Mobile Installation
-
Upload
dachronicmaster -
Category
Documents
-
view
16 -
download
3
description
Transcript of Mobile Installation
IF Cable connector
H Type connector-ODUypH-LP-8DFB(S)
L Type connector-IDUN-LP-8DFBN-LP-TNC
IF Cable connector
H Type connector-ODU
√H-LP-8DFB(S) √L Type connector-IDUN-LP-8DFBN LP TNCN-LP-TNC
H Type connetor constitution
January 13, 2007 NEC Corporation 2007 3
ODU H Type connector installation
January 13, 2007 NEC Corporation 2007 4
IF Cable connector
H Type connector-ODUH-LP-8DFB(S)
L Type connector-IDU
√N-LP-8DFB√N LP TNCN-LP-TNC
N-LP-8DFB IDU Instruction
January 13, 2007 NEC Corporation 2007 6
L-Type connector-1
1 Take off the Tightenig nut fitting and take each part from the mainbody
January 13, 2007 NEC Corporation 2007 7
1. Take off the Tightenig nut fitting and take each part from the mainbody.
L-Type connector-2
2. Two gasket attached. Use only 1 gasket and store the other one.
January 13, 2007 NEC Corporation 2007 8
g y g
L-Type connector-3yp
Clamp
Hood
3.Insert the clamp to the stripped cable jacket end. Open the end of the outer conductor a little.4. Insert the hood between the plastic tape with aluminum foil and the outer conductor.5. No gap is allowed in between the clamp, the outer conductor and the hood.
January 13, 2007 NEC Corporation 2007 9
L-Type connector-4
6. After inserting the hood, cut off the plastic tape with aluminum foil and the dielectric at A-surfacedielectric at A surface.7. Cut off the part of the outer conductor exceeding the clamp rim with a scissor.8. Check that distance between the tip of the center conductor and A-Surface is 6 7mm Chamfer at the tip of the inner conductor
January 13, 2007 NEC Corporation 2007 10
6-7mm. Chamfer at the tip of the inner conductor.
L-Type connector-5
9. Insert the insulation washer to the center conductor, and engage it the F/f Contact.10 N i ll d i b t th F/F C t t th i l ti h10. No gap is allowed in between the F/F Contact, the insulation washer, and the dielectric.11. Combine the convex part of the clamp to the concave part of the gasket.
January 13, 2007 NEC Corporation 2007 11
L-Type connector-6
1-2mm
12. Tighten the tightening nut sufficiently until the gasket is cut by the 13. Torque fot the tightening nut shall be 8-30N-m.14. Distance between the tightening nut is 1-2mm.
January 13, 2007 NEC Corporation 2007 12
g g
IF Cable connector
L Type connector-IDU
N-LP-8DFB
√N-LP-TNC√√
TNC connector making instruction-1
January 13, 2007 NEC Corporation 2007 14
TNC connector making instruction-2
January 13, 2007 NEC Corporation 2007 15
TNC connector making instruction-3
January 13, 2007 NEC Corporation 2007 16
TNC connector making instruction-4
January 13, 2007 NEC Corporation 2007 17
TNC connector making picture-1
January 13, 2007 NEC Corporation 2007 18
TNC connector making picture-2
January 13, 2007 NEC Corporation 2007 19
TNC connector making picture-3
January 13, 2007 NEC Corporation 2007 20
TNC connector making picture-4
January 13, 2007 NEC Corporation 2007 21