Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite...

65
Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Transcript of Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite...

Page 1: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Cover

Manager

for System2000, System3000,

PM add-on, Pasolink and nLite

User’s Guide

Revision 3.1.0 Page 1

Page 2: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 2

Table of Contents

Cover .............................................................................................................................................. 1 Preface ............................................................................................................................................ 4 

Warranty ..................................................................................................................................... 4 License ........................................................................................................................................ 4 Audience and Purpose ................................................................................................................. 4 Organization of this User’s Guide .............................................................................................. 4 Obtaining Help ............................................................................................................................ 4 

Users Guide ............................................................................................................................. 4 World Wide Web Help ........................................................................................................... 5 • Links to Manufacturers: 5 

System Layout ............................................................................................................................... 6 Features for System2000 & System3000 .................................................................................... 6 Features for System3000 PM/Inventory/Add-on ........................................................................ 6 Features for Pasolink & nLite ..................................................................................................... 6 Requirements .............................................................................................................................. 6 Overview Drawing ...................................................................................................................... 7 Software of the Alarm Network .................................................................................................. 8 Location ...................................................................................................................................... 8 Grounding ................................................................................................................................... 8 Ethernet Considerations .............................................................................................................. 8 

Installation ..................................................................................................................................... 9 Configuration .............................................................................................................................. 10 

NEC 2000 and 3000 Microwave Radios .................................................................................. 10 Registration ........................................................................................................................... 10 Terminal Server .................................................................................................................... 10 OSI (optional) ....................................................................................................................... 11 NMS/SNMP Server .............................................................................................................. 11 Mail Server............................................................................................................................ 12 Microwave Radios ................................................................................................................ 12 

NEC Pasolink & nLite Family .................................................................................................. 14 Registration ........................................................................................................................... 14 LAN ...................................................................................................................................... 14 NMS/SNMP Server .............................................................................................................. 14 Mail Server............................................................................................................................ 14 Microwave Radios ................................................................................................................ 15 

Operation ..................................................................................................................................... 16 Starting and Stopping ................................................................................................................ 16 

As a service ........................................................................................................................... 16 As a program ......................................................................................................................... 16 As an Instance ....................................................................................................................... 16 

Menu Items ............................................................................................................................... 16 Start ....................................................................................................................................... 16 Stop ....................................................................................................................................... 16 LogWatcher ........................................................................................................................... 17 Uninstaller ............................................................................................................................. 17 Configuration ........................................................................................................................ 17 

Page 3: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 3

Logs....................................................................................................................................... 17 Inventory ...................................................................................................................................... 18 PM Add-on .................................................................................................................................. 19 

Data Gathering .......................................................................................................................... 19 Radios Database fields .............................................................................................................. 19 PM Database fields ................................................................................................................... 19 Remote Access .......................................................................................................................... 19 Access Data without Reports Wizard ....................................................................................... 19 

AlarmsPro Manager Telnet Commands ................................................................................... 20 Alarm Delivery and Format ....................................................................................................... 21 Appendix A - Multi-IP Addressing ........................................................................................... 22 

NEC 2000 Radio ....................................................................................................................... 23 NEC 3000 Radio ....................................................................................................................... 24 

Appendix B – Delivered Software Alarms ................................................................................ 25 2000 & 3000 Series Radios....................................................................................................... 25 nLite & Pasolink Series Radios ................................................................................................ 25 

Appendix C – System2000 Radio Alarms ................................................................................. 26 Appendix D – System3000 Radio Alarms ................................................................................. 41 Appendix E – SCS100 Installation and Configuration ............................................................ 61 sample.properties ........................................................................................................................ 62 Sample.db.properties .................................................................................................................. 64 log4j.properties............................................................................................................................ 65 

Page 4: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Preface This document is provided to give an understanding of the AlarmsPro SNMP interface system for the NEC Microwave. Although it can be installed as an application, the most common method to install AlarmsPro for System2000, System3000, PM/Inventory add-on, Pasolink, and nLite is as a service or daemon that runs in the background.

Warranty AlarmsPro Manager for System2000, System3000, PM/Inventory add-on, Pasolink, and nLite comes with a six (6) month parts and labor warranty. For the complete license and warranty information, see the AlarmsPro License in the licenses directory.

License Licenses are located in the “AlarmsPro\licenses” directory.

Audience and Purpose This manual provides information about the setup and configuration of the alarm system and associated delivery devices. The manual is intended to be used by IT Department personnel and supervisors of alarming systems.

Organization of this User’s Guide The AlarmsPro User’s Guide is a single volume with information of special importance noted with the icons described below. The Tip Icon informs you of timesaving tips. The Caution Icon alerts you to areas of importance and potential problems.

Obtaining Help In addition to the below help formats, additional assistance can be obtained by calling AlarmsPro, Inc. help at 907-745-6312.

Users Guide This User’s Guide is designed to answer the most common questions about the AlarmsPro Manager for System2000, System3000, PM/Inventory add-on, Pasolink, and nLite software package.

Revision 3.1.0 Page 4

Page 5: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 5

World Wide Web Help

Links to Manufacturers: AlarmsPro, Inc. http://www.alarmspro.com/ InterMapper http://www.intermapper.com/ Lantronix http://www.lantronix.com/support/ NEC http://necam.com/

Page 6: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 6

System Layout

Features for System2000 & System3000 • Alarms are sent in industry standard SNMP trap protocol and can be sent to any Network

Management System (NMS) (Intermapper with AlarmsPro Enhancements is recommended). • Serial terminal server connection or optional OSI connection method. • Automatic background daemon/service with minimal operator configuration. • Conversion of both domestic (contacts) and radio (soft) alarms to SNMP. • Auto time setting of radio elements. • Single point of contact for all NEC 2000 and 3000 series microwave alarm points.

Over 700 different alarms are monitored on each radio. • No installation required at remote microwave sites. • Up to the break management (optional). • Report 32 input contact closures and output contact states. • Selective telemetering, including RSL, monitoring. • Inventory saved to files daily (OSI only)

Features for System3000 PM/Inventory/Add-on • Intergrated installation with AlarmsPro installer. • Fully dynamic operation based on radio configuration. • Includes all 15 minute and 24 hour PM data registers. • Up to 90 days of performance data is saved in an intergrated database. • Individual radio selectable for PM data. • Data can be retrieved by customer application, if desired.

Features for Pasolink & nLite • Alarms are sent in industry standard SNMP trap protocol and can be sent to any Network

Management System (NMS) (Intermapper with AlarmsPro Enhancements is recommended). • Connections are automatically managed to route incoming SNMP traps from radios to the

NMS. • Up to three (3) NMS’s supported.

Requirements AlarmsPro System2000, System3000, PM/Inventory Add-on, and Pasolink/nLite are cross platform compatible and will run on most Operating Systems(Os’s) including Solaris SPARC and x86 as well as, Linux (Red Hat, Mandrake, Debian), FreeBSD, Windows NT/2000/XP/2003 and MacOS X. AlarmsPro with PM – Pentium 2Ghz or higher (Core 2 Duo recommended on systems over 40 NE’s), 7200 RPM Hard disk drive with 200 GB available. Drive space estimate does not account for the requirements of the Report_Wizard output files.

Page 7: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Overview Drawing

The Network Management System (NMS) computer houses InterMapper with AlarmsPro Enhancements or other NMS software and the AlarmsPro Manager for System2000, System3000, Pasolink, and nLite software. The NMS is capable of watching networked routers, switches, remote monitoring devices, UPS's and microwave alarms. The NMS generally offers web and Java based GUI displays of system alarms and provides a means of notification via email, pager, SMS cell phone or audio alerts. InterMapper with AlarmsPro Enhancements is capable of verbal audio alerts. At the main remote microwave site, a terminal server is used to convert the microwaves serial data to TCP/IP. The AlarmsPro Manager is responsible to keep the connection to the radio live and if the connection fails it will attempt to regain continuity while notifying the NMS with a TRAP message that a connection has failed.

Revision 3.1.0 Page 7

Page 8: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Software of the Alarm Network • AlarmsPro Manager for System2000, System3000, Pasolink, and nLite • InterMapper (as required, Network Monitor System (NMS)) • InterMapper Remote (as required, remote display)

Location The AlarmsPro Manager for System2000, System3000, Pasolink, and nLite daemon can be placed on any computer meeting the system requirements. However, it might be best suited on the same computer as the NMS. Network connectivity is required to the initial microwave terminal. Only one microwave needs to be connected to the system per instance. All other radios are viewed through that terminal. The community read/write string in the primary NMS must be set to “public”/“public”. If more than one (1) NMS is used, the community strings used in the secondary NMS’s must be set to “generic”/”generic”. Network reliability from the AlarmsPro Manager to the NMS is required. Placing the daemon/service directly on the NMS has minimal impact on the processor.

Grounding A properly installed ground reference is important to prevent static electricity from causing problems. Information technology industry standard procedures are recommended whenever you are working on the system.

Ethernet Considerations Network reliability from the AlarmsPro Manager to the NMS and to the Network Elements is required.

• Keep all electrical noise generating devices as far away from the system as possible. • Ethernet cabling should be appropriate for the network. • When OSI connectivity over ethernet is used for 2000 or 3000 microwave networks,

every effort should be made to seperate the TCP and OSI traffic. • Any OSI traffic passed through a router requires configuring the router for OSI traffic.

Revision 3.1.0 Page 8

Page 9: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Installation The installation of the AlarmsPro Manager software is accomplished on major operating systems by launching the installer application and stepping through the installation screens. Installation must be done as an administrator. On Windows operating systems, the AlarmsPro Manager must be installed as a service. If the installer finds that your system currently has an outdated version of Java or does not have the program it will attempt to download and install a new version of Java. An Internet connection is required for this download. It is important to note that this download will only install the basic requirements required by the Java Runtime Engine (JRE) to the AlarmsPro folder and does not load the full Java application. If you require Java for other applications please download the full version from http://www.sun.com.

1. Launching the installer will bring up the Welcome screen. 2. Accept the AlarmsPro License Agreement. If you do not accept the license, the installer

will quit. 3. Select the program Destination Directory –

• The default directory for a Windows installation is: C:\Program Files\AlarmsPro. • The default directory for a Macintosh OSX installation is: /Applications/AlarmsPro

4. Select Start Menu Folder (Windows Only)- If you intend to allow other users to run the program, be sure to select “Create shortcuts for all users”.

5. Windows Services – AlarmsPro Manager should be installed as a service in Windows. It is highly recommended that the service “Start on bootup”. • On Macintosh OSX this screen will be Startup Items and contain Install startup item

"AlarmsPro". After Installation is complete, launch the AlarmsPro Manager to configure system.

Revision 3.1.0 Page 9

Page 10: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Configuration The AlarmsPro Manager controls all aspects of configuration and the instances of the service/daemon. Default password for the AlarmsPro Manager is “admin”. The administrator password is changed from the Monitors tab of the AlarmsPro Manager. Press New on the Properties tab to start configuring an instance of AlarmsPro Manager for System2000, System3000, Pasolink, and nLite . Insert a name for the new instance. The type of equipment to be monitored by the instance is determined by the serial number of that instance. Changes are saved on a per screen basis. Be sure to save any changes before going to the next screen.

NEC 2000 and 3000 Microwave Radios Step through the remaining screens and fill in the appropriate information.

Registration Fill in the Company name and Serial Number as provided with your license from AlarmsPro, Inc.

Terminal Server IP Address and Port Number of the Terminal Server attached to the NEC Radio. If the SSH connection method is used, a login and password to the Terminal Server are required. Redundancy information is optional.

Revision 3.1.0 Page 10

Page 11: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

OSI (optional) IP Address of the OSI converter is provided as a virtual address to receive connectivity issue traps. This allows the NMS to display connectivity problems/alarms.

NMS/SNMP Server IP Address of the NMS (127.0.0.1 if on the same computer and 0.0.0.0 to disable). Port Number the NMS watches (Typically 162). SNMP Community (public). Microwave ID (254). The IP Address can be multiple addresses separated by “,” and may include a port number. eg. 192.168.1.1:162,127.0.0.1:161

Revision 3.1.0 Page 11

single IP address. Default = 10.254.x.1 where

Yes – Sends the traps for a radio’s alarms to multiple IP addresses to allow lighting separate

Perform Multi-IP Radio Lookup – Assigns multiple IP addresses for each radio.

No – Sends the traps for a radio’s alarms to a"x" is the ID of the radio in the Microwave Radio Properties.

icons based on the specific module in the radio. Default = 10.254.x.y where "x" is the ID of the radio in the Microwave Radio Properties and “y” is the alarm point in the radio. (See Appendix A - Multi-IP Addressing in the User’s Guide for more information.)

Page 12: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Mail Server SMTP Host is your outbound mail server and can be in the form of 127.0.0.1 or mail.yourcompany.com. Email address is where all AlarmsPro System2000 or System3000 program alarms (such as connection to the Terminal Server) are to be delivered and can be any valid address such as [email protected]. Only AlarmsPro program alarms (such as connection to the Terminal Server) will be delivered to this address, not NEC Radio alarms.

Microwave Radios

Revision 3.1.0 Page 12

ervice

ID y

)

ime Synchronize, when enabled will set the

X Pwr and RSL values must be between –99 to +99. If left blank, default values of +17 and –

ll radios MUST have a unique ID for Multi-IP Radio alarm delivery regardless of the number

nable PM is selectable on a per radio basis. When enabled, all PM registers will be

o add a radio, fill in the radio properties and press save or highlight an existing radio, make

o remove a radio, highlight the radio entry then press Remove.

Fill in the Radio Name, the Network Service Access Point (NSAP) and the Transport SAccess Point (TSAP). If the optional IP address field is used, all alarms for the radio will be delivered to the single IP only. The optionalfield is the third octet of radio alarm deliver(See Perform Multi-IP Radio Lookup above. Tclock in the radio to the computer time every 24hours. Advanced options are available in the properties file. (see sample.properties) T60 are used. Individual radio telemetering can be disabled by entering OFF in either the TX Pwr or RSL. Disabling either RX Pwr or RSL will disable both on that radio. Entering the TX Pwr or RSL value followed by “.a” will force the gathering of all TX Pwr AND RSL for that NE every keep-alive. (example. –60.a) Aof instances running. Econtinuously gathered and stored in the database for up to 90 days. Tthe necessary changes, then press save. T

Page 13: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 13

o change a radio entry, highlight the radio .

enable ce from the Properties tab of the

he last step is to start the instances from the onitors tab of the AlarmsPro Manager.

Tentry, make the changes, and then press "Save"When finished configuring the instance, the instanAlarmsPro Manager. TM

Page 14: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

NEC Pasolink & nLite Family Step through the remaining screens and fill in the appropriate information.

Registration Fill in the Company name and Serial Number as provided with your license from AlarmsPro, Inc.

LAN The IP Address and SNMP Port (typically port number 161) of the LAN interface of the attached NEC Radio. The Community is for both read and write access of the radio’s connection table. The SNMP Port and the Community String are for the LAN cable connected to the radio and is typically port 161 using a Community String of “public”.

Revision 3.1.0 Page 14

o NMS/SNMP Server IP Address of the NMS that service traps are tbe delivered (127.0.0.1 if on the same computer). Port Number the NMS watches for traps (Typically 162). SNMP Community (public). The community read/write string in the primary NMS must be set to “public”/“public”. If more than one (1) NMS is used, the community strings used in the secondary NMS’s must be set to “generic”/”generic”.

Mail Server SMTP Host is your outbound mail server and can be in the form of 127.0.0.1 or mail.yourcompany.com. Email address is where all AlarmsPro Manager program alarms (such as connection to the LAN port) are to be delivered and can be any valid address such as

Page 15: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

[email protected]. Mulitple addresses separated by a comma (,) are acceptable. This screen is for configuring delivery of AlarmsPro alarms, not network element alarms.

Microwave Radios Fill in the radio Name, the radio Read community, the radio Write community and the radio IP address. The Read community is typically “public” and the Write community is typically “public”. To add a radio, fill in the radio properties and press save or highlight an existing radio, make the necessary changes, then press save. To remove a radio, highlight the radio entry then press Remove. To change a radio entry, highlight the radio entry, make the changes, and then press "Save". When finished configuring, enable the instance from the Properties tab of the AlarmsPro Manager. And the last step is to start the instances from the Monitors tab of the AlarmsPro Manager.

Revision 3.1.0 Page 15

Page 16: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Operation

Starting and Stopping

As a service The AlarmsPro service can only be started or stopped as a system administrator and is accessed from the Services Management Console. A quick way to access the Services Management Console is by doing Start Menu -> Run -> services.msc

As a program AlarmsPro can only be started or stopped as a system administrator.

As an Instance Instances are controlled from the Monitors tab of the AlarmsPro Manager. In addition, information about the instance is displayed. The AlarmsPro service must be running for the Manager to connect.

Menu Items Menu Items are located in the Start Menu on a Windows system and are located in the bin directory under the Program Installation directory on Mac and Unix flavors. On a Mac OSX, the directory is typically /Applications/AlarmsPro/bin.

Start The Start item on the menu will start the daemon/service on Windows operating systems or the program on other operating systems if the current user has Administrator privledges. Starting and stopping the service or program will not change the startup type. If the service is set to automatically start on bootup and you stop the service from the menu, the services will start again on bootup. The AlarmsPro service is accessed from the Services Management Console. A quick way to access the Services Management Console is by doing Start Menu -> Run -> services.msc

Stop The Stop item on the menu will stop the daemon/service on Windows operating systems or the program on other operating systems if the current user is an Administrator.

Revision 3.1.0 Page 16

Page 17: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

LogWatcher The LogWatcher displays activity and events in real time and colorizes the log entries and can be started from the Manager.

Uninstaller The uninstaller will completely remove the AlarmsPro software. The configuration, logs, and users guide are not removed by the uninstaller. These files are typically located under the “Program Files/AlarmsPro” directory in Windows and typically /Applications/AlarmsPro/bin in Mac OSX.

Configuration The Configuration item on the menu is for direct access to the configuration files directory.

Logs The Logs item on the menu is for direct access to the log files directory.

Revision 3.1.0 Page 17

Page 18: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Inventory Inventory files are located under the program installation directory on a Windows system (typically C:\Program Files\AlarmsPro\logs\[instance name]\[radio name]\[year]\[month]\inventory\[yyyy-mm-dd.cvs]) and located under the logs directory on Mac and Unix flavors. Inventory can be controlled in the instance properties file with “inventory=”true[false]. Inventory is gathered every 8-10 hours. This allows radios to be updated, enhanced, and maintained without restarting AlarmsPro. If a new transmitter/receiver is installed, the new card will be detected. The inventory files are comma separated text files and contain the following fields: Date/Time Bay Panel Name Maker Name Manufacture Date Serial Number Code Number Version Care should be taken to ensure adequate disk space. The inventory files are never deleted by the software. Backups, archiving and directory cleanup on a regular basis is highly recommended. When opening inventory files with Excel, ensure all fields except Date/Time are set to text. Typically, start Excel and import text file from the data menu.

Revision 3.1.0 Page 18

Page 19: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 19

PM Add-on If global PM is selected data is continuously gathered from all PM enabled radios and stored in an integrated database. PM data is stored for up to 90 days in the database.

Data Gathering PM data gathering begins after the radio login proceedure. The PM registers are automatically gathered and based upon the previous inventory cycle.

Radios Database fields ID – Unique ID for Radio INSTANCE – Instance name NAME – Radio name NSAP – Radio NSAP TSAP – Radio TSAP TABLE_NAME – Table name where PM data is stored ACTIVE - LASTTIME – Last time a 15 minute PM register was gathered LASTDAILY – Last time a 24 hour PM register was gathered OFFSET – Time difference between radio and computer

PM Database fields DateTime_ISO DATE Daily (Y/N) – Entry is 24 hour register or 15 minute register bay – Bay number (1001-1006,2001,4001) system – System number command – PM register command Flag – 00=Valid data, 10=Invalid data(item exists, 11=Invalid data (item does not exist) TCN – 0=TCN has not occurred, 1=TCN has occurred OVF – 0=OVF has not occurred, 1=OVF has occrred Data – Value of PM register

Remote Access To enable remote access to the PM database, uncomment the line “#derby.drda.host=0.0.0.0” in the db.properties file that is located in the “C:\Program Files\AlarmsPro\conf\” directory. For more information, see the sample.db.properties.

Access Data without Reports Wizard Contact AlarmsPro for information about accessing data via SQL.

Page 20: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

AlarmsPro Manager Telnet Commands

Revision 3.1.0 Page 20

f

All AlarmsPro Manager Monitors tab commands can be accomplished using telnet access on port 30023 with a default password o“admin”. The telnet command is typically: “telnet <ip> 30023” Telnet commands: To get the current version:

INFO <admin password> To list the current processes:

LIST [<admin password>] To start/stop a given process:

START <admin password> <list process number> STOP <admin password> <list process number>

To list available instance properties that could be enabled: ENABLE <admin password> To enable/disable a given instance:

DISABLE <admin password> <instance property name> ENABLE <admin password> <instance property name>

To change the admin password:

PASS <admin password> <new password> <repeat new password> To terminate the current telnet session:

EXIT

Page 21: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 21

Alarm Delivery and Format Alarms from the NEC 2000 and 3000 series microwave radios are translated and delivered to Intermapper with AlarmsPro Enhancements or a Network Management System (NMS) via SNMP trap. The following sample trap is explained in the table below. Sample Trap – 02/06 00:53:33 trap 10.254.1.43 :: 1.3.6.1.4.1.19807 (0) { 1.1.1 : "PALMER", 1.1.2 : "01200105", 1.1.3 : "TRP & RP [1-3-1]: TX LEVEL ALM", 1.1.4 : "CLEAR", 1.1.5 : "10.16.15.112" } (via 127.0.0.1)

Item Description 02/06 Date 00:53:33 Time TRAP Type Message 10.254.1.43 Destination IP 1.3.6.1.4.1.19807 O.I.D. 1.1.1 VarBind_1 "PALMER" Node name TRAP sent for 1.1.2 VarBind_2 "01200104" Hex 1.1.3 VarBind_3 "TRP & RP [1-3-1]: TX LEVEL ALM"

Device with [Bay-Shelf-Position] : Alarm description. NOTE: 2000 series radios use [Device Number] NOT [Bay-Shelf-Position]

1.1.4 VarBind_4 "CLEAR" Alarm State via 127.0.0.1 The NMS address

frip1
Page 22: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Appendix A - Multi-IP Addressing Multi IP addressing sends traps for the radio’s alarms to multiple IP addresses. Currently, Multi-IP Addressing is available for 2000 and 3000 series radios. Intermapper with AlarmsPro Enhancements is designed specifically to work with Multi-IP Addressing. Multi-IP Addressing allows icon activation based on specific module alarms in the radio. Default = 10.254.x.y where "x" is the ID of the radio in the Radio Properties and “y” is the alarm point in the radio.

Revision 3.1.0 Page 22

Page 23: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 23

NEC 2000 Radio Shelf Pos Device Bay 1 Bay 2 Bay 3 Bay 4 Bay 5 Bay 6

0 1 Contacts 10 10 10 10 10 10 1 1 DC-DC CONV#1 11 53 93 133 173 212 1 2 DC-DC CONV#2 12 54 94 134 174 213 1 3 DC-DC CONV#3 13 55 95 135 175 214 1 4 DC-DC CONV#4 14 56 96 136 176 215 2 2 ACL#1 15 57 97 137 177 216 2 3 MOD#1 16 58 98 138 178 217 2 4 DEM#1 17 59 99 139 179 218 2 5 WS/DSC#1 18 60 100 140 180 219 2 6 MOD#2 19 61 101 141 181 220 2 7 DEM#2 20 62 102 142 182 221 2 9 MOD#3 21 63 103 143 183 222 2 10 DEM#3 22 64 104 144 184 223 2 11 WS/DSC#2 23 65 105 145 185 224 2 12 MOD#4 24 66 106 146 186 225 2 13 DEM#4 25 67 107 147 187 226 3 2 RMCI 26 26 26 26 26 26 3 3 LMS 27 27 27 27 27 27 3 4 SWO CTRL 28 68 108 148 188 227 3 5 140/150M,OPT INTFC#1 29 69 109 149 189 228 3 6 TR DIST 30 70 110 150 190 229 3 9 OH INTFC#1,OH EXT 31 71 111 151 191 230 3 10 OH INTFC#2 32 72 112 152 192 231 3 11 140/150M,OPT INTFC#2 33 73 113 153 193 232 3 12 CLK(L) 34 74 114 154 194 233 3 13 CLK(R) 35 75 115 155 195 234 3 14 140/150M,OPT INTFC#3 36 76 116 156 196 235 3 16 OH INTFC#3 37 77 117 157 197 236 3 17 OH INTFC#4 38 78 118 158 198 237 3 18 140/150M,OPT INTFC#4 39 79 119 159 199 238 4 1 ACL#2 40 80 120 160 200 239 4 2 RX UNIT#1 41 81 121 161 201 240 4 3 ATPC#1,HS SW CTRL 42 82 122 162 202 241 4 4 RX UNIT#2 43 83 123 163 203 242 4 5 ATPC#2 44 84 124 164 204 243 4 6 RX UNIT#3 45 85 125 165 205 244 4 7 ATPC#3 46 86 126 166 206 245 4 8 RX UNIT#4 47 87 127 167 207 246 4 9 ATPC#4 48 88 128 168 208 247 5 1 TX UNIT#1 49 89 129 169 209 248 5 2 TX UNIT#2 50 90 130 170 210 249 5 3 TX UNIT#3 51 91 131 171 211 250 5 4 TX UNIT#4 52 92 132 172 212 251

Page 24: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 24

NEC 3000 Radio The NEC 3000 series microwave radio Multi-IP system is based on a bay – shelf – card position system. All IP’s listed below start with 10.254.<Radio Number>.x

Shelf Pos Device Bay 1 Bay 2 Bay 3 Bay 4 Bay 5 Bay 60 1 Contacts 10 10 10 10 10 10 1 1 WS INTFC - 1 11 47 80 113 146 179 1 2 DC/DC - 1 12 48 81 114 147 180 1 3 DC/DC - 2 13 49 82 115 148 181 1 4 HS SWO CTRL/SWO PROC/SWO EXP 14 50 83 116 149 182 1 5 MODEM - 1 15 51 84 117 150 183 1 6 MODEM - 2 16 52 85 118 151 184 1 7 CLCK - 1 17 53 86 119 152 185 1 8 CLCK - 2 18 54 87 120 153 186 1 9 MODEM - 3 19 55 88 121 154 187 1 10 MODEM - 4 20 56 89 122 155 188 1 11 DC/DC - 3 21 57 90 123 156 189 1 12 DC/DC - 4 22 58 91 124 157 190 1 13 WS INTFC - 3/4 23 59 92 125 158 191 2 1 RMCI 24 24 24 24 24 24 2 2 LMS 25 25 25 25 25 25 2 3 OW 26 26 26 26 26 26 2 4 DIG HYB 27 60 93 126 159 192 2 5 CTRL 28 61 94 127 160 193 2 6 BB SW CTRL 29 62 95 128 161 194 2 7 TR DIST 30 63 96 129 162 195 2 11 OH EXT/OH INTFC - 1 31 64 97 130 163 196 2 11 OH EXT/OH INTFC - 1 31 64 97 130 163 196 2 11 OH EXT/OH INTFC - 1 31 64 97 130 163 196 2 11 OH EXT/OH INTFC - 1 31 64 97 130 163 196 2 12 140M - COPPER INTFC/150M - OPT INTFC (REG) - 1 32 65 98 131 164 197 2 13 140M - COPPER INTFC/150M - OPT INTFC (PROT) -1 33 66 99 132 165 198 2 14 OH INTFC - 2 34 67 100 133 166 199 2 15 140M - COPPER INTFC/150M - OPT INTFC (REG) - 2 35 68 101 134 167 200 2 16 140M - COPPER INTFC/150M - OPT INTFC (PROT) -2 36 69 102 135 168 201 2 17 OH INTFC - 3 37 70 103 136 169 202 2 18 140M - COPPER INTFC/150M - OPT INTFC (REG) - 3 38 71 104 137 170 203 2 19 140M - COPPER INTFC/150M - OPT INTFC (PROT) -3 39 72 105 138 171 204 2 20 OH INTFC - 4 40 73 106 139 172 205 2 21 140M - COPPER INTFC/150M - OPT INTFC (REG) - 4 41 74 107 140 173 206 2 22 140M - COPPER INTFC/150M - OPT INTFC (PROT) -4 42 75 108 141 174 207 3 1 TX_RX_1 43 76 109 142 175 208 3 2 TX_RX_2 44 77 110 143 176 209 3 3 TX_RX_3 45 78 111 144 177 210 3 4 TX_RX_4 46 79 112 145 178 211

Page 25: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 25

Appendix B – Delivered Software Alarms The AlarmsPro service delivers alarms to determine connectivity and configuration. The following table lists the valid software alarms.

2000 & 3000 Series Radios

HEX Alarm Text Level IP 0000001 Service Status CR Terminal Server IP0000002 Terminal Server Connection CR Terminal Server IP0000003 Unknown Radio MN [NMS IP] 0000004 Radio Timeout MJ Radio IP 0000005 Radio Summary Alarm MN [NMS IP] 0000006 Map Reset CR 10.254.x.0 0000007 No contact data reported MN Radio IP 0002007 Transmit Power CR Radio IP 0002008 Receive Level CR Radio IP

nLite & Pasolink Series Radios

HEX Alarm Text Level IP 0000001 Service Status CR LAN IP 0000002 LAN Connection CR LAN IP 0000004 Radio Timeout MJ Radio IP0000006 Map Reset CR Radio IP0000008 Connection Table Alarm MN Radio IP

Page 26: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 26

Appendix C – System2000 Radio Alarms

HEX Module Alarm Text Level 01000001 ACL PANEL SERVICE STATE ST1 01000004 ACL MODULE TYPE MISMATCH MJ 01000101 ACL SERIAL BUS ACCESS FAILURE MJ 01000102 ACL ACL ALM(EEPROM WRITE) MJ 01000103 ACL ACL ALM(EEPROM VERIFICATION) MJ 01000104 ACL ACL ALM(MEMORY R/W) MJ 01000105 ACL ACL ALM(PARAMETER) MJ 01000107 ACL ACL ALM(CALENDAR/TIMER) MJ 01000205 ACL MAINTENANCE(SYS1) ST1 01000206 ACL MAINTENANCE(SYS2) ST1 01000207 ACL MAINTENANCE(SYS3) ST1 01000208 ACL MAINTENANCE(SYS4) ST1 01010001 MOD PANEL SERVICE STATE ST1 01010004 MOD MODULE TYPE MISMATCH MJ 01010008 MOD MOD UNEQUIPPED ALM MJ 01010302 MOD OUTPUT LEVEL DOWN MJ 01010303 MOD ENCOD FAILURE MJ 01010306 MOD INPUT CLOCK LOSS MJ 01020001 DEM PANEL SERVICE STATE ST1 01020004 DEM MODULE TYPE MISMATCH MJ 01020008 DEM DEM UNEQUIPPED ALM MJ 01020105 DEM LOSS OF FRAME MJ 01020106 DEM OUT OF FRAME MJ 01020201 DEM INPUT LEVEL DOWN MJ 01020202 DEM DEM(CLOCK LOSS) ALM MJ 01020203 DEM DEM(CARR SYNC LOSS) ALM MJ 01020206 DEM XPIC ALM MJ 01020208 DEM XPIC RESET ST1 01020301 DEM SECTION LOW BER ALM MN 01020302 DEM SECTION HIGH BER ALM MJ 01020303 DEM HOP HIGH BER ALM MJ 01020304 DEM SIGNAL DEGRADE(B1) MN 01020305 DEM EXCESSIVE BER(B1) MJ 01020306 DEM FRAME SYNC LOSS MJ 01020307 DEM OUTPUT PULSE LOSS MJ 01020601 DEM TCN-15min OFS MN 01020602 DEM TCN-15min B1 BBE MN 01020603 DEM TCN-15min B1 ES MN 01020604 DEM TCN-15min B1 SES MN 01020605 DEM TCN-15min B1 UAS MN 01020701 DEM TCN-1day OFS MN 01020702 DEM TCN-1day B1 BBE MN 01020703 DEM TCN-1day B1 ES MN

Page 27: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 27

HEX Module Alarm Text Level 01020704 DEM TCN-1day B1 SES MN 01020705 DEM TCN-1day B1 UAS MN 01030001 WS/DSC INTFC PANEL SERVICE STATE ST1 01030004 WS/DSC INTFC MODULE TYPE MISMATCH MJ 01030008 WS/DSC INTFC WS/DSC INTFC UNEQUIPPED ALM MJ 01030101 WS/DSC INTFC WS TX SERVICE FAIL MJ 01030102 WS/DSC INTFC WS RX SERVICE FAIL MJ 01030103 WS/DSC INTFC WS PROT CH BER ALM MJ 01030104 WS/DSC INTFC WS REG CH BER ALM MJ 01030105 WS/DSC INTFC WS REG CH SELECTED ST2 01030106 WS/DSC INTFC DSC REG CH SELECTED ST2 01030201 WS/DSC INTFC WS1 PROT CH TX ALM MJ 01030202 WS/DSC INTFC WS2 PROT CH TX ALM MJ 01030203 WS/DSC INTFC WS1 REG CH TX ALM MJ 01030204 WS/DSC INTFC WS2 REG CH TX ALM MJ 01030205 WS/DSC INTFC WS1 PROT CH RX ALM MJ 01030206 WS/DSC INTFC WS2 PROT CH RX ALM MJ 01030207 WS/DSC INTFC WS1 REG CH RX ALM MJ 01030208 WS/DSC INTFC WS2 REG CH RX ALM MJ 01030303 WS/DSC INTFC WS1 AIS RCVD ST1 01030304 WS/DSC INTFC WS2 AIS RCVD ST1 01030307 WS/DSC INTFC WS1 AIS SEND ST1 01030308 WS/DSC INTFC WS2 AIS SEND ST1 01030401 WS/DSC INTFC DSC PROT CH TX ALM MJ 01030402 WS/DSC INTFC DSC REG CH TX ALM MJ 01030403 WS/DSC INTFC DSC PROT CH RX ALM MJ 01030404 WS/DSC INTFC DSC REG CH RX ALM MJ 01030405 WS/DSC INTFC DSC TX SERVICE FAIL MJ 01030406 WS/DSC INTFC DSC RX SERVICE FAIL MJ 01030407 WS/DSC INTFC DSC PROT BER ALM MJ 01030408 WS/DSC INTFC DSC REG BER ALM MJ 01100001 140/150M INTFC PANEL SERVICE STATE ST1 01100004 140/150M INTFC MODULE TYPE MISMATCH MJ 01100008 140/150M INTFC 140/150M INTFC UNEQUIPPED ALM MJ 01100202 140/150M INTFC HL SW OPERATION ST2 01100203 140/150M INTFC OUT OF FRAME ON REG MJ 01100204 140/150M INTFC OUT OF FRAME ON PROT ST1 01100306 140/150M INTFC REG DELAY MATCHED WITH PROT ST2 01100307 140/150M INTFC INPHASE ST2 01100802 140/150M INTFC AIS RECEIVED [FROM MUX] ST1 01100902 140/150M INTFC HO PATH FERF RECEIVED ST1 01100903 140/150M INTFC HO PATH SIGNAL LABEL MISMATCH ST1 01100904 140/150M INTFC HO PATH UNEQUIPPED RECEIVED ST1 01100906 140/150M INTFC EXCESSIVE BER(B3) [FROM DMR] MJ 01100907 140/150M INTFC 140/150M INTFC ALM(CPU/DDS) MJ 01100B01 140/150M INTFC PATH TRACE(J1) MISMATCH MJ 01100C01 140/150M INTFC MS-RDI(MS-FERF) RECEIVED [FROM MUX] ST1

Page 28: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 28

HEX Module Alarm Text Level 01100C02 140/150M INTFC MS-AIS RECEIVED [FROM MUX] ST1 01100C03 140/150M INTFC SIGNAL DEGRADE(B2) [FROM MUX] MN 01100C04 140/150M INTFC EXCESSIVE BER(B2) [FROM MUX] MJ 01100C05 140/150M INTFC SIGNAL DEGRADE(B1) [FROM MUX] MN 01100C07 140/150M INTFC LOSS OF FRAME [FROM MUX] MJ 01100C08 140/150M INTFC LOSS OF SIGNAL [FROM MUX] MJ 01100E03 140/150M INTFC AU PATH AIS3 RECEIVED [FROM MUX] ST1 01100E04 140/150M INTFC AU PATH AIS2 RECEIVED [FROM MUX] ST1 01100E05 140/150M INTFC AU PATH AIS1 RECEIVED [FROM MUX] ST1 01100E06 140/150M INTFC LOSS OF POINTER3 [FROM MUX] MJ 01100E07 140/150M INTFC LOSS OF POINTER2 [FROM MUX] MJ 01100E08 140/150M INTFC LOSS OF POINTER1 [FROM MUX] MJ 01101008 140/150M INTFC LOSS OF OUTPUT [TO MUX] MJ 01101101 140/150M INTFC MS-RDI(MS-FERF) RECEIVED [FROM DMR] ST1 01101102 140/150M INTFC MS-AIS RECEIVED [FROM DMR] ST1 01101103 140/150M INTFC SIGNAL DEGRADE(B2) [FROM DMR] MN 01101104 140/150M INTFC EXCESSIVE BER(B2) [FROM DMR] MJ 01101105 140/150M INTFC SIGNAL DEGRADE(B1) [FROM DMR] MN 01101106 140/150M INTFC EXCESSIVE BER(B1) [FROM DMR] MJ 01101107 140/150M INTFC LOSS OF FRAME [FROM DMR] MJ 01101108 140/150M INTFC LOSS OF SIGNAL [FROM DMR] MJ 01101303 140/150M INTFC AU PATH AIS3 RECEIVED [FROM DMR] ST1 01101304 140/150M INTFC AU PATH AIS2 RECEIVED [FROM DMR] ST1 01101305 140/150M INTFC AU PATH AIS1 RECEIVED [FROM DMR] ST1 01101306 140/150M INTFC LOSS OF POINTER3 [FROM DMR] MJ 01101307 140/150M INTFC LOSS OF POINTER2 [FROM DMR] MJ 01101308 140/150M INTFC LOSS OF POINTER1 [FROM DMR] MJ 01101504 140/150M INTFC 140/150M INTFC ALM(UNIT FAIL) MJ 01101801 140/150M INTFC TCN-15min OFS [FROM MUX] MN 01101802 140/150M INTFC TCN-15min B1 BBE [FROM MUX] MN 01101803 140/150M INTFC TCN-15min B1 ES [FROM MUX] MN 01101804 140/150M INTFC TCN-15min B1 SES [FROM MUX] MN 01101805 140/150M INTFC TCN-15min B2 BBE [FROM MUX] MN 01101806 140/150M INTFC TCN-15min B2 ES [FROM MUX] MN 01101807 140/150M INTFC TCN-15min B2 SES [FROM MUX] MN 01101808 140/150M INTFC TCN-15min FEBE(M1) BBE [FROM MUX] MN 01101901 140/150M INTFC TCN-15min FEBE(M1) ES [FROM MUX] MN 01101902 140/150M INTFC TCN-15min FEBE(M1) SES [FROM MUX] MN 01101903 140/150M INTFC TCN-15min B1 UAS [FROM MUX] MN 01101904 140/150M INTFC TCN-15min B2 UAS [FROM MUX] MN 01101905 140/150M INTFC TCN-15min FEBE(M1) UAS [FROM MUX] MN 01101906 140/150M INTFC TCN-15min P-PJC1 [FROM MUX] MN 01101907 140/150M INTFC TCN-15min N-PJC1 [FROM MUX] MN 01101908 140/150M INTFC TCN-15min P-PJC2 [FROM MUX] MN 01101A01 140/150M INTFC TCN-15min N-PJC2 [FROM MUX] MN 01101A02 140/150M INTFC TCN-15min P-PJC3 [FROM MUX] MN 01101A03 140/150M INTFC TCN-15min N-PJC3 [FROM MUX] MN

Page 29: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 29

HEX Module Alarm Text Level 01101A04 140/150M INTFC TCN-15min OFS [FROM DMR] MN 01101A05 140/150M INTFC TCN-15min B1 BBE [FROM DMR] MN 01101A06 140/150M INTFC TCN-15min B1 ES [FROM DMR] MN 01101A07 140/150M INTFC TCN-15min B1 SES [FROM DMR] MN 01101A08 140/150M INTFC TCN-15min B2 BBE [FROM DMR] MN 01101B01 140/150M INTFC TCN-15min B2 ES [FROM DMR] MN 01101B02 140/150M INTFC TCN-15min B2 SES [FROM DMR] MN 01101B03 140/150M INTFC TCN-15min FEBE(M1) BBE [FROM DMR] MN 01101B04 140/150M INTFC TCN-15min FEBE(M1) ES [FROM DMR] MN 01101B05 140/150M INTFC TCN-15min FEBE(M1) SES [FROM DMR] MN 01101B06 140/150M INTFC TCN-15min B1 UAS [FROM DMR] MN 01101B07 140/150M INTFC TCN-15min B2 UAS [FROM DMR] MN 01101B08 140/150M INTFC TCN-15min FEBE(M1) UAS [FROM DMR] MN 01101C01 140/150M INTFC TCN-15min P-PJC1 [FROM DMR] MN 01101C02 140/150M INTFC TCN-15min N-PJC1 [FROM DMR] MN 01101C03 140/150M INTFC TCN-15min P-PJC2 [FROM DMR] MN 01101C04 140/150M INTFC TCN-15min N-PJC2 [FROM DMR] MN 01101C05 140/150M INTFC TCN-15min P-PJC3 [FROM DMR] MN 01101C06 140/150M INTFC TCN-15min N-PJC3 [FROM DMR] MN 01101D01 140/150M INTFC TCN-15min B3 BBE [FROM DMR] MN 01101D02 140/150M INTFC TCN-15min B3 ES [FROM DMR] MN 01101D03 140/150M INTFC TCN-15min B3 SES [FROM DMR] MN 01101D04 140/150M INTFC TCN-15min B3 UAS [FROM DMR] MN 01101D05 140/150M INTFC TCN-15min FEBE(G1) BBE [FROM DMR] MN 01101D06 140/150M INTFC TCN-15min FEBE(G1) ES [FROM DMR] MN 01101D07 140/150M INTFC TCN-15min FEBE(G1) SES [FROM DMR] MN 01101D08 140/150M INTFC TCN-15min FEBE(G1) UAS [FROM DMR] MN 01101E01 140/150M INTFC TCN-1day OFS [FROM MUX] MN 01101E02 140/150M INTFC TCN-1day B1 BBE [FROM MUX] MN 01101E03 140/150M INTFC TCN-1day B1 ES [FROM MUX] MN 01101E04 140/150M INTFC TCN-1day B1 SES [FROM MUX] MN 01101E05 140/150M INTFC TCN-1day B2 BBE [FROM MUX] MN 01101E06 140/150M INTFC TCN-1day B2 ES [FROM MUX] MN 01101E07 140/150M INTFC TCN-1day B2 SES [FROM MUX] MN 01101E08 140/150M INTFC TCN-1day FEBE(M1) BBE [FROM MUX] MN 01101F01 140/150M INTFC TCN-1day FEBE(M1) ES [FROM MUX] MN 01101F02 140/150M INTFC TCN-1day FEBE(M1) SES [FROM MUX] MN 01101F03 140/150M INTFC TCN-1day B1 UAS [FROM MUX] MN 01101F04 140/150M INTFC TCN-1day B2 UAS [FROM MUX] MN 01101F05 140/150M INTFC TCN-1day FEBE(M1) UAS [FROM MUX] MN 01101F06 140/150M INTFC TCN-1day P-PJC1 [FROM MUX] MN 01101F07 140/150M INTFC TCN-1day N-PJC1 [FROM MUX] MN 01101F08 140/150M INTFC TCN-1day P-PJC2 [FROM MUX] MN 01102001 140/150M INTFC TCN-1day N-PJC2 [FROM MUX] MN 01102002 140/150M INTFC TCN-1day P-PJC3 [FROM MUX] MN 01102003 140/150M INTFC TCN-1day N-PJC3 [FROM MUX] MN 01102004 140/150M INTFC TCN-1day OFS [FROM DMR] MN

Page 30: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 30

HEX Module Alarm Text Level 01102005 140/150M INTFC TCN-1day B1 BBE [FROM DMR] MN 01102006 140/150M INTFC TCN-1day B1 ES [FROM DMR] MN 01102007 140/150M INTFC TCN-1day B1 SES [FROM DMR] MN 01102008 140/150M INTFC TCN-1day B2 BBE [FROM DMR] MN 01102101 140/150M INTFC TCN-1day B2 ES [FROM DMR] MN 01102102 140/150M INTFC TCN-1day B2 SES [FROM DMR] MN 01102103 140/150M INTFC TCN-1day FEBE(M1) BBE [FROM DMR] MN 01102104 140/150M INTFC TCN-1day FEBE(M1) ES [FROM DMR] MN 01102105 140/150M INTFC TCN-1day FEBE(M1) SES [FROM DMR] MN 01102106 140/150M INTFC TCN-1day B1 UAS [FROM DMR] MN 01102107 140/150M INTFC TCN-1day B2 UAS [FROM DMR] MN 01102108 140/150M INTFC TCN-1day FEBE(M1) UAS [FROM DMR] MN 01102201 140/150M INTFC TCN-1day P-PJC1 [FROM DMR] MN 01102202 140/150M INTFC TCN-1day N-PJC1 [FROM DMR] MN 01102203 140/150M INTFC TCN-1day P-PJC2 [FROM DMR] MN 01102204 140/150M INTFC TCN-1day N-PJC2 [FROM DMR] MN 01102205 140/150M INTFC TCN-1day P-PJC3 [FROM DMR] MN 01102206 140/150M INTFC TCN-1day N-PJC3 [FROM DMR] MN 01102301 140/150M INTFC TCN-1day B3 BBE [FROM DMR] MN 01102302 140/150M INTFC TCN-1day B3 ES [FROM DMR] MN 01102303 140/150M INTFC TCN-1day B3 SES [FROM DMR] MN 01102304 140/150M INTFC TCN-1day B3 UAS [FROM DMR] MN 01102305 140/150M INTFC TCN-1day FEBE(G1) BBE [FROM DMR] MN 01102306 140/150M INTFC TCN-1day FEBE(G1) ES [FROM DMR] MN 01102307 140/150M INTFC TCN-1day FEBE(G1) SES [FROM DMR] MN 01102308 140/150M INTFC TCN-1day FEBE(G1) UAS [FROM DMR] MN 01110001 OPT INTFC PANEL SERVICE STATE ST1 01110004 OPT INTFC MODULE TYPE MISMATCH MJ 01110008 OPT INTFC OPT INTFC UNEQUIPPED ALM MJ 01110101 OPT INTFC ALS IMPLEMENTED ST1 01110202 OPT INTFC HL SW OPERATION ST2 01110203 OPT INTFC OUT OF FRAME ON REG MJ 01110204 OPT INTFC OUT OF FRAME ON PROT ST1 01110306 OPT INTFC REG DELAY MATCHED WITH PROT ST2 01110307 OPT INTFC INPHASE ST2 01110601 OPT INTFC MS-RDI(MS-FERF) RECEIVED [FROM MUX] ST1 01110602 OPT INTFC MS-AIS RECEIVED [FROM MUX] ST1 01110603 OPT INTFC SIGNAL DEGRADE(B2) [FROM MUX] MN 01110604 OPT INTFC EXCESSIVE BER(B2) [FROM MUX] MJ 01110605 OPT INTFC SIGNAL DEGRADE(B1) [FROM MUX] MN 01110607 OPT INTFC LOSS OF FRAME [FROM MUX] MJ 01110608 OPT INTFC LOSS OF SIGNAL [FROM MUX] MJ 01110803 OPT INTFC AU PATH AIS3 RECEIVED [FROM MUX] ST1 01110804 OPT INTFC AU PATH AIS2 RECEIVED [FROM MUX] ST1 01110805 OPT INTFC AU PATH AIS1 RECEIVED [FROM MUX] ST1 01110806 OPT INTFC LOSS OF POINTER3 [FROM MUX] MJ 01110807 OPT INTFC LOSS OF POINTER2 [FROM MUX] MJ

Page 31: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 31

HEX Module Alarm Text Level 01110808 OPT INTFC LOSS OF POINTER1 [FROM MUX] MJ 01110A07 OPT INTFC LD BIAS ALM MJ 01110A08 OPT INTFC LOSS OF OUTPUT [TO MUX] MJ 01110B01 OPT INTFC MS-RDI(MS-FERF) RECEIVED [FROM DMR] ST1 01110B02 OPT INTFC MS-AIS RECEIVED [FROM DMR] ST1 01110B03 OPT INTFC SIGNAL DEGRADE(B2) [FROM DMR] MN 01110B04 OPT INTFC EXCESSIVE BER(B2) [FROM DMR] MJ 01110B05 OPT INTFC SIGNAL DEGRADE(B1) [FROM DMR] MN 01110B06 OPT INTFC EXCESSIVE BER(B1) [FROM DMR] MJ 01110B07 OPT INTFC LOSS OF FRAME [FROM DMR] MJ 01110B08 OPT INTFC LOSS OF SIGNAL [FROM DMR] MJ 01110D03 OPT INTFC AU PATH AIS3 RECEIVED [FROM DMR] ST1 01110D04 OPT INTFC AU PATH AIS2 RECEIVED [FROM DMR] ST1 01110D05 OPT INTFC AU PATH AIS1 RECEIVED [FROM DMR] ST1 01110D06 OPT INTFC LOSS OF POINTER3 [FROM DMR] MJ 01110D07 OPT INTFC LOSS OF POINTER2 [FROM DMR] MJ 01110D08 OPT INTFC LOSS OF POINTER1 [FROM DMR] MJ 01110F04 OPT INTFC OPT INTFC ALM(UNIT FAIL) MJ 01111201 OPT INTFC TCN-15min OFS [FROM MUX] MN 01111202 OPT INTFC TCN-15min B1 BBE [FROM MUX] MN 01111203 OPT INTFC TCN-15min B1 ES [FROM MUX] MN 01111204 OPT INTFC TCN-15min B1 SES [FROM MUX] MN 01111205 OPT INTFC TCN-15min B2 BBE [FROM MUX] MN 01111206 OPT INTFC TCN-15min B2 ES [FROM MUX] MN 01111207 OPT INTFC TCN-15min B2 SES [FROM MUX] MN 01111208 OPT INTFC TCN-15min FEBE(M1) BBE [FROM MUX] MN 01111301 OPT INTFC TCN-15min FEBE(M1) ES [FROM MUX] MN 01111302 OPT INTFC TCN-15min FEBE(M1) SES [FROM MUX] MN 01111303 OPT INTFC TCN-15min B1 UAS [FROM MUX] MN 01111304 OPT INTFC TCN-15min B2 UAS [FROM MUX] MN 01111305 OPT INTFC TCN-15min FEBE(M1) UAS [FROM MUX] MN 01111306 OPT INTFC TCN-15min P-PJC1 [FROM MUX] MN 01111307 OPT INTFC TCN-15min N-PJC1 [FROM MUX] MN 01111308 OPT INTFC TCN-15min P-PJC2 [FROM MUX] MN 01111401 OPT INTFC TCN-15min N-PJC2 [FROM MUX] MN 01111402 OPT INTFC TCN-15min P-PJC3 [FROM MUX] MN 01111403 OPT INTFC TCN-15min N-PJC3 [FROM MUX] MN 01111404 OPT INTFC TCN-15min OFS [FROM DMR] MN 01111405 OPT INTFC TCN-15min B1 BBE [FROM DMR] MN 01111406 OPT INTFC TCN-15min B1 ES [FROM DMR] MN 01111407 OPT INTFC TCN-15min B1 SES [FROM DMR] MN 01111408 OPT INTFC TCN-15min B2 BBE [FROM DMR] MN 01111501 OPT INTFC TCN-15min B2 ES [FROM DMR] MN 01111502 OPT INTFC TCN-15min B2 SES [FROM DMR] MN 01111503 OPT INTFC TCN-15min FEBE(M1) BBE [FROM DMR] MN 01111504 OPT INTFC TCN-15min FEBE(M1) ES [FROM DMR] MN 01111505 OPT INTFC TCN-15min FEBE(M1) SES [FROM DMR] MN

Page 32: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 32

HEX Module Alarm Text Level 01111506 OPT INTFC TCN-15min B1 UAS [FROM DMR] MN 01111507 OPT INTFC TCN-15min B2 UAS [FROM DMR] MN 01111508 OPT INTFC TCN-15min FEBE(M1) UAS [FROM DMR] MN 01111601 OPT INTFC TCN-15min P-PJC1 [FROM DMR] MN 01111602 OPT INTFC TCN-15min N-PJC1 [FROM DMR] MN 01111603 OPT INTFC TCN-15min P-PJC2 [FROM DMR] MN 01111604 OPT INTFC TCN-15min N-PJC2 [FROM DMR] MN 01111605 OPT INTFC TCN-15min P-PJC3 [FROM DMR] MN 01111606 OPT INTFC TCN-15min N-PJC3 [FROM DMR] MN 01111701 OPT INTFC TCN-1day OFS [FROM MUX] MN 01111702 OPT INTFC TCN-1day B1 BBE [FROM MUX] MN 01111703 OPT INTFC TCN-1day B1 ES [FROM MUX] MN 01111704 OPT INTFC TCN-1day B1 SES [FROM MUX] MN 01111705 OPT INTFC TCN-1day B2 BBE [FROM MUX] MN 01111706 OPT INTFC TCN-1day B2 ES [FROM MUX] MN 01111707 OPT INTFC TCN-1day B2 SES [FROM MUX] MN 01111708 OPT INTFC TCN-1day FEBE(M1) BBE [FROM MUX] MN 01111801 OPT INTFC TCN-1day FEBE(M1) ES [FROM MUX] MN 01111802 OPT INTFC TCN-1day FEBE(M1) SES [FROM MUX] MN 01111803 OPT INTFC TCN-1day B1 UAS [FROM MUX] MN 01111804 OPT INTFC TCN-1day B2 UAS [FROM MUX] MN 01111805 OPT INTFC TCN-1day FEBE(M1) UAS [FROM MUX] MN 01111806 OPT INTFC TCN-1day P-PJC1 [FROM MUX] MN 01111807 OPT INTFC TCN-1day N-PJC1 [FROM MUX] MN 01111808 OPT INTFC TCN-1day P-PJC2 [FROM MUX] MN 01111901 OPT INTFC TCN-1day N-PJC2 [FROM MUX] MN 01111902 OPT INTFC TCN-1day P-PJC3 [FROM MUX] MN 01111903 OPT INTFC TCN-1day N-PJC3 [FROM MUX] MN 01111904 OPT INTFC TCN-1day OFS [FROM DMR] MN 01111905 OPT INTFC TCN-1day B1 BBE [FROM DMR] MN 01111906 OPT INTFC TCN-1day B1 ES [FROM DMR] MN 01111907 OPT INTFC TCN-1day B1 SES [FROM DMR] MN 01111908 OPT INTFC TCN-1day B2 BBE [FROM DMR] MN 01111A01 OPT INTFC TCN-1day B2 ES [FROM DMR] MN 01111A02 OPT INTFC TCN-1day B2 SES [FROM DMR] MN 01111A03 OPT INTFC TCN-1day FEBE(M1) BBE [FROM DMR] MN 01111A04 OPT INTFC TCN-1day FEBE(M1) ES [FROM DMR] MN 01111A05 OPT INTFC TCN-1day FEBE(M1) SES [FROM DMR] MN 01111A06 OPT INTFC TCN-1day B1 UAS [FROM DMR] MN 01111A07 OPT INTFC TCN-1day B2 UAS [FROM DMR] MN 01111A08 OPT INTFC TCN-1day FEBE(M1) UAS [FROM DMR] MN 01111B01 OPT INTFC TCN-1day P-PJC1 [FROM DMR] MN 01111B02 OPT INTFC TCN-1day N-PJC1 [FROM DMR] MN 01111B03 OPT INTFC TCN-1day P-PJC2 [FROM DMR] MN 01111B04 OPT INTFC TCN-1day N-PJC2 [FROM DMR] MN 01111B05 OPT INTFC TCN-1day P-PJC3 [FROM DMR] MN 01111B06 OPT INTFC TCN-1day N-PJC3 [FROM DMR] MN

Page 33: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 33

HEX Module Alarm Text Level 01130001 TR DIST PANEL SERVICE STATE ST1 01130004 TR DIST MODULE TYPE MISMATCH MJ 01130008 TR DIST TR DIST UNEQUIPPED ALM MJ 01130201 TR DIST SYS1 TX SW OPERATION ST2 01130202 TR DIST SYS2 TX SW OPERATION ST2 01130203 TR DIST SYS3 TX SW OPERATION ST2 01130204 TR DIST SYS4 TX SW OPERATION ST2 01130305 TR DIST SYS1 AL INTFC ALM MJ 01130306 TR DIST SYS2 AL INTFC ALM MJ 01130307 TR DIST SYS3 AL INTFC ALM MJ 01130308 TR DIST SYS4 AL INTFC ALM MJ 01130401 TR DIST TX PROT ACCESS OPERATION ST2 01130402 TR DIST RX PROT ACCESS OPERATION ST2 01150001 CLK PANEL SERVICE STATE ST1 01150004 CLK MODULE TYPE MISMATCH MJ 01150008 CLK CLK UNEQUIPPED ALM MJ 01150102 CLK CLK MODULE ALM(INPUT) MJ 01150203 CLK EXTERNAL OUTPUT2 CLOCK LOSS MJ 01150204 CLK EXTERNAL INPUT2 AIS RECEIVED ST1 01150205 CLK EXTERNAL INPUT2 SIGNAL LOSS MJ 01150206 CLK CLK MODULE ALM(VCO) MJ 01150208 CLK SELECTED SOURCE LOSS MJ 01150301 CLK CLK ONLINE ST2 01150303 CLK EXTERNAL OUTPUT1 CLOCK LOSS MJ 01150304 CLK EXTERNAL INPUT1 AIS RECEIVED ST1 01150305 CLK EXTERNAL INPUT1 SIGNAL LOSS MJ 01150306 CLK CLK MODULE ALM(OUTPUT) MJ 01150307 CLK INTERNAL CLOCK LOSS MJ 01150308 CLK CLK MODULE ALM(OSC) MJ 01150C03 CLK REG3 DMR SLAVE CLOCK LOSS MJ 01150C04 CLK REG3 MUX SLAVE CLOCK LOSS MJ 01150C05 CLK REG2 DMR SLAVE CLOCK LOSS MJ 01150C06 CLK REG2 MUX SLAVE CLOCK LOSS MJ 01150C07 CLK REG1 DMR SLAVE CLOCK LOSS MJ 01150C08 CLK REG1 MUX SLAVE CLOCK LOSS MJ 01150D01 CLK EXT#1 CLK SELECTED FOR EQUIPMENT ST2 01150D02 CLK EXT#2 CLK SELECTED FOR EQUIPMENT ST2 01150D05 CLK MUX1 CLK SELECTED FOR EQUIPMENT ST2 01150D06 CLK MUX2 CLK SELECTED FOR EQUIPMENT ST2 01150D07 CLK DMR1 CLK SELECTED FOR EQUIPMENT ST2 01150D08 CLK DMR2 CLK SELECTED FOR EQUIPMENT ST2 01150D09 CLK INTERNAL CLK SELECTED FOR EQUIPMENT ST2 01150D11 CLK MUX1 CLK SELECTED FOR LINE ST2 01150D12 CLK MUX2 CLK SELECTED FOR LINE ST2 01150D13 CLK DMR1 CLK SELECTED FOR LINE ST2 01150D14 CLK DMR2 CLK SELECTED FOR LINE ST2 01150D22 CLK SLAVE CLK SELECTED FOR EQUIPMENT ST2

Page 34: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 34

HEX Module Alarm Text Level 01150D31 CLK Select EXT OUT source Equipment ST2 01150D32 CLK Select EXT OUT source Line ST2 01160001 OH INTFC PANEL SERVICE STATE ST1 01160004 OH INTFC MODULE TYPE MISMATCH MJ 01160008 OH INTFC OH INTFC UNEQUIPPED ALM MJ 01160102 OH INTFC FM MUX DROP CLK LOSS MJ 01160103 OH INTFC DEM(REG) DROP CLK LOSS MJ 01160104 OH INTFC POH INS CLK LOSS MJ 01160105 OH INTFC TO DMR ()INTFC INS CLK LOSS MJ 01160106 OH INTFC MOD(REG) INS CLK LOSS MJ 01160201 OH INTFC MOD(PROT) INS CLK LOSS MJ 01160202 OH INTFC TO DMR G703-1 AIS RCVD ST1 01160203 OH INTFC TO DMR G703-2 AIS RCVD ST1 01160204 OH INTFC TO DMR G703-3 AIS RCVD ST1 01160205 OH INTFC STBY CH ALM MJ 01160206 OH INTFC FM MUX TO DMR SERVICE FAIL MJ 01160305 OH INTFC DSC INS CLK LOSS MJ 01160306 OH INTFC DSC DROP CLK LOSS MJ 01160307 OH INTFC DSC F ASYNC MJ 01160404 OH INTFC TO DMR INS VCO LOSS MJ 01160405 OH INTFC FM MUX DROP VCO LOSS MJ 01160407 OH INTFC RSOH PROT CH SELECTED ST2 01160408 OH INTFC DEM(REG) F ASYNC MJ 01160701 OH INTFC POH DROP CLK LOSS MJ 01160702 OH INTFC FM DMR DROP CLK LOSS MJ 01160703 OH INTFC DEM(REG) DROP CLK LOSS MJ 01160705 OH INTFC TO MUX ()INTFC INS CLK LOSS MJ 01160802 OH INTFC TO MUX G703-1 AIS RCVD ST1 01160803 OH INTFC TO MUX G703-2 AIS RCVD ST1 01160804 OH INTFC TO MUX G703-3 AIS RCVD ST1 01160805 OH INTFC FM DMR TO MUX STBY CH FAIL MJ 01160806 OH INTFC FM DMR TO MUX SERVICE FAIL MJ 01160906 OH INTFC DSC DROP CLK LOSS MJ 01160907 OH INTFC DSC F ASYNC MJ 01160A04 OH INTFC TO MUX INS VCO LOSS MJ 01160A05 OH INTFC FM DMR DROP VCO LOSS MJ 01160A07 OH INTFC FM DMR RSOH PROT CH SELECTED ST2 01160A08 OH INTFC DEM(REG) F ASYNC MJ 01170001 OH EXT PANEL SERVICE STATE ST1 01170004 OH EXT MODULE TYPE MISMATCH MJ 01170008 OH EXT OH EXT UNEQUIPPED ALM MJ 01170301 OH EXT TO MUX G703-2 INS PLS LOSS MJ 01170302 OH EXT FM DMR G703-2 DROP PLS LOSS MJ 01170303 OH EXT TO DMR G703-2 INS PLS LOSS MJ 01170304 OH EXT FM MUX@T/DMR@R G703-2 DROP PLS LOSS MJ 01170305 OH EXT TO MUX G703-1 INS PLS LOSS MJ 01170306 OH EXT FM DMR G703-1 DROP PLS LOSS MJ

Page 35: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 35

HEX Module Alarm Text Level 01170307 OH EXT TO DMR G703-1 INS PLS LOSS MJ 01170308 OH EXT FM MUX@T/DMR@R G703-1 DROP PLS LOSS MJ 01170402 OH EXT OH INTFC UNEQUIPPED ALM MJ 01170403 OH EXT G703 AIS RCVD TOTAL ST1 01170405 OH EXT TO MUX G703-3 INS PLS LOSS MJ 01170406 OH EXT FM DMR G703-3 DROP PLS LOSS MJ 01170407 OH EXT TO DMR G703-3 INS PLS LOSS MJ 01170408 OH EXT FM MUX@T/DMR@R G703-3 DROP PLS LOSS MJ 01180001 SWO CTRL PANEL SERVICE STATE ST1 01180004 SWO CTRL MODULE TYPE MISMATCH MJ 01180008 SWO CTRL SWO CTRL UNEQUIPPED ALM MJ 01180201 SWO CTRL HL SW OPERATION ST2 01180207 SWO CTRL SERVICE FAIL MJ 013F0001 DC-DC CONV PANEL SERVICE STATE ST1 013F0004 DC-DC CONV MODULE TYPE MISMATCH MJ 013F0008 DC-DC CONV DC-DC CONV UNEQUIPPED ALM MJ 013F0101 DC-DC CONV PS ALM MJ 01400001 TX UNIT PANEL SERVICE STATE ST1 01400004 TX UNIT MODULE TYPE MISMATCH MJ 01400008 TX UNIT TX UNIT UNEQUIPPED ALM MJ 01400306 TX UNIT ATPC MANU SW ST2 01400307 TX UNIT TX PWR ALM MJ 01400308 TX UNIT TX APC ALM MJ 01500001 RX UNIT PANEL SERVICE STATE ST1 01500004 RX UNIT MODULE TYPE MISMATCH MJ 01500008 RX UNIT RX UNIT UNEQUIPPED ALM MJ 01500207 RX UNIT SD IN LEV DOWN MN 01500208 RX UNIT MAIN IN LEV DOWN MN 01500302 RX UNIT EPS CTRL ST1 01500303 RX UNIT PHASE ALM MJ 01500304 RX UNIT SD IN LEV ALM MJ 01500305 RX UNIT MAIN IN LEV ALM MJ 01500306 RX UNIT AGC CTRL ST1 01500307 RX UNIT RX IN LEV ALM MJ 01500308 RX UNIT RX APC ALM MJ 015C0308 RX UNIT LO LEV ALM MJ 01600001 ATPC PANEL SERVICE STATE ST1 01600004 ATPC MODULE TYPE MISMATCH MJ 01600008 ATPC ATPC UNEQUIPPED ALM MJ 01600303 ATPC ATPC DATA LOSS MJ 01600305 ATPC PWR MIN CTRL STAT ST2 01600306 ATPC COMMUNICATION ALM MJ 01600307 ATPC ANSWER BACK ALM MJ 01600308 ATPC CPU ALM MJ 01610001 ATPC AUX PANEL SERVICE STATE ST1 01610004 ATPC AUX MODULE TYPE MISMATCH MJ 01610008 ATPC AUX ATPC AUX UNEQUIPPED ALM MJ

Page 36: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 36

HEX Module Alarm Text Level 01610303 ATPC AUX ATPC DATA LOSS MJ 01610305 ATPC AUX PWR MIN CTRL STAT ST2 01610306 ATPC AUX COMMUNICATION ALM MJ 01610307 ATPC AUX ANSWER BACK ALM MJ 01610308 ATPC AUX CPU ALM MJ 01620001 HS SW CTRL PANEL SERVICE STATE ST1 01620004 HS SW CTRL MODULE TYPE MISMATCH MJ 01620008 HS SW CTRL HS SW CTRL UNEQUIPPED ALM MJ 01620201 HS SW CTRL HS SW OPERATION ST2 01620206 HS SW CTRL FRAME SYNC LOSS AT FAR-END ST1 01620207 HS SW CTRL SERVICE FAIL MJ 01C30103 WS/DSC INTFC WS2 BER ALM MJ 01C30104 WS/DSC INTFC WS1 BER ALM MJ 01C30201 WS/DSC INTFC WS2 TX ALM MJ 01C30203 WS/DSC INTFC WS1 TX ALM MJ 01C30205 WS/DSC INTFC WS2 RX ALM MJ 01C30207 WS/DSC INTFC WS1 RX ALM MJ 01C30301 WS/DSC INTFC WS2 AIS RCVD ST1 01C30303 WS/DSC INTFC WS1 AIS RCVD ST1 01C30305 WS/DSC INTFC WS2 AIS SEND ST1 01C30307 WS/DSC INTFC WS1 AIS SEND ST1 01D30103 WS/DSC INTFC WS3/4 BER ALM MJ 01D30104 WS/DSC INTFC WS1/2 BER ALM MJ 01D30201 WS/DSC INTFC WS3 TX ALM MJ 01D30202 WS/DSC INTFC WS4 TX ALM MJ 01D30203 WS/DSC INTFC WS1 TX ALM MJ 01D30204 WS/DSC INTFC WS2 TX ALM MJ 01D30205 WS/DSC INTFC WS3 RX ALM MJ 01D30206 WS/DSC INTFC WS4 RX ALM MJ 01D30207 WS/DSC INTFC WS1 RX ALM MJ 01D30208 WS/DSC INTFC WS2 RX ALM MJ 01D30301 WS/DSC INTFC WS3 AIS RCVD ST1 01D30302 WS/DSC INTFC WS4 AIS RCVD ST1 01D30303 WS/DSC INTFC WS1 AIS RCVD ST1 01D30304 WS/DSC INTFC WS2 AIS RCVD ST1 01D30305 WS/DSC INTFC WS3 AIS SEND ST1 01D30306 WS/DSC INTFC WS4 AIS SEND ST1 01D30307 WS/DSC INTFC WS1 AIS SEND ST1 01D30308 WS/DSC INTFC WS2 AIS SEND ST1 01D60102 OH INTFC DROP CLK LOSS MJ 01D60202 OH INTFC G703-1 AIS RCVD ST1 01D60203 OH INTFC G703-2 AIS RCVD ST1 01D60204 OH INTFC G703-3 AIS RCVD ST1 01D60206 OH INTFC SERVICE FAIL MJ 01D60404 OH INTFC INS VCO LOSS MJ 01D60405 OH INTFC DROP VCO LOSS MJ 02000001 SWO PROC Switching Count ST1

Page 37: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 37

HEX Module Alarm Text Level 02000002 SWO PROC Switching Fail Count ST1 02000003 SWO PROC Switching Duration ST1 02000004 SWO PROC *MANUAL EXER. ST1 02000005 SWO PROC *EXER. OK ST1 02000006 SWO PROC FSYNC ALM Count ST1 02000008 SWO PROC BER ALM Duration ST1 02000009 SWO PROC FSYNC ALM Duration ST1 02000101 SWO PROC F SYNC ALM(REG) MJ 02000102 SWO PROC BER ALM(REG) MJ 02000104 SWO PROC RCVY(REG) ST1 02000105 SWO PROC TIM ALM(REG) MJ 02000106 SWO PROC SVCE FAIL(REG) CR 02000107 SWO PROC PSWO(REG) ST1 02000203 SWO PROC TX SW ANS(REG) ST1 02000204 SWO PROC HL SW ANS(REG) ST1 02000208 SWO PROC INTF ALM(REG) MJ 02000304 SWO PROC TX TEST OP(REG) ST1 02000305 SWO PROC SYNC TX SW OP(REG) ST1 02000307 SWO PROC DSBL OP(REG) ST1 02000308 SWO PROC COUNT STOP(REG) ST1 02000401 SWO PROC EXER WAIT(REG) ST1 02000402 SWO PROC HE ALM RST(REG) ST1 02000403 SWO PROC HE ALM INIT(REG) ST1 02000404 SWO PROC HE ALM PREV(REG) ST1 02000405 SWO PROC TIM ALM E(REG) MJ 02000406 SWO PROC TX ALM(REG) MJ 02000407 SWO PROC DSBL(REG) ST1 02000408 SWO PROC EXER ALM(REG) MJ 02000501 SWO PROC F SYNC ALM I(REG) MJ 02000502 SWO PROC BER ALM I(REG) MJ 02000505 SWO PROC TIM ALM I(REG) ST1 02000603 SWO PROC TX SW ANS I(REG) ST1 02000604 SWO PROC HL SW ANS I(REG) ST1 02000705 SWO PROC TCN-15MIN SWO FAIL DUR(REG) MN 02000706 SWO PROC TCN-15MIN SWO DUR(REG) MN 02000707 SWO PROC TCN-15MIN SWO FAIL CNT(REG) MN 02000708 SWO PROC TCN-15MIN SWO CNT(REG) MN 02000804 SWO PROC TCN-15MIN F SYNC ALM DUR(REG) MN 02000805 SWO PROC TCN-15MIN BER ALM DUR(REG) MN 02000807 SWO PROC TCN-15MIN F SYNC ALM CNT(REG) MN 02000808 SWO PROC TCN-15MIN BER ALM CNT(REG) MN 02000905 SWO PROC TCN-1DAY SWO FAIL DUR(REG) MN 02000906 SWO PROC TCN-1DAY SWO DUR(REG) MN 02000907 SWO PROC TCN-1DAY SWO FAIL CNT(REG) MN 02000908 SWO PROC TCN-1DAY SWO CNT(REG) MN 02000A04 SWO PROC TCN-1DAY F SYNC ALM DUR(REG) MN 02000A05 SWO PROC TCN-1DAY BER ALM DUR(REG) MN

Page 38: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 38

HEX Module Alarm Text Level 02000A07 SWO PROC TCN-1DAY F SYNC ALM CNT(REG) MN 02000A08 SWO PROC TCN-1DAY BER ALM CNT(REG) MN 02010101 SWO PROC F SYNC ALM(PROT) MJ 02010102 SWO PROC BER ALM(PROT) MJ 02010104 SWO PROC RCVY(PROT) ST1 02010105 SWO PROC TX SW CMPL(PROT) ST1 02010106 SWO PROC SVCE FAIL(PROT) CR 02010107 SWO PROC PPF(PROT) MJ 02010203 SWO PROC TX ACS SW ANS(PROT) ST1 02010204 SWO PROC RX ACS SW ANS(PROT) ST1 02010208 SWO PROC INTF ALM(PROT) MJ 02010301 SWO PROC TX ACS OP STS(PROT) ST1 02010303 SWO PROC LOCK OP STS(PROT) ST1 02010305 SWO PROC HL SW OP STS ST2 02010308 SWO PROC COUNT STOP(PROT) ST1 02010501 SWO PROC F SYNC ALM I(PROT) MJ 02010502 SWO PROC BER ALM I(PROT) MJ 02010505 SWO PROC TX CMPL I(PROT) ST1 02010705 SWO PROC TCN-15MIN SWO FAIL DUR(PROT) MN 02010706 SWO PROC TCN-15MIN SWO DUR(PROT) MN 02010707 SWO PROC TCN-15MIN SWO FAIL CNT(PROT) MN 02010708 SWO PROC TCN-15MIN SWO CNT(PROT) MN 02010804 SWO PROC TCN-15MIN F SYNC ALM DUR(PROT) MN 02010805 SWO PROC TCN-15MIN BER ALM DUR(PROT) MN 02010807 SWO PROC TCN-15MIN F SYNC ALM CNT(PROT) MN 02010808 SWO PROC TCN-15MIN BER ALM CNT(PROT) MN 02010905 SWO PROC TCN-1DAY SWO FAIL DUR(PROT) MN 02010906 SWO PROC TCN-1DAY SWO DUR(PROT) MN 02010907 SWO PROC TCN-1DAY SWO FAIL CNT(PROT) MN 02010908 SWO PROC TCN-1DAY SWO CNT(PROT) MN 02010A04 SWO PROC TCN-1DAY F SYNC ALM DUR(PROT) MN 02010A05 SWO PROC TCN-1DAY BER ALM DUR(PROT) MN 02010A07 SWO PROC TCN-1DAY F SYNC ALM CNT(PROT) MN 02010A08 SWO PROC TCN-1DAY BER ALM CNT(PROT) MN 02410001 SWO PROC Switching Count ST1 02410002 SWO PROC Switching Fail Count ST1 02410003 SWO PROC Switching Duration ST1 02410004 SWO PROC SWO EXP2 FAIL MJ 02410005 SWO PROC SWO EXP1 FAIL MJ 02410006 SWO PROC SWO EXP2 LINK OK(COM) ST2 02410007 SWO PROC SWO EXP1 LINK OK(COM) ST2 02410204 SWO PROC *MANUAL EXER. ST1 02410205 SWO PROC *EXER. OK ST1 02410206 SWO PROC COUNTER RESET(COM) ST1 02410303 SWO PROC SC FAIL(COM) MJ 02410304 SWO PROC SWO FAIL(COM) MJ 02410305 SWO PROC PREV SECT FAIL(COM) MJ

Page 39: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 39

HEX Module Alarm Text Level 02410306 SWO PROC PREV SECT MNL(COM) ST1 02410404 SWO PROC SWO AUTO(COM) ST1 02410407 SWO PROC PREV SECT EXER(COM) ST1 02410506 SWO PROC SC B ALM(COM) MJ 02410507 SWO PROC SC A ALM(COM) MJ 02410605 SWO PROC SC SEL(COM) ST2 02410606 SWO PROC SC TST OP(COM) ST1 02410608 SWO PROC SC AUTO/MANUAL OP(COM) ST1 02410701 SWO PROC EXER RUNNING(COM) ST1 02410702 SWO PROC AUTO EXER STOP(COM) ST1 02410801 SWO PROC ED(COM) ST1 02410802 SWO PROC PROT ALM(COM) MJ 02410803 SWO PROC REG ALM(COM) MJ 02410804 SWO PROC PREV SECT EXER I(COM) ST1 02410805 SWO PROC PREV SECT FAIL I(COM) MJ 02410806 SWO PROC PREV SECT MNL(COM) ST1 02410807 SWO PROC LOCK MNL(COM) ST1 02410808 SWO PROC EXER ALM(COM) MJ 02410B05 SWO PROC TCN-15MIN SWO FAIL DUR(COM) MN 02410B06 SWO PROC TCN-15MIN SWO DUR(COM) MN 02410B07 SWO PROC TCN-15MIN SWO FAIL CNT(COM) MN 02410B08 SWO PROC TCN-15MIN SWO CNT(COM) MN 02410D05 SWO PROC TCN-1DAY SWO FAIL DUR(COM) MN 02410D06 SWO PROC TCN-1DAY SWO DUR(COM) MN 02410D07 SWO PROC TCN-1DAY SWO FAIL CNT(COM) MN 02410D08 SWO PROC TCN-1DAY SWO CNT(COM) MN 04000001 ACL ACCESS FAILURE MJ 04000005 ACL System Data Missing MJ 04000007 ACL Remote Access Failure ST1 04000008 ACL Confidence Check Executing ST1 04000009 ACL System Config Data Missing MJ 04000101 CONTACTS CONTACT_1 MJ 04000102 CONTACTS CONTACT_2 MJ 04000103 CONTACTS CONTACT_3 MJ 04000104 CONTACTS CONTACT_4 MJ 04000105 CONTACTS CONTACT_5 MJ 04000106 CONTACTS CONTACT_6 MJ 04000107 CONTACTS CONTACT_7 MJ 04000108 CONTACTS CONTACT_8 MJ 04000109 CONTACTS CONTACT_9 MJ 0400010A CONTACTS CONTACT_10 MJ 0400010B CONTACTS CONTACT_11 MJ 0400010C CONTACTS CONTACT_12 MJ 0400010D CONTACTS CONTACT_13 MJ 0400010E CONTACTS CONTACT_14 MJ 0400010F CONTACTS CONTACT_15 MJ 04000110 CONTACTS CONTACT_16 MJ

Page 40: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 40

HEX Module Alarm Text Level 04000111 CONTACTS CONTACT_17 MJ 04000112 CONTACTS CONTACT_18 MJ 04000113 CONTACTS CONTACT_19 MJ 04000114 CONTACTS CONTACT_20 MJ 04000115 CONTACTS CONTACT_21 MJ 04000116 CONTACTS CONTACT_22 MJ 04000117 CONTACTS CONTACT_23 MJ 04000118 CONTACTS CONTACT_24 MJ 04000119 CONTACTS CONTACT_25 MJ 0400011A CONTACTS CONTACT_26 MJ 0400011B CONTACTS CONTACT_27 MJ 0400011C CONTACTS CONTACT_28 MJ 0400011D CONTACTS CONTACT_29 MJ 0400011E CONTACTS CONTACT_30 MJ 0400011F CONTACTS CONTACT_31 MJ 04000120 CONTACTS CONTACT_32 MJ 04008001 LMS Disconnect Status MN 04008002 LMS TSAP Duplication MN 04008003 LMS Unknown Address MN 04008004 LMS TP4 Connection Error MN 04008005 LMS Communication Failure MN 04008006 LMS TP4 Function Error MN 04008007 LMS Receive Buffer Set Error MN 04010001 ACL NO RESPONSE MJ 04010002 ACL UNIT FAIL MJ

Page 41: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 41

Appendix D – System3000 Radio Alarms

HEX Module Alarm Text Level 01010000 MODEM PANEL SERVICE STATE ST1 01010003 MODEM MODULE TYPE MISMATCH MJ 01010007 MODEM MODEM UNEQUIPPED ALM MJ 01010100 MODEM INPUT LEVEL DOWN MJ 01010103 MODEM OUTPUT LEVEL DOWN MJ 01010104 MODEM ENCODE FAILURE MJ 01010205 MODEM LOSS OF FRAME MJ 01010206 MODEM OUT OF FRAME MJ 01010300 MODEM OUT OF SERVICE(SW POSITION) ST1 01010303 MODEM FRAME SYNC LOSS MJ 01010305 MODEM XPIC ALM MJ 01010307 MODEM XPIC RESET ST1 01010400 MODEM SECTION LOW BER ALM MN 01010401 MODEM SECTION HIGH BER ALM MJ 01010402 MODEM HOP LOW BER ALM MN 01010403 MODEM HOP HIGH BER ALM MJ 01010404 MODEM SIGNAL DEGRADE(B1) MN 01010405 MODEM EXCESSIVE BER(B1) MJ 01010407 MODEM EARLY WARNING MN 01010507 MODEM LOOP BACK OPERATION[DMR SIDE] ST1 01010604 MODEM TRACE(J0) MISMATCH MJ 01010700 MODEM TCN-15MIN OFS MN 01010701 MODEM TCN-15MIN B1 BBE MN 01010702 MODEM TCN-15MIN B1 ES MN 01010703 MODEM TCN-15MIN B1 SES MN 01010704 MODEM TCN-15MIN B1 UAS MN 01010800 MODEM TCN-1DAY OFS MN 01010801 MODEM TCN-1DAY B1 BBE MN 01010802 MODEM TCN-1DAY B1 ES MN 01010803 MODEM TCN-1DAY B1 SES MN 01010804 MODEM TCN-1DAY B1 UAS MN 01020000 WS INTFC PANEL SERVICE STATE ST1 01020003 WS INTFC MODULE TYPE MISMATCH MJ 01020007 WS INTFC WS INTFC UNEQUIPPED ALM MJ 01020200 WS INTFC WS INTFC ALM MJ 01020201 WS INTFC STBY CH ALM MJ 01020204 WS INTFC PROT CH SELECTED ST2 010202A2 WS INTFC REG CH FRAME SYNC ALM MJ 010202A3 WS INTFC PROT CH FRAME SYNC ALM MJ 010202C2 WS INTFC WS1 FRAME SYNC ALM MJ 010202C3 WS INTFC WS2 FRAME SYNC ALM MJ 010202D2 WS INTFC WS1/2 FRAME SYNC ALM MJ 010202D3 WS INTFC WS3/4 FRAME SYNC ALM MJ

Page 42: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 42

HEX Module Alarm Text Level 010203A4 WS INTFC REG CH BER ALM MJ 010203A5 WS INTFC PROT CH BER ALM MJ 010203C4 WS INTFC WS1 BER ALM MJ 010203C5 WS INTFC WS2 BER ALM MJ 010203D4 WS INTFC WS1/2 BER ALM MJ 010203D5 WS INTFC WS3/4 BER ALM MJ 010204A1 WS INTFC WS1 REG CH RX ALM MJ 010204A3 WS INTFC WS1 PROT CH RX ALM MJ 010204A5 WS INTFC WS1 REG CH TX ALM MJ 010204A7 WS INTFC WS1 PROT CH TX ALM MJ 010204B0 WS INTFC WS2 REG CH RX ALM MJ 010204B2 WS INTFC WS2 PROT CH RX ALM MJ 010204B4 WS INTFC WS2 REG CH TX ALM MJ 010204B6 WS INTFC WS2 PROT CH TX ALM MJ 010204C1 WS INTFC WS1 RX ALM MJ 010204C3 WS INTFC WS2 RX ALM MJ 010204C5 WS INTFC WS1 TX ALM MJ 010204C7 WS INTFC WS2 TX ALM MJ 010204D0 WS INTFC WS2 RX ALM MJ 010204D1 WS INTFC WS1 RX ALM MJ 010204D2 WS INTFC WS4 RX ALM MJ 010204D3 WS INTFC WS3 RX ALM MJ 010204D4 WS INTFC WS2 TX ALM MJ 010204D5 WS INTFC WS1 TX ALM MJ 010204D6 WS INTFC WS4 TX ALM MJ 010204D7 WS INTFC WS3 TX ALM MJ 01020502 WS INTFC WS4 AIS SEND ST1 01020506 WS INTFC WS4 AIS RCVD ST1 010205A1 WS INTFC WS1 AIS SEND ST1 010205A5 WS INTFC WS1 AIS RCVD ST1 010205B0 WS INTFC WS2 AIS SEND ST1 010205B4 WS INTFC WS2 AIS RCVD ST1 010205C1 WS INTFC WS1 AIS SEND ST1 010205C3 WS INTFC WS2 AIS SEND ST1 010205C5 WS INTFC WS1 AIS RCVD ST1 010205C7 WS INTFC WS2 AIS RCVD ST1 010205D0 WS INTFC WS2 AIS SEND ST1 010205D1 WS INTFC WS1 AIS SEND ST1 010205D3 WS INTFC WS3 AIS SEND ST1 010205D4 WS INTFC WS2 AIS RCVD ST1 010205D5 WS INTFC WS1 AIS RCVD ST1 010205D7 WS INTFC WS3 AIS RCVD ST1 01100000 OPT INTFC PANEL SERVICE STATE ST1 01100003 OPT INTFC MODULE TYPE MISMATCH MJ 01100007 OPT INTFC OPT INTFC UNEQUIPPED ALM MJ 01100201 OPT INTFC HL SW OPERATION ST2 01100202 OPT INTFC OUT OF FRAME ON REG MJ

Page 43: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 43

HEX Module Alarm Text Level 01100203 OPT INTFC OUT OF FRAME ON PROT ST1 01100305 OPT INTFC REG DELAY MATCHED WITH PROT ST2 01100306 OPT INTFC INPHASE ST2 01100400 OPT INTFC LOOP BACK OPERATION[DMR SIDE] ST1 01100401 OPT INTFC LOOP BACK OPERATION[MUX SIDE] ST1 01100500 OPT INTFC RS TRACE(J0) MISMATCH [FROM DMR] MJ 01100501 OPT INTFC RS TRACE(J0) MISMATCH [FROM MUX] MJ 01100700 OPT INTFC MS-RDI(MS-FERF) RECEIVED [FROM MUX] ST1 01100701 OPT INTFC MS-AIS RECEIVED [FROM MUX] ST1 01100702 OPT INTFC SIGNAL DEGRADE(B2) [FROM MUX] MN 01100703 OPT INTFC EXCESSIVE BER(B2) [FROM MUX] MJ 01100704 OPT INTFC SIGNAL DEGRADE(B1) [FROM MUX] MN 01100706 OPT INTFC LOSS OF FRAME [FROM MUX] MJ 01100707 OPT INTFC LOSS OF SIGNAL [FROM MUX] MJ 01100902 OPT INTFC AU PATH AIS3 RECEIVED [FROM MUX] ST1 01100903 OPT INTFC AU PATH AIS2 RECEIVED [FROM MUX] ST1 01100904 OPT INTFC AU PATH AIS1 RECEIVED [FROM MUX] ST1 01100905 OPT INTFC LOSS OF POINTER3 [FROM MUX] MJ 01100906 OPT INTFC LOSS OF POINTER2 [FROM MUX] MJ 01100907 OPT INTFC LOSS OF POINTER1 [FROM MUX] MJ 01100A02 OPT INTFC EXCESSIVE BER3(B3) [FROM MUX] MJ 01100A03 OPT INTFC EXCESSIVE BER2(B3) [FROM MUX] MJ 01100A04 OPT INTFC EXCESSIVE BER1(B3) [FROM MUX] MJ 01100B06 OPT INTFC LD BIAS ALM MJ 01100B07 OPT INTFC LOSS OF OUTPUT [TO MUX] MJ 01100C00 OPT INTFC MS-RDI(MS-FERF) RECEIVED [FROM DMR] ST1 01100C01 OPT INTFC MS-AIS RECEIVED [FROM DMR] ST1 01100C02 OPT INTFC SIGNAL DEGRADE(B2) [FROM DMR] MN 01100C03 OPT INTFC EXCESSIVE BER(B2) [FROM DMR] MJ 01100C04 OPT INTFC SIGNAL DEGRADE(B1) [FROM DMR] MN 01100C05 OPT INTFC EXCESSIVE BER(B1) [FROM DMR] MJ 01100C06 OPT INTFC LOSS OF FRAME [FROM DMR] MJ 01100C07 OPT INTFC LOSS OF SIGNAL [FROM DMR] MJ 01100E02 OPT INTFC AU PATH AIS3 RECEIVED [FROM DMR] ST1 01100E03 OPT INTFC AU PATH AIS2 RECEIVED [FROM DMR] ST1 01100E04 OPT INTFC AU PATH AIS1 RECEIVED [FROM DMR] ST1 01100E05 OPT INTFC LOSS OF POINTER3 [FROM DMR] MJ 01100E06 OPT INTFC LOSS OF POINTER2 [FROM DMR] MJ 01100E07 OPT INTFC LOSS OF POINTER1 [FROM DMR] MJ 01100F02 OPT INTFC EXCESSIVE BER3(B3) [FROM DMR] MJ 01100F03 OPT INTFC EXCESSIVE BER2(B3) [FROM DMR] MJ 01100F04 OPT INTFC EXCESSIVE BER1(B3) [FROM DMR] MJ 01101005 OPT INTFC OPT INTFC ALM MJ 01101100 OPT INTFC ALS IMPLEMENTED ST1 01101300 OPT INTFC TCN-15MIN OFS [FROM MUX] MN 01101301 OPT INTFC TCN-15MIN NBBE(B1) [FROM MUX] MN 01101302 OPT INTFC TCN-15MIN NES(B1) [FROM MUX] MN

Page 44: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 44

HEX Module Alarm Text Level 01101303 OPT INTFC TCN-15MIN NSES(B1) [FROM MUX] MN 01101304 OPT INTFC TCN-15MIN NBBE(B2) [FROM MUX] MN 01101305 OPT INTFC TCN-15MIN NES(B2) [FROM MUX] MN 01101306 OPT INTFC TCN-15MIN NSES(B2) [FROM MUX] MN 01101307 OPT INTFC TCN-15MIN FBBE(M1) [FROM MUX] MN 01101400 OPT INTFC TCN-15MIN FES(M1) [FROM MUX] MN 01101401 OPT INTFC TCN-15MIN FSES(M1) [FROM MUX] MN 01101402 OPT INTFC TCN-15MIN NUAS(B1) [FROM MUX] MN 01101403 OPT INTFC TCN-15MIN NUAS(B2) [FROM MUX] MN 01101404 OPT INTFC TCN-15MIN FUAS(M1) [FROM MUX] MN 01101405 OPT INTFC TCN-15MIN P-PJE1 [FROM MUX] MN 01101406 OPT INTFC TCN-15MIN N-PJE1 [FROM MUX] MN 01101407 OPT INTFC TCN-15MIN P-PJE2 [FROM MUX] MN 01101500 OPT INTFC TCN-15MIN N-PJE2 [FROM MUX] MN 01101501 OPT INTFC TCN-15MIN P-PJE3 [FROM MUX] MN 01101502 OPT INTFC TCN-15MIN N-PJE3 [FROM MUX] MN 01101503 OPT INTFC TCN-15MIN OFS [FROM DMR] MN 01101504 OPT INTFC TCN-15MIN NBBE(B1) [FROM DMR] MN 01101505 OPT INTFC TCN-15MIN NES(B1) [FROM DMR] MN 01101506 OPT INTFC TCN-15MIN NSES(B1) [FROM DMR] MN 01101507 OPT INTFC TCN-15MIN NBBE(B2) [FROM DMR] MN 01101600 OPT INTFC TCN-15MIN NES(B2) [FROM DMR] MN 01101601 OPT INTFC TCN-15MIN NSES(B2) [FROM DMR] MN 01101602 OPT INTFC TCN-15MIN FBBE(M1) [FROM DMR] MN 01101603 OPT INTFC TCN-15MIN FES(M1) [FROM DMR] MN 01101604 OPT INTFC TCN-15MIN FSES(M1) [FROM DMR] MN 01101605 OPT INTFC TCN-15MIN NUAS(B1) [FROM DMR] MN 01101606 OPT INTFC TCN-15MIN NUAS(B2) [FROM DMR] MN 01101607 OPT INTFC TCN-15MIN FUAS(M1) [FROM DMR] MN 01101700 OPT INTFC TCN-15MIN P-PJE1 [FROM DMR] MN 01101701 OPT INTFC TCN-15MIN N-PJE1 [FROM DMR] MN 01101702 OPT INTFC TCN-15MIN P-PJE2 [FROM DMR] MN 01101703 OPT INTFC TCN-15MIN N-PJE2 [FROM DMR] MN 01101704 OPT INTFC TCN-15MIN P-PJE3 [FROM DMR] MN 01101705 OPT INTFC TCN-15MIN N-PJE3 [FROM DMR] MN 01101900 OPT INTFC TCN-1DAY OFS [FROM MUX] MN 01101901 OPT INTFC TCN-1DAY NBBE(B1) [FROM MUX] MN 01101902 OPT INTFC TCN-1DAY NES(B1) [FROM MUX] MN 01101903 OPT INTFC TCN-1DAY NSES(B1) [FROM MUX] MN 01101904 OPT INTFC TCN-1DAY NBBE(B2) [FROM MUX] MN 01101905 OPT INTFC TCN-1DAY NES(B2) [FROM MUX] MN 01101906 OPT INTFC TCN-1DAY NSES(B2) [FROM MUX] MN 01101907 OPT INTFC TCN-1DAY FBBE(M1) [FROM MUX] MN 01101A00 OPT INTFC TCN-1DAY FES(M1) [FROM MUX] MN 01101A01 OPT INTFC TCN-1DAY FSES(M1) [FROM MUX] MN 01101A02 OPT INTFC TCN-1DAY NUAS(B1) [FROM MUX] MN 01101A03 OPT INTFC TCN-1DAY NUAS(B2) [FROM MUX] MN

Page 45: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 45

HEX Module Alarm Text Level 01101A04 OPT INTFC TCN-1DAY FUAS(M1) [FROM MUX] MN 01101A05 OPT INTFC TCN-1DAY P-PJE1 [FROM MUX] MN 01101A06 OPT INTFC TCN-1DAY N-PJE1 [FROM MUX] MN 01101A07 OPT INTFC TCN-1DAY P-PJE2 [FROM MUX] MN 01101B00 OPT INTFC TCN-1DAY N-PJE2 [FROM MUX] MN 01101B01 OPT INTFC TCN-1DAY P-PJE3 [FROM MUX] MN 01101B02 OPT INTFC TCN-1DAY N-PJE3 [FROM MUX] MN 01101B03 OPT INTFC TCN-1DAY OFS [FROM DMR] MN 01101B04 OPT INTFC TCN-1DAY NBBE(B1) [FROM DMR] MN 01101B05 OPT INTFC TCN-1DAY NES(B1) [FROM DMR] MN 01101B06 OPT INTFC TCN-1DAY NSES(B1) [FROM DMR] MN 01101B07 OPT INTFC TCN-1DAY NBBE(B2) [FROM DMR] MN 01101C00 OPT INTFC TCN-1DAY NES(B2) [FROM DMR] MN 01101C01 OPT INTFC TCN-1DAY NSES(B2) [FROM DMR] MN 01101C02 OPT INTFC TCN-1DAY FBBE(M1) [FROM DMR] MN 01101C03 OPT INTFC TCN-1DAY FES(M1) [FROM DMR] MN 01101C04 OPT INTFC TCN-1DAY FSES(M1) [FROM DMR] MN 01101C05 OPT INTFC TCN-1DAY NUAS(B1) [FROM DMR] MN 01101C06 OPT INTFC TCN-1DAY NUAS(B2) [FROM DMR] MN 01101C07 OPT INTFC TCN-1DAY FUAS(M1) [FROM DMR] MN 01101D00 OPT INTFC TCN-1DAY P-PJE1 [FROM DMR] MN 01101D01 OPT INTFC TCN-1DAY N-PJE1 [FROM DMR] MN 01101D02 OPT INTFC TCN-1DAY P-PJE2 [FROM DMR] MN 01101D03 OPT INTFC TCN-1DAY N-PJE2 [FROM DMR] MN 01101D04 OPT INTFC TCN-1DAY P-PJE3 [FROM DMR] MN 01101D05 OPT INTFC TCN-1DAY N-PJE3 [FROM DMR] MN 01110000 150M INTFC PANEL SERVICE STATE ST1 01110003 150M INTFC MODULE TYPE MISMATCH MJ 01110007 150M INTFC 150M INTFC UNEQUIPPED ALM MJ 01110201 150M INTFC HL SW OPERATION ST2 01110202 150M INTFC OUT OF FRAME ON REG MJ 01110203 150M INTFC OUT OF FRAME ON PROT ST1 01110305 150M INTFC REG DELAY MATCHED WITH PROT ST2 01110306 150M INTFC INPHASE ST2 01110400 150M INTFC LOOP BACK OPERATION[DMR SIDE] ST1 01110401 150M INTFC LOOP BACK OPERATION[MUX SIDE] ST1 01110500 150M INTFC RS TRACE(J0) MISMATCH [FROM DMR] MJ 01110501 150M INTFC RS TRACE(J0) MISMATCH [FROM MUX] MJ 01110700 150M INTFC MS-RDI(MS-FERF) RECEIVED [FROM MUX] ST1 01110701 150M INTFC MS-AIS RECEIVED [FROM MUX] ST1 01110702 150M INTFC SIGNAL DEGRADE(B2) [FROM MUX] MN 01110703 150M INTFC EXCESSIVE BER(B2) [FROM MUX] MJ 01110704 150M INTFC SIGNAL DEGRADE(B1) [FROM MUX] MN 01110706 150M INTFC LOSS OF FRAME [FROM MUX] MJ 01110707 150M INTFC LOSS OF SIGNAL [FROM MUX] MJ 01110902 150M INTFC AU PATH AIS3 RECEIVED [FROM MUX] ST1 01110903 150M INTFC AU PATH AIS2 RECEIVED [FROM MUX] ST1

Page 46: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 46

HEX Module Alarm Text Level 01110904 150M INTFC AU PATH AIS1 RECEIVED [FROM MUX] ST1 01110905 150M INTFC LOSS OF POINTER3 [FROM MUX] MJ 01110906 150M INTFC LOSS OF POINTER2 [FROM MUX] MJ 01110907 150M INTFC LOSS OF POINTER1 [FROM MUX] MJ 01110A02 150M INTFC EXCESSIVE BER3(B3) [FROM MUX] MJ 01110A03 150M INTFC EXCESSIVE BER2(B3) [FROM MUX] MJ 01110A04 150M INTFC EXCESSIVE BER1(B3) [FROM MUX] MJ 01110B07 150M INTFC LOSS OF OUTPUT [TO MUX] MJ 01110C00 150M INTFC MS-RDI(MS-FERF) RECEIVED [FROM DMR] ST1 01110C01 150M INTFC MS-AIS RECEIVED [FROM DMR] ST1 01110C02 150M INTFC SIGNAL DEGRADE(B2) [FROM DMR] MN 01110C03 150M INTFC EXCESSIVE BER(B2) [FROM DMR] MJ 01110C04 150M INTFC SIGNAL DEGRADE(B1) [FROM DMR] MN 01110C05 150M INTFC EXCESSIVE BER(B1) [FROM DMR] MJ 01110C06 150M INTFC LOSS OF FRAME [FROM DMR] MJ 01110C07 150M INTFC LOSS OF SIGNAL [FROM DMR] MJ 01110E02 150M INTFC AU PATH AIS3 RECEIVED [FROM DMR] ST1 01110E03 150M INTFC AU PATH AIS2 RECEIVED [FROM DMR] ST1 01110E04 150M INTFC AU PATH AIS1 RECEIVED [FROM DMR] ST1 01110E05 150M INTFC LOSS OF POINTER3 [FROM DMR] MJ 01110E06 150M INTFC LOSS OF POINTER2 [FROM DMR] MJ 01110E07 150M INTFC LOSS OF POINTER1 [FROM DMR] MJ 01110F02 150M INTFC EXCESSIVE BER3(B3) [FROM DMR] MJ 01110F03 150M INTFC EXCESSIVE BER2(B3) [FROM DMR] MJ 01110F04 150M INTFC EXCESSIVE BER1(B3) [FROM DMR] MJ 01111005 150M INTFC 150M INTFC ALM MJ 01111300 150M INTFC TCN-15MIN OFS [FROM MUX] MN 01111301 150M INTFC TCN-15MIN NBBE(B1) [FROM MUX] MN 01111302 150M INTFC TCN-15MIN NES(B1) [FROM MUX] MN 01111303 150M INTFC TCN-15MIN NSES(B1) [FROM MUX] MN 01111304 150M INTFC TCN-15MIN NBBE(B2) [FROM MUX] MN 01111305 150M INTFC TCN-15MIN NES(B2) [FROM MUX] MN 01111306 150M INTFC TCN-15MIN NSES(B2) [FROM MUX] MN 01111307 150M INTFC TCN-15MIN FBBE(M1) [FROM MUX] MN 01111400 150M INTFC TCN-15MIN FES(M1) [FROM MUX] MN 01111401 150M INTFC TCN-15MIN FSES(M1) [FROM MUX] MN 01111402 150M INTFC TCN-15MIN NUAS(B1) [FROM MUX] MN 01111403 150M INTFC TCN-15MIN NUAS(B2) [FROM MUX] MN 01111404 150M INTFC TCN-15MIN FUAS(M1) [FROM MUX] MN 01111405 150M INTFC TCN-15MIN P-PJE1 [FROM MUX] MN 01111406 150M INTFC TCN-15MIN N-PJE1 [FROM MUX] MN 01111407 150M INTFC TCN-15MIN P-PJE2 [FROM MUX] MN 01111500 150M INTFC TCN-15MIN N-PJE2 [FROM MUX] MN 01111501 150M INTFC TCN-15MIN P-PJE3 [FROM MUX] MN 01111502 150M INTFC TCN-15MIN N-PJE3 [FROM MUX] MN 01111503 150M INTFC TCN-15MIN OFS [FROM DMR] MN 01111504 150M INTFC TCN-15MIN NBBE(B1) [FROM DMR] MN

Page 47: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 47

HEX Module Alarm Text Level 01111505 150M INTFC TCN-15MIN NES(B1) [FROM DMR] MN 01111506 150M INTFC TCN-15MIN NSES(B1) [FROM DMR] MN 01111507 150M INTFC TCN-15MIN NBBE(B2) [FROM DMR] MN 01111600 150M INTFC TCN-15MIN NES(B2) [FROM DMR] MN 01111601 150M INTFC TCN-15MIN NSES(B2) [FROM DMR] MN 01111602 150M INTFC TCN-15MIN FBBE(M1) [FROM DMR] MN 01111603 150M INTFC TCN-15MIN FES(M1) [FROM DMR] MN 01111604 150M INTFC TCN-15MIN FSES(M1) [FROM DMR] MN 01111605 150M INTFC TCN-15MIN NUAS(B1) [FROM DMR] MN 01111606 150M INTFC TCN-15MIN NUAS(B2) [FROM DMR] MN 01111607 150M INTFC TCN-15MIN FUAS(M1) [FROM DMR] MN 01111700 150M INTFC TCN-15MIN P-PJE1 [FROM DMR] MN 01111701 150M INTFC TCN-15MIN N-PJE1 [FROM DMR] MN 01111702 150M INTFC TCN-15MIN P-PJE2 [FROM DMR] MN 01111703 150M INTFC TCN-15MIN N-PJE2 [FROM DMR] MN 01111704 150M INTFC TCN-15MIN P-PJE3 [FROM DMR] MN 01111705 150M INTFC TCN-15MIN N-PJE3 [FROM DMR] MN 01111900 150M INTFC TCN-1DAY OFS [FROM MUX] MN 01111901 150M INTFC TCN-1DAY NBBE(B1) [FROM MUX] MN 01111902 150M INTFC TCN-1DAY NES(B1) [FROM MUX] MN 01111903 150M INTFC TCN-1DAY NSES(B1) [FROM MUX] MN 01111904 150M INTFC TCN-1DAY NBBE(B2) [FROM MUX] MN 01111905 150M INTFC TCN-1DAY NES(B2) [FROM MUX] MN 01111906 150M INTFC TCN-1DAY NSES(B2) [FROM MUX] MN 01111907 150M INTFC TCN-1DAY FBBE(M1) [FROM MUX] MN 01111A00 150M INTFC TCN-1DAY FES(M1) [FROM MUX] MN 01111A01 150M INTFC TCN-1DAY FSES(M1) [FROM MUX] MN 01111A02 150M INTFC TCN-1DAY NUAS(B1) [FROM MUX] MN 01111A03 150M INTFC TCN-1DAY NUAS(B2) [FROM MUX] MN 01111A04 150M INTFC TCN-1DAY FUAS(M1) [FROM MUX] MN 01111A05 150M INTFC TCN-1DAY P-PJE1 [FROM MUX] MN 01111A06 150M INTFC TCN-1DAY N-PJE1 [FROM MUX] MN 01111A07 150M INTFC TCN-1DAY P-PJE2 [FROM MUX] MN 01111B00 150M INTFC TCN-1DAY N-PJE2 [FROM MUX] MN 01111B01 150M INTFC TCN-1DAY P-PJE3 [FROM MUX] MN 01111B02 150M INTFC TCN-1DAY N-PJE3 [FROM MUX] MN 01111B03 150M INTFC TCN-1DAY OFS [FROM DMR] MN 01111B04 150M INTFC TCN-1DAY NBBE(B1) [FROM DMR] MN 01111B05 150M INTFC TCN-1DAY NES(B1) [FROM DMR] MN 01111B06 150M INTFC TCN-1DAY NSES(B1) [FROM DMR] MN 01111B07 150M INTFC TCN-1DAY NBBE(B2) [FROM DMR] MN 01111C00 150M INTFC TCN-1DAY NES(B2) [FROM DMR] MN 01111C01 150M INTFC TCN-1DAY NSES(B2) [FROM DMR] MN 01111C02 150M INTFC TCN-1DAY FBBE(M1) [FROM DMR] MN 01111C03 150M INTFC TCN-1DAY FES(M1) [FROM DMR] MN 01111C04 150M INTFC TCN-1DAY FSES(M1) [FROM DMR] MN 01111C05 150M INTFC TCN-1DAY NUAS(B1) [FROM DMR] MN

Page 48: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 48

HEX Module Alarm Text Level 01111C06 150M INTFC TCN-1DAY NUAS(B2) [FROM DMR] MN 01111C07 150M INTFC TCN-1DAY FUAS(M1) [FROM DMR] MN 01111D00 150M INTFC TCN-1DAY P-PJE1 [FROM DMR] MN 01111D01 150M INTFC TCN-1DAY N-PJE1 [FROM DMR] MN 01111D02 150M INTFC TCN-1DAY P-PJE2 [FROM DMR] MN 01111D03 150M INTFC TCN-1DAY N-PJE2 [FROM DMR] MN 01111D04 150M INTFC TCN-1DAY P-PJE3 [FROM DMR] MN 01111D05 150M INTFC TCN-1DAY N-PJE3 [FROM DMR] MN 01120000 140M INTFC PANEL SERVICE STATE ST1 01120003 140M INTFC MODULE TYPE MISMATCH MJ 01120007 140M INTFC 140M INTFC UNEQUIPPED ALM MJ 01120201 140M INTFC HL SW OPERATION ST2 01120202 140M INTFC OUT OF FRAME ON REG MJ 01120203 140M INTFC OUT OF FRAME ON PROT ST1 01120305 140M INTFC REG DELAY MATCHED WITH PROT ST2 01120306 140M INTFC INPHASE ST2 01120A01 140M INTFC AIS RECEIVED [FROM MUX] ST1 01120A06 140M INTFC LOOP BACK OPERATION[MUX SIDE] ST1 01120A07 140M INTFC LOOP BACK OPERATION[DMR SIDE] ST1 01120B01 140M INTFC HO PATH FERF RECEIVED ST1 01120B02 140M INTFC HO PATH SIGNAL LABEL MISMATCH ST1 01120B03 140M INTFC HO PATH UNEQUIPPED RECEIVED ST1 01120B05 140M INTFC EXCESSIVE BER(B3) [FROM DMR] MJ 01120B06 140M INTFC 140M INTFC ALM(CPU/DDS) MJ 01120D00 140M INTFC PATH TRACE(J1) MISMATCH MJ 01120E07 140M INTFC LOSS OF SIGNAL [FROM MUX] MJ 01121207 140M INTFC LOSS OF OUTPUT [TO MUX] MJ 01121300 140M INTFC MS-RDI(MS-FERF) RECEIVED [FROM DMR] ST1 01121301 140M INTFC MS-AIS RECEIVED [FROM DMR] ST1 01121302 140M INTFC SIGNAL DEGRADE(B2) [FROM DMR] MN 01121303 140M INTFC EXCESSIVE BER(B2) [FROM DMR] MJ 01121306 140M INTFC LOSS OF FRAME [FROM DMR] MJ 01121307 140M INTFC LOSS OF SIGNAL [FROM DMR] MJ 01121504 140M INTFC AU PATH AIS1 RECEIVED [FROM DMR] ST1 01121507 140M INTFC LOSS OF POINTER1 [FROM DMR] MJ 01121602 140M INTFC EXCESSIVE BER3(B3)[FROM DMR] ST1 01121603 140M INTFC EXCESSIVE BER2(B3)[FROM DMR] ST1 01121604 140M INTFC EXCESSIVE BER1(B3)[FROM DMR] ST1 01121705 140M INTFC 140M INTFC ALM MJ 01121C07 140M INTFC TCN-15MIN NBBE(B2) [FROM DMR] MN 01121D00 140M INTFC TCN-15MIN NES(B2) [FROM DMR] MN 01121D01 140M INTFC TCN-15MIN NSES(B2) [FROM DMR] MN 01121D02 140M INTFC TCN-15MIN FBBE(M1) [FROM DMR] MN 01121D03 140M INTFC TCN-15MIN FES(M1) [FROM DMR] MN 01121D04 140M INTFC TCN-15MIN FSES(M1) [FROM DMR] MN 01121D06 140M INTFC TCN-15MIN NUAS(B2) [FROM DMR] MN 01121D07 140M INTFC TCN-15MIN FUAS(M1) [FROM DMR] MN

Page 49: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 49

HEX Module Alarm Text Level 01121E00 140M INTFC TCN-15MIN P-PJE1 [FROM DMR] MN 01121E01 140M INTFC TCN-15MIN N-PJE1 [FROM DMR] MN 01121F00 140M INTFC TCN-15MIN NBBE(B3) [FROM DMR] MN 01121F01 140M INTFC TCN-15MIN NES(B3) [FROM DMR] MN 01121F02 140M INTFC TCN-15MIN NSES(B3) [FROM DMR] MN 01121F03 140M INTFC TCN-15MIN NUAS(B3) [FROM DMR] MN 01121F04 140M INTFC TCN-15MIN FBBE(G1) [FROM DMR] MN 01121F05 140M INTFC TCN-15MIN FES(G1) [FROM DMR] MN 01121F06 140M INTFC TCN-15MIN FSES(G1) [FROM DMR] MN 01121F07 140M INTFC TCN-15MIN FUAS(G1) [FROM DMR] MN 01122207 140M INTFC TCN-1DAY NBBE(B2) [FROM DMR] MN 01122300 140M INTFC TCN-1DAY NES(B2) [FROM DMR] MN 01122301 140M INTFC TCN-1DAY NSES(B2) [FROM DMR] MN 01122302 140M INTFC TCN-1DAY FBBE(M1) [FROM DMR] MN 01122303 140M INTFC TCN-1DAY FES(M1) [FROM DMR] MN 01122304 140M INTFC TCN-1DAY FSES(M1) [FROM DMR] MN 01122306 140M INTFC TCN-1DAY NUAS(B2) [FROM DMR] MN 01122307 140M INTFC TCN-1DAY FUAS(M1) [FROM DMR] MN 01122400 140M INTFC TCN-1DAY P-PJE1 [FROM DMR] MN 01122401 140M INTFC TCN-1DAY N-PJE1 [FROM DMR] MN 01122500 140M INTFC TCN-1DAY NBBE(B3) [FROM DMR] MN 01122501 140M INTFC TCN-1DAY NES(B3) [FROM DMR] MN 01122502 140M INTFC TCN-1DAY NSES(B3) [FROM DMR] MN 01122503 140M INTFC TCN-1DAY NUAS(B3) [FROM DMR] MN 01122504 140M INTFC TCN-1DAY FBBE(G1) [FROM DMR] MN 01122505 140M INTFC TCN-1DAY FES(G1) [FROM DMR] MN 01122506 140M INTFC TCN-1DAY FSES(G1) [FROM DMR] MN 01122507 140M INTFC TCN-1DAY FUAS(G1) [FROM DMR] MN 01130000 TR DIST PANEL SERVICE STATE ST1 01130003 TR DIST MODULE TYPE MISMATCH MJ 01130007 TR DIST TR DIST UNEQUIPPED ALM MJ 01130200 TR DIST SYS1 TX SW OPERATION ST2 01130201 TR DIST SYS2 TX SW OPERATION ST2 01130202 TR DIST SYS3 TX SW OPERATION ST2 01130203 TR DIST SYS4 TX SW OPERATION ST2 01130403 TR DIST TR DIST ALM MJ 01130404 TR DIST AL INTFC ALM MJ 01130500 TR DIST TX PROT ACCESS OPERATION ST2 01130501 TR DIST RX PROT ACCESS OPERATION ST2 01140000 BB SW CTRL PANEL SERVICE STATE ST1 01140003 BB SW CTRL MODULE TYPE MISMATCH MJ 01140007 BB SW CTRL BB SW CTRL UNEQUIPPED ALM MJ 01140100 BB SW CTRL BB SW CTRL ALARM(UNIT FAIL) MJ 01140101 BB SW CTRL MSP CONTROL DISABLED ST1 01140200 BB SW CTRL SYS1 CHANNEL MISMATCH FAILURE MJ 01140201 BB SW CTRL SYS1 TYPE OF ARCHITECTURE FAILURE MJ 01140202 BB SW CTRL SYS1 TYPE OF DIRECTION FAILURE MJ

Page 50: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 50

HEX Module Alarm Text Level 01140203 BB SW CTRL SYS1 PROTECTION SWITCH BYTE FAILURE MJ 01140204 BB SW CTRL SYS1 FAR END PROTECTION LINE FAILURE MJ 01140205 BB SW CTRL SYS1 LOCK-IN ST2 01140300 BB SW CTRL SYS2 CHANNEL MISMATCH FAILURE MJ 01140301 BB SW CTRL SYS2 TYPE OF ARCHITECTURE FAILURE MJ 01140302 BB SW CTRL SYS2 TYPE OF DIRECTION FAILURE MJ 01140303 BB SW CTRL SYS2 PROTECTION SWITCH BYTE FAILURE MJ 01140304 BB SW CTRL SYS2 FAR END PROTECTION LINE FAILURE MJ 01140305 BB SW CTRL SYS2 LOCK-IN ST2 01140400 BB SW CTRL SYS3 CHANNEL MISMATCH FAILURE MJ 01140401 BB SW CTRL SYS3 TYPE OF ARCHITECTURE FAILURE MJ 01140402 BB SW CTRL SYS3 TYPE OF DIRECTION FAILURE MJ 01140403 BB SW CTRL SYS3 PROTECTION SWITCH BYTE FAILURE MJ 01140404 BB SW CTRL SYS3 FAR END PROTECTION LINE FAILURE MJ 01140405 BB SW CTRL SYS3 LOCK-IN ST2 01140500 BB SW CTRL SYS4 CHANNEL MISMATCH FAILURE MJ 01140501 BB SW CTRL SYS4 TYPE OF ARCHITECTURE FAILURE MJ 01140502 BB SW CTRL SYS4 TYPE OF DIRECTION FAILURE MJ 01140503 BB SW CTRL SYS4 PROTECTION SWITCH BYTE FAILURE MJ 01140504 BB SW CTRL SYS4 FAR END PROTECTION LINE FAILURE MJ 01140505 BB SW CTRL SYS4 LOCK-IN ST2 01140700 BB SW CTRL SYS1 EXERCISE FAILURE MJ 01140701 BB SW CTRL SYS1 SWITCHING FAILURE CR 01140702 BB SW CTRL SYS1 WORKING ONLINE ST2 01140703 BB SW CTRL SYS1 PROTECTION ONLINE ST2 01140704 BB SW CTRL SYS1 WORKING LINE SD MN 01140705 BB SW CTRL SYS1 PROTECTION LINE SD MN 01140706 BB SW CTRL SYS1 WORKING LINE SF MJ 01140707 BB SW CTRL SYS1 PROTECTION LINE SF MJ 01140902 BB SW CTRL SYS1 LOCAL EXERCISING ST2 01140904 BB SW CTRL SYS1 LOCAL WAIT TO RESTORE ST2 01140E00 BB SW CTRL SYS2 EXERCISE FAILURE MJ 01140E01 BB SW CTRL SYS2 SWITCHING FAILURE CR 01140E02 BB SW CTRL SYS2 WORKING ONLINE ST2 01140E03 BB SW CTRL SYS2 PROTECTION ONLINE ST2 01140E04 BB SW CTRL SYS2 WORKING LINE SD MN 01140E05 BB SW CTRL SYS2 PROTECTION LINE SD MN 01140E06 BB SW CTRL SYS2 WORKING LINE SF MJ 01140E07 BB SW CTRL SYS2 PROTECTION LINE SF MJ 01141002 BB SW CTRL SYS2 LOCAL EXERCISING ST2 01141004 BB SW CTRL SYS2 LOCAL WAIT TO RESTORE ST2 01141500 BB SW CTRL SYS3 EXERCISE FAILURE MJ 01141501 BB SW CTRL SYS3 SWITCHING FAILURE CR 01141502 BB SW CTRL SYS3 WORKING ONLINE ST2 01141503 BB SW CTRL SYS3 PROTECTION ONLINE ST2 01141504 BB SW CTRL SYS3 WORKING LINE SD MN 01141505 BB SW CTRL SYS3 PROTECTION LINE SD MN

Page 51: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 51

HEX Module Alarm Text Level 01141506 BB SW CTRL SYS3 WORKING LINE SF MJ 01141507 BB SW CTRL SYS3 PROTECTION LINE SF MJ 01141702 BB SW CTRL SYS3 LOCAL EXERCISING ST2 01141704 BB SW CTRL SYS3 LOCAL WAIT TO RESTORE ST2 01141C00 BB SW CTRL SYS4 EXERCISE FAILURE MJ 01141C01 BB SW CTRL SYS4 SWITCHING FAILURE CR 01141C02 BB SW CTRL SYS4 WORKING ONLINE ST2 01141C03 BB SW CTRL SYS4 PROTECTION ONLINE ST2 01141C04 BB SW CTRL SYS4 WORKING LINE SD MN 01141C05 BB SW CTRL SYS4 PROTECTION LINE SD MN 01141C06 BB SW CTRL SYS4 WORKING LINE SF MJ 01141C07 BB SW CTRL SYS4 PROTECTION LINE SF MJ 01141E02 BB SW CTRL SYS4 LOCAL EXERCISING ST2 01141E04 BB SW CTRL SYS4 LOCAL WAIT TO RESTORE ST2 01142300 BB SW CTRL TCN-15MIN PSD SYS4 MN 01142301 BB SW CTRL TCN-15MIN PSD SYS3 MN 01142302 BB SW CTRL TCN-15MIN PSD SYS2 MN 01142303 BB SW CTRL TCN-15MIN PSD SYS1 MN 01142304 BB SW CTRL TCN-15MIN PSC SYS4 MN 01142305 BB SW CTRL TCN-15MIN PSC SYS3 MN 01142306 BB SW CTRL TCN-15MIN PSC SYS2 MN 01142307 BB SW CTRL TCN-15MIN PSC SYS1 MN 01142400 BB SW CTRL TCN-1DAY PSD SYS4 MN 01142401 BB SW CTRL TCN-1DAY PSD SYS3 MN 01142402 BB SW CTRL TCN-1DAY PSD SYS2 MN 01142403 BB SW CTRL TCN-1DAY PSD SYS1 MN 01142404 BB SW CTRL TCN-1DAY PSC SYS4 MN 01142405 BB SW CTRL TCN-1DAY PSC SYS3 MN 01142406 BB SW CTRL TCN-1DAY PSC SYS2 MN 01142407 BB SW CTRL TCN-1DAY PSC SYS1 MN 01150000 CLK PANEL SERVICE STATE ST1 01150003 CLK MODULE TYPE MISMATCH MJ 01150007 CLK CLK UNEQUIPPED ALM MJ 01150200 CLK HOLD OVER MODE OPERATION ST1 01150201 CLK FREE RUN MODE OPERATION ST1 01150203 CLK SERVER SIGNAL FAIL MJ 01150300 CLK CLK MODULE ALARM MJ 01150304 CLK SQUELCHED EXTERNAL OUTPUT ST1 01150305 CLK EXTERNAL INPUT2 AIS RECEIVED ST1 01150306 CLK EXTERNAL INPUT1 AIS RECEIVED ST1 01150400 CLK LOSS OF SELECTED TIMING INPUT MJ 01150404 CLK EXTERNAL COMMAND REJECT(SOURCE) ST2 01150405 CLK EXTERNAL COMMAND REJECT(ONLINE) ST2 01150407 CLK CLK ONLINE ST2 01150CD0 CLK DMR1=SYS2 DMR2=SYS3 SELECTED FOR SOURCE ST2 01150CD1 CLK DMR1=SYS1 DMR2=SYS3 SELECTED FOR SOURCE ST2 01150CD2 CLK DMR1=SYS1 DMR2=SYS2 SELECTED FOR SOURCE ST2

Page 52: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 52

HEX Module Alarm Text Level 01150CD4 CLK MUX1=SYS2 MUX2=SYS3 SELECTED FOR SOURCE ST2 01150CD5 CLK MUX1=SYS1 MUX2=SYS3 SELECTED FOR SOURCE ST2 01150CD6 CLK MUX1=SYS1 MUX2=SYS2 SELECTED FOR SOURCE ST2 01150CE0 CLK DMR1=REG2 DMR2=REG3 SELECTED FOR SOURCE ST2 01150CE1 CLK DMR1=REG1 DMR2=REG3 SELECTED FOR SOURCE ST2 01150CE2 CLK DMR1=REG1 DMR2=REG2 SELECTED FOR SOURCE ST2 01150CE4 CLK MUX1=REG2 MUX2=REG3 SELECTED FOR SOURCE ST2 01150CE5 CLK MUX1=REG1 MUX2=REG3 SELECTED FOR SOURCE ST2 01150CE6 CLK MUX1=REG1 MUX2=REG2 SELECTED FOR SOURCE ST2 01150D02 CLK EXT2 INPUT SIGNAL AVAILABLE ST2 01150D03 CLK EXT1 INPUT SIGNAL AVAILABLE ST2 01150D04 CLK DMR2 SLAVE CLOCK AVAILABLE ST2 01150D05 CLK DMR1 SLAVE CLOCK AVAILABLE ST2 01150D06 CLK MUX2 SLAVE CLOCK AVAILABLE ST2 01150D07 CLK MUX1 SLAVE CLOCK AVAILABLE ST2 01150E00 CLK INPUT SIGNAL FAIL MJ 01150E02 CLK EXT2 INPUT SIGNAL FAIL MJ 01150E03 CLK EXT1 INPUT SIGNAL FAIL MJ 01150E04 CLK DMR2 SLAVE CLOCK SIGNAL FAIL MJ 01150E05 CLK DMR1 SLAVE CLOCK SIGNAL FAIL MJ 01150E06 CLK MUX2 SLAVE CLOCK SIGNAL FAIL MJ 01150E07 CLK MUX1 SLAVE CLOCK SIGNAL FAIL MJ 01150F00 CLK SLAVE CLOCK SELECTED FOR EQUIPMENT ST2 01150F01 CLK SEC CLOCK SELECTED FOR EQUIPMENT ST2 01150F02 CLK EXT2 INPUT SIGNAL SELECTED FOR EQUIPMENT ST2 01150F03 CLK EXT1 INPUT SIGNAL SELECTED FOR EQUIPMENT ST2 01150F04 CLK DMR2 CLOCK SELECTED FOR EQUIPMENT ST2 01150F05 CLK DMR1 CLOCK SELECTED FOR EQUIPMENT ST2 01150F06 CLK MUX2 CLOCK SELECTED FOR EQUIPMENT ST2 01150F07 CLK MUX1 CLOCK SELECTED FOR EQUIPMENT ST2 01151004 CLK DMR2 CLOCK SELECTED FOR LINE(EXT OUT) ST2 01151005 CLK DMR1 CLOCK SELECTED FOR LINE(EXT OUT) ST2 01151006 CLK MUX2 CLOCK SELECTED FOR LINE(EXT OUT) ST2 01151007 CLK MUX1 CLOCK SELECTED FOR LINE(EXT OUT) ST2 01151102 CLK EXT2 INPUT WAIT TO RESTORE ST1 01151103 CLK EXT1 INPUT WAIT TO RESTORE ST1 01151104 CLK DMR2 CLOCK WAIT TO RESTORE ST1 01151105 CLK DMR1 CLOCK WAIT TO RESTORE ST1 01151106 CLK MUX2 CLOCK WAIT TO RESTORE ST1 01151107 CLK MUX1 CLOCK WAIT TO RESTORE ST1 01151500 CLK MUX1(EQUIPMENT) QL MON = QL-INV ST2 01151501 CLK MUX1(EQUIPMENT) QL MON = QL-PRC ST2 01151502 CLK MUX1(EQUIPMENT) QL MON = QL-SSUT ST2 01151503 CLK MUX1(EQUIPMENT) QL MON = QL-SSUL ST2 01151504 CLK MUX1(EQUIPMENT) QL MON = QL-SEC ST2 01151505 CLK MUX1(EQUIPMENT) QL MON = QL-DNU ST2 01151506 CLK MUX1(EQUIPMENT) QL MON = QL-FAILED ST2

Page 53: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 53

HEX Module Alarm Text Level 01151507 CLK MUX1(EQUIPMENT) QL MON = QL-FAILED ST2 01151508 CLK MUX1(EQUIPMENT) QL MON = QL-NSUPP ST2 01151509 CLK MUX1(EQUIPMENT) QL MON = QL-INV ST2 0115150A CLK MUX1(EQUIPMENT) QL MON = QL-PRS ST2 0115150B CLK MUX1(EQUIPMENT) QL MON = QL-ST2 ST2 0115150C CLK MUX1(EQUIPMENT) QL MON = QL-ST3 ST2 0115150D CLK MUX1(EQUIPMENT) QL MON = QL-SIC ST2 0115150E CLK MUX1(EQUIPMENT) QL MON = QL-DUS ST2 0115150F CLK MUX1(EQUIPMENT) QL MON = QL-FAILED ST2 01151510 CLK MUX1(EQUIPMENT) QL MON = QL-STU ST2 01151511 CLK MUX1(EQUIPMENT) QL MON = QL-NSUPP ST2 01151512 CLK MUX2(EQUIPMENT) QL MON = QL-INV ST2 01151513 CLK MUX2(EQUIPMENT) QL MON = QL-PRC ST2 01151514 CLK MUX2(EQUIPMENT) QL MON = QL-SSUT ST2 01151515 CLK MUX2(EQUIPMENT) QL MON = QL-SSUL ST2 01151516 CLK MUX2(EQUIPMENT) QL MON = QL-SEC ST2 01151517 CLK MUX2(EQUIPMENT) QL MON = QL-DNU ST2 01151518 CLK MUX2(EQUIPMENT) QL MON = QL-FAILED ST2 01151519 CLK MUX2(EQUIPMENT) QL MON = QL-FAILED ST2 0115151A CLK MUX2(EQUIPMENT) QL MON = QL-NSUPP ST2 0115151B CLK MUX2(EQUIPMENT) QL MON = QL-INV ST2 0115151C CLK MUX2(EQUIPMENT) QL MON = QL-PRS ST2 0115151D CLK MUX2(EQUIPMENT) QL MON = QL-ST2 ST2 0115151E CLK MUX2(EQUIPMENT) QL MON = QL-ST3 ST2 0115151F CLK MUX2(EQUIPMENT) QL MON = QL-SIC ST2 01151520 CLK MUX2(EQUIPMENT) QL MON = QL-DUS ST2 01151521 CLK MUX2(EQUIPMENT) QL MON = QL-FAILED ST2 01151522 CLK MUX2(EQUIPMENT) QL MON = QL-STU ST2 01151523 CLK MUX2(EQUIPMENT) QL MON = QL-NSUPP ST2 01151600 CLK DMR1(EQUIPMENT) QL MON = QL-INV ST2 01151601 CLK DMR1(EQUIPMENT) QL MON = QL-PRC ST2 01151602 CLK DMR1(EQUIPMENT) QL MON = QL-SSUT ST2 01151603 CLK DMR1(EQUIPMENT) QL MON = QL-SSUL ST2 01151604 CLK DMR1(EQUIPMENT) QL MON = QL-SEC ST2 01151605 CLK DMR1(EQUIPMENT) QL MON = QL-DNU ST2 01151606 CLK DMR1(EQUIPMENT) QL MON = QL-FAILED ST2 01151607 CLK DMR1(EQUIPMENT) QL MON = QL-FAILED ST2 01151608 CLK DMR1(EQUIPMENT) QL MON = QL-NSUPP ST2 01151609 CLK DMR1(EQUIPMENT) QL MON = QL-INV ST2 0115160A CLK DMR1(EQUIPMENT) QL MON = QL-PRS ST2 0115160B CLK DMR1(EQUIPMENT) QL MON = QL-ST2 ST2 0115160C CLK DMR1(EQUIPMENT) QL MON = QL-ST3 ST2 0115160D CLK DMR1(EQUIPMENT) QL MON = QL-SIC ST2 0115160E CLK DMR1(EQUIPMENT) QL MON = QL-DUS ST2 0115160F CLK DMR1(EQUIPMENT) QL MON = QL-FAILED ST2 01151610 CLK DMR1(EQUIPMENT) QL MON = QL-STU ST2 01151611 CLK DMR1(EQUIPMENT) QL MON = QL-NSUPP ST2

Page 54: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 54

HEX Module Alarm Text Level 01151612 CLK DMR2(EQUIPMENT) QL MON = QL-INV ST2 01151613 CLK DMR2(EQUIPMENT) QL MON = QL-PRC ST2 01151614 CLK DMR2(EQUIPMENT) QL MON = QL-SSUT ST2 01151615 CLK DMR2(EQUIPMENT) QL MON = QL-SSUL ST2 01151616 CLK DMR2(EQUIPMENT) QL MON = QL-SEC ST2 01151617 CLK DMR2(EQUIPMENT) QL MON = QL-DNU ST2 01151618 CLK DMR2(EQUIPMENT) QL MON = QL-FAILED ST2 01151619 CLK DMR2(EQUIPMENT) QL MON = QL-FAILED ST2 0115161A CLK DMR2(EQUIPMENT) QL MON = QL-NSUPP ST2 0115161B CLK DMR2(EQUIPMENT) QL MON = QL-INV ST2 0115161C CLK DMR2(EQUIPMENT) QL MON = QL-PRS ST2 0115161D CLK DMR2(EQUIPMENT) QL MON = QL-ST2 ST2 0115161E CLK DMR2(EQUIPMENT) QL MON = QL-ST3 ST2 0115161F CLK DMR2(EQUIPMENT) QL MON = QL-SIC ST2 01151620 CLK DMR2(EQUIPMENT) QL MON = QL-DUS ST2 01151621 CLK DMR2(EQUIPMENT) QL MON = QL-FAILED ST2 01151622 CLK DMR2(EQUIPMENT) QL MON = QL-STU ST2 01151623 CLK DMR2(EQUIPMENT) QL MON = QL-NSUPP ST2 01151700 CLK EXT1 QL MON = QL-INV ST2 01151701 CLK EXT1 QL MON = QL-PRC ST2 01151702 CLK EXT1 QL MON = QL-SSUT ST2 01151703 CLK EXT1 QL MON = QL-SSUL ST2 01151704 CLK EXT1 QL MON = QL-SEC ST2 01151705 CLK EXT1 QL MON = QL-DNU ST2 01151706 CLK EXT1 QL MON = QL-FAILED ST2 01151707 CLK EXT1 QL MON = QL-FAILED ST2 01151708 CLK EXT1 QL MON = QL-NSUPP ST2 01151709 CLK EXT1 QL MON = QL-INV ST2 0115170A CLK EXT1 QL MON = QL-PRS ST2 0115170B CLK EXT1 QL MON = QL-ST2 ST2 0115170C CLK EXT1 QL MON = QL-ST3 ST2 0115170D CLK EXT1 QL MON = QL-SIC ST2 0115170E CLK EXT1 QL MON = QL-DUS ST2 0115170F CLK EXT1 QL MON = QL-FAILED ST2 01151710 CLK EXT1 QL MON = QL-STU ST2 01151711 CLK EXT1 QL MON = QL-NSUPP ST2 01151712 CLK EXT2 QL MON = QL-INV ST2 01151713 CLK EXT2 QL MON = QL-PRC ST2 01151714 CLK EXT2 QL MON = QL-SSUT ST2 01151715 CLK EXT2 QL MON = QL-SSUL ST2 01151716 CLK EXT2 QL MON = QL-SEC ST2 01151717 CLK EXT2 QL MON = QL-DNU ST2 01151718 CLK EXT2 QL MON = QL-FAILED ST2 01151719 CLK EXT2 QL MON = QL-FAILED ST2 0115171A CLK EXT2 QL MON = QL-NSUPP ST2 0115171B CLK EXT2 QL MON = QL-INV ST2 0115171C CLK EXT2 QL MON = QL-PRS ST2

Page 55: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 55

HEX Module Alarm Text Level 0115171D CLK EXT2 QL MON = QL-ST2 ST2 0115171E CLK EXT2 QL MON = QL-ST3 ST2 0115171F CLK EXT2 QL MON = QL-SIC ST2 01151720 CLK EXT2 QL MON = QL-DUS ST2 01151721 CLK EXT2 QL MON = QL-FAILED ST2 01151722 CLK EXT2 QL MON = QL-STU ST2 01151723 CLK EXT2 QL MON = QL-NSUPP ST2 01160000 OH INTFC PANEL SERVICE STATE ST1 01160003 OH INTFC MODULE TYPE MISMATCH MJ 01160007 OH INTFC OH INTFC UNEQUIPPED ALM MJ 01160200 OH INTFC OH INTFC ALM MJ 01160201 OH INTFC STBY CH ALM MJ 01160204 OH INTFC RSOH PROT CH SELECTED ST2 01160205 OH INTFC DSC PROT CH SELECTED ST2 01160401 OH INTFC DSC MAIN FRAME SYNC ALM MJ 01160402 OH INTFC DSC REG CH BER ALM MJ 01160403 OH INTFC DSC PROT CH BER ALM MJ 01160404 OH INTFC DSC REG CH FRAME SYNC ALM MJ 01160405 OH INTFC DSC PROT CH FRAME SYNC ALM MJ 01160406 OH INTFC DSC INS ALM MJ 01160407 OH INTFC DSC DROP ALM MJ 01160500 OH INTFC MSOH INS ALM [TO MUX] MJ 01160501 OH INTFC MSOH DROP ALM [FROM DMR] MJ 01160502 OH INTFC MSOH INS ALM [TO DMR] MJ 01160503 OH INTFC MSOH DROP ALM [FROM MUX] MJ 01160504 OH INTFC RSOH INS ALM [TO MUX] MJ 01160505 OH INTFC RSOH DROP ALM [FROM DMR] MJ 01160506 OH INTFC RSOH INS ALM [TO DMR] MJ 01160517 OH INTFC RSOH DROP ALM [FROM MUX] MJ 01160537 OH INTFC RSOH DROP ALM [FROM DMR] MJ 01170000 OH EXT PANEL SERVICE STATE ST1 01170003 OH EXT MODULE TYPE MISMATCH MJ 01170007 OH EXT OH EXT UNEQUIPPED ALM MJ 01170201 OH EXT OH EXT ALM MJ 01170202 OH EXT MASTER B CLK INPUT LOSS MJ 01170203 OH EXT MASTER A CLK INPUT LOSS MJ 01170300 OH EXT 64K BIP 1 AIS RCVD(TO MUX) ST1 01170301 OH EXT 64K BIP 1 INPUT LOSS(TO MUX) MJ 01170302 OH EXT 64K BIP 1 OUTPUT LOSS(FROM DMR) MJ 011703A3 OH EXT 64K BIP 1 AIS RCVD(TO DMR) ST1 011703A4 OH EXT 64K BIP 1 INPUT LOSS(TO DMR) MJ 011703A5 OH EXT 64K BIP 1 OUTPUT LOSS(FROM MUX) MJ 011703B3 OH EXT 64K BIP 1 AIS RCVD ST1 011703B4 OH EXT 64K BIP 1 INPUT LOSS MJ 011703B5 OH EXT 64K BIP 1 OUTPUT LOSS MJ 01170400 OH EXT 64K BIP 2 AIS RCVD(TO MUX) ST1 01170401 OH EXT 64K BIP 2 INPUT LOSS(TO MUX) MJ

Page 56: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 56

HEX Module Alarm Text Level 01170402 OH EXT 64K BIP 2 OUTPUT LOSS(FROM DMR) MJ 011704A3 OH EXT 64K BIP 2 AIS RCVD(TO DMR) ST1 011704A4 OH EXT 64K BIP 2 INPUT LOSS(TO DMR) MJ 011704A5 OH EXT 64K BIP 2 OUTPUT LOSS(FROM MUX) MJ 011704B3 OH EXT 64K BIP 2 AIS RCVD ST1 011704B4 OH EXT 64K BIP 2 INPUT LOSS MJ 011704B5 OH EXT 64K BIP 2 OUTPUT LOSS MJ 01170500 OH EXT 64K BIP 3 AIS RCVD(TO MUX) ST1 01170501 OH EXT 64K BIP 3 INPUT LOSS(TO MUX) MJ 01170502 OH EXT 64K BIP 3 OUTPUT LOSS(FROM DMR) MJ 011705A3 OH EXT 64K BIP 3 AIS RCVD(TO DMR) ST1 011705A4 OH EXT 64K BIP 3 INPUT LOSS(TO DMR) MJ 011705A5 OH EXT 64K BIP 3 OUTPUT LOSS(FROM MUX) MJ 011705B3 OH EXT 64K BIP 3 AIS RCVD ST1 011705B4 OH EXT 64K BIP 3 INPUT LOSS MJ 011705B5 OH EXT 64K BIP 3 OUTPUT LOSS MJ 01180000 HS/SWO CTRL PANEL SERVICE STATE ST1 01180003 HS/SWO CTRL MODULE TYPE MISMATCH MJ 01180007 HS/SWO CTRL HS/SWO CTRL UNEQUIPPED ALM MJ 01180200 HS/SWO CTRL HS SW OPERATION ST2 01180205 HS/SWO CTRL FRAME SYNC LOSS AT FAR-END ST1 01180206 HS/SWO CTRL HS SW SERVICE FAILURE CR 01180300 HS/SWO CTRL HL SW OPERATION ST2 01180306 HS/SWO CTRL HL SW SERVICE FAILURE CR 01180307 HS/SWO CTRL HS/SWO CTRL ALM MJ 01190000 150M UNIT SW PANEL SERVICE STATE ST1 01190003 150M UNIT SW MODULE TYPE MISMATCH MJ 01190007 150M UNIT SW 150M UNIT SW UNEQUIPPED ALM MJ 01190200 150M UNIT SW 150M UNIT SW ALM MJ 01200000 TRP & RP PANEL SERVICE STATE ST1 01200003 TRP & RP MODULE TYPE MISMATCH MJ 012000A7 TRP & RP TRP UNEQUIPPED ALM MJ 012000E7 TRP & RP RP UNEQUIPPED ALM MJ 01200100 TRP & RP SD RECEIVE LEVEL ALM MJ 01200101 TRP & RP MAIN RECEIVE LEVEL ALM MJ 01200102 TRP & RP RECEIVE LEVEL ALM MJ 01200103 TRP & RP RX APC/LOCAL LEVEL ALM MJ 01200104 TRP & RP TX APC ALM MJ 01200105 TRP & RP TX LEVEL ALM MJ 01200200 TRP & RP PS ALM MJ 01200201 TRP & RP OUT OF SERVICE(SW POSITION) ST1 01200202 TRP & RP EPS FUNCTION STATUS ST1 01200203 TRP & RP RX AGC FUNCTION STATUS ST1 01200205 TRP & RP ATPC ALM MJ 01200206 TRP & RP SD CONTROL ALM MJ 01300000 DC-DC CONV PANEL SERVICE STATE ST1 01300003 DC-DC CONV MODULE TYPE MISMATCH MJ

Page 57: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 57

HEX Module Alarm Text Level 01300007 DC-DC CONV DC-DC CONV UNEQUIPPED ALM MJ 01300105 DC-DC CONV PS ALM MJ 01400000 CTRL PANEL SERVICE STATE ST1 01400003 CTRL MODULE TYPE MISMATCH MJ 01400007 CTRL CTRL UNEQUIPPED ALM MJ 01400100 CTRL BUS PROTECT SW STATUS ST1 01400101 CTRL MAINTENANCE ST1 01400104 CTRL SERIAL BUS ACCESS FAILURE MJ 01400105 CTRL CTRL ALM MJ 02000100 SWO PROC F SYNC ALM(REG) MJ 02000101 SWO PROC BER ALM(REG) MJ 02000102 SWO PROC EW(REG) MJ 02000103 SWO PROC RCVY(REG) ST1 02000104 SWO PROC TIM ALM(REG) MJ 02000105 SWO PROC SVCE FAIL(REG) CR 02000106 SWO PROC PSWO(REG) ST1 02000202 SWO PROC TX SW ANS(REG) ST1 02000203 SWO PROC HL SW ANS(REG) ST1 02000301 SWO PROC FORCED SW OP STS(REG) ST1 02000302 SWO PROC LOCKOUT OP STS(REG) ST1 02000303 SWO PROC TX TEST OP(REG) ST1 02000304 SWO PROC MNL SW OP STS(REG) ST1 02000306 SWO PROC DSBL OP(REG) ST1 02000401 SWO PROC MNL EXER(REG) ST1 02000403 SWO PROC EXER WAIT(REG) ST1 02000404 SWO PROC EXER OTHERS ALM(REG) MJ 02000405 SWO PROC EXER RST TX ALM(REG) MJ 02000406 SWO PROC EXER TIM ALM(REG) MJ 02000407 SWO PROC EXER INIT TX ALM(REG) MJ 02000500 SWO PROC F SYNC ALM I(REG) MJ 02000501 SWO PROC BER ALM I(REG) MJ 02000502 SWO PROC EW I(REG) MJ 02000504 SWO PROC TIM ALM I(REG) ST1 02000602 SWO PROC TX SW ANS I(REG) ST1 02000603 SWO PROC HL SW ANS I(REG) ST1 02000704 SWO PROC TCN-15MIN REG SWO FAIL DUR MN 02000705 SWO PROC TCN-15MIN REG SWO DUR MN 02000706 SWO PROC TCN-15MIN REG SWO FAIL CNT MN 02000707 SWO PROC TCN-15MIN REG SWO CNT MN 02000802 SWO PROC TCN-15MIN REG F SYNC ALM DUR MN 02000803 SWO PROC TCN-15MIN REG BER ALM DUR MN 02000804 SWO PROC TCN-15MIN REG EW DUR MN 02000805 SWO PROC TCN-15MIN REG F SYNC ALM CNT MN 02000806 SWO PROC TCN-15MIN REG BER ALM CNT MN 02000807 SWO PROC TCN-15MIN REG EW CNT MN 02000904 SWO PROC TCN-1DAY REG SWO FAIL DUR MN 02000905 SWO PROC TCN-1DAY REG SWO DUR MN

Page 58: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 58

HEX Module Alarm Text Level 02000906 SWO PROC TCN-1DAY REG SWO FAIL CNT MN 02000907 SWO PROC TCN-1DAY REG SWO CNT MN 02001002 SWO PROC TCN-1DAY REG F SYNC ALM DUR MN 02001003 SWO PROC TCN-1DAY REG BER ALM DUR MN 02001004 SWO PROC TCN-1DAY REG EW DUR MN 02001005 SWO PROC TCN-1DAY REG F SYNC ALM CNT MN 02001006 SWO PROC TCN-1DAY REG BER ALM CNT MN 02001007 SWO PROC TCN-1DAY REG EW CNT MN 02010100 SWO PROC F SYNC ALM(PROT) MJ 02010101 SWO PROC BER ALM(PROT) MJ 02010102 SWO PROC EW(PROT) MJ 02010103 SWO PROC RCVY(PROT) ST1 02010104 SWO PROC TX SW CMPL(PROT) ST1 02010105 SWO PROC SVCE FAIL(PROT) CR 02010106 SWO PROC PPF(PROT) MJ 02010202 SWO PROC TX ACS SW ANS(PROT) ST1 02010203 SWO PROC RX ACS SW ANS(PROT) ST1 02010300 SWO PROC MNL ACS SW OP STS(PROT) ST1 02010301 SWO PROC FORCED ACS SW OP STS(PROT) ST1 02010302 SWO PROC LOCKOUT OP STS(PROT) ST1 02010500 SWO PROC F SYNC ALM I(PROT) MJ 02010501 SWO PROC BER ALM I(PROT) MJ 02010502 SWO PROC EW I(PROT) MJ 02010504 SWO PROC TX CMPL I(PROT) ST1 02010704 SWO PROC TCN-15MIN PROT SWO FAIL DUR MN 02010705 SWO PROC TCN-15MIN PROT SWO DUR MN 02010706 SWO PROC TCN-15MIN PROT SWO FAIL CNT MN 02010707 SWO PROC TCN-15MIN PROT SWO CNT MN 02010802 SWO PROC TCN-15MIN PROT F SYNC ALM DUR MN 02010803 SWO PROC TCN-15MIN PROT BER ALM DUR MN 02010804 SWO PROC TCN-15MIN PROT EW DUR MN 02010805 SWO PROC TCN-15MIN PROT F SYNC ALM CNT MN 02010806 SWO PROC TCN-15MIN PROT BER ALM CNT MN 02010807 SWO PROC TCN-15MIN PROT EW CNT MN 02010904 SWO PROC TCN-1DAY PROT SWO FAIL DUR MN 02010905 SWO PROC TCN-1DAY PROT SWO DUR MN 02010906 SWO PROC TCN-1DAY PROT SWO FAIL CNT MN 02010907 SWO PROC TCN-1DAY PROT SWO CNT MN 02011002 SWO PROC TCN-1DAY PROT F SYNC ALM DUR MN 02011003 SWO PROC TCN-1DAY PROT BER ALM DUR MN 02011004 SWO PROC TCN-1DAY PROT EW DUR MN 02011005 SWO PROC TCN-1DAY PROT F SYNC ALM CNT MN 02011006 SWO PROC TCN-1DAY PROT BER ALM CNT MN 02011007 SWO PROC TCN-1DAY PROT EW CNT MN 02410000 SWO PROC SWO PROC PANEL SERVICE STATE ST1 02410003 SWO PROC SWO PROC MODULE TYPE MISMATCH MJ 02410100 SWO PROC SWO EXP1 PANEL SERVICE STATE ST1

Page 59: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 59

HEX Module Alarm Text Level 02410103 SWO PROC SWO EXP1 MODULE TYPE MISMATCH MJ 02410200 SWO PROC SWO EXP2 PANEL SERVICE STATE ST1 02410203 SWO PROC SWO EXP2 MODULE TYPE MISMATCH MJ 02410300 SWO PROC TR DIST1 I/F ALM(COM) MJ 02410400 SWO PROC TR DIST2 I/F ALM(COM) MJ 02410405 SWO PROC SWO EXP1 CLK INPUT LOSS(COM) MJ 02410406 SWO PROC SWO EXP1 LINK NG(COM) ST2 02410407 SWO PROC SWO EXP1 FAIL MJ 02410500 SWO PROC TR DIST3 I/F ALM(COM) MJ 02410505 SWO PROC SWO EXP2 CLK INPUT LOSS(COM) MJ 02410506 SWO PROC SWO EXP2 LINK NG(COM) ST2 02410507 SWO PROC SWO EXP2 FAIL MJ 02410602 SWO PROC SC FAIL(COM) MJ 02410603 SWO PROC SWO FAIL(COM) MJ 02410704 SWO PROC DSC 1 SELECTED(COM) ST2 02410705 SWO PROC DSC 0 SELECTED(COM) ST2 02410706 SWO PROC DSC 1 ALM(COM) MJ 02410707 SWO PROC DSC 0 ALM(COM) MJ 02410803 SWO PROC SWO PRIORITY MNL(COM) ST1 02410807 SWO PROC DSC A/M OP(COM) ST1 02410901 SWO PROC AUTO EXER STOP(COM) ST1 02410902 SWO PROC CNT STOP(COM) ST1 02410A04 SWO PROC TCN-15MIN COM SWO FAIL DUR MN 02410A05 SWO PROC TCN-15MIN COM SWO DUR MN 02410A06 SWO PROC TCN-15MIN COM SWO FAIL CNT MN 02410A07 SWO PROC TCN-15MIN COM SWO CNT MN 02410C04 SWO PROC TCN-1DAY COM SWO FAIL DUR MN 02410C05 SWO PROC TCN-1DAY COM SWO DUR MN 02410C06 SWO PROC TCN-1DAY COM SWO FAIL CNT MN 02410C07 SWO PROC TCN-1DAY COM SWO CNT MN 04000001 LMS ACCESS FAILURE MJ 04000101 CONTACTS POINT_1 MJ 04000102 CONTACTS POINT_2 MJ 04000103 CONTACTS POINT_3 MJ 04000104 CONTACTS POINT_4 MJ 04000105 CONTACTS POINT_5 MJ 04000106 CONTACTS POINT_6 MJ 04000107 CONTACTS POINT_7 MJ 04000108 CONTACTS POINT_8 MJ 04000109 CONTACTS POINT_9 MJ 0400010A CONTACTS POINT_10 MJ 0400010B CONTACTS POINT_11 MJ 0400010C CONTACTS POINT_12 MJ 0400010D CONTACTS POINT_13 MJ 0400010E CONTACTS POINT_14 MJ 0400010F CONTACTS POINT_15 MJ 04000110 CONTACTS POINT_16 MJ

Page 60: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 60

HEX Module Alarm Text Level 04000111 CONTACTS POINT_17 MJ 04000112 CONTACTS POINT_18 MJ 04000113 CONTACTS POINT_19 MJ 04000114 CONTACTS POINT_20 MJ 04000115 CONTACTS POINT_21 MJ 04000116 CONTACTS POINT_22 MJ 04000117 CONTACTS POINT_23 MJ 04000118 CONTACTS POINT_24 MJ 04000119 CONTACTS POINT_25 MJ 0400011A CONTACTS POINT_26 MJ 0400011B CONTACTS POINT_27 MJ 0400011C CONTACTS POINT_28 MJ 0400011D CONTACTS POINT_29 MJ 0400011E CONTACTS POINT_30 MJ 0400011F CONTACTS POINT_31 MJ 04000120 CONTACTS POINT_32 MJ 04000121 CONTACTS DO_POINT_1 MJ 04000122 CONTACTS DO_POINT_2 MJ 04000123 CONTACTS DO_POINT_3 MJ 04000124 CONTACTS DO_POINT_4 MJ 04000125 CONTACTS DO_POINT_5 MJ 04000126 CONTACTS DO_POINT_6 MJ 04000127 CONTACTS DO_POINT_7 MJ 04000128 CONTACTS DO_POINT_8 MJ

Page 61: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Appendix E – SCS100 Installation and Configuration The Lantronix SCS100 terminal server is preconfigured to an IP of 10.16.15.100. To configure the unit for your network, either login to 10.16.15.100 using a web browser or telnet client. The local consol port is disabled by default. Browser user access user/password = login/access Browser configuration access user/password = root/system Telnet user access user/password = login/access Telnet configuration access user/password = su/system You must login as a user before entering configuration mode. To enter configuration(Super User) mode from telnet,login as user, then type su, then enter the password when prompted. Escape character is '^]'. sho port 1 - get the current port settings Example setup: def ip ipaddress 10.16.15.100 def ip subnet 255.255.0.0 def ip route default next 10.16.15.1 def server bootp disable def server rarp disable def port 1 speed 9600 def port 1 access remote def port 1 broad disable def port 1 flow none def port 1 ver disable def port 1 loss disable def port 1 ppp disable def port 1 broadcast disable def port 1 loss notification disable def port 1 pppdetect disable def port 1 backward "^B" def port 1 local "^\" def protocols http enable def server silent enable def protocols http enabled def snmp community al@RM$PRO access both

Revision 3.1.0 Page 61

Page 62: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 62

sample.properties # Your company name. company=My Company # Your serial number. sn=XXXX-XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX-XXXXXXXXXXXXXX-XX # The host name or IP address of the Primary Terminal Server. ip=127.0.0.1 # The Telnet or SSH port of the Primary Terminal Server. # On NLITE systems, the SNMP port of the connected PNMS-LAN interface. port=23 # The Primary SSH login name. If defined a SSH connection will be attempted. ssh-login=mysshlogin # The Primary SSH password, if any. ssh-password=mysshpwd # The host name or IP address of the Secondary (Redundant) Terminal Server. secondary-ip=127.0.0.1 # The Telnet or SSH port of the Secondary (Redundant) Terminal Server. secondary-port=23 # The Secondary (Redundant) SSH login name. If defined a SSH connection will be attempted. secondary-ssh-login=mysshlogin # The Secondary (Redundant) SSH password, if any. secondary-ssh-password=mysshpwd # The host name or IP address of the NMS Server. The port can be specified using a colon. # Multiple IPs can be specified when separated by a comma. # Set the "0.0.0.0" to disable all NMS traps. nms-ip=127.0.0.1[:162] # The default NMS Server port which receives SNMP Traps. nms-port=162 # The NMS/SNMP community, if any. nms-community=public # The NMS Microwave ID, if any. nms-id=254 # Set to "true" to perform Multi-IP radio lookup, "false" otherwise. ip-lookup=false # Set to "true" to perform automated time synchronization, "false" otherwise. timesync=true # Set the automated time synchronization frequency in hours. # The default/minimum is 24 hours, maximum is 731 hours (a month). timesync-frequency=24 # Set to "true" to report unknown alarms, "false" otherwise. unknown=true # Set to "true" to force status queries on all radios, "false" otherwise. forced-status=false # Set to "false" to disable correlation, "true" otherwise. correlation=true # Set to "true" to enable telemetering or download of performance data (NLITE), "false" otherwise. telemetering=false # The Mail Server (SMTP) host name or IP address. smtp=127.0.0.1 # The email address to send notifications to, if any. # Multiple recipients can be specified when separated by a comma. [email protected] # A Microwave Radio, defined as follows: # # For System2000 and System3000: # # radioX=<RADIO NAME>,<NSAP ADDRESS>,<TSAP ADDRESS>[,IP ADDRESS][,TX POWER THREHSOLD][,RSL THRESHOLD],[PM TRUE OR FALSE]

Page 63: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 63

# # For NLITE: # # radioX=<RADIO NAME>,<COMMUNITY STRING: READ>,<COMMUNITY STRING: WRITE>,<IP ADDRESS> # # where X is between 1 and 64. # radio1=FIRSTRADIO,1234567890123456789012345678901234567890,169.0.0.1,+17,-60,FALSE radio2=SECONDRADIO,1234567890123456789012345678901234567890,,+17,-60 # NLITE # # The following properties are only for NLITE systems. # # The read/write community string for the PNMS-LAN interface. lan-community=public

Page 64: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 64

Sample.db.properties # The database log location. derby.stream.error.file=logs/db.log # Enable authentication. derby.connection.requireAuthentication=true # Un-comment to change the port, default is 1527. #derby.drda.portNumber=1527 # Un-comment to allow remote connections. #derby.drda.host=0.0.0.0 # Set the 'report' username and password. derby.user.report=report123 # Enable read-only access for the 'report' user. derby.database.readOnlyAccessUsers=report # Maximum number of days to keep database records for. # Valid values are: 15, 30, 45, 60, 75 or 90. # The default is 90 days. # #alarmspro.database.cleanup=90

Page 65: Manager - AlarmsPro · Cover Manager for System2000, System3000, PM add-on, Pasolink and nLite User’s Guide Revision 3.1.0 Page 1

Revision 3.1.0 Page 65

log4j.properties log4j.rootLogger=FATAL, R # Log File Location log4j.appender.R.File=../logs/alarmspro.log # Rolling Log File (By Size) log4j.appender.R=org.apache.log4j.RollingFileAppender log4j.appender.R.MaxBackupIndex=10 log4j.appender.R.MaxFileSize=10MB # Rolling Log File (Daily) #log4j.appender.R=org.apache.log4j.DailyRollingFileAppender #log4j.appender.R.DatePattern='.'yyyy-MM-dd # Log File Layout log4j.appender.R.layout=org.apache.log4j.PatternLayout log4j.appender.R.layout.ConversionPattern=[%d{yyyy-MM-dd HH:mm:ss}] [%p] %m%n # Print only messages of priority FATAL or above in the package com.sshtools log4j.com.sshtools=FATAL # Print only messages of priority INFO or above in the package com.alarmspro log4j.category.com.alarmspro=INFO