MOMO Hotwire Thermostat - Kevin Byers · MOMO To select Auto use the mode button Press the power...

4
Hotwire Thermostat Instructions Model Number: HWTH1 Australia Verve Distribution 81 Brighton Rd Glenelg SA 5045 www.vervedistribution.com.au New Zealand The Heating Company International PO Box 420 Whitianga NZ www.hotwire.co.nz MO MO

Transcript of MOMO Hotwire Thermostat - Kevin Byers · MOMO To select Auto use the mode button Press the power...

Page 1: MOMO Hotwire Thermostat - Kevin Byers · MOMO To select Auto use the mode button Press the power button to turn on your thermostat. Press the ok button. The reading will return to

Hotwire ThermostatInstructions

Model Number: HWTH1

HotwireThermostatInstructions

Turning your heating Off Manually:

Your thermostat and floor are both off and your floor will cool down. Any

settings you have entered into the Thermostat will be maintained

Australia

Verve Distribution6 Todd StPort Adelaide SA 5015

www.vervedistribution.com.au

New Zealand

The Heating CompanyPO BOX 420 Whitianga NZ

www.hotwire.co.nz

Program button

Confirm button

Set the clock

Set the day of the week

7

8

6

5

4

3

2

1

RT stands for “room temperature” and FT stands for “floor temperature”.

Power button, to turn on/off the thermostat9

Manu

Auto

Indicates the time frames available in Auto Mode.

Heating is turned on

“Manu” indicates manual mode, “Auto” indicates automatic mode. In

Auto mode, the thermostat executes the preprogrammed schedules.

While in Manu mode, the thermostat maintains a constant set temperature

manually set by the user.

Button and Descriptions

RT/FT

1 2 3 4

Press clock button, and time display will start flashing

Use the up and down buttons to adjust .Holding the

Press the OK button once the time is set.

Press the day button to get to the current Day of the week.

Step One: Set The Time and Day:

Turning your heating on and off Automatically

buttons down will increase or decrease the time in 15 minutes increments.

Ensure that the thermostat is on Auto mode.

Step Two: Set the thermostat to Auto mode

Turning your heating On Manually:

Press the up or down button to adjust to the required temperature

Around 23degC is an average but you can increase if required.

Press OK button to exit.

Step Three: Programming your schedulesIf you set your thermostat to 7 day programmable mode

If you set your thermostat to 5+2 day programmable mode

(1). Press Prog button.

(3). Press up or down buttons to adjust the time you wish the program 1 event to commence for the currently selected day. and then press Prog button.

(2). Press up or down buttons to select the day you wish to start programming. then press Prog.(hold up button to select all days of the week, to cancel, hold up button again.)

(4). Press up or down buttons to set the temperature for this time period,then press Prog.

(6). Press OK to save and exit.

(8). Press OK to save and exit.

(5). Set time and temperature for the next time period. Repeat step(2) and (3) for each time period.

(1). Press Prog button.(2). Press up or down buttons to adjust the time you wish the program 1 event to commence for the week days( from Monday to Friday). and then press Prog button.

(5). Press up or down buttons to adjust the time you wish the program 1 event to commence for the weekends( Saturday and Sunday). and then press Prog button.

(3). Press up or down buttons to set the temperature for this time period,then press Prog.(4). Set time and temperature for the next time period. Repeat step(2) and (3) for each time period. and then press Prog button.

(6). Press up or down buttons to set the temperature for this time period,then press Prog.(7). Set time and temperature for the next time period. Repeat step(5) and (6) for each time period.

icon will display.

Key Lock & Unlock

Press and hold to unlock the thermostat. The lock icon will disappear.

* Note no program changes are possible while the unit is locked.

Press and hold to lock the thermostat. A lock

In Auto mode, to temporary override the current setpoint temperature,1. Press up or down button once, the set temperature starts flashing.2. Press up or down button again to adjust the set temperature.3. Press OK button to confirm the setting with OVERRIDE shown.

Now your thermostat will maintain the new set temperature until the next setpoint. To cancel the override setting, press Del button once.

Temporary temperature override

In standby mode(when thermostat is turned off), press and hold Clock button and

Your thermostat has the ability to reset all settings to the factory defaults. If you are certain you want to do this:

Day button for 5 seconds until --:-- is shown(shown for 5 seconds only)

Resetting factory defaults

MOMO

To select Auto use the mode button

Press the power button to turn on your thermostat.

Press the ok button. The reading will return to the ambient temperature

Press Power button to turn off your thermostat, you will see OFF on LCD.

Press the Mode button until the screen shows manual.

Australia

Verve Distribution81 Brighton Rd

Glenelg SA 5045

www.vervedistribution.com.au

New Zealand

The Heating CompanyInternationalPO Box 420

Whitianga NZ

www.hotwire.co.nz

HotwireThermostatInstructions

Turning your heating Off Manually:

Your thermostat and floor are both off and your floor will cool down. Any

settings you have entered into the Thermostat will be maintained

Australia

Verve Distribution6 Todd StPort Adelaide SA 5015

www.vervedistribution.com.au

New Zealand

The Heating CompanyPO BOX 420 Whitianga NZ

www.hotwire.co.nz

Program button

Confirm button

Set the clock

Set the day of the week

7

8

6

5

4

3

2

1

RT stands for “room temperature” and FT stands for “floor temperature”.

Power button, to turn on/off the thermostat9

Manu

Auto

Indicates the time frames available in Auto Mode.

Heating is turned on

“Manu” indicates manual mode, “Auto” indicates automatic mode. In

Auto mode, the thermostat executes the preprogrammed schedules.

While in Manu mode, the thermostat maintains a constant set temperature

manually set by the user.

Button and Descriptions

RT/FT

1 2 3 4

Press clock button, and time display will start flashing

Use the up and down buttons to adjust .Holding the

Press the OK button once the time is set.

Press the day button to get to the current Day of the week.

Step One: Set The Time and Day:

Turning your heating on and off Automatically

buttons down will increase or decrease the time in 15 minutes increments.

Ensure that the thermostat is on Auto mode.

Step Two: Set the thermostat to Auto mode

Turning your heating On Manually:

Press the up or down button to adjust to the required temperature

Around 23degC is an average but you can increase if required.

Press OK button to exit.

Step Three: Programming your schedulesIf you set your thermostat to 7 day programmable mode

If you set your thermostat to 5+2 day programmable mode

(1). Press Prog button.

(3). Press up or down buttons to adjust the time you wish the program 1 event to commence for the currently selected day. and then press Prog button.

(2). Press up or down buttons to select the day you wish to start programming. then press Prog.(hold up button to select all days of the week, to cancel, hold up button again.)

(4). Press up or down buttons to set the temperature for this time period,then press Prog.

(6). Press OK to save and exit.

(8). Press OK to save and exit.

(5). Set time and temperature for the next time period. Repeat step(2) and (3) for each time period.

(1). Press Prog button.(2). Press up or down buttons to adjust the time you wish the program 1 event to commence for the week days( from Monday to Friday). and then press Prog button.

(5). Press up or down buttons to adjust the time you wish the program 1 event to commence for the weekends( Saturday and Sunday). and then press Prog button.

(3). Press up or down buttons to set the temperature for this time period,then press Prog.(4). Set time and temperature for the next time period. Repeat step(2) and (3) for each time period. and then press Prog button.

(6). Press up or down buttons to set the temperature for this time period,then press Prog.(7). Set time and temperature for the next time period. Repeat step(5) and (6) for each time period.

icon will display.

Key Lock & Unlock

Press and hold to unlock the thermostat. The lock icon will disappear.

* Note no program changes are possible while the unit is locked.

Press and hold to lock the thermostat. A lock

In Auto mode, to temporary override the current setpoint temperature,1. Press up or down button once, the set temperature starts flashing.2. Press up or down button again to adjust the set temperature.3. Press OK button to confirm the setting with OVERRIDE shown.

Now your thermostat will maintain the new set temperature until the next setpoint. To cancel the override setting, press Del button once.

Temporary temperature override

In standby mode(when thermostat is turned off), press and hold Clock button and

Your thermostat has the ability to reset all settings to the factory defaults. If you are certain you want to do this:

Day button for 5 seconds until --:-- is shown(shown for 5 seconds only)

Resetting factory defaults

MOMO

To select Auto use the mode button

Press the power button to turn on your thermostat.

Press the ok button. The reading will return to the ambient temperature

Press Power button to turn off your thermostat, you will see OFF on LCD.

Press the Mode button until the screen shows manual.

Page 2: MOMO Hotwire Thermostat - Kevin Byers · MOMO To select Auto use the mode button Press the power button to turn on your thermostat. Press the ok button. The reading will return to

HotwireThermostatInstructions

Turning your heating Off Manually:

Your thermostat and floor are both off and your floor will cool down. Any

settings you have entered into the Thermostat will be maintained

Australia

Verve Distribution6 Todd StPort Adelaide SA 5015

www.vervedistribution.com.au

New Zealand

The Heating CompanyPO BOX 420 Whitianga NZ

www.hotwire.co.nz

Program button

Confirm button

Set the clock

Set the day of the week

7

8

6

5

4

3

2

1

RT stands for “room temperature” and FT stands for “floor temperature”.

Power button, to turn on/off the thermostat9

Manu

Auto

Indicates the time frames available in Auto Mode.

Heating is turned on

“Manu” indicates manual mode, “Auto” indicates automatic mode. In

Auto mode, the thermostat executes the preprogrammed schedules.

While in Manu mode, the thermostat maintains a constant set temperature

manually set by the user.

Button and Descriptions

RT/FT

1 2 3 4

Press clock button, and time display will start flashing

Use the up and down buttons to adjust .Holding the

Press the OK button once the time is set.

Press the day button to get to the current Day of the week.

Step One: Set The Time and Day:

Turning your heating on and off Automatically

buttons down will increase or decrease the time in 15 minutes increments.

Ensure that the thermostat is on Auto mode.

Step Two: Set the thermostat to Auto mode

Turning your heating On Manually:

Press the up or down button to adjust to the required temperature

Around 23degC is an average but you can increase if required.

Press OK button to exit.

Step Three: Programming your schedulesIf you set your thermostat to 7 day programmable mode

If you set your thermostat to 5+2 day programmable mode

(1). Press Prog button.

(3). Press up or down buttons to adjust the time you wish the program 1 event to commence for the currently selected day. and then press Prog button.

(2). Press up or down buttons to select the day you wish to start programming. then press Prog.(hold up button to select all days of the week, to cancel, hold up button again.)

(4). Press up or down buttons to set the temperature for this time period,then press Prog.

(6). Press OK to save and exit.

(8). Press OK to save and exit.

(5). Set time and temperature for the next time period. Repeat step(2) and (3) for each time period.

(1). Press Prog button.(2). Press up or down buttons to adjust the time you wish the program 1 event to commence for the week days( from Monday to Friday). and then press Prog button.

(5). Press up or down buttons to adjust the time you wish the program 1 event to commence for the weekends( Saturday and Sunday). and then press Prog button.

(3). Press up or down buttons to set the temperature for this time period,then press Prog.(4). Set time and temperature for the next time period. Repeat step(2) and (3) for each time period. and then press Prog button.

(6). Press up or down buttons to set the temperature for this time period,then press Prog.(7). Set time and temperature for the next time period. Repeat step(5) and (6) for each time period.

icon will display.

Key Lock & Unlock

Press and hold to unlock the thermostat. The lock icon will disappear.

* Note no program changes are possible while the unit is locked.

Press and hold to lock the thermostat. A lock

In Auto mode, to temporary override the current setpoint temperature,1. Press up or down button once, the set temperature starts flashing.2. Press up or down button again to adjust the set temperature.3. Press OK button to confirm the setting with OVERRIDE shown.

Now your thermostat will maintain the new set temperature until the next setpoint. To cancel the override setting, press Del button once.

Temporary temperature override

In standby mode(when thermostat is turned off), press and hold Clock button and

Your thermostat has the ability to reset all settings to the factory defaults. If you are certain you want to do this:

Day button for 5 seconds until --:-- is shown(shown for 5 seconds only)

Resetting factory defaults

MOMO

To select Auto use the mode button

Press the power button to turn on your thermostat.

Press the ok button. The reading will return to the ambient temperature

Press Power button to turn off your thermostat, you will see OFF on LCD.

Press the Mode button until the screen shows manual.

Delete mistakes during programming.

Up button. Also a long press (5 seconds ) will lock the keypad.

Down button. Also a long press (5 seconds ) will un lock the keypad.

Flame icon should now be shown on screen

Button and DescriptionsProgram button

Delete mistakes during programming.

Select the Automatic or Manual operating mode.

Confirm button

To set the clock. Press the clock button press the up and down buttons

Press to select day of the week. Press repeatedly to select different

days

Up button. Also a long press (5 seconds ) will lock the keypad.

Down button. Also a long press (5 seconds ) will un lock the keypad.

Power button, to turn on/off the thermostat

RT stands for “room temperature” and FT stands for “floor temperature”.

Heating is turned on

“Manu” indicates manual mode, “Auto” indicates automatic mode. In

Auto mode, thermostat executes the preprogrammed schedules.

While in Manu mode, the thermostat maintains a constant set temperature

manually set by the user.

Indicates the time frames available in Auto Mode.

Prog

Del

Mode

Ok

Clock

Day

+

-

RT/FT

Manu

Auto

and then press Ok.

1 2 3 4

Turning your heating on and off Automatically

Step One: Set The Time and Day:(1). Press the clock button and the time display will start flashing, use the up and

down buttons to adjust.

(2). Holding the buttons down will increase or decrease the time in 15 minutes

increments. Press the OK button once the time is set.

(3). Press the day button to get to the current Day of the week.

(4). Press OK button to exit.

Ensure that the thermostat is on Auto mode. To select Auto mode press the Mode

Step Two: Set the thermostat to Auto mode

button until Auto is displayed.Your thermostat has 4 events each day. An Event is

the moment at which the Thermostat will switch the heating on or off. For example

Event 1 is the moment at which your heating will be activated each morning. Event

2 is when it will switch off in the morning. Event 3 is the evening or afternoon

activation, Event 4 is the time in evening or afternoon at which the heating will

switch off.

Step Three: Programming your schedulesTo set your thermostat to 5+2 day programmable mode (Your thermostat will do

the same thing Monday to Friday and can be programmed for different times on

the weekend)

(1). Press Prog button.

(2). Press up or down buttons to adjust the time you wish the Event 1 to com-

mence for the week days( from Monday to Friday). and then press Prog button.

(3). Press up or down buttons to set the temperature for this Event, then press

Prog.

(4). Set time and temperature for the next event. Repeat step(2) and (3) for each

time period. and then press Prog button.

(5). Press up or down buttons to adjust the time you wish Event to commence for

the weekends( Saturday and Sunday). and then press Prog button.

(6). Press up or down buttons to set the temperature for this event, then press

Prog.

(7). Set time and temperature for the next event. Repeat step(5) and (6) for each

event.(8). Press OK to save and exit.

HotwireThermostatInstructionsMenu Settings

Press Power buttton to turn off the thermostat. Press and hold button Prog for 3 seconds to bring up a configuration menu. Now press Prog button to select different menu number.

Set the temperature readout(AF model only). This gives option to choose to show air A= to show air temperature,

A - F = to show both in 5 second intervals temperature,floor temperature or to show both floor & air in interval.

01 = 5+2 day programmable02 = 7 day programmable

LOAD (16A)

FEED230 VAC

Floor Sensor

LL NN Power Supply:

220Vac +10%, 50/60Hz

Load Capability: <16 A, 220VAC

Accuracy: 1deg C

Set-point range: ambient 5~30 deg C

floor 5~40 deg C

Storage: -20~50 deg C

Sensor selection. This thermostat is a combination model allowing you to choosebetween 3 different models. (A, AF,F,)A model: air only , with built in sensor

AF model: air & floor , with both built in and remote sensorF model: floor onl y , with remote sensor

Menu #

1

Switching differential.

Calibrate the room temperature. This feature is used to compensate for any difference

Calibrate the floor temperature. This feature is used to compensate for any difference

Set the floor temperature limit(AF model only).

Select temperature format

Select 12 / 24 hour clock 24 12 / 24

2

3

4

5

6

7

8

9

10

Feature Description Factory DefaultFeature Value

0°C

ON / OFF OFF

01

40

A

°C 20°C ~ 40 °C

°C / °F °C

A / AF / F A

Press up or down button to select

The numbers of degree difference before switching. The default is

between the displayed room temperature and a thermometer.

between the displayed floor temperature and a thermometer.

This feature is to protect the floor surface.

°C or °F.

Program type selection. This gives user 2 options of program type.(5+2 or 7 day programmable) 5+2 day will give you 5 days(Monday to Fiday) with the same four events(Wakeup, out,

7 day will give you individual settings for each day from Monday to Sunday.

home,sleep) and 2 days(Saturday and Sunday) with the same four events.

Frost protection. This feature is to avoid room temperature goes below 5 °C

1°C which means the thermostat will switch the heating on 0.5°C below the set temperature and will turn it off 0.5°C above the set temperature. With a 2°C differential, the heating will switch on 1°C below the set temperature and will switch off 1°C above the set temperature.

1°C 1°C ~ 5°C

-5°C ~ +5°C

0°C -5°C ~ +5°C

F=to show floor temperature,

To set your thermostat to 7 day programmable mode use the following steps

(1). Press Prog button.

(2). Press up or down buttons to select the day you wish to start programming.

Or hold up button to select all seven days of the week. Then press Prog. (to

cancel all seven days programming hold up button down) Time will start

flashing.

(3). Press up or down buttons to adjust the time you wish Event 1 to commence

for the currently selected day. and then press Prog button, Temperature will

start flashing.

(4). Press up or down buttons to set the temperature for this time period,then press

Prog.

(5). Set time and temperature for the next event. Repeat step(2) and (3) for each

event.

(6). Press OK to save and exit.

(Your thermostat will do the same thing for all seven days of the week)

Page 3: MOMO Hotwire Thermostat - Kevin Byers · MOMO To select Auto use the mode button Press the power button to turn on your thermostat. Press the ok button. The reading will return to

HotwireThermostatInstructionsMenu Settings

Press Power buttton to turn off the thermostat. Press and hold button Prog for 3 seconds to bring up a configuration menu. Now press Prog button to select different menu number.

Set the temperature readout(AF model only). This gives option to choose to show air A= to show air temperature,

A - F = to show both in 5 second intervals temperature,floor temperature or to show both floor & air in interval.

01 = 5+2 day programmable02 = 7 day programmable

LOAD (16A)

FEED230 VAC

Floor Sensor

LL NN Power Supply:

220Vac +10%, 50/60Hz

Load Capability: <16 A, 220VAC

Accuracy: 1deg C

Set-point range: ambient 5~30 deg C

floor 5~40 deg C

Storage: -20~50 deg C

Sensor selection. This thermostat is a combination model allowing you to choosebetween 3 different models. (A, AF,F,)A model: air only , with built in sensor

AF model: air & floor , with both built in and remote sensorF model: floor onl y , with remote sensor

Menu #

1

Switching differential.

Calibrate the room temperature. This feature is used to compensate for any difference

Calibrate the floor temperature. This feature is used to compensate for any difference

Set the floor temperature limit(AF model only).

Select temperature format

Select 12 / 24 hour clock 24 12 / 24

2

3

4

5

6

7

8

9

10

Feature Description Factory DefaultFeature Value

0°C

ON / OFF OFF

01

40

A

°C 20°C ~ 40 °C

°C / °F °C

A / AF / F A

Press up or down button to select

The numbers of degree difference before switching. The default is

between the displayed room temperature and a thermometer.

between the displayed floor temperature and a thermometer.

This feature is to protect the floor surface.

°C or °F.

Program type selection. This gives user 2 options of program type.(5+2 or 7 day programmable) 5+2 day will give you 5 days(Monday to Fiday) with the same four events(Wakeup, out,

7 day will give you individual settings for each day from Monday to Sunday.

home,sleep) and 2 days(Saturday and Sunday) with the same four events.

Frost protection. This feature is to avoid room temperature goes below 5 °C

1°C which means the thermostat will switch the heating on 0.5°C below the set temperature and will turn it off 0.5°C above the set temperature. With a 2°C differential, the heating will switch on 1°C below the set temperature and will switch off 1°C above the set temperature.

1°C 1°C ~ 5°C

-5°C ~ +5°C

0°C -5°C ~ +5°C

F=to show floor temperature,

HotwireThermostatInstructionsMenu Settings

Press Power buttton to turn off the thermostat. Press and hold button Prog for 3 seconds to bring up a configuration menu. Now press Prog button to select different menu number.

Set the temperature readout(AF model only). This gives option to choose to show air A= to show air temperature,

A - F = to show both in 5 second intervals temperature,floor temperature or to show both floor & air in interval.

01 = 5+2 day programmable02 = 7 day programmable

LOAD (16A)

FEED230 VAC

Floor Sensor

LL NN Power Supply:

220Vac +10%, 50/60Hz

Load Capability: <16 A, 220VAC

Accuracy: 1deg C

Set-point range: ambient 5~30 deg C

floor 5~40 deg C

Storage: -20~50 deg C

Sensor selection. This thermostat is a combination model allowing you to choosebetween 3 different models. (A, AF,F,)A model: air only , with built in sensor

AF model: air & floor , with both built in and remote sensorF model: floor onl y , with remote sensor

Menu #

1

Switching differential.

Calibrate the room temperature. This feature is used to compensate for any difference

Calibrate the floor temperature. This feature is used to compensate for any difference

Set the floor temperature limit(AF model only).

Select temperature format

Select 12 / 24 hour clock 24 12 / 24

2

3

4

5

6

7

8

9

10

Feature Description Factory DefaultFeature Value

0°C

ON / OFF OFF

01

40

A

°C 20°C ~ 40 °C

°C / °F °C

A / AF / F A

Press up or down button to select

The numbers of degree difference before switching. The default is

between the displayed room temperature and a thermometer.

between the displayed floor temperature and a thermometer.

This feature is to protect the floor surface.

°C or °F.

Program type selection. This gives user 2 options of program type.(5+2 or 7 day programmable) 5+2 day will give you 5 days(Monday to Fiday) with the same four events(Wakeup, out,

7 day will give you individual settings for each day from Monday to Sunday.

home,sleep) and 2 days(Saturday and Sunday) with the same four events.

Frost protection. This feature is to avoid room temperature goes below 5 °C

1°C which means the thermostat will switch the heating on 0.5°C below the set temperature and will turn it off 0.5°C above the set temperature. With a 2°C differential, the heating will switch on 1°C below the set temperature and will switch off 1°C above the set temperature.

1°C 1°C ~ 5°C

-5°C ~ +5°C

0°C -5°C ~ +5°C

F=to show floor temperature,

In Auto mode, to temporarily override the current setpoint temperature,

1. Press up or down button once, the set temperature starts flashing.

2. Press up or down button again to adjust the set temperature.

3. Press OK button to confirm the setting with OVERRIDE shown.

Now your thermostat will maintain the new set temperature until the next setpoint.

To cancel the override setting, press Del button once.

Temporary temperature override

Press and hold up button to lock the thermostat. A lock icon will display.

Key Lock & Unlock

Press and hold down button to unlock the thermostat. The unlock icon will dissapear.

Your thermostat has the ability to reset all settings to the factory defaults. In standby

mode(when thermostat is turned off), press and hold Clock button and

Day button for 5 seconds until --:-- is shown(shown for 5 seconds only)

* Note no program changes are possible while the unit is locked.

Resetting factory defaults

Defaults are as follows:

Event 1 7:00 am

Event 2 9:30 am

Event 3 4:30 pm

Event 4 10:30 pm

Installation Instructions

Using a screwdriver unscrew the front plate from the back plate. Then pull

the bottom of the thermostat towards you off the back plate. Wire up the

thermostat as per the wiring diagram below, then place the back plate into the flush

box and tighten it with the screws provided. To replace the thermostat put the top

into the backing plate and then push the bottom of the thermostat in. Then replace

screw holding both parts together.

Blue

wire

from

ele

men

t

Brow

n w

ire fr

om e

lem

ent

Line

from

sw

itch

box

230/240 VAC

Connect green wire from theelement to the house earth

(Cables can go either side)

Hous

e Ne

utra

l

Page 4: MOMO Hotwire Thermostat - Kevin Byers · MOMO To select Auto use the mode button Press the power button to turn on your thermostat. Press the ok button. The reading will return to

Menu # Feature ExplanationFactory default

Adjustment(Press up & down buttons to adjust)

01 Mode/Sensor Selection

This thermostat is a combination model whichallows you to choose 3 different modes

A mode = Air Sensing Only (Has built in sensor)AF mode = Air & Floor sensing

F mode = Floor sensing ( floor probe installed)

A A / AF / F

02 Switching differential

The number of degrees difference before switchingThe default is 1Deg C which means the stat will

switch the heating on 0.5DegC below the set temperature and will turn it off 0.5DegC above the

set temperature.With a 2 DegC differential the heating will switch

on 1 DegC below the set temperature and will switch off 1 DegC above the set temperature.

1 DegC 1 Deg C - 5 Deg C

03 Air Temp Calibration This is to recalibrate the air temp if required 0DegC -5 Deg C - + 5 Deg C

04 Floor Temp Calibration This is the recalibrate the floor temperature if req 0DegC - 5 Deg C - + 5 Deg C

05Temp Readout (AF mode only)

This gives you the option to show the Air Temp,floor Temp or to show both Air & Floor at intervals

A

A = Show Air TemperatureF = Show Floor Temperature

A-F = Show Floor and Air Temperature in 5 sec intervals

06Maximum Floor Temp

( AF Mode only)This is to protect the floor surface 40 DegC 20 Deg C - 40 Deg C

07Temperature For-

matThis allows the temperature to be set to show

Deg Celsius or Deg FahrenheitC Deg C / Deg F

08 Clock FormatYou can select the clock to show in either 12

or 24 hour time24 12 / 24

09 Frost Protection This is to avoid your room temp going below 5 DegC Off On / Off

10 5+2 or 7 Day mode This allows you to program either 5 days at once,

then the 2 days of the weekend separately, or a full 7 days at the same time.

01 01 = 5 + 2 Day Programming02 = 7 Day Programming

Hotwire ThermostatTechnical Information

To access Menu settings,

1. Press Power button to turn off the thermostat.

2. Press and hold button Prog for three seconds to bring up the configuration menu. Now press Prog button to select each different menu number.

Menu Settings

Page 2

Press , starts flashing, press or to adjust the setpoint among a range of 5~30 deg C. (for floor mode, the

range will be 5~40 deg C). Press to confirm.

Press and hold to lock the buttons. A lock icon will display.

Vacation mode is used to drop the heating down to a minimum set temperature to ensure room stays damp free.

Press and hold to unlock the buttons. The unlock icon will display.

220Vac 10%, 50/60HzDC 3 V (2 x 1.5 V AAA Alkaline batteries)

Accuracy: ±1

Set-point range: ambient 5~30 deg C floor 5~40 deg C

Storage: -20~50 deg C

Load Capability: <16 A, 220VAC

deg C

Wiring Diagram & Technical Specifications

Additional Functions

+230V AC

heating element

Floor Sensor

Probe N L M

This product should be installed by a qualified electrician.

Press this tab lightly back and simultaneously push the front panel upward to release it off the back plate. Wire up the Thermostat as per the wiring diagram below, then place theback into the flushbox, and tighten it with the screws provided.To replace the Thermostat, slide the front panel downwardonto the back plate.

Vacation Mode Adjustment

Key Lock & Unlock

Dimensions & Installation

Power Supply:

96 26.7

88.260

6

102240

58

119

122.

4

113.

685 10

10

95

51

110