Mid Term Revision
Imaging Procedure 1
Dr Mohamed El Safwany, MD.
![Page 2: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/2.jpg)
Creating the ImageCreating the Image
• ScatterScatter–Creates fogCreates fog
–Lowers contrast (more grays)Lowers contrast (more grays)
• Increases as Increases as
–kV increaseskV increases
–Field size increasesField size increases
–Thickness of part increasesThickness of part increases
![Page 3: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/3.jpg)
Effects of collimation on scatterEffects of collimation on scatter
![Page 4: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/4.jpg)
• Collimate to area Collimate to area of interest -of interest -reduces scatter reduces scatter and radiation and radiation dose to the dose to the patientpatient
![Page 5: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/5.jpg)
GridsGrids
• A device with lead strips that is placed A device with lead strips that is placed between the patient and the cassettebetween the patient and the cassette
• Used on larger body parts to reduce the Used on larger body parts to reduce the number of scattering photons from number of scattering photons from reaching the imagereaching the image
![Page 6: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/6.jpg)
Grid is placedGrid is placedbetween patient (behind table or upright between patient (behind table or upright
bucky) & cassettebucky) & cassetteIf placed BACWARDS CAN CAUSE If placed BACWARDS CAN CAUSE
GRID ERRORSGRID ERRORS
![Page 7: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/7.jpg)
Factors that affect the detail of Factors that affect the detail of an imagean image
![Page 8: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/8.jpg)
SID SID Source to Image DistanceSource to Image Distance
• The greater the distance between the The greater the distance between the source of the x-ray (tube) and the image source of the x-ray (tube) and the image receptor (cassette), the greater the image receptor (cassette), the greater the image sharpness.sharpness.
• Standard distance = 40 in. most examsStandard distance = 40 in. most exams
• Exception = Chest radiography 72 in.Exception = Chest radiography 72 in.
*See page 74 in your book*See page 74 in your book
![Page 9: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/9.jpg)
Shape DistortionShape Distortion
• Misrepresentation of the shape of an Misrepresentation of the shape of an objectobject
• Controlled by alignment of the beam, part Controlled by alignment of the beam, part (object), & image receptor(object), & image receptor
• Influences: Central ray angulation & body Influences: Central ray angulation & body part rotationpart rotation
![Page 10: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/10.jpg)
Bone Classification
• Long
• Flat
• Short
• Irregular
![Page 11: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/11.jpg)
Centers of Endochondral Ossification
• Primary center- midbody or diaphysis
• Secondary center- ends or extremities of the long bones or epiphysis– Epiphyseal plates: found between the
diaphysis and the epiphysis until skeletal growth is complete
![Page 12: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/12.jpg)
Anatomic Position
• Upright, arms adducted, palms forward, head and feet directed straight ahead
• Viewing Radiographs: Display x-rays so that the
patient is facing the viewer in anatomic position
R
![Page 13: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/13.jpg)
Body Planes, Sections and Lines
• Sagittal- any longitudinal plane dividing the body into right and left parts
• Mid-sagittal or median plane- divides the body into equal right and left halves
• Coronal- longitudinal plane dividing the body into anterior and posterior parts
• Mid-coronal- divides the body into equal anterior and posterior parts
![Page 14: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/14.jpg)
• Horizontal or axial plane- transverse plane passing through the body at right angles to the longitudinal plane; divides into superior and inferior portions
• Oblique plane- longitudinal or transverse that is on an angle or slant to the sagittal, coronal or horizontal planes.
![Page 15: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/15.jpg)
Understanding CT and MRI Images
• Longitudinal sections can be taken in sagittal, coronal or oblique planes
• Transverse (axial) or cross sections
![Page 16: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/16.jpg)
Gastrointestional Fluoroscopy
• Esophogram/Barium Swallow
• Modified Barium Swallow/Dysphgiagram
• Upper GI
• Small Bowel Series
• Enteroclysis
• Contrast Enema
• Defecography
![Page 17: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/17.jpg)
Single Contrast vs Double Contrast
• Single Contrast– Generally uses just thin Barium– Distends lumen with high density material– Easier for patient/less mucosal detail
• Double Contrast/Air Contrast– Thick barium coats lumen– Effervescent tablets ingested to distend lumen with air– Produces ‘see-through’ images with greater mucosal
detail – Greater sensitivity for small lesions, polyps, ulcers
![Page 18: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/18.jpg)
Contrast Enemas
• Barium or Gastrograffin
• Double contrast or single contrast
• Generally less sensitive than endoscopy
• Requires bowel prep to assess for mucosal lesions
• Requires some element of patient cooperation
![Page 19: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/19.jpg)
Hysterosalpingogram
• Used to evaluate endometrial canal and fallopian tubes
• Infertility and uterine anomalies
• Dye injected into cervical os under fluoro
• Injection continued with goal to opacify the fallopian tubes and spill contrast into peritoneum
![Page 20: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/20.jpg)
Magnetic Resonance Imaging (MRI)
• Multi-planar scanning• Without ionizing radiation• Images generated using powerful magnets and
pulsed radio waves passing through the body• Data from Pt’s body used to generate image • Field strength of magnets 0.3-3.0 Tesla
![Page 21: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/21.jpg)
MR Contrast Agents• Intravenous contrast---Gadolinium chelate-based
contrast agents
• Gadolinium is a paramagnetic lanthanide that is toxic as a free metal
• Contrast to evaluate BBB, intracranial edema and hemorrhage
• Novel agents being developed as tagged Monoclonal antibodies for Molecular Imaging
![Page 22: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/22.jpg)
MR Applications• Neuro-imaging
-Excellent tool due to high soft tissue contrast resolution
-Abundant water content of CNS allows for imaging soft intracranial tissue
• Head and Neck imaging-Multi-planar capability allows for monitoring extent of
disease
-Differentiating subtle soft tissue boundaries of head and neck
![Page 23: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/23.jpg)
Aims:•Basics
•Best exam results•Appreciate the role radiology plays
![Page 24: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/24.jpg)
Densities The big two densities are:
) 1 (WHITE - Bone
) 2 (BLACK - Air
The others are:
) 3 (DARK GREY- Fat
) 4 (GREY- Soft tissue/water
And if anything Man-made is on the film, it is:
) 5 (BRIGHT WHITE - Man-made
![Page 25: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/25.jpg)
Inspiration/Expiration
![Page 26: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/26.jpg)
Anatomy
![Page 27: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/27.jpg)
Heart (continued)
![Page 28: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/28.jpg)
Lateral CXR (continued)
![Page 29: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/29.jpg)
Heart •Size of heart
•Size of individual
chambers of heart
•Size of pulmonary vessels
•Evidence of stents, clips, wires and valves
•Outline of aorta and IVC and SVC
![Page 30: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/30.jpg)
Typical Mammography Unit
Equipment is C-armSID is fixed at 24 – 26”
![Page 31: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/31.jpg)
Compression Device
Made of firm plastic
Amount of compression: between 25 and 40 pounds pressure
Compression may be uncomfortable!
![Page 32: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/32.jpg)
Digital Mammography
State of the art!
• No film or chemical processing
• Images easily sent over internet
• Much better definition
![Page 33: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/33.jpg)
Routine mammography projections
Craniocaudal (CC)
Mediolateral oblique (MLO)
![Page 34: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/34.jpg)
CT Terminology
• Attenuation is measured in Hounsfield units– Scale -1000 to 1000
• -1000 is air• 0 is water• 1000 is cortical bone
• Attenuation– Hyperattenuating (hyperdense)– Hypoattenuating (hypodense)– Isoattenuating (isodense)
![Page 35: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/35.jpg)
CT Terminology
• What we can see– The brain is grey
• White matter is usually dark grey (40)• Grey matter is usually light grey (45)• CSF is black (0)• Things that are brite on CT
– Bone or calcification (>300)
– Contrast
– Hemorrhage (Acute ~ 70)
– Hypercellular masses
– Metallic foreign bodies
![Page 36: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/36.jpg)
CT Terminology
• Window Width– Number of Hounsfield units from black to
white
• Level or Center– Hounsfield unit approximating mid-gray
![Page 37: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/37.jpg)
CT Terminology
• DICOM– Digital Imaging and Communications in
Medicine– DICOM provides standardized formats for
images, a common information model, application service definitions, and protocols for communication.
![Page 38: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/38.jpg)
Radiation Safety
• Terminology– Gy = Gray is the absorbed dose (SI unit)
• The equivalent of 1 joule/kg of tissue• Rad = radiation absorbed dose
– Sv = Sievert is the dose equivalent (SI unit)• Absorbed dose multiplied by a quality factor• Rem = radiation equivalent man
![Page 39: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/39.jpg)
Radiation Safety
• Effects of X rays.– Absorption of photons by biological
material leads to breakage of chemical bonds.
– The principal biological effect results from damage to DNA caused by either the direct or indirect action of radiation.
![Page 40: Mid Term Revision Imaging Procedure 1 Dr Mohamed El Safwany, MD.](https://reader030.fdocuments.in/reader030/viewer/2022032805/56649eea5503460f94bfbc8a/html5/thumbnails/40.jpg)
Good Luck