Modeling and Simulationof
The Induction motorfeed by
Matrix converter
![Page 2: Modeling and simulation of the induction motor feed by matrix converter](https://reader036.fdocuments.in/reader036/viewer/2022062513/555c5617d8b42af3448b4cd0/html5/thumbnails/2.jpg)
ac to ac converter
1. Direct converter(No use dc link)
2. Indirect converter(Utilize dc link Between two ac systems)
Matrix converters are Direct converter.
![Page 3: Modeling and simulation of the induction motor feed by matrix converter](https://reader036.fdocuments.in/reader036/viewer/2022062513/555c5617d8b42af3448b4cd0/html5/thumbnails/3.jpg)
Matrix Converter
3 Phase matrix converter consists 9 bi-directional switches.
Suppression of power harmonics.
It provides input and output sinusoidal waveforms.
It is capable of regenerating energy back to the main supply.
There is no reactive component for storage purpose.
Four quadrant operation.
Longer operating life.
![Page 4: Modeling and simulation of the induction motor feed by matrix converter](https://reader036.fdocuments.in/reader036/viewer/2022062513/555c5617d8b42af3448b4cd0/html5/thumbnails/4.jpg)
Modulation Techniques of Matrix Converter
Alesina –Venturini modulation technique
or
Optimum Venturini amplitude Modulation (OVAM)
Scalar modulation technique.
Space vector modulation technique.
(Used for producing the gating signals)
indirect modulation technique.
Use for change the voltage Transfer ratio.
![Page 5: Modeling and simulation of the induction motor feed by matrix converter](https://reader036.fdocuments.in/reader036/viewer/2022062513/555c5617d8b42af3448b4cd0/html5/thumbnails/5.jpg)
Optimum Venturini amplitude Modulation (OVAM) Technique
This method provides the amplitude of output voltage up
to 86.6% of input voltage.
Also provides unity fundamental displacement factor at the
input regardless of the load displacement factor.
![Page 6: Modeling and simulation of the induction motor feed by matrix converter](https://reader036.fdocuments.in/reader036/viewer/2022062513/555c5617d8b42af3448b4cd0/html5/thumbnails/6.jpg)
Induction Motor
The squirrel cage type of induction motor is very popular in case of
variable-speed drives.
Available in all power ratings.
Also used for Constant speed applications.
Needs no extra starting motor and need not be synchronized.
Low cost and minimum maintenance.
High reliability and sufficiently high efficiency.
![Page 7: Modeling and simulation of the induction motor feed by matrix converter](https://reader036.fdocuments.in/reader036/viewer/2022062513/555c5617d8b42af3448b4cd0/html5/thumbnails/7.jpg)
Modeling and Simulation
![Page 8: Modeling and simulation of the induction motor feed by matrix converter](https://reader036.fdocuments.in/reader036/viewer/2022062513/555c5617d8b42af3448b4cd0/html5/thumbnails/8.jpg)
Modeling of matrix converter
![Page 9: Modeling and simulation of the induction motor feed by matrix converter](https://reader036.fdocuments.in/reader036/viewer/2022062513/555c5617d8b42af3448b4cd0/html5/thumbnails/9.jpg)
Modeling of Subsystem block
![Page 10: Modeling and simulation of the induction motor feed by matrix converter](https://reader036.fdocuments.in/reader036/viewer/2022062513/555c5617d8b42af3448b4cd0/html5/thumbnails/10.jpg)
Resultant Waveforms
Input Current of matric converter
Output Current of matric converter
![Page 11: Modeling and simulation of the induction motor feed by matrix converter](https://reader036.fdocuments.in/reader036/viewer/2022062513/555c5617d8b42af3448b4cd0/html5/thumbnails/11.jpg)
Input Voltage of matric converter
Output Voltage of matric converter
![Page 12: Modeling and simulation of the induction motor feed by matrix converter](https://reader036.fdocuments.in/reader036/viewer/2022062513/555c5617d8b42af3448b4cd0/html5/thumbnails/12.jpg)
Rotor speed of induction motor
Stator Current of induction motor
![Page 13: Modeling and simulation of the induction motor feed by matrix converter](https://reader036.fdocuments.in/reader036/viewer/2022062513/555c5617d8b42af3448b4cd0/html5/thumbnails/13.jpg)
Electromagnetic torque of Induction motor
![Page 14: Modeling and simulation of the induction motor feed by matrix converter](https://reader036.fdocuments.in/reader036/viewer/2022062513/555c5617d8b42af3448b4cd0/html5/thumbnails/14.jpg)
Conclusions
Odd/low order harmonics do not contribute the output power of the
motor, they produce additional losses in the machine. These are
suppressed by Matrix converter.
Harmonic losses reduces the efficiency and cause derating of the motor
and increases torque pulsating.
Regeneration ability and four quadrant Operation meets the stringent
energy efficiency and power quality.
Increase input Power factor.