MONTEROSA HIGH WALL INVERTER R-410A 50HZ HEAT PUMP … · MONTEROSA HIGH WALL INVERTER R-410A 50HZ...

4
MONTEROSA HIGH WALL INVERTER R-410A 50HZ HEAT PUMP YHKE 09 to 24 ZE--MJORX A complete range from 2.6kW to 7.0kW

Transcript of MONTEROSA HIGH WALL INVERTER R-410A 50HZ HEAT PUMP … · MONTEROSA HIGH WALL INVERTER R-410A 50HZ...

Page 1: MONTEROSA HIGH WALL INVERTER R-410A 50HZ HEAT PUMP … · MONTEROSA HIGH WALL INVERTER R-410A 50HZ HEAT PUMP The YORK® line of High Wall Air Conditioners includes a wide range of

MONTEROSA HIGH WALL INVERTER R-410A 50HZ HEAT PUMP

YHKE 09 to 24 ZE--MJORXA complete range from 2.6kW to 7.0kW

Page 2: MONTEROSA HIGH WALL INVERTER R-410A 50HZ HEAT PUMP … · MONTEROSA HIGH WALL INVERTER R-410A 50HZ HEAT PUMP The YORK® line of High Wall Air Conditioners includes a wide range of

2 3

MONTEROSA HIGH WALL INVERTER R-410A 50HZ HEAT PUMP

The YORK® line of High Wall Air Conditioners includes a wide range of sizes to give you more flexibility in your product offering. Each model is designed to provide comfort and efficiency, in an easy-to-operate unit and the sleek design fits a variety of spaces, whether it’s in a home or office. Models meet the highest energy efficiency ratings, so less energy is consumed without sacrificing comfort and performance. Both the condensing and indoor units are engineered for quiet operation. And comfort control settings are easily changed with the touch of a button on the remote control.

Indoor Unit

• Modern, compact design• Efficient cooling/heating• Auto restart• Low/high ambient cooling• Low noise• Hidden display• Follow me• Louver position memory• 3D air flow (Option)• Wired controller (Option)• WIFI (Option)

Remote Control

• 5 operation modes• Sleep mode and on/off timers• Turbo cool/heat settings• Clock display

Condensing Unit

• Fashion appearance• Sturdy and durable• High efficiency DC compressor• Convenient installation• Easy maintenance• Valve protection cover

Page 3: MONTEROSA HIGH WALL INVERTER R-410A 50HZ HEAT PUMP … · MONTEROSA HIGH WALL INVERTER R-410A 50HZ HEAT PUMP The YORK® line of High Wall Air Conditioners includes a wide range of

2 3

MONTEROSA HIGH WALL INVERTER R-410A 50HZ HEAT PUMP

Features and benefits

Multi-Speed FanMulti-speed fan helps satisfy various airflow requirements.

Auto RestartUnit is automatically returned to previous operating conditions after a power outage, for simplified operation.

3-Minute ProtectionA 3-minute delay before the compressor will restart helps avoid compressor damage and work time.

Self DiagnosisClearly displayed failure codes allow for quicker troubleshooting and easier maintenance.

24-Hour TimerAllows programmed start times up to 24 hours in advance for flexible and more convenient operation.

Turbo ModeProvides quicker cooling/heating with one press of the remote button.

Follow MeA temperature sensor embedded in the remote control helps ensure accurate air temperature around the user and not just around the indoor unit, providing maximum comfort.

WIFI Control (Option)Controls air conditioner with Smart phone or tablet through Internet.

DC Inverter CompressorDC inverter compressor provides more comfortable indoor environment, higher performance in partial load and better heating performance in low ambient temperature than fixed compressor.

INVERTER

Refrigerant Leakage Detect

If there is refrigerant system block, leakage, or compressor overload, the indoor unit will display “EC” and stop the unit. It’s easy for after service people to diagnosis the problem and solve it ASAP.

R-410AEnvironmentally-friendly refrigerant cools and heats more efficiently without destroying the ozone layer.

Page 4: MONTEROSA HIGH WALL INVERTER R-410A 50HZ HEAT PUMP … · MONTEROSA HIGH WALL INVERTER R-410A 50HZ HEAT PUMP The YORK® line of High Wall Air Conditioners includes a wide range of

Nominal testing conditions:Cooling - Indoor 80.6°F DB / 66.2°F WB (27°C DB / 19°C WB) & Outdoor 95°F DB / 75.2°F WB (35°C DB / 24°C WB)Heating - Indoor 68°F DB / 59°F WB (20°C DB / 15°C WB) & Outdoor 44.6°F DB / 42.8°F WB (7°C DB / 6°C WB)

Specification

Johnson Controls, the Johnson Controls logo, YORK are registered trademarks of Johnson Controls, Inc in the United States of America and other countries. Other

trademarks used herein may be trademarks or registered trademarks of other companies.

FOR MORE INFORMATION CONTACT JOHNSONCONTROLS.COM

© 2016 Johnson Controls, Inc, P.O. Box 423, Milwarkee, WI 53201, All rights reserved worldwide. SHKEE--MJORX-161216

York Set Model YHKE09ZE--MJORX YHKE12ZE--MJORX YHKE18ZE--MJORX YHKE24ZE--MJORXYork Outdoor YHKE09YE--MJO-X YHKE12YE--MJO-X YHKE18YE--MJO-X YHKE24YE--MJO-XYork Indoor YHKE09XE--MJ-RX YHKE12XE--MJ-RX YHKE18XE--MJ-RX YHKE24XE--MJ-RX

Power supply Ph-V-Hz 1Ph - 220~240V -50Hz

Cooling

Capacity Btu/h 9,000(3,500~11,000) 12,000(3,700-14,000) 18,000(6,200~20,900) 24,000(9,100-26,900)Capacity W 2,638(1,026~3224) 3,517(1,084~4,103) 5,275(1,817~6,125) 7,034(2,667~7,884)Input W 100-1,240 100-1,580 140~2,360 240-3,030Rated current A 0.4-5.4 0.4-6.9 0.6~10.3 1.0-13.2SEER W/W 6.2 6.1 6.4 6.1Energy Efficiency Class A++ A++ A++ A++

Heating

Capacity Btu/h 10,000(2,800-11,500) 13,000(3,000-14,400) 19,000(4,700~23,000) 25,000(5,500-30,000)Capacity W 2,931(821~3,370) 3,810(879~4,220) 5,568(1,377~6,741) 7,327(1,612~8,792)Input W 120-1,200 130-1,510 200~2,410 260-3,140Rated current A 0.5-5.2 0.6-6.6 0.9~10.5 1.1-13.7SCOPAverage W/W 4.0 4.0 4.0 4.0Energy Efficiency Class A+ A+ A+ A+

Max. input consumption W 2,075 2,200 2,550 3,700 Max. current A 9.5 10 11.5 17

Compressor

Type ROTARY ROTARY ROTARY ROTARYCapacity Btu/h 9,010 9,010 13,836 24,345 Input W 671 671 1,035 1,970 Rated current(RLA) A 2.2 2.2 7.32 6.95 Locked rotor Amp(LRA) A 3.5 3.5 ---- ----

Indoor fan motorOutput W 45(Input) 45(Input) 30 58Capacitor μF 1.5 1.5 - - - -Speed(Hi/Mi/Lo) r/min 1,130 / 900 / 800 1,130 / 900 / 800 1,130 / 900 / 800 1,130 / 900 / 800

Indoor air flow (Hi/Mi/Lo) m3/h 420/320/270 570/470/370 840/680/540 980/800/640Indoor sound pressure level (Hi/Mi/Lo/Si) dB(A) 40/34/29.5/25 41/36/28/23 47/40/35/25 45/39/34/27Indoor sound power level (Hi) dB(A) 52 53 56 59

Indoor unitDimension (WxHxD) mm 715x285x194 805x285x194 957x302 x213 1040×327×220Packing (WxHxD) mm 780x360x270 870x360x270 1035x380x295 1120x310x405Net/Gross weight kg 6.8/8.9 7.2/9.6 9.5/12.5 11.9/15.2

Outdoor fan motorOutput W 40 40 40 50Speed r/min 810/710/520 810/710/520 810/700/550 810/750/600

Outdoor air flow m3/h 1,800 1,800 2,100 2,700Outdoor sound pressure level dB(A) 55.5 56 56 60

Outdoor unitDimension(WxHxD) mm 770x555x300 770x555x300 800x554x333 845x702x363Packing (WxHxD) mm 900x585x345 900x585x345 920x615x390 965x755x395Net/Gross weight kg 25.2/27.4 25.5/27.7 37.8/40.5 48.4/51.6

Refrigerant Type R-410A/0.8 R-410A/0.8 R-410A/1.48 R-410A/1.85GWP 2088 2088 2088 2088

Design pressure MPa 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5

Refrigerant pipingLiquid side/ Gas side mm(inch) Ø6.35/Ø9.52(1/4"/3/8") Ø6.35/Ø9.52(1/4"/3/8") Ø6.35/Ø12.7(1/4"/1/2") Ø9.52/Ø15.9(3/8"/5/8")Max. refrigerant pipe length m 25 25 30 50Max. difference in level m 10 10 20 25

Operation temperature

Indoor(cooling/ heating) °C 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 Outdoor(cooling/heating) °C -15~50/-15~30 -15~50/-15~30 -15~50/-15~30 -15~50/-15~30

Application area min/max m2 12/18 16/23 24/36 32/47Qty’per 20’ /40’ /40'HQ 120/250/280 110/230/260 90/186/208 66/140/156