Modeling of Fiber Reinforced Polymer confined concrete ...

112
Louisiana State University LSU Digital Commons LSU Master's eses Graduate School 2006 Modeling of Fiber Reinforced Polymer confined concrete cylinders Indrani V. Volety Louisiana State University and Agricultural and Mechanical College, [email protected] Follow this and additional works at: hps://digitalcommons.lsu.edu/gradschool_theses Part of the Mechanical Engineering Commons is esis is brought to you for free and open access by the Graduate School at LSU Digital Commons. It has been accepted for inclusion in LSU Master's eses by an authorized graduate school editor of LSU Digital Commons. For more information, please contact [email protected]. Recommended Citation Volety, Indrani V., "Modeling of Fiber Reinforced Polymer confined concrete cylinders" (2006). LSU Master's eses. 3658. hps://digitalcommons.lsu.edu/gradschool_theses/3658

Transcript of Modeling of Fiber Reinforced Polymer confined concrete ...

Page 1: Modeling of Fiber Reinforced Polymer confined concrete ...

Louisiana State UniversityLSU Digital Commons

LSU Master's Theses Graduate School

2006

Modeling of Fiber Reinforced Polymer confinedconcrete cylindersIndrani V. VoletyLouisiana State University and Agricultural and Mechanical College, [email protected]

Follow this and additional works at: https://digitalcommons.lsu.edu/gradschool_theses

Part of the Mechanical Engineering Commons

This Thesis is brought to you for free and open access by the Graduate School at LSU Digital Commons. It has been accepted for inclusion in LSUMaster's Theses by an authorized graduate school editor of LSU Digital Commons. For more information, please contact [email protected].

Recommended CitationVolety, Indrani V., "Modeling of Fiber Reinforced Polymer confined concrete cylinders" (2006). LSU Master's Theses. 3658.https://digitalcommons.lsu.edu/gradschool_theses/3658

Page 2: Modeling of Fiber Reinforced Polymer confined concrete ...

MODELING OF FIBER REINFORCED POLYMER CONFINED CONCRETE CYLINDERS

A Thesis

Submitted to the Graduate Faculty of the Louisiana State University and

Agricultural and Mechanical College in partial fulfillment of the

requirements for the degree of Master of Science in Mechanical Engineering

in

Department of Mechanical Engineering

By Indrani Venkata Volety

B.E., Chaitanya Bharathi Institute of Technology, India, 2003 May, 2006

Page 3: Modeling of Fiber Reinforced Polymer confined concrete ...

ACKNOWLEDGEMENTS I would like to express my sincere appreciation and thanks to my advisors and major professors,

Dr. Guoqiang Li and Dr. Yitshak Ram, for their constant guidance and valuable comments. Their

constant encouragement and discussions have helped me gain deep insight in this work. The

completion of this thesis cannot be imagined without their help.

I also express my gratitude to Dr. Su-Seng Pang and Dr. Muhammad Wahab for serving

in my defense committee and providing me with their valuable comments to improve the

contents of this thesis.

I would like to thank my parents and my sister, who have been a constant source of

inspiration, encouragement and support through out my academic pursuit.

A simple “thank you” is not enough for my colleagues - Dr. Jaeho Shim, Dr. Kumar

Vikram Singh, Srinivas Gopal Krishna, Jayaram Subramanian, Dinesh Maricherla, Jerry Alan

Peck and Eashwer Sethuraman – who have contributed in numerous ways to make my program a

pleasant one.

Finally, I would like to thank all my friends especially my roommates here at LSU,

whose company and friendship I dearly cherish. Thank you for making my stay here at LSU a

memorable one.

ii

Page 4: Modeling of Fiber Reinforced Polymer confined concrete ...

TABLE OF CONTENTS ACKNOWLEDGEMENTS.....................................................................................................…...ii

LIST OF TABLES ...……………………………………………………………………………...v

LIST OF FIGURES...…………………………………………………………………………….vi

NOMENCLATURE…………………………………………………………………………….viii

ABSTRACT……………………………………………………………………………………….x

1 INTRODUCTION........................................................................................................................1 1.1 Introduction……………………………………………………………………………1 1.2 FRP Confinement of Concrete………………………………………………………...2 1.3 Problem Statement…………………………………………………………………….2 1.4 Research Objectives…………………………………………………………………...3 1.5 Research Approach……………………………………………………………………4 1.6 Organization of the Thesis…………………………………………………………….5 2 LITERATURE REVIEW...……………………………………………………………………..7 2.1 Introduction……………………………………………………………………………7 2.2 Confinement Models…………………………………………………………………..7 2.3 Summary of the Confinement Models……………………………………………….11 2.4 Conclusions…………………………………………………………………………..12 3 3-D FEM MODELING OF FRP CONFINED CONCRETE COLUMNS AND ITS VALIDATION…………………………………………………………………………………13 3.1 Introduction…………………………………………………………………………..13 3.2 Finite Element Analysis……………………………………………………………...13

3.2.1. Element Formulation…………………………………………………...…15 3.2.1.1. FRP Composites………………………………………………...15 3.2.1.2. Reinforced Concrete ……………………………………………15

3.2.2. Material Properties………………………………………………………..15 3.2.2.1. FRP Composites…………………………………………….......15 3.2.2.2. Concrete…………………………………………………………18

3.2.3. Calculations………………………………………………………………..18 3.2.3.1. Properties of Composite…………………………………………18 3.2.3.2. Properties of Concrete……………………..…………………….20

3.2.4. Modeling and Meshing……………………………………………………20 3.2.5. Boundary Conditions and Loading………………………………………..21 3.2.6. Simulation…………………………………………………………………22 3.2.7. Solution……………………………………………………………………23

3.3. Validation of the Model……………………………………………………………..23 3.4. Conclusions………………………………………………………………………….28

iii

Page 5: Modeling of Fiber Reinforced Polymer confined concrete ...

4 PRACTICAL BOUNDS AND BENCHMARK ANALYTICAL SOLUTIONS FOR CONFIRMATION OF FE MODEL…………………………..……………………………….29 4.1 Introduction…………………………………………………………………………..29 4.2 Practical Bounds……………………………………………………………………...29 4.2.1. Assumptions……………………………………………………………….32 4.3 Analytical Solution for Column Loaded by Transverse Load………………….........38 4.4 Conclusions…………………………………………………………………………..43 5 CRITICAL PARAMETERS IDENTIFICATION AND EVALUATION…………………….44 5.1 Introduction…………………………………………………………………………..44 5.2 Identity Design Parameters and Their Range …………………………………….….44 5.2.1 Effect of FRP Wall Thickness ………………………………….……….…45 5.2.2 Effect of Hoop Tensile Strength of the Composite…………………….…..46

5.2.3 Effect of Unconfined Concrete Strength ……………………………….….47 5.2.4 Effect of Modulus of Elasticity of the Composite……………………….....48

5.3 Conclusions………………………………………………………………………..….48 6 A NOVEL APPROACH FOR A DESIGN-ORIENTED CONFINEMENT MODEL….....….50 6.1 Introduction…………………………………………………………………………..50 6.2 Proposed Confinement Model………………………………………………………..50 6.2.1. Generation of Models ……….………………………………………….…50 6.2.2. Mathematical Model…………………………………………………….…51 6.3. Illustration of the Proposed Confinement Model……………………………………54 6.4 Comparisons and Limitations of the Confinement Model……………………….......55 6.4.1 Limitations…………………………………………………………………56 6.5. Conclusions………………………………………………………………………….57 7 CONCLUSIONS AND FUTURE WORK….…………………………………………………58 7.1 Future Studies………………………………………………………………………..59 REFERENCES…………………………………………………………………………………..60 APPENDIX A: BOUNDARY CONDITIONS…………….………………………………...….64 APPENDIX B: TEST DATABASE……………………………………………………………..80 APPENDIX C: PSEUDO INVERSE METHOD…………………………………………...…..100 VITA………………………………………………………………………………………….....101

iv

Page 6: Modeling of Fiber Reinforced Polymer confined concrete ...

LIST OF TABLES 3.1. Summary of material properties of the FRP for one set of specimens from the experiment results considered…………………………………………………………………………...24 3.2 Comparison of Experimental Results and FEA results………………………………………26

4.1 Transformation matrix……………………………………………………………………….38

5.1. Summary of the various design parameters and their respective ranges……………………45

6.1. Summary of the ranges of the parameters……………………………………………….…..51

6.2 Summary of the models within the considered range…………………………….……….…55

6.3 Comparison of the predictions of cc and k ………………………………………………..56f

v

Page 7: Modeling of Fiber Reinforced Polymer confined concrete ...

LIST OF FIGURES 1.1 Stress-Strain Response of FRP Confined Concrete…………………………………………..3

1.2 Confining action of the composite……………………………………...…………………….4

3.1 SOLID 46 Element Geometry and Coordinate system ……………………………………...16

3.2 SOLID 65 Element Geometry and Coordinate System…………………………………..….16

3.3 Principal directions of an orthotropic material……………………………………………....17

3.4 Principal directions of a unidirectional FRP composite……………………………………..17

3.5 Finite Element Model of FRP jacketed Concrete…………………………………………....21

3.6 Loading and Boundary Conditions on an FRP jacketed concrete column……………….….22

3.7 Cracking and Crushing in Concrete………………………………………………………….24

4.1 Unloaded concrete columns…………………………………………………………………30

4.2 FRP wrap of thickness t

.3 Free body diagram of the FRP element………………………………

……………………………………………………………………..32

4 ……………………...33

4.4 Concrete slab…………………………………………………………………………………35

4.5 Variation of ( )rθσ /p and ip /p with respect to thickness t ……………………………….....36

( )rθσ4.6 Variation of /p and i /p with respect to thickness t ………………………………….37p

4.7 Variation of ( )rθσ /p and i /p with respect to thickness t ………………………………….37p 4.8 Concrete subjected to a transverse load P ………………………………………………......38

4.9 Boundary conditions at ( )0=z …………………………………………………………..….40

4.10 Boundary conditions on the surface ( )lz = …………………………………….……….…41

rface4.11 Boundary conditions on the lateral su of the cylinder Rr =at ……………………..42

5.1 Effect of thickness on the confinement effectiveness coeffic nt ………………………ie ….46

vi

Page 8: Modeling of Fiber Reinforced Polymer confined concrete ...

vii

5.2 Effect of hoop tensile strength on the confinement effectiveness…………….…………….47

5.3 Effect of unconfined concrete strength on the confinement effectiveness………………..…48

5.4 Effect of modulus of the composite on the confinement effectiveness………………….…..49

6.1 Variation of the predicted values from the expression with actual ‘k’ values from the

FEA results…………………………………………………………………………………53

Page 9: Modeling of Fiber Reinforced Polymer confined concrete ...

NOMENCLATURE

- Confined concrete strength

- Unconfined concrete strength

ccf

cf

- Ultimate concrete strain ccε

lf - Confining pressure

- Diameter of the concrete column

- Thickness of the FRP com

- Transverse Young’s modulus

- Hoop tensile strength of FRP composite frpf

d t posite

1E - Longitudinal Young’s modulus

E2

12υ - Major Poisson’s ratio

- In plane shear modulus

- Young’s modulus of concrete

12G

Ec

cυ - Poisson’s ratio of concrete

r - Modulus of Rupture of concrete/ ultimate tensile strength of concretef

te

h - Height of the column

frp -Modulus of the FRP composiE l - Length of the concrete slab b - Breadth of the concrete slab

viii

Page 10: Modeling of Fiber Reinforced Polymer confined concrete ...

h - Height of the concrete slab r - Radius of the concrete column

cl - Length of the concrete column p - Pressure exerted by the slab on the each column

F - Force exerted by the slab ρ - Density of the concrete g - Acceleration due to gravity

or

- Outer radius of the column

ip - Internal pressure in the column u

- Radial displacement

ξ - Radial coordinate

rσ - Radial stress

- External pressure

op

θσ - Tangential stress / hoop stress P - Transverse load

- Confinement effectiveness coefficient

k

c

cc

ff

- Confinement effectiveness/ strengthening ratio

c

l

ff

- Confinement ratio

ix

Page 11: Modeling of Fiber Reinforced Polymer confined concrete ...

ABSTRACT

Fiber Reinforced Polymer (FRP) confined concrete columns have been developed for new

construction and rebuilding of concrete piers/piles in engineering structures. Design of these FRP

confined concrete columns requires an accurate estimate of the performance enhancement due to

the confinement mechanism. Therefore, the key is to develop a confinement model, a model that

relates the confined concrete strength with the unconfined concrete strength and the confining

pressure provided by the FRP. Due to its closed-form expression and ease of application, design-

oriented confinement models predominate in designing FRP confined concrete columns. Design

oriented models are directly based on the interpretation of experimental results. Each existing

design oriented model is based on a certain range of test database and is accurate in predicting

the results within its respective considered range. All the models are based on limited database.

In the present research, an attempt was made to expand the test database with larger

range. A 3-D finite element model of FRP confined concrete column was developed using

ANSYS and was validated by published experimental results available in the literature. Based on

the FEA results, a test data base was developed taking into account all the possible ranges of the

design parameters which affect the confined concrete strength. Analyses of the test database

revealed that the confinement effectiveness depends on thickness, hoop tensile strength, modulus

of elasticity of the FRP and unconfined concrete strength and behaves nonlinearly with each of

them. Therefore, in the present study the main emphasis was to explore a possible approach for a

design oriented confinement model which considers this nonlinear relation between the

confinement effectiveness and the design parameters.

x

Page 12: Modeling of Fiber Reinforced Polymer confined concrete ...

1. INTRODUCTION

1.1. Introduction The advent of the Fiber Reinforced Polymer (FRP) composites in the field of construction and

structural applications was in the early 1940’s. The earliest FRP materials used glass fibers

which were embedded in polymeric resins. The combination of high strength, high stiffness

structural fibers with low cost, light weight and environment resistant polymers have resulted in

composites which have better mechanical properties than any of their constituents. Fiber

materials with higher strength, higher stiffness and lower density, such as boron, carbon, and

aramid, have been commercialized to meet the higher performance challenges around 1960’s and

1970’s (3). FRP being highly expensive has previously restricted their application to aerospace

and defense purposes alone. But, the increase in demand for the utilization of FRP in other fields

around the world has aided the growth in research for better performance composites at

minimized costs.

Highly aggressive environmental conditions have a significant effect on the durability

and structural integrity of steel reinforced concrete piles/piers/columns. Corrosion of steel rods is

a potential cause for the structural damage of these reinforced concrete columns. Tackling the

problem of steel reinforcement corrosion has usually meant improving the quality of the concrete

itself, but this approach has had only limited success. A traditional way of repair of damaged

concrete columns is wrapping a sheet of steel around the column. While the strength of repaired

columns can be increased for a short-term, the steel wrapping suffers from the same problem as

the steel rebar, corrosion and poor durability. It also suffers from labour-intensive construction

problem due to its weight. In a new approach, FRPs are now being used as alternatives for steel

wrappings in repair, rehabilitation and strengthening of reinforced concrete columns. In addition

1

Page 13: Modeling of Fiber Reinforced Polymer confined concrete ...

to repair, FRP confined concrete columns have been developed in new construction and

rebuilding of concrete piers/piles in engineering structures. In this structure, the steel rebar is

replaced by a laminated FRP tube. The FRP tube serves as a stay-in-place formwork during

construction and a confinement device during service. The mechanism of FRP confinement is

explained in the following section.

1.2. FRP Confinement of Concrete

In FRP confined concrete the concrete core expands laterally when it is subjected to an axial

compression load. This expansion of the concrete core is confined by the FRP jackets or shells,

and thus transforms the concrete core to a 3-D compressive stress condition. The 3-D

compressive stress condition serves to significantly increase the compressive strength and the

ductility of brittle concrete. Compared with other cylindrical columns, FRP confined concrete

columns behave uniquely when subjected to an axial compression load. The FRP begins to

confine the concrete shortly after the unconfined concrete strength is reached. It then reverses the

direction of the volumetric response, and the concrete responds through large and stable volume

contraction. As a result, the stress-strain curve is characterized by a distinct bilinear response

with a transition zone at a stress level near the strength of unconfined concrete. Figure1.1. shows

the axial stress-strain behavior of the FRP-confined concrete.

1.3. Problem Statement

A key issue in design for FRP confined concrete column is to develop a confinement model, a

model that relates the confined concrete strength with the unconfined concrete strength and the

confining pressure provided by the FRP. Various researchers have developed different stress-

strain models for FRP confined concrete columns. These models are usually divided into two

categories: (a) Design Oriented Models and (b) Analysis Oriented Models (15). Design oriented

models are closed-form equations and are directly based on the interpretation of experimental

2

Page 14: Modeling of Fiber Reinforced Polymer confined concrete ...

FRP confined concretecf

ccf

ccε

Plain Concrete

Stress

Strain

FRP confined concretecfcf

ccf

ccε ccε

Plain Concrete

Stress

Strain

Figure 1.1 Stress-Strain Response of FRP Confined Concrete.

results. Analysis oriented models, on the other hand, are generated using an incremental

numerical procedure by considering radial strain compatibility. Owing to its closed-form

equation and ease to use, many design-orientated confinement models have been developed by

different researchers such as Fardis and Khalili (7), Samaan and Mirmiran (40), Xiao and Wu (50).

Since each model is developed based on a particular set of experimental results, it was found that

the models based on curve-fitting are successful only for limited cases. Li et al. (17) have shown

the significant deviation among the existing design-oriented confinement models. This deviation

hinders design engineers from the application of these models as generic models. Obviously, a

possible way to overcome the existing problem is to extend the database of test results such that

the data covers a larger range. And based on the analyses and evaluation of the database, a

confinement model can be proposed.

1.4. Research Objectives

In the present work, the following objectives were identified and fulfilled:

1) To expand the test database which covers a larger range of design parameters which

affect the confined concrete strength.

2) To develop, a 3-D finite element model for FRP tube encased concrete cylinders, by

3

Page 15: Modeling of Fiber Reinforced Polymer confined concrete ...

Figure 1.2 Confining action of the composite

considering all the material properties of the FRP and the concrete.

3) ANSYS FEM software was used to develop the model and to perform the required

analysis. The modeling results were compared and validated using the experimental

results available in the literature.

4) A test database was developed by implementing the validated FEM model. The database

was analyzed and critical parameters affecting the performance of the confined column

were identified.

5) An attempt was made to explore a possible approach for developing a confinement model

based on the analyses of the test database.

6) Analytical solutions for limiting cases of FRP confined concrete were also developed.

1.5. Research Approach

In this work, a 3-D finite element model was created using ANSYS. Data from different

published experimental results were collected and the developed 3-D model was validated by

using those results. An analytical solution was developed and the reliability of the developed

4

Page 16: Modeling of Fiber Reinforced Polymer confined concrete ...

model was checked. Different ranges of design parameters affecting the confined concrete

strength were considered. A test database was created with combinations of these parameters.

The test database was analyzed and critical parameters affecting the confinement effectiveness

were identified. The critical parameters were recognized as thickness, hoop tensile strength,

modulus of the composite and unconfined concrete strength. Based on the analyses of the test

data, the confinement effectiveness was considered to be dependent on these critical parameters.

An approach to develop a confinement model was proposed taking into account the nonlinear

behavior of the confinement effectiveness with the critical parameters. Limitations for the

present approach were also evaluated.

1.6. Organization of the Thesis

The first chapter is an introduction, detailing the background and development of the FRP with

the identification of the research problem. It also gives a brief description of the research

objectives and the approach to the solution of the problem. The second chapter is a literature

review in which previous studies and research on the FRP confined concrete have been

reviewed. An understanding of the problem and importance of the research have also been

explored. In the third chapter, a finite element model of the FRP confined concrete was built and

published experimental results of different researchers and research groups have used to validate

the developed model. The fourth chapter gives analytical solutions of limiting cases of the FRP

confined concrete columns, which can be used as bounds of the stress and displacement fields of

the FRP confined concrete columns. This chapter clearly explains the fundamental principles

involved in the problem. In chapter five, a test database was created with combinations of

different parameters like hoop tensile strength, unconfined concrete strength etc. Analyzing the

test database resulted in identifying and evaluating the critical parameters affecting the

confinement effectiveness. Chapter six discusses the approach followed to develop a

5

Page 17: Modeling of Fiber Reinforced Polymer confined concrete ...

confinement model in which the confinement effectiveness coefficient is taken as a function of

the critical parameters evaluated. Conclusions and Future work are discussed in Chapter seven,

followed by a list of references and appendices.

6

Page 18: Modeling of Fiber Reinforced Polymer confined concrete ...

2. LITERATURE REVIEW

2.1. Introduction Fiber reinforced polymer (FRP) confined concrete column shows a unique bilinear behavior

when subjected to an axial compressive load. The stress-strain plot reveals that FRP confines the

concrete shortly after the concrete has reached its ultimate compressive strength. To better

understand the FRP confinement of the concrete a proper stress-strain model has to be

developed. Exclusive work has been done in understanding this behavior.

2.2. Confinement Models

Richart (35), Newman and Newman (30), Mander (22) have developed stress-strain models to

predict the ultimate strength and strain of the confined concrete. These models were developed

for steel tube confined concrete columns and were extended to FRP confinement. These models

were based on ultimate strength of the concrete. They predict the enhancement of the confined

concrete as a function of the confining pressure. Fardis and Khalili (7) reviewed the empirical

formula by Richart (35) to quantify the increase in the concrete compressive strength and the

nonlinear expression by Newman and Newman (30) to obtain an equation to predict the confined

concrete strength by substituting the maximum confining pressure that FRP can exert. It was

found that these steel-based confinement models over estimated the effectiveness of the

confining pressure.

Nanni and Bradford (28) conducted experiments on 150 x 300 mm cylinders which were

confined laterally, spirally with different FRP composites. Stress-strain curves were plotted for

all the specimens individually. It was observed that the confined concrete with FRP, enhanced

strength and pseudo-ductility of the concrete. A comparison of the prediction by two existing

models Mander et al. (22), Fardis et al. (7) was conducted. The models proved to be sufficiently

accurate for prediction of the strength, but underestimated the ultimate strain of concrete

7

Page 19: Modeling of Fiber Reinforced Polymer confined concrete ...

confined with FRP materials. It was also observed that the passive FRP confinement did not

prove advantageous under load conditions below the unconfined concrete strength. Mirmiran (23)

developed a concrete filled hollow FRP composite column which was similar to the classic

concrete filled steel tubes. Behavior of the model was proposed by developing a new passive

confinement model for externally reinforced concrete columns with a composite action model

that evaluates the lateral stiffening effect of the jacket. The studies concluded that the degree of

composite action was appropriately defined as a function of bond strength of the material.

Karbhari and Gao (14) also developed experimental data based on variety of reinforcing fiber

types, orientations and jacket thickness. They developed and verified simple design equations to

estimate the response of composite confined concrete. The authors concluded that development

of a true composite model rather than empirical models which include effects of both the fiber

reinforced composite and the concrete on a true material basis was required. Their proposed

model attempted to address the deficiencies, from the aspect of composite materials modeling,

but fell short of modeling the true response of the composite that changes as the stress level

increases. Including their model, most of the models developed before did not consider the

increase in the Poisson’s ratio of concrete in a highly confined state. This effect is important

since it effects the interactions with the response of the composite confining jacket.

The load and deformation plots from the experimental results of Howie and Karbhari (12)

were found to be bilinear. The initial linear region has a slope similar to that of the unwrapped

cylinder. The slope of the second linear region was substantially less than the initial linear

region. The transition area between the two different slopes was termed as a kink point. It was

observed that the second linear region terminates when the cylinder failed. Continuing the

research in modeling a confinement model for confined concrete, Samaan and Mirmiran (40)

proposed a simple model to predict the bilinear response of the FRP confined concrete in both

8

Page 20: Modeling of Fiber Reinforced Polymer confined concrete ...

axial and lateral directions. The model was based on correlation between the dilation rate of

concrete and the hoop stiffness of the restraining member. The parameters of the model were

directly related to the material properties of the FRP shell and concrete core. Samaan’s model

proved that the existing models failed to predict the behavior of FRP-confined concrete, mainly

because they ignored the stiffness of the restraining mechanism. Test results indicated a bilinear

response in which the initial softening or yielding occurs at the level of the unconfined strength

of concrete and the secondary slope is then proportional to the stiffness of the confining jacket.

Studies performed on short concrete columns encased with FRP composite tubes by

Saafi and Tountaji (38) indicate that the confinement method can be effective in increasing the

strength, ductility and energy absorption capacity of concrete columns. The studies concluded

that the FRP tube composites are an effective means of confinement, significantly increasing

both the strength and ductility of concrete. The rate of increase is dependent on the tube

thickness and the mechanical properties of the composite tube and the unconfined concrete. The

stress-strain response of FRP tube confined concrete was bilinear in both the axial and lateral

direction. The first slope of the response depends on the concrete core, while the stiffness of the

FRP tube controls the second slope. It was shown that the bent point between the slopes takes

place at stress levels slightly higher than the unconfined strength of the concrete core. The

equations developed underestimated the axial strain and overestimate the axial compressive

strength. The proposed equations to estimate the ultimate stresses and failure strains produced

satisfactory predictions when compared to current design equations available. The effect of

lateral strain was also considered in the proposed equations. The predicted stress-strain response

in both the axial and lateral directions of concrete filled FRP tubes compares satisfactorily with

the experimental values. However the model underestimates the results of concrete columns

confined with FRP composite sheets. Xiao and Wu (50) performed experiments and studied the

9

Page 21: Modeling of Fiber Reinforced Polymer confined concrete ...

compressive behavior of concrete confined by carbon fiber composite jackets. They proposed a

bilinear axial stress-strain relationship with the expressions calibrated empirically on

experimental results obtained by the authors. A uniaxial model for concrete confined with FRP

was developed by Spoelstra and Monti (43). They also considered with steel jacketing

(conventional transverse reinforcement). The basis of the model was on the unconfined concrete

model by Popovics (33), which explicitly accounted for the continuous interaction with the

confining device due to lateral strain of concrete, through an incremental iterative approach. For

FRP confined concrete, the resulting stress-strain curves showed gradually increasing behavior

until the FRP jacket failure. The simulated compressive response of normal strength concrete

confined with FRP were compared to available tests on wrapped cylinders, showing agreement

both in terms of stress-strains behavior and ultimate state.

In their research Lam and Teng (15) divided the stress –strain models into two categories

1) Design Oriented models 2) Analysis Oriented models. The Design Oriented Models

considered solution based on closed form equations for predicting stress-strain relations, where

as in the Analysis Oriented Models the stress-strain curves were obtained by numerical

procedure. In analysis oriented model, an active confinement model was considered to predict

the stresses and strains of the confined concrete. From the above confinement models, the

models by Fardis and Khalili (7), Karbhari and Gao (14), Samaan and Mirmiran (40), Saafi and

Tountaji (38), Xiao and Wu (50) were the design oriented models, whereas the models by Mirmiran

and Shahawy (23), Spoelstra and Monti (43) and Fam and Rizkalla (6) were defined as the analytical

models. More recently, Moran and Pantelides (27) developed a stress-strain model using the

Richard and Abbott (34) bilinear model. Their model was based on two concepts which were,

increase in plastic compressive strength of FRP-confined concrete and the kinematic restraint

provided by the FRP jacket and a variable strain ductility ratio in which the increase in plastic

10

Page 22: Modeling of Fiber Reinforced Polymer confined concrete ...

compressive strain as a function of the stiffness of the FRP composite jacket, the type of bond

between the FRP composite and the concrete core and the extent of internal damage in concrete

core.

2.3. Summary of the Confinement Models

Initial studies, to understand the behavior of the FRP confined concrete were, by extension of

steel based confinement models. These models were based on the ultimate strength of the

specimen modeled on triaxial tests. The enhancement of the confined concrete was defined as a

function of confining pressure, which was considered to be constant through the test. But, studies

have shown that for FRP confined concrete, steel based confinement models cannot be applied,

as steel and FRP behave differently under axial loading. Due to the orthotropic material

properties and non yielding behavior of FRP, it exerts a continuously increasing pressure on the

concrete core. The implementation of the models by Mander (22), Richart (35), and Newman and

Newman (30) was proved inappropriate; few confinement models developed were still based on

these models like the Tountaji (45) and Sadaamantesh (39). Confinement and experimental results

from Mirmiran and Shahawy (23) and Spoelstra and Monti (43) proved the inappropriate

implementation of the steel confinement models; they also proved that application of Popovics

equation for complete axial stress-strain curve was also inappropriate. Few models like Samaan

and Mirmiran (40), Saafi and Tountaji (38), and Xiao and Wu (50) used best fit of the experimental

results to correlate the stress-strain behavior of the confined concrete. Most of the models

resulted in either overestimating or underestimating the ultimate strength and strain of the FRP

confined concrete. The results from the models considered above show a bilinear nature of FRP

confined concrete. The predicted equations for the confinement model were dependent on bond

strength of the concrete, confining pressure exerted on concrete. Unconfined concrete strength

also has a significant effect on the predicting equations.

11

Page 23: Modeling of Fiber Reinforced Polymer confined concrete ...

2.4. Conclusions From the above discussion and the previous studies, it is important to note that the behavior of

FRP confined concrete not only depends on the mechanical properties of the FRP and the

unconfined concrete, but also on other parameters like the fiber types, orientation and thickness

of the composite. Therefore, to develop a proper confinement model, it is required to consider all

the above parameters. In the present research, an FEA model was created and was validated with

the existing experimental results from different research groups. A test database was created,

based on variety of thickness, unconfined concrete strength and material properties of the

composite, which are discussed in the following chapters.

12

Page 24: Modeling of Fiber Reinforced Polymer confined concrete ...

3. 3-D FEM MODELING OF FRP CONFINED CONCRETE COLUMN AND ITS VALIDATION

3.1 Introduction In order to understand the behavior of confined concrete wrapped with FRP, the mechanical

properties have to be studied. Designing FRP confined concrete requires analytical tools that

predict the level of performance enhancement for the concrete core. Therefore, a confinement

model - a model predicting the strength and ductility has to be developed. A number of studies

were conducted to evaluate the confinement effectiveness of FRP, taking into account the

mechanism of fiber composites as well as the 3-D stresses in concrete core. Confinement of

columns is a three –dimensional phenomenon that cannot be easily reduced to two-dimensions.

When studying the ductility of confined and unconfined normal and high strength concrete

columns, it is important to accurately incorporate the behavior of concrete. This factor is

important as the concrete shows unique dilation characteristics when confined with linear-elastic

and non-yielding materials such as FRP. For obtaining accurate results, a Finite Element Method

can be approached.

3.2. Finite Element Analysis

Finite element method (FEM) is a powerful tool to effectively simulate the behavior of the FRP

confined concrete columns. Previously, Fardis (7) proposed a hyperbolic function for concrete

cylinders wrapped with bi-directional FRP sheet under uniaxial loading. Circumferential

stiffness was used to describe the enhancement in the performance of the confined columns.

Nanni and Bradford (28) further developed the confinement model. Their model predicted the

strength reasonably well but underestimated the ductility of the fiber wrapped columns. Ahmad

et al. (1) studied the effectiveness of glass FRP and the spiral steel confinement. A confinement

model was developed to predict the confinement effectiveness of the fiberglass spirals which was

13

Page 25: Modeling of Fiber Reinforced Polymer confined concrete ...

used as transverse reinforcement for the concrete columns. Samaan (40) used a bilinear stress-

strain curve and incorporates stiffness of the jacket in calculating lateral strains. This is the

general model considered which worked well for concentrically loaded columns. Rochette and

Labossiere (36) used an incremental finite element technique to evaluate the response of fiber –

wrapped concrete columns. They used Drucker - Prager failure criteria. But the model worked

favorably with their respective uniaxial compression tests. Spoelstra and Monti (43) also

developed a uniaxial concrete model which accounts for the continuous interaction of the

concrete with the confining FRP. The model can be used for concrete confined with either steel

or FRP. The model implements an iterative procedure through which the stress-strain curve

obtained crosses a family of stress-strain curves at constant confinement pressure, where at each

point the confinement pressure is equal to that induced by the FRP jacket subjected to the

corresponding lateral expansion. Mirmiran (26) developed a nonlinear finite element model for

confined concrete using non-associative Drucker – Prager plasticity model. The developed finite

element model used one quarter model of the circular and the square specimen. The non-

associative Drucker – Prager plasticity takes in to account the pressure sensitivity of the material.

The other parameters used for the model are the cohesion, angle of internal friction and the

dilatancy angle. The model was developed in ANSYS. The results show that the Drucker –

Prager plasticity effectively predicts the axial stress-strain response of the FRP confined

columns.

These models show that when a proper numerical model is used Finite element models

can effectively predict the behavior of the FRP confined concrete columns. FEA results can be

confirmed and validated by the previously available experimental results. Based on the FEA

results, the stress-strain behavior of the columns can be analyzed. This analysis gives a better

theoretical understanding and helps in achieving an accurate confinement model.

14

Page 26: Modeling of Fiber Reinforced Polymer confined concrete ...

In this present chapter, a finite element model of FRP confined concrete column was developed

and validated by existing experimental results. The models were simulated using ANSYS 10.0

finite element software. In general, the conclusions and methods would be very similar using

other non linear FEA programs. However, each program has its own nomenclature and

specialized and analysis procedures that need to be properly incorporated in it. The formulation

of the FE model is discussed in the following sections.

3.2.1. Element Formulation

3.2.1.1. FRP Composites

In this present research, a 3-D layered structural element SOLID 46 was used to model FRP

composites. The element allows up to 250 layers. The element has three degrees of freedom at

each node: translation in zyx ,, directions. The element is defined by eight nodes, layer

thickness, layer material direction angles and orthotropic material properties. The geometry and

coordinate system is shown in the Figure 3.1

3.2.1.2. Reinforced Concrete

For the modeling of concrete, a 3-D reinforced concrete solid element SOLID 65 was used. It

can be used with or without reinforcing bars. The solid is capable of cracking in tension and

crushing in compression. The element is defined by eight nodes having three degrees of freedom

at each node: translations in zy x ,, directions. The element has eight nodes and the isotropic

material properties. The geometry and coordinate system is shown in the Figure 3.2.

3.2.2. Material Properties

3.2.2.1. FRP Composites

As defined by the element the input data used are the number of layers, thickness of the layers,

orientation of fiber direction for each layer. The composites are orthotropic materials therefore;

15

Page 27: Modeling of Fiber Reinforced Polymer confined concrete ...

Figure 3.1 SOLID 46 Element Geometry and Coordinate system (ANSYS (2) version 10.0)

Figure 3.2 SOLID 65 Element Geometry and Coordinate System (ANSYS (2) version 10.0)

16

Page 28: Modeling of Fiber Reinforced Polymer confined concrete ...

nine different properties have to be input, the elastic modulus in three different directions

( ), the shear modulus in the three directions ( zxyzxy GG ,, ) and the Poisson’s ratio

in the three zxyzxy

zyx EEE ,, G

directions ( υυυ ,, ). Figure 3.3 gives the principal directions of the orthotropic

aterial.

ibers. The principal directions of this unidirectional

RP composite can be seen in figure 3.4.

Figure 3.4 Principal directions of a unidirectional FRP composite

m

Figure 3.3 Principal directions of an orthotropic material

In the present research, the orientation of the fibers is along the hoop ( 00 ) direction. Therefore,

they are considered as the unidirectional f

F

17

Page 29: Modeling of Fiber Reinforced Polymer confined concrete ...

The material properties determined depending upon the principal directions of the FRP

composite. To determine the failure in the FRP composite, a failure criterion has to be specified.

For, the present model, Tsai-Wu failure criteria was used to check the failure in the FRP. The

details of the failure criterion are given the following sections.

3.2.2.2. Concrete

Isotropic material properties, the elastic modulus ( E and the Poisson’s ratio (x ) xyυ ) are input to

the element, along with the values of ultimate tensile strength ( rf ), ultimate compressive

strength ( c ). The calculated values of different material data is also required by ANSYS. The

calculations are given in the following section.

f

3.2.3. Calculations

The material properties of the FRP composites are calculated using micro mechanics approach.

The principal directions of the FRP composite are shown in figure 3.4.The equations used for the

analysis are given below [see [4] pg.149-193]

3.2.3.1. Properties of the Composite

1EEx = , y = z2EE , = , 3EE

12υυ =xy , 23υυ =yz , 31υυ =zx ,.

= , = .

12GGxy = , yz x23GG 31GGz

From Rule of Mixtures

mmff VEVEE +=1 (3.1)

mffm

mf

VEVEEE

E+

=2 (3.2)

Where = Modulus of elasticity of the Fiber, = Modulus of elasticity of the Matrix fE mE

18

Page 30: Modeling of Fiber Reinforced Polymer confined concrete ...

f = Volume fraction of fiber and m = Volume fraction of matrixV V

Similarly the shear modulus can be calculated

mffm

fmGG=

VGVGG

+12 (3.3)

isson’s ratio is ca

mG = shear modulus of matrix, fG = shear modulus of fiber

Following the same procedure the major Po lculated

mmff VV υυυ += '12 (3.4)

Where fυ = Poisson’s ratio of fiber, mυ = Poisson’s ratio of matrix

The relation between the major Poisson’s ratio and the minor Poisson’s ratio can be given by the

following equation.

2

21

1

12

EEυυ

= (3.5)

The failure in the FRP was verified using Tsai-Wu failu tates ilure in the

re criteria. It s that the fa

FRP occurs when the following equation is satisfied [see [4], pg:259-261]

1=+ jiijii FF σσσ (3.6)

Where the ’s are the strength parameters. These parameters are obtained from simple uniaxial

tests and can be expressed as

6,...2,1, =ji

F

ct XXF 11

1 − , =ct XX

F 111 = (3.7)

ct YYF 1

2 −= , 1

ctYYF22 = (3.8) 1

2661F = (3.LTS

9)

19

Page 31: Modeling of Fiber Reinforced Polymer confined concrete ...

c , are the tensile ant XX , d compressive strength of the FRP in longitudinal ( X ) direction.

ssive strength of the FRP in transverse ( ) direction. And

[see [42], pg: 5-6]

ct YY , , are the tensile and compre Y

LTS , the shear strength.

3.2.3.2. Properties of Concrete

The properties of the concrete are taken from

Modulus of Elasticity [ cE ] psi

psifE cc 57000= (3.10)

Where f = Compressive strength (psi) c

Poisons’ ratio [ ] 2.0=cυ cυ

Modulus of Rupture [ rf ] psi, (Ultimate tensile strength)

psiff cr 5.7= (3.11)

3.2.4. Modeling and Meshing

A cylindrical coordinate system was created at the active working plane. A hollow cylinder was

generated with the given thickness, diameter and height dimensions. A solid cylinder was also

generated with the considered specifications. In this model, the hollow cylinder resembles the

FRP composite and the solid cylinder represents the concrete. The two volumes were glued

together, assuming a perfect bonding between the composite and the concrete. For the validation

of the model, the dimensions used were the dimensions of the coupons and specimen used in the

experiments. For the test database, the dimensions of the cylinder were the standard diameter 152

mm and height 305 mm. The generated model was meshed using mapped mesh which helps in

controlling the number of elements. The fewer the number of elements, the coarse, the mesh is.

Refinement of the mesh increases the accuracy of the simulation also increasing the analysis

20

Page 32: Modeling of Fiber Reinforced Polymer confined concrete ...

time. The mesh size would vary with the dimension of the model. Element attributes were

assigned to the respective elements. The hollow cylinder was meshed with SOLID46 and the

lid cylinder with SOLD65 elements. The coordinate axes of all the elements of hollow cylinder

are oriented to the cylindrical coordinate system. Figure 3.5 shows the finite element model of

the FRP confined concrete.

so

Figure 3.5 Finite Element Model of FRP Confined Concrete

3.2.5. Boundary Conditions and Loading

In the model, the Z-axis of the coordinate system coincides with the axis of the cylinder. The X

and Y axis represent the radial and hoop directions of the cylinder respectively. The boundary

conditions are: 1) one end of the surface was fixed i.e. all the six degrees of freedom on that

21

Page 33: Modeling of Fiber Reinforced Polymer confined concrete ...

surface were constrained. 2) An axial compressive pressure load was applied on the other

surface. The axial pressure load was increased gradually until the FRP fails. This type of loading

ondition and boundary constraints are similar to cylinders under uniaxial compression test.

Figure 3.6 demonstrates the loading and boundary conditions for an FRP jacketed concrete

olumn

c

c .

Figure 3.6 Loading and Boundary Conditions on an FRP jacketed concrete column 3.2.6. Simulation A nonlinear structural analysis was performed, to include the nonlinear material behavior of

concrete and FRP. ANSYS employs the "Newton-Raphson" approach to solve nonlinear

22

Page 34: Modeling of Fiber Reinforced Polymer confined concrete ...

problems. In this approach, the load is subdivided into a series of load increments. The load

increments can be applied over several load steps. This follows an iterative procedure until the

problem converges. A number of convergence enhancement features are allowed in ANSYS like

automatic load stepping, bisection etc can be activated to help the problem to converge. In the

d stepping feature was activated. Automatic load stepping allows

When a FRP wrapped concrete column is subjected to a compressive load, concrete will be the

initial load bearing member of the structure. The compressive load causes micro-cracks in the

concrete. The concrete crushes when its ultimate compressive strength is reached. ANSYS can

show the cracking and crushing of the concrete for an applied load. Figure 3.7 shows the

concrete crushing and cracking; the octagons represent crushing and the circles represent the

cracking in the concrete. The FRP starts confining the concrete column, when the concrete

reaches its ultimate compressive strength. Thus the FRP and the concrete core will carry the load

collaboratively. The failure in the structure occurs when the FRP fails. FRP failure cannot be

shown in ANSYS. The failure in FRP is checked with Tsai-Wu failure criteria (4).

3.3. Validation of the Model

Six sets of existing published experimental results by the Howie and Karbhari (12), Karbhari and

Gao (14), Rochette and Labossiere (36), Xiao and Wu (50), Tountaji (45), Tountaji and Balaguru (46)

were considered to validate the FEA model. Assumptions have been made regarding the

present analysis automatic loa

ANSYS to determine the number of load steps required for an accurate solution. Substeps are

defined to apply the loads gradually. The number of substeps used for the simulation was 100,

which sets the initial sub step to 1/100th of the total load. Providing all the necessary input, the

simulation was performed.

3.2.7. Solution

23

Page 35: Modeling of Fiber Reinforced Polymer confined concrete ...

unavailable data. The summary of the material properties used for one of the specimens from the

experiments conducted is given by Table.3.1.

Figure 3. Cracking and Crushing in Concrete

. S aterial properties of the FRP for one set of ens t r d.

ata ollected

FRP Composite

Elastic Modulus

Poisson’s Ratio

Shear Modulus

Tensile Strength

Thickness (mm)

7

Table.3.1experimen

ummary of mesults considere

specim from the

Dcfrom (MPa) (MPa) (MPa) Howie and Karbhari

Carbon/Epoxy 73300=E8.4613=yE 8.4613=zE 019.0

39.0

31.0

=

=

=

zx

yz

υ

υx xyυ

1761

49.1659

1761

=

=

=

zx

yz

G

G

G 755 0.31 xy

24

Page 36: Modeling of Fiber Reinforced Polymer confined concrete ...

Table 3.1 continued

and Gao

x

16.5399=E16.5399=zE

016.0

43.0

=

=

Karbhari Carbon/Epoxy E

45.2001

1.1882

=

=

45.200196032=

y

29.0=

zx

xy

υ

υ yz

υ =

zx

xy

G

G

yz

G 1353 1.55

Rochette and Labossiere

Aramid/ Epoxy

13600=xE 1.1482=

1.1482=zE 035.0=

=yE 35.0

32.0=

zx

xy

υ

υ yz

υ

13.549=

=547

13.549=

zx

xy

G

G

230 3.86

yzG

Xiao and

Carbon/Epoxy 1=xE4.0

29.0

6.2057

7.2144

Wu

=

=050002.5784=yE 2.5784=zE 40.0=zxυ

yz

xy

υ

υ

=

=

7.2144=zxGyz

xy

G

G

1577 0.76

Tountaji Carbon, Glass/ Epoxy

44500=xE

5603=zE 03.0

27.0

= 5.2084

5.2084

=

5603=yE 38.0=

=

zx

υ yz

xy

υ

υ

7.2023=

=

zx

Gyz

xy

G

G 1518 0.24

Tountaji and Balaguru

Carbon, Glass/ Epoxy

137740=xE

6.5785=E 035.0

27.0

=

6.5785=yE

z

38.0=

=

zx

υ yz

xy

υ

υ

4.2023=

9.2079

9.2079

=

=

zx

G

yz

xy

G

G 3485 0.22

The strengths, moduli and thicknesses of the specimen vary from one research group to another.

The above table summarizes the material properties of one such specimen considered from the

collected data. In the papers considered, the modulus of elasticity and the strength were given

d a o t e vol e fraction. Therefore, the m terial properties are calculated

using nd macro mechanical equations available (see Sec.3.2.3). ion in

in the hoop direction ( h ve c red f alida

t a e i o s n d r s ons d on the

previo ature data were ed in case of insufficient or unavailable data. The

ta a as e r c t m ta we ractically

appropriate and were not arbitrary values. Care was taken when applying these values in for

running the finite element analysis.

inclu ing

micro a

fewer det ils f h um a

The fiber orientat

all the above cases are 00 ). In t e abo papers onside or v tion,

no ll the nin

us available liter

mater al pr pertie were co sidere . The efore, as umpti base

consider

da ssumed w the r sult of extensive resea ch, su h tha the assu ed da re p

25

Page 37: Modeling of Fiber Reinforced Polymer confined concrete ...

FEA simulation was run with all the different model data. Comparison between the FEA

d a l t A sim io ed ar bl he re

of the FEA simulation were approximated and curve fitted such that the error between the FEA

u n e f pu d r th ccep

range. The Table below summarizes the experimental and FEA results.

l C en es n s

No. Source mm mm MPa

FType mm MPa MPa MPa MPa

A)

(e) %

an the experiment l resu ts show tha the FE ulat ns pr ictions e relia e. T sults

res lts and the experime tal r sults rom the blishe pape s remain below e a table

Tab e 3.2 omparison of Experim tal R ults a d FEA re ults.

of Data

t frpf frpE ccf d h cf iber ccf

(Exptl.) (FE1 Howie

and Karbha

1

ri (1994)

3 Carbon s

0.3 5 3 541.9, 47.2

52 05 38.6 heets

1 7 5 7 300 4 .5, 41 -2.14

2 Howie and Karbha

1

ri

3 Carbon s

0.6 0 0 660.6, 61.9

0.99

(1994)

52 05 38.6 heets

1 1 47 7 600 5 .5, 60 -

3

152 305 38.6 Carbon sheets

0.92 1105 77500 76.4,

5

75 -Howieand Karbhari(1994)

80.9, 7 .8

1.05

4 Howie and Karbhari

152 305 38.6 Carbon s

1.2 3 589.5, 89 heets

2 1 52 9 700 89.9, 92 2.33

(1994)

5 Karbhari and Gao (1997)

152 305 18.0 Carbon sheets

1.55 1353 96032 82.2 82 -0.2

6 Karbhari and Gao

152 305 18.0 Carbon sheets

2.06 1127 150150 70.6 70 -0.84

(1997)

7 Karbhari and Gao (1997)

152 305 18.0 Carbon sheets

5.31 513 35856 82.3 80 -2.4

26

Page 38: Modeling of Fiber Reinforced Polymer confined concrete ...

Table 3.2 continued

The above results have been published in the Lam and Teng (12) paper. The calculations are

shown in the appendix. In the table, is the diameter, is the height, is the thickness, is

the unconfined strength of the concrete, is the tensile strength of the composite, is the

modulus of the composite, and is the confined concrete strength.

152 305 18.0 Glass and

2.26 978 62504 79.5 81 1.888 Karbhari and Gao (1997)

Carbon sheets

9 Rochette and Labossiere (2000)

150 300 43.0 Aramid sheets

1.27 230 13600 47.3 45 -4.86

10 Rochette and Labossiere (2000)

150 300 43.0 Aramid sheets

2.56 230 13600 58.9 60 1.86

11 Xiao and Wu (2000)

152 305 33.7 Carbon sheets

0.38 1577 105000 47.9, 49.7,

53 6.6

49.4 12 Tountaji and 76 305 31.8

Balaguru (1998)

Glass sheets

0.24 1518 69000 63.2 63 -0.3

13 Tountaji and 76 305 31.8 Carbon Sheets

0.22 3485 228000 98.7 95 -3.74Balaguru

(1998)

14 Tountaji and 76 305 31.8 Carbon Sheets

0.33 2940 373000 96.0 100 4.16Balaguru (1998)

15 Tountaji 76 305 31.0 Glass sheets

0.24 1518 72600 60.8 61 0.3 (1999)

16 Tountaji 76 305 31.0 Carbon sheets

0.22 3485 230500 95.0 96 1.05(1999)

17 Tountaji 76 305 31.0 Carbon sheets

0.33 2940 372800 94 95 1.06(1999)

d h t cof

frpf frpE

ccf

27

Page 39: Modeling of Fiber Reinforced Polymer confined concrete ...

3.4. Conclusions

The comparison between the icted by FEA show that the

liable. The above FEA model was also validated using an analytical model,

can be developed to predict the strength and ductility of the

columns.

experimental results and the results pred

FEA results are re

which is developed using the basic fundamental principles involved. The present FE model can

be utilized as a tool to develop a very large test database with taking into account all the possible

ranges of the parameters affecting the confined concrete strength. Based on the test database, a

design oriented confinement model

FRP confined concrete

28

Page 40: Modeling of Fiber Reinforced Polymer confined concrete ...

4. PRACTICAL BOUNDS AND BENCHMARK ANALYTICAL SOLUTIONS FOR CONFIRMATION OF FE MODEL

4.1. Introduction The present chapter focuses on the analytical solutions for limiting cases of FRP confined

concrete. These solutions can be used as bounds on the stress and displacement fields of the FRP

confined concrete. The fundamental principles involved in the mathematical formulation of the

problem are thoroughly explained.

4.2. Practical Bounds

A clear explanation of the problem is given in this chapter. The behavior of the concrete column

wrapped with FRP composit n of a load bearing member

f a concrete slab.

e is determined using practical applicatio

o

Consider a concrete slab of length l , breadth b and height h as shown in Figure 4.4. The

slab is supported by four concrete columns of diameter d and length cl . The pressure exerted by

the slab on the each column is p , where

24 rFπ

F is the force exerted by the slab, and

p= (4.1)

r is the radius of the concrete column. Consider the

concrete column, without load. The volume of the column is given by

clrV 2π= )

If the pressure is applied on the top of the concrete column unif

th be

compressed longitudinally without ch ension of its radius

(4.2

ormly, then from the classical p

eory of elasticity point of view the problem is one-dimensional, and the column will

. If the pressure is anging the dim r

29

Page 41: Modeling of Fiber Reinforced Polymer confined concrete ...

applied non-uniformly, or if the top

30

cl

d

cl

d

of the column is subjected to additional moment, the

problem becomes three-dimensional, and the colum ormed

nloaded concrete columns

direction as well. The objective of this section is to determine the ability of the FRP tube to

n when it is compressed and cracks start

to develop. To get a feeling regarding the po

olume of the column is conserved. Note that this is

a conservative assum guments the volum

must be smaller than that of the uncompressed one. Let the dimensions of the compressed

n geometry is def in the transverse

Figure 4.1 U

withstand extension in the radial direction of the colum

ssible transverse extension of the radius we will

assume the non-physical assumption that the v

ption since by physical ar e of the compressed column

column be 1l and 1r for the length and radius, respectively. Then it follows that

( )ε−= 11 cll (4.3)

Ep

=ε (4.4)

E , is the Mo n is given by dulus of elasticity of the concrete. The volume of the loaded colum

(4.5) 12

11 lrV π=

Page 42: Modeling of Fiber Reinforced Polymer confined concrete ...

The change in the radius is obviously

rrr −=∆ 1 (4.6)

the volume is conserved then we have

If

1VV = (4.7)

nd hence, we obtain from (4.2) and (4.5)

(4.8)

ubstituting (4.3) into (4.8) gives

A

12

12 lrlr c =

S

( )ε−= 121

2 rr (4.9)

So that,

( )ε−=

11rr (4.10)

Substituting (4.4) into (4.10), we obtain

( )Ep−11

However, if the slab is supported by four column, then

rr = . (4.11)

24 rgbhlpπ

ρ= (4.12)

Substituting (4.12) in (4.11) we finally obtain

( )2141 rEgbhl

rπρ−

= (4

Similarly, su

r .13)

bstituting (4.12) in (4.3) we finally obtain

( )21 41 rEgbhlll c πρ−= (4.14)

31

Page 43: Modeling of Fiber Reinforced Polymer confined concrete ...

Now, let the concrete column be wrapped with a fiber reinforced polymer of thickness as

own in Figure 4.2. The inner radius of the column is

t

sh r and the outer radius .

Figure 4.2 FRP wrap of thickness

4.2.1. Assumptions

In the pr

s of the concrete are retained.

Let be the internal pressure in the column which extends the radius

trro +=

t

esent formulation the FRP composite is considered as homogenous, isotropic and

linearly elastic in nature. Therefore, its general orthotropic properties of the FRP are neglected.

The composite is wrapped along the circumferential direction of the concrete column. However,

the propertie

ip r to . Figure 4.3

1r

shows a free body diagram of a small section of the composite tube subjected to this internal

pressure.

32

Page 44: Modeling of Fiber Reinforced Polymer confined concrete ...

.3 Free body diagram of the FRP element

n by

Figure 4

Let u be the radial displacement in the FRP due to the internal pressure ip . Therefore, the

general solution (see e.g. [32] p. 560) for the radial displacement u at any point is give

ξξ 2

1AAu += (4.15)

, are constants which are determined from the boundar21 , AA y conditions and ξ is the radial

ate. For determination of the constants, the radial stresses 21 , AA rσ actingcoordin on the

elements at their respective radii are considere the

present case. Therefore,

d which serve as the boundary condition for

( ) ir pr −=σ , ( ) oor pr −=σ

Here ip is the internal pressure, and op is the external pressure. In the present case, the externa

pressure vanishes. Hence, the boundary conditions become

l

( ) ir pr −=σ (4.16)

( ) 0=or rσ (4.17)

The coefficient and in Equation (4.15) are (see [32], p. 561) 1A 2A

33

Page 45: Modeling of Fiber Reinforced Polymer confined concrete ...

( )( )

220

2

1211

rrrp

EA i

−−+

=νν (4.18)

( )

220

20

2

21

rrrrp

EA i

−+

=ν (4.19)

e therefore obtain

W

( )

( )( ) ( )22

0

20

2

220

2

21

1211rrrrp

Errrp

E

AAu

ii

−+

+−

−+

+=

ξνξνν

ξξ (4.20)

ξ

=

Substituting the boundary conditions (4.16) (4.17) we have

( ) ( )( )( )

( ) ( )( )

rrrtr

trrpErtr

rpE

ru ii −=−+

+++

−+−+

= 122

2

22

3 1211 ννν (4.21)

( ) ( )( ) ( )( )

( ) ( )( )

( )trtrrtrtrrp

Ertrtrrp

Etru ii +−+=

−+

+++

−+

+−+=+ 1122

2

22

2 1211 ννν (4.22)

ence, and a

where 1t is the thickness of the deformed tube. Equations (4.21) and (4.22) are two equations

with two unknowns, ip and 1t . H re determined by (4.21) and (4.22).

The tangential stress θ

ip 1t

σ is then determined by ([32], p. 561)

( ) 21 ξθC

where

( )

2ξσ C += (4.23)

221

2

rtr

rpi

−+1C = (4.24)

and ( )

( ) 221

21

2

2rtr

trrpi

−+

+C = (4.25)

34

Page 46: Modeling of Fiber Reinforced Polymer confined concrete ...

35

lb

h

lb

h

order to explore the pressure at the interface between the concrete and the FRP we consider

e case where the concrete slab is supported by four FRP confined concrete column.

Figure 4.4 Concrete slab

Let the concret dime

In

th

e slab have the following nsions:

20=l m, 10=b m, 1=h m, 2.0=r m

and we used t as a parameter with minimal value 001.0min =t .

From (4.13) we obtain

20003.01 =r m

nd from (4.12) we determined

Pa.

hen by using (4.21) through (4.22) we determine the values shown in Figures (4.5), (4.6), and

.7), showing the ratios

a

71097.8 ×=p

T

(4 pθσ and ( ) prpp ri σ−= for various ranges of wall thickness . It

found that in the limit where is very large the radial and tangential stress are approximately

9 of the applied pressure . This is an important physical property that determines the limit

of application of the FRP. The implication of this result is that the stress applied by the FRP

t

t

%

is

1 p

Page 47: Modeling of Fiber Reinforced Polymer confined concrete ...

0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10

0.05

0.1

0.15

0.2

0.25

0.3

0.35

t (m)

(Pa) pθσ

( ) (Pa) r pp rpi σ−=

0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10

0.05

0.1

0.15

0.2

0.25

0.3

0.35

t (m)

(Pa) pθσ

( ) (Pa) r ppp ri σ−=

cannot exceed a certain value by increasing the wall thickness considerably. In other words, for

this case, the FRP can possibly apply only 5/1 of the pressure which is exerted by the concrete

slab at the top end of the column. This signifies that for a new concrete column with out cracks,

FRP does not provide proper confinement. From, the stress-strain plot Figure.1.1 shows that FRP

starts confining the concrete column after the concrete column has reached its ultimate strength.

Figure 4.5 Variation of

( )rθσ /p and /p with respect to thickness t

enerally, in repaired cases of concrete columns where the concrete is already been cracked /

icts its further expansion

ip G

crushed, the wrapping of the concrete columns with the composite restr

in lateral direction preventing it from failing. Since, the load bearing component is the composite

itself.

36

Page 48: Modeling of Fiber Reinforced Polymer confined concrete ...

37

0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.50

0.05

0.1

0.15

0.2

0.25

0.3

0.35

t (m)

(Pa) pθσ

( ) (Pa) r ppp ri σ−=

0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.50

0.05

0.1

0.15

0.2

0.25

0.3

0.35

t (m)

(Pa) pθσ

( ) (Pa) r ppp ri σ−=

0 0.5 1 1.5 2 2.5 30

0.05

0.1

0.15

0.2

0.25

0.3

0.35

t (m)

(Pa) pθσ

( ) (Pa) r ppp ri σ−=

0 0.5 1 1.5 2 2.5 30

0.05

0.1

0.15

0.2

0.25

0.3

0.35

t (m)

(Pa) pθσ

( ) (Pa) r ppp ri σ−=

Figure 4.6 Variation of ( )rθσ /p and ip /p with respect to thickness t

Figure 4.7 Variation of

( )rθσ / p and /p with respect to the thicknessip t

Page 49: Modeling of Fiber Reinforced Polymer confined concrete ...

38

4.3. Analytical Solution for a Column Loaded by Transverse Load

Consider a cylinder of length , radiusl r with a uniform cross section. The z-axis coincides with

the axis of the cylinder. The beam is fixed at one end ( )0=z and free at the other end ( )lz = . The

cylinder is subjected to a transverse load , atP ( )lz = .

Since the bending of the cylinder is about the X-axis

0=== θθθ σσσ rrr (4.26)

o rete subjected to a transverse load

YP

Figure 4.8 C nc P

The normal stress varies uniformly along the cross section, therefore

( )( )zlCrBrzz −+= θθσ sincos

Where are constants

s from Cartesian to Cylindrical coordina

Table.4.1 Transformation matrix

(4.27)

CB ,

Transforming the stresse te system,

⎪⎭

⎪⎬

⎪⎩

⎪⎨

⎥⎥⎥

⎢⎢⎢

⎡−=

⎪⎭

⎪⎬

⎪⎩

⎪⎨

zyx

z

r

1000cossin0sincos

θθθθ

θ

Z

X

l

YP

l

X

Z

Page 50: Modeling of Fiber Reinforced Polymer confined concrete ...

Writing the transformation equations

( ) ( ) ( ) ( ) θτθτθθτσθσθσσ cos020)(sin2cossin20sincos 22xzyzxyzyxr +++++=

( ) ( ) ( ) ( )( θτθτθθτσθσθσσθ sin020)(cos2cossin20cossin 22 −++−+++= xzyzxyzyx )

( ) ( ) ( ) ( ) ( ) ( )1020)1(202100 xzyzxyzyxz τττσσσσ +++++=

( ) ( ) ( ) ( ) ( )[ ]( ) ( )( )[ ] ( ) ( )( )[ ]θθτθθτ

θθθθτσθθσθθστ θ

sin0cos00cos0)(sin

sinsincoscos0cossinsincos

−++++

−++++−=

xzyz

xyzyxr

( )[ ] ( )( )[ ] ( )[ ] ( )( ) ( )[ ]( ) ( )( )[ ] ( )( ) ( )[ ]θτθτ

θθτσθσθστ

cos100001)(sin

sin00cos100sin0cos

++++

++++=

xzyz

xyzyxrz

( )[ ] ( )( )[ ] ( )[ ] ( )( ) ( )( )[ ]( ) ( )( )[ ] ( )([ sin1001)(cos

cos0sin

−++ ) ( )( )]00

cos00sin100

++

+−+++−=

θτ

θθτσθσθστθ zyxz

θτ xzyz

xy

Solving the above six equations, we get the stresses as

0=rσ (4.28)

0=θσ (4.29)

z zσσ = (4.30)

0=θτ r (4.31)

θτθττ cossin xzyzrz += (4.32)

θτθττθ sincos xzyzz −= (4.33)

Application of boundary conditions will result in obtaining the stress and the displacements in

the cylinder.

(4.34)

The boundary conditions at ( )0=z

( ) PrdrdR

zrz −=+∫ ∫π

θ θθτθτ2

0 0

cossin

39

Page 51: Modeling of Fiber Reinforced Polymer confined concrete ...

x

P

0=z

rzτzθτ

θPLM x =

(4.35)

he below Figure 4.9 shows the free body diagram of the cylinder at

( ) 0sincos2

0 0

=−∫ ∫π

θ θθτθτR

zrz rdrd

( )0=z T

Figure 4.9 Boundary onditi ns at

c o ( )0=

The boundary conditions at ( )lz =

0

z

=zσ (4.36)

( ) Prdrdzrz =+∫ ∫ θ θθτθτ cossin (4.37)

(4.38)

z PLx

Rπ2

0 0

( ) 0sincos2

0 0

=−∫ ∫π

θ θθτθτR

zrz rdrd

0sin2

0 0

=−∫ ∫π

θθσR

rdrdr M = (4.39)

40

Page 52: Modeling of Fiber Reinforced Polymer confined concrete ...

( ) 0cos2

0 0

=∫ ∫π

θθσR

z rdrdr 0=yM (4.40)

0 0

=∫ ∫π

θ θτR

z rdrdr ( ) 02

0=zM (4.41)

The Figure 4.10 is the free body diagram, of the cylinder at ( )lz =

x

y

P

lz =

rzτzθτ

θ

Figure 4.10 Boundary conditions on the surface

( )lz =

41

The boundary condition on the free surface, Rr =at

0=rσ (4.42)

0=rzσ (4.43)

0=θσ r (4.44)

The Figure 4.11 below shows the stresses on the free surface of the cylinder

Page 53: Modeling of Fiber Reinforced Polymer confined concrete ...

42

rσrzτ

θτ r

Figure 4.11 Boundary conditions on the lateral surface of the cylinder

he equilibrium equations are

Rr =at

T

( ) ( ) ( ) 011=−+

∂∂

+∂∂

+∂∂

θθ σσττθ

σ rzrrr rzrr (4.45)

( ) 021=

∂∂

++∂∂

+∂∂

zrr zrrr θθθθ ττσθ

τ (4.46)

011=

∂∂

+∂∂

++∂∂

zrrrz

zzrzrσ

τθ

ττ θ (4.47)

pplying the boundary conditions and substituting them in the compatibility equations we get

e stresses as

A

th

( )zlrIP

xxzz −⎟⎟

⎞⎛⎜⎜⎝−= θσ sin (4.48)

⎟⎠

⎞⎜⎝

⎠⎞

⎝⎛

++υυ

121

41 2

IP

xxzr

⎟⎜ ⎟⎜−= θθτ cossinr (4.49)

( )⎟⎜ ⎟⎜θ sincos rraz ⎟⎠

⎞⎜⎝

⎛−

⎠⎞

⎝⎛

+−

−++

= θννθ

νντ 22222

2321

81

123

IP

xx (4.50)

Verifying the above equations in maple, we find that the stresses satisfy all the boundary

conditions. See Appendix A.

Page 54: Modeling of Fiber Reinforced Polymer confined concrete ...

4.4. Conclusions

The present chapte

r thoroughly explains the fundamental principles involved in the FRP

FRP confined concrete have been

confined concrete. Practical bounds for the limiting cases of

discussed. These bounds were explained by taking a practical case of FRP confined concrete

column subjected to the pressure exerted by a concrete slab. Analytical solution for column

subjected to transverse load was also derived.

43

Page 55: Modeling of Fiber Reinforced Polymer confined concrete ...

5. CRITICAL PARAMETERS IDENTIFICATION AND EVALUATION

.1. Introduction

he developed finite element model of FRP confined concrete column accurately predicted the

onfined concrete strength. The model has been validated using the experimental results

ollected from the available literature. Analytical solution for the limiting cases of FRP confined

ers and Their Range

5

T

c

c

concrete was also discussed which clearly explained the basic principles involved in the confined

columns. The purpose of this chapter is to identify parameters that have a considerable effect on

the confinement effectiveness and evaluate their effect through the validated FEM analysis. This

will help understand how each parameter influence the structural behavior of FRP confined

concrete cylinders.

5.2. Identification of Design Paramet

From the literature, it was found that various parameters affect the confinement effectiveness of

FRP confined concrete cylinders. These include the FRP wall thickness, t, compressive strength

of unconfined concrete, cf , modulus of elasticity of the fiber, fE , modulus of elasticity of the

matrix, E , modulus of elasticity of the composite, E , ultimate tensile strength of the matrix, m frp

muσ , ultimate compressive strength of the matrix, cuσ , ultim r strength of the matrix, ate shea τ ,

tensile strength of fiber, fuσ , and hoop tensile strength of the composite, . It is noted that

not all the parame ependent, for instance and can be found through the

matrix and fiber properties and fiber volume fraction using the rule-of-mixture’s method.

Therefore, only the following four parameters are identified as essen ials. They are the FRP wall

thickness t, compressive strength of unconfined concrete , hoop modulus of elasticity of the

composite , and hoop tensile strength of the composite, . Through an extensive

frpf

ters are ind frpE frpf

t

cf

frpE frpf

44

Page 56: Modeling of Fiber Reinforced Polymer confined concrete ...

literature review, the range for the above identified parameters is listed in Table 5.1. The refined

steps for each parameter in the FEM analysis are also given in Table 5.1.

Table.5.1. Summary of the various design parameters and their respective ranges.

ifferent possible combinations of these parameters have been used and a database of more than

strength and hoop tensile strength of the composite. Based on the modeling

ement effectiveness is evaluated.

the real world. The present

study shows that there is an increase in the confinement effectiveness with respect to the

No. mm MPa MPa MPa t cf frpE frpf

1 0.1 8.27 4300 200 2 0.25 13.7 8925 300 3 0.5 20.6 11900 400 4 0.75 27.5 39625 500 5 1 34.4 43150 600 6 1.5 48.2 47225 700 7 2 55.1 77700 800 8 2.5 68.9 95525 900 9 3 75.8 116100 1000 10 3.5 89.6 128100 1125 11 4 96.5 162650 1250 12 4.5 110.3 179600 1375 13 5 117.2 246050 1500 14 5.5 124.1 422500 1750 15 6 131 465500 2000

D

500 models was developed using validated FEM model. In the Appendix [B] the table no. 1-40,

give the details about the confined concrete strength for different combinations of thicknesses,

unconfined concrete

results, the effect of each individual parameter on the confin

5.2.1. Effect of FRP Wall Thickness

In the developed models, the thickness ranges from a minimum value of 0.1 mm to 6mm. The

range indicates that the models cover the possible thicknesses of the composite for confining the

concrete. The range considered is applicable for most of the cases in

45

Page 57: Modeling of Fiber Reinforced Polymer confined concrete ...

thickness. When the confinement effectiveness is plotted against the thickness from tables 1-15

e obtain a plot as shown in Figure 5.1

Figure 5.1 Effect of thickness on the confinement effectiveness

It is clear from the plot that the confinement effectiveness is dependent on the thickness. This

plot signifies that the relation between the confinement effectiveness and the thickness might not

be linear in nature.

5.2.2. Effect of Hoop Tensile Strength of the Composite

It is known that the confinement effectiveness depends on the hoop tensile strength of the FRP.

Figure 5.2 gives us a view of the effect of hoop tensile strength of the FRP on the confinement

w

46

Page 58: Modeling of Fiber Reinforced Polymer confined concrete ...

effectiveness. Plotting the confinement effectiveness with respect to the hoop tensile strength

roadens the idea about the relation between them (see tables 16-30).

oncrete Strength

s low strength concrete of 8.27 MPa to super high strength concrete of 131

in

b

Figure 5.2 Effect of hoop tensile strength on the confinement effectiveness

The plot shows that the confinement effectiveness follows a nonlinear curve with respect to the

hoop tensile strength.

5.2.3. Effect of Unconfined C

The range include

MPa. Increase in the concrete strength decreases the confinement effectiveness. Therefore, we

can say that the confinement effectiveness also depends upon the unconfined concrete strength.

The Figure 5.3 supports the above statement (tables 31-40). The curve follows a path indicating

that the relation between the confinement effectiveness and the unconfined concrete strength is

nonlinear nature.

47

Page 59: Modeling of Fiber Reinforced Polymer confined concrete ...

F s

5.2.4. Effect of Modulus of Elasticity of FRP

ittle has been studied about the effect of the modulus on the confinement effectiveness. It can

e seen from the Figure5.4 that the confinement effectiveness changes with the change in the

odulus (see tables1-40). It can be said that the higher the modulus of the FRP, the better the

onfinement of the column.

.3. Conclusions

he above discussion has shown that the confinement effectiveness depends on the four design

arameters. Therefore, in order to cater to the nonlinear behavior of the confinement

effectiveness, it can be concluded that a function describing the relation between the confinement

igure 5.3 Effect of unconfined concrete strength on the confinement effectivenes

L

b

m

c

5

T

p

48

Page 60: Modeling of Fiber Reinforced Polymer confined concrete ...

49

eff te

modulus of elasticity should be derived.

ectiveness coefficient k and the thickness t , hoop tensile strength frpf , unconfined concre

strength f and thec frpE

Figure 5.4 Effect of modulus of the composite on the confinement effectiveness

Page 61: Modeling of Fiber Reinforced Polymer confined concrete ...

6. A NOVEL APPROACH FOR A DESIGN-ORIENTED CONFINEMENT MODEL

6.1 Introduction

In Chapter 5, the essential parameters and the range for each parameter has been identified.

RP composite and the

unconfined concrete strength i d l The effect of

individual parameters was also studied in detail. The study has shown that the confinement

effectiveness depends s ifi n with a nonlinear nature. Thus, to cater to

is nonli ar behavior the coefficient of confinement effectiveness should be expressed as a

s

finement effectiveness has to be taken into account. The present

divisions of all the design parameters were considered

hich lead to several thousand possible combinations. However, only 545 possible combinations

have been modeled and used for analysis. A multivariate statistical analysis was performed n

the generated database to obtain the curve of best fit. When tested for models lying within the

considered range of the parameters but not the models considered in the database, the curve fit

was not successful in predicting the confinement effectiveness coefficient accurately. The

variation in order of dimension of these design parameters was also a contributing factor for

Thickness t , hoop tensile strength frpf , modulus of elasticity frpE of the F

cf were dentifie as the essentia parameters.

ign cantly o these parameters

ne kth

function of thickness, hoop tensile strength, modulus of elasticity and unconfined concrete

strength. Therefore, to develop a confinement model for the FRP confined concrete columns thi

nonlinear behavior of the con

chapter focuses on developing such a confinement model.

6.2. Proposed Confinement Model

6.2.1. Generation of Models

In the generation of the test models, 15

w

o

inaccuracy in the prediction.

50

Page 62: Modeling of Fiber Reinforced Polymer confined concrete ...

In order to obtain better results, the range of the essential parameters was condensed. The

parameters were divided into two equal divisions each such that there will be sixteen possible

combinations. The variation in the order of dimension was also eliminated by scaling the

parameters such that the thickness was in meters and the other parameters were in GPa. Table 6.1

ives the summary of the ranges of parameters.

Table 6.1 Summary of the ranges of the parameters

No. t (m) cf (GPa) frpf (GPa) frpE (GPa)

g

1 0.0005 0.02 0.35 40

2 0.0035 0.08 1.5 250

Sixteen models of the above parameters were generated using FEA and an expression for

6

p e f bles ar

function to describe the relation among these dependent and independent variables has to be

etermined. The problem deals with several variables; therefore a multi variable model for the

ata can be defined using a polynomial,

+++++++++++++++=

(6.1)

er

confinement effectiveness coefficient was obtained which is discussed in the following section.

.2.2. Mathematical Model

In this problem, k is the de endent variabl and our independent varia e t , frpf , frpE , cf

A

d

d

4321164321543114421133211243114210

32941831721645342312011)(

xxxxAxxxAxxxAxxxAxxxAxxAxxAxxAxxAxxAxxAxAxAxAxAxAxy

H e y , represents the dependent variable and are the thickness , hoop tensile

rength , unconfined concrete strength and modulus of elasticity of the composite

k 43,21 ,, xxxx t

frpf cf frpE st

51

Page 63: Modeling of Fiber Reinforced Polymer confined concrete ...

respectively. The above form a set of simultaneous linear equations with unknown coefficients

etc. All the equations causing singularity in the above

xpression were eliminated. Therefore, the solution can be approximated by applying method of

ast squares, in which the sums of the squares of the deviations of the data from the model are

of

unknown coefficients, a pseudo-inverse method is applied. The

eory behind pseudo-inverse method can be seen in Appendix C. Figure 6.1 shows the predicted

obtained from the FE models. The above plot confirms that

nt variable and the

ind e b efore, based on the

abo e od

equation

161511106521 ,,.....,,.....,,,....,, AAAAAAAA

e

le

minimized. A MATLAB code was developed to generate the solution for the above system

linear equations. To obtain the

th

k value with respect to the actual k

the multi variable polynomial defines a perfect relation among the depende

ependent variabl s. The error in the prediction of k is elow 10%. Ther

ve relation a n w confinement m el was proposed introducing the above relation in

m

c

l

c

ccff

kff

⎟⎟⎠

⎞⎜⎜⎝

⎛+= 1 , where

0

xxxxAxxxAxxxAxxxAxxxAxxAxxA

of elasticity of the composite respectiv =1, confining pressure.

4321164321543114421133211243114210

3294183172164534231211 xxAxxAxxAxxAxAxAxAxAxAk

+++++++

++++++++=

(6.2)

43,21 ,, xxx , are the thickness t , hoop tensile strength frpf , unconfined concrete strength cf and

modulus

x

frpE ely, m lf

52

Page 64: Modeling of Fiber Reinforced Polymer confined concrete ...

from the expression with actual ‘k’ s.

And the coefficients obtained are

68318, = 44.94609996,

= -15697.97733, = -0.38881956,

= -29.6398204, = -0.000107517, = 0.034455227, = 8208.360127

= -0.624166485, = -14.06277535, = 0.031921929, = -3.901040487

ndent variables effecting . This

Figure 6.1 Plot showing variation of the predicted values values from the FEA result

1A = -0.043677143, 2A = 658.0099117, 3A = 0.6671 4A

5A = 0.003719048, = -428.0012328, 6A 7A 8A

9A 10A 11A 12A

13 14 15 16A A A A

The proposed confinement model considered the value of empirical constant m to be equal to

one, in order to reduce the complexity of the problem. A higher order polynomial should be

defined if m was also considered as one of the indepe k

53

Page 65: Modeling of Fiber Reinforced Polymer confined concrete ...

possibility of is research and is

subject to future s s.

6.3. Illustration of the Proposed Confinement Model

t c c s h n p ters are

t the confined concrete strength. For example, consider the

) = 0.00062 m

Hoop tensile strength ( ) = 0.5 GPa

the m being an independent variable is out of the scope of th

tudie

From he proposed confinement model, it an be learly een that if all t e desig arame

known, then one can easily predic

following values for the design parameters with in the range considered.

Thickness t ( 1x

frp

Unconfined concrete strength cf ( 3x ) = 0.04 GPa and

Modulus of elasticity of the composite frpE ( 4x ) = 70 GPa

Substituting the coefficients and the above values in equation (6.2), k can be calculated

82.1

f 2x

=k

The confining pressure, is given by the

lf

dtf frp2

f l = (6.3)

ubstituting the thickness an h equation where the diameter

= 0.152 m.

herefore, the confining pressure is obtained as

0.00 Pa

es of and , in the equation (6.2)

S d the oop tensile strength in the above

d

T

lf = 407 G

lf kSubstituting the valu

m

cc ff

ff

⎟⎠

⎞⎜⎝

The confined concrete strength can be obtained as

lcc k ⎟⎜+= 1

54

Page 66: Modeling of Fiber Reinforced Polymer confined concrete ...

55

⎟⎟

⎜⎜

⎠⎞

⎝⎛

04.000407.0

cc

0474.0

⎟⎜+= )82.1(1)04.0(f

=ccf GPa

Thus, from the illustration it is clear that if the required design parameters are known, then using

the equation (6.2) the confined concrete strength can be obtained.

6.4. Comparisons and Limitations of the Confinement Model

To obtain an accurate solution, the range of the design parameters was condensed and the details

are summarized in Table. 6.1. From the available literature, the following are the two

experimental results which come under the range considered.

Table 6.2 Summary of the models within the considered range

From the existing confinement models, the confinement effectiveness coefficient can be

alcula

(6.4)

MPa MPa No. Source of Data d

mm h mm

cf MPa

Fiber Type t mm frpf frpE

Set 1 Howie and Karbhari (1994) 152 305 38.6 Carbon sheets 0.92 1105 77500Set 2 Howie and Karbhari (1994) 152 305 38.6 Carbon sheets 1.22 1352 95700

c ted as

( )l

cccf

ffk

−=

But, from the proposed confinement model, the confinement effectiveness coefficient is

calculated from equation (6.2). A comparison of prediction of the confined strengths and the

confinement effectiveness coefficients are given in table 6.3. An overall comparison shows that

the proposed model grossly under-predicts the confinement effectiveness coefficient and

indirectly under-estimates the confined concrete strength.

Page 67: Modeling of Fiber Reinforced Polymer confined concrete ...

Table 6.3 Comparison of the predictions of and

.4.1. Limitations

o encompass the nonlinear behavior of the confinement effectiveness with the critical

arameters, the proposed confinement model considers a multi-variable polynomial for

redicting confinement effectiveness coefficient . This polynomial considers four independent

parameters to represent one dependent parame . Interpolating these independent parameters

a four dimensional space requires a very complex empirical model which is outside the scope

of the present study. Very large numbers of models are required to get a good approximation for

ch a parametric representation. Therefore, it can be concluded that this is one possible reason

for the under-estimation of the strengths by the proposed confinement model.

Further research on the proposed confinement model indicated that the possible under-

prediction might be also due to the interdependency of the two of the four critical parameters, the

hoop tensile strength and the m

trix as well

No. Howie and Karbhari (1994)

Proposed Model

ccf k

MPa

MPa ccf k ccf k

Set 1 75.8 2.78 57.9 1.45Set 2 89.9 2.36 67.24 1.32

6 T

p

k

ter k

p

in

su

odulus of elasticity of the FRP. From empirical formula, the hoop

tensile strength of the FRP can be calculated once the moduli of the fiber and the ma

as their volume fraction are known or vice-versa. In the present considered ranges, both the

moduli of the FRP composite as well as its hoop tensile strength are considered as independent

parameters. Therefore, when all the possible combinations are modeled there exist few odd

combinations where the FRP has a very high stiffness but a very low strength which is not

56

Page 68: Modeling of Fiber Reinforced Polymer confined concrete ...

applica

ter focuses on developing a possible approach to develop a confinement model

which

ble in the real world. Hence, it can be said that either one of the two parameters has to be

eliminated or should be predicted from the other.

It can be seen that the range considered in the present model was small for any of the real

world applications to fit in.

6.5. Conclusions

The present chap

circumvents the nonlinear behavior of the confinement effectiveness with the identified

critical parameters from the test database. In the present work, it is seen that the proposed

confinement model under-predicts the confinement effectiveness coefficients, thus indirectly

under-predicting the confined concrete strength. The possible reasons for the under-prediction

were discussed in the previous section.

57

Page 69: Modeling of Fiber Reinforced Polymer confined concrete ...

7. CONCLUSIONS AND FUTURE WORK

An approach to develop a confine

ment model that accounts for the nonlinear behavior of the

eness with the critical design parameters has been proposed. Unconfined

The critical parameters were identified based on the results of the large test database.

A 3-D finite element model of the FRP confined concrete model was developed. The FE

model was validated using the experimental results of six different research groups available in

the literature. The validation has shown that the FE model accurately predicts the confined

concrete strength. Thus, the present FE model can be used to predict the confined concrete

strength for different dimensions and different material properties.

Analytical solution for the FRP confined concrete columns was formulated assuming the

FRP

practical application of the FRP confined concrete column as a load bearing member of a

oncrete slab. It was concluded that for a new concrete column without cracks the FRP does not

provide p

also deve

nges for them. A large test database was assembled with different combinations of these

identified tegically investigated to

exam

columns. nfinement effectiveness depends on four design

confinement effectiv

concrete strength cf , FRP wall thickness t , Hoop tensile strength frpf and Modulus of Elasticity

were identified as the critical design parameters which affect the confinement effectiveness. frpE

to be an isotropic, linearly elastic material. The solution was developed by considering the

c

roper confinement. Analytical solution for columns subjected to transverse load was

loped.

Extensive research has been done to identify the design parameters and to define possible

ra

ranges, based on the FE results. The test database was stra

ine the effect of various design parameters on the behavior of the FRP confined concrete

This study revealed that the co

58

Page 70: Modeling of Fiber Reinforced Polymer confined concrete ...

parameters, the thickness of the FRP, the unconfined concrete strength, the hoop tensile strength

and the m The effect of each parameter was also studied in detail.

effective

xpression for the confinement effectiveness coefficient was developed by considering a

particular set of 16 combinations of the four design parameters which were divided equally.

Pseud

confinem

onfinement effectiveness.

In

effectiveness coefficient, thus under-predicting the confined concrete strength. The possible

reasons f

model is required to represent the four parameters. It was also found that the hoop tensile

strength

ey are inter-dependent variables.

7.1. Futu

It is

oop strength or the modulus of elasticity should be eliminated from the independent variables

list. It is g the range of parameters which are much closer to the

real w

T pirical constant is considered to be one, to reduce the complexity

in der

of differe confinement model.

odulus of elasticity of the FRP.

To cater to the nonlinear behavior of the confinement effectiveness, the confinement

ness coefficient k was considered as a function of the four design parameters. The

e

o inverse method was applied to obtain the coefficients for the expression. Finally, a

ent model was proposed by considering the nonlinear relation which exists with the

c

the present work, the proposed confinement model under estimated the confinement

or such under-predictions were investigated and it was realized that a complex empirical

and the modulus of elasticity of the FRP cannot be assumed as independent variables, as

th

re Studies

suggested that to have a better solution one of the two inter-related parameters either the

h

also suggested that considerin

orld applications will also result in obtaining better results.

he value of the em m

iving the confinement model. Therefore, further research is needed to investigate the effect

nt values of m on the

59

Page 71: Modeling of Fiber Reinforced Polymer confined concrete ...

REFERENCES

1) Ahmad. S.H, Khaloo. A.R, Irshaid. A, “Behavior of concrete spirally confined by

2) ANSYS User’s Manual 10.0, Release 10.0, ANSYS, Inc., 2005.

3) . J.,

Machida A., Rizkalla. S. H., Triantafillou. T. C. , “Fiber Reinforced Polymer

-87.

5) Cusson D and Paultre P., “Stress-strain model for confined high strength concrete”

6) for flexural and axial compression

rd

7)

crete Research, 1982; 34 (122); pp: 191-202.

9) Feng, P., Lu, X.Z., Ye, L.P., “Experimental research and finite element analysis of

Materials. Gold Coast, Australia, Jun, 2002. pp:71-76

10) Hadi, M.N.S., Li, J., “External reinforcement of high strength concrete columns”,

11)

C jackets”, Fiber composite in infrastructure; proceedings of the Second International Conference on Composites in

12) Howie I, Karbhari V.M, “ Effect of materials architecture on strengthening efficiency

ture; new materials and methods of repair; proceedings of third materials engineering conference,

fiberglass filaments”, Magazine of Concrete Research, 1991, 43, pp: 143-148.

Bakis. C. E., Bank. L. C., Brown. V. L., Cosenza. E., Davalos. J. F., Lesko. J

Composites for Construction – State-of-the-Art Review”, Journal of Composites for Construction, Vol.6, No.2, May, 1 2002, pp:73

4) Berthelot. J.M., “Composite Materials, Mechanical Behavior and Structural Analyses”,

Springer, New York, 1999.

Journal of Structural Engineering 1995; Vol.121, pp: 468-477.

Fam. A. Z, Rizkalla S.H, “Concrete filled tubes members. 3 International conference on advanced composite materials in bridges and structures, Aug 2000; pp: 315-322.

Fardis M. N, Khalili H. “FRP encased concrete as a structural material”, Magazine of Con

8) Fardis. M. N, Khalili. H, “Concrete encased in fiberglass-reinforced plastic”, ACI

Journal. 78, 1981 pp:-440-446.

square columns confined by FRP sheets under uniaxial compression”, Proc. 17th Australasian Conference on the Mechanics of Structures and

Composite Structures, 2003.

Harries, K.A., Kestner, J., Pessiki, S., Sause, R., Ricles, J., “Axial behavior of reinforced concrete columns retrofit with FRP

Infrastructure, ICCI’98 ,Arizona, 1998., pp: 411-425.

of composite wraps for deteriorating columns in north-east”, Infrastruc

3, 1994, pp:-199-206.

60

Page 72: Modeling of Fiber Reinforced Polymer confined concrete ...

13) Hoshikuma. J, Kawashima K., Nagaya K., Taylor A.W., “Stress-Strain Model for Confined Reinforced Concrete in Bridge Piers”, Journal of Structural Engineering, Vol.123, No.5, May 1997, pp: 624-633.

14)

ations”, Journal of Materials in Civil Engineering, Vol.9, No.4, Nov 1997, pp: 185-193.

15)

p: 471- 489.

).

3;

20) Lin H-J., Liao C-I, “Compressive strength of reinforced concrete column confined by

21) Liu, J., Foster, S.J., “Finite-Element Model for Confined Concrete Columns”, Journal

22) Mander J. B, Priestly M.J.N, Park R “Theoretical stress-strain model for confined

23)

; pp: 263-268.

for Construction, Vol.2, No.4, Nov 1998, pp: 175-185

26) g. Y,” Nonlinear Finite Element Modeling of Concrete

Confined by Fiber Composites”, Finite element analysis and design; the international

Karbhari. V. M, Gao. Y, “Composite Jacketed Concrete under Uniaxial Compression-Verification of Simple Design Equ

Lam. L, Teng. J.G, “Design – Oriented stress – strain model for FRP-confined concrete”, Construction and Building Materials, Vol. 17, 2003, p

16) Lam. L and Teng. J. G, “Strength Models for Fiber- Reinforced Plastic-Confined

Concrete”, Journal of Structural Engineering, May 2002, pp: 612- 623.

17) Li. G, "Experimental Study of FRP Confined Concrete Cylinders," Engineering Structures, 2005, (accepted).

18) Li. G, Maricherla. D, Singh. K, Pang. S. S and John. M, Effect of Fiber Orientation on

the Structural Behavior of FRP Wrapped Concrete Cylinders," Composite Structures, 2005 (accepted

19) Li G, Hedlund S, Pang SS, Alaywan W, Eggers J, and Abadie C. Repair of damaged

RC columns using fast curing FRP composites. Composite Part B: Engineering 200Vol.34, pp: 261-271.

composite material”, Composite Structures, 2003.

of Structural Engineering, Vol.124, No.9, Sep, 1998, pp: 1011-1017.

concrete”, Journal of Structural Engineering, ASCE, 1988; 114(8), pp: 1804- 1826.

Mirmiran A, Shahawy M, “A new concrete filled hollow FRP composite column” Composites: part B; 27 B, 1996

24) Mirmiran. A and Shahawy. M, “Behavior of Concrete Columns Confined by Fiber

Composites”, Journal of Structural Engineering, Vol.123, No.5, May 1997, pp: 583-590.

25) Mirmiran. A and Shahawy. M, Samaan M., Echary H.E., Mastrapa J C., Pico O., “

Effect of Column Parameters on FRP-Confined Concrete”, Journal of Composites

Mirmiran. A, Zagers. K, Wenqin

61

Page 73: Modeling of Fiber Reinforced Polymer confined concrete ...

journal of applied finite elements and computer aided engineering, 35(1), 2000, pp:-79-96.

27) Moran A. D, Pantelides C.P, “Stress-strain model for Fiber reinforced polymer

confined concrete”, Journal of Composites for construction, Nov, 2002, 6(4), pp: 233-240.

28) Nanni A, Bradford N.M, “FRP jacketed concrete under uniaxial compression”

Construction and Building Materials, 1995; 9(2); pp: 115-124.

29) Neville, A. M., “Properties of Concrete”, Pitman Publishing Inc., London, 1981.

30) Newman, K., and Newman, J.B., “Failure Theories and Design Criteria for Plain Concrete”, Proceedings, International Civil Engineering Materials Conference on Structure, Solid Mechanics and Engineering Design (Southampton, 1969), Wiley Interscience, New York, 1972, Part 2, pp: 963-995.

31) Parvin. A, Jamwal. A. J, “Effects of wrap thickness and ply configuration on

composite-confined concrete cylinders,” Composite Structures, 2004.

32) Popov. E. P, “Mechanics of Materials”, Prentice Hall, second edition, 1976.

33) Popovics s; “A numerical approach to complete stress-strain curves for concrete” Cement and Concrete Research, 3 (5), 1973, pp: 583-599.

34) Richard , R. M , and Abbott B. J, “Versatile elastic plastic stress-strain formula”,

Journal of Engineering Mechanics, 1975, 101(4); pp:-511-515.

35) Richart, F.E., Brandtzaeg, A., and Brown, R. L, “A study of failure of concrete under combined compressive stresses”. Bulletin No.185, 1928. Univ. of Illinois, Engineering Experimental Station, Urbana, III.

36) Rochette. P, Labossiere. P, “A plasticity approach for concrete columns confined with

composite materials, in: M.M. El-Badry (Ed.), Proceedings advanced Composite Materials in Bridges and Structures, CSCE, 1996, pp:-359-366.

37) Rochette. P, Labossiere. P, “Axial testing of rectangular column models confined with

composites”, Journal of Composites in Construction, 4 (3), 2000, pp:-129-136.

38) Saafi M, Tountaji H.A., “Behavior of concrete columns confined with fiber reinforced polymer tubes” ACI, Materials Journal 96(4), Jul/Aug 1999; pp: 500-509.

39) Sadaamantesh H, Ehsani M.R, Li M.W, “Strength and ductility of concrete columns

externally reinforced with fiber composite sheets”, ACI Structural Journal, 91(4), 1994, pp: 434-447.

62

Page 74: Modeling of Fiber Reinforced Polymer confined concrete ...

40) Samaan M, Mirmiran A, Shahawy M, “Model of concrete confined by fiber composites”, Journal of Structural Engineering, ASCE, 124, (1998), pp:-1025-1031.

41) Saatcioglu, M., Razvi, S.R., “Strength and ductility of confined concrete’, Journal of Structural Engineering, Vol. 118, No.6, 1992, pp: 1590-1607.

42) Spiegel. L., Limbrunner. G.F., “Reinforced Concrete Design”, 4th edition, Prentice Hall, Inc., New Jersey, 1998.

43) Spoelstra M. R, Monti G, “FRP confined concrete model”, Journal of composites for

construction, ASCE, 3 (3), Aug 1999, pp: 143-150.

44) Tegola, L.A., and Manni, D., “Experimental Investigation on concrete confined by fiber reinforced polymer and comparison with theoretical model”, International Symposium on Fiber Reinforced Polymer Reinforcement for Reinforced Concrete Structures., Michigan, 1999, pp: 249-254.

45) Tountaji H. A, “Stress-Strain characteristics of concrete columns externally confined

with advanced fiber composite sheets”, ACI Materials Journal, 96(3), 1999, pp:- 397-404.

46) Tountaji. H. A, Balaguru. P, “Durability characteristics of concrete columns wrapped

with fiber tow sheets”, Journal of materials in civil engineering, 1998, 10(1), 52-57.

47) Tsai, Stephen W., Thomas Hahn “Introduction to composite materials”, Westport, Conn.: Technomic Pub., c1980.

48) Vinson, J. R., Sierakowski, R. L., “The behavior of structures composed of composite

materials”. Martinus Nijhoff Publisher, Dordrecht, Netherlands.1986.

49) Willam, K. J., and Warnke, E. D., "Constitutive Model for the Triaxial Behavior of Concrete", Proceedings, International Association for Bridge and Structural Engineering, Vol. 19, ISMES, Bergamo, Italy, p. 174 (1975).

50) Xiao Y, Wu H., “Compressive behavior of concrete confined by carbon fiber composite

jackets”, Journal of Materials in civil engineering, 12(2), 2000, pp:-139-146.

63

Page 75: Modeling of Fiber Reinforced Polymer confined concrete ...

APPENDIX A: BOUNDARY CONDITIONS

> restart;

Boundary Condition (Eq: 4.29)

> sigz:=-(P/Ix)*r*sin(theta)*(l-z);

sigz := - P r sin( ) l - z( )

Ix

> Eq1:=subs(z=0,sigz);

Eq1 := - P r sin( ) l

Ix

> I1:=int(r^2*sin(theta)^2,r=0..a);

I1 := 1

3 sin( )

2 a

3

> I2:=int(I1,theta=0..2*Pi);

I2 := 1

3 a

3

> Eq2:=subs(Ix=I2,Eq1);

Eq2 := - 3 P r sin( ) l

a3

> Eq3:=int(Eq2,r=0..a);

Eq3 := - 3 P sin( ) l

2 a

Boundary Condition at z=0

> Bc1:=int(Eq3,theta=0..2*Pi);Bc1 := 0

> Eq4:=subs(z=l,sigz);Eq4 := 0

> Eq5:=int(Eq4,r=0..a);Eq5 := 0

Boundary Condition at z=l64

Page 76: Modeling of Fiber Reinforced Polymer confined concrete ...

> Bc2:=int(Eq5,theta=0..2*Pi);Bc2 := 0

>

65

Page 77: Modeling of Fiber Reinforced Polymer confined concrete ...

> restart;

Boundary Condition from Eq: 4.30

> ttz:=((P/Ix)*((3+2*nu)/(1+nu))*(1/8)*(a^2-(((1-2*nu)/(3+2*nu))*(r^2*cos(theta)^2))-r^2*sin(theta)^2)*(cos(theta)))-((P/Ix)*((1+2*nu)/(1+nu))*(1/4)*r^2*sin(theta)*cos(theta))*(-sin(theta));

ttz :=

P 3 + 2 ( ) a2 -

1 - 2 ( ) r2 cos( )

2

3 + 2 - r

2 sin( )

2 cos( )

8 Ix 1 + ( ) +

P 1 + 2 ( ) r2 sin( )

2 cos( )

4 Ix 1 + ( )

> trz:=((P/Ix)*((3+2*nu)/(1+nu))*(1/8)*(a^2-(((1-2*nu)/(3+2*nu))*(r^2*cos(theta)^2))-r^2*sin(theta)^2)*(sin(theta)))-((P/Ix)*((1+2*nu)/(1+nu))*(1/4)*r^2*sin(theta)*cos(theta))*(cos(theta));

trz :=

P 3 + 2 ( ) a2 -

1 - 2 ( ) r2 cos( )

2

3 + 2 - r

2 sin( )

2 sin( )

8 Ix 1 + ( ) -

P 1 + 2 ( ) r2 sin( ) cos( )

2

4 Ix 1 + ( )

>

> Eq1:=trz*sin(theta)+ttz*cos(theta);

Eq1 :=

P 3 + 2 ( ) a2 -

1 - 2 ( ) r2 cos( )

2

3 + 2 - r

2 sin( )

2 sin( )

8 Ix 1 + ( ) -

P 1 + 2 ( ) r2 sin( ) cos( )

2

4 Ix 1 + ( )

sin( )

+

P 3 + 2 ( ) a2 -

1 - 2 ( ) r2 cos( )

2

3 + 2 - r

2 sin( )

2 cos( )

8 Ix 1 + ( )

66

Page 78: Modeling of Fiber Reinforced Polymer confined concrete ...

+ P 1 + 2 ( ) r

2 sin( )

2 cos( )

4 Ix 1 + ( ) cos( )

> I1:=int(r^2*sin(theta)^2,r=0..a);

I1 := 1

3 sin( )

2 a

3

> I2:=int(I1,theta=0..2*Pi);

I2 := 1

3 a

3

> Eq2:=subs(Ix=I2,Eq1);

Eq2 :=

3 P 3 + 2 ( ) a2 -

1 - 2 ( ) r2 cos( )

2

3 + 2 - r

2 sin( )

2 sin( )

8 a3 1 + ( )

- 3 P 1 + 2 ( ) r

2 sin( ) cos( )

2

4 a3 1 + ( )

sin( )

+

3 P 3 + 2 ( ) a2 -

1 - 2 ( ) r2 cos( )

2

3 + 2 - r

2 sin( )

2 cos( )

8 a3 1 + ( )

+ 3 P 1 + 2 ( ) r

2 sin( )

2 cos( )

4 a3 1 + ( )

cos( )

> Eq3:=int(Eq2,r=0..a);67

Page 79: Modeling of Fiber Reinforced Polymer confined concrete ...

Eq3 := 1

3

3 P 3 + 2 ( ) - 1 - 2 ( ) cos( )

2

3 + 2 - sin( )

2 sin( )

8 a3 1 + ( )

- 3 P 1 + 2 ( ) sin( ) cos( )

2

4 a3 1 + ( )

sin( )

+

3 P 3 + 2 ( ) - 1 - 2 ( ) cos( )

2

3 + 2 - sin( )

2 cos( )

8 a3 1 + ( )

+ 3 P 1 + 2 ( ) sin( )

2 cos( )

4 a3 1 + ( )

cos( ) a3 +

3 P 3 + 2 ( ) sin( )2

8 1 + ( ) +

3 P 3 + 2 ( ) cos( )2

8 1 + ( )

Boundary Condition at z=l

> Bc1:int(Eq3,theta=0..2*Pi);

P

68

Page 80: Modeling of Fiber Reinforced Polymer confined concrete ...

> restart;

Boundary Condition from Eq: 4.31

> ttz:=((P/Ix)*((3+2*nu)/(1+nu))*(1/8)*(a^2-(((1-2*nu)/(3+2*nu))*(r^2*cos(theta)^2))-r^2*sin(theta)^2)*(cos(theta)))-((P/Ix)*((1+2*nu)/(1+nu))*(1/4)*r^2*sin(theta)*cos(theta))*(-sin(theta));

ttz :=

P 3 + 2 ( ) a2 -

1 - 2 ( ) r2 cos( )

2

3 + 2 - r

2 sin( )

2 cos( )

8 Ix 1 + ( ) +

P 1 + 2 ( ) r2 sin( )

2 cos( )

4 Ix 1 + ( )

> trz:=((P/Ix)*((3+2*nu)/(1+nu))*(1/8)*(a^2-(((1-2*nu)/(3+2*nu))*(r^2*cos(theta)^2))-r^2*sin(theta)^2)*(sin(theta)))-((P/Ix)*((1+2*nu)/(1+nu))*(1/4)*r^2*sin(theta)*cos(theta))*(cos(theta));

trz :=

P 3 + 2 ( ) a2 -

1 - 2 ( ) r2 cos( )

2

3 + 2 - r

2 sin( )

2 sin( )

8 Ix 1 + ( ) -

P 1 + 2 ( ) r2 sin( ) cos( )

2

4 Ix 1 + ( )

> Eq1:=trz*cos(theta)-ttz*sin(theta);

Eq1 :=

P 3 + 2 ( ) a2 -

1 - 2 ( ) r2 cos( )

2

3 + 2 - r

2 sin( )

2 sin( )

8 Ix 1 + ( ) -

P 1 + 2 ( ) r2 sin( ) cos( )

2

4 Ix 1 + ( )

cos( )

-

P 3 + 2 ( ) a2 -

1 - 2 ( ) r2 cos( )

2

3 + 2 - r

2 sin( )

2 cos( )

8 Ix 1 + ( )

69

Page 81: Modeling of Fiber Reinforced Polymer confined concrete ...

+ P 1 + 2 ( ) r

2 sin( )

2 cos( )

4 Ix 1 + ( ) sin( )

> I1:=int(r^2*sin(theta)^2,r=0..a);

I1 := 1

3 sin( )

2 a

3

> I2:=int(I1,theta=0..2*Pi);

I2 := 1

3 a

3

> Eq2:=subs(Ix=I2,Eq1);

Eq2 :=

3 P 3 + 2 ( ) a2 -

1 - 2 ( ) r2 cos( )

2

3 + 2 - r

2 sin( )

2 sin( )

8 a3 1 + ( )

- 3 P 1 + 2 ( ) r

2 sin( ) cos( )

2

4 a3 1 + ( )

cos( )

-

3 P 3 + 2 ( ) a2 -

1 - 2 ( ) r2 cos( )

2

3 + 2 - r

2 sin( )

2 cos( )

8 a3 1 + ( )

+ 3 P 1 + 2 ( ) r

2 sin( )

2 cos( )

4 a3 1 + ( )

sin( )

> Eq3:=int(Eq2,r=0..a);

70

Page 82: Modeling of Fiber Reinforced Polymer confined concrete ...

Eq3 := 1

3

3 P 3 + 2 ( ) - 1 - 2 ( ) cos( )

2

3 + 2 - sin( )

2 sin( )

8 a3 1 + ( )

- 3 P 1 + 2 ( ) sin( ) cos( )

2

4 a3 1 + ( )

cos( )

-

3 P 3 + 2 ( ) - 1 - 2 ( ) cos( )

2

3 + 2 - sin( )

2 cos( )

8 a3 1 + ( )

+ 3 P 1 + 2 ( ) sin( )

2 cos( )

4 a3 1 + ( )

sin

( ) a3

Boundary Condition at z=l

> Bc1:int(Eq3,theta=0..2*Pi);0

71

Page 83: Modeling of Fiber Reinforced Polymer confined concrete ...

> restart;

Boundary Condition from Eq: 4.32

> sigz:=-(P/Ix)*r*sin(theta)*(l-z);

sigz := - P r sin( ) l - z( )

Ix

> Eq1:=-sigz*r*sin(theta);

Eq1 := P r

2 sin( )

2 l - z( )

Ix

> Eq2:=subs(z=0,Eq1);

Eq2 := P r

2 sin( )

2 l

Ix

> I1:=int(r^2*sin(theta)^2,r=0..a);

I1 := 1

3 sin( )

2 a

3

> I2:=int(I1,theta=0..2*Pi);

I2 := 1

3 a

3

> Eq3:=subs(Ix=I2,Eq2);

Eq3 := 3 P r

2 sin( )

2 l

a3

> Eq4:=int(Eq3,r=0..a);

Eq4 := P sin( )

2 l

Boundary Condition at z=0

> Bc1:=int(Eq4,theta=0..2*Pi);Bc1 := P l

> Eq5:=subs(z=l,Eq1);Eq5 := 0

> Eq6:=int(Eq5,r=0..a);Eq6 := 0

72

Page 84: Modeling of Fiber Reinforced Polymer confined concrete ...

Boundary Condition at z=l

> Bc2:=int(Eq6,theta=0..2*Pi);Bc2 := 0

73

Page 85: Modeling of Fiber Reinforced Polymer confined concrete ...

> restart;

Boundary Conditions from Eq: 4.33

> sigz:=-(P/Ix)*r*sin(theta)*(l-z);

sigz := - P r sin( ) l - z( )

Ix

> Eq1:=sigz*r*cos(theta);

Eq1 := - P r

2 sin( ) l - z( ) cos( )

Ix

> Eq2:=subs(z=0,Eq1);

Eq2 := - P r

2 sin( ) l cos( )

Ix

> I1:=int(r^2*sin(theta)^2,r=0..a);

I1 := 1

3 sin( )

2 a

3

> I2:=int(I1,theta=0..2*Pi);

I2 := 1

3 a

3

> Eq3:=subs(Ix=I2,Eq2);

Eq3 := - 3 P r

2 sin( ) l cos( )

a3

> Eq4:=int(Eq3,r=0..a);

Eq4 := - P sin( ) l cos( )

Boundary Condition at z=0

> Bc1:=int(Eq4,theta=0..2*Pi);Bc1 := 0

> Eq5:=subs(z=l,Eq1);Eq5 := 0

> Eq6:=int(Eq5,r=0..a);

74

Page 86: Modeling of Fiber Reinforced Polymer confined concrete ...

Eq6 := 0

Boundary Condition at z=l

> Bc2:=int(Eq6,theta=0..2*Pi);Bc2 := 0

75

Page 87: Modeling of Fiber Reinforced Polymer confined concrete ...

> restart;

Boundary Condition from Eq: 4.34

> ttz:=((P/Ix)*((3+2*nu)/(1+nu))*(1/8)*(a^2-(((1-2*nu)/(3+2*nu))*(r^2*cos(theta)^2))-r^2*sin(theta)^2)*(cos(theta)))-((P/Ix)*((1+2*nu)/(1+nu))*(1/4)*r^2*sin(theta)*cos(theta))*(-sin(theta));

ttz :=

P 3 + 2 ( ) a2 -

1 - 2 ( ) r2 cos( )

2

3 + 2 - r

2 sin( )

2 cos( )

8 Ix 1 + ( ) +

P 1 + 2 ( ) r2 sin( )

2 cos( )

4 Ix 1 + ( )

> Eq1:=ttz*r;

Eq1 :=

P 3 + 2 ( ) a2 -

1 - 2 ( ) r2 cos( )

2

3 + 2 - r

2 sin( )

2 cos( )

8 Ix 1 + ( )

+ P 1 + 2 ( ) r

2 sin( )

2 cos( )

4 Ix 1 + ( ) r

> I1:=int(r^2*sin(theta)^2,r=0..a);

I1 := 1

3 sin( )

2 a

3

> I2:=int(I1,theta=0..2*Pi);

I2 := 1

3 a

3

> Eq2:=subs(Ix=I2,Eq1);

Eq2 :=

3 P 3 + 2 ( ) a2 -

1 - 2 ( ) r2 cos( )

2

3 + 2 - r

2 sin( )

2 cos( )

8 a3 1 + ( )

76

Page 88: Modeling of Fiber Reinforced Polymer confined concrete ...

+ 3 P 1 + 2 ( ) r

2 sin( )

2 cos( )

4 a3 1 + ( )

r

> Eq3:=int(Eq2,r=0..a);

Eq3 := 1

4

3 P 3 + 2 ( ) - 1 - 2 ( ) cos( )

2

3 + 2 - sin( )

2 cos( )

8 a3 1 + ( )

+ 3 P 1 + 2 ( ) sin( )

2 cos( )

4 a3 1 + ( )

a4 +

3 P a 3 + 2 ( ) cos( )

16 1 + ( )

Boundary Condition at z=l

> Bc1:=int(Eq3,theta=0..2*Pi);Bc1 := 0

77

Page 89: Modeling of Fiber Reinforced Polymer confined concrete ...

> restart;

Boundary Condition from Eq:4.36

> trz:=((P/Ix)*((3+2*nu)/(1+nu))*(1/8)*(a^2-(((1-2*nu)/(3+2*nu))*(r^2*cos(theta)^2))-r^2*sin(theta)^2)*(sin(theta)))-((P/Ix)*((1+2*nu)/(1+nu))*(1/4)*r^2*sin(theta)*cos(theta))*(cos(theta));

trz :=

P 3 + 2 ( ) a2 -

1 - 2 ( ) r2 cos( )

2

3 + 2 - r

2 sin( )

2 sin( )

8 Ix 1 + ( ) -

P 1 + 2 ( ) r2 sin( ) cos( )

2

4 Ix 1 + ( )

> Eq1:=subs(r=a,trz);

Eq1 :=

P 3 + 2 ( ) a2 -

1 - 2 ( ) a2 cos( )

2

3 + 2 - a

2 sin( )

2 sin( )

8 Ix 1 + ( ) -

P 1 + 2 ( ) a2 sin( ) cos( )

2

4 Ix 1 + ( )

> I1:=int(r^2*sin(theta)^2,r=0..a);

I1 := 1

3 sin( )

2 a

3

> I2:=int(I1,theta=0..2*Pi);

I2 := 1

3 a

3

> Eq2:=subs(Ix=I2,Eq1);

Eq2 :=

3 P 3 + 2 ( ) a2 -

1 - 2 ( ) a2 cos( )

2

3 + 2 - a

2 sin( )

2 sin( )

8 a3 1 + ( )

- 3 P 1 + 2 ( ) sin( ) cos( )

2

4 a 1 + ( )

Boundary condition at r = R

78

Page 90: Modeling of Fiber Reinforced Polymer confined concrete ...

> Bc:=simplify(%);Bc := 0

79

Page 91: Modeling of Fiber Reinforced Polymer confined concrete ...

AP NDIX TE D T E Table No.1 Summary of t n onc str ess No

Number of laye

M

f M

PE B: ST A ABAS

he co fined c rete ength for thickn =0.1 mm

. t mm

rs

cf MPa

cE MPa

ff Pa

fE MPa

lf MPa

cc Pa c

lff

k

1 0.1 1 8.27 13611 200 4300 0.263158 2 0.031821 -23.8262 0.1 1 13.7 17518 300 8925 0.394737 4 0.028813 -24.57333 0.1 1 20.6 21482 400 11900 0.526316 6 0.025549 -27.744 0.1 1 27.5 24820 500 39625 0.657895 8 0.023923 -29.645 0.1 1 34.4 27760 600 43150 0.789474 10 0.02295 -30.90676 0.1 1 48.2 32859 700 47225 0.921053 14 0.019109 -37.13147 0.1 1 55.1 35133 800 77700 1.052632 16 0.019104 -37.1458 0.1 1 68.9 39287 900 95525 1.184211 20 0.017187 -41.29339 0.1 1 75.8 41207 1000 116100 1.315789 20 0.017359 -42.408

10 0.1 1 89.6 44801 1125 128100 1.480263 22 0.016521 -45.667611 0.1 1 96.5 46494 1250 162650 1.644737 24 0.017044 -44.0812 0.1 1 110.3 49708 1375 179600 1.809211 26 0.016403 -46.594913 0.1 1 117.2 51239 1500 246050 1.973684 27 0.01684 -45.701314 0.1 1 124.1 52725 1750 422250 2.302632 27 0.018555 -42.169115 0.1 1 131 54171 2000 465500 2.631579 28 0.020088 -39.14

Table No.2 Summary of the confined c e st h ness

N m

Numbe of laye

MPa

MPa

MPa

oncret rengt for thick =0.25 mm

o. t m

r rs

f c E c MPa

f f E f

MPa f l MPa

ccf

cfl

f k

1 0. 25 1 8.27 13611 200 4300 0.657895 2 0.079552 -9.53042 0. 25 1 13.7 17111 300 8925 0.986842 5 0.072032 -8.8163 0. 25 1 20.6 21482 400 11900 1.315789 9 0.063873 -8.8164 0. 25 1 27.5 24820 500 39625 1.644737 10 0.059809 -10.645 0. 25 1 34.4 27760 600 43150 1.973684 10 0.057375 -12.36276 0. -25 1 48.2 32859 700 47225 2.302632 12 0.047772 15.72117 0. 25 1 55.1 35133 800 77700 2.631579 16 0.04776 -14.8588 0. 25 1 68.9 39287 900 95525 2.960526 20 0.042968 -16.51739 0. 25 1 75.8 41207 1000 116100 3.289474 20 0.043397 -16.9632

10 0. -25 1 89.6 44801 1125 128100 3.700658 22 0.041302 18.26711 0.25 1 96.5 46494 1250 162650 4.111842 25 0.04261 -17.388812 0.25 1 110.3 49708 1375 179600 4.523026 25 0.041007 -18.859113 0.25 1 117.2 51239 1500 246050 4.934211 28 0.042101 -18.077914 0.25 1 124.1 52725 1750 422250 5.756579 28 0.046387 -16.693915 0.25 1 131 54171 2000 465500 6.578947 30 0.050221 -15.352

80

Page 92: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No.3 Summary of the confined concrete strength for thickness =0.5 mm No. t

mm Number of layers

c kf MPa

cE MPa

ff MPa

fE MPa

lf MPa

ccf

c

lff

MPa

1 0.5 1 8.27 13611 200 4300 1.315789 10 0.159104 1.31482 0.5 1 13.7 17111 300 8925 1.973684 19 0.144065 2.6853333 0.5 1 20.6 21482 400 11900 2.631579 22 0.127747 0.5324 0.5 1 27.5 24820 500 39625 3.289474 32 0.119617 1.3685 0.5 1 34.4 27760 600 43150 3.947368 40 0.114749 1.4186676 0.5 1 48.2 32859 700 47225 4.605263 47 0.095545 -0.260577 0.5 1 55.1 35133 800 77700 5.263158 68 0.09552 2.4518 0.5 1 68.9 39287 900 95525 5.921053 80 0.085937 1.8746679 0.5 1 75.8 41207 1000 116100 6.578947 90 0.086794 2.1584

10 0.5 1 89.6 44801 1125 128100 7.401316 100 0.082604 1.40515611 0.5 1 96.5 46494 1250 162650 8.223684 119 0.08522 2.73612 0.5 1 110.3 49708 1375 179600 9.046053 124 0.082013 1.51447313 0.5 1 117.2 51239 1500 246050 9.868421 127 0.084202 0.99306714 0.5 1 124.1 52725 1750 422250 11.51316 135 0.092773 0.94674315 0.5 1 131 54171 2000 465500 13.15789 149 0.100442 1.368

Tabl . o e n c cre e e gth th ckn s 0.75 mm No.

mNumber of laye MPa MPa

MPa

e No 4 Summary f th confi ed on t str n for i es =

t k m rs

cf cE MPa

ff fE MPa

lf MPa

ccf

cflf

1 0. 1 1.175 1 8.27 13611 200 4300 1.973684 0.5 0.238656 298672 0.75 1 13.7 17111 300 8925 2.960526 20 0.216097 2.1283 0.75 1 20.6 21482 400 11900 3.947368 31 0.19162 2.6346674 0.75 1 27.5 24820 500 39625 4.934211 40 0.179426 2.5333335 0.75 1 34.4 27760 600 43150 5.921053 51 0.172124 2.8035566 0. 2.275 1 48.2 32859 700 47225 6.907895 64 0.143317 872387 0.75 1 55.1 35133 800 77700 7.894737 74 0.14328 2.3948 0.75 1 68.9 39287 900 95525 8.881579 82 0.128905 1.4749639 0. 175 1 75.8 41207 1000 116100 9.868421 94 0.13019 .844267

10 0.75 1 89.6 44801 1125 128100 11.10197 102 0.123906 1.11691911 0.75 1 96.5 46494 1250 162650 12.33553 113 0.127829 1.337612 0.75 1 110.3 49708 1375 179600 13.56908 129 0.12302 1.37813313 0. 1 1.275 1 17.2 51239 1500 246050 14.80263 135 0.126302 0248914 0.75 1 124.1 52725 1750 422250 17.26974 140 0.13916 0.92068615 0.75 1 131 54171 2000 465500 19.73684 145 0.150663 0.709333

81

Page 93: Modeling of Fiber Reinforced Polymer confined concrete ...

Table of e on ed co r te en h th ckn = mm

Table No.6 Summary o nfined c e strength kness = 1.5 mm No.

mNumbeof laye

M

M

No.5 Summary th c fin nc e str gt for i ess 1

f the co oncret for thic

t m

r rs

f cMPa

E c MPa

ff Pa

fE MPa

f l MPa

ccf Pa cf

l f k

1 1.5 1 8.27 13611 200 4300 3.947368 12 0.477312 0.9449332 1.5 1 13.7 17111 300 8925 5.921053 21 0.432194 1.2328893 1.5 1 20.6 21482 400 11900 7.894737 25 0.38324 0.5573334 1.5 1 27.5 24820 500 39625 9.868421 30 0.358852 0.2533335 1 0..5 1 34.4 27760 600 43150 11.84211 36 0.344247 1351116 1.5 1 48.2 32859 700 47225 13.81579 50 0.286635 0.1302867 1.5 1 55.1 35133 800 77700 15.78947 66 0.28656 0.6903338 1.5 1 68.9 39287 900 95525 17.76316 72 0.257811 0.1745199 1.5 1 75.8 41207 1000 116100 19.73684 89 0.260381 0.6688

10 1.5 1 89.6 44801 1125 128100 22.20395 119 0.247812 1.32408911 1 1.5 1 96.5 46494 1250 162650 24.67105 122 0.255659 .033612 1.5 1 110.3 49708 1375 179600 27.13816 125 0.24604 0.54167313 1.5 1 117.2 51239 1500 246050 29.60526 127 0.252605 0.33102214 1.5 1 124.1 52725 1750 422250 34.53947 133 0.27832 0.25767615 1.5 1 131 54171 2000 465500 39.47368 137 0.301326 0.152

No m

Numberof layers

M

M

M

MP

. t m

cf Pa

cE MPa

f kPa

f f EPa

lf MPa

ccf a c

lf

f

1 1 1 8 1 2 2 1 0 1 .27 3611 00 4300 .631579 3 .318208 .79742 1 1 1 1 3 3 2 0 2 3.7 7111 00 8925 .947368 4 .288129 .6093333 1 1 2 2 4 1 5 3 0 0.6 1482 00 1900 .263158 7 .255493 3.1164 1 1 2 2 5 3 6 4 0 7.5 4820 00 9625 .578947 9 .239234 3.2685 1 1 3 2 6 4 7 5 0 2 4.4 7760 00 3150 .894737 2 .229498 .2293336 1 1 4 3 9 6 1 8.2 2859 700 47225 .210526 1 0.19109 .3897147 1 1 5 3 1 5.1 5133 800 77700 0.52632 76 0.19104 1.98558 1 1 6 3 1 0 8.9 9287 900 95525 1.84211 95 .171874 2.2049 1 1 4 1 1 1 1 0 75.8 1207 000 16100 3.15789 03 .173587 2.0672

10 1 1 4 1 1 1 1 0 1 89.6 4801 125 28100 4.80263 07 .165208 .17546711 1 1 4 1 1 1 1 0 96.5 6494 250 62650 6.44737 10 .170439 0.820812 1 1 1 4 1 1 1 1 0 0 10.3 9708 375 79600 8.09211 21 .164026 .59141813 1 1 117.2 5123 1500 2460 19.736 126 0.1684 0.44589 50 84 03 6714 1 1 124.1 52725 1750 422250 23.02632 135 0.185546 0.47337115 1 1 131 54171 2000 465500 26.31579 140 0.200884 0.342

82

Page 94: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No.7 Summary of the confined concrete strength fo 2 mm

able No. 8 Summary of the confined concrete strength for thickness =2.5 mm

No. mm of layers M M

r thickness =

T

t Number cf MPa

cE MPa

ff Pa

fE Pa

lf MPa

ccf MPa cf

lf k

1 2 0..5 1 8.27 13611 200 4300 6.578947 12 0.79552 566962 2 0.7.5 1 13.7 17111 300 8925 9.868421 21 0.720323 397333 2 0.5 1 20.6 21482 400 11900 13.15789 33 0.638733 .94244 2 0.5 1 27.5 24820 500 39625 16.44737 37 0.598086 .57765 2.5 1 34.4 27760 600 43150 19.73684 43 0.573745 0.4357336 2.5 1 48.2 32859 700 47225 23.02632 56 0.477724 0.3387437 2.5 1 55.1 35133 800 77700 26.31579 68 0.477601 0.49028 2 0..5 1 68.9 39287 900 95525 29.60526 84 0.429685 5100449 2.5 1 75.8 41207 1000 116100 32.89474 96 0.433968 0.61408

10 2 0..5 1 89.6 44801 1125 128100 37.00658 110 0.41302 55125311 2.5 1 96.5 46494 1250 162650 41.11842 117 0.426098 0.4985612 2.5 1 110.3 49708 1375 179600 45.23026 119 0.410066 0.19234913 2.5 1 117.2 51239 1500 246050 49.34211 126 0.421008 0.17834714 2 1 0..5 1 24.1 52725 1750 422250 57.56579 133 0.463866 15460615 2.5 1 131 54171 2000 465500 65.78947 142 0.50221 0.1672

MPa MNo. t

mm Number of layers

cf cE MPa

ff Pa

fE MPa

lf MPa

ccf MPa

k

cflf

1 2 1 8.27 13611 200 4300 5.263158 15 0.636416 1.27872 2 1 13.7 17518 300 8925 7.894737 22 0.576258 1.0513333 2 1 20.6 21482 400 11900 10.52632 40 0.510986 1.8434 2 1 27.5 24820 500 39625 13.15789 43 0.478469 1.1785 2 1 34.4 27760 600 43150 15.78947 55 0.458996 1.3046676 2 1 48.2 32859 700 47225 18.42105 60 0.38218 0.6405717 2 1 55.1 35133 800 77700 21.05263 74 0.38208 0.897758 2 1 68.9 39287 900 95525 23.68421 86 0.343748 0.7229 2 1 75.8 41207 1000 116100 26.31579 110 0.347174 1.2996

10 2 1 89.6 44801 1125 128100 29.60526 117 0.330416 0.92551111 2 1 96.5 46494 1250 162650 32.89474 125 0.340878 0.866412 2 1 110.3 49708 1375 179600 36.18421 127 0.328053 0.46152713 2 1 117.2 51239 1500 246050 39.47368 132 0.336806 0.37493314 2 1 124.1 52725 1750 422250 46.05263 137 0.371093 0.28011415 2 1 131 54171 2000 465500 52.63158 140 0.401768 0.171

83

Page 95: Modeling of Fiber Reinforced Polymer confined concrete ...

Tabl . S o con ine c c ete ren th ickn s = mm

No. m of laye M M M

e No 9 ummary f the f d on r st g for th es 3

t m

Number rs

cf MPa

cE MPa

ff Pa

fE Pa

lf MPa

ccf Pa

k

cflf

1 3 1 8.27 13611 200 4300 7.894737 18 0.954624 1.2324672 3 1 13.7 17518 300 8925 11.84211 26 0.864387 1.0386673 3 1 20.6 21482 400 11900 15.78947 40 0.766479 1.2286674 3 1 27.5 24820 500 39625 19.73684 44 0.717703 0.8365 3 1 34.4 27760 600 43150 23.68421 51 0.688494 0.7008896 3 1 48.2 32859 700 47225 27.63158 63 0.573269 0.5356197 3 1 55.1 35133 800 77700 31.57895 81 0.573121 0.8201678 3 1 68.9 39287 900 95525 35.52632 98 0.515621 0.8191119 3 1 75.8 41207 1000 116100 39.47368 116 0.520761 1.0184

10 3 1 89.6 44801 1125 128100 44.40789 120 0.495624 0.68456311 3 1 96.5 46494 1250 162650 49.34211 115 0.511317 0.37493312 3 1 110.3 49708 1375 179600 54.27632 119 0.492079 0.16029113 3 1 117.2 51239 1500 246050 59.21053 130 0.505209 0.21617814 3 1 124.1 52725 1750 422250 69.07895 140 0.556639 0.23017115 3

1 131 54171 2000 465500 78.94737 155 0.602652 0.304

Table No.10 Summary of the confined concrete strength for thickness = 3.5 mm

No. t mm

Number of layers

cf MPa

cE MPa MPa MPa

ff MPa

fE lf MPa

ccf k

c

lff

1 3.5 1 8.27 13611 200 4300 9.210526 15 1.113727 0.7306862 3.5 1 13.7 17111 300 8925 13.81579 22 1.008452 0.6007623 3 0..5 1 20.6 21482 400 11900 18.42105 35 0.894226 7817144 3 1..5 1 27.5 24820 500 39625 23.02632 60 0.837321 4114295 3 1..5 1 34.4 27760 600 43150 27.63158 65 0.803244 1074296 3 0..5 1 48.2 32859 700 47225 32.23684 70 0.668814 6762457 3.5 1 55.1 35133 800 77700 36.84211 73 0.668641 0.4858578 3.5 1 68.9 39287 900 95525 41.44737 77 0.601558 0.1954299 3.5 1 75.8 41207 1000 116100 46.05263 93 0.607555 0.373486

10 3.5 1 89.6 44801 1125 128100 51.80921 100 0.578228 0.20073711 3.5 1 96.5 46494 1250 162650 57.56579 115 0.596537 0.32137112 3.5 1 110.3 49708 1375 179600 63.32237 125 0.574092 0.23214513 3.5 1 117.2 51239 1500 246050 69.07895 136 0.589411 0.27215214 3 52725 1750 422250 80.59211 140 0.649413 9.5 1 124.1 0.197215 3.5 1 131 54171 2000 465500 92.10526 150 0.703094 0.206286

84

Page 96: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No.11 Summary of the confined concrete strength for thickness =4 mm No.

mm Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t cf cE ff fE lf ccf

c

lff

k

1 4 1 8.27 13611 200 4300 10.52632 19.9 1.272831 1.104852 4 1 13.7 17111 300 8925 15.78947 32 1.152516 1.1593 4 1 20.6 21482 400 11900 21.05263 41 1.021972 0.9694 4 1 27.5 24820 500 39625 26.31579 55 0.956938 1.0455 4 1 34.4 27760 600 43150 31.57895 65 0.917993 0.9696 4 1 48.2 32859 700 47225 36.84211 80 0.764359 0.8631437 4 1 55.1 35133 800 77700 42.10526 89 0.764161 0.8051258 4 1 68.9 39287 900 95525 47.36842 89 0.687495 0.4243339 4 1 75.8 41207 1000 116100 52.63158 95 0.694348 0.3648

10 4 1 89.6 44801 1125 128100 59.21053 103 0.660832 0.22631111 4 1 96.5 46494 1250 162650 65.78947 110 0.681756 0.205212 4 1 110.3 49708 1375 179600 72.36842 122 0.656105 0.16167313 4 1 117.2 51239 1500 246050 78.94737 126 0.673612 0.11146714 4 1 124.1 52725 1750 422250 92.10526 180 0.742186 0.60691415 4 1 131 54171 2000 465500 105.2632 200 0.803536 0.6555

Table No.12 Summary of the confined concrete strength for thickness =4.5 mm

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t cf cE ff fE lf ccf

c

lff

k

1 4.5 1 8.27 13611 200 4300 11.84211 30 1.431935 1.8349782 4.5 1 13.7 17518 300 8925 17.76316 55 1.296581 2.3250373 4.5 1 20.6 21482 400 11900 23.68421 60 1.149719 1.6635564 4.5 1 27.5 24820 500 39625 29.60526 80 1.076555 1.7733335 4.5 1 34.4 27760 600 43150 35.52632 95 1.032742 1.7057786 4.5 1 48.2 32859 700 47225 41.44737 98 0.859904 1.2015247 4.5 1 55.1 35133 800 77700 47.36842 100 0.859681 0.9478898 4.5 1 68.9 39287 900 95525 53.28947 107 0.773432 0.7149639 4.5 1 75.8 41207 1000 116100 59.21053 112 0.781142 0.611378

10 4.5 1 89.6 44801 1125 128100 66.61184 115 0.743436 0.38131411 4.5 1 96.5 46494 1250 162650 74.01316 120 0.766976 0.31751112 4.5 1 110.3 49708 1375 179600 81.41447 129 0.738119 0.22968913 4.5 1 117.2 51239 1500 246050 88.81579 136 0.757814 0.21167414 4.5 1 124.1 52725 1750 422250 103.6184 143 0.834959 0.182415 4.5 1 131 54171 2000 465500 118.4211 172 0.903978 0.346222

85

Page 97: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No.13 Summary of the confined concrete strength for thickness =5 mm

Table No.14 Summary of the confined concrete strength for thickness =5.5 mm

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t cf cE ff fE lf ccf

c

lff

k

1 5 1 8.27 13611 200 4300 13.15789 41 1.591039 2.487482 5 1 13.7 17111 300 8925 19.73684 57 1.440645 2.1938673 5 1 20.6 21482 400 11900 26.31579 69 1.277466 1.83924 5 1 27.5 24820 500 39625 32.89474 76 1.196172 1.47445 5 1 34.4 27760 600 43150 39.47368 80 1.147491 1.15526 5 1 48.2 32859 700 47225 46.05263 93 0.955449 0.97287 5 1 55.1 35133 800 77700 52.63158 104 0.955201 0.92918 5 1 68.9 39287 900 95525 59.21053 117 0.859369 0.8123569 5 1 75.8 41207 1000 116100 65.78947 124 0.867935 0.73264

10 5 1 89.6 44801 1125 128100 74.01316 137 0.82604 0.64042711 5 1 96.5 46494 1250 162650 82.23684 145 0.852195 0.5897612 5 1 110.3 49708 1375 179600 90.46053 150 0.820132 0.43886513 5 1 117.2 51239 1500 246050 98.68421 163 0.842015 0.46410714 5 1 124.1 52725 1750 422250 115.1316 172 0.927732 0.41604615 5 1 131 54171 2000 465500 131.5789 210 1.004419 0.6004

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

1 5.5 1 8.27 13611 200 4300 14.47368 47 1.750143 2.6758912 5.5 1 13.7 17111 300 8925 21.71053 65 1.58471 2.3629093 5.5 1 20.6 21482 400 11900 28.94737 71 1.405212 1.7410914 5.5 1 27.5 24820 500 39625 36.18421 86 1.315789 1.6167275 5.5 1 34.4 27760 600 43150 43.42105 99 1.26224 1.4877586 5.5 1 48.2 32859 700 47225 50.65789 102 1.050994 1.0620267 5.5 1 55.1 35133 800 77700 57.89474 105 1.050721 0.8619098 5.5 1 68.9 39287 900 95525 65.13158 109 0.945306 0.6156779 5.5 1 75.8 41207 1000 116100 72.36842 110 0.954729 0.472582

10 5.5 1 89.6 44801 1125 128100 81.41447 110 0.908644 0.2505711 5.5 1 96.5 46494 1250 162650 90.46053 115 0.937415 0.20450912 5.5 1 110.3 49708 1375 179600 99.50658 122 0.902145 0.1175813 5.5 1 117.2 51239 1500 246050 108.5526 127 0.926217 0.09027914 5.5 1 124.1 52725 1750 422250 126.6447 145 1.020506 0.16502915 5.5 1 131 54171 2000 465500 144.7368 200 1.104861 0.476727

86

Page 98: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No.15 Summary of the confined concrete strength for thickness =6 mm

Table No.16 Summary of the confined concrete strength for unconfined concrete strength = 8.27MPa No.

mm Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t cf cE ff fE lf ccf

c

lff

k

1 0.1 1 8.27 13611 200 4300 0.263158 2 0.031821 -23.8262 0.25 1 8.27 13611 300 8925 0.986842 20 0.119328 11.88643 0.5 1 8.27 13611 400 11900 2.631579 27 0.318208 7.11744 0.75 1 8.27 13611 500 39625 4.934211 30.9 0.59664 4.5863475 1 1 8.27 13611 600 43150 7.894737 38 0.954624 3.76586 1.5 1 8.27 13611 700 47225 13.81579 47 1.670591 2.8033147 2 1 8.27 13611 800 77700 21.05263 54 2.545663 2.1721758 2.5 1 8.27 13611 900 95525 29.60526 53 3.579838 1.51088

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

1 6 1 8.27 13611 200 4300 15.78947 51 1.909247 2.7062332 6 1 13.7 17111 300 8925 23.68421 70 1.728774 2.3771113 6 1 20.6 21482 400 11900 31.57895 89 1.532959 2.1664 6 1 27.5 24820 500 39625 39.47368 98 1.435407 1.7865 6 1 34.4 27760 600 43150 47.36842 106 1.376989 1.5115566 6 1 48.2 32859 700 47225 55.26316 110 1.146539 1.1182867 6 1 55.1 35133 800 77700 63.15789 120 1.146241 1.0275838 6 1 68.9 39287 900 95525 71.05263 125 1.031243 0.7895569 6 1 75.8 41207 1000 116100 78.94737 130 1.041522 0.686533

10 6 1 89.6 44801 1125 128100 88.81579 130 0.991248 0.45487411 6 1 96.5 46494 1250 162650 98.68421 132 1.022634 0.35973312 6 1 110.3 49708 1375 179600 108.5526 139 0.984158 0.26438813 6 1 117.2 51239 1500 246050 118.4211 142 1.010419 0.20942214 6 1 124.1 52725 1750 422250 138.1579 180 1.113279 0.4046115 6 1 131 54171 2000 465500 157.8947 250 1.205303 0.753667

87

Page 99: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No.17 Summary of the confined concrete strength for unconfined concrete strength = 13.7MPa

Table No.18 Summary of the confined concrete strength for unconfined concrete strength = 20.6MPa No.

mm Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t cf cE ff fE lf ccf

c

lff

k

1 0.1 1 20.6 21482 200 4300 0.263158 5 0.012775 -59.282 0.25 1 20.6 21482 300 8925 0.986842 4 0.047905 -16.82133 0.5 1 20.6 21482 400 11900 2.631579 25 0.127747 1.6724 0.75 1 20.6 21482 500 39625 4.934211 27 0.239525 1.2970675 1 1 20.6 21482 600 43150 7.894737 35.5 0.38324 1.8873336 1.5 1 20.6 21482 700 47225 13.81579 37 0.670669 1.1870487 2 1 20.6 21482 800 77700 21.05263 46 1.021972 1.20658 2.5 1 20.6 21482 900 95525 29.60526 47 1.437149 0.8917339 3 1 20.6 21482 1000 116100 39.47368 50 1.916198 0.7448

10 3.5 1 20.6 21482 1125 128100 51.80921 55 2.51501 0.66397511 4 1 20.6 21482 1250 162650 65.78947 63 3.193664 0.6444812 4.5 1 20.6 21482 1375 179600 81.41447 67 3.952159 0.569923

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

1 0.1 1 13.7 17518 200 4300 0.263158 4 0.019209 -36.862 0.25 1 13.7 17518 300 8925 0.986842 15 0.072032 1.3173333 0.5 1 13.7 17518 400 11900 2.631579 17 0.192086 1.2544 0.75 1 13.7 17518 500 39625 4.934211 20 0.360161 1.27685 1 1 13.7 17518 600 43150 7.894737 25 0.576258 1.4313336 1.5 1 13.7 17518 700 47225 13.81579 30 1.008452 1.179817 2 1 13.7 17518 800 77700 21.05263 40 1.536688 1.249258 2.5 1 13.7 17518 900 95525 29.60526 43 2.160968 0.9896899 3 1 13.7 17518 1000 116100 39.47368 44 2.881291 0.7676

10 3.5 1 13.7 17518 1125 128100 51.80921 45 3.781694 0.60414

88

Page 100: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No.19 Summary of the confined concrete strength for unconfined concrete strength = 27.5MPa No.

mm Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

2 0.25 1 27.5 24820 300 8925 0.986842 8 0.035885 -19.763 0.5 1 27.5 24820 400 11900 2.631579 29 0.095694 0.574 0.75 1 27.5 24820 500 39625 4.934211 35 0.179426 1.525 1 1 27.5 24820 600 43150 7.894737 40 0.287081 1.5833336 1.5 1 27.5 24820 700 47225 13.81579 41 0.502392 0.9771437 2 1 27.5 24820 800 77700 21.05263 45 0.76555 0.831258 2.5 1 27.5 24820 900 95525 29.60526 51 1.076555 0.7937789 3 1 27.5 24820 1000 116100 39.47368 56 1.435407 0.722

10 3.5 1 27.5 24820 1125 128100 51.80921 60 1.883971 0.62730211 4 1 27.5 24820 1250 162650 65.78947 62 2.392344 0.524412 4.5 1 27.5 24820 1375 179600 81.41447 67 2.960526 0.48517213 5 1 27.5 24820 1500 246050 98.68421 73 3.588517 0.461067

Table No. 20 Summary of the confined concrete strength for unconfined concrete strength =34.4MPa

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

2 0.25 1 34.4 27760 300 8925 0.986842 15 0.028687 -19.65873 0.5 1 34.4 27760 400 11900 2.631579 40 0.076499 2.1284 0.75 1 34.4 27760 500 39625 4.934211 45 0.143436 2.1482675 1 1 34.4 27760 600 43150 7.894737 53 0.229498 2.3566 1.5 1 34.4 27760 700 47225 13.81579 60 0.401622 1.8529527 2 1 34.4 27760 800 77700 21.05263 65 0.611995 1.45358 2.5 1 34.4 27760 900 95525 29.60526 66.5 0.860618 1.0842679 3 1 34.4 27760 1000 116100 39.47368 71 1.147491 0.9272

10 3.5 1 34.4 27760 1125 128100 51.80921 73 1.506082 0.74504111 4 1 34.4 27760 1250 162650 65.78947 78 1.912485 0.6627212 4.5 1 34.4 27760 1375 179600 81.41447 88 2.3667 0.6583613 5 1 34.4 27760 1500 246050 98.68421 90 2.868727 0.56341314 5.5 1 34.4 27760 1750 422250 126.6447 110 3.681533 0.596945

89

Page 101: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No.21 Summary of the confined concrete strength for unconfined concrete strength = 48.2MPa No.

mm Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

2 0.25 1 48.2 32859 300 8925 0.986842 25 0.020474 -23.50933 0.5 1 48.2 32859 400 11900 2.631579 30 0.054597 -6.9164 0.75 1 48.2 32859 500 39625 4.934211 70 0.10237 4.4181335 1 1 48.2 32859 600 43150 7.894737 73.5 0.163791 3.2046676 1.5 1 48.2 32859 700 47225 13.81579 76 0.286635 2.012197 2 1 48.2 32859 800 77700 21.05263 85 0.436777 1.7488 2.5 1 48.2 32859 900 95525 29.60526 95 0.614217 1.58089 3 1 48.2 32859 1000 116100 39.47368 98 0.818956 1.2616

10 3.5 1 48.2 32859 1125 128100 51.80921 100 1.07488 0.99982211 4 1 48.2 32859 1250 162650 65.78947 80 1.364927 0.4833612 4.5 1 48.2 32859 1375 179600 81.41447 105 1.689097 0.69766513 5 1 48.2 32859 1500 246050 98.68421 120 2.04739 0.72757314 5.5 1 48.2 32859 1750 422250 126.6447 125 2.627484 0.60642115 6 1 48.2 32859 2000 465500 157.8947 129 3.275824 0.511733

Table No.22 Summary of the confined concrete strength for unconfined concrete strength = 55.1MPa

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

2 0.25 1 55.1 35133 300 8925 0.986842 25 0.01791 -30.50133 0.5 1 55.1 35133 400 11900 2.631579 35 0.04776 -7.6384 0.75 1 55.1 35133 500 39625 4.934211 56 0.08955 0.18245 1 1 55.1 35133 600 43150 7.894737 57 0.14328 0.2406676 1.5 1 55.1 35133 700 47225 13.81579 64 0.25074 0.644197 2 1 55.1 35133 800 77700 21.05263 70 0.38208 0.707758 2.5 1 55.1 35133 900 95525 29.60526 78 0.537301 0.7735119 3 1 55.1 35133 1000 116100 39.47368 85 0.716401 0.757467

10 3.5 1 55.1 35133 1125 128100 51.80921 90 0.940276 0.67362511 4 1 55.1 35133 1250 162650 65.78947 101 1.194001 0.6976812 4.5 1 55.1 35133 1375 179600 81.41447 109 1.477577 0.66204413 5 1 55.1 35133 1500 246050 98.68421 112 1.791002 0.57658714 5.5 1 55.1 35133 1750 422250 126.6447 123 2.298453 0.53614515 6 1 55.1 35133 2000 465500 157.8947 130 2.865603 0.474367

90

Page 102: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No.23 Summary of the confined concrete strength for unconfined concrete strength = 68.9MPa

Table No.24 Summary of the confined concrete strength for unconfined concrete strength = 75.8MPa No.

mm Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t cf cE ff fE lf ccf

c

lff

k

2 0.25 1 75.8 41207 300 8925 0.986842 35 0.013019 -41.3443 0.5 1 75.8 41207 400 11900 2.631579 40 0.034717 -13.6044 0.75 1 75.8 41207 500 39625 4.934211 60 0.065095 -3.202135 1 1 75.8 41207 600 43150 7.894737 77 0.104152 0.1526 1.5 1 75.8 41207 700 47225 13.81579 80 0.182266 0.3047 2 1 75.8 41207 800 77700 21.05263 90 0.277739 0.67458 2.5 1 75.8 41207 900 95525 29.60526 100 0.390571 0.8174229 3 1 75.8 41207 1000 116100 39.47368 105 0.520761 0.739733

10 3.5 1 75.8 41207 1125 128100 51.80921 110 0.683499 0.66011411 4 1 75.8 41207 1250 162650 65.78947 125 0.867935 0.7478412 4.5 1 75.8 41207 1375 179600 81.41447 135 1.07407 0.72714313 5 1 75.8 41207 1500 246050 98.68421 145 1.301903 0.70122714 5.5 1 75.8 41207 1750 422250 126.6447 140 1.670775 0.5069315 6 1 75.8 41207 2000 465500 157.8947 160 2.083044 0.533267

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

2 0.25 1 68.9 39287 300 8925 0.986842 20 0.014323 -49.5523 0.5 1 68.9 39287 400 11900 2.631579 40 0.038194 -10.9824 0.75 1 68.9 39287 500 39625 4.934211 70 0.071614 0.2229335 1 1 68.9 39287 600 43150 7.894737 87 0.114583 2.2926676 1.5 1 68.9 39287 700 47225 13.81579 95 0.200519 1.8891437 2 1 68.9 39287 800 77700 21.05263 105 0.305553 1.714758 2.5 1 68.9 39287 900 95525 29.60526 100 0.429685 1.0504899 3 1 68.9 39287 1000 116100 39.47368 110 0.572913 1.0412

10 3.5 1 68.9 39287 1125 128100 51.80921 125 0.751948 1.08281911 4 1 68.9 39287 1250 162650 65.78947 130 0.954854 0.9287212 4.5 1 68.9 39287 1375 179600 81.41447 145 1.181632 0.93472313 5 1 68.9 39287 1500 246050 98.68421 150 1.432282 0.82181314 5.5 1 68.9 39287 1750 422250 126.6447 160 1.838095 0.71933515 6 1 68.9 39287 2000 465500 157.8947 220 2.291651 0.956967

91

Page 103: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No.25 Summary of the confined concrete strength for unconfined concrete strength = 89.6MPa

Table No. 26 Summary of the confined concrete strength for unconfined concrete strength = 96.5MPa

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

2 0.25 1 89.6 44801 300 8925 0.986842 30 0.011014 -60.39473 0.5 1 89.6 44801 400 11900 2.631579 35 0.02937 -20.7484 0.75 1 89.6 44801 500 39625 4.934211 40 0.055069 -10.05235 1 1 89.6 44801 600 43150 7.894737 92 0.088111 0.3046 1.5 1 89.6 44801 700 47225 13.81579 95 0.154194 0.3908577 2 1 89.6 44801 800 77700 21.05263 100 0.234962 0.4948 2.5 1 89.6 44801 900 95525 29.60526 110 0.330416 0.6890679 3 1 89.6 44801 1000 116100 39.47368 115 0.440555 0.643467

10 3.5 1 89.6 44801 1125 128100 51.80921 121 0.578228 0.6060711 4 1 89.6 44801 1250 162650 65.78947 129 0.734258 0.5988812 4.5 1 89.6 44801 1375 179600 81.41447 135 0.908644 0.5576413 5 1 89.6 44801 1500 246050 98.68421 140 1.101386 0.5107214 5.5 1 89.6 44801 1750 422250 126.6447 150 1.413446 0.47692515 6 1 89.6 44801 2000 465500 157.8947 180 1.762218 0.572533

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

2 0.25 1 96.5 46494 300 8925 0.986842 34 0.010226 -63.33333 0.5 1 96.5 46494 400 11900 2.631579 40 0.02727 -21.474 0.75 1 96.5 46494 500 39625 4.934211 42 0.051132 -11.04535 1 1 96.5 46494 600 43150 7.894737 100 0.081811 0.4433336 1.5 1 96.5 46494 700 47225 13.81579 103 0.143169 0.4704767 2 1 96.5 46494 800 77700 21.05263 110 0.218162 0.641258 2.5 1 96.5 46494 900 95525 29.60526 125 0.30679 0.9626679 3 1 96.5 46494 1000 116100 39.47368 128 0.409054 0.798

10 3.5 1 96.5 46494 1125 128100 51.80921 135 0.536883 0.74311111 4 1 96.5 46494 1250 162650 65.78947 145 0.681756 0.737212 4.5 1 96.5 46494 1375 179600 81.41447 150 0.843673 0.65713113 5 1 96.5 46494 1500 246050 98.68421 165 1.022634 0.69413314 5.5 1 96.5 46494 1750 422250 126.6447 185 1.312381 0.69880515 6 1 96.5 46494 2000 465500 157.8947 210 1.636215 0.718833

92

Page 104: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No.27 Summary of the confined concrete strength for unconfined concrete strength = 110.3MPa

Table No.28 Summary of the confined concrete strength for unconfined concrete strength = 117.2MPa No.

mm Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t cf cE ff fE lf ccf

c

lff

k

3 0.5 1 117.2 51239 400 11900 2.631579 40 0.022454 -29.3364 0.75 1 117.2 51239 500 39625 4.934211 43 0.042101 -15.03795 1 1 117.2 51239 600 43150 7.894737 95 0.067361 -2.8126 1.5 1 117.2 51239 700 47225 13.81579 119 0.117882 0.1302867 2 1 117.2 51239 800 77700 21.05263 125 0.17963 0.37058 2.5 1 117.2 51239 900 95525 29.60526 130 0.252605 0.4323569 3 1 117.2 51239 1000 116100 39.47368 145 0.336806 0.704267

10 3.5 1 117.2 51239 1125 128100 51.80921 150 0.442058 0.63309211 4 1 117.2 51239 1250 162650 65.78947 165 0.561344 0.7265612 4.5 1 117.2 51239 1375 179600 81.41447 210 0.694663 1.13984613 5 1 117.2 51239 1500 246050 98.68421 225 0.842015 1.09237314 5.5 1 117.2 51239 1750 422250 126.6447 270 1.080586 1.20652515 6 1 117.2 51239 2000 465500 157.8947 295 1.347225 1.126067

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

3 0.5 1 110.3 49708 400 11900 2.631579 35 0.023858 -28.6144 0.75 1 110.3 49708 500 39625 4.934211 40 0.044734 -14.24755 1 1 110.3 49708 600 43150 7.894737 115 0.071575 0.5953336 1.5 1 110.3 49708 700 47225 13.81579 117 0.125256 0.4849527 2 1 110.3 49708 800 77700 21.05263 120 0.190867 0.460758 2.5 1 110.3 49708 900 95525 29.60526 131 0.268407 0.69929 3 1 110.3 49708 1000 116100 39.47368 139 0.357876 0.727067

10 3.5 1 110.3 49708 1125 128100 51.80921 144 0.469712 0.65046311 4 1 110.3 49708 1250 162650 65.78947 150 0.596459 0.6034412 4.5 1 110.3 49708 1375 179600 81.41447 160 0.738119 0.61045713 5 1 110.3 49708 1500 246050 98.68421 165 0.894689 0.55429314 5.5 1 110.3 49708 1750 422250 126.6447 240 1.148184 1.02412515 6 1 110.3 49708 2000 465500 157.8947 250 1.431503 0.884767

93

Page 105: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No. 29 Summary of the confined concrete strength for unconfined concrete strength = 124.1 MPa

Table No.30 Summary of the confined concrete strength for unconfined concrete strength = 131MPa No.

mm Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t cf cE ff fE lf ccf

c

lff

k

3 0.5 1 131 54171 400 11900 2.631579 50 0.020088 -30.784 0.75 1 131 54171 500 39625 4.934211 55 0.037666 -15.40275 1 1 131 54171 600 43150 7.894737 57 0.060265 -9.373336 1.5 1 131 54171 700 47225 13.81579 132 0.105464 0.0723817 2 1 131 54171 800 77700 21.05263 135 0.160707 0.198 2.5 1 131 54171 900 95525 29.60526 138 0.225994 0.2364449 3 1 131 54171 1000 116100 39.47368 145 0.301326 0.354667

10 3.5 1 131 54171 1125 128100 51.80921 150 0.39549 0.3667311 4 1 131 54171 1250 162650 65.78947 154 0.50221 0.349612 4.5 1 131 54171 1375 179600 81.41447 175 0.621485 0.54044413 5 1 131 54171 1500 246050 98.68421 195 0.753315 0.64853314 5.5 1 131 54171 1750 422250 126.6447 240 0.966754 0.86067515 6 1 131 54171 2000 465500 157.8947 300 1.205303 1.070333

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

3 0.5 1 124.1 52725 400 11900 2.631579 40 0.021205 -31.9584 0.75 1 124.1 52725 500 39625 4.934211 45 0.03976 -16.03095 1 1 124.1 52725 600 43150 7.894737 47 0.063616 -9.7666 1.5 1 124.1 52725 700 47225 13.81579 126 0.111328 0.1375247 2 1 124.1 52725 800 77700 21.05263 130 0.169642 0.280258 2.5 1 124.1 52725 900 95525 29.60526 136 0.23856 0.4019569 3 1 124.1 52725 1000 116100 39.47368 140 0.31808 0.4028

10 3.5 1 124.1 52725 1125 128100 51.80921 142 0.41748 0.34549811 4 1 124.1 52725 1250 162650 65.78947 147 0.530133 0.3480812 4.5 1 124.1 52725 1375 179600 81.41447 152 0.656039 0.34269113 5 1 124.1 52725 1500 246050 98.68421 165 0.795199 0.41445314 5.5 1 124.1 52725 1750 422250 126.6447 220 1.020506 0.75723615 6 1 124.1 52725 2000 465500 157.8947 240 1.272319 0.734033

94

Page 106: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No.31 Summary of the confined concrete strength for longitudinal tensile strength = 200MPa

Table No.32 Summary of the confined concrete strength for longitudinal tensile strength = 300MPa

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

1 0.1 1 8.27 13611 200 4300 0.263158 3 0.031821 -20.0262 0.25 1 13.7 17111 200 8925 0.657895 12 0.048022 -2.5843 0.5 1 20.6 21482 200 11900 1.315789 19 0.063873 -1.2164 0.75 1 27.5 24820 200 39625 1.973684 29 0.07177 0.765 1 1 34.4 27760 200 43150 2.631579 36 0.076499 0.6086 1.5 1 48.2 32859 200 47225 3.947368 52 0.081896 0.9626677 2 1 55.1 35133 200 77700 5.263158 62 0.09552 1.3118 2.5 1 68.9 39287 200 95525 6.578947 70 0.095485 0.16729 3 1 75.8 41207 200 116100 7.894737 100 0.104152 3.065333

10 3.5 1 89.6 44801 200 128100 9.210526 110 0.102796 2.21485711 4 1 96.5 46494 200 162650 10.52632 117 0.109081 1.947512 4.5 1 110.3 49708 200 179600 11.84211 140 0.107363 2.50813 5 1 117.2 51239 200 246050 13.15789 140 0.112269 1.732814 5.5 1 124.1 52725 200 422250 14.47368 155 0.116629 2.13490915 6 1 131 54171 200 465500 15.78947 143 0.12053 0.76

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

1 0.1 1 8.27 13611 300 4300 0.394737 3 0.047731 -13.35072 0.25 1 13.7 17111 300 8925 0.986842 15 0.072032 1.3173333 0.5 1 20.6 21482 300 11900 1.973684 31 0.09581 5.2693334 0.75 1 27.5 24820 300 39625 2.960526 40.2 0.107656 4.2897785 1 1 34.4 27760 300 43150 3.947368 59 0.114749 6.2326 1.5 1 48.2 32859 300 47225 5.921053 78 0.122843 5.0328897 2 1 55.1 35133 300 77700 7.894737 60 0.14328 0.6206678 2.5 1 68.9 39287 300 95525 9.868421 80 0.143228 1.12489 3 1 75.8 41207 300 116100 11.84211 87 0.156228 0.945778

10 3.5 1 89.6 44801 300 128100 13.81579 100 0.154194 0.75276211 4 1 96.5 46494 300 162650 15.78947 109 0.163621 0.79166712 4.5 1 110.3 49708 300 179600 17.76316 117 0.161044 0.37718513 5 1 117.2 51239 300 246050 19.73684 122 0.168403 0.243214 5.5 1 124.1 52725 300 422250 21.71053 230 0.174944 4.87781815 6 1 131 54171 300 465500 23.68421 280 0.180796 6.291111

95

Page 107: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No.33 Summary of the confined concrete strength for longitudinal tensile strength = 400MPa

Table No. 34 Summary of the confined concrete strength for longitudinal tensile strength = 500MPa No.

mm Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t cf cE ff fE lf ccf

c

lff

k

1 0.1 1 8.27 13611 500 4300 0.657895 14 0.079552 8.70962 0.25 1 13.7 17111 500 8925 1.644737 21 0.120054 4.43843 0.5 1 20.6 21482 500 11900 3.289474 30 0.159683 2.85764 0.75 1 27.5 24820 500 39625 4.934211 39 0.179426 2.3306675 1 1 34.4 27760 500 43150 6.578947 49 0.191248 2.21926 1.5 1 48.2 32859 500 47225 9.868421 61 0.204739 1.2970677 2 1 55.1 35133 500 77700 13.15789 73 0.2388 1.36048 2.5 1 68.9 39287 500 95525 16.44737 80 0.238714 0.674889 3 1 75.8 41207 500 116100 19.73684 84 0.260381 0.415467

10 3.5 1 89.6 44801 500 128100 23.02632 125 0.25699 1.53737111 4 1 96.5 46494 500 162650 26.31579 115 0.272702 0.70312 4.5 1 110.3 49708 500 179600 29.60526 139 0.268407 0.96942213 5 1 117.2 51239 500 246050 32.89474 136 0.280672 0.5715214 5.5 1 124.1 52725 500 422250 36.18421 280 0.291573 4.30850915 6 1 131 54171 500 465500 39.47368 310 0.301326 4.534667

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

1 0.1 1 8.27 13611 400 4300 0.526316 8 0.063642 -0.5132 0.25 1 13.7 17111 400 8925 1.315789 16 0.096043 1.7483 0.5 1 20.6 21482 400 11900 2.631579 28 0.127747 2.8124 0.75 1 27.5 24820 400 39625 3.947368 28 0.143541 0.1266675 1 1 34.4 27760 400 43150 5.263158 37 0.152999 0.4946 1.5 1 48.2 32859 400 47225 7.894737 51 0.163791 0.3546677 2 1 55.1 35133 400 77700 10.52632 57 0.19104 0.18058 2.5 1 68.9 39287 400 95525 13.15789 70 0.190971 0.08369 3 1 75.8 41207 400 116100 15.78947 79 0.208304 0.202667

10 3.5 1 89.6 44801 400 128100 18.42105 95 0.205592 0.29314311 4 1 96.5 46494 400 162650 21.05263 105 0.218162 0.4037512 4.5 1 110.3 49708 400 179600 23.68421 110 0.214725 -0.0126713 5 1 117.2 51239 400 246050 26.31579 126 0.224537 0.334414 5.5 1 124.1 52725 400 422250 28.94737 280 0.233258 5.38563615 6 1 131 54171 400 465500 31.57895 310 0.241061 5.668333

96

Page 108: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No. 35 Summary of the confined concrete strength for longitudinal tensile strength = 600MPa

Table No.36 Summary of the confined concrete strength for longitudinal tensile strength = 700MPa No.

mm Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t cf cE ff fE lf ccf

c

lff

k

1 0.1 1 8.27 13611 700 4300 0.921053 19 0.111373 11.649712 0.25 1 13.7 17111 700 8925 2.302632 30 0.168075 7.0788573 0.5 1 20.6 21482 700 11900 4.605263 39 0.223556 3.9954294 0.75 1 27.5 24820 700 39625 6.907895 48 0.251196 2.9676195 1 1 34.4 27760 700 43150 9.210526 51 0.267748 1.8022866 1.5 1 48.2 32859 700 47225 13.81579 63 0.286635 1.0712387 2 1 55.1 35133 700 77700 18.42105 79 0.33432 1.2974298 2.5 1 68.9 39287 700 95525 23.02632 80 0.334199 0.4820579 3 1 75.8 41207 700 116100 27.63158 86 0.364533 0.369143

10 3.5 1 89.6 44801 700 128100 32.23684 105 0.359786 0.47771411 4 1 96.5 46494 700 162650 36.84211 135 0.381783 1.04512 4.5 1 110.3 49708 700 179600 41.44737 152 0.375769 1.00609513 5 1 117.2 51239 700 246050 46.05263 166 0.392941 1.05965714 5.5 1 124.1 52725 700 422250 50.65789 280 0.408202 3.07750615 6 1 131 54171 700 465500 55.26316 310 0.421856 3.239048

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

1 0.1 1 8.27 13611 600 4300 0.789474 16 0.095462 9.79133 2 0.25 1 13.7 17111 600 8925 1.973684 27 0.144065 6.7386673 0.5 1 20.6 21482 600 11900 3.947368 36 0.19162 3.90133 4 0.75 1 27.5 24820 600 39625 5.921053 50 0.215311 3.8 5 1 1 34.4 27760 600 43150 7.894737 53 0.229498 2.356 6 1.5 1 48.2 32859 600 47225 11.84211 65 0.245687 1.4186677 2 1 55.1 35133 600 77700 15.78947 69 0.28656 0.88033 8 2.5 1 68.9 39287 600 95525 19.73684 73 0.286456 0.2077339 3 1 75.8 41207 600 116100 23.68421 85 0.312457 0.38844410 3.5 1 89.6 44801 600 128100 27.63158 125 0.308388 1.28114311 4 1 96.5 46494 600 162650 31.57895 140 0.327243 1.3775 12 4.5 1 110.3 49708 600 179600 35.52632 169 0.322088 1.65229613 5 1 117.2 51239 600 246050 39.47368 156 0.336806 0.98293314 5.5 1 124.1 52725 600 422250 43.42105 280 0.349888 3.59 15 6 1 131 54171 600 465500 47.36842 310 0.361591 3.77

97

Page 109: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No. 37 Summary of the confined concrete strength for longitudinal tensile strength = 800MPa

Table No. 38 Summary of the confined concrete strength for longitudinal tensile strength = 900MPa

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

1 0.1 1 8.27 13611 800 4300 1.052632 22 0.127283 13.04352 0.25 1 13.7 17111 800 8925 2.631579 35 0.192086 8.0943 0.5 1 20.6 21482 800 11900 5.263158 42 0.255493 4.0664 0.75 1 27.5 24820 800 39625 7.894737 55 0.287081 3.4833335 1 1 34.4 27760 800 43150 10.52632 75 0.305998 3.8576 1.5 1 48.2 32859 800 47225 15.78947 81 0.327582 2.0773337 2 1 55.1 35133 800 77700 21.05263 120 0.38208 3.082758 2.5 1 68.9 39287 800 95525 26.31579 149 0.381942 3.04389 3 1 75.8 41207 800 116100 31.57895 100 0.416609 0.766333

10 3.5 1 89.6 44801 800 128100 36.84211 155 0.411184 1.77514311 4 1 96.5 46494 800 162650 42.10526 160 0.436324 1.50812512 4.5 1 110.3 49708 800 179600 47.36842 172 0.429451 1.30255613 5 1 117.2 51239 800 246050 52.63158 185 0.449075 1.288214 5.5 1 124.1 52725 800 422250 57.89474 230 0.466517 1.82918215 6 1 131 54171 800 465500 63.15789 280 0.482121 2.359167

No. mm

Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

1 0.1 1 8.27 13611 900 4300 1.184211 9.8 0.143194 1.2922 0.25 1 13.7 17111 900 8925 2.960526 27 0.216097 4.4924443 0.5 1 20.6 21482 900 11900 5.921053 42 0.28743 3.6142224 0.75 1 27.5 24820 900 39625 8.881579 62 0.322967 3.8844445 1 1 34.4 27760 900 43150 11.84211 72 0.344247 3.1751116 1.5 1 48.2 32859 900 47225 17.76316 87 0.36853 2.1842967 2 1 55.1 35133 900 77700 23.68421 99 0.42984 1.8535568 2.5 1 68.9 39287 900 95525 29.60526 110 0.429685 1.3882679 3 1 75.8 41207 900 116100 35.52632 128 0.468685 1.469333

10 3.5 1 89.6 44801 900 128100 41.44737 135 0.462582 1.09536511 4 1 96.5 46494 900 162650 47.36842 145 0.490864 1.02388912 4.5 1 110.3 49708 900 179600 53.28947 159 0.483132 0.91387713 5 1 117.2 51239 900 246050 59.21053 166 0.505209 0.82417814 5.5 1 124.1 52725 900 422250 65.13158 230 0.524831 1.62593915 6 1 131 54171 900 465500 71.05263 260 0.542387 1.815556

98

Page 110: Modeling of Fiber Reinforced Polymer confined concrete ...

Table No. 39 Summary of the confined concrete strength for longitudinal tensile strength = 1000MPa No.

mm Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

1 0.1 1 8.27 13611 1000 4300 1.315789 10 0.159104 1.31482 0.25 1 13.7 17111 1000 8925 3.289474 17 0.240108 1.00323 0.5 1 20.6 21482 1000 11900 6.578947 35 0.319366 2.18884 0.75 1 27.5 24820 1000 39625 9.868421 36 0.358852 0.8613335 1 1 34.4 27760 1000 43150 13.15789 40 0.382497 0.42566 1.5 1 48.2 32859 1000 47225 19.73684 65 0.409478 0.85127 2 1 55.1 35133 1000 77700 26.31579 85 0.477601 1.13628 2.5 1 68.9 39287 1000 95525 32.89474 87 0.477427 0.550249 3 1 75.8 41207 1000 116100 39.47368 100 0.520761 0.61306710 3.5 1 89.6 44801 1000 128100 46.05263 111 0.51398 0.46468611 4 1 96.5 46494 1000 162650 52.63158 105 0.545405 0.161512 4.5 1 110.3 49708 1000 179600 59.21053 132 0.536813 0.36648913 5 1 117.2 51239 1000 246050 65.78947 136 0.561344 0.2857614 5.5 1 124.1 52725 1000 422250 72.36842 230 0.583146 1.46334515 6 1 131 54171 1000 465500 78.94737 280 0.602652 1.887333 Table No. 40 Summary of the confined concrete strength for longitudinal tensile strength = 2000MPa No.

mm Number of layers

MPa

MPa

MPa

MPa

MPa

MPa

t k ff fE

c

lff

cf cE lf ccf

1 0.1 1 8.27 13611 2000 4300 2.631579 10 0.318208 0.65742 0.25 1 13.7 17111 2000 8925 6.578947 21 0.480215 1.10963 0.5 1 20.6 21482 2000 11900 13.15789 35 0.638733 1.09444 0.75 1 27.5 24820 2000 39625 19.73684 40 0.717703 0.6333335 1 1 34.4 27760 2000 43150 26.31579 93 0.764994 2.22686 1.5 1 48.2 32859 2000 47225 39.47368 149 0.818956 2.55367 2 1 55.1 35133 2000 77700 52.63158 160 0.955201 1.99318 2.5 1 68.9 39287 2000 95525 65.78947 110 0.954854 0.624729 3 1 75.8 41207 2000 116100 78.94737 170 1.041522 1.193210 3.5 1 89.6 44801 2000 128100 92.10526 195 1.027961 1.14434311 4 1 96.5 46494 2000 162650 105.2632 197 1.09081 0.9547512 4.5 1 110.3 49708 2000 179600 118.4211 229 1.073627 1.00235613 5 1 117.2 51239 2000 246050 131.5789 234 1.122687 0.8876814 5.5 1 124.1 52725 2000 422250 144.7368 243 1.166292 0.82149115 6 1 131 54171 2000 465500 157.8947 250 1.205303 0.753667

99

Page 111: Modeling of Fiber Reinforced Polymer confined concrete ...

APPENDIX C: PSEUDO INVERSE METHOD

In the Pseudo-Inverse Method, a matrix is defined as

(1)

Where and

nm× +A

TUVA ++ Σ=

[ ]muuU ,....,1= [ ]nvvV ,....,1= ⎟⎟⎠

⎞⎜⎜⎝

⎛=Σ+ 0,...,0,1,...,1

1 r

diagσσ

)(Arankr =

The, is referred to as the pseudo inverse of+A A . The pseudo inverse method is the approximate

least squares solution for a system of linear equations. The pseudo inverse is generally computed

by singular value decomposition. If the nArank =)( , then ( ) TT AAAA 1−+ = , while if

then , is defined to be a unique )(Aranknm == −+ = AA . +A nm× matrix X which satisfies

the four Moore-Penrose conditions

(2)

(3)

(4)

(5)

In these conditions, and are the orthogonal projections on to the ranges of

AAXA =

XXAX =

( ) XAXA T =

( ) XAXA T =

+AA AA+ A and

respectively. For the above problem, if +A ( ) 1−AAT exists then

(6)

(7)

(8)

(9)

Therefore, (10)

cyA =

cAyAA TT =

( ) ( ) ( ) cAAAyAAAA TTTT 11 −−=

( ) ( )yAAAc TT 1−=

yAc +=

100

Page 112: Modeling of Fiber Reinforced Polymer confined concrete ...

101

VITA

Indrani V Volety was born in Hyderabad, India. She earned a bachelor of engineering degree in

mechanical engineering from Chaitanya Bharathi Institute of Technology, India, in June 2003.

She enrolled in the master’s program in mechanical engineering at Louisiana State University,

Baton Rouge, Louisiana, in fall 2003. She will receive the degree of Master of Science in

mechanical engineering in May 2006.