MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and...

30
CHAPTER Send documentation comments to [email protected] 4-1 Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide OL-25752-02 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) This chapter describes how to set up a basic core-edge topology with an MDS 9000 switch configured for interop mode 1 at the core, and two Brocade switches and one McData switch at the edge. All devices are connected to the edge switches. However, all traffic must flow through the core switch to reach its destination. This chapter includes the following sections: Specifications, page 4-1 Expected Topology Behavior, page 4-2 Configuration, page 4-4 Verification, page 4-7 Zoning, page 4-25 Specifications The following switches and code levels were used for this example configuration: MDS 9513 running NX-OS Release 5.2(1) Brocade 4900 Version 6.4.1a Brocade 5100 Version 6.3.2a McData 4500 version 09.09.09 2 The example configuration uses MDS 9509 switches in the core, and Brocade 5100, Brocade 4900, and McData 4500 switches on the edge. Figure 4-1 shows the topology used for this example configuration.

Transcript of MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and...

Page 1: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Cisco MDS 9000 Family SwOL-25752-02

C H A P T E R 4

MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1)

This chapter describes how to set up a basic core-edge topology with an MDS 9000 switch configured for interop mode 1 at the core, and two Brocade switches and one McData switch at the edge. All devices are connected to the edge switches. However, all traffic must flow through the core switch to reach its destination.

This chapter includes the following sections:

• Specifications, page 4-1

• Expected Topology Behavior, page 4-2

• Configuration, page 4-4

• Verification, page 4-7

• Zoning, page 4-25

SpecificationsThe following switches and code levels were used for this example configuration:

• MDS 9513 running NX-OS Release 5.2(1)

• Brocade 4900 Version 6.4.1a

• Brocade 5100 Version 6.3.2a

• McData 4500 version 09.09.09 2

The example configuration uses MDS 9509 switches in the core, and Brocade 5100, Brocade 4900, and McData 4500 switches on the edge.

Figure 4-1 shows the topology used for this example configuration.

4-1itch-to-Switch Interoperability Configuration Guide

Page 2: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Expected Topology Behavior

Figure 4-1 Dual MDS 9509 Switch Core with Brocade and McData Switch Edge Topology

Expected Topology BehaviorThis section covers the Fibre Channel services and features that act differently in this topology (Figure 4-1) as compared to a homogeneous, single-vendor implementation.

This section includes the following topics:

• Zoning, page 4-3

• FSPF, page 4-3

• Trunking and PortChannels, page 4-3

• Domain IDs, page 4-3

VZ1

Target 1 Host 1

VZ3

Target 3 Host 3

VZ2

Target 2 Host 2

Brocade 4900 McData 450061 (97)

Brocade 51007f (127)

66 (102)21

8 10 16 11 10

17

21

20

29

25

2G 2G

23

1/1 3/1

3/5

3/25

64 (100) 62 (98)

1/5

1/252 Gigabit ISL

3305

93

Unless noted, all ISL linksare 4 Gigabit

MDS 9513 MDS 9509

4-2Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 3: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Expected Topology Behavior

ZoningAll zone members will be pWWNs in the core-edge topology because the Brocade domain/port nomenclature is not a valid form (per the FC standard), and the McData switch only supports zone members based upon pWWNs. When a zone set (or configuration, in Brocade terminology) activation is made at the core, the zone set activation reaches all switches at the same time because all the switches are one hop away (except for the other core switch, which is two hops away).

The edge switches provide all of the zone security, because the MDS 9000 switch does not check the source or destination of the frame when traversing E ports. Brocade switches only check the zoning information on the egress port of the fabric.

Note After two active zone sets successfully merge, always copy the active zone set to the full zone set database prior to modifying it on the MDS 9000 switch.

FSPFAll links within the topology appear with the link cost of 250, except for the two paths leading to the Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500.

The Brocade switches load balance their routes using source and destination; the ingress edge switch uses the same core switch for all traffic that has the same source and destination pair. If the Brocade switch could load balance using source/destination/ox-id, then it could choose either of the two core switches for the route through the fabric. The two-level core does not allow the MDS 9000 switch, which can load balance using source/destination/ox-id, to load balance across multiple edge switches.

Trunking and PortChannelsThe lack of MDS 9000 switch-to-MDS 9000-switch connections prohibits the topology from containing TE ports or PortChannels. While in interop mode, the Brocade switches do not support trunked ports of any type. Only standard E ports are used for the ISLs.

Domain IDsThe domain IDs are limited to the 97 to 127 range due to a restriction imposed by McData's inability to handle IDs outside of that range. While Brocade switches and MDS 9000 switches can handle domain IDs outside of this range, their implementation of interoperability mode includes this limitation.

Domain ID modifications can be handled in two ways, disruptively or nondisruptively:

• Disruptive—This event impacts the entire switch. When changing domain IDs, Brocade and McData both require the entire switch to be taken offline and/or rebooted.

• Nondisruptive—This event is limited to the VSAN where the event is taking place. Only the MDS 9000 switch can perform this action, as the domain manager process for this VSAN is restarted and not the entire switch. This requires any device logged into the VSAN to log into the fabric again to obtain a new FC ID.

4-3Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 4: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Configuration

ConfigurationThis section describes the configuration process and includes the following topics:

• Configuring the McData 4500 Switch, page 4-4

• Configuring the MDS 9000 Switch and the Brocade Switches, page 4-7

Configuring the McData 4500 SwitchIn this example, the McData 4500 switch is configured for interop mode using Telnet and the CLI. The switch is placed in an offline state, the default zone is set to deny, the domain ID is set, and timers are altered to match the fabric.

To configure the McData 4500 switch, follow these steps:

Step 1 Display current switch information.

Root> show switchRoot> show switchState: OnlineR_A_TOV: 100E_D_TOV: 20Preferred Domain ID: 1Domain ID Offset: 96Switch Priority: Never PrincipalRerouting Delay: DisabledInterop Mode: McDATA Fabric 1.0Active Domain ID: 1World Wide Name: 10:00:08:00:88:60:30:54Insistent Domain ID: DisabledDomain RSCN: EnabledZoning RSCN: EnabledFC Address Domain: 61 (hex)Limited Fabric RSCN: DisabledZone FlexPars: Fabric FilteringRSCN Zone Isolation: Fabric FilteringSafe Zoning: DisabledISL FSPF Cost: Ignore Port SpeedWeb Enabled: EnabledFrame Resize State: EnabledBlock Dup WWN State: DisabledAPI Enabled: EnabledAPI Management IP: 172.25.242.37Password Exp. Time: 0

Step 2 Alter the timers, RA_TOV and ED_TOV, if needed. These options are listed in the config switch menu.

Root> config switchConfig.Switch>.. - Move back one levelFrameResizeState - Set the FRAME_RESIZE enabled stateRSCNZoneIsolation - Set the RSCN Zone Isolation stateapiState - Set the api enabled statebanner - Configure the bannerblockDupWWN - Set Block duplicate WWN statecommadelim - Toggle comma-delimited display modedomainIDOffset - Set the domain ID offset for the switchdomainRSCN - Set the switch state for generation of domain RSCN'sedTOV - Set the E_D_TOV for the switch

4-4Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 5: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Configuration

insistDomainId - Set the Insistent domain ID state for the switchinteropMode - Set the Interoperability mode for the switchislFSPFCost - Sets the FSPF cost of ISLslogin - Login to CLI under different access rightslogout - Logout of CLIltdFabRSCN - Set the switch state for limiting Fabric RSCN'sprefDomainId - Set the preferred domain ID for the switchpriority - Set the switch priorityraTOV - Set the R_A_TOV for the switchrerouteDelay - Enable or disable the reroute delayroot - Move back to root level

Step 3 Set the switch offline. The switch must be offline before changing the mode to interop.

Config.Switch> interopmode openError 045: Not Allowed While Switch Online

Root> maint systemMaint.System> setOnlineState 0Maint.System> root

Root> show switchState: Offline <=== OfflineR_A_TOV: 100E_D_TOV: 20Preferred Domain ID: 1Domain ID Offset: 96Switch Priority: Never PrincipalRerouting Delay: DisabledInterop Mode: McDATA Fabric 1.0 <=== McData native modeActive Domain ID: 1World Wide Name: 10:00:08:00:88:60:30:54Insistent Domain ID: DisabledDomain RSCN: EnabledZoning RSCN: EnabledFC Address Domain: 61 (hex)Limited Fabric RSCN: DisabledZone FlexPars: Fabric FilteringRSCN Zone Isolation: Fabric FilteringSafe Zoning: DisabledISL FSPF Cost: Ignore Port SpeedWeb Enabled: EnabledFrame Resize State: EnabledBlock Dup WWN State: DisabledAPI Enabled: EnabledAPI Management IP: 172.25.242.37Password Exp. Time: 0

Step 4 Set the mode to interop.

Root> config switchConfig.Switch> interopmode openWarning: Zone members configured by domain and port will be ignored.

Config.Switch> rootRoot> config zoningConfig.Zoning> setDefZoneState 0Config.Zoning> root

Root> show switchState: Offline <=== offlineR_A_TOV: 100E_D_TOV: 20Preferred Domain ID: 1

4-5Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 6: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Configuration

Domain ID Offset: 96Switch Priority: Never PrincipalRerouting Delay: DisabledInterop Mode: Open Fabric 1.0 <=== InterOp modeActive Domain ID: 1World Wide Name: 10:00:08:00:88:60:30:54Insistent Domain ID: DisabledDomain RSCN: EnabledZoning RSCN: EnabledFC Address Domain: 61 (hex)Limited Fabric RSCN: DisabledZone FlexPars: Fabric FilteringRSCN Zone Isolation: Fabric FilteringSafe Zoning: DisabledISL FSPF Cost: Ignore Port SpeedWeb Enabled: EnabledFrame Resize State: EnabledBlock Dup WWN State: DisabledAPI Enabled: EnabledError 81: Default Zone Enabled

Step 5 Set the preferred domain ID, with an offset of 0x60. In this example, the McData switch is domain ID 0x61 (97). The FC_IDs for nodes on this switch are 61xxxx.

Root> config switchConfig.Switch> prefDomainId 1

Config.Switch> ..Config> ..Root> maintMaint> systemMaint.System> setonlinestate 1Maint.System> ..Maint> ..

Root> show switchState: Online <=== OnlineR_A_TOV: 100E_D_TOV: 20Preferred Domain ID: 1Domain ID Offset: 96Switch Priority: Never PrincipalRerouting Delay: DisabledInterop Mode: Open Fabric 1.0 <=== Interop modeActive Domain ID: 0World Wide Name: 10:00:08:00:88:60:30:54Insistent Domain ID: DisabledDomain RSCN: EnabledZoning RSCN: EnabledFC Address Domain: 60 (hex)Limited Fabric RSCN: DisabledZone FlexPars: Fabric FilteringRSCN Zone Isolation: Fabric FilteringSafe Zoning: DisabledISL FSPF Cost: Ignore Port SpeedWeb Enabled: EnabledFrame Resize State: EnabledBlock Dup WWN State: DisabledAPI Enabled: Enabled

4-6Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 7: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

Configuring the MDS 9000 Switch and the Brocade SwitchesSee Chapter 3, “MDS 9000 Core with Brocade Edge Topology (Interop Mode 1),” for examples of how to set the MDS 9000 switch and Brocade switches to interop mode.

VerificationThis section highlights the commands used to verify that the fabric is up and running in interoperability mode. It includes the following topics:

• Verifying the MDS 9513 Switch, page 4-7

• Verifying the Brocade 4900 Switch, page 4-11

• Verifying the Brocade 5100 Switch, page 4-18

• Verifying the McData 4500 Switch, page 4-22

Verifying the MDS 9513 SwitchThe following examples show the commands used to verify the configuration of the first MDS 9513 switch (see Figure 4-1):

MDS9513# show verSoftware BIOS: version 1.0.10 loader: version N/A kickstart: version 5.2(1) system: version 5.2(1) BIOS compile time: 01/08/09 kickstart image file is: bootflash:///m9500-sf2ek9-kickstart-mz.5.2.1.bin.S74 kickstart compile time: 12/25/2020 12:00:00 [07/16/2011 22:48:52] system image file is: bootflash:///m9500-sf2ek9-mz.5.2.1.bin.S74 system compile time: 6/7/2011 13:00:00 [07/17/2011 00:15:24]

Hardware cisco MDS 9513 (13 Slot) Chassis ("Supervisor/Fabric-2a") Motorola, 7447A, altivec with 2071296 kB of memory. Processor Board ID JAE141501UD

Device name: MDS9513 bootflash: 1000440 kB slot0: 0 kB (expansion flash) MDS9513# show int brief -------------------------------------------------------------------------------Interface Vsan Admin Admin Status SFP Oper Oper Port Mode Trunk Mode Speed Channel Mode (Gbps)-------------------------------------------------------------------------------fc1/1 1 auto on up swl E 4 --fc1/2 1 FX on down swl -- --fc1/3 1 FX on down swl -- --fc1/4 1 FX on sfpAbsent -- -- --fc1/5 1 auto on up swl E 2 --fc1/6 1 FX on sfpAbsent -- -- --fc1/7 1 FX on down swl -- --

4-7Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 8: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

fc1/13 1 auto on down swl -- --fc1/14 1 FX on down swl -- --fc1/15 1 FX on down swl -- --fc1/21 1 FX on down swl -- --fc1/22 1 FX on sfpAbsent -- -- --fc1/23 1 FX on down swl -- --fc1/24 1 FX on sfpAbsent -- -- --fc1/25 1 auto on up swl E 4 --fc1/26 1 FX on down swl -- --fc1/27 1 FX on down swl

MDS9513# sh vsan 1vsan 1 information name:VSAN0001 state:active interoperability mode:1 loadbalancing:src-id/dst-id/oxid operational state:up

MDS9513# sh fcdomain vsan 1The local switch is a Subordinated Switch. Local switch run time information: State: Stable Local switch WWN: 20:01:00:05:9b:01:b4:b3 Running fabric name: 20:01:00:05:9b:00:11:5f Running priority: 128 Current domain ID: 0x64(100)

Local switch configuration information: State: Enabled FCID persistence: Enabled Auto-reconfiguration: Disabled Contiguous-allocation: Disabled Configured fabric name: 20:01:00:05:30:00:28:df Optimize Mode: Disabled Configured priority: 128 Configured domain ID: 0x64(100) (preferred)

Principal switch run time information: Running priority: 2

Interface Role RCF-reject---------------- ------------- ------------fc1/1 Upstream Disabledfc1/5 Downstream Disabledfc1/25 Non-principal Disabled---------------- ------------- ------------

MDS9513# sh fcdomain domain-list vsan 1

Number of domains: 5Domain ID WWN--------- ----------------------- 0x61(97) 10:00:08:00:88:60:30:54 0x62(98) 20:01:00:05:9b:00:11:5f [Principal]0x64(100) 20:01:00:05:9b:01:b4:b3 [Local]0x66(102) 10:00:00:05:1e:03:ae:560x7f(127) 10:00:00:05:1e:c4:3f:63

MDS9513# sh fspf internal route vsan 1FSPF Unicast Routes---------------------------

4-8Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 9: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

VSAN Number Dest Domain Route Cost Next hops----------------------------------------------- 1 0x61(97) 500 fc1/5 1 0x62(98) 750 fc1/1 1 0x66(102) 250 fc1/1 1 0x7f(127) 250 fc1/25

MDS9513# sh fcns database vsan 1 VSAN 1:--------------------------------------------------------------------------FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE--------------------------------------------------------------------------0x610e13 N 10:00:00:00:c9:41:80:3e (Emulex) scsi-fcp:init0x611479 NL 22:00:00:20:37:88:e6:da (Seagate) scsi-fcp:target0x61147c NL 22:00:00:20:37:a8:87:50 (Seagate) scsi-fcp:target0x6608e8 NL 50:00:cc:a0:02:48:3e:71 scsi-fcp:target0x661400 N 21:01:00:1b:32:a2:a6:19 (Qlogic) scsi-fcp:init0x7f0a00 N 20:07:00:a0:b8:18:bc:a1 (SymBios) scsi-fcp:target0x7f1200 N 10:00:00:00:c9:d0:8a:82 (Emulex) ipfc scsi-fcp

Total number of entries = 7

The following examples show the commands used to verify the configuration of the MDS 9509 switch (see Figure 4-1):

MDS9509# show versionCisco Nexus Operating System (NX-OS) SoftwareTAC support: http://www.cisco.com/tacDocuments: http://www.cisco.com/en/US/products/ps9372/tsd_products_support_series_home.htmlCopyright (c) 2002-2011, Cisco Systems, Inc. All rights reserved.The copyrights to certain works contained herein are owned byother third parties and are used and distributed under license.Some parts of this software are covered under the GNU PublicLicense. A copy of the license is available athttp://www.gnu.org/licenses/gpl.html.

Software BIOS: version 1.0.10 loader: version N/A kickstart: version 5.2(1) system: version 5.2(1) BIOS compile time: 01/08/09 kickstart image file is: bootflash:///m9500-sf2ek9-kickstart-mz.5.2.1.bin.S74 kickstart compile time: 12/25/2020 12:00:00 [07/16/2011 22:48:52] system image file is: bootflash:///m9500-sf2ek9-mz.5.2.1.bin.S74 system compile time: 6/7/2011 13:00:00 [07/17/2011 00:15:24]

Hardware cisco MDS 9509 (9 Slot) Chassis ("Supervisor/Fabric-2a") Motorola, 7447A, altivec with 2071296 kB of memory. Processor Board ID JAE1213CR8H

Device name: MDS9509 bootflash: 1000440 kB slot0: 0 kB (expansion flash)

Kernel uptime is 5 day(s), 23 hour(s), 33 minute(s), 39 second(s)

Last reset at 831845 usecs after Wed Aug 3 22:36:11 2011

4-9Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 10: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

Reason: Reset Requested by CLI command reload System version: 5.2(1) Service:

plugin Core Plugin

MDS9509# show int brief -------------------------------------------------------------------------------Interface Vsan Admin Admin Status SFP Oper Oper Port Mode Trunk Mode Speed Channel Mode (Gbps)-------------------------------------------------------------------------------fc2/1 1 FX on sfpAbsent -- -- --fc2/2 1 FX on sfpAbsent -- -- --fc3/1 1 auto on up swl E 4 --fc3/2 1 FX on down swl -- --fc3/3 1 FX on sfpAbsent -- -- --fc3/4 1 FX on down swl -- --fc3/5 1 auto on up swl E 2 --fc3/6 1 FX on down swl -- --fc3/11 1 FX on down swl -- --fc3/12 1 FX on down swl -- --fc3/13 1 auto on down swl -- --fc3/20 1 FX on down swl -- --fc3/21 1 FX on down swl -- --fc3/24 1 FX on down swl -- --fc3/25 1 auto on up swl E 4 --fc3/26 1 FX on down swl -- --fc3/27 1 FX on sfpAbsent -- -- --

MDS9509(config)# show vsan 1vsan 1 information name:VSAN0001 state:active interoperability mode:default loadbalancing:src-id/dst-id/oxid operational state:up

MDS9509(config)# show fcdomain vsan 1The local switch is the Principal Switch.

Local switch run time information: State: Stable Local switch WWN: 20:01:00:05:9b:00:11:5f Running fabric name: 20:01:00:05:9b:00:11:5f Running priority: 2 Current domain ID: 0x62(98)

Local switch configuration information: State: Enabled FCID persistence: Enabled Auto-reconfiguration: Disabled Contiguous-allocation: Disabled Configured fabric name: 20:01:00:05:30:00:28:df Optimize Mode: Disabled Configured priority: 128 Configured domain ID: 0x62(98) (preferred)

Principal switch run time information: Running priority: 2

Interface Role RCF-reject---------------- ------------- ------------

4-10Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 11: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

fc3/1 Non-principal Disabledfc3/5 Downstream Disabledfc3/25 Non-principal Disabled---------------- ------------- ------------

MDS9509(config)# show fcdomain domain-list vsan 1

Number of domains: 5Domain ID WWN--------- ----------------------- 0x62(98) 20:01:00:05:9b:00:11:5f [Local] [Principal] 0x61(97) 10:00:08:00:88:60:30:540x64(100) 20:01:00:05:9b:01:b4:b30x66(102) 10:00:00:05:1e:03:ae:560x7f(127) 10:00:00:05:1e:c4:3f:63

MDS9509(config)# show fspf internal route vsan 1

FSPF Unicast Routes--------------------------- VSAN Number Dest Domain Route Cost Next hops----------------------------------------------- 1 0x61(97) 500 fc3/5 1 0x64(100) 750 fc3/1 fc3/25 1 0x66(102) 250 fc3/1 1 0x7f(127) 250 fc3/25

MDS9509(config)# show fcns database vsan 1

VSAN 1:--------------------------------------------------------------------------FCID TYPE PWWN (VENDOR) FC4-TYPE:FEATURE--------------------------------------------------------------------------0x610e13 N 10:00:00:00:c9:41:80:3e (Emulex) scsi-fcp:init0x611479 NL 22:00:00:20:37:88:e6:da (Seagate) scsi-fcp:target0x61147c NL 22:00:00:20:37:a8:87:50 (Seagate) scsi-fcp:target0x6608e8 NL 50:00:cc:a0:02:48:3e:71 scsi-fcp:target0x661400 N 21:01:00:1b:32:a2:a6:19 (Qlogic) scsi-fcp:init0x7f0a00 N 20:07:00:a0:b8:18:bc:a1 (SymBios) scsi-fcp:target0x7f1200 N 10:00:00:00:c9:d0:8a:82 (Emulex) ipfc scsi-fcp

Total number of entries = 7

Verifying the Brocade 4900 SwitchThe following examples show the commands used to verify the configuration of the Brocade 4900 switch (see Figure 4-1):

BRCD4900:root> versionKernel: 2.6.14.2Fabric OS: v6.4.1aMade on: Tue Dec 14 02:34:02 2010Flash: Thu Jul 14 00:30:40 2011BootProm: 4.6.6

BRCD4900:root> licenseshowedbdQRRyfeceRl: Fabric license

BRCD4900:root> switchshow

4-11Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 12: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

switchName: BRCD4900switchType: 44.2switchState: OnlineswitchMode: McDATA Open FabricswitchRole: SubordinateDomainIDOffset: 0x60switchDomain: 102switchId: fffc66switchWwn: 10:00:00:05:1e:03:ae:56zoning: ON (mds1)switchBeacon: OFF

Index Port Address Media Speed State Proto============================================== 0 0 660000 id N4 No_Sync FC Disabled (Persistent) 1 1 660100 id N4 No_Light FC 2 2 660200 id N4 No_Light FC 3 3 660300 id N4 No_Light FC 4 4 660400 id N4 No_Sync FC Disabled (Persistent) 5 5 660500 id N2 No_Light FC 6 6 660600 id N4 No_Light FC 7 7 660700 id N4 No_Light FC 8 8 660800 id 2G Online FC L-Port 1 public 9 9 660900 id N2 Online FC E-Port segmented,(Op Mode incompat) 10 10 660a00 id N4 No_Light FC 11 11 660b00 id N4 Mod_Val FC 12 12 660c00 id 2G No_Light FC 13 13 660d00 id N2 Online FC E-Port segmented,(Op Mode incompat) 19 19 661300 id 2G No_Light FC 20 20 661400 id 2G Online FC F-Port 21:01:00:1b:32:a2:a6:19 24 24 661800 id N4 In_Sync FC 25 25 661900 id N4 Online FC E-Port 20:01:00:05:9b:01:b4:b3 "MDS9513" (upstream) 26 26 661a00 id N4 No_Light FC 27 27 661b00 -- N4 No_Module FC 28 28 661c00 -- N4 No_Module FC 29 29 661d00 id N4 Online FC E-Port 20:01:00:05:9b:00:11:5f "MDS9509" 30 30 661e00 id N4 No_Light FC

BRCD4900:root> topologyshow

5 domain(s) in the fabric; Local Domain ID: 102

Domain: 97Metric: 1000Name: MCD-4500Path Count: 2

Hops: 2 Out Port: 25 In Ports: 8 20 Total Bandwidth: 4.000 Gbps Bandwidth Demand: 300 % Flags: D

Hops: 2 Out Port: 29 In Ports: 8 20 Total Bandwidth: 4.000 Gbps Bandwidth Demand: 300 % Flags: D

Type <CR> to continue, Q<CR> to stop:Domain: 98

4-12Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 13: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

Metric: 500Name: MDS9509Path Count: 1

Hops: 1 Out Port: 29 In Ports: 8 20 25 Total Bandwidth: 4.000 Gbps Bandwidth Demand: 300 % Flags: D

Type <CR> to continue, Q<CR> to stop:Domain: 100Metric: 500Name: MDS9513Path Count: 1

Hops: 1 Out Port: 25 In Ports: 8 20 29 Total Bandwidth: 4.000 Gbps Bandwidth Demand: 300 % Flags: D

Type <CR> to continue, Q<CR> to stop:Domain: 127Metric: 750Name: BR_5100Path Count: 2

Hops: 2 Out Port: 25 In Ports: 8 20 Total Bandwidth: 4.000 Gbps Bandwidth Demand: 300 % Flags: D

Hops: 2 Out Port: 29 In Ports: 8 20 Total Bandwidth: 4.000 Gbps Bandwidth Demand: 300 % Flags: D

BRCD4900:root> nsshow{ Type Pid COS PortName NodeName TTL(sec) NL 6608e8; 3;50:00:cc:a0:02:48:3e:71;50:00:cc:a0:02:08:3e:71; na FC4s: FCP [HITACHI HUS151436VLF400 F420] Fabric Port Name: 20:08:00:05:1e:03:ae:56 Permanent Port Name: 50:00:cc:a0:02:48:3e:71 Port Index: 8 Share Area: No Device Shared in Other AD: No Redirect: No Partial: No N 661400; 3;21:01:00:1b:32:a2:a6:19;20:01:00:1b:32:a2:a6:19; na FC4s: FCP NodeSymb: [43] "QLE2562 FW:v4.04.09 DVR:v8.03.00.10.05.04-k" Fabric Port Name: 20:14:00:05:1e:03:ae:56 Permanent Port Name: 21:01:00:1b:32:a2:a6:19 Port Index: 20 Share Area: No Device Shared in Other AD: No

4-13Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 14: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

Redirect: No Partial: NoThe Local Name Server has 2 entries }

BRCD4900:root> nsallshow{610e13 611479 61147c 6608e8 661400 7f0a00 7f12007 Nx_Ports in the Fabric }

BRCD4900:root> urouteshow

Local Domain ID: 102

In Port Domain Out Port Metric Hops Flags Next (Dom, Port)---------------------------------------------------------------------------- 8 97 25 1000 2 D 100,65536 97 29 1000 2 D 98,66048 98 29 500 1 D 98,66048 100 25 500 1 D 100,65536 127 25 750 2 D 100,65536 127 29 750 2 D 98,66048

Type <CR> to continue, Q<CR> to stop:

20 97 25 1000 2 D 100,65536 97 29 1000 2 D 98,66048 98 29 500 1 D 98,66048 100 25 500 1 D 100,65536 127 25 750 2 D 100,65536 127 29 750 2 D 98,66048

Type <CR> to continue, Q<CR> to stop:

25 98 29 500 1 D 98,66048

Type <CR> to continue, Q<CR> to stop:

29 100 25 500 1 D 100,65536

Type <CR> to continue, Q<CR> to stop:

You can use Cisco DCNM-SAN and Device Manager to verify the current state of the fabric.

Figure 4-2 shows the fabric topology using Cisco DCNM-SAN.

4-14Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 15: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

Figure 4-2 MDS 9509 Switch DCNM-SAN Map

Figure 4-3 shows Cisco Device Manager on an MDS 9513 switch in the example topology. This shows which ports are active E ports.

4-15Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 16: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

Figure 4-3 MDS 9513 Switch Device Manager

Figure 4-4 shows the status of the E ports and can verify link speed.

Figure 4-4 MDS 9513 Switch E ports

Figure 4-5 shows the domain ID of the switches in the fabric.

4-16Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 17: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

Figure 4-5 MDS 9513 Switch Domain Manager

Figure 4-6 shows that VSAN 1 is operating in interop mode.

Figure 4-6 VSAN 1 Operating in Interop Mode on an MDS 9513 Switch

Figure 4-7 shows the MDS 9513 switch name server. This shows the edge devices that have registered.

Figure 4-7 MDS 9513 Switch Name Server Showing McData and Brocade Devices

Figure 4-8 shows the FSPF routes as calculated by this switch.

4-17Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 18: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

Figure 4-8 MDS 9513 Switch Showing FC Routes

Verifying the Brocade 5100 SwitchThe following examples show the commands used to verify the configuration of the Brocade 5100 switch (see Figure 4-1):

Kernel: 2.6.14.2Fabric OS: v6.3.2aMade on: Thu Sep 2 17:37:01 2010Flash: Wed Mar 2 09:52:19 2011BootProm: 1.0.9

BR_5100:root> licenseshowbb9bzeSQzyccAc0O: Fabric licenseA33WLgfYSPXX9AmtHmt9NgCCJrftTQJmBALNR: Enhanced Group Management licenseYABr4NYRQFRFtJW44C3PHSEgWRD9RD7QB7rAJ: 8 Gig FC license

BR_5100:root> switchshowswitchName: BR_5100switchType: 66.1switchState: OnlineswitchMode: McDATA Open FabricswitchRole: SubordinateDomainIDOffset: 0x60switchDomain: 127switchId: fffc7fswitchWwn: 10:00:00:05:1e:c4:3f:63zoning: ON (mds1)switchBeacon: OFFFC Router: OFFFC Router BB Fabric ID: 1

Index Port Address Media Speed State Proto============================================== 0 0 7f0000 id N8 No_Light FC 1 1 7f0100 id N8 No_Light FC 2 2 7f0200 id N8 No_Light FC Disabled (Persistent) 3 3 7f0300 id N8 No_Light FC Disabled (Persistent) 4 4 7f0400 id N8 No_Light FC Disabled (Persistent) 5 5 7f0500 id N8 No_Light FC Disabled (Persistent) 6 6 7f0600 id N8 No_Light FC 7 7 7f0700 id N8 No_Light FC

4-18Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 19: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

8 8 7f0800 id N8 No_Light FC Disabled (Persistent) 9 9 7f0900 id N8 No_Light FC Disabled (Persistent) 10 10 7f0a00 id 2G Online FC F-Port 20:07:00:a0:b8:18:bc:a1 11 11 7f0b00 id 2G In_Sync FC 12 12 7f0c00 id N8 No_Light FC 13 13 7f0d00 id 2G No_Light FC 14 14 7f0e00 id N2 In_Sync FC 15 15 7f0f00 id 2G No_Light FC 16 16 7f1000 id N8 No_Sync FC Disabled (Persistent) 17 17 7f1100 id N8 No_Sync FC Disabled (Persistent) 18 18 7f1200 id 4G Online FC F-Port 10:00:00:00:c9:d0:8a:82 19 19 7f1300 id N8 No_Light FC 20 20 7f1400 id N8 No_Sync FC Disabled (Persistent) 21 21 7f1500 id N8 No_Sync FC Disabled (Persistent) 22 22 7f1600 id N4 Online FC E-Port 20:01:00:05:9b:00:11:5f "MDS9509" 23 23 7f1700 id N4 Online FC E-Port 20:01:00:05:9b:01:b4:b3 "MDS9513" (upstream)

BR_5100:root> nsshow{ Type Pid COS PortName NodeName TTL(sec) N 7f0a00; 3;20:07:00:a0:b8:18:bc:a1;20:06:00:a0:b8:18:bc:a0; na FC4s: FCP [LSI INF-01-00 0612] Fabric Port Name: 20:0a:00:05:1e:c4:3f:63 Permanent Port Name: 20:07:00:a0:b8:18:bc:a1 Port Index: 10 Share Area: No Device Shared in Other AD: No Redirect: No N 7f1200; 2,3;10:00:00:00:c9:d0:8a:82;20:00:00:00:c9:d0:8a:82; na FC4s: IPFC FCP PortSymb: [34] "Emulex PPN-10:00:00:00:C9:D0:8A:82" NodeSymb: [57] "Emulex LPe12002-M8 FV1.10A5 DV5.2.40.005 LABD-HOST180-HN" Fabric Port Name: 20:12:00:05:1e:c4:3f:63 Permanent Port Name: 10:00:00:00:c9:d0:8a:82 Port Index: 18 Share Area: No Device Shared in Other AD: No Redirect: NoThe Local Name Server has 2 entries }

BR_5100:root> ntopologyshow5 domain(s) in the fabric; Local Domain ID: 127

Domain: 97Metric: 1000Name: MCD-4500Path Count: 2

Hops: 2 Out Port: 23 In Ports: 10 18 Total Bandwidth: 4.000 Gbps Bandwidth Demand: 400 % Flags: D

Hops: 2 Out Port: 22 In Ports: 10 18 Total Bandwidth: 4.000 Gbps Bandwidth Demand: 400 % Flags: D

4-19Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 20: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

Type <CR> to continue, Q<CR> to stop:Domain: 98Metric: 500Name: MDS9509Path Count: 1

Hops: 1 Out Port: 22 In Ports: 10 18 23 Total Bandwidth: 4.000 Gbps Bandwidth Demand: 400 % Flags: D

Type <CR> to continue, Q<CR> to stop:Domain: 100Metric: 500Name: MDS9513Path Count: 1

Hops: 1 Out Port: 23 In Ports: 10 18 22 Total Bandwidth: 4.000 Gbps Bandwidth Demand: 400 % Flags: D

Type <CR> to continue, Q<CR> to stop:Domain: 102Metric: 750Name: BRCD4900Path Count: 2

Hops: 2 Out Port: 23 In Ports: 10 18 Total Bandwidth: 4.000 Gbps Bandwidth Demand: 400 % Flags: D

Hops: 2 Out Port: 22 In Ports: 10 18 Total Bandwidth: 4.000 Gbps Bandwidth Demand: 400 % Flags: D

BR_5100:root> nsallshow{610e13 611479 61147c 6608e8 661400 7f0a00 7f12007 Nx_Ports in the Fabric }

BR_5100:root> urouteshow Local Domain ID: 127

In Port Domain Out Port Metric Hops Flags Next (Dom, Port)---------------------------------------------------------------------------- 10 97 22 1000 2 D 98,66072 97 23 1000 2 D 100,65560 98 22 500 1 D 98,66072 100 23 500 1 D 100,65560 102 22 750 2 D 98,66072 102 23 750 2 D 100,65560

4-20Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 21: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

Type <CR> to continue, Q<CR> to stop:

18 97 22 1000 2 D 98,66072 97 23 1000 2 D 100,65560 98 22 500 1 D 98,66072 100 23 500 1 D 100,65560 102 22 750 2 D 98,66072 102 23 750 2 D 100,65560

Type <CR> to continue, Q<CR> to stop:

22 100 23 500 1 D 100,65560

Type <CR> to continue, Q<CR> to stop:

23 98 22 500 1 D 98,66072

4-21Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 22: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

Verifying the McData 4500 SwitchIssue the show switch command to show current switch information.

Root> show switchState: OnlineR_A_TOV: 100E_D_TOV: 20Preferred Domain ID: 1Domain ID Offset: 96Switch Priority: Never PrincipalRerouting Delay: DisabledInterop Mode: Open Fabric 1.0Active Domain ID: 1World Wide Name: 10:00:08:00:88:60:30:54Insistent Domain ID: DisabledDomain RSCN: EnabledZoning RSCN: EnabledFC Address Domain: 61 (hex)Limited Fabric RSCN: DisabledZone FlexPars: Fabric FilteringRSCN Zone Isolation: Fabric FilteringSafe Zoning: DisabledISL FSPF Cost: Ignore Port SpeedWeb Enabled: EnabledFrame Resize State: EnabledBlock Dup WWN State: DisabledAPI Enabled: EnabledAPI Management IP: 172.25.242.37Password Exp. Time: 0

Issue the show system command to show current system information.

Root> show systemName: MCD-4500Description: McData 4500 Fibre Channel SwitchContact: Field SupportLocation: Lab DDate/Time: 08/09/2011 15:54:51Serial Number:Type Number:Model Name:Model Number:EC Level:Firmware Version: 09.09.09 2Beaconing: Disabled

Issue the show port status command to verify that the correct ports are online and are of type E port or F port.

Root> show port statusPort State Type Attached WWN Beaconing Reason---- ------------------ ------ ----------------------- --------- ------0 No Light ePort None Disabled1 Offline fxPort None Disabled2 No Light gxPort None Disabled3 Offline gxPort None Disabled4 No Light ePort None Disabled5 No Light ePort None Disabled6 Offline ePort None Disabled7 Offline ePort None Disabled8 No Light gxPort None Disabled9 Offline fPort None Disabled

4-22Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 23: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

10 Online fPort 10:00:00:00:C9:41:80:3E Disabled11 Offline gxPort None Disabled12 Offline gxPort None Disabled13 No Light gxPort None Disabled14 Offline gxPort None Disabled15 No Light gxPort None Disabled16 Online flPort MULTIPLE (LOOP) Disabled17 Offline gxPort None Disabled18 No Light gxPort None Disabled19 Offline gxPort None Disabled20 Offline gxPort None Disabled21 Online ePort 20:01:00:05:9B:00:11:5F Disabled22 No Light gxPort None Disabled23 Online ePort 20:01:00:05:9B:01:B4:B3 Disabled

Root> show loginserverPort BB Crdt RxFldSz COS Port Name Node Name---- ------- ------- --- ----------------------- -----------------------10 16 2048 2-3 10:00:00:00:C9:41:80:3E 20:00:00:00:C9:41:80:3E16 0 2112 3 22:00:00:20:37:88:E6:DA 20:00:00:20:37:88:E6:DA16 0 2112 3 22:00:00:20:37:A8:87:50 20:00:00:20:37:A8:87:50

Root> show fabric routeIngress DID Egress Rem Did Rem Ingress Hops Act Cost Eff Cost PPath------- --- ------ ------- ----------- ---- -------- -------- -----10 2 21 2 FC3/5 1 1000 1000 No10 4 23 4 FC1/5 1 1000 1000 No10 6 21 2 FC3/5 2 1250 1250 No10 31 21 2 FC3/5 2 1250 1250 No16 2 21 2 FC3/5 1 1000 1000 No16 4 23 4 FC1/5 1 1000 1000 No16 6 23 4 FC1/5 2 1250 1250 No16 31 23 4 FC1/5 2 1250 1250 No21 4 23 4 FC1/5 1 1000 1000 No23 2 21 2 FC3/5 1 1000 1000 NoRoot> show fabric topologySwitch WWN DID OutPrt Remote WWN RemDID RemPort------------------------ --- ----------- ----------------------- ------ --------10:00:08:00:88:60:30:54 1 21UP 20:01:00:05:9B:00:11:5F 2 FC3/5 23DN 20:01:00:05:9B:01:B4:B3 4 FC1/520:01:00:05:9B:00:11:5F* 2 FC3/1 10:00:00:05:1E:03:AE:56 6 29 FC3/5 10:00:08:00:88:60:30:54 1 21 FC3/25 10:00:00:05:1E:C4:3F:63 31 2220:01:00:05:9B:01:B4:B3 4 FC1/1 10:00:00:05:1E:03:AE:56 6 25 FC1/25 10:00:00:05:1E:C4:3F:63 31 23 FC1/5 10:00:08:00:88:60:30:54 1 2310:00:00:05:1E:03:AE:56 6 25 20:01:00:05:9B:01:B4:B3 4 FC1/1 29 20:01:00:05:9B:00:11:5F 2 FC3/110:00:00:05:1E:C4:3F:63 31 22 20:01:00:05:9B:00:11:5F 2 FC3/25 23 20:01:00:05:9B:01:B4:B3 4 FC1/25

To view the FSPF routes used by the McData 4500 switch, use the WebTools GUI (see Figure 4-9 and Figure 4-10). There is no command line display available to show this information.

4-23Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 24: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Verification

Figure 4-9 McData 4500 Switch FSPF Routes

Figure 4-10 McData 4500 Switch Topology View

4-24Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 25: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Zoning

ZoningIn this section, the zones and zone sets are created using Cisco DCNM-SAN (see Figure 4-11.) Cisco DCNM-SAN is also used to verify the zoning, along with the Brocade and McData switch command line displays.

This section includes the following topics:

• Verifying Zoning with Cisco DCNM-SAN, page 4-25

• Verifying Zoning with the Brocade 4900 Switch, page 4-28

• Verifying Zoning with the Brocade 5100 Switch, page 4-28

• Verifying Zoning with the McData 4500 Switch, page 4-28

Figure 4-11 Configuring Zones in Cisco DCNM-SAN

Verifying Zoning with Cisco DCNM-SANFigure 4-12 shows the zone VZ1 on Cisco DCNM-SAN.

4-25Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 26: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Zoning

Figure 4-12 VZ1 on Cisco DCNM-SAN

Figure 4-13 shows the zone VZ2 on DCNM-SAN.

Figure 4-13 Highlighting Zone VZ2 in DCNM-SAN

Figure 4-14 shows the zone VZ3 on DCNM-SAN.

4-26Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 27: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Zoning

Figure 4-14 Highlighting Zone VZ3 in DCNM-SAN

4-27Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 28: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Zoning

Verifying Zoning with the Brocade 4900 SwitchThe following examples show the commands used to verify zoning for the Brocade 4900 switch (see Figure 4-1):

BRCD900:root> cfgshowDefined configuration: no configuration defined

Effective configuration: cfg: mdszoneset1 zone: vz1 50:00:cc:a0:02:48:3e:71 10:00:00:00:c9:41:80:3e zone: vz2 20:07:00:a0:b8:18:bc:a1 21:01:00:1b:32:a2:a6:19 zone: vz3 10:00:00:00:c9:d0:8a:82 22:00:00:20:37:a8:87:50 22:00:00:20:37:88:e6:da

Verifying Zoning with the Brocade 5100 SwitchThe following examples show the commands used to verify zoning for the Brocade 5100 switch (see Figure 4-1):

BR_5100:root> cfgshowDefined configuration: no configuration defined

Effective configuration: cfg: mdszoneset1 zone: vz1 50:00:cc:a0:02:48:3e:71 10:00:00:00:c9:41:80:3e zone: vz2 20:07:00:a0:b8:18:bc:a1 21:01:00:1b:32:a2:a6:19 zone: vz3 10:00:00:00:c9:d0:8a:82 22:00:00:20:37:a8:87:50 22:00:00:20:37:88:e6:da

Verifying Zoning with the McData 4500 SwitchThe following examples show the commands used to verify zoning for the McData 4500 switch in the configuration (see Figure 4-1):

Root> show zoningDefault Zone Enabled: FalseZone Set: mdszoneset1 Zone: vz1 Zone Member: 50:00:CC:A0:02:48:3E:71 Zone Member: 10:00:00:00:C9:41:80:3E Zone: vz2 Zone Member: 20:07:00:A0:B8:18:BC:A1 Zone Member: 21:01:00:1B:32:A2:A6:19 Zone: vz3 Zone Member: 10:00:00:00:C9:D0:8A:82 Zone Member: 22:00:00:20:37:A8:87:50 Zone Member: 22:00:00:20:37:88:E6:DA

4-28Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 29: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Zoning

Figure 4-15 shows the FSPF traffic flow in this multi-vendor fabric.

Figure 4-15 Data Flow of Dual MDS 9509 Switch Core with Brocade and McData Switch Edge

Topology

4-29Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02

Page 30: MDS 9000 Core with Brocade and McData Edge …...Brocade 5100. These paths are running at 2 Gbps and appear with a cost of 500. The Brocade switches load balance their routes using

Send documenta t ion comments to mdsfeedback -doc@c i sco .com

Chapter 4 MDS 9000 Core with Brocade and McData Edge Topology (Interop Mode 1) Zoning

4-30Cisco MDS 9000 Family Switch-to-Switch Interoperability Configuration Guide

OL-25752-02