Metris Compressed Air Brochure UK
-
Upload
ifm-electronic -
Category
Documents
-
view
215 -
download
0
Transcript of Metris Compressed Air Brochure UK
-
7/30/2019 Metris Compressed Air Brochure UK
1/6
Innovation forcost reduction
in pneumatics.Leakage monitoring.Measurement ofcompressed air consumption.
Measuremen
tofcompressedairconsumption
www.if
m-e
lectronic.c
om
/metris
R
-
7/30/2019 Metris Compressed Air Brochure UK
2/6
MODE/ENTER SET
Decentralised monitoring, measurementand display of compressed air consumption.
Many sources,
including the cam-
paign efficient
compressed air*
clearly indicate the
growing interest
in the optimised
use of the energy
carrier compressed
air. This is a sub-
stantial saving
potential for
operating costs.
efectormetris
helps to explore
this potential.
Measurement ofcompressed air consumption
Optimised consumptionof compressed air
Allocationof consumed quantities
The integral
4-digit LED display
plus the statusLEDs allow infor-
mation to be avail-
able at the point
of monitoring.
Whether peak
consumption,
present or accu-
mulated consump-
tion: Set switch or
alarm levels can be
accessed and
programmed via
pushbutton.All settings can be
protected using
the electronic lock
function.
8 Nm3/h
12Nm3/h
5.5Nm3/h
* See
www.druckluft-effizient.de
-
7/30/2019 Metris Compressed Air Brochure UK
3/6
480
6,096
16,176
63,360
144
1,488
3,984
15,840
1.0
12.7
33.7
132.0
0.3
3.1
8.3
33.0
1.8
20.8
58.5
235.2
1.2
11.1
30.9
123.8
1
3
5
10
Hole
[mm]
Airloss
at6 bar[l/s]
Airloss
at12 bar
[l/s]
Energyloss
kWhat
6 bar
Energyloss
kWhat
12 bar
Costat
6 bar
[EUR]
Costat
12 bar
[EUR]
The installation
of several measur-
ing points in the
compressed air
system clearly
shows where and
how much com-
pressed air is con-
sumed. Thus the
consumption can
be allocated to
production
processes or prod-
ucts for optimising
cost structure.
Decentralised
location ofefector
metris in the sup-
ply pipe to the
individual
machine unit.
Location of
efectormetris in
the supply pipe
prior to distribu-
tion to several
installations or
machine units.
eakage monitoring
Two reliable indications of air leakageare the increase in consumption of com-pressed air with unchanged machine
load and the continuing consumptionof compressed air when the machine isno longer in operation.
Leakage at a glance.
The compressed air meters integratedpipe length ensures easy mountingand high measurement accuracy.
Easy to mountin the supply system.
R
Annual energy costs due to leakage:
kWh x 0.06 EUR x 8000 operating hours/a.;
Source: www.druckluft-effizient.de
-
7/30/2019 Metris Compressed Air Brochure UK
4/6
MODE/ENTER SET
From now on: Accurate monitor-
ing of compressed air consump-
tion with efector metris.
The low purchase price makes it
possible: To measure compressed
air where it is used.
Even very small leaks are detect-
ed and can be repaired in good
time.
The quantities consumed can be
directly allocated to the relevant
production units.
In situ display of total or current
consumption.
Switching, pulse or analogue
outputs for further external
processing.Determine maintenance intervals
depending on consumption.
Measurement free from pressure
loss due to a special design of
the measuring probes.
Response time in the millisecond
range.
Calorimetricmeasuring principle
Integrated
display fordirectindication ofconsumption.
Even small leaks
can cause unneces-sary electricity
costs of several
thousand Euro
per year.
The calorimetric
principle measures
the standard
volume flow
irrespective of
temperature and
pressure quickly
and over a wide
measuring range.
Leakage detection, energy costreduction and environmental protection.
-
7/30/2019 Metris Compressed Air Brochure UK
5/6
*SP = switch point, **ASP = analogue start point, ***AEP = analogue end point
Application
Electrical design
Connection
Compressed air in industrial use
DC PNP
4-wire
Technical data efector metris
Output 1
Output 2 (programmable)
Operating voltage [V]
Current rating [mA]
Short-circuit protection, pulsed
Reverse polarity/overload prot.
Analogue output
Pressure resistance [bar]
Medium temperature [C]
Power on delay time
Response time [s]
Measuring error in themeasuring range
Repeatability
Function displaySwitching statusDisplay
Connection
19...30 DC
2 x 250
4...20 mA (max. 500 )
16
0...60 (max. 90 % relative air humidity)
0.5 s
< 0.1
(3 % measured value + 0.3 % final value of the measuring range)
1 % of the measured value
2 x yellow4-digit alphanumeric display
Operating temperature [C] 0...60
Protection IP 65 III
Material housing PBT-GF20; PC; Makrolon; stainless steel (304S15); Viton
Material sensor stainless steel (304S15); ceramics; PEEK; polyester
M 12 connector
2 x NC /NO programmable or 1 x NC /NO programmableand 1 x analogue 4...20 mA
or 1 x NC/ NO programmable and 1 x pulse output (1 pulse = 1 l or 1 m3)
Measuring range[Nl/min / Nm3 / h]
Setting rangeSP* [Nl/min / Nm3 / h]ASP** [Nl/min / Nm3 / h]AEP*** [Nl/min / Nm3 / h]
Pipe connection
Order no.
Sockets
DescriptionOrder
no.
2 m PUR, M 12 straight, without LED E10906
5 m PUR, M 12 straight, without LED E10907
76,
8
45
LEDdisplay
programmingbuttons
R
90
300
16,1
21,3
M12x1
100
111,5
Example: SD6000
4...1,250 /0.25...75
12.5...3,750 /0.75...225
6...1,250 / 0.4...750...938 / 0...56.3
313...1,250 / 18.8...75
19...3,750 / 1.1...2250...2,812 / 0...169
937...3,750 / 56...225
DN15 DN25
SD6000 SD8000
0.039...11.67 x 103/2.3...700
0.0...11.67 x 103/ 4...7000.0...8.75 x 103/ 0...525
2.92...11.67x103/175...700
DN50
SD2000
22.2...8,000 /1.3...400
30...6,670 / 2...4000...5,130 / 0...307.5
1,710...6,670 / 102...400
DN40
SD9000
-
7/30/2019 Metris Compressed Air Brochure UK
6/6
Over 70 locations worldwide at a glance at www.ifm-electronic.com
ifmarticleno.
7511082
Wereservetherighttomaketechnicalalterationswitho
utpriornotice.PrintedinGermanyonnon-chlorineblea
chedpaper.01/05
ifm electronic gmbh
Teichstrae 4D-45127 EssenTel. 02 01 / 2 42 20
Fax 02 01 / 2 42 22 00e-mail:
http://w
ww.ifm-electro
nic.com
visitou
rwebsit
e
Position sensors
Proximity switches
Actuator sensors
Photoelectric sensors
Photoelectric systems
Incremental andabsolute encoders
Evaluation systems
Power supplies
Fluid sensors
and diagnostic systems
Inductive sensors for valves
Level sensors
Flow sensors
Pressure sensors
Vacuum sensors
Temperature sensors
Diagnostic systems
Networkingand control
Industrial communicationAS-Interface
Control systems
ifm electronic