Metering Pump Spare Parts Replacement

Transcript of Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a...

Page 1: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Metering Pump Spare Parts Replacement

Metering Pump Spare Parts Replacement

Page 2: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Pump Components (Metering Pump)

• Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump is plugged into a properly grounded receptacle.

• Be sure the pump is properly anchored before connecting tubing and other pump components

• Pumps are traditionally installed one of two ways, Suction lift and flooded suction.

Page 3: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Pump Components (4-FV)

The Four function valve

(4-FV) mounts on the

discharge side of pump head

4 functions of valve

• Back pressure (yellow)

• Anti-siphon (yellow)

• Pressure relief (black)

• Line drain (black)

Page 4: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Pump Components (Foot Valve and Weight)

• The foot valve is positioned at the bottom of the supply tank

• In suction lift applications the Foot valve is used to prevent loss of prime

• A filter screen prevents debris from entering the pump

Note: Position foot valve vertically

Ceramicweight

Foot valve

Filterscreen

Page 5: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Pump Components (Injection Check

Valve)• The Injection check valve

is positioned at the end of the discharge tubing line

• A 1/2” NPT thread allows the ICV to be piped directly into a pressurized line

• The flapper valve prevents deposits from clogging the injector

Note: Install on underside of pipe

Flappervalve

1/2 NPTpipe thread

Page 6: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Pump Components (Discharge and Suction Tubing)

• Most pumps come equipped with flexible PE tubing for the discharge and suction connections

• In some liquid ends vinyl tubing is offered. This low pressure tubing should be used on the suction line only.

• In applications requiring pipe connections, fittings are supplied with NPT pipe threads. No tubing is supplied with these pumps.

• Optional black UV tubing is available for UV applications

Page 7: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Spare Part Replacement Kit

• Spare part kits, replacement tubing and other pump components can be obtained from your local pump supplier

• Spare parts should be replaced annually

• It is also recommended that discharge and suction tubing be replaced annually

Page 8: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Protective Clothing and Eye Protection

• CAUTION: Wear protective clothing and eye protection when working on or near all chemical metering pumps.

• A full face shield and long chemically resistant gloves and apron are recommended.

• Check MSDS sheet for other precautions

Page 9: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

De-Pressurize Liquid End

• Turn pressure relief knob (black) 1/4 turn

• Discharge line is now de-pressurized

• Solution should flow back down discharge line and out return line back to supply tank

Page 10: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Remove Discharge Tubing

• Remove discharge tubing

• Turn coupling nut counter-clockwise to remove.

• Remove tubing from fitting by pulling up.

Page 11: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Remove Return Line Tubing

• Remove return line• Turn coupling nut

counter-clockwise to remove.

• Pull tubing out of valve

Page 12: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Remove 4-FV From Head

• Remove 4-FV• Turn 4-FV counter-

clockwise to remove

Page 13: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Remove Discharge Cartridge Valve (Check Valve)

• Remove discharge cartridge valve or check valve ball and seal ring from pump head

Page 14: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Remove Cartridge Valve (Check Valve)

• Remove suction fitting by unscrewing counter -clockwise

• Remove cartridge valve or check valve ball and seal ring from pump head

Page 15: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Remove Pump Head

• Remove pump head• Remove the four

screws that mount the pump head

Page 16: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Remove Old Pump Diaphragm

• Remove the pump diaphragm by turning it counter-clockwise

Page 17: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Remove Old Diaphragm and Disk

• Remove the diaphragm and backing disk

• Discard diaphragm and inspect disk for damage

Page 18: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Remove Shaft Seal

• Remove the shaft seal using needle nose pliers. Pull shaft seal out and discard

Page 19: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Replace Shaft Seal

• Install the new shaft seal using a large hollow pen cap or wrench socket large enough to clear diaphragm shaft

• Push seal in place

Page 20: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Replace Pump Diaphragm

• Install the disk and new pump diaphragm by turning it clockwise

• position diaphragm in and out until the center of the diaphragm is flush with outside of the spacer housing

Page 21: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Replace Pump Head

• Re-install the four screws that mount the pump head loosely

• Tighten the screws gradually in a crisscross pattern until all screws are tight

Page 22: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Compression Washer Replacement

• Compression washers are located in fittings and function valves

• If necessary, remove washer with small screw driver

• Install new washer by hand by pushing into fitting

Page 23: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Correct Installation of Cartridge Valves

BOTTOM

TOP

Directionof Flow

CORRECTPOSITION

INCORRECTSmoothside

Ballseatside

Page 24: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Cartridge Valves vs. Ball and Seal Rings

Directionof Flow

BALL& SEAL

RING

EXAMPLE: FOOTVALVEFOR LARGER

PUMPS

EXAMPLE: FOOT VALVEFOR SMALLER

PUMPS

CARTRIDGEVALVE SHOWN

DIS ASSEMBLED

Page 25: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Replace Suction and Discharge Cartridge Valves (Check Valve)

• Install new cartridge valves or check valve balls and seal rings in pump head

• Place o-ring on cartridge valve

• Position ball seat side of cartridge valve toward floor

• Hand tighten fittings do not use pliers of pipe wrench

Page 26: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Injection Check ValveSpare Parts

• Install new Injection check valve components

• Screw fitting down hand tight. Do not use pliers or pipe wrench

SPRING

BALL

PTFE SEAT

O-RING

Page 27: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

• Install new cartridge valve and o-ring

• Place o-ring on cartridge valve

• Position ball seat side of cartridge valve toward floor

• Screw fitting down hand tight. Do not use pliers or pipe wrench

Foot Valve Spare Parts

CARTRIDGEVALVE

O-RING

Page 28: Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.

Install New Pump Tubing

• Replace all discharge and suction tubing annually

• Contact your local pump supplier for replacement tubing

• Do not re-start pump until all tubing connections have been made