Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped...

16
Measurement and Control of Microphonics for RIA Terry L. Grimm Michigan State University March 2005

Transcript of Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped...

Page 1: Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped 3180704-003 6.5 Hz helium oscillation 57 Hz electric motor. Summary • Microphonics

Measurement and Control of Microphonics for RIA

Terry L. GrimmMichigan State University

March 2005

Page 2: Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped 3180704-003 6.5 Hz helium oscillation 57 Hz electric motor. Summary • Microphonics

Outline

• SRF for the Rare Isotope Accelerator (RIA)Cryomodule and cavity designFrequency tuner

• Beam loading & rf requirements• Microphonics

Vibration SourcesCryomodule and cavity design issuesMethods of controlMeasurementAdaptive feedforward cancellation

• Summary

Page 3: Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped 3180704-003 6.5 Hz helium oscillation 57 Hz electric motor. Summary • Microphonics

Prototype 805 MHz β=0.47 Cryomodule

Page 4: Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped 3180704-003 6.5 Hz helium oscillation 57 Hz electric motor. Summary • Microphonics

β=0.47 Tuner-Cavity-Power Coupler

He Vessel

PowerCoupler

Tuner

Page 5: Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped 3180704-003 6.5 Hz helium oscillation 57 Hz electric motor. Summary • Microphonics

External/room temperature tuner

−6 −4 −2 0 2 4 6−600

−400

−200

0

200

400

600

Displacemant (mm)

∆ F

requ

ncy

(kH

z)

Coarse Tuner Exercizes on Cavity #2 at 4.22K

f0 = 805.585 MHz

Expanding CavityCompressing Cavity

0 20 40 60 80 1000

2

4

6

8

10

12

Voltage (V)

∆ F

requ

ncy

(kH

z)

Piezo Tuner Measurements on Cavity #2 at 4.20K

f0 = 805.554 MHz

First CycleSecond Cycle

Fine tuner ~ 10 kHz90 µm piezoelectric (PI)

Coarse tuner ~ 1 MHz

Page 6: Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped 3180704-003 6.5 Hz helium oscillation 57 Hz electric motor. Summary • Microphonics

Beam loading & rf requirements

• Design beam for RIA driver linac– cw (no dynamic Lorentz detuning)– 400 kW, 400 MeV/u 238U88,89,90+

– 0.37 mA

• Experience– S-DALINAC, QL~ 3x107

– CEBAF Upgrade, QL ~ low 107

Type 6-cell 6-cell 6-cell βg 0.47 0.61 0.81

Va(MV) 5.12 8.17 13.46 Pbeam(W) 1660 2640 2600*

Qbeam 9.1x107 9.1x107 1.4x108 Pg(W) 3320 5280 5200

QL 3.0x107 3.0x107 4.7x107 Control bandwidth

∆allowed(Hz) 25 25 16

*Decreased from Maximum value due to transit time

factor

Page 7: Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped 3180704-003 6.5 Hz helium oscillation 57 Hz electric motor. Summary • Microphonics

Microphonics – Vibration Sources

• Pumps/rotating machinery– Sinusoidal disturbances at harmonics of revolution

frequency• cw/pulsed operation

– For pulsed operation dynamic Lorentz detuning will dominate

• Helium oscillations– 2 K superfluid (no boiling and less pressure

fluctuations compared to 4 K)– Cryoplant– Thermo-acoustic oscillations

• White/broadband noise

Page 8: Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped 3180704-003 6.5 Hz helium oscillation 57 Hz electric motor. Summary • Microphonics

Microphonics – Cryomodule Design

• Cavity design– Stiffen– Compensation (cancel E & B-field detuning)

• Mechanical resonances– Eliminate and shift to high frequency (>200 Hz)

• Isolation– Ground, piping, waveguides, pumps– Inertia

Page 9: Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped 3180704-003 6.5 Hz helium oscillation 57 Hz electric motor. Summary • Microphonics

Microphonics – Methods of Control [1]

• Passive and active damping– Sources– Transmission (pipes, ground, waveguide)

• Passive damping of the cavity– Friction (QWR, Facco)

• Lorentz force– Small change in cavity amplitude (Delayen)

• Reactive element– Use input or dedicated coupler– VCX (Shepard), Copper cavities (CERN PS)

• RF phase drift – fvib >> ∆fRF, use vector-sum control

Page 10: Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped 3180704-003 6.5 Hz helium oscillation 57 Hz electric motor. Summary • Microphonics

Microphonics – Methods of Control [2]

• Fast mechanical tuner– Piezoelectric, magnetostrictive, electromagnet, etc.

• Cryomodule & cavity– Feedforward/feedback

• Many algorithms and techniques

• Anticipated vibration spectrum– Dominated by sinusoidal disturbances

• 60 Hz asynchronous motors, etc.– Vibration frequencies less than 200 Hz

• Higher depending on cavity isolation and resonances

Page 11: Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped 3180704-003 6.5 Hz helium oscillation 57 Hz electric motor. Summary • Microphonics

Cavity and microphonics circuit

Qext, fixed ≅ 1x107

Qext, transformer ≅ 105 to 4x109

Page 12: Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped 3180704-003 6.5 Hz helium oscillation 57 Hz electric motor. Summary • Microphonics

Measured microphonics

• Measured vibration spectrum– Primarily discrete Fourier components

• Less than 40 Hz pk-pk RF frequency shift• Modulation frequencies less than 80 Hz• Main components 59.5 & 59.7 Hz

– Identified using accelerometer as cryoplant screw compressors

• Additional components near 54 Hz– Likely a motor and mechanical resonance

Page 13: Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped 3180704-003 6.5 Hz helium oscillation 57 Hz electric motor. Summary • Microphonics

Adaptive Feedforward Cancelation

• Individual sinusoidal disturbances are damped– Unlimited number of Fourier components

• Generates a control signal– Needs disturbance frequency and rudimentary

cavity response (no analytic transfer function)

Page 14: Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped 3180704-003 6.5 Hz helium oscillation 57 Hz electric motor. Summary • Microphonics

Tuner Bode diagram

0 10 20 30 40 50 60 70 80 90 1000

0.02

0.04

0.06

0.08

0.1

Frequency (Hz)

Mag

nitu

de

0 10 20 30 40 50 60 70 80 90 100-180-135

-90-45

04590

135180

Frequency (Hz)

Phas

e (d

egre

es)

Page 15: Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped 3180704-003 6.5 Hz helium oscillation 57 Hz electric motor. Summary • Microphonics

Active damping

• Adaptive feedforward cancellation of sinusoidal disturbances

30 40 50 60 70 80Disturbance Frequency (Hz)

8060

4020

0

Peak

-to-p

eak

Cav

ity D

etun

e (H

z)

no dampingdamping

3180704-001

0 20 40 60 80Disturbance Frequency (Hz)

120

8040

0

Peak

-to-p

eak

Cav

ity D

etun

e (H

z)

undampeddamped

3180704-003

6.5 Hz helium oscillation 57 Hz electric motor

Page 16: Measurement and Control of Microphonics for RIAPeak-to-peak Cavity Detune (Hz) undamped damped 3180704-003 6.5 Hz helium oscillation 57 Hz electric motor. Summary • Microphonics

Summary

• Microphonics dominated by low frequency sinusoidal disturbances from rotating machinery (cw operation)

• Many techniques to damp or alleviate microphonics– Source– Transmission– Design of cryomodule and cavity– Passive and active damping

• Demonstrated Adaptive Feedforward Cancellation for RIA

• CW operation with loaded-Q in the mid-107 range (and likely higher) appears feasible