Maintenance

29
This manual is the property of Ceragon Networks. No parts of the manual may be copied, rewritten or distributed to third parties without the written permission from Ceragon Networks. For best readability, a screen resolution of at least 1280 by 1024 pixels is recommended. Display font setting: Normal size. The manual is divided in 5 main parts: User Manual - Maintenance DOC-00036540 BM-0269-0 Rev a.02 General Installation Operation Maintenance Appendices Provides a general overview of the equipment Provides the details on how to install the equipment. Describes how to operate the system using either the Web EMS or the CLI. Provides details on maintenance of the equipment A collection of frequency plans, alarm lists, technical specifications etc.

Transcript of Maintenance

This manual is the property of Ceragon Networks. No parts of the manual may be copied, rewritten or distributed to third parties without the writtenpermission from Ceragon Networks.

For best readability, a screen resolution of at least 1280 by 1024 pixels is recommended. Display font setting: Normal size.

The manual is divided in 5 main parts:

User Manual - Maintenance

DOC-00036540BM-0269-0Rev a.02

General

Installation

Operation

Maintenance

Appendices

Provides a general overview of the equipment

Provides the details on how to install the equipment.

Describes how to operate the system using either the Web EMS or the CLI.

Provides details on maintenance of the equipment

A collection of frequency plans, alarm lists, technical specifications etc.

Fault FindingThe equipment designed to be highly reliable and relatively maintenance free. In the event of a system failure, the system willprovide detailed indications to assist troubleshooting and fault isolation. This chapter explains the alarm indications, and containsprocedures for troubleshooting and fault isolation.

To ensure simple and efficient system maintenance, the on-site technician will only replace IDU or RFU modules, and not repairthem. Under no circumstance will the technician be permitted to open the equipment in order to repair a module or circuit board.Opening equipment will terminate the warranty.

Maintenance procedures the technician can perform include visual inspection, cleaning, cable/connector repair, linkalignment/adjustment, and re-torquing antenna mount bolts.

The following table lists the suggested preventive maintenance procedures, which include visual inspection of the equipment andverification of operational parameters.It is recommended to perform the procedures as often as local environmental conditions require. It is recommended to notify theend customer prior to performing any preventive maintenance procedures that could affect service on the circuit.

Corrective maintenance consists of the steps described below. The steps provide a logical, sequential method for diagnosing andresolving system problems.

Step 1: Define the SymptomThis step is generally performed by the customer's field technician or supervisor. Examples of symptoms include “IDU alarm isred”, “complete loss of service”, and “excessive errors”.Symptoms may be constant or intermittent. Constant symptoms require immediate troubleshooting attention. Intermittentsymptoms may require circuit monitoring or robust test procedures prior to troubleshooting.

Step 2: Isolate the ProblemAfter you have a clear definition of the symptom, the malfunction can be isolated using diagnostics, loopback testing, fault isolationtables/flow charts, test equipment, and manual procedures.This step will identify the specific piece of equipment that is failing.Although it may be difficult at times to immediately determine which part of a radio link is causing the fault, the initial suspicionshould be focused on one of the following near-end or far-end issues:

Power supplies

Fading (due to heavy rain, new obstacle in path, antenna misalignment)

External equipment (SDH/SONET, ATM, Fast Ethernet, etc.)

Indoor Unit (IDU)

Radio Frequency Unit (RFU)

RF cable between the RFU and IDU

Exposure of equipment to severe conditions (high temperature, etc.)

System configuration

Step 3: Understand the ProblemOnce the fault has been isolated, you will need to understand why the fault occurred and what is required to correct it. Use thetables provided in the following sections to understand the problem, and for suggestions of possible solutions.

Step 4: Solve the ProblemUse the troubleshooting information in this chapter to help solve the problem.

What to check Check for… Comments

IDU alarm LEDs All green If not, perform troubleshooting

Coax cable connection Tight, no corrosion or moisture Clean/repair as required

Coax cable No cracks or kinks Replace as required

All equipment Dust or dirt Clean as required

Receive level (voltage in IDU/ODU/RFU, or usingmanagement)

Per installation records Align/adjust as required

Torque on antenna mount bolts Tight mount Adjust as required

Installing and Replacing Cards in the ChassisThe new card must have exactly the same unit code (Code:) as the unit to be replaced.

Note! This equipment contains components which are sensitive to "ESD" (Electro Static Discharge). It is thereforeessential that whenever disassembling the equipment and/or handling PC boards, special precautions to avoid ESD aremade. These precautions include personnel grounding, grounding of work bench, grounding of tools and instruments aswell as transport and storage in special antistatic bags and boxes.

Replacing the Chassis

Note! When a complete IDU is replaced, the traffic through this IDU will be interrupted.

1. Unplug the power connector(s) on the PDC card(s).2. Disconnect all cables from the cards in the chassis. Mark all cables to ensure that the cables can be reconnected to

the correct cards and interfaces in the new chassis.3. Disconnect the chassis grounding cable.4. Since the chassis fully populated is heavy, It may be convenient to remove cards prior to removing chassis from the

rack.5. Unscrew the chassis from the rack (four screws).6. Carefully pull the chassis out.7. Remove all cards from the chassis.

Replacement1. Replace the cards in the new chassis.2. Carefully insert the new chassis into the rack.3. Fasten the four screws.4. Reconnect the chassis grounding cable.5. Re-insert all cards.Tighten the capive screws gently with a screwdriver.6. Reconnect the front cables.7. Reconnect the power cable(s).

RMC/LIC Installation and Replacement

1. Disconnect all cables on the card to be replaced.2. Unscrew the two captive screws that secure the card to the chassis. A screwdriver may be used if necessary to

unscrew the screws.3. Release the card from the backplane connectors by means of the card ejectors. See animation above.4. Carefully remove the card from the chassis by pulling the screws.

Replacement1. Carefully insert the new card. Ensure that the card enters the guides inside the chassis and gently press the card to

enter the internal connectors without the use of excessive force. Make sure that the card ejectors lock in the correctposition. See animation above.

2. Fasten the two captive screws gently with a screwdriver.3. Reconnect all cables.

RemoveRMC

Insert RMC

TCC Installation and Replacement

Installation of a TCC in a New System

When installing a new system, the new TCC is delivered with an SD card, which stores the unit's software version andconfiguration. The SD card is packaged in a compartment in the front portion of the TCC package. It is placed in such away that you can view the label and serial number of the SD card before opening the package.

1. Carefully remove the SD card from the package.

2. Before installing the TCC, insert the SD card into its socket on the upper left side of the TCC. Make sure theorientation of the SD card is correct, as shown in the figure below.

When the SD card is inserted properly, it should click into place. The figure below shows an SD card properly inserted inits socket on the TCC.

3. Carefully insert the new TCC. Ensure that the TCC enters the guides inside the chassis and gently press the TCC toenter the internal connectors without the use of excessive force. Make sure that the card ejectors lock in the correctposition. See animation below.

4. Fasten the two captive screws gently with a screwdriver.

Replacement

In addition to the procedure below, it is important that the correct system configuration is reloaded from a backup file whenthe TCC is replaced by a new TCC.

1. Remove the SD card. Afterwards, you will insert the SD card into the new TCC in order to preserve the system'scurrent software and configuration. To remove the SD card, press down gently on the card and slide the card out ofits socket on the upper left side of the TCC.

2. Disconnect all cables on the TCC to be replaced.3. Unscrew the two captive screws that secure the TCC to the chassis. A screwdriver may be used if necessary to

unscrew the screws.4. Release the TCC from the backplane connectors by means of the card ejectors. See animation above.5. Carefully remove the TCC from the chassis by pulling the screws.6. Carefully insert the new TCC. Ensure that the TCC enters the guides inside the chassis and gently press the TCC to

enter the internal connectors without the use of excessive force. Make sure that the card ejectors lock in the correctposition. See animation above.

7. Fasten the two captive screws gently with a screwdriver.8. Remove the SFP caps from the TCC.

RemoveTCC

Insert TCC

9. Reconnect all cables.10. Re-insert the SD card that you removed from the old TCC.

Replacing a PDC

1. Disconnect the power cable on the card to be replaced.2. Unscrew the two captive screws that secure the card to the chassis. A screwdriver may be used if necessary to

unscrew the screws.3. Carefully remove the card from the chassis by pulling the screws.

Replacement1. Carefully insert the new card. Ensure that the card enters the guides inside the chassis and gently press the card to

enter the internal connectors without the use of excessive force. See animation above.2. Fasten the two captive screws gently with a screwdriver.3. Reconnect the power cable.

RemovePDC

Insert PDC

1. Unscrew the two captive screws that secure the FANs drawer to the chassis. A screwdriver may be used ifnecessary to unscrew the screws.

2. Carefully remove the drawer from the chassis by pulling the screws.

Replacement1. Carefully insert the new FANs drawer. Ensure that the drawer enters the guides inside the chassis and gently press

the card to enter the internal connectors without the use of excessive force. See animation above.2. Fasten the two captive screws gently with a screwdriver.

Filter Unit ReplacementThe Filter Unit consists of a filter tray and a filter foam. The filter foam needs to be changed or cleaned from time to time,depending on the environmental conditions.Follow the procedure below to change or clean the filter foam.

RemoveFANs

Insert FANs

FANs Drawer Replacement

The filter tray is secured to the chassis by means of a captive screw (no ejectors)1. Unscrew the captive screw2. Remove the filter tray by pulling the captive screw3. Remove the filter foam from the filter tray

Replacement1. Replace the filter foam in the filter tray2. Slide the filter tray into the filter slot in the chassis.3. Fasten the captive screw gently with a screwdriver.

RemoveFilter

InsertFilter

Connecting the Power CableFor a 2RU Chassis

1. Plug the power connector into the PDC and tighten the two screws on the sides ofthe connector to secure the connector.

For a 1RU Chassis

1. Expose the wires of the power cable.

2. Loosen the top two screws on the connector.

3. Verify that the wiring is according to the correct polarity.

4. Insert the wires into the connector.

5. Secure the wires in the connector with the screws.

6. Plug the connector into the PDC and tighten the two screws on the sides of theconnector to secure the connector.

RFU-C Replacement

Note! Before disconnection of the RFU from the antenna/waveguide interface,make sure that the RFU power is shut off. The IDU RFU cable must be disconnected.

Direct MountLoosen the four M8 captive screws that secures the RFU to the antenna and carefullyremove the RFU from the suspension.

Before reinstallation of the new RFU, check that the O-ring gasket at the antennainterface is not damaged. If the gasket is cracked or damaged, replace it with a new one.

Re-installation

Remote Mount6-13 GHzLoosen the four M8 captive screws that secures the RFU to the pole mount bracket andcarefully remove the RFU from the bracket.

15-38 GHzRemove the flexible waveguide from the rear of the RFU by unscrewing the six screwssecuring the flexible waveguide to the RFU.

Loosen the four M8 captive screws that secures the RFU to the pole mount bracket andcarefully remove the RFU from the bracket.

Before reinstallation of the new RFU, check that the O-ring gasket at the antennainterface is not damaged. If the gasket is cracked or damaged, replace it with a new one.

Re-installation

Alarm ListsAlarm ID User Privilege Group Alarm/Event Service Affecting Severity Description Probable Cause Corrective Actions

0 Ethernet Event No Minor Path protection switch onTDM service

1) Failure along service primarypath2) User command

1) Check errors along primary path2) Check local service configuration

0 Radio Alarm No Warning Framer digital loopback User enabled framer digitalloopback Disable framer digital loopback

25 Management Alarm No Warning Unit Temperature is out ofmanufacturer limit

26 Management Alarm No Warning Unit input voltage is toolow

28 Management Event No Indeterminate

29 Management Event No Warning User initiated Reset Command

100 Ethernet Alarm No Minor LAG is not fully functional- LAG Degraded

101 Ethernet Alarm No Critical LAG operational state isdown

307 TDM Event Yes Warning TDM interface is up 10

308 TDM Event Yes Warning TDM interface is down 12

401 Ethernet Alarm Yes Major Ethernet Loss of Carrier 1) cable disconnected.2) Defective cable.

1) Check connection of cable.2) Replace cable.

407 Ethernet Event Yes Warning Ethernet interface is up 6

408 Ethernet Event Yes Warning Ethernet interface is down 8

601 Radio Alarm Yes Major Radio excessive BER

1) Fade in the link.2) Defective IF cable.3) Fault in RFU.4) Fault in IDU.

1) Check link performance.2) Check IF cable and replace ifrequired.3) Replace RFU.4) Replace IDU.

602 Radio Alarm Yes Major Link ID mismatch Link ID is not the same at bothsides of link

Configure same Link ID for bothsides of link

603 Radio Alarm No Critical Radio loss of frame

1) Fade in the link.2) Defective IF cable.3) Fault in RFU.4) Fault in IDU.5) Different radio scripts at bothends of the link.

1) Check link performance.2) Check IF cable, and replace ifrequired.3) Replace RFU.4) Replace IDU.5) Make sure same script is loadedat both ends of the link.

604 Radio Alarm Yes Minor Radio signal degrade

1) Fade in the link.2) Defective IF cable.3) Fault in RFU.4) Fault in IDU.

1) Check link performance.2) Check IF cable, and replace ifrequired.3) Replace RFU.4) Replace IDU.

605 Radio Event Yes Warning Radio interface is up 10

606 Radio Event Yes Warning Radio interface is down 12

714 Radio Alarm No Minor Fan failure Defective fan unit Replace fan unit

801 Management Alarm No Warning Corrupted inventory file The inventory file is corrupted 1) Reset the system2) Reinstall the software

802 Management Alarm No Warning Inventory file not found The inventory file is missing 1) Reset the system2) Reinstall the software

901 Management Alarm No Warning Demo license is active Demo license has been activatedby the user Disable the demo license

902 Management Event No Warning Demo license is expired

903 Management Event No Warning Demo license is started

904 Management Event No Warning Demo license is stopped

905 Management Event No Major License key loadingfailure

906 Management Event No Warning License key loadedsuccessfully

907 Management Alarm No Major License violationThe current unit configuration doesnot match the license allowedfeature set.

1. Get the list of features'configurations that are violated viathe "license information report"2. Install a new license that allowsthe usage of all the requiredfeatures.

908 Management Alarm No Major Demo license is about toexpire

Demo license allowed period isabout to end within 10 days

Disable the demo license andinstall a new valid one

910 Management Alarm No Major License signature failureLicense key validation has faileddue to invalid product serialnumber

Replace the IDU

911 Management Event No Major License violation sanctionis enforced

913 Management Alarm No Major License components aremissing or corrupted

Essential internal licensecomponents are missing orcorrupted.

Reinstall software

1002 Radio Alarm Yes Major Radio protectionconfiguration mismatch

The configuration between theradio protection members is notaligned

Apply a copy-to-mate command tocopy the configuration from therequired radio to the other one

1003 Radio Event No Indeterminate Copy to mate operation completed successfully1004 Radio Event No Warning Copy to mate operation failed1005 Radio Event No Indeterminate Copy to mate operation started

1006 Radio Event No Warning Radio protectionswitchover - reason

1007 Radio Alarm Yes Major Radio protection no mate:slot x is missing

Radio protection function ismissing radio module or module isdefected

1) Add radio module2) Replace a defective existingradio module

1008 Radio Event No Warning Remote switchoverrequest was sent - reason

1009 Radio Alarm Yes Major Radio protection lockoutcommand is on

The user has issued a lockoutcommand Clear the lockout command

1102 Management Event No Warning Software installationstatus:

1105 Management Alarm No Warning New version installedA software version has beeninstalled but system has not beenreset.

1111 Management Event No Warning User approved downloadof software version file

1112 Management Event No Warning Software downloadstatus:

1113 Management Event Warning Missing components:

1114 Management Event No Warning Incomplete file set;missing components

Software bundle is missingcomponents. Get a complete software bundle

1150 Management Event No Warning Configuration file backupgeneration started User command

1151 Management Event No Warning Configuration file backupcreated

Backup file creation finishedsuccessfully

1152 Management Event No Warning Failure in configurationfile backup generation

System failed in attempt to createbackup configuration file

1153 Management Event No Warning Configuration successfullyrestored from file backup

Configuration restore finishedsuccessfully

1154 Management Event No Warning Failure in configurationrestoring from backup file

System failed in attempt to restoreconfiguration from backup file

1. Configuration file system typemismatch2.. Invalid or corruptedconfiguration file

1155 Management Event No Warning Configuration restoreoperation cancelled

Restore operation cancelledbecause of user command orexecution of another configurationmanagement operation

Try again

1156 Management Event No WarningUser issued command fortransfer of configurationfile

User command

1157 Management Event No Warning Configuration file transfersuccessful

Configuration file transfersuccessful

1158 Management Event No Warning Configuration file transferfailure

1. Communications failure2. File not found in server

1. Make sure protocol details areproperly configured2. Make sure file exists

1159 Management Event No Warning Configuration file transferin progress File transfer started

1160 Management Event No Warning CLI script download User command1161 Management Event No Warning CLI script downloaded successfully

1162 Management Event No Warning CLI configuration scr 1. Communications failure2. File not found in server

1. Make sure protocol details areproperly configured2. Make sure file exists

1163 Management Event No Warning CLI configuration scriptactivation started User command

1164 Management Event No Warning CLI Configuration scriptexecuted successfully

1165 Management Event No Warning CLI Configuration scriptfailed

1. Syntax Error2. Error returned by system duringruntime

Verify script in the relevant line,and run again.Notice that script may assume pre-existing configuration

1166 Management Event No Warning Unit info file transferstatus:

1167 Management Event No Warning Unit info file creationstatus:

1168 Management Event No Warning CLI Configuration scr No CLI script file found in t Download CLI script file to thesystem

1169 Management Event No Warning Configuration restoreoperation started

Restore operation started becauseof user command

1201 Radio Alarm Yes Critical Modem firmware file notfound Modem file is missing 1) Download software package.

2) Reset the system

1202 Radio Alarm Yes Critical Modem firmware was notloaded successfully

1) Modem firmware file iscorrupted.2) System failure

1) Download software package.2) Reset the system

1203 Radio Event Yes Warning Modem watch-dog resetevent

1301 Radio Alarm No Critical Radio MRMC script LUTfile is corrupted

Damaged radio MRMC script LUTfile

Download the specific radio MRMCscript LUT file

1302 Radio Alarm No Critical Radio MRMC script LUTfile is not found Missing radio MRMC script LUT fileDownload the specific radio MRMC

script LUT file

1303 Radio Alarm No Critical Radio MRMC script i The required Radio MRMC

1) Check the RFU bandwidthlimitations.2) If the RFU bandwidth is narrowerthan the radio MRMC scriptbandwidth, it is possible to changeeither the radio MRMC script or theRFU.

1304 Radio Alarm No Critical Radio MRMC scriptmodem file is corrupted

Damaged radio MRMC scriptmodem file

Download the specific radio MRMCscript modem file

1305 Radio Alarm No Critical Radio MRMC scriptmodem file is not found

Missing radio MRMC script modemfile

Download the specific radio MRMCscript modem file

1308 Radio Alarm Yes Critical Radio MRMC RFU file iscorrupted

Damaged Radio MRMC script LUTfile

Download the specific radio MRMCRFU file

1309 Radio Alarm Yes Major Radio MRMC RFU file isnot found Missing radio MRMC RFU file Download the specific radio MRMC

RFU file

1312 Radio Alarm Yes Major Radio MRMC scriptloading failed Damaged hardware module Replace the radio hardware

module

1401 Radio Alarm Yes Major Incompatible RFU TXcalibration

RFU calibration tables require IDCSW upgrade Upgrade IDU SW

1501 Radio Alarm Yes Critical Remote communicationfailure Fade in the link Check the link performance

1601 Radio Alarm Yes Warning IF loopback User enabled IF loopback Disable IF loopback

1602 Radio Alarm Yes Critical IF synthesizer is unl 1) Extreme temperature condition.2) HW failure.

1) Check installation.2) Reset the IDU module.3) Replace the IDU module

1701 Radio Alarm Yes Major Cable open Cable is not connected to IDU orRFU

1) Check IF cable and connectors.2) Verify that the N-Type connectorinner pin is not spliced.3) Replace IDU.4) Replace RFU.

1702 Radio Alarm Yes Major Cable short Physical short at the IF cable

1) Check IF cable and connectors.2) Verify that N-Type/TNCconnector inner pin is not spliced.

3) Replace IDU.4) Replace RFU.

1703 Radio Alarm Yes Warning RFU communicationfailure

1) Defective IF cable.2) IF cable not connected properly.3) Defective IDU.4) Defective RFU.5) RFU software download inprogress.

1) Check IF cable and connectors.2) Verify that N-Type connectorinner pin is not spliced.3) Replace IDU.4) Replace RFU.

For High Power RF Unit:1) Check BMA connector on OCB2) Check BMA connector on RFU.

1704 Radio Alarm Yes Warning RFU delay calibrationfailure 1 Defective RFU 1) Reset the IDU/RFU.

2) Replace RFU.

1705 Radio Alarm Yes Warning RFU delay calibrationfailure 2

Calibration cannot be completeddue to notch detection

Enter delay calibration valuemanually.

1706 Radio Alarm Yes Warning RFU extreme temperature1) Installation conditions.2) Defective RFU.

1) Check installation conditions.2) Verify operation as per product'sspecs.3) Replace RFU.

1708 Radio Event Yes Warning RFU frequency was setautomatically Defective RFU

1) Check if problem repeats and iferrors/alarms reported.2) Replace ODU.

1709 Radio Alarm Yes Critical RFU hardware failure 1 Defective RFU. Replace RFU.

1710 Radio Alarm Yes Critical RFU hardware failure 2 Defective RFU. Replace RFU.

1711 Radio Alarm Yes Major Low IF signal to RFU1) IF cable connection.2) Defective RFU.3) Defective IDU.

1) Check IF cable connectors.2) Verify that N-Type connectorinner pin is not spliced.3) Replace IDU.4) Replace RFU.

1712 Radio Alarm Yes Warning Low IF signal from RFULow RX IF signal (140 MHz) from

1) Check IF cable and connectors.2) Verify that N-Type connectorinner pin is not spliced.

RFU. 3) Replace IDU.4) Replace RFU.

1713 Radio Alarm Yes Warning RFU PA extremetemperature

1) Installation conditions.2) Defective RFU.

1) Check installation conditions.2) Replace RFU.

1714 Radio Alarm Yes Major RFU power failure (1Defective IF cable/connector.2) Defective RFU.3) Defective IDU.

1) Replace IF cable/connector.2) Replace RFU.3) Replace IDU.

1715 Radio Alarm Yes Major RFU power failure (1Defective IF cable/connector.2) Defective RFU.3) Defective IDU.

1) Replace IF cable/connector.2) Replace RFU.3) Replace IDU.

1716 Radio Alarm Yes Major RFU power failure (2Defective IF cable/connector.2) Defective RFU.3) Defective IDU.

1) Replace IF cable/connector.2) Replace RFU.3) Replace IDU.

1717 Radio Alarm Yes Major RFU power failure (6Defective IF cable/connector.2) Defective RFU.3) Defective IDU.

1) Replace IF cable/connector.2) Replace RFU.3) Replace IDU.

1718 Radio Alarm Yes Major RFU power failure (6Defective IF cable/connector.2) Defective RFU.3) Defective IDU.

1) Replace IF cable/connector.2) Replace RFU.3) Replace IDU.

1719 Radio Alarm Yes Major RFU power failure (-Defective IF cable/connector.2) Defective RFU.3) Defective IDU.

1) Replace IF cable/connector.2) Replace RFU.3) Replace IDU.

1720 Radio Alarm Yes Major RFU power failure (Defective IF cable/connector.2) Defective RFU.3) Defective IDU.

1) Replace IF cable/connector.2) Replace RFU.3) Replace IDU.

1721 Radio Event Yes Indeterminate RFU reset

1722 Radio Alarm Yes Major RFU loopback is active User has activated RFU loopback. Disable RFU loopback.

1723 Radio Event Yes Indeterminate RFU mode changed toCombined

1724 Radio Event Yes Indeterminate RFU mode changed toDiversity

1725 Radio Event Yes Indeterminate RFU mode changed toMain

1726 Radio Alarm Yes Major RFU power supply failure At least one of the RFU's powersupply voltages is too low. Replace RFU.

1727 Radio Alarm Yes Warning RFU RX level out ofrange

RSL is very low (typically below -80dBm), link is down.For RFU-C:RSL is too low (typically below -83dBm) orRSL is too high (typically above -26dBm)

1) Check antenna alignment & linkplanning.2) Check link settings (TX power,TX frequency).3) Check antenna connections.4) Replace local/remote RFU.

1728 Radio Alarm Yes Warning RFU RX level path1 out ofrange

1) Improper installation.2) Fading event.3) Defective RFU.

1) Check that the fault is not due torain/multi-path fading or lack ofLOS.2) Check link settings (TX power,TX freq).3) Check antenna alignment. 4)Check antenna connections 5)Replace local/remote RFU.

1729 Radio Alarm Yes Warning RFU RX level path2 out ofrange

1) Improper installation.2) Fading event.3) Defective RFU.

1) Check that the fault is not due torain/multi-path fading or lack ofLOS.2) Check link settings (TX power,TX freq).3) Check antenna alignment. 4)Check antenna connections 5)Replace local/remote RFU.

1733 Radio Alarm Yes Major RFU synthesizerunlocked

At least one of the RFUsynthesizers is unlocked

1) Replace RFU.2) In XPIC mode, replace mateRFU as well.

1734 Radio Alarm Yes Minor RFU TX level out of range1) Defective RFU (the RFU cannottransmit the requested TX power)

1) Replace RFU.2) Intermediate solution - reduceTX power.

1735 Radio Alarm Yes Warning RFU TX Mute RFU Transmitter muted by user Unmute the RFU transmitter

1736 Radio Alarm Yes Major IDU SW does not supportthis type of RFU IDC SW does not support the RFU Upgrade IDC SW

1737 Management Event No Warning Card was extracted fromslot Card was extracted from slot NA

1738 Radio Alarm No Warning ATPC override trans User configuration

Change either atpc-override-tx-level or max-tx-level value so thatthe override value is less than orequal to the maximum value

1738 Management Alarm No Major Card is in Failure state Card is down as a result of cardfailure

1) Reset Card.2) Check if slot was disabled.

1739 Management Alarm No Critical FPGA Firmware file notfound

There is no FPGA file found on theMain Board for the card on the slot NA

1739 Radio Alarm No Warning ATPC overridden: Tx l

Actual transmitted signal level hasbeen at its maximum value forlonger than allowed.This is probably caused by aconfiguration error or link planningerror.

1) Correct the transmission levels2) The alarm will be cleared onlyupon manual clearing

1740 Management Alarm No Major Download card firmwarehas failed

Firmware download wasn'tsucceed

Reset Card.Download sw package.

Try to insert another Card.

1740 Radio Event No Warning MRMC running script isdeleted

New installed software packagedoes not include the runningMRMC radio script

1) Make sure the requires softwarepackage include the runningMRMC radio script.2) Download and install the correctsoftware package

1741 Management Event No Warning Card was inserted to slot Card was inserted to slot NA

1741 Radio Event No Warning MRMC running script isupdated

New installed software packagedoes has an updated version of therunning MRMC radio script

Reset the radio carrier to requirethe new updated MRMC radioscript

1742 Management Alarm No Major Card is in interconnectionfailure state

Card is down as a result of cardinterconnection failure

1) Reset Card.2) Check if slot was disabled

1743 Management Alarm No Major Expected Card is missingin slot

1) Card is missing.2) Expected Card Type configuredon empty slot.

1) Insert Expected Card.2) Clear Expected Card Type.

1744 Management Alarm No Major This Card type is notsupported in this slot

Existent Card is not belongsAllowed Card Types list for this slot

1) Reset.2) Insert Card belongs to AllowedCard Types list.

1745 Management Event No Indeterminate Card operational state isDown

Card state was change to Downstate NA

1746 Management Event No Indeterminate Card operational state isUp Card state was change to Up state NA

1747 Management Event No Indeterminate Card operational state isUp with Alarms

Card state was change to Up statebut with Alarms indication NA

1748 Management Alarm No Minor Unexpected Card Type inslot

Expected card type is different thanthe actual card type

1) Insert Expected Card.2) Change Expected Card Type.

1749 Management Event No Indeterminate Slot was Disabled The user Disabled slot NA

1750 Management Event No Indeterminate Slot was Enabled The user Enabled slot NA

1751 Management Event No Indeterminate Card on slot was Reset The user Reset slot NA

1752 Management Event No Warning FAN Card was extractedfrom slot FAN Card was extracted from slot

1753 Management Event No Major FAN failure

1754 Management Event No Warning FAN Card was inserted toslot FAN Card was inserted to slot

1755 Management Alarm No Major FAN Card is missing inslot

1) FAN Card is missing.2) Slot Enabled when Empty.

1) Insert FAN Card.2) Disable Slot.

1756 Management Alarm No Major Extreme Temperature System Temperature not inallowed range. NA

1757 Management Alarm No Major FAN Card is in Failurestate FAN Card is in Failure state Change FAN Card

1758 Management Event No Warning Power Supply wasextracted from slot

Power Supply was extracted fromslot

1759 Management Event No Warning Power Supply wasinserted to slot Power Supply was inserted to slot.

1760 Management Alarm No Major Power Supply is missingin slot

1) Power Supply is missing.2) Slot Enabled when Empty.

1) Insert Power Supply.2) Disable Slot.

1761 Management Alarm No Major Over voltage System Power Voltage higher thanallowed. NA

1762 Management Alarm No Major Under voltage System Power Voltage Lower thanallowed. NA

1763 Management Alarm No Warning The Main board firmwareis not found

1764 Management Alarm No Major Download Main Boardfirmware has failed

Firmware download wasn'tsucceed

Reset Board.Download sw package.Try to insert another Board.

1765 Management Event No Warning Main Board was reseted

1765 Management Event Yes Warning Unit Perform Power up

1766 Management Event Yes Warning RFU installation failure

1) Unsupported RFU type2) IDU-RFU communicationsproblem3) RFU failure

1) Make sure RFU is supported bySW version2) Check IDU-RFU cable3) Replace RFU

1767 Management Event Yes Warning RFU installation inprogress User command

1768 Management Event Yes Warning RFU installationsuccessfully completed User command

1800 Sync Alarm No Major T3 sync interface Loss ofCarrier

1) Cable disconnected.2) Defective cable.

1) Check connection of the cable.2) Replace the cable.

2001 Management Alarm Yes Major TDM-LIC has rebootedand is not in service now

1)Recent TDM-LIC card reset;2)System malfunction.

1) Wait for card to reboot2)Reset the TDM-LIC card.

2002 Management Alarm Yes Major TDM-LIC configurationmismatch

1) Recent warm reset of TDM-LIC;2) System malfunction. Power cycle the TDM-LIC.

2003 Sync Alarm Yes MajorLoss of Signal (LOS) onTDM-LIC's front panelclock port

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.4) Power cycle the TDM-LIC.

2004 Management Alarm Yes MinorCommunication withTDM-LIC is disrupted inHost-Card direction

System malfunction Reset the TDM-LIC.

2005 Management Alarm Yes Major TDM-LIC hardware failure System malfunction Reset the TDN-LIC.

2006 Management Alarm Yes Major No communication withTDM-LIC System malfunction Reset the TDM-LIC.

2007 Ethernet Alarm Yes Major Jitter-buffer-overrun alarmon TDM service.

Something wrong on TDM servicesynchronization. Check TDM service configuration

2008 Ethernet Alarm Yes Warning Late-frame alarm on TDMservice Something wrong on TDM service Check TDM service configuration

2009 Ethernet Alarm Yes Major Loss-of-frames alarm onTDM service

Failure along the network path ofTDM service

Check network or configuration forerrors in the network transport sideof the service

Malformed-frames alarm

1. Payload size does notcorrespond to the defined value

2010 Ethernet Alarm Yes Majoron TDM service. 2. Mismatch in PT value in RTP

header (if used) Check TDM service configuration

2011 Ethernet Alarm Yes Major Misconnection alarm onTDM service

Stray packets with wrong RTPconfigurations are received anddropped.

Check TDM service configuration

2012 TDM Alarm Yes MajorAlarm Indication Signal(AIS) on TDM-LIC TDMport

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.

2013 TDM Alarm Yes Major Loss Of Frame (LOF) onTDM-LIC TDM port

1) Line is not properly connected.2) External equipment is faulty.

2014 TDM Alarm Yes MajorLoss Of Multi-Frame(LOMF) on TDM-LIC TDMport

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.

2015 TDM Alarm Yes Warning Loopback on TDM-LICTDM port

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.

2016 TDM Alarm Yes Major Loss Of Signal (LOS) onTDM-LIC TDM port

1) Line is not properly connected;2) Cable is faulty;3) External equipment is faulty;4) Defective TDM-LIC.

1) Reconnect line.2) Check line cables.3) Check external equipment.

2017 TDM Alarm Yes MinorRemote Alarm Indication(RAI) on TDM-LIC TDMport

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.

2018 TDM Alarm Yes WarningE1/DS1 Unexpectedsignal on TDM-LIC TDMport

1) Port is disabled.2) Line is connected to a disabledport.

1) Enable relevant port.2) Disconnect cable from relevantport.

2019 Sync Alarm Yes Major PTP Clock 1588 Loss OfSynchronization

2020 Sync Alarm Yes Minor PTP Clock 1588squelching mode

SSM received pattern

2021 Sync Event No Warningchange was discovered

No action is required.

2022 TDM Alarm Yes Major Excessive BER on TDM-LIC STM1/OC3 port

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.4) Power cycle the TDM-LIC.

2023 TDM Alarm Yes Major Loss Of Frame (LOF) onTDM-LIC STM1/OC3 port

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.4) Power cycle the TDM-LIC.

2024 TDM Alarm Yes Warning Loopback on TDM-LICSTM1/OC3 port

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.4) Power cycle the TDM-LIC.

2025 TDM Alarm Yes Critical Loss Of Signal (LOS) onTDM-LIC STM1/OC3 port

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.4) Power cycle the TDM-LIC.

2026 TDM Alarm No Warning SFP is muted on TDM-LIC STM1/OC3 port

2027 TDM Alarm Yes Critical SFP absent on TDM-LICSTM1/OC3 port

1) SFP is not properly installed.2) SFP is faulty.

1) Install SFP properly.2) Replace the card.

2028 TDM Alarm Yes Critical SFP failure on TDM-LICSTM1/OC3 port

1) SFP is not properly installed.2) SFP is faulty.

1) Install SFP properly.2) Replace the card.

2029 TDM Alarm Yes Critical SFP transmit failure onTDM-LIC STM1/OC3 port

1) SFP is not properly installed.2) SFP is faulty.

1) Install SFP properly.2) Replace the card.

2030 TDM Alarm Yes Minor Signal Degrade on TDM-LIC STM1/OC3 port

1) Line is not properly connected.2) SFP is not properly installed.3) SFP is faulty.4) External equipment is faulty

1) Install SFP properly.2) Reconnect line.3) Check line cables.4) Check external equipment.5) Power cycle the TDM-LIC.

2031 TDM Alarm Yes MinorJ0 Trace IdentifierMismatch on TDM-LICSTM1/OC3 port

1) J0 misconfiguration2) Line is not properly connected.3) SFP is not properly installed.4) External equipment is faulty

1) Make sure expected andreceived J0 match2) Install SFP properly.3) Reconnect line.4) Check line cables.5) Check external equipment.6) Power cycle the TDM-LIC.

2032 TDM Event No WarningSSM pattern received onTDM-LIC STM1/OC3 portchanged

2033 TDM Alarm Yes MinorAlarm Indication Signal(AIS) on TDM-LICVC12/VT1.5

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.4) Power cycle the TDM-LIC.

2033 TDM Alarm Yes MinorLoss Of Pointer (LOP)received on TDM-LICVC12/VT1.5

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.4) Power cycle the TDM-LIC.

2034 TDM Alarm Yes Minor Excessive BER on TDM-LIC VC12/VT1.5

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.4) Power cycle the TDM-LIC.

2035 TDM Alarm Yes Warning Loopback on TDM-LICVC12/VT1.5

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.4) Power cycle the TDM-LIC.

2036 TDM Alarm Yes MinorPayload Mismatch Path(PLM) received on TDM-LIC VC12/VT1.5

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.4) Power cycle the TDM-LIC.

2037 TDM Alarm Yes MinorRemote Defect Indication(RDI) received on TDM-LIC VC12/VT1.5

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.4) Power cycle the TDM-LIC.

2038 TDM Alarm Yes MinorSignal Label Mismatch(SLM) received on TDM-LIC VC12/VT1.5

1) J2 misconfiguration2) Line is not properly connected.3) External equipment is faulty.

1) Make sure expected and receiveJ2 match2) Reconnect line.3) Check line cables.4) Check external equipment.5) Power cycle the TDM-LIC.

2039 TDM Alarm Yes Minor Signal Degrade on TDM-LIC VC12/VT1.5

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.4) Power cycle the TDM-LIC.

2040 TDM Alarm Yes Minor Unequipped on TDM-LICVC12/VT1.5

1) Line is not properly connected.2) External equipment is faulty.

1) Reconnect line.2) Check line cables.3) Check external equipment.4) Power cycle the TDM-LIC.

3000 Management Event Yes Warning Chassis was reset

5001 Ethernet Alarm Yes MinorERPI is either inprotection state or forcedprotection state

Either user "force switch"command or one of the ring linkshas failed

Either clear force command orrecover the link

5002 Ethernet Alarm No Warning More than a single RPL isconfigured in a ring User configuration Reconfigure the RPL

5010 Sync Alarm No Warning System is in sync forcemode state

5011 Sync Event No Major The sync-source qualitylevel was changed

5012 Sync Alarm No CriticalSystem SynchronizationReference in HoldoverMode

5013 Sync Event No Major The system's reference-quality changed