manejo de balanciadora
-
Upload
jerson-tarazona-alcantara -
Category
Documents
-
view
218 -
download
0
Transcript of manejo de balanciadora
-
7/30/2019 manejo de balanciadora
1/17
LAUNCH KWB-4XX Installation and Parts Manual Safety Precautions
111
-
7/30/2019 manejo de balanciadora
2/17
LAUNCH KWB-4XX Installation and Parts Main Structureee
2
Main Structure
See figure 1
1. Measure scale for automaticmeasurement of the installation distance ofthe wheel and rim diameter, and theaccurate position of the sticking balanceblock.2. Control panel for man-machine dialogue.3. Hanging handle-- For hanging conicalcasing, the wheel width scale and otherspare parts.4. Counterweight groove holder of the
counterweight lead block5. Balance shaft forsupporting the wheel.6. Wheelprotection
The meaning of display panel
Control panel
Counterweightgroove
LAUNCH
Hanginghandle
1
Control Panel
Wheelprotection
Balanceshaft
Measure scale
Fig 1
1. Display for inner side wheel2. Indicating for inner side balance point3. Display for static balance value or rimwidth
4. Indicating for outer side balance point5. Display for outer side wheel6. Indication for balance mode and mm
The meaning of control panel
7. Key (a) used to enter the wheel distancemanually8. Key (b) used to enter the rim widthmanually
9. Key (d) used to enter the rim diametermanually
The control panel of KWB-412 is as shown inFig 2.
-
7/30/2019 manejo de balanciadora
3/17
LAUNCH KWB-4XX Installation and Parts Main Structure
3
Fig2
10. Key for self-diagnosis (LED self-check) and for self-calibration(required to be used with key C)
11. Key for dis-balance recalculation/self-calibration
12. Selection key for inchmm
13. High accuracy balance key14. Dis-balance optimized key15. Key for balance mode selection16. Key for dynamic balance or different
static balance mode selection17. Emergency stop button18. Start button
-
7/30/2019 manejo de balanciadora
4/17
Caution:In order to avoid damaging thefilm of control panel, pleasedont touch the keys with sharp
material.
Composite keys for function conversion
1. [ STOP ] + [ a ] + [ a ]
Conversion keys for the measurement
unit of gram/ounce.First, please press [STOP] button andhold it, thenpress [ a ] and [ a ] at thesame time, the information displayedon the control panel will put out; after
a while, please release button [ a ], [ a ] and [STOP] in turn, theprevious tested data will be redisplayedat once but with another kind of unitsystem.
Note: The different sequence forreleasing the keys may result inthe different data displayed, butit is not necessary for operator to
perform other operations, directlypressing [Start] button is ok.
2. [ STOP ] + [ C ] The keys formeasurement mode selection afterputting down the wheel protection.Please press [STOP] button and hold
it, then press[C] button and hold it; release [ C ]and [ STOP ] button in turn, themeasurement mode will be alternatedbetween Put down the wheelprotection to start measurement andPut down the wheel protection tostart measurement by pressing [START ] button.
3. [ STOP ] + [ FINE ] The keys
for entering the status of measure scale calibration.The self-calibration for measurescale is required to performwhen starting the balancer each
time, otherwise the correctmeasurement status cannot beentered (the detailed informationabout self-calibration will bedescribed later).
-
7/30/2019 manejo de balanciadora
5/17
4. [ D ] + [ C ] The keys foroutside parameter calibration before
measurement.The keys are used to calibrate theCPU memories corresponding to thewheelbase, rim width and rim diameter ofdifferent wheels, so as to ensure themeasurement accuracy (it is necessaryto calibrate inboth Auto mode and Manualmode).
5. [ STOP ] + [ OPT ] Keys fordiameter data adjustment of automeasure scale function.The diameter data of different vehiclewheels can be stored into CPU throughthis operation, and the datacan keep stored even after balancershutdown (the detailed operation will bedesd later).
-
7/30/2019 manejo de balanciadora
6/17
l
Tools
To ensure the smooth installation andadjustment, please get the following toolsready:An adjustable wrench, a set of box wrenches, a pair ofscissors, a set of screwdrivers and a digital multi-meter(measuring voltage).
-
7/30/2019 manejo de balanciadora
7/17
LAUNCH KWB-4XX Installation and Parts Installationn
Installation
Transport
It is advisable to transport themachine with a forklift(Fig. 3)l Pay attention to the barycenter of the
machine. Do not tilt the machine muchduring the moving.
l Do not drive the forklift too fast.l Keep the location of the machine on
the forklift as low as possible.l Do not overturn it during the moving(pay attention to
the position of the barycenter).
Attention:
Fig. 4
Unpacking
Fig.3
Special anti-rust oil applied on the preciseparts may attract dust. Clean it whennecessary.
Positioning
The installation positionmust satisfy the requirementof safe work.l The machine should be installed
close to the main power supply.
l The machine should be installed on theeven concrete floor or other floors withhard surfaces. Adjust the anchor boltstill KWB-4XX is level and stable.(Fig.5). In order to fasten themachine reliably, use oneM1235 fastening bolt to fasten themachine on the floor tightly.Otherwise, it will cause vibrationand noise.
l Enough spaces should be kept foroperation and
maintenance. The space should be notless than 1m at
l Open the packing box according to theInstruction on it.
Remove the packing materials (Fig. 4)and check whether the machine isdamaged during the transportation.Confirm whether the main unit,accessory parts, and relativematerials are all included.
l Keep packing materials away fromchildren. If the packing materials may
cause pollution, please dispose themproperly.
l Remove accessories and spare partssupplied with the machine and place
them on a safe place. Then, removethe cabinet fixed on bottom plate ofpacking box and place them at a safeplace.
-
7/30/2019 manejo de balanciadora
8/17
LAUNCH KWB-4XX Installation and Parts Installationn
front and sides and 0.6m at rear tosatisfy normal operation of themachine.
l If the machine is installed outdoors,
the protective shelter is necessary.l Keep the machine away from flammablegases.
Fig.5
-
7/30/2019 manejo de balanciadora
9/17
Note:
In order to use the machine safely andreasonably, LAUNCH suggests installingthe machine at least 0.6m away fromthe wall.
Installation
Attention:l Please place, move, and store
KWB-4XX in accordance withsafety signs on the package
l Never lift the rotary shaft whenmoving, installing or operating KWB-4XX. Otherwise, the rotary shaft maybe damaged.
Make sure that the machine is stable andin good condition after installation. Theninstall KWB-4XX according to thefollowing Setup Instruction.
Step 1: Installation of thehanging handleTake out the handing handles from theaccessory box (Fig.6) and screw them into the square holeson the left side of the cabinet (Fig. 7)
Fig.6
Fig.7
Step 2: Installation of thecontrol panel
1. Take out the post board from theaccessory box.
Unscrew the four screws on theboard (Fig. 8) and remove the rear
cover of the board.
Fig.8
-
7/30/2019 manejo de balanciadora
10/17
2. Place the post pads between thecabinet and the post panel, and theninstall the post panel on the rear of thecabinet (Fig. 9).
Fig.9
3. Take out the control panel from theaccessory box.
Remove the rear cover of the panel(Fig. 10) and install the control panel onthe top of the post board.
Fig.10
Insert the two cable plugs into theinterfaces on the rear of the computerboard correspondingly (Fig.11). Mountthe rear cover of the control board.
Fig.11
4. Install the rear panel of the post board(Fig. 12).
-
7/30/2019 manejo de balanciadora
11/17
11
Fig.12
Step 3: Installation of the wheel protection1. Unscrew the screws and
nuts on the supporting casing.(Fig. 13).
Fig.13
2. Insert the protective pipe ofthe wheel protection into thesupporting casing. (Fig. 14).Fasten the protective pipe on thesupporting casing by the screwsand nuts. (Fig. 15)
Fig.14
-
7/30/2019 manejo de balanciadora
12/17
444
Fig.15
Step 4: Switch on the machinel Check whether the power supply is in
accordance with the requirements ofthe data plate on the machine
before connection. All connection ofcircuit must be done by professional.l The socket of the power supply
must be installed within the reach ofthe operator. The height should be setat 0.61.7m.
l If the supplied voltage is not stable,please use a voltage regulator.
l The machine must have a goodcabinet ground connection.
Now you have finished the installationof KWB-4XXsuccessfully.
-
7/30/2019 manejo de balanciadora
13/17
LAUNCH KWB-4XX Installation and Parts Manual Calibration and Adjustmenttttt
Calibration andAdjustment
Self-calibration Program of the Balancer
Attention:The self-calibration program should be runafter the equipments first installation or ifthe measurement accuracy of theequipment is suspect, to ensure themeasurementaccuracy of thebalancer.
Turn on the power supply switch of the
balancer, install a wheel with medium size
(13 --15 ), input the data of the
wheel rim and press key atthe same time. The control panel willdisplay the information as shown in Fig 16.
Fig16
Release key, put
down the wheel protection, and press
key to rotate the main-shaft.The control panel will display theinformation as shown inFig 17 when the main-shaftstops rotating.
Fig17
Put down the wheel protection, and attach100g (3.5oz) counterweight on the outsideof the wheel rim. Put down the wheel
protection again, and press key tore-rotate the main-shaft. The control panelwill display the information as shown in Fig18 when the main-shaft stops rotating.
Fig18
The self-calibration is finished, and theself-calibration data is stored in computermemory, which cannot be lost even afterthe balancer shutdown. The wheel balanceoperation
-
7/30/2019 manejo de balanciadora
14/17
LAUNCH KWB-4XX Installation and Parts Manual Calibration and Adjustmenttt
can be performed after above operatingprocedures.
Automatic Measure scale CalibrationProgram
l Automatic Measure scale Distance
Calibration
Press key at the same time,
thecontrol panel will display the information asshown in Fig 19.
Fig19
Move the measure scale to 0 positionand hold it, as shown in Fig 20.
0 Position
Fig20
Press key at the same time, thecontrol panel will display the information asshown in Fig 21.
Fig21
Move the measure scale to 15 positionand hold it, as shown in Fig 22.
15 Position
Fig22
Press key at the same time, thecontrol panel will display the information asshown in Fig 23.
Fig23
-
7/30/2019 manejo de balanciadora
15/17
Move the measure scale to the originalposition, the calibration operation isfinished.
l Automatic Measure scale
Diameter CalibrationInstall a wheel rim with known diameter,and then lock it.
Press key, the controlpanel will display the information as shownin Fig 24.
Fig24
14.0 is the default value. Presskey to input the diameter (10--18 ) of
the wheel rim installed. Press key,the control panel will display the informationas shown in Fig 25.
Fig25
Move the measure scale to the position ofdiameter measurement and hold it, and
then press key at the same time, thecontrol panel will display the information asshown in Fig 26.
Fig26
Reset the measure scale, the calibrationoperation is finished.
Attention:During calibration, if input error occurs,please press [STOP]
key tocancel it.
Self-Testing Program (Testing PositionSensors and Indicators)
Press key, from left to right, theindicators flash one by one, and thecontrol panel will display theinformation as shown in Fig 27.
-
7/30/2019 manejo de balanciadora
16/17
Fig27
The position sensor can be tested at that
moment. Rotate the wheel manually andslowly, indicator ALUI starts flashing, and0 will appear on the right screen when0 position on the main-shaft passesacross the photoelectric sensor as shown inFig 28.
Fig28
Once the wheel turns by one circle, the[0] will appear on right screen one time.When the wheel rotates to the reversedirection, the indicator ALUS will start
flashing. Press key, a number will bedisplayed on the right screen, which is thedistance between the inner side wall of thewheel rim and the balancer cabinet. Whenmoving the measure scale, this number ischanged, too.
Press key, a number will be
displayed on the leftscreen, which is the diameter of thewheel rim. When swaying the measurescale, this number is changed, too. Press
key at current status to
return to the procedure of calibrating thediameter measure scale.
Press key to return to theprocedure of calibrating the width measurescale.
Attenti
on:
The operator can press key to exit
the self-testing
operation atany time.
Adjustment for Sensors and InsideParameters
Sensor
AdjustmentLevel sensor adjustment (Calibrate it afteradjustment each time, and then check it).When the data at the inner side is larger,please move the level sensor to the right.Release the nut at the inner side first, andthen screw the nut at the outsideclockwise; whenthe data at the inner side is smaller, pleasemove the level sensor to the left. Releasethe nut at the outside first, and then screwthe nut at the inner side counterclockwise.
-
7/30/2019 manejo de balanciadora
17/17
Adjustment for Inside Parameters
Press key, the control panelwill display the information as shown in Fig
29.
Fig29
Press key, the screen will be
blackened, and then press key to
enter the adjustment for inside
parameters; press key to switch the insideparameters: AnP, 1.-1, PHA and Pro, etc.1. Adjustment for gram number error
When the displayed data is smallerthan the actual data, please adjustAnP higher (about two times of theerror value); adjust itsmaller contrarily.
2. Keep 1.-1 between 05.3. Phase error adjustment:
Rotate the wheel until all fiveindicators at the inner side of thedisplay panel are lit. Observe whetherthecounterweight is at the bottom of thewheel rim or not.If it is, the phase value of PHA shouldnot be changed; if it isnt, the phase
value of PHA should be increased ordecreased.
4. Pro should be set as OFF.
Press key to adjust the parameters.