    DRAFT - Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 24/04/20091

    Well Analyzer y Programa TWM

    Manual de Operacin

    Copyright 2009All Rights Reserved

    ECHOMETER COMPANY

    5001 Ditto LaneWichita Falls, Texas, USA

    Phone: (940) 767-4334 FAX: (940) 723-7507E-MAIL: [email protected] www.echometer.com

  • 7/30/2019 Manual Twm 2009

    2/353

    DRAFT - Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 24/04/20092

    INTRODUCCIN................................................................................................................................................................8Seguridad .........................................................................................................................................................................8Como Usar este Manual ...................................................................................................................................................8Organizacin de los Temas ..............................................................................................................................................8

    1. OBJETIVOS DEL ANALIZADOR DE POZO ...............................................................................................................92. GENERALIDADES DE LAS APLICACIONES DEL ANALIZADOR DE POZO .....................................................122.1 Registros Acsticos en Pozos...................................................................................................................................12

    2.2 Estudios con el Dinammetro ..................................................................................................................................132.3 Anlisis del Balanceo de la Unidad de Bombeo Mecnico y del Torque.................................................................132.4 Pruebas de Presin Transitoria.................................................................................................................................142.5 Monitoreo del Nivel del Lquido..............................................................................................................................15

    2.5.1 Operaciones para Matar el Pozo y para Reacondicionamiento.........................................................................162.5.2 Monitoreo del Tratamiento por Baches.............................................................................................................16

    2.6 Pruebas Especiales ...................................................................................................................................................162.6.1 Levantamiento Artificial Neumtico (Gaslift) .................................................................................................162.6.2 Prueba de la Vlvula de Seguridad del Subsuelo..............................................................................................162.6.3 Registros de la Presin de Fondo del Pozo a travs de la Tubera de Produccin ............................................162.6.4 Desplazamiento de Lquido en la Tubera de Produccin.................................................................................172.6.5 Bombeo Neumtico Con Pistn ........................................................................................................................172.6.6 Pozos de Gas.....................................................................................................................................................17

    3. GENERALIDADES ACERCA PROGRAMAS USADOS CON EL Well Analyzer....................................................183.1 Programas.................................................................................................................................................................18

    Programa para el Diseo de la Unidad de Bombeo ...................................................................................................183.1.1 Uso del Teclado y del Ratn .................................................................................................................................18

    Teclas de Funciones...................................................................................................................................................19Tecla Tab ...................................................................................................................................................................19Tecla Alt ....................................................................................................................................................................19

    3.2 Ambiente..................................................................................................................................................................213.2.1 Barra del Men .................................................................................................................................................21

    3.2.2 Men de Archivo (File Menu)......................................................................................................................213.2.3 Men de la Modalidad (Mode Menu)...........................................................................................................223.2.4 Men de Opciones (Option Menu) ...............................................................................................................22

    3.2.5 Men de Herramientas (Tool Menu) ............................................................................................................223.2.6 Men de Ayuda ............................................................................................................................................28

    3.2.7 La Barra de Dialogo..........................................................................................................................................313.2.7.1 Selector de la Modalidad de Uso (Mode Selector) ....................................................................................313.2.7.2 Botones de Opciones .................................................................................................................................32

    3.2.8 El rea de las Carpetas .....................................................................................................................................323.5 El Sistema de Archivos ............................................................................................................................................33

    3.3.2 Grupos de Pozos en el Archivo TWM ..............................................................................................................333.3.3 Archivos Base de Pozo y Archivos de Datos...................................................................................................333.3.4 Transferimiento de Archivos De Datos a otras Computadoras .....................................................................34

    3.4 Tipos de Computadores............................................................................................................................................363.5 Generalidades de los Sistemas del Computador.......................................................................................................36

    3.5.1 Dando Formato a los Discos .............................................................................................................................363.5.2 Nombres de los Archivos..................................................................................................................................363.5.3 Tipos de Archivos.............................................................................................................................................373.5.4 Administracin de Archivos .............................................................................................................................373.5.5 Directorios ........................................................................................................................................................37

    3.6 Cuidados con el A/D y el Computador.....................................................................................................................373.7 Deteccin de Fallas del Computador........................................................................................................................373.8 Cargando Bateras ....................................................................................................................................................38

    3.8.1 Fusibles .............................................................................................................................................................383.8.2 Instrucciones Importantes para Recargar Bateras ............................................................................................383.8.3 Notas acerca del Uso de las Bateras.................................................................................................................38

    4.0 PROCEDIMIENTO PARA ESTUDIO ACSTICO DEL POZO ..............................................................................404.1 Resumen de las Instrucciones de Operacin ............................................................................................................404.2 Configuracin del Sistema .......................................................................................................................................43

    4.2.1 Descripcin del Equipo.....................................................................................................................................43

  • 7/30/2019 Manual Twm 2009

    3/353

    DRAFT - Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 24/04/20093

    4.2.1.1 Computador ...............................................................................................................................................434.2.1.2 Analizador de Pozo....................................................................................................................................44

    4.2.2 Uso de Pistola a Gas Disparada Remotamente (WG) .......................................................................................444.2.2.1 Solenoide y Vlvula de Gas ...................................................................................................................... 444.2.2.2 Manmetro WG.........................................................................................................................................454.2.2.3 Transductor de Presin ..............................................................................................................................454.2.2.4 Adaptador de 2 Pulgadas ........................................................................................................................454.2.2.5 Como Cargar la Cmara de Gas ................................................................................................................ 454.2.2.6 Conexin de la Pistola al Pozo ..................................................................................................................46

    4.2.3 Como Usar la Pistola Compacta de Gas ...........................................................................................................464.2.3.1 Pulso de Explosin .................................................................................................................................... 464.2.3.2 Pulso de Implosin ....................................................................................................................................464.2.3.3 Manmetro de Presin...............................................................................................................................484.2.3.4 Conector Rpido a la Presin del Revestimiento.......................................................................................484.2.3.5 Adaptador de 2 Pulgadas ........................................................................................................................484.2.3.6 Palanca de Carga .......................................................................................................................................484.2.3.7 Vlvula de Alivio de la Presin del Revestimiento ...................................................................................494.2.3.8 Vlvula de Alivio/Llenado de la Cmara ..................................................................................................494.2.3.9 Gatillo........................................................................................................................................................494.2.3.10 Micrfono................................................................................................................................................49

    4.2.4 Como Usar la Pistola a Gas de Alta Presin ..................................................................................................... 494.3 Operacin y Mantenimiento del Equipo ..................................................................................................................51

    4.3.1 Conexiones Mecnicas y Elctricas..................................................................................................................514.3.2 Como Recargar el Cilindro de 7.5 Onzas de CO2 .............................................................................................51

    4.3.3 Como Recargar los Cilindros de CO2 de 2.5 o de 5 Libras de Capacidad ..................................................524.3.4 Videos de Ayuda para el Mantenimiento de las Pistolas a Gas ........................................................................52

    5. PROGRAMA ADMINISTRACION COMPLETA DEL POZO (TWM) ......................................................................535.1 Manejo del Programa TWM ....................................................................................................................................53

    5.1.1 Negacin de Garanta........................................................................................................................................535.1.2 Pantallas De Inicializacin................................................................................................................................545.1.3 Seccin de Chequeo del Equipo (Equipment Check) .......................................................................................545.1.4 Seccin del Sensor Acstico (Acoustic Sensor)-Medidas Acsticas BHP ....................................................... 55

    5.1.5 Seccin del Sensor del Dinammetro (Dynamometer Sensor)-Medidas del Dinammetro .............................565.1.6 Seccin Pozos Neumticos de Pistn (Plunger Wells) .................................................................................. 58

    5.2 Informacin en el Archivo Base del Pozo ................................................................................................................ 585.2.1 Pantalla Gua de Datos (data Guide).............................................................................................................. 595.2.2 Bombeo Mecnico -Informacin en el Archivo del Pozo.................................................................................615.2.2.1 Seccin General (General) Definicin de los Espacios a Llenar ................................................................625.2.2.2 Equipo de Superficie (Surface Equip.) Definicin de los Espacios a Llenar..............................................635.2.2.3 Seccin Pozo (Wellbore). Definicin de los Espacios a Llenar..................................................................665.2.2.4 Seccin Condiciones (Conditions) Definicin de los Espacios a Llenar ....................................................695.2.3 Pozos con Bombas Electro-Sumergibles .......................................................................................................73

    5.2.3.1 Seccin General Pozo BES.................................................................................................................. 735.2.3.2 - Seccin Equipo de Subsuelo Pozo BES ..............................................................................................745.2.3.3 Seccin Equipo Elctrico Pozo BES ...................................................................................................75

    5.2.4 Pozo de Gas Fluyente .................................................................................................................................... 765.2.4.1 Seccin General Flowing Gas Well..................................................................................................... 765.2.4.2 Seccin Equipo de Superficie Pozo de Gas.........................................................................................765.2.4.3 Seccin Completamiento del Pozo Pozo de Gas ................................................................................. 775.2.4.4 Seccin Condiciones Pozo de Gas.......................................................................................................77

    5.2.5 Pozo de Gaslift con Pistn (Plunger Lift Well) .............................................................................................785.2.5.1 Seccin General Plunger Lift Well......................................................................................................785.2.5.2 Seccin Equipo de Superficie Plunger Lift Well ................................................................................. 785.2.5.3 Seccin Completamiento del Pozo Plunger Lift Well .........................................................................795.2.5.4 Seccin Condiciones Plunger Lift Well ..............................................................................................79

    6.0 Programa para Registros Acsticos de Nivel y Clculo de las Presiones dentro del Pozo.......................................806.1 Adquisicin y Control de Calidad de Registros Acsticos .................................................................................. 80

    6.2 Anlisis del Registro de Nivel y Clculo de Presiones en el Pozo ...........................................................................906.2.1 Seccin Determinacin de Profundidad (Depth Determination) ......................................................................90

  • 7/30/2019 Manual Twm 2009

    4/353

    DRAFT - Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 24/04/20094

    6.2.2 Seccin Conteo de Tubos (Collars)...................................................................................................................926.2.3 Opciones de Filtrado.........................................................................................................................................936.2.4 Seccin Presin del Revestimiento (Casing Pressure)......................................................................................946.2.5 Anlisis Manual ................................................................................................................................................956.2.6 Seccin Presin de Fondo de Pozo (BHP)........................................................................................................99

    Liquido Debajo de la Bomba...............................................................................................................................101Parmetros Adicionales .......................................................................................................................................1026.2.6.1 Presin de Fondo Esttica (SBHP) .......................................................................................................1036.2.6.2 Calculo de SBHP Posteriormente a la Adquisicin del Registro.............................................................110

    6.3 Procesamiento Especial de los Datos Acsticos.....................................................................................................1116.3.1 Nivel de Lquido Somero................................................................................................................................1116.3.2 Nivel de Fluido muy Somero..........................................................................................................................1126.3.3 Procesamiento Especial: Entrar Velocidad (Velocity Input) ..........................................................................1146.3.4 - Especificar un Marcador en el Pozo (Specify Downhole Marker) ...............................................................1186.3.5 Pozos Desviados .............................................................................................................................................124

    6.4 Reportes de Resultados .........................................................................................................................................1256.4.1 Impresin del Reporte Acstico......................................................................................................................1256.4.2 Impresin del Reporte Resumen que se Prepara con MS Word .....................................................................128

    6.5 Control de Calidad de los Registros ......................................................................................................................1296.5.1 Deteccin del Nivel de Lquido ......................................................................................................................1296.5.2 Seleccin de la Frecuencia de los Ecos de las Uniones de la Tubera............................................................130

    6.6 Clculo de la Presin de Fondo de Pozo ................................................................................................................1306.6.1 Columnas Lquido Gaseoso ............................................................................................................................1306.6.2 Programas de Clculo de la Presin de Fondo: AWP 2000 ............................................................................131

    5.8 Ejemplo de Registros en Pozos Tpicos .................................................................................................................1326.7.1 Pozo Promedio................................................................................................................................................1325.8.2 Nivel de Lquido Alto, con poco gas o sin gas................................................................................................1336.7.3 Nivel de Lquido Alto, Columna Gaseosa, Pozo con Ruido ...........................................................................1346.7.4 Pozo Profundo.................................................................................................................................................1356.7.5 Ancla de la Tubera.........................................................................................................................................1366.7.6 Tubera Corta de Revestimiento Colgada a 5240 ft ........................................................................................137

    7.0 - PRUEBAS DE PRESIN TRANSITORIA EN POZOS CON UNIDAD DE BOMBEO ......................................139

    7.1 Configuracin del Equipo ......................................................................................................................................1427.1.1 Pistola a Gas....................................................................................................................................................1427.1.2 Transductor de Presin y Termo Resistor .......................................................................................................1427.1.3 Vlvula de Gas y Solenoide............................................................................................................................142

    7.2 Conexiones Elctricas y Mecnicas .......................................................................................................................1427.2.1 Batera.............................................................................................................................................................1427.2.2 Funcionamiento del Transductor de Presin...................................................................................................144

    7.3 Programa TWM: Pruebas de Presin Transitoria...................................................................................................1447.3.1 Datos de Presin Transitoria...........................................................................................................................1467.3.2 Calibracin del Transductor de Presin ..........................................................................................................1477.3.3 Programacin de la Prueba .............................................................................................................................1487.3.4 Frecuencia de Adquisicin de Datos...............................................................................................................1497.3.5 Frecuencia de Almacenamiento de las Trazas Acsticas ................................................................................1497.3.6 Registro de Inicializacin................................................................................................................................1507.3.7 Inicio de la Prueba de Presin Transitoria ......................................................................................................1537.3.8 Progreso y Control de la Prueba .....................................................................................................................154

    7.3.8.1 Respaldo de los Registros........................................................................................................................1567.4 Aadir Registros a un Set de Datos Incompletos ................................................................................................158

    7.4.1 Combinar Data Sets .................................................................................................................................1607.5 - Procedimiento Recomendado para Efectuar Pruebas de Restauracin de Presin ..........................................160

    7.6 Control de Calidad y Anlisis de Registros.........................................................................................................1637.6.1 Anlisis de la Velocidad Acstica...................................................................................................................1637.6.1.1 Procedimiento para Suavizar la Curva de Velocidad...................................................................................165

    7.6.2 Graficando Datos y Resultados vs. Tiempo ........................................................................................................1687.6.3 Editado de Datos ..........................................................................................................................................1707.6.4 Enfoque en una Seccin de Datos................................................................................................................1707.6.4 - Ejemplos de Grficas en Funcin de Tiempo..............................................................................................172

  • 7/30/2019 Manual Twm 2009

    5/353

    DRAFT - Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 24/04/20095

    7.7 - Diagnstico Grfico.............................................................................................................................................1797.7.1 Grficas Log-Log............................................................................................................................................1807.7.2 Derivada de Presin........................................................................................................................................1817.7.3 Grfica MDH..................................................................................................................................................1827.7.4 Grfica Horner ................................................................................................................................................182

    7.8 Recordando Datos ya Registrados..........................................................................................................................1837.8.1 Hoja de Clculo para Correccin de la Presin ..............................................................................................1877.8.1.1 Expansin de la Escala del Tiempo.........................................................................................................188

    7. 9 Exportar un Archivo de BHP............................................................................................................................1917.10 Procesamiento de anlisis de Presin Transiente .................................................................................................192

    7.10.1 Opciones para Transferir Archivos...............................................................................................................1927.10.1.1 Archivos Individuales............................................................................................................................1927.10.1.2 Transferencia Global de Archivos.........................................................................................................194

    8.0 PROGRAMA PARA EL SEGUIMIENTO DEL NIVEL DEL LQUIDO................................................................1958.1 Aplicaciones...........................................................................................................................................................1958.2 Instalacin del Equipo............................................................................................................................................1958.3 Inicializacin del Sistema.......................................................................................................................................1958.4 Operacin...............................................................................................................................................................195

    Chequeo del funcionamiento del equipo y bateras:............................................................................................1968.4.1 Seleccin del Horario......................................................................................................................................1998.4.2 Registro de Inicializacin ...............................................................................................................................2008.4.3 Seleccin del Eco del Nivel ............................................................................................................................2018.4.4 Control de Calidad de la Medicin de Nivel...................................................................................................2028.4.5 Avance de la Prueba (Test Progress) ..............................................................................................................2068.4.6 Control de Calidad del Nivel ..........................................................................................................................208

    8.5 Fijando Limites para Alarmas................................................................................................................................2088.5.1 Alarma: Disparo no se Detecto .......................................................................................................................2118.5.2 Actuacin del Interruptor de 12 V: .................................................................................................................212

    8.5.2.1 Caractersticas del Rel ........................................................................................................................... 2128.6 Uso de Nitrgeno por Largo Tiempo .....................................................................................................................2218.7 Volumen de las Cmaras de Las Pistolas Echometer:............................................................................................222

    9.0 USO Y MEDICIONES DEL DINAMMETRO.......................................................................................................223

    9.0.1 Computador y Programas ...............................................................................................................................2239.0.2 Convertidor de Analgico a Digital (A/D) .....................................................................................................2239.0.3 Celda de Carga tipo Herradura .......................................................................................................................2239.0.4 Celda de Carga tipo Barra Pulida (PRT).........................................................................................................2249.0.5 Celda de Carga tipo herradura con Elevacin Hidrulica ...............................................................................2259.0.6 Sensor de Corriente del Motor........................................................................................................................226

    9.0.6.1 Instalacin del Sensor de Corriente.........................................................................................................2269.0.7 Sensor de Potencia Elctrica del Motor ..........................................................................................................226

    9.1 Programa Dinammetrico...........................................................................................................................................2269.1.1 Inicializacin del Sistema ...............................................................................................................................2269.1.2 Adquiriendo Datos del Dinammetro.............................................................................................................228

    9.1.2.1 Librera de las Unidades de Bombeo....................................................................................................... 2299.1.2.1 Agregando Unidades de Bombeo a la Biblioteca ....................................................................................230

    9.1.2.2 Procedimiento General para la Adquisicin de Datos del Dinammetro.....................................................2349.2 Mediciones con el Transductor de Herradura ........................................................................................................234

    9.2.1 Revisin Inicial de Adquisicin......................................................................................................................2349.2.2 Adquisicin de Datos......................................................................................................................................2359.2.3 Dinagramas.....................................................................................................................................................2419.2.4 Anlisis del Dinammetro - Carreras Individuales .........................................................................................2439.2.4.1 Opciones de Presentacin del Dinagrama....................................................................................................2469.2.5 Ajuste del Factor de Amortiguacin...............................................................................................................2478.3.6 Exportando Datos Dinamomtricos de un ciclo de bombeo ...........................................................................2479.2.7 Anlisis de Torque..........................................................................................................................................248

    9.2.7.1 Desplazamiento de las Contrapesas.........................................................................................................2499.2.7.2 Datos de Potencia Elctrica Registrados con Dinammetro........................................................................250

    Anlisis de Torque en Base a Potencia................................................................................................................250Anlisis de Potencia y Costo de Operacin......................................................................................................... 251

  • 7/30/2019 Manual Twm 2009

    6/353

    DRAFT - Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 24/04/20096

    9.2.8 - Carga de las Varillas ................................................................................................................................2519.2.9 Anlisis de Carga y Corriente.....................................................................................................................253

    9.3 Dinammetro de Herradura con Espaciador y Elevador Hidrulico ......................................................................2559.3.1 Objetivo del Sistema de Elevador Hidrulico .................................................................................................2559.3.2 Descripcin .....................................................................................................................................................256

    9.3.2.1 Celda de Carga ........................................................................................................................................2569.3.2.2 Carrete Espaciador...................................................................................................................................2569.3.2.3 Elevador Hidrulico.................................................................................................................................2569.3.2.4 Plato Espaciador ......................................................................................................................................2569.3.2.5 Bomba Hidrulica....................................................................................................................................256

    9.3.3 Instalacin.......................................................................................................................................................2579.4 Mediciones con el Transductor de Barra Pulida (PRT)..........................................................................................259

    9.4.1 Objetivo ..........................................................................................................................................................2599.4.2 Descripcin del Transductor de la Barra Pulida..............................................................................................2609.4.3 Adquisicin de Datos con PRT.......................................................................................................................2618.5.4 Instalacin y Calibracin ...............................................................................................................................2639.4.4.1- Procesamiento Automtico.........................................................................................................................268

    9.5 Prueba de VlvulaS Fija y Viajera..............................................................................................................................2749.5.1 Fugas del Pistn y Vlvula Viajera. (TV test).....................................................................................................2769.5.2 Prueba de la Vlvula Fija (SV) .......................................................................................................................276

    9.5.2.1 Prueba de Vlvula Fija (SV) Usando Celda PRT ........................................................................................2778.5.7 Prueba del Efecto de las Contrapesas..............................................................................................................2799.7 Recordando Registros Dinamomtricos.............................................................................................................282

    9.8 Graficas auxiliares para analysis dinamometrico.......................................................................................................28410.0 MEDICIN DEL AMPERAJE DEL MOTOR........................................................................................................287

    10.1 Seguridad Elctrica ..............................................................................................................................................28810.2 Instalacin del Medidor de Corriente del Motor ..................................................................................................288

    10.2.1 Acceso a la Caja del Interruptor....................................................................................................................28910.2.2 Instalacin del Sensor de Corriente...............................................................................................................289

    11.0 - MEDICIN DE LA POTENCIA DEL MOTOR...................................................................................................29011.1 Seguridad Elctrica ..............................................................................................................................................29010.2 Instalacin del Sensor de Potencia .......................................................................................................................290

    Sensores de Potencia Elctrica Modelo 200 ............................................................................................................29011.2.1 Uso del Equipo de Proteccin.......................................................................................................................29311.2.2 Acceso a la caja del Interruptor.....................................................................................................................29311.2.3 Instalacin del Sensor de Corriente...............................................................................................................29411.2.4 Instalacin de los Medidores de Voltaje .......................................................................................................295

    11.3 Procedimiento de Medicin..................................................................................................................................29611.3.1 Comienzo de la Adquisicin de Datos ..........................................................................................................29611.3.2 Adquisicin de Datos de Potencia.................................................................................................................29711.3.3 Control de Calidad de los Datos ...................................................................................................................299

    11.4 Anlisis de Datos de Torque y Potencia...............................................................................................................30011.4.1 Eficiencia y Consumo de Energa.................................................................................................................301

    11.4.1.1 Definicin de los Parmetros del Desempeo del Motor ......................................................................30111.4.1.2 Carga del Motor.....................................................................................................................................302

    11.4.2 Anlisis de la Curva de Torque.....................................................................................................................30311.5 Balanceo de la Unidad de Bombeo ......................................................................................................................305

    11.5.1 Identificacin de las Contrapesas..................................................................................................................30511.5.2 Ajuste de la Posicin de las Contrapesas ......................................................................................................30611.5.3 Revisin de Resultados .................................................................................................................................306

    11.6 Mediciones Especiales .........................................................................................................................................30712.0 FUNCIONES AUXILIARES...................................................................................................................................308

    12.1 Impresin de Reportes y Exportacin de Datos de Registros..............................................................................30812.1.2 Copia y Transferencia de Graficas o Datos...................................................................................................30812.1.3 Impresin de Reportes por Lotes ..................................................................................................................30912.1.4 Exportando datos ..........................................................................................................................................314

    12.2 Prueba del Equipo Electrnico y Cables (Modelo E3) .........................................................................................32412.2.1 Probando el Equipo desde la Pantalla de Revisar Equipo .............................................................................325

    12.3 Asistente para diagnstico de problemas en el equipo (Modelo E3)....................................................................327

  • 7/30/2019 Manual Twm 2009

    7/353

    DRAFT - Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 24/04/20097

    12.3.1 Chequeo del Voltaje de la Batera ................................................................................................................32912.3.2 Chequeo de Amplificadores y Cables...........................................................................................................32912.3.3 Chequeo del Canal del Microfono (Acoustic channel Test Output) .............................................................33112.3.4 Chequeo de los Cables de Sensores, Amplificadores y Convertidor A/D ....................................................333

    12.4 Chequeo Electrnico para los Modelos E1 y E2 .................................................................................................33412.4.1 Chequeo Usando el Modulo Equipment Check ............................................................................................33412.4.3 Revisin del Cable Serial..............................................................................................................................33612.5 Modalidad Experta de Deteccin de Fallas (Modelos E1 y E2) ......................................................................339

    12.5.1 Revisin del Voltaje .................................................................................................................................33912.5.2 Revisin de los Sensores ..........................................................................................................................33912.5.3 Revisin de los Amplificadores................................................................................................................34012.5.4 Chequeo Cable y Amplificador de Micrfono .........................................................................................34112.5.5 Revisin de Cables, Amplificadores y Convertidor A/D..........................................................................342

    APNDICE I Velocidad del sonido en gases con mezclas de hidrocarburos en FUNCIN de PRESIN y temperatura 1APPENDIX II PISTOLA DE GAS DE 5000PSI, IMPLOSION/EXPLOSION OPERACIN MANUAL DEL

    SUPLEMENTO..............................................................................................................................................................................3A - SEGURIDAD ........................................................................................................................................................ 3B - OPERACIN GENERAL DE LA PISTOLA EN MODO IMPLOSIN .............................................................3

    B1- TECNICAS DE OPERACIN MODO IMPLOSIN...................................................................................3C - OPERACIN GENERAL DE LA PISTOLA EN MODO EXPLOSIN.............................................................4C1 - TECNICAS DE OPERACIN MODO EXPLOSIN .................................................................................4

    D DESCRIPCIN GENERAL MODELO VIEJO DE LA PISTOLA DE GAS DE 5000 PSI.............................5 D1 TECNICAS DE OPERACIN MODO IMPLOSIN................................................................................. 6D2 - TECNICAS DE OPERACIN MODO EXPLOSIN .................................................................................6

    E MODIFICACIN DEL CONECTOR DE LA VVULA....................................................................................7F MANTENIMIENTO PREVENTIVO ...................................................................................................................8G INSTALACIN DE LA PISTOLA DE GAS DE 5000 PSI PARA ADQUIRIR DATOS ACSTICOS ...........8

    APPENDIX III CHEQUEO DE LA RESPOESTA DEL MICROFONO...................................................................10APPENDIX IV CURVAS TIPICAS DE DESEMPEO PARA MOTORES DE A GAS ARROW .........................11

  • 7/30/2019 Manual Twm 2009

    8/353

    Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 8 24/04/2009

    INTRODUCCIN

    Seguridad

    Por favor observe todas las normas de seguridad para operar este equipo. Las presiones nominales de la pistola de gasEchometer Co. y de todas las uniones, mangueras, etc. deben ser siempre mayores que la presin del pozo. Debido a que la

    presin del revestimiento (casing) siempre incrementa durante una prueba de restauracin, ciertas precauciones se deben tener encuenta para que la presin del pozo no sobrepase las presiones nominales del equipo.

    No use partes corrodas o desgastadas. Un accesorio corrodo o desgastado puede no resistir las presiones nominalesoriginales del equipo.

    No todas las precauciones de seguridad se dan en este documento. Por favor refirase a los manuales de seguridad,boletines, etc. que estn relacionados con manejo de presiones, caractersticas de los materiales, efectos de temperatura, corrosin,desgaste de materiales, propiedades elctricas, propiedades de los gases, etc. antes de operar este equipo.

    Las pruebas no se deben ejecutar si el usuario, el equipo y el pozo no estn en condiciones seguras de operacin. Esteequipo no se debe usar si el operador esta cansado, enfermo o bajo la influencia de alcohol, drogas o medicamentos.

    Como Usar este Manual

    Este es un manual general que abarca todas las utilidades de los programas Analizador de Pozo y AdministracinCompleta de Pozo (TWM). Como algunos usuarios pueden estar solamente interesados en algunos temas del equipo, el manualesta dividido en ocho secciones principales, las cuales se pueden leer independientemente.

    1. Generalidades del Sistema Analizador de Pozo (Captulos 1, 2 y 3).2. Estudio Acstico del Pozo (Captulos 4 y 5).3. Pruebas Transientes de Presin (Captulo 6).4. Seguimiento del Nivel de Lquido (Captulo 7).5. Pruebas del Dinammetro (Captulo 8).6. Medida de la Corriente y Potencia del Motor (Captulos 9 y 10).7. Programas Auxiliares y Problemas ms Comunes (Captulos 11 y 12).8. Publicaciones Tcnicas (Apndice).

    Si ya est familiarizado con el Analizador de Pozo puede omitir la seccin 1 y pasar a la seccin que le interese.

    Si no est familiarizado con el Analizador de Pozo, por favor primero lea la seccin 1. La publicacin AdministracinCompleta de Pozo que esta en el apndice presenta una revisin de como el sistema puede ser utilizado para optimizar eldesempeo de los pozos de bombeo.

    Organizacin de los Temas

    Dentro de cada seccin la informacin se organiza de la siguiente manera:

    Primero se describe el equipo y los programas del Analizador de Pozo que se requieren para determinadaaplicacin.

    Luego, se dan instrucciones detalladas para el uso del programa. Con ejemplos de campo se ilustran las aplicaciones ms cotidianas. Cuando sea necesario, se presentan guas para resolver los problemas ms comunes. Se discuten la operacin y los procedimientos de mantenimiento del equipo.

  • 7/30/2019 Manual Twm 2009

    9/353

    Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 9 24/04/2009

    1. OBJETIVOS DEL ANALIZADOR DE POZO

    El objetivo principal del Analizador de Pozo es proveer al operador todos los datos necesarios para analizar eldesempeo de un pozo de gas o de petrleo. Este objetivo se logra usando combinaciones de equipos y programas de computadorlos cuales son especficos para cada medida que se vaya a realizar. La configuracin ms general del Sistema Analizador de Pozose presenta el diagrama de bloque que se muestra en la Figura 1.

    La aplicacin e interpretacin de las medidas que se hacen con el Analizador de Pozo pueden dar respuestas a numerosaspreguntas relacionadas con la produccin de los pozos de bombeo. La siguiente es una lista de algunas de las preguntas que sepueden responder con el uso y con la interpretacin adecuada de las mediciones del Analizador.

    A partir de las medidas acsticas en el pozo:

    Hay lquido por encima de la bomba? A qu profundidad est el tope de la columna de lquido? Est el gas fluyendo por el anular? En caso afirmativo a que tasa?

    Cul es la presin de cabeza del revestimiento (casing)? Est variando con el tiempo? Cul es el porcentaje de lquido de columna de fluido en el anular? Cul es la presin en las perforaciones? Cul es el porcentaje de la tasa mxima de petrleo que est siendo producida? Cul es la tasa mxima que puede ser producida por el pozo? Cul es la velocidad del sonido en el anular con gas? Cul es la gravedad especfica promedio del gas en el anular? Hay alguna restriccin o anomala en el anular por encima del nivel del lquido?

  • 7/30/2019 Manual Twm 2009

    10/353

    Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 10 24/04/2009

    Diagrama de Bloques del Sistema Analizador de Pozo

    A partir de las medidas del dinammetro:

    Est el pozo bombeando con la bomba vaca (pumped off)? Cul es el porcentaje de llenado de la bomba? Estn las vlvulas fija y/o viajera con fugas? Cul es el desplazamiento de la bomba en barriles por da? Cul es el desplazamiento efectivo del pistn de la bomba? Cul es la velocidad de bombeo? Cul es la carga de fluido en la bomba? Estn las cargas mximas y mnimas en la barra pulida dentro de la capacidad de la unidad de bombeo y de las

    varillas? Cuntos Caballos de Fuerza tiene la barra pulida? Es el torque mximo, menor que el de la caja reductora? Est la unidad bien balanceada? Qu cambio requieren las contrapesas para balancear la unidad? Cul es el peso de las varillas en el fluido? Requiere todo el sistema de bombeo un anlisis detallado y/o rediseo?

    A partir del estudio de la corriente del motor:

    Cul es la corriente del motor durante el ciclo de bombeo? Es o no el tamao del motor suficiente para la unidad y la carga?

    Est la unidad bien balanceada?

  • 7/30/2019 Manual Twm 2009

    11/353

    Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 11 24/04/2009

    Requiere el desempeo del motor un anlisis ms detallado?

    A partir del estudio del seguimiento del nivel de lquido:

    Cul es la profundidad del nivel del lquido? Est el nivel del lquido aumentando o disminuyendo? Est el nivel del lquido dentro del intervalo esperado?

    A partir del estudio potencia/corriente del motor:

    Cul es la potencia usada durante una carrera de la bomba? Cul es la corriente aparente del motor? Est el motor generando electricidad en algn momento de la carrera? Cul es el consumo exacto de potencia, kwh/day, $/mes, $/bbl? Es o no el tamao del motor suficiente para la unidad y la carga? Cul es el torque? Est la unidad bien balanceada?

    Que cambios requieren las contrapesas para balancear la unidad? Cul es el tamao mnimo del motor recomendado?

    A partir del estudio de presiones transientes:

    Cul es un buen estimado de la presin del yacimiento? Cul es la presin dinmica de fondo del pozo? Cul es la tasa de restauracin de presin? Hay flujo de lquido/gas en el anular cuando el pozo se cierra? Hay algn dao de formacin? Esta la formacin fracturada? Requiere el pozo un anlisis detallado de presiones transientes?

    A partir de estudios particulares:

    En pozos con levantamiento artificial de gas (gas lift), en dnde esta el nivel de fluido en el anular? Cuantas vlvulas de levantamiento artificial (gas lift) estn por encima del nivel del lquido? En un pozo de gas que esta cerrado, en donde esta el nivel de fluido dentro de la tubera de produccin? En un pozo que esta cerrado, cul es la presin del yacimiento? Cul es el estado (abierta o cerrada) de la vlvula de seguridad de subsuelo? Cul es la posicin del colchn del lquido en un tratamiento por baches? Cul es la presin de restauracin en pozos fluyendo? Calibracin de los transductores de presin de fondo de la bomba electrosumergible.

    Las siguientes secciones de este manual explican en detalle como el Analizador de Pozo se puede usar para resolver la mayora delos problemas encontrados cuando se trata de optimizar el desempeo del pozo y de minimizar los costos operativos. Se

    recomienda que el operador se familiarice con el material del manual antes de operar el equipo.

  • 7/30/2019 Manual Twm 2009

    12/353

    Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 12 24/04/2009

    2. GENERALIDADES DE LAS APLICACIONES DEL ANALIZADOR DEPOZO

    A continuacin se explica la tecnologa que ha dado como resultado el desarrollo del Analizador de Pozo y se presentauna breve descripcin de las medidas que se pueden realizar.

    2.1 Registros Acsticos en Pozos

    Las tcnicas acsticas (echo-ranging) para realizar sondeos en pozos han ayudado, por ms de cincuenta aos, en losanlisis de pozos de bombeo1. Anteriormente las aplicaciones se limitaban a determinar la presencia de lquido en el anular porencima de la bomba. Si se encontraba lquido por encima de la bomba, el operador poda tratar de aumentar la produccin alinstalar una bomba mas grande, o si la bomba no estaba operando apropiadamente esta deba ser retirada y reparada.

    Posteriormente con el desarrollo de estos instrumentos, algunos operadores se dieron cuenta que con una interpretacinadecuada de los registros se poda obtener informacin adicional. En particular, la presin de fondo del pozo se calcula, sumandola presin de superficie del revestimiento (casing) y las presiones de la columna hidrosttica de gas/lquido. Esto necesita conocerla densidad y distribucin del petrleo y agua en la columna del lquido, especialmente en el caso de pozos cerrados dondecolumnas de lquidos relativamente altas se observan. Los operadores tambin observaron que en los casos en donde el gas seventeaba por el anular, la presin de fondo de pozo calculada era excesivamente alta. Esto se atribua a la disminucin delgradiente efectivo de lquido por la presencia de burbujas de gas en la columna del lquido por encima de las perforaciones. C. P.Walker2 patent un mtodo para determinar la densidad de columnas lquidas en el anular las cuales estn aireadas por burbujasde gas que fluyen hacia arriba a travs del lquido. Walker present una tcnica en donde una vlvula de contrapresin se usa paracontrolar e incrementar la presin de cabeza del revestimiento (casing) haciendo que el nivel de lquido del anular disminuya unadistancia correspondiente al incremento de presin. El gradiente del lquido gaseoso se calcula dividiendo los cambios de presinen el tope de la columna lquido gaseosa por la correspondiente cada en el nivel del lquido. Este gradiente posteriormente se usa

    para calcular la presin de fondo del pozo. Si el ajuste de la vlvula de contrapresin se incrementa hasta que el tope de lacolumna lquido gaseosa se estabiliza en la vecindad de la entrada de la bomba, la cual esta cercana a las perforaciones, entonces

    la presin de fondo dinmica del pozo se puede estimar con mas precisin ya que la contribucin de la presin hidrosttica de unapequea columna lquido gaseosa es pequea con relacin a la presin de cabeza del revestimiento (casing), y los errores en elgradiente estimado no afectarn significantemente la presin total resultante. En la mayora de los pozos de produccin enEstados Unidos, el nivel de lquido esta cerca a la entrada de la bomba y la presin en la cabeza del revestimiento (casing) mas la

    presin hidrosttica del gas dan un muy buen estimativo de la presin dinmica de fondo de pozo. Este mtodo que se presenthace ms de cincuenta aos, es aun el mtodo mas usado para obtener con precisin las presiones dinmicas de fondo de los

    pozos.Los estudios por McCoy, y otros3, presentan una tcnica para obtener la tasa de flujo de gas en el anular midiendo la tasa

    de aumento de presin del gas en el anular cuando este se cierra. Para efectuar la medida del nivel de lquido. Utilizando la tasa derestauracin de presin del gas en el anular y el volumen del espacio anular, la tasa de flujo de gas en el anular se puede obtenercon exactitud. Si la tasa de flujo de gas en el anular se conoce, un estimativo del gradiente de la columna del lquido se obtieneusando una correlacin desarrollada con datos de campo. Esto calcula una presin dinmica de fondo del pozo con una exactitudrazonable aun cuando haya una columna de lquido gaseoso por encima de la bomba. Adicionalmente a la tasa de flujo de gas en

    el anular, el operador tambin puede calcular la gravedad especfica del gas si se hace un sondeo acstico de pozo ya que lavelocidad acstica y la presin se conocen y la temperatura se puede estimar. El clculo de la gravedad especfica del gas permiteun clculo ms exacto de la presin de la columna de gas.

    Con el uso de computadores porttiles el operador puede automticamente obtener datos acsticos del nivel de lquido ymedidas de presin en superficie con los cuales se pueden calcular las presiones de fondo del pozo. Por lo tanto, pruebas derestauracin/cada de presin en pozos de bombeo se pueden hacer a bajos costos. Los datos de presiones de restauracin le

    1Walker, C. P., "Determination of Fluid Level in Oil Wells by the Pressure-wave Echo Method," AIME Transactions,1937, pp. 32-43.

    2Walker, C. P., "Method of Determining Fluid Density, Fluid Pressure, and the Production Capacity of Oil Wells, US.Patent No. 2,161,733 filed October 26, 1937.

    3McCoy, J. N., Podio, A. L. and K. L. Huddleston: "Acoustic Determination of Producing Bottomhole Pressure," SPEFormation Evaluation, September 1988, pp. 617-621.

  • 7/30/2019 Manual Twm 2009

    13/353

    Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 13 24/04/2009

    permiten al operador obtener propiedades del yacimiento como permeabilidad, dao de formacin, presiones de yacimiento yotros parmetros a un costo relativamente bajo.

    Con el uso de un computador porttil se obtienen cuatro importantes ventajas. Primero, el computador puede utilizar unprocesamiento digital de los datos acsticos para obtener automticamente profundidades de niveles de lquido ms exactas.

    Segundo, se obtienen automticamente el clculo de las presiones de fondo de pozo a partir de las medidas acsticas de nivel delquido, la presin de superficie y las propiedades de los fluidos producidos. Tercero, el computador ofrece una operacinautomtica del equipo debido a que este se puede programar para realizar sondeos y as obtener medidas de presin delrevestimiento (casing) automticamente, sin la presencia del operador. Cuarto, los datos del pozo se pueden almacenar yadministrar exacta y eficientemente. Esto permite: anlisis del desempeo de los pozos, anlisis de presiones transientes yobtencin del desempeo del bombeo, todo al mismo tiempo.

    2.2 Estudios con el Dinammetro

    El bombeo mecnico sigue siendo el mtodo de levantamiento artificial mas usado. Las condiciones econmicasestablecen que se mantengan las mximas eficiencias en estas instalaciones en todo momento. Los mtodos para analizar eldesempeo del sistema de bombeo mecnico se basan en el desarrollo del dinammetro realizado por Gilbert4 y Fagg5 en donde lacarga en la barra pulida se registra grficamente en funcin de su posicin para generar una grfica que representa el trabajohecho en superficie por la unidad de bombeo mecnico para cada carrera de la bomba.

    Los desarrollos recientes se han concentrado en refinar las tcnicas de interpretacin de las caractersticas de esta curvade carga-desplazamiento para lograr un anlisis detallado del sistema, entre los cuales se mencionan:

    Distribucin de la carga en la sarta de varillas. Carga y desplazamiento en la bomba. Operacin y fuga de las vlvulas de la bomba. Torque y eficiencia de contrabalanceo. Carga de fatiga y colapso de varillas. Desempeo del motor.

    Con el desarrollo de sistemas de adquisicin de datos digitales de alto desempeo, se ha dado ms atencin a anlisisms completos del desempeo de la unidad de bombeo mecnico. Las mediciones simultneas de diversos parmetros dinmicos(kilovatios de entrada, factor de potencia, torque del motor, torque de la caja reductora, posicin de la barra pulida, velocidad,aceleracin y carga, velocidad del motor y carreras por minuto de la unidad) son posibles y econmicamente efectivas.

    El Analizador de Pozo permite la adquisicin de datos desde los transductores de carga y de aceleracin con la finalidadde obtener anlisis simples o avanzados del dinammetro. El operador puede seleccionar esta modalidad desde el men principaldel Analizador entrando la opcin deseada y entrando la informacin necesaria de acuerdo a las caractersticas de lostransductores que se usaran.

    El Analizador provee facilidades para adquirir y mostrar los datos del dinammetro y para grabar la informacin en undisco de memoria para un procesamiento y anlisis posterior.

    2.3 Anlisis del Balanceo de la Unidad de Bombeo Mecnico y del Torque

    Un contrabalanceo apropiado de los vstagos es importante, pues este tiene un efecto directo en los costos de operacin ymantenimiento de la unidad de bombeo mecnico. Un contrabalanceo apropiado, significa una operacin mas suave de la unidadde bombeo, reduccin de la variacin de la carga y la velocidad, reduccin en la variacin del torque de la caja reductora,reduccin de esfuerzos de las varillas y un incremento de las carreras por minuto (spm).

    El anlisis del torque es el primer paso en el clculo del contrabalanceo. Los clculos a partir de las medidas deldinammetro requieren medidas del efecto del contrapeso transmitido a la barra pulida. Esto es en funcin de la posicin de las

    4Gilbert, W.E., "An Oil Well Pumping Dynagraph," API Drilling and Production Practice, 1936, pp. 94-1155Fagg, l. W., "Dynamometer Charts and Well Weighing," Petroleum Transactions, AIME, Vol. 189, 1950, pp. 165-174.

  • 7/30/2019 Manual Twm 2009

    14/353

    Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 14 24/04/2009

    contrapesas en las manivelas y de la geometra de la unidad de bombeo. El efecto del contrabalanceo se puede medir directamenteusando el dinammetro. La geometra de la unidad de bombeo se puede determinar a partir de la medida de las dimensiones de loselementos principales, o en general, se pueden obtener desde la base de datos de las unidades de bombeo estndar. El balanceo seobtiene midiendo la posicin de las contrapesas en las manivelas, identificando las manivelas y calculando el cambio delmomento del contrabalanceo correspondiente al cambio en la posicin de las contrapesas.

    Los datos del dinammetro, que consiste en la carga de la barra pulida en funcin de la posicin, se convierte a torqueneto en funcin del ngulo de las manivelas. La funcin de torque resultante se examina en trminos del torque durante la carreraascendente y durante la carrera descendente. Un balanceo se considera apropiado cuando el torque se iguala, de tal forma que eltorque mximo en la carrera ascendente es aproximadamente igual al torque mximo de la carrera descendente. Una vez que lacurva de torque se obtiene, es posible calcular el efecto del cambio de posicin de las contrapesas en el torque. As, el programada una recomendacin en cuanto a cmo se va a desempear la unidad, si es que esta ha sido apropiadamente balanceada.

    Siendo que la mayora de las unidades de bombeo se operan con motores elctricos, el contrabalanceo se puede obtenercon las medidas de la corriente del motor. Esto se logra debido a que hay una relacin directa pero no lineal entre la corriente delmotor y el torque del motor.

    Sin embargo, se debe tener en cuenta que usualmente los medidores de corriente elctrica no diferencian la direccin del

    flujo de la corriente. En muchas instalaciones de unidades de bombeo mecnico, la carga cclica impuesta a la bomba (la carga delas varillas se incrementa al peso de las varillas en el fluido mas la carga del fluido y luego disminuye al peso de las varillas en elfluido) es tal que durante ciertos trayectos de la carrera, el motor es accionado por la unidad de bombeo. En este momento elmotor acta como un generador y la corriente fluye inversamente. El medidor de corriente indicar la corriente generada sinindicar la direccin de flujo. Esto puede enmascarar los picos de corriente que corresponde al torque mximo dificultando el

    balanceo de la unidad al usar la medicin de corriente estndar.

    El Programa de Estudio de la Corriente del Motor de Echometer Co., descrito en la seccin 9 de este manual, proveeformas para determinar con exactitud la magnitud y la direccin del flujo de la corriente en cada una de las lneas trifsicas.

    El Programa de Estudio de la Potencia del Motor de Echometer Co., descrito en la seccin 10 de este manual, proveeformas para determinar con exactitud la potencia usada y el flujo de corriente del motor durante una carrera de la bomba. Losdatos de potencia tambin se interpretan en trminos del torque de la caja reductora. El programa da informacin de cmo ajustar

    las contrapesas para obtener una condicin balanceada. Esto no requiere un conocimiento de la geometra de la unidad ni unaidentificacin de las manivelas. El operador necesita solamente entrar el peso de las contrapesas que l desea mover. El programacalcula la distancia que las contrapesas necesitan ser movidas desde su posicin actual.

    2.4 Pruebas de Presin Transitoria

    Los estudios de presin dinmica de fondo, pruebas de restauracin de presin y pruebas de cadas de presin son lasprincipales herramientas para determinar la presin del yacimiento, la permeabilidad de la formacin y el factor de dao. Estastcnicas se usan ampliamente en pozos fluyentes y en algunos pozos de levantamiento artificial de gas, en donde la informacinde la presin se obtiene fcilmente usando registradores de presin bajados con cable dentro del pozo. La presencia de las varillasen los pozos de bombeo mecnico impide la prctica de mediciones directas de presiones de fondo de pozo rutinarias, eliminandoel parmetro ms importante para analizar el desempeo del pozo. Las instalaciones permanentes en superficie que registran la

    presin de fondo de pozo no han presentado ventajas econmicas ni tampoco realizan mediciones a travs del espacio anular.

    El Sistema Acstico Automtico de Presin Transitoria se basa en el Analizador de Pozo Digital configurado para unaoperacin larga que no necesita ser monitoreada continuamente. Esto se logra usando una fuente de potencia y de gas de largaduracin y cambiando a un programa desarrollado especialmente para grabar y analizar datos de presin transitoria. El mduloespecial del programa TWM, Anlisis y Adquisicin de Datos de Presin Transitoria, tiene mltiples funciones de control de lasecuencia de las pruebas del pozo, adquiriendo, grabando y analizando los datos y generando tablas y grficas para presentar losresultados.

    Los clculos de presin de fondo se basan en la medida de la presin en cabeza, en las profundidades de la interfacegas/lquido y en los clculos de los gradientes de los fluidos en el anular. Para obtener con mayor exactitud los clculos de la

    presin de fondo de pozo, el Programa Analizador de Pozo tiene en cuenta las variaciones de temperatura y las variaciones de lavelocidad acstica debido a los cambios en la composicin del fluido del anular que se originan por las variaciones de presin

    durante la prueba transitoria.

  • 7/30/2019 Manual Twm 2009

    15/353

    Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 15 24/04/2009

    Durante los das de duracin de una prueba de pozo comn, el elemento sensitivo del transductor puede experimentarcambios de temperatura mayores a 60 F. Aunque el transductor se compensa por si solo por temperatura, los cambios detemperatura pueden originar pequeos errores en la medida de la presin en la cabeza del revestimiento (casing) lo cual serainaceptable para los anlisis de presin transitoria. Correcciones adicionales se introducen midiendo la temperatura con una

    resistencia trmica y calculando la desviacin de presin correspondiente a partir de curvas de calibracin obtenidas para cadatransductor y entradas al programa.

    Durante una prueba de pozo (restauracin o cada), la presin, la temperatura y la composicin del gas en el anularpueden manifestar cambios significativos. Esto puede originar variaciones en la velocidad acstica del gas. En un momentodeterminado la velocidad acstica promedio se calcula con una cuenta automtica de las reflexiones de las uniones y con el

    promedio de la longitud de los tubos. Una tabla de la velocidad acstica en funcin del tiempo se genera para cada secuencia de laprueba y se almacena con los datos de presin. El programa de reduccin de los datos interpola entre estos puntos para calcular laprofundidad de la interface gas/lquido a partir de la medida del tiempo de trnsito del eco del lquido. Si esta variacin no setiene en cuenta y si solo se usa un valor de velocidad acstica para interpretar los datos de tiempo de viaje, un error significativose obtendra al calcular la presin de fondo de pozo.

    Muchos documentos se han presentado acerca de los mtodos para el clculo de la presin de fondo de pozo a partir del

    nivel del lquido en el anular determinado acsticamente6

    . La presin de fondo de pozo es la suma de la presin de cabeza delrevestimiento (casing) y las presiones de la columna hidrosttica debidas al lquido y al gas en el anular. El gradiente de lacolumna del gas se calcula en funcin de la presin, temperatura y gravedad del gas. El gradiente de la columna del fluido en elanular es una funcin de la composicin de los lquidos y de la razn de agua/petrleo y gas/lquido in situ. Las condiciones de

    bombeo y la geometra del pozo determinan las distribuciones del fluido. Por ejemplo, a una tasa de bombeo en estado estable ellquido por encima de la entrada de la bomba es petrleo debido a la segregacin por gravedad que ocurre en el anular. Cuando el

    pozo se cierra para una prueba de restauracin, el corte de agua se mantiene esencialmente constante durante el perodo posterioral flujo. Estos factores se consideran en el programa para el clculo de la presin de fondo del pozo. Las densidades in situ del

    petrleo y del agua se calculan en funcin de la presin y de la temperatura, usando correlaciones convencionales.

    Cuando la presin dinmica de fondo del pozo est por debajo del punto de burbuja, se produce gas libre en elyacimiento y generalmente estos gases se producen por el anular. Esta produccin de gas libre del anular reduce el gradiente de lacolumna del lquido y por lo tanto debe ser tenida en cuenta para el clculo de la presin de fondo del pozo. La experiencia indica

    que una columna lquido gaseosa se puede extender por un perodo de tiempo significativo despus de que el pozo se ha cerrado.Una correlacin obtenida a partir de muchas mediciones de campo de gradientes de columnas lquido gaseoso 7 se usa para teneren cuenta este efecto. Sin embargo, cuando una columna lquido gaseosa alta se presenta, para obtener resultados ms precisos, serecomienda que antes de iniciar la prueba de restauracin el nivel de lquido se debe disminuir hasta unas pocas uniones porencima de la bomba incrementando la contra presin en la cabeza del revestimiento (casing) y a la vez manteniendo una tasa de

    bombeo estable. Esto se logra fcilmente utilizando un regulador de contra presin ajustable que se instala en la vlvula de lacabeza del revestimiento (casing). Es muy importante que el pozo este estabilizado antes de comenzar la prueba de presintransitoria.

    2.5 Monitoreo del Nivel del Lquido

    La posicin del nivel del lquido en el anular es un indicador importante de la condicin de balance de la presin del

    pozo. Particularmente, es muy importante durante los trabajos de reacondicionamiento del pozo en el momento en que el rbol denavidad no est instalado y durante los procedimientos para matar el pozo cuando el estado de presin del pozo debe ser asumido.El Analizador de Pozo se puede usar en la modalidad de registro continuo para medir y seguir automticamente la posicin delnivel del fluido en el anular.

    6 Vea las referencias de los artculos tcnicos en el apndice7

    McCoy et al. 1988.

  • 7/30/2019 Manual Twm 2009

    16/353

    Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 16 24/04/2009

    2.5.1 Operaciones para Matar el Pozo y para Reacondicionamiento

    Cuando se necesita matar un pozo, antes de hacer cualquier trabajo de reacondicionamiento, es necesario determinar la

    mnima cantidad de fluido que se debe usar en el pozo para matarlo. Presiones del pozo muy superiores a la presin de formacinoriginan grandes daos de formacin y costos excesivos. Un inadecuado balance de presiones puede originar un reventn delpozo. Monitoreando continuamente el nivel del fluido en el anular para matar el pozo es posible mantener un control de lacontrapresin en la formacin. El mdulo de Seguimiento del Lquido (Liquid Tracking) enva automticamente pulsos acsticosa intervalos determinados de tiempo tan frecuente como dos minutos, calcula la profundidad y muestra la posicin del nivel dellquido en funcin del tiempo. Una alarma suena si el nivel de lquido incrementa por encima o disminuye por debajo delintervalo de la profundidad predeterminada. El programa tambin puede cerrar un interruptor de rel que se puede conectar alsistema de alarma del equipo de reacondicionamiento.

    2.5.2 Monitoreo del Tratamiento por Baches

    Normalmente se usan inyecciones peridicas de qumicos al pozo en trabajos de reparacin como remedio para eldepsito de parafinas, la inhibicin de corrosin y limpieza de las perforaciones. El mdulo LT provee un mtodo sencillo para

    monitorear la posicin del fluido durante el tratamiento por baches. El descenso del fluido de tratamiento se puede observarmonitoreando la posicin de la interface gas/lquido en funcin del tiempo.

    2.6 Pruebas Especiales

    Los registros de las medidas del eco se han desarrollado en primera instancia para los anlisis y la optimizacin delbombeo mecnico. Los avances en los computadores porttiles han hecho posible el uso efectivo de las medidas del eco en otrasaplicaciones, las cuales involucran la determinacin de la distribucin de los fluidos y de las presiones en el pozo.

    2.6.1 Levantamiento Artificial Neumtico (Gas lift)

    La aplicacin ms comn es la determinacin del fluido en el anular con respecto a la profundidad de las vlvulas de

    descarga. Esto permite monitorear el proceso de la operacin de descarga y determinar cundo y si la vlvula ha sido descubiertay est inyectando gas en la tubera de produccin. Las medidas se pueden interpretar en trminos de la presin dinmica de fondode pozo utilizando el procedimiento presentado por McCoy8.

    2.6.2 Prueba de la Vlvula de Seguridad del Subsuelo

    En instalaciones de costa afuera es necesario que peridicamente se revise el funcionamiento de las vlvulas deseguridad del subsuelo controladas desde superficie (SCSSV). Este chequeo usualmente se hace cerrando el pozo en el arbol denavidad, permitiendo que la presin se restaure y estabilice, luego cerrando la SCSSV, posteriormente se despresuriza la seccinde tubera por encima de la SCSSV. Es comn que la vlvula no cierre completamente debido a la presencia de arena o de

    partculas slidas o debido a la corrosin. Generalmente, la interface gas/lquido en la tubera se estabiliza por debajo de laSCSSV. Por lo tanto, un registro de medidas de ecos dar una indicacin de que la vlvula ha operado apropiadamente y si hacerrado antes de despresurizar la seccin de la tubera. Esto puede ahorrar bastante tiempo siendo que es posible hacer actuar la

    vlvula varias veces hasta que esta opere apropiadamente. Si esto no se logra entonces se debe decidir sacar la vlvula lo mspronto posible y repararla.

    2.6.3 Registros de la Presin de Fondo del Pozo a travs de la Tubera de Produccin

    Registros de las medidas del eco se pueden llevar a cabo a travs de la tubera de produccin como tambin a travs delanular. La profundidad de la interface gas/lquido se puede obtener por medio de diferentes opciones que se encuentran en elAnalizador de Pozo. Cuando la tubera de produccin presenta saltos internos (internal upset), el procesamiento de conteo deuniones automtico es fcil de obtener. En esos casos donde la tubera de produccin es de dimetro interno constante, las otrasopciones de procesamiento son: usar la profundidad de los niples de asiento (landing nipples) o los adaptadores (cross overs), usarla velocidad acstica, etc. proveee la informacin necesaria para llevar a cabo los clculos de la presin de fondo del pozo. Los

    8 McCoy: "Acoustic Determination of Bottomhole Pressure in Gas Lift Wells", Petroleum Engineer International, August1976.

  • 7/30/2019 Manual Twm 2009

    17/353

    Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 17 24/04/2009

    ingenieros de Echometer Co. han acumulado gran experiencia en este tipo de pruebas no convencionales en pozos fluyendo a altapresin. Se dispone de pistolas de gas con rangos de operacin de hasta 15,000 psi. Estas pistolas usan el gas del pozo paragenerar el pulso acstico.

    2.6.4 Desplazamiento de Lquido en la Tubera de Produccin

    Se han obtenido satisfactorios resultados usando las medidas de eco para determinar la posicin del colchn del lquidoque se introduce en el pozo como parte de tratamientos con inhibidores de corrosin, disolventes de parafinas u otros tratamientos

    por baches.

    2.6.5 Bombeo Neumtico Con Pistn

    Los mdulosAcoustic Fluid Level y Plunger Liftse usan para determinar la posicin del pistn, la velocidad de cada delpistn y determinar el comportamiento del pozo.

    Varios artculos que discuten estas aplicaciones han sido publicados y estos se pueden obtener en la pgina web deEchometer.

    2.6.6 Pozos de GasLos mdulosAcoustic Fluid Level y Pressure Transientse usan para determinar la distribucin del fluido en la tubera de

    produccin en un pozo de gas para evaluar el nivel de contrapresin existente debido a acumulacin de lquido al fondo del pozo.Para mayor informacin favor pedir el manual correspondiente.

  • 7/30/2019 Manual Twm 2009

    18/353

    Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 18 24/04/2009

    3. GENERALIDADES ACERCA DE LOS PROGRAMAS USADOS CON ELWell Analyzer

    El Analizador de Pozo se controla por medio del computador porttil. El computador opera desde un programa grabadoen el disco duro. Prenda el computador. Una prueba de memoria comienza automticamente y se muestra en la parte superior dela pantalla. Espere a que la prueba de memoria termine. El programa del analizador de Pozo TWM se cargar automticamente enla memoria. La siguiente seccin asume que su computador tiene un microprocesador 486 o superior, un disco duro y un portadorde discos compactos o de 3 configurado por Echometer Co. que corra en ambiente Windows 95, Windows 98 o Windows NT.

    3.1 Programas

    El Analizador de Pozo se usa en conjunto con varios programas de aplicaciones. Los programas ms comunes son:

    Programas de Adquisicin y Anlisis de Datos

    El programa TWM incluye los siguientes mdulos para adquisicin y anlisis de datos: Registros Acsticos Dinammetro Corriente y Potencia Elctrica Restauracin de Presin Seguimiento de Liquido Bombeo neumtico por pistn

    Programa para el Diseo de la Unidad de Bombeo

    Programa Q-ROD (Programa de la Ecuacin de Onda para el diseo de bombeo mecnico para Windows). El programaQRod es gratis y se puede bajar de la pgina web www.echometer.com e instalar en computadoras que operan en Windows XP oanterior.

    3.1.1 Uso del Teclado y del Ratn

    El programa TWM se ha diseado para ser usado de la manera ms simple posible. La interface grfica sigue todas lasconvenciones de Windows. La mayora de los mdulos se ejecutan siguiendo las instrucciones que se muestran en la pantalla, enel que requiere entrar datos u oprimir una tecla funcin o una combinacin de teclas como Alt-tecla. Las teclas funciones sedisearon para producir resultados similares en las diferentes aplicaciones. El usuario a menudo escoge las acciones desde elmen. Las teclas Tab, Shift Tab, Enter, PageDown, PageUp, flechas, las teclas funciones y Esc se usan generalmente paramoverse dentro de la pantalla o el men y para ejecutar instrucciones. Tambin es posible usar un ratn externo o un apuntador deseguimiento y botones de accin para moverse dentro de la pantalla y escoger las acciones pertinentes. Los detalles se explican enla seccin correspondiente de este manual.

    NOTA: Se recomienda que el usuario siga las instrucciones y las opciones del men que se muestran en cada pantalla.Los programas se escribieron para un sistema completamente compatible con IBM, y el computador en uso podra no sertotalmente compatible con IBM. Los programas se disearon para no ser sensibles a entradas accidentales como oprimir la teclaequivocada o entrar datos invlidos, etc. Sin embargo, puede haber una combinacin extraa de teclas que se oprimen, quecausar que los programas no operen como se espera. En estos casos se recomienda que el computador se apague y el programa sereinicialice.

    El operador determina el flujo del programa seleccionando y operando en el botn de control correspondiente, o con lasteclas funcin o con combinacin de teclas. Las convenciones estndar de Windows se usan para navegar dentro del formatomostrado en la pantalla:

  • 7/30/2019 Manual Twm 2009

    19/353

    Manual de Operacin del Analizador de Pozo y Programa TWM

    ECHOMETER Co. 19 24/04/2009

    Teclas de Funciones

    Presionar una tecla funcin equivale a oprimir el botn que tiene marcado el mismo nmero de la funcin. Por ejemplooprimir la tecla F3 equivale a oprimir el botn Seleccionar Prueba (Select Test) y esto inicia la misma secuencia de eventos.

    Tecla Tab

    Presionar la tecla Tab permite ir a travs de la pantalla y activar los diferentes botones de control o campos haciendoresaltar el que est actualmente activado:

    Una vez un botn est resaltado, este se activa presionando la teclaEnter. Un campo activo se resalta con un fondo azul(o negro) como se muestra en la siguiente figura:

    Tecla Alt

    Presionar la tecla de la letra subrayada en el botn mientras se mantiene presionada la tecla Alt equivale a activar elbotn o campo de control correspondiente. Por ejemplo presionar Alt S es equivalente a oprimir en el botn Salvar (