ORM 9, Geneva, May 14 -16, 2014 Evolution of Measurement Capabilities + cooperating networks.
measurement capabilities and valuable options DMS 2 · otal Thickness Measurement Inside of pipe...
Transcript of measurement capabilities and valuable options DMS 2 · otal Thickness Measurement Inside of pipe...
…to solve a wide range of corrosion/erosion applications
Stable high temperature measurement…
The DMS 2 in combination with the HT 400A dual-element probe and armor
jacketed cable provide stable measurement on equipment having surface
temperatures up to 1000ºF (538ºC). Single-element high-temperature delay
line probes are also compatible. Use of the MIN CAP mode in combination with
FREEZE enables high temperature readings and A-Scans to be obtained quickly
without lift-off effects from uncoupling.
4 ways to measure without removing expensive protective coatings for
maximum flexibility…TopCOAT, Dual-Multi, S-Peak and S-Flank modes for
measuring through coatings (paint) without including the coating layer in the
digital thickness reading. Measurements are made between two consecutive
backwall echoes in all modes (except TopCOAT) and low amplitude coating
layer echoes are ignored. (See back page for more information on TopCOAT.)
Test materials with external pitting…
Small footprint dual-element probes are used to gain access to the bottom of
surface pits to measure true minimum remaining wall thickness on corrosion
prone equipment (i.e. piping, pressure vessels, storage tanks, plates). Obtain
stable thickness measurements on small diameter piping and tubing. Measure
in areas of limited access.
Find and capture thinnest reading during corrosion/erosion surveys…
The MIN CAP (MINimum CAPture) measurement mode finds and captures the
minimum thickness reading in a sequence of measurements. Both the live and
currently captured minimum thickness readings are displayed simultaneously.
An adjustable “time-out” period (1 to 10 seconds) prevents a new min cap
sequence from starting prematurely upon intermittent uncoupling.
The DMS 2 works with DME, DM4 Family, and
DMS dual & single element probes for
maximum flexibility and applications versatility.
Paint Coating
Coating Measurement
Total Thickness Measurement
Inside of pipe(showing corrosion)
…with new powerful expandedmeasurement capabilities and valuable options
TopCOAT(Patent No. 6035717) is a
new thickness measurement
technique utilizing 2 channels (one
channel measures the coating
thickness and one measures the total
thickness) that works like this:
• Measures the coating thickness
• Calculates the necessary coating
layer correction
• Measures the total thickness of
the coating layer and metal layer
• Deducts the calculated coating
correction value
• Displays the correct (metal only)
thickness
Advantages of the TopCOATmeasurement technique….
1. Measure through coatings (paint)
without including the coating
layer in the digital thickness
reading. Thinner measure-
ments are also possible than
when using multiple echo
techniques.
2. Allows normal “high gain”
corrosion thickness measure-
ment with maximum sensitiv-
ity to pitting. Measurement is
made at high gain levels and
from the initial pulse to the 1st
backwall reflection which is
proven to be the most effec-
tive way to measure equipment
having irregular backwall reflect-
ing surfaces (i.e. eroded/corroded
piping, tanks, pressure vessels…).
3. Measure the thickness of the
coating (paint) layer itself.
4. If no coating is present, measure
the thickness of materials from
one side without knowing their
sound velocity.
The current velocity
of the material un-
der test is measured
and set into the
instrument. Thick-
ness measurements
are made without knowing the sound
velocity of the material. Thickness of
various materials can be measured
without recalibration.
B-Scan is a simple inspection method enabling the user to
scan a part or area and produce a cross-sectional view. No
probes switching, extra cables or fixtures needed; the DMS
2 B-Scan works with ANY TG Probe. Easy to use soft key
controls enable the user to quickly configure the B-Scan
parameters to produce the best graphical views possible.
The DMS 2 goes further and allows the user to save the B-
Scan within its internal memory (user can save up to 1,100
B-Scans) and later transfer the B-Scan to our UltraMATE™
software for storage to disk, analysis and printing.
Visit the NDT Super Site, AgfaNDT.com, for more information on Krautkramer’s DMS 2 and to learn more
about Agfa NDT’s complete line of ultrasonic, x-ray, digital and film systemsAgfaNDT.com
Agfa NDT Inc.50 Industrial Park Road
Lewistown, PA 17044
USA
Tel : (717)242-0327
Fax : 717/242-2606
E-mail: [email protected]
Agfa NDT GmbHRobert-Bosch-Str 3
D–50354 Huerth (Efferen)
Germany
Tel : +49-2233-6010
Fax : +49-2233-601402
E-mail: [email protected]
Agfa NDT Ltd.Millburn Hill Road
University of Warwick Science Park
Coventry, England CV4 7HS
United Kingdom
Tel : +44 0845 601 5771
Fax : +44 0845 130 5775
E-mail: [email protected]
Agfa NDT SA68, Chemin des Ormeaux
F–69760, Limonest
France
Tel : +33-472-179220
Fax : +33-478-475698
E-mail: [email protected]
DMS2/CT07025kPrinted In USA
Ultrasonic
Thickness Gague
DMS 2
DMS 2 is the “clear” choice…to satisfy your thickness measurement needs
Advanced ThicknessMeasurement
• No need to remove coatings
(paint) - measure through coatings
without including the coating layer
in the digital thickness reading
• Stable high-temperature measure-
ment up to 1000ºF with HT400A
probe and armor jacketed cable
• MIN CAP captures the minimum
thickness for a series of measure-
ments and displays the associated
A-Scan (32 Hz acquisition rate)
• DIALOG Intelligent Probes are
automatically recognized for opti-
mum instrument setup, perfor-
mance, and documentation
• Automatic probe zero corrects for
delay line dimensional changes
(wear & growth)
• 8 Hz selection updates the display
twice as fast as normal for imme-
diate response and enhances test
results when movement of the
probe is necessary vs. spot testing
• SIP mode utilizes single-element
probes for attenuative or thick
materials
• Gain is readily adjustable in 1 dB
steps via a direct access key
• Freeze locks the A-Scan display
for evaluation and verification of
the echoes; makes time base pa-
rameter adjustments easy
• 4 band passes automatically opti-
mize the receiver bandwidth to
match the frequency of the probe
for best results
• RF display provides additional
waveform information to assist
with difficult measurement appli-
cations (DMS 2 only)
B-Scan provides
a graphical cross-
sectional view of
the equipment
being inspected.
Very helpful in
quickly
identifying
laminated or thinned areas
Big Digits (.75” High) lets you take
measurements and see
results at a quick glance
Big Digits view is selectable with
either A-Scan (shown above) or data
file information displayed
A-Scan waveform for verification of
true remaining wall thickness and
better judgements on equipment
integrity
The DMS 2 has retained the user preferred features of its predecessor, the
popular DMS, and added expanded measurement capabilities to solve
remaining wall thickness applications. All information (large thickness
digits, A-Scan, B-Scan, and data files) is clearly displayed on a large high
resolution (1/4 VGA) LCD screen that is easily read in direct sunlight. The
DMS 2 is compact, easy-to-use, and like all Krautkramer D-Meters is
built-to-last in a custom molded, gasket sealed, high-impact resistant
housing with a rubber protective case to withstand use in harsh industrial
environments.
A-Scan, B-Scan or Big DIGITS…You decidewhat you want to see!
…for simple, reliable use under harsh field conditions
• Store/recall 20 parameter sets
for fast instrument setup and re-
peatable test results
• Lockable keypad prevents acci-
dental changes to operating pa-
rameters
Rugged, practical packaging…
• Custom molded, gasket-sealed,
high-impact resistant plastic
housing for dependable trouble-
free use
• Robust, rubber case for added pro-
tection in tough field environments
Easy to Use
• Direct access keys are at your
fingertips for immediate adjust-
ment of operating parameters
• Convenient color coded keypad
layout
• Frequent text messages guide
operation
• Compact, comfortable, one-hand
control (left or right hand)
• TEST key simulates a home key to
jump to test/measurement menu
• Dual/Dual-Multi hot key allows
for fast toggle between Dual and
Dual-Multi (thru-coat) modes
NeckStrap
HandStrap
…for powerful, flexible inspection data management
• Padded hand strap, neck strap,
waist belt, & prop-up stand are con-
venient features of the rubber case
• Full week’s work (40 hours) of
use on 4 standard AA alkaline
batteries - no special battery
packs or battery chargers needed
• I/O & AC power connectors
plugged by the rubber case to
prevent connector contamination
• 2 year warranty on parts & labor
• Store 150,000 readings/1100
A-Scans or B-Scans on-board
• 8 standard file structures includ-
ing compatibility with UltraPIPE
files to handle most inspection
routines
• Comprehensive D/R navigation
controls allow quick & easy move-
ment within a data file via 4 arrow
keys
• Append, insert & delete locations
to an existing data file
• Create Microgrids on the job to
collect from
4 to 81 (2x2
to 9x9
microgrid)
additional
readings at identified thinned lo-
cations per API-510 and API-653
• Temperature and memo input on
a per file basis
• Expanded Memory increases the
memory capacity of the onboard data
recorder to 318,000 thickness read-
ings/2,400 A-Scans or 2400 B-Scans.
• File status & file search to tag
and jump to critical locations for
quick review before leaving the
job site
• 32 character file names & 16-
character location names
• Save thickness readings and up
to 16 alphanumeric comments
with A-Scans, B-Scans, or
Microgrids per reading
• Last reading comparison on-site
of current vs. previous inspection
data on a per reading basis with
user set alarms for loss/growth
rates & changes
• Internet compatible upgrade soft-
ware allows instrument upgrade
directly from the internet… no
downtime or return of equipment
to factory required
• Easily interfaced to 3rd party data
management software programs
• A/C Power option for connection
to mains during stationary use.
Couple, read and record in
one step…with Remote SEND
Probes. Sealed membrane
send switch is built into the
probes
• Two large SEND keys eas-
ily accessed by left or right
thumb
• Alphanumeric key displays
the virtual keyboard to
easily enter alphanumeric
characters
BatteryCompartment
Field AccessoryBelt
Prop Stand
• Obstruct key
to easily mark
unreadable
locations
• NOTE key to
easily input
user defined
comments on
a per reading basis
• Direct bi-directional
communication with
UltraMATE® & UltraPIPE®
software programs for
straight-forward data
storage, analysis, &
management
DMS 2 is the “clear” choice…to satisfy your thickness measurement needs
Advanced ThicknessMeasurement
• No need to remove coatings
(paint) - measure through coatings
without including the coating layer
in the digital thickness reading
• Stable high-temperature measure-
ment up to 1000ºF with HT400A
probe and armor jacketed cable
• MIN CAP captures the minimum
thickness for a series of measure-
ments and displays the associated
A-Scan (32 Hz acquisition rate)
• DIALOG Intelligent Probes are
automatically recognized for opti-
mum instrument setup, perfor-
mance, and documentation
• Automatic probe zero corrects for
delay line dimensional changes
(wear & growth)
• 8 Hz selection updates the display
twice as fast as normal for imme-
diate response and enhances test
results when movement of the
probe is necessary vs. spot testing
• SIP mode utilizes single-element
probes for attenuative or thick
materials
• Gain is readily adjustable in 1 dB
steps via a direct access key
• Freeze locks the A-Scan display
for evaluation and verification of
the echoes; makes time base pa-
rameter adjustments easy
• 4 band passes automatically opti-
mize the receiver bandwidth to
match the frequency of the probe
for best results
• RF display provides additional
waveform information to assist
with difficult measurement appli-
cations (DMS 2 only)
B-Scan provides
a graphical cross-
sectional view of
the equipment
being inspected.
Very helpful in
quickly
identifying
laminated or thinned areas
Big Digits (.75” High) lets you take
measurements and see
results at a quick glance
Big Digits view is selectable with
either A-Scan (shown above) or data
file information displayed
A-Scan waveform for verification of
true remaining wall thickness and
better judgements on equipment
integrity
The DMS 2 has retained the user preferred features of its predecessor, the
popular DMS, and added expanded measurement capabilities to solve
remaining wall thickness applications. All information (large thickness
digits, A-Scan, B-Scan, and data files) is clearly displayed on a large high
resolution (1/4 VGA) LCD screen that is easily read in direct sunlight. The
DMS 2 is compact, easy-to-use, and like all Krautkramer D-Meters is
built-to-last in a custom molded, gasket sealed, high-impact resistant
housing with a rubber protective case to withstand use in harsh industrial
environments.
A-Scan, B-Scan or Big DIGITS…You decidewhat you want to see!
…for simple, reliable use under harsh field conditions
• Store/recall 20 parameter sets
for fast instrument setup and re-
peatable test results
• Lockable keypad prevents acci-
dental changes to operating pa-
rameters
Rugged, practical packaging…
• Custom molded, gasket-sealed,
high-impact resistant plastic
housing for dependable trouble-
free use
• Robust, rubber case for added pro-
tection in tough field environments
Easy to Use
• Direct access keys are at your
fingertips for immediate adjust-
ment of operating parameters
• Convenient color coded keypad
layout
• Frequent text messages guide
operation
• Compact, comfortable, one-hand
control (left or right hand)
• TEST key simulates a home key to
jump to test/measurement menu
• Dual/Dual-Multi hot key allows
for fast toggle between Dual and
Dual-Multi (thru-coat) modes
NeckStrap
HandStrap
…for powerful, flexible inspection data management
• Padded hand strap, neck strap,
waist belt, & prop-up stand are con-
venient features of the rubber case
• Full week’s work (40 hours) of
use on 4 standard AA alkaline
batteries - no special battery
packs or battery chargers needed
• I/O & AC power connectors
plugged by the rubber case to
prevent connector contamination
• 2 year warranty on parts & labor
• Store 150,000 readings/1100
A-Scans or B-Scans on-board
• 8 standard file structures includ-
ing compatibility with UltraPIPE
files to handle most inspection
routines
• Comprehensive D/R navigation
controls allow quick & easy move-
ment within a data file via 4 arrow
keys
• Append, insert & delete locations
to an existing data file
• Create Microgrids on the job to
collect from
4 to 81 (2x2
to 9x9
microgrid)
additional
readings at identified thinned lo-
cations per API-510 and API-653
• Temperature and memo input on
a per file basis
• Expanded Memory increases the
memory capacity of the onboard data
recorder to 318,000 thickness read-
ings/2,400 A-Scans or 2400 B-Scans.
• File status & file search to tag
and jump to critical locations for
quick review before leaving the
job site
• 32 character file names & 16-
character location names
• Save thickness readings and up
to 16 alphanumeric comments
with A-Scans, B-Scans, or
Microgrids per reading
• Last reading comparison on-site
of current vs. previous inspection
data on a per reading basis with
user set alarms for loss/growth
rates & changes
• Internet compatible upgrade soft-
ware allows instrument upgrade
directly from the internet… no
downtime or return of equipment
to factory required
• Easily interfaced to 3rd party data
management software programs
• A/C Power option for connection
to mains during stationary use.
Couple, read and record in
one step…with Remote SEND
Probes. Sealed membrane
send switch is built into the
probes
• Two large SEND keys eas-
ily accessed by left or right
thumb
• Alphanumeric key displays
the virtual keyboard to
easily enter alphanumeric
characters
BatteryCompartment
Field AccessoryBelt
Prop Stand
• Obstruct key
to easily mark
unreadable
locations
• NOTE key to
easily input
user defined
comments on
a per reading basis
• Direct bi-directional
communication with
UltraMATE® & UltraPIPE®
software programs for
straight-forward data
storage, analysis, &
management
DMS 2 is the “clear” choice…to satisfy your thickness measurement needs
Advanced ThicknessMeasurement
• No need to remove coatings
(paint) - measure through coatings
without including the coating layer
in the digital thickness reading
• Stable high-temperature measure-
ment up to 1000ºF with HT400A
probe and armor jacketed cable
• MIN CAP captures the minimum
thickness for a series of measure-
ments and displays the associated
A-Scan (32 Hz acquisition rate)
• DIALOG Intelligent Probes are
automatically recognized for opti-
mum instrument setup, perfor-
mance, and documentation
• Automatic probe zero corrects for
delay line dimensional changes
(wear & growth)
• 8 Hz selection updates the display
twice as fast as normal for imme-
diate response and enhances test
results when movement of the
probe is necessary vs. spot testing
• SIP mode utilizes single-element
probes for attenuative or thick
materials
• Gain is readily adjustable in 1 dB
steps via a direct access key
• Freeze locks the A-Scan display
for evaluation and verification of
the echoes; makes time base pa-
rameter adjustments easy
• 4 band passes automatically opti-
mize the receiver bandwidth to
match the frequency of the probe
for best results
• RF display provides additional
waveform information to assist
with difficult measurement appli-
cations (DMS 2 only)
B-Scan provides
a graphical cross-
sectional view of
the equipment
being inspected.
Very helpful in
quickly
identifying
laminated or thinned areas
Big Digits (.75” High) lets you take
measurements and see
results at a quick glance
Big Digits view is selectable with
either A-Scan (shown above) or data
file information displayed
A-Scan waveform for verification of
true remaining wall thickness and
better judgements on equipment
integrity
The DMS 2 has retained the user preferred features of its predecessor, the
popular DMS, and added expanded measurement capabilities to solve
remaining wall thickness applications. All information (large thickness
digits, A-Scan, B-Scan, and data files) is clearly displayed on a large high
resolution (1/4 VGA) LCD screen that is easily read in direct sunlight. The
DMS 2 is compact, easy-to-use, and like all Krautkramer D-Meters is
built-to-last in a custom molded, gasket sealed, high-impact resistant
housing with a rubber protective case to withstand use in harsh industrial
environments.
A-Scan, B-Scan or Big DIGITS…You decidewhat you want to see!
…for simple, reliable use under harsh field conditions
• Store/recall 20 parameter sets
for fast instrument setup and re-
peatable test results
• Lockable keypad prevents acci-
dental changes to operating pa-
rameters
Rugged, practical packaging…
• Custom molded, gasket-sealed,
high-impact resistant plastic
housing for dependable trouble-
free use
• Robust, rubber case for added pro-
tection in tough field environments
Easy to Use
• Direct access keys are at your
fingertips for immediate adjust-
ment of operating parameters
• Convenient color coded keypad
layout
• Frequent text messages guide
operation
• Compact, comfortable, one-hand
control (left or right hand)
• TEST key simulates a home key to
jump to test/measurement menu
• Dual/Dual-Multi hot key allows
for fast toggle between Dual and
Dual-Multi (thru-coat) modes
NeckStrap
HandStrap
…for powerful, flexible inspection data management
• Padded hand strap, neck strap,
waist belt, & prop-up stand are con-
venient features of the rubber case
• Full week’s work (40 hours) of
use on 4 standard AA alkaline
batteries - no special battery
packs or battery chargers needed
• I/O & AC power connectors
plugged by the rubber case to
prevent connector contamination
• 2 year warranty on parts & labor
• Store 150,000 readings/1100
A-Scans or B-Scans on-board
• 8 standard file structures includ-
ing compatibility with UltraPIPE
files to handle most inspection
routines
• Comprehensive D/R navigation
controls allow quick & easy move-
ment within a data file via 4 arrow
keys
• Append, insert & delete locations
to an existing data file
• Create Microgrids on the job to
collect from
4 to 81 (2x2
to 9x9
microgrid)
additional
readings at identified thinned lo-
cations per API-510 and API-653
• Temperature and memo input on
a per file basis
• Expanded Memory increases the
memory capacity of the onboard data
recorder to 318,000 thickness read-
ings/2,400 A-Scans or 2400 B-Scans.
• File status & file search to tag
and jump to critical locations for
quick review before leaving the
job site
• 32 character file names & 16-
character location names
• Save thickness readings and up
to 16 alphanumeric comments
with A-Scans, B-Scans, or
Microgrids per reading
• Last reading comparison on-site
of current vs. previous inspection
data on a per reading basis with
user set alarms for loss/growth
rates & changes
• Internet compatible upgrade soft-
ware allows instrument upgrade
directly from the internet… no
downtime or return of equipment
to factory required
• Easily interfaced to 3rd party data
management software programs
• A/C Power option for connection
to mains during stationary use.
Couple, read and record in
one step…with Remote SEND
Probes. Sealed membrane
send switch is built into the
probes
• Two large SEND keys eas-
ily accessed by left or right
thumb
• Alphanumeric key displays
the virtual keyboard to
easily enter alphanumeric
characters
BatteryCompartment
Field AccessoryBelt
Prop Stand
• Obstruct key
to easily mark
unreadable
locations
• NOTE key to
easily input
user defined
comments on
a per reading basis
• Direct bi-directional
communication with
UltraMATE® & UltraPIPE®
software programs for
straight-forward data
storage, analysis, &
management
…to solve a wide range of corrosion/erosion applications
Stable high temperature measurement…
The DMS 2 in combination with the HT 400A dual-element probe and armor
jacketed cable provide stable measurement on equipment having surface
temperatures up to 1000ºF (538ºC). Single-element high-temperature delay
line probes are also compatible. Use of the MIN CAP mode in combination with
FREEZE enables high temperature readings and A-Scans to be obtained quickly
without lift-off effects from uncoupling.
4 ways to measure without removing expensive protective coatings for
maximum flexibility…TopCOAT, Dual-Multi, S-Peak and S-Flank modes for
measuring through coatings (paint) without including the coating layer in the
digital thickness reading. Measurements are made between two consecutive
backwall echoes in all modes (except TopCOAT) and low amplitude coating
layer echoes are ignored. (See back page for more information on TopCOAT.)
Test materials with external pitting…
Small footprint dual-element probes are used to gain access to the bottom of
surface pits to measure true minimum remaining wall thickness on corrosion
prone equipment (i.e. piping, pressure vessels, storage tanks, plates). Obtain
stable thickness measurements on small diameter piping and tubing. Measure
in areas of limited access.
Find and capture thinnest reading during corrosion/erosion surveys…
The MIN CAP (MINimum CAPture) measurement mode finds and captures the
minimum thickness reading in a sequence of measurements. Both the live and
currently captured minimum thickness readings are displayed simultaneously.
An adjustable “time-out” period (1 to 10 seconds) prevents a new min cap
sequence from starting prematurely upon intermittent uncoupling.
The DMS 2 works with DME, DM4 Family, and
DMS dual & single element probes for
maximum flexibility and applications versatility.
Paint Coating
Coating Measurement
Total Thickness Measurement
Inside of pipe(showing corrosion)
…with new powerful expandedmeasurement capabilities and valuable options
TopCOAT(Patent No. 6035717) is a
new thickness measurement
technique utilizing 2 channels (one
channel measures the coating
thickness and one measures the total
thickness) that works like this:
• Measures the coating thickness
• Calculates the necessary coating
layer correction
• Measures the total thickness of
the coating layer and metal layer
• Deducts the calculated coating
correction value
• Displays the correct (metal only)
thickness
Advantages of the TopCOATmeasurement technique….
1. Measure through coatings (paint)
without including the coating
layer in the digital thickness
reading. Thinner measure-
ments are also possible than
when using multiple echo
techniques.
2. Allows normal “high gain”
corrosion thickness measure-
ment with maximum sensitiv-
ity to pitting. Measurement is
made at high gain levels and
from the initial pulse to the 1st
backwall reflection which is
proven to be the most effec-
tive way to measure equipment
having irregular backwall reflect-
ing surfaces (i.e. eroded/corroded
piping, tanks, pressure vessels…).
3. Measure the thickness of the
coating (paint) layer itself.
4. If no coating is present, measure
the thickness of materials from
one side without knowing their
sound velocity.
The current velocity
of the material un-
der test is measured
and set into the
instrument. Thick-
ness measurements
are made without knowing the sound
velocity of the material. Thickness of
various materials can be measured
without recalibration.
B-Scan is a simple inspection method enabling the user to
scan a part or area and produce a cross-sectional view. No
probes switching, extra cables or fixtures needed; the DMS
2 B-Scan works with ANY TG Probe. Easy to use soft key
controls enable the user to quickly configure the B-Scan
parameters to produce the best graphical views possible.
The DMS 2 goes further and allows the user to save the B-
Scan within its internal memory (user can save up to 1,100
B-Scans) and later transfer the B-Scan to our UltraMATE™
software for storage to disk, analysis and printing.
Visit the NDT Super Site, AgfaNDT.com, for more information on Krautkramer’s DMS 2 and to learn more
about Agfa NDT’s complete line of ultrasonic, x-ray, digital and film systemsAgfaNDT.com
Agfa NDT Inc.50 Industrial Park Road
Lewistown, PA 17044
USA
Tel : (717)242-0327
Fax : 717/242-2606
E-mail: [email protected]
Agfa NDT GmbHRobert-Bosch-Str 3
D–50354 Huerth (Efferen)
Germany
Tel : +49-2233-6010
Fax : +49-2233-601402
E-mail: [email protected]
Agfa NDT Ltd.Millburn Hill Road
University of Warwick Science Park
Coventry, England CV4 7HS
United Kingdom
Tel : +44 0845 601 5771
Fax : +44 0845 130 5775
E-mail: [email protected]
Agfa NDT SA68, Chemin des Ormeaux
F–69760, Limonest
France
Tel : +33-472-179220
Fax : +33-478-475698
E-mail: [email protected]
DMS2/CT07025kPrinted In USA
Ultrasonic
Thickness Gague
DMS 2
…to solve a wide range of corrosion/erosion applications
Stable high temperature measurement…
The DMS 2 in combination with the HT 400A dual-element probe and armor
jacketed cable provide stable measurement on equipment having surface
temperatures up to 1000ºF (538ºC). Single-element high-temperature delay
line probes are also compatible. Use of the MIN CAP mode in combination with
FREEZE enables high temperature readings and A-Scans to be obtained quickly
without lift-off effects from uncoupling.
4 ways to measure without removing expensive protective coatings for
maximum flexibility…TopCOAT, Dual-Multi, S-Peak and S-Flank modes for
measuring through coatings (paint) without including the coating layer in the
digital thickness reading. Measurements are made between two consecutive
backwall echoes in all modes (except TopCOAT) and low amplitude coating
layer echoes are ignored. (See back page for more information on TopCOAT.)
Test materials with external pitting…
Small footprint dual-element probes are used to gain access to the bottom of
surface pits to measure true minimum remaining wall thickness on corrosion
prone equipment (i.e. piping, pressure vessels, storage tanks, plates). Obtain
stable thickness measurements on small diameter piping and tubing. Measure
in areas of limited access.
Find and capture thinnest reading during corrosion/erosion surveys…
The MIN CAP (MINimum CAPture) measurement mode finds and captures the
minimum thickness reading in a sequence of measurements. Both the live and
currently captured minimum thickness readings are displayed simultaneously.
An adjustable “time-out” period (1 to 10 seconds) prevents a new min cap
sequence from starting prematurely upon intermittent uncoupling.
The DMS 2 works with DME, DM4 Family, and
DMS dual & single element probes for
maximum flexibility and applications versatility.
Paint Coating
Coating Measurement
Total Thickness Measurement
Inside of pipe(showing corrosion)
…with new powerful expandedmeasurement capabilities and valuable options
TopCOAT(Patent No. 6035717) is a
new thickness measurement
technique utilizing 2 channels (one
channel measures the coating
thickness and one measures the total
thickness) that works like this:
• Measures the coating thickness
• Calculates the necessary coating
layer correction
• Measures the total thickness of
the coating layer and metal layer
• Deducts the calculated coating
correction value
• Displays the correct (metal only)
thickness
Advantages of the TopCOATmeasurement technique….
1. Measure through coatings (paint)
without including the coating
layer in the digital thickness
reading. Thinner measure-
ments are also possible than
when using multiple echo
techniques.
2. Allows normal “high gain”
corrosion thickness measure-
ment with maximum sensitiv-
ity to pitting. Measurement is
made at high gain levels and
from the initial pulse to the 1st
backwall reflection which is
proven to be the most effec-
tive way to measure equipment
having irregular backwall reflect-
ing surfaces (i.e. eroded/corroded
piping, tanks, pressure vessels…).
3. Measure the thickness of the
coating (paint) layer itself.
4. If no coating is present, measure
the thickness of materials from
one side without knowing their
sound velocity.
The current velocity
of the material un-
der test is measured
and set into the
instrument. Thick-
ness measurements
are made without knowing the sound
velocity of the material. Thickness of
various materials can be measured
without recalibration.
B-Scan is a simple inspection method enabling the user to
scan a part or area and produce a cross-sectional view. No
probes switching, extra cables or fixtures needed; the DMS
2 B-Scan works with ANY TG Probe. Easy to use soft key
controls enable the user to quickly configure the B-Scan
parameters to produce the best graphical views possible.
The DMS 2 goes further and allows the user to save the B-
Scan within its internal memory (user can save up to 1,100
B-Scans) and later transfer the B-Scan to our UltraMATE™
software for storage to disk, analysis and printing.
Visit the NDT Super Site, AgfaNDT.com, for more information on Krautkramer’s DMS 2 and to learn more
about Agfa NDT’s complete line of ultrasonic, x-ray, digital and film systemsAgfaNDT.com
Agfa NDT Inc.50 Industrial Park Road
Lewistown, PA 17044
USA
Tel : (717)242-0327
Fax : 717/242-2606
E-mail: [email protected]
Agfa NDT GmbHRobert-Bosch-Str 3
D–50354 Huerth (Efferen)
Germany
Tel : +49-2233-6010
Fax : +49-2233-601402
E-mail: [email protected]
Agfa NDT Ltd.Millburn Hill Road
University of Warwick Science Park
Coventry, England CV4 7HS
United Kingdom
Tel : +44 0845 601 5771
Fax : +44 0845 130 5775
E-mail: [email protected]
Agfa NDT SA68, Chemin des Ormeaux
F–69760, Limonest
France
Tel : +33-472-179220
Fax : +33-478-475698
E-mail: [email protected]
DMS2/CT07025kPrinted In USA
Ultrasonic
Thickness Gague
DMS 2