Medalist i3070 08.30p software release

34
Medalist In-Circuit Test 08.30p Software Release Agilent Confidential Medalist i3070 08.30p Software Release Page 1 July 2012

Transcript of Medalist i3070 08.30p software release

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

Medalist i3070 08.30p

Software Release

Page 1 July 2012

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

Agenda

1. Software Milestone

2. What’s new in 08.30p?

3. How to get 08.30p?

Page 2 July 2012

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

Agenda

1. Software Milestone

• Software Release Milestone

• Change Request List

2. What’s new in 08.30p?

3. How to get 08.30p?

Page 3 July 2012

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

Current Product Engineering (CPE)

08.10p

SW

Continuous Improvement & Innovations

i3070

and

i3070

S5

2009 2010

08.00p SW

Utility Cards

& ASRU N

2011

July 2012 Page 4

Medalist i3070 Software Release Milestone

Jul

2012

Oct

Agilent LED TestAug

08.20p

SW

08.30p SW

(XP & Win7)

Win 7Nov

08.40p SW

(XP & Win7)

April*

New Features 08.20p 08.21p 08.30p

High-Power (N5747) Power Supply

High Voltage Zener

Windows 7 (32 bits)

Windows 7 (64 bits*)

LED Test

External DLL call

rp5800 PC

* Subject to change

08.21p

(XP & Win7)

NovFeb

2013

Aug

135 Change Request

Ship - 1 Aug 2012.

Field distribution - 1 Aug 2012

SUS distribution - 17 Sep 2012

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

July 2012 Page 6

Appendix: Change Request List - 1

CR ID TitleCR27877 Unable to compile analog cluster (magic test) at PBD

CR29362 07.00pf: Board Consultant: Range for Tolerance Multiplier Is IncorrectCR33453 i3070 : ERROR!! result from Browser Locator Find Probe action

CR33602i3070: Controllerloop causes measurement timeout in analog portion of mixed test

CR33604i3070SW: Panel testplan subroutine Program_Flash does not declare variables True

CR3384208.10: Support Info-Readme Under Control Panel For Agilent IO 15.5 not working

CR33922 08.10: CA: Tested in parallel incorrect coverage countCR33962 Digital setup editor would shutdown CR33990 customer requests an ability to call DLL command libraries CR34045 08.20:Engineer GUI, More then one "GL" boxes can be checked

CR34048 program memory exceeded

CR34080 08.20 DGN Display Failure issueCR34085 08.20 : Browser : Personality Pins cannot browseCR34090 parse board and board_xy for conflicts when loading in operator GUICR34099 Get statement automatically writes name in the title bar of BT-BasicCR34100 Automated display backslashes as slashes in BT-Basic Title

CR34111 preferences setting in the board directory and User home directory CR34116 To enable ASRU N to work under UNIX as ASRU C / D

CR34119 Should auto check "En" option if sense "A" is used CR34126 08:20 Agilent Coverage Analyst got wrong RevisionCR34127 08.20: TTFXT_HP6621 compile config failed

CR3413308.20: Engineer GUI : Incorrect message for ar value of less than 18 for HVZ

CR34136symlink & iNode not working in TTDB GUI Panel test strategy when using NFS

CR3413908.20p: HVZ_TTDB mark permanent or commented cause prepowerederase in testorder

CR34142 digital test reports error from AUX which is not used

CR ID TitleCR34143 quick report doesn't find all testsCR34150 ASRU N diagnostics failure 2824CR34152 08.20a: Support Info closes automaticallyCR34154 Alternate PC portable based dongle pin card programmingCR34156 To remove MIL-STD-45662A wording from NIST CAL testplan CR34159 08.20p "load board" command takes longer time to finishCR34162 3070SW: icap card: fixture auto- unlocked during reboot.CR34163 Add lost heart beat message and time stamp in pmlog

CR34165Data polling in flash isp test does not work with xtp firmware version 10071517

CR34166 enhance ASRU cal 4395 and 4396 to write and check tracking featureCR34167 i3070: Enh Req to inhibit auto-converting to Multiple Board Versions

CR34170i3070 8.20p: need to select FPY/WPR view each time Operator GUI is launched

CR34175DC capacitor test causing subsequent test with "ed" option failed or timeout

CR34177 NPM Issue encounterred in 08.20pCR34179 08.20: ASRU N Diagnostic Failure T2824 - Improve yieldCR34180 08.20p: Wrong Error message for ASRU CalibrationCR34181 Pushbutton Debug Window closes when Marking a Test as permanent.

CR3418208.20b: By default, FPY and WPR should be tick check after operator GUI start

CR34183 08.20b: No revision info display in i3070 Medalist

CR3418508.20b: Installed Window Service for Unix cause issue in control of testhead

CR3419008.20: CA: BScan,CE and SN not reported as Test Technique used in Executive Sum

CR34191 Coverage Analyst not handling Preshorts and Powered Analog correctly

CR34192NIST Calibration Testplan uses Wrong Units for Temperature in Report Header

CR34200 i3070 8.x: BT-Basic Internal Error -13 at 'select boards on panel'

CR34204Relay Locator Diagram for unmux hybrid shows incorrect reference designators

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

Appendix: Change Request List - 2

July 2012 Page 7

CR ID Title

CR34208 Xvision Install error if i3070 sw is removed and re-installed 0820p

CR3420908.20p: BSDL parser does not flag single-ended, differential pins as errors

CR34214 4 Languages Software License Term

CR34215Making Diagnose Relay licensing requirement same for Mux and Unmux

CR342163070: The BSDL compiler does not issue a warning for part 4 of rule B.8.18.4u).

CR34218 08.30: Default xtp.xsvf file is 02020812_1 instead of 11060116_1

CR3421908.30: Installation: Missing link (file) to Medalist i3070 software install help

CR3422008.30: DGN new Test 8 (cal date & stored data) implemented on Unmux

CR34221 08.30 : DGN : Request to identify module # for T4396

CR3422308.30 : Expired cal: Calibration Message for testh is 1 is incorrect & clearable

CR34224 08.30:No Program_pin_card lic "Program Cards" is still enabled in DGN

CR34227 i3070: ENH REQ Board Consultant should display more than 5 boards

CR34228i3070 8.x: ENH REQ board setting for IPG to write AC cap test or DC cap test

CR34229i3070: ENH REQ FXT53 WARNING message much obvious for insufficient access

CR34230 08.20: Hang on xvision uninstallation of 08.20p

CR34231 With rev 0820p it's not possible to open Setup Editor

CR34236 i3070 8.x: Conversion Tool needs updating for 8.x software

CR3423708.30:Oper GUI: Implement saved setting to show/hide FPY/WPR on Chinese locale

CR34239 i3070 08.xx: Improve file checking efficience over network

CR34240 I3070HW: Nasru Cards are reporting 3374/3376 Errors.

CR34248Testplan statements itb$ and num cause missing characters on display and in logs

CR ID Title

CR34249Mixed Test failing line numbers and calling sequence not displayed in PBDebug

CR34252 i3070 8.00p: Unility Card mux power supply wiring failed

CR3425408.20: CA: Panel : Wrong report:tested devices reported as untested & vice versa

CR34258 i3070: ConnectCheck learned value not save in PBDebugCR34259 08.20e: PBD : Internal Error -11 opening a digital test

CR3426008.20e:UnMUX:T342 Control 3 Real Math Error running the Analog_Tests subroutine

CR3426208.20pe: Angela board; Bt Basic encounter internal error when call Analog_Test

CR34263 i3070: Actel STAPL not compatible with 3070 PLD ISPCR34265 extra line of 'sequencer halted' in digital failure messageCR34266 08.20e : vcllib.exe error during lib compileCR34268 IPG select inaccessible nodes in .discharge testCR34269 i3070: ICT Browser and Engineer GUI "Error in File Type: board"CR34270 breaking recycle to fail for polarity test causes Pascal system error 8

CR34271 Display Graphics menu is grey out for Polarity test in Pushbutton debugCR34276 08.30 Uninstall, SCO Vision hang during uninstallCR34277 08.30p Engineer Gui AIC Left Table duplicate column for CPKCR34278 08.30p Installation,AgilentIO encounter error 1722 if use fresh WinXP HDCR34279 Need the maximum Instruction Register length to be increasedCR34281 08.30p Engineer GUI - Missing Permanent column in AIC Left Table

CR3428208.30p Testh power off - Failure in Medalist operator gui and Btbasic window

CR34288 08.30 BtBasic, GPIB timeout when do 'testhead is 1'CR34290 Coverage Analyst hangs at Binding Test and Board Data

CR3429108.30 Wrong Control XTP seq FPGA version, expected version is 11060116_1

CR34292 3070 GUI hangup on 2lvl fn calls

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

July 2012 Page 8

Appendix: Change Request List - 3

CR ID TitleCR34293 Stapl compiler does not parse arithmetic assignment properlyCR34294 N6751A DUT power supply fail DGN Test number 2340-DPS ground faultCR34295 08.30: Program Asru encounter software internal error

CR34297 8.30p IPG Test Consultant GUI -Selected Directory Contents issueCR34301 Timer functions to capture test time at board or sub-test level CR34305 Needs auxconnect that does not release when press STOP CR34306 Histogram failed to generate on failing tests (i3070 Medalist)CR34308 Quick Report does not report new hardwareCR34311 Enable back ps6751 CR34312 Control XTP Psync ErrorCR34318 Browser cannot display a panelized board in Bank 1CR34319 08.30: Cannot launch BScan Chain ViewerCR34321 08:30: Testhead cannot boot successfully in RP5800 controllerCR34322 Incorrect .discharge file causes relay damage

CR34323debug end causes bt-basic hang when digital waveform window is the 4th window

CR34324 08.30: Operator GUI :SpecialAux --> Set : File or directory not found CR34325 08.30: Special Aux connect feature implementation

CR34326 08.20: add support for boundary-scan 1149.8.1 standard in ballot

CR3432708.20: Unconnected test receiver does not capture data for differential pairs

CR34328Allow CET for panel board with even no. of boards when CET Gnd wired to XTP Gnd

CR ID Title

CR34329 Recommend new kind of wiring for CET Card to prevent CET burnoutCR34330 Support uVTEP with license controlCR34334 08.30: Outdated Agilent copyright year info CR34336 08.30: ASRU N Diagnostic Failure T2283 - Improve yieldCR34337 Enhanced 6M 12M hybrid mixable in testhead

CR34338 08.30: To add an error variable parameter for external dll commands

CR3433908.30p IPG TestConsultant - Run Test Cell Manager window caption wrong

CR34340 08.30p BtBasic caption missing "\"CR34346 Boolean array assignment and syntax error line number displayCR34348 08.30: Q-Stats report Histogram type encounter hang

CR34349 08.30: PBD_Edit menu execute Copy and Paste failed and cause GUI hang

CR34350 08.30: PPU_without credit button still can load board and run ICT test

CR34357 08.30p - Installation microsoft .net 3.5 maintenance mode screenCR34358 08.30: Unable to execute A3070toI5000.pl successfully

CR34359 08.30: PBD_after autodebug NPM execute to fail have internal error -11CR34360 TCM Account Starts in Program Monitor ModeCR34364 HVZ test is generated for ASRU-C configCR34365 08.30: PPU_Widget bar "stop" not functionCR34366 08.30: Compile error of Actel STAPL file

CR34384Improve IPG discharge with more conservative calculations for .discharge file

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

Agenda

1. Software Milestone

2. What’s new in 08.30p?

• Capability and Functionality:

• Technology Upgrade:

• Productivity Enhancement:

• Licenses enable features:

3. How to get 08.30p?

Page 9 July 2012

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

1. BT-Basic DLL integration feature Overview

Page 10 July 2012

i3070 DLLs

Functional

Test

Production

Mgmt SW

Flash Prog

Commands & Syntax Example:

dllload “<dll-name>”, <dll-handle> dllload “getboard_data.dll”, Handle_1

dllcall <dll-handle>, “<custom function name>”, [<return

number>], [“<return string>”]; [“<custom parameters>”]

dllcall Handle_1, “blank_check”,

Var_1, ErrMsg$; “0, 0xffff”

dllunload [<dll-handle>] dllunload Handle_1

Ext_App_DLL feature license is needed to enable and

execute the following three new commands:

Wrapper DLL is needed to export the standard APIs BTBasic_DLL_Call() for BT-Basic to call, and

redirects the call to 3rd party software

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

Programming Model Overview

Generic flow of BTBasic executing dllcall, through the DLL wrapper to the DLL functions:

Page 11 July 2012

BT-Basic

dllload(“UtilWrapper.dll”, Handle_1)

dllcall Handle_1, “DoSimFun1”,

Var_1, ErrMsg$; “100”

Calls

DLL wrapperB

BTBasic_DLL_Call(“DoSimfunc1”,

“100”, ErrMsg,

Var_1)

DoFun1(int nCount)

{ // perform some algorithm }

Calls

Customer’s DLLs

BT-Basic

…dllcall Handle_1, “blank_check”,

Var_1, ErrMsg$; “0, 0xffff”

DLL wrapperA

BTBasic_DLL_Call(“blank_check”, “0,

0xffff”, ErrMsg, Var_1)

Func DLL

blank_check(0, 0xffff)Calls Calls

Customer’s DLLs

1.

2.

3.BT-Basic

dllload(“UtilWrapper.dll”,

Handle_1)

dllcall Handle_1, “DoSimFun1”,

Var_1, ErrMsg$; “100”

dllcall Handle_1, “ExDllFunc1”,

Var_1, ErrMsg$; “0,

0xffff”

dllunload(Handle_1)

Calls

UtilDLL

ExDllFunc1(0,

0xffff)

DLL wrapperC

BTBasic_DLL_Call(“DoSimfunc

1”, “100”,

ErrMsg, Var_1)

DoFun1(int nCount)

{

// perform some algorithm}

BTBasic_DLL_Call(“ExDllFunc

1”, “0, 0xffff””,

ErrMsg, Var_1)

Calls

Customer’s DLLs

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

External DLL call (Sample)

Page 12 July 2012

Example:

- Custom function Sum() in the Sample.DLL

- In BT-Basic, enter dllcall Dll-handle “Sum”, RetrunNum,

ReturnString$; “10,20,30”

- BT-Basic will call the function BTBasic_DLL_Call() with

functionName “Sum” and parameters “10,20,30”.

- The parameters string “10,20,30” is converted into integer

array and passed to function Sum().

- The Sum() calculate the sum of the elements of the integer

array, and return back the result to caller.

- The value of ReturnNum will be 60 and the content of

ReturnString$ will be "Function \"Sum\" has been called!"

Specification:

1. User Wrapper DLL – Must be C++

2. Ext_App_DLL feature license needed during runtime

Default:

• example:

dllload “Demo.dll”, Handle

Then, Software search the DLL at

Agilent_ICT\ext_dev

User specify full path

• example:

dllload

“Agilent_ICT\boards\demo\Demo.dll”,

Handle

Then, software search the DLL at

Agilent_ICT\boards\demo

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

BT Basic - External DLL (Demonstration)

Page 13 July 2012

1. Demo.dll – updating Pass/Fail status of

the DUT to the “demo.mdb” database.

2. The testplan_demo is updating test

status for board with SN „0001‟ and

‟0002‟ .

3. Initial test status in database, „0001‟

and „0002‟ are passed.

4. Assumed „0001‟ Pass and „0002‟ Fail.

5. Getting the status of S/N 0001 from

database and update the result .

6. Getting the status of S/N 0002 and

update accordingly.

7. SN0002 updated as FAIL.

8. Finally, the testplan unload the DLL

from memory.

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

July 2012 Page 14

2. Agilent i3070 LED Test solution

Cost effective LED test at ICT.

An industry FIRST! An Agilent innovation using proprietary architecture to

measure LEDs with blazing speed – fastest in the industry.

Accurate and repeatable color and intensity measurements ensures

consistently reliable results.

Fastest analysis speed saves time and money.

Highest signal-to-noise performance enables you to test the widest range of

LEDs.

ORi3070 LED Test Box i3070 LED Test Card

N1

80

7A

Uti

lity

Car

d

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

July 2012 Page 15

Agilent i3070 LED Test solution

Fast, accurate, flexible and repeatable.

• Proprietary architecture will send digital stimuli, measure the LEDs‟ color and

intensity and returning results of up to 128 LEDs in less than 1.3 seconds.

• Acquires the peak, base or instantaneous wavelengths of the LED color and

returning the measurement in nanometers (nm).

• Measures the LED intensity(luminosity) in μW`/cm2

• Uncompromising repeatability achieved through a shroud tube design to shield

noise (ambient light) from surrounding LEDs.

Throughput

Up to 128 LED sensors in 1.3s

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

July 2012 Page 16

Agilent i3070 LED Test solution

Release 8.3

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

Agenda

1. Software Milestone

2. What’s new in 08.30p?

• Capability and Functionality:

• Technology Upgrade:

• Productivity Enhancement:

• Licenses enable features:

3. How to get 08.30p?

Page 17 July 2012

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

1. RP5800 PC

Page 18 July 2012

Rp5700 RP5800

Operating

System

Microsoft Vista32B

Downgrade to XP32B OS

or

Windows 7 Pro 32B

Microsoft Windows 7 Pro

32B

Processor

Intel® Dual-Core

Processor E2160 (1.80

GHz, 1 MB L2 cache,

800 MHz FSB)

Intel® Core™ i5-2400

(3.10 GHz, 6 MB cache,

4 cores)

Memory

HP 2GB PC2-5300

(DDR2-667) Memory - 4

DIMM Slot

4GB PC3-1333MHz

DDR3 SDRAM (Max

16GB)

GraphicIntegrated Intel Graphics

Media Accelerator 3000

Integrated Intel HD

Hard Drive 160GB SATA 3.0GB/s250GB

SATA (7200 rpm)

DVD 16X SATA DVD-WriterSATA SuperMulti DVD

writer

NetworkBroadcom NetXtreme

Gigabit PCI-E Adapter

Integrated Intel

82579LM

Intel PRO 1000 CT GbE

(optional)

Ports2 Rs232 ; 6 USB ; 1

parallel

7 USB 2.0

1 24V powered USB

2 RS-232

Part number Description

0960-3030 rp5800 with Windows 7 OS without

ICT Software

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

rp5800 Vs rp5700 Test Time

Page 19 July 2012

Windows 7 Rp5700 rp5800

Test Type sec secPreshorts 0.248 0.269Shorts 0.250 0.246

Unpowered Analog 0.251 0.248

Vectorless Test 0.467 0.465

Polarity Test 0.127 0.141

PS Setup 0.447 0.454

BScan Powered Shorts 25.133 25.134

BScan Interconnect 0.193 0.198

BScan Incircuit 4.871 4.879

Bscan Silicon Nails 0.033 0.044

Cover Extend 0.598 0.409

Flash ID 0.017 0.015

Flash Erase 10.044 10.043

Flash Blank 0.018 0.018

Flash Program 0.048 0.046

Flash Verify 0.040 0.038

Flash CRC 0.162 0.161

CPLD 6.338 6.335

Total Digital Test 16.793 16.783

Analog Functional (Mixed) 0.053 0.055

Total Test Time 66.131 65.981

LOAD BOARD Time

(Across Network)

LAN Card Setting

RP5700 (08.21p)

RP5800(08.21p)

Auto (100M)

4.2086 sec 2.75625 sec

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

2. Installing Medalist i3070 08.30p

Page 20 July 2012

Windows 7 32-bit and Windows XP 32-bit OS

• Available for Testhead and Test Development Workstation

Windows 7 64-bit OS

• Available for Test Development Workstation

Windows XP OS

• Prompt to update Third Party Software to1. Nutcracker 9.4

2. Xvision 731/MKS X Server

3. Agilent IO 16.1

4. ScanWorks 3.14

5. Bootp Turbo

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

Agenda

1. Software Milestone

2. What’s new in 08.30p?

• Capability and Functionality:

• Technology Upgrade:

• Productivity Enhancement:

• Licenses enable features:

3. How to get 08.30p?

Page 21 July 2012

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

1. Special AUX Connect

A new set of BT-Basic special aux commands:-

run, stop, abort, start, and wait for start

Page 22 July 2012

• declares relay 5 to be a special relayspecial aux set 5

• closes the relayspecial auxconnect 5

• opens the relay special auxdisconnect 5

• Clear mappingspecial aux clear 5

- Cannot be controlled with the auxconnect and auxdisconnect commands

- Error occurs if

Not yet declares as special

Close or Open the relays that mapping has clear

Specified as vacuum ports in the testhead config file.

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

2. Global setting for Large Capacitor

Page 23 July 2012

New Global option to allows IPG to write DC mode capacitor

To use it; insert Large Capacitor DC Mode On or Off in board file.

Global Option in Board File Capacitance IPG will generate:

Not specified >= 1000 uF AC mode capacitor test

Large Capacitor DC Mode On >= 1000 uF DC mode capacitor test

Large Capacitor DC Mode Off >= 1000 uF AC mode capacitor test

Not specified < 1000 uF AC mode capacitor test

Large Capacitor DC Mode On < 1000 uF AC mode capacitor test

Large Capacitor DC Mode Off < 1000 uF AC mode capacitor test

Can enable through Board Consultant.

Backward compatibility

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

3. Discharge algorithm Enhancement

Page 24 July 2012

Software Rev Enhancement Remark

08.20p Entry Voltage <= 2v for discharge

08.30p Improve IPG discharge with more

conservative calculations for

.discharge file

APG_DISCHARGE_ROBUST = False

(conservative) – Default for 08.30p and later

APG_DISCHARGE_ROBUST = True (actual)

For 08.20p or earlier

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

4. CET New Wiring Recommendation

Page 25 July 2012

VTEP Mux cable

CET USB cable

(with ferrite coil)

CET LEM_A,R,M &

Power

VTEP Mux card

CET card

1

220

19

CET Power

Data +

USB GND

USB VCC

Data -

LEM_ALEM_R

LEM_M

CET GND

HYBRID GND

1

220

19

CET Power

Data +

USB GND

USB VCC

Data -

LEM_ALEM_R

LEM_M

CET GND

Old Wiring New Wiring

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

5. Others Important Changes

• Unmux – Relay diagnostics license replaced by Advanced DGN

• Load Board time has been improved.

• Solved “Pushbutton Debug Window closes when Marking a Test as permanent”.

• IPG no longer select inaccessible nodes in .discharge test.

• FXT53 WARNING message for insufficient access is more visible.

• STAPL compiler (JDEC standard) is enhanced to support Actel devices. (example: CPLD devices)

Page 26 July 2012

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

Agenda

1. Software Milestone

2. What’s new in 08.30p?

• Capability and Functionality:

• Technology Upgrade:

• Productivity Enhancement:

• Licenses enable features:

3. How to get 08.30p?

Page 27 July 2012

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

1. Mixed Hybrid 6 MPs and 12 MPs

Example 1 Example 2 Example 3 Example 4

LicensePower-Test Upgrade

Hybrid Std Adv Mix

12M Modifier

20M Modifier

Hybrid Std Adv Mix

12M Modifier

20M Modifier

Hybrid Std Adv Mix

12M Modifier

20M Modifier

Hybrid Std Adv Mix

Actual Hardware Hybrid Standard

Hybrid Advanced

Hybrid Standard

Hybrid Advanced

Hybrid Standard

Hybrid AdvancedHybrid Advanced

System config fileChange to match

actual hardware

Change to match

actual hardware

Change to match

actual hardwareNo changes

Board config Hybrid Standard Hybrid Standard Hybrid Advanced Hybrid Advanced

Test Board? Yes Yes Fail Load board. Yes

Page 28 July 2012

Expectation & Condition:1. Is Not standard offering; for installed

based customer that has challenge in

asset management.

2. BDM approval needed for temp license on

case by case basis

3. Use model not listed in User Online Docs

4. Follows slowest cards if detected

5. No impact to Autoadjust and DGN tests

License enable feature

Allow Hybrid 6MPs and 12MPs (only)

to be mixed in the system.

Available on 08.30p or later

Time based license only

(Hybrid_std_adv_mix feature)

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

BT-Basic commands to enable the

ASRU N card to function as Rev “C” in

Unix or Rev “N” in Windows

Available on 08.30p or later

Time based license only

Unix

Controller

Page 29 July 2012

2. Enable ASRU N as ASRU C for Unix

Condition & Expectation:1. Is Not standard offering; is targeted for

Dual Boot environment

2. BDM approval needed for temp license on

case by case basis

3. DGN failures expected in Rev “C”. No fix is

required.

4. No software support in Rev “C” (Unix)

5. Use model not listed in User Online Docs

6. NIST/ASRU cal must be done in ASRU Rev

“N”. No support for Rev “C”.

7. No issue for Autoadjust in Rev “C”

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

BT-Basic Command

Page 30 July 2012

Output:

0 0-0 1-0 2-C 3-C

asru state - 0/C/N. 0 means No cardModule No. 0 – 3.

Command result. 0-successful, non-zero–Failed

Command Example:

program asru c/n, State$, Error program asru c, Rtn$, Err

program asru c/n, State$, Error; option program asru c, Rtn$, Err; noboot

Example of subroutine:

Error = 0 | State$ ="NoState“

program asru c, State$, Error; noboot

testhead is 1, Err

if Error <> 0 then

testhead power on

end if

fixture lock

Note: State$ and Error variable position non-swappable

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

ASRU N in Rev “C” mode - DGN Test results

ASRU-N as ASRU-C DGN results (No fix is required)

Page 31 July 2012

Test# Descriptions Reason

T2346 Source Output Resistors and MOA Feedback Resistors. transformer circuitry removed in ASRU-N

T2711 Interconnect MUX Relays K801, K802, K803 and K804 removed in ASRU-N

T2713 Interconnect MUX Relays K809, K810 and K817 removed in ASRU-N

T2720 SUBMUX S-bus Relays Closed Changed test source voltage to 0.05V from 0.1V for

ASRU-N 2-ounce copper layout

T2722 SUBMUX I-bus Relays Closed Changed test source voltage to 0.05V from 0.1V for

ASRU-N 2-ounce copper layout

T2724 SUBMUX L-Bus Relays Closed Changed test source voltage to 0.05V from 0.1V for

ASRU-N 2-ounce copper layout

T2726 SUBMUX A-Bus Relays Closed Changed test source voltage to 0.05V from 0.1V for

ASRU-N 2-ounce copper layout

T2728 SUBMUX B-Bus Relays Closed Changed test source voltage to 0.05V from 0.1V for

ASRU-N 2-ounce copper layout

T2091 SRC dc accuracy lo/hi current mode unloaded(-10 V) Marginal failure

T2311 K854, K855 open relay tests Marginal failure

T2312 K748, K761 open relay test Marginal failure

T2314 K747 + K760 close relay test transformer circuitry removed in ASRU-N

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

3. Control XTP firmware

Page 32 July 2012

1. New Control XTP firmware version 11110111_1.xsvf as a backup file.

2. To solve “T313 Control card timeout waiting for Psync signal error” that

encountered on some Control XTP cards with NEC 2Mx8bit SRAM.

3. No change is needed if you didn’t encounter the Psync issue with the

existing xtp.xsvf (110601116_1.xsvf).

To use Control XTP firmware version 11110111_1:

1. Locate the file C:\Agilent_ICT\lib\xtp.xsvf and rename it

as 110601116_1.xsvf.

2. Locate the file C:\Agilent_ICT\lib\11110111_1.xsvf and

rename it to xtp.xsvf.

3. Boot up the testhead.

4. Launch the Diagnostics application.

5. Select Configuration > Programmable Card Config and

check that the Expected value is 11110111_1.

6. Click Update All (F1) button to program all the Control

XTP cards on the testhead.

7. Reboot the testhead.

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

Agenda

1. Software Milestone

2. What’s new in 08.30p?

3. How to get 08.30p?

• Access to Software and Licenses

• Redeem License

Page 33 July 2012

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

Access to Software and Licenses

Email notification informed availability of Medalist i3070 Software 08.30p

Page 34 July 2012

Access ASM Website

Add Subscription

Access Subscription

Download Documents,

SW, & redeem LicensesRequest SW Media

Shipment

i3x7x 08.30p Software Release

- Release Notes, SW Installation Guide

- ISO file (~3GB in size)

Email Notification

ICT Software Update for Installed Based customer

- Enter Order Number & Certification provided

EMT_ICT_i3070_SYS

EMT_ICT_i3070_TDW

ICT Software Updates for the Field and IDC

- EMT_ICT_FIELD (if you have subscribed, proceed with the next step)

Installed customer select “UPDATE KIT I3X7X 08.30p” to see the overview.

Field and IDC partners select “Update kit of i3x7x 08.30p for field only” to see the overview.

Login to ASM

• https://software.business.agilent.com/asm/

• First time user, please register for an account

Medalist In-Circuit Test 08.30p Software Release

Agilent Confidential

Redeem Ext_App_DLL feature license

Page 35 July 2012

1. Get License assign Mac address

2. Specify your email address

3. License file will be emailed

immediately

- An added value feature for 08.30p software release.

- Distributed to user as FOC with testhead SUS only.