ANSI-IsA-S7.0.01-1996_Quality Standard for Instrument Air_S_7001
Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample...
Transcript of Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample...
![Page 1: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/1.jpg)
![Page 2: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/2.jpg)
Modular (ANSI/ISA-76 NeSSI) Sample Systems:
Parts to Performance in 45 MinutesIFPAC - 2006 CPAC – 2006
Twentieth International Forum Center forProcess Analytical Chemistry Process Analytical(Process Analysis & Control) Chemistry
February 20-23, 2006 May 8-11, 2006Arlington, VA Seattle, WA
Robert E. Sherman CIRCOR Techa division of CIRCOR Instrumentation Technologies
![Page 3: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/3.jpg)
Legacy Sample Systems
• Pipe and TEFLON tape• Tubing and ---lok Fittings• Brackets and Braces• Discrete Components• Analog Signals• Multi-wire Systems
![Page 4: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/4.jpg)
Modular Sample Systems
• ANSI/ISA-76– Defines hardware
• NeSSI (CPAC)– Defines Systems– Defines (??) Communications
![Page 5: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/5.jpg)
Modular Hardware
• Uniform Base Dimensions– 1.50 x 1.50 – inches
• Interchangeable between Manufacturers
![Page 6: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/6.jpg)
Modular Systems
• “Lego”-like Construction• “Habitrail”-like Sample Transport• Half-or-Less Footprint (cf. Legacy)• Components are Totally Interchangeable
![Page 7: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/7.jpg)
Modular Communications
• Buss Structure– Standard “in process”
• Wireless– Standard “in future”
![Page 8: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/8.jpg)
UOP Project Observations (actual)
• UOP Des Plaines, IL Michelle Cohn• LAMIMS Gas Handling System (CPAC Spring 2004)
• Construction and Demonstration Accelerated with NeSSI• Resources W/NeSSI Typical • Elapsed time 4months 6 months • Personnel time 2months 4months • Manifold cost +10% Baseline
![Page 9: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/9.jpg)
ISA EXPO2005 Chicago, IL
• International Student Games• Practical Exercise• Teams of 3 or 4 College Students• Junior or Senior Class Standing• Engineering or Chemistry Curriculum
![Page 10: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/10.jpg)
Drawings Provided to Student Teams
• Schematic of Flow• Manifolds – Top (plan) View• Manifolds – Bottom (plan) View• Manifold 1 – Side (section/elevation) View• Manifold 2 – Side (section/elevation) View
![Page 11: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/11.jpg)
Bill of Material (BOM) Provided
• Summarizing (BOM is on Drawing 1 of 5)• 4 Support Feet• 7 Surface Mount Components• 11 Transfer Tubes (Tubesets)• 32 Component Attachment SHC Screws• 36 O-ring Seals• 52 Base Block Assembly Screws
![Page 12: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/12.jpg)
Modular Flow Schematic
![Page 13: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/13.jpg)
Modular Manifolds-Top (plan) View
![Page 14: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/14.jpg)
![Page 15: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/15.jpg)
Modular Manifolds-Bottom (plan) View
![Page 16: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/16.jpg)
![Page 17: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/17.jpg)
•
![Page 18: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/18.jpg)
Modular Manifold 1Side (section/elevation) View
![Page 19: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/19.jpg)
![Page 20: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/20.jpg)
Modular Manifold 2Side (section/elevation) View
![Page 21: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/21.jpg)
![Page 22: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/22.jpg)
![Page 23: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/23.jpg)
![Page 24: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/24.jpg)
![Page 25: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/25.jpg)
![Page 26: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/26.jpg)
![Page 27: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/27.jpg)
![Page 28: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/28.jpg)
![Page 29: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/29.jpg)
SP76-based Analytical
Spectrophotometer CellUV / NIR (fiberoptic)Corner-cube ReflectorsApplied Analytics Inc.
Analyzer-on-a-BlockUV/VIS/NDIRProprietaryUnder Development
![Page 30: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/30.jpg)
ANSI/ISA-76 Compliant!FM Global Approved!ANSI/ISAANSI/ISA--76 Compliant!76 Compliant!FM Global Approved!FM Global Approved!
Smallest ANSI/ISA-76 Mass Flow Controller/Meter
HORIBA STEC:
SEC-G111/SEF-G111 Series
![Page 31: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/31.jpg)
SP76-based Filters (typical)
• A+ Corporation (LA, USA)Avenger (bypass and particulate)Genie (cylindrical format membrane separator)
• Classic (UK)Primary (particulate)Secondary (polishing)CoalescingLiquid Discriminating (TFE membrane)
![Page 32: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/32.jpg)
SP76-based FlowmetersRotameters(light duty-right side& armored-left side)
Brooks / Emerson (both)
Bühler / Buehler (light)
King (light)
Krohne (both)
![Page 33: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/33.jpg)
Air Dimensions ANSI/ISA-76 Pump
![Page 34: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/34.jpg)
SP76-basedSwitches, Sensors and Gauges
Switches-FlowChem-Tec Eqpt. Co.Delta MFCIMalema
Switches-Moisture/Water Bühler / Buehler
Sensors-P, F(Q), THoneywell
GaugesBourdon
![Page 35: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/35.jpg)
SP76-based Valves (typical)CIRCOR Tech
Diaphragm Valvesmanual actuated
(on-off)pneumatic* actuated
( I/P actuator available ‘soon’;electric operator ‘soon’)
‘Application Module Family’3-wayDouble Block-and-Bleed (DBB)Atmospheric Reference-and-Vent
( NO and NC versions )
2-way and 3-way ball
*Positive Position Indication optional
![Page 36: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/36.jpg)
CIRCOR Tech Experts and Expertise
Bruce Keen1972 to currentSample Conditioning
Design ExperienceFON: 918.336.4369FAX: 918.338.2238EML:[email protected] Vos UK/EU/Near [email protected]
Bob Sherman1969 to currentAnalytical System
Application ExperienceFON: 815.931.9087FAX: 815.744.7271EML: [email protected] Dorfman Asia/Pac [email protected]
![Page 37: Modular (ANSI/ISA-76 NeSSI) - University of Washington · Modular (ANSI/ISA-76 NeSSI) Sample Systems: Parts to Performance in 45 Minutes IFPAC - 2006 CPAC –2006 Twentieth International](https://reader030.fdocuments.in/reader030/viewer/2022033123/5e83d4a440f50419ef7abb99/html5/thumbnails/37.jpg)
Thank you and…‘Sample’ our
W O R L D - - - - W I D Eexpertise
…at CIRCOR Tech !