybenzoic acid (DHB)

Page 56: More Speed, Resolution and Sensitivity in HPLC & LC-MS

56

Ionic Liquids for LC-MS • Ready to use solutions with

complete instructionsESI-MS

• 1,9-Nonandiyl-bis-(3-methylimidazolium) difluoride; 5 mM in methanol:water (1:1) (75128)

• 1,3-imidazolium-bis-(1-hexyl-benzyl-imidazolium)-trifluoride; 5 mM in H2O (08675)

• MALDI-MS• α-Cyano-4-hydroxycinnamic acid

butylamine salt (CHCA-B, 67336) • α-Cyano-4-hydroxycinnamic acid

diethylamine salt (CHCA-DE, 55341)

Page 57: More Speed, Resolution and Sensitivity in HPLC & LC-MS

57

Summary

• HPLC Innovations:• Particle technology – Ascentis® Express with Fused-Core™ Technology • Bonded phase selectivity – Different phase chemistries of Ascentis and

Ascentis Express• Extended pH range – apHera

• LC-MS and MALDI-MS:• Chiral LC-MS – Astec chiral phases• Ion suppression – HybridSPE™-PPT Technology • Solvents and additives – LC-MS CHROMASOLV• Ionic liquids – For MALDI and ESI-MS

Page 58: More Speed, Resolution and Sensitivity in HPLC & LC-MS

58

Acknowledgements/Collaborators

• Prof. Daniel Armstrong, U. Texas Arlington• Prof. Luigi Mondello, U. Messina, Messina, Italy• Jack Kirkland, AMT, Inc.• Dick Henry, Consultant• Supelco and Fluka R&D Teams

For more information on the subjects presented here, please contact [email protected] or

your regional sales team.

Fused-Core is a trademark of Advanced Materials Technologies, Inc. (AMT)Acquity and UPLC are trademarks of Waters Corp.