Data ONTAPUpgrades
Module 18
Data ONTAP 8.0 7-Mode
Administration
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 2/36
© 2009 NetApp. All rights reserved.
Module Objectives
By the end of this module, you should be able to:
Access the NOW™ site for the following documents:
– NetApp® Configuration Guide
– Data ONTAP® System Administration Guide
Locate hardware components using Parts Finder
Collect data for installation using a configurationworksheet
Interpret the network interface configuration
Set up console access for a storage system
Configure a storage system using the setup command
Describe how to perform Data ONTAP softwareupgrades and reboots
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 3/36
© 2009 NetApp. All rights reserved.
Boot Sequence
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 4/36
© 2009 NetApp. All rights reserved.
At the begin of the boot sequence, user may
press any key to abort and go to the firmware
prompt
Boot Sequence
CFE version 1.2.0 based on Broadcom CFE: 1.0.35
Copyright (C) 2000,2001,2002,2003 Broadcom Corporation.Portions Copyright (C) 2002,2003 Network Appliance Corporation.
CPU type 0x1040102: 600MHzTotal memory: 0x20000000 bytes (512MB)
Starting AUTOBOOT press any key to abort...Loading: 0xffffffff80001000/8659992 Entry at 0xffffffff80001000
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 5/36
© 2009 NetApp. All rights reserved.
Booting Data ONTAP 8.0
Firmware prompt
– CFE> or LOADER>
From the firmware prompt, the user may
perform several options:
– View or set environmental variables – Boot the storage system
boot_ontap
boot_primary
boot_backup boot_diags
– Netboot the storage system
Other tasks are beyond the scope of this course
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 6/36
© 2009 NetApp. All rights reserved.
Boot Sequence
As the storage system boots, press Ctrl-C to
display the special boot menu on the console
CFE version 1.2.0 based on Broadcom CFE: 1.0.35
Copyright (C) 2000,2001,2002,2003 Broadcom Corporation.
Portions Copyright (C) 2002,2003 Network Appliance Corporation.
CPU type 0x1040102: 600MHz
Total memory: 0x20000000 bytes (512MB)
Starting AUTOBOOT press any key to abort...
Loading: 0xffffffff80001000/8659992 Entry at 0xffffffff80001000
NetApp Data ONTAP Release 8.0 7-Mode
Copyright (C) 1992-2009 NetApp.All rights reserved.
*******************************
* *
* Press Ctrl-C for Boot Menu. *
* *
*******************************
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 7/36© 2009 NetApp. All rights reserved.
Accessing the Flash Boot Commands
As the storage system boots, the special boot
menu allows you to control the booting
sequenceBoot Menu will be available.
Please choose one of the following:
(1) Normal Boot.
(2) Boot without /etc/rc.
(3) Change password.
(4) Clean configuration and initialize all disks.
(5) Maintenance mode boot.(6) Update flash from backup config.
(7) Install new software first.
(8) Reboot node.
Selection (1-8)?
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 8/36© 2009 NetApp. All rights reserved.
Boot Sequence
As the storage system boots, if you do not press
Ctrl-C (or you select Normal boot), the system:
1. Loads the Data ONTAP kernel into physical memory
from a CompactFlash Card
2. Checks the root volume on the physical disk
...
Wed Apr 7 20:53:00 GMT [mgr.boot.reason_ok:notice]: System rebooted.
CIFS local server is running.
system> Wed Apr 7 20:53:01 GMT [console_login_mgr:info]: root logged
in from console
Wed Apr 7 20:53:23 GMT [NBNS03:info]: All CIFS name registrations
complete for local server
system>
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 9/36© 2009 NetApp. All rights reserved.
As the storage system boots and the Data ONTAP
kernel is loaded, it reads-in the following configurationand system files from the /etc directory
– /etc/rc file (boot initialization)
– /etc/registry file (option configurations)
– /etc/hosts file (local name resolution)
Wed Apr 7 20:52:50 GMT [fmmbx_instanceWorke:info]: Disk 0b.18 is a primary mailbox disk...Loading Volume vol0 Wed Apr 7 20:52:53 GMT [rc:notice]: The system was down for 64 seconds
Wed Apr 7 20:52:54 GMT [dfu.firmwareUpToDate:info]: Firmware is up-to-date on all disk drives Wed Apr 7 20:52:58 GMT [ltm_services:info]: Ethernet e0a: Link upadd net default: gateway 10.32.91.1 Wed Apr 7 20:53:00 GMT [mgr.boot.floppy_done:info]: NetApp Release 8.0
boot complete.
Boot Sequence (Cont.)
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 10/36© 2009 NetApp. All rights reserved.
Data ONTAP Upgrades
NetApp pre-installs Data ONTAP on all
shipped storage systems
As time goes by, you might want upgrade Data
ONTAP to a more current version
Types of upgrades: – Single system upgrade
– High-availability nondisruptive upgrade (NDU)
– Fresh install Always check the NOW site’s Data ONTAP
Upgrade Advisor for current information
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 11/36© 2009 NetApp. All rights reserved.
Data ONTAP Upgrade Advisor
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 12/36© 2009 NetApp. All rights reserved.
Upgrade Procedures
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 13/36© 2009 NetApp. All rights reserved.
Configuration Worksheet
e0
10.10.10.30
255.255.255.0
vif1
4e4a,e4b,e4c,e4d
eng_router
10.10.10.1OurDomain
10.10.10.100
10.10.10.200
10.10.10.100
Administrator
nollip
NetApp1
Joey
GMT
Bldg. 1
adminhost
10.10.10.20
en_US
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 14/36© 2009 NetApp. All rights reserved.
Single System Upgrade Steps
1. Review your current system hardware and licenses
2. Review all necessary documentation including:
– Data ONTAP Upgrade Guide and Data ONTAP Release
Notes for the destination version of Data ONTAP
– Review the NOW Bugs Online site for any known
installation and upgrade problems
3. Obtain the Data ONTAP upgrade image
4. Generate an AutoSupport e-mail
5. Install the software and download the new version to the
CompactFlash card
6. Reboot the system
7. Verify the install
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 15/36© 2009 NetApp. All rights reserved.
Single System Upgrade
Step 1: Review your current system hardware
and licenses:
– Use the sysconfig –a command to display a
hardware inventory of the system
– Use the version command to check your version of Data ONTAP and version –b to
check the current version of firmware
– Use the license command to see your current
licenses
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 16/36© 2009 NetApp. All rights reserved.
Single System Upgrade (Cont.)
Step 2: Review all necessary documentation
including:
– Data ONTAP Upgrade Guide and Data ONTAP
Release Notes for the destination version of Data
ONTAP
– Review the NOW Bugs Online site for any known
installation and upgrade problems
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 17/36© 2009 NetApp. All rights reserved.
Single System Upgrade (Cont.)
Step 3: Obtain the Data ONTAP upgrade
image for the appropriate storage system
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 18/36© 2009 NetApp. All rights reserved.
ZIP or TGZ
NetApp is releasing two different formats of
Data ONTAP 8.0:
– ZIP is used when upgrading from Data ONTAP
7.3
– TGZ is used when doing a fresh install or whenperforming incremental updates after Data
ONTAP 8.0
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 19/36© 2009 NetApp. All rights reserved.
Single System Upgrade (Cont.)
Step 4: Generate an AutoSupport e-mail
system> options autosupport.doit“starting_upgrade_from_7.3_to_8.0”
NOTE: This step is not necessary because
since Data ONTAP 7.2.4,
the notification is sent automatically
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 20/36© 2009 NetApp. All rights reserved.
Single System Upgrade (Cont.)
Step 5: Use the software command to install
the software and download the new version to
the CompactFlash card:
– From the storage system prompt, enter the command to
extract and install Data ONTAP system files from the
upgrade package
system> software updatehttp://10.254.134.39/image.zip -d -r
– The download command can take a considerable
amount of time to run. It can take as long as60 minutes to complete
system> download
– Verify compact flash is updated
system> version -b
+20mins
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 21/36© 2009 NetApp. All rights reserved.
Single System Upgrade (Cont.)
Step 6: Reboot the system
– Use the reboot command to halt a system and automaticallyreboot it:system> reboot [–t interval]
– Use the halt command to shut down a storage system and
boot at the firmware prompt:system> halt [–t interval]
CFE or LOADER> boot_ontap
Step 7: Verify the install – Administrators can use the version command or
sysconfig to verify the new version of Data ONTAP that is
running
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 22/36
© 2009 NetApp. All rights reserved.
X 2
X 2
SHELF
ID
1 Gb 4 Gb
A
B1 2
2Gb
3
2 G b
E S H 4
4 G b 1 G b E L P
2Gb
ESH4
4Gb 1Gb ELP
X 2
X 2
SHELF
ID
1 Gb 4 Gb
A
B1 2
2Gb
3
2 G b
E S H 4
4 G b 1 G b E L P
2Gb
ESH4
4Gb 1Gb ELP
Nondisruptive Upgrades (NDU)
– For more information, please
see the High Availability
web-based course
8 975 642 31
8 975 642 31
e0e e0f
e0a e0b e0c e0dRLM
L N K
L N K
L N K
L N K
0f 0e 0g 0h
L N K
L N K
L N K
L N K
0b0a 0c 0d
2HI-POT
2200VDC1HI-POT
2200VDC
REPLACE THIS ITEMWITHIN 2 MINUTES OF
REMOVAL
REPLACE THIS ITEMWITHIN 2 MINUTES OF
REMOVAL
PROPERLY SHUTDOWNSYSTEM BEFORE OPENING CHASSIS.
ACIN PWR ACIN PWR
8 975 642 31
8 975 642 31
e0e e0f
e0a e0b e0c e0dRLM
L N K
L N K
L N K
L N K
0f 0e 0g 0h
L N K
L N K
L N K
L N K
0b0a 0c 0d
2HI-POT
2200VDC1HI-POT
2200VDC
REPLACETHISITEMWITHIN2MINUTESOF
REMOVAL
REPLACETHISITEMWITHIN2MINUTESOF
REMOVAL
PROPERLYSHUTDOWN SYSTEMBEFORE OPENINGCHASSIS.
ACIN PWR ACIN PWR
NDU includes:
– Disk & shelf firmware
updates
– Data ONTAP updates
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 23/36
© 2009 NetApp. All rights reserved.
Storage Controller NDU
Before you attempt to perform a storage controller NDU:
Review all necessary documentation including:
Data ONTAP Upgrade Guide and Release Notes for the
destination version of Data ONTAP
Review the NOW Bugs Online site for any known installation
and upgrade problems Validate the high-availability controller configuration
Remove all failed disks to allow giveback operations to
succeed
Upgrade disk and shelf firmware as discussed earlier in this module
Verify that system loads are within the acceptablerange; load should less than 50% on each system
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 24/36
© 2009 NetApp. All rights reserved.
X 2
X 2
SHELFID
1 Gb 4 Gb
A
B1 2
2Gb
3
2 G b
E S H 4
4 G b 1 G b E L P
2Gb
ESH4
4Gb 1Gb ELP
X 2
X 2
SHELFID
1 Gb 4 Gb
A
B1 2
2Gb
3
2 G b
E S H 4
4 G b 1 G b E L P
2Gb
ESH4
4Gb 1Gb ELP
Nondisruptive Upgrades (NDU)
8 975 642 31
8 975 642 31
e0e e0f
e0a e0b e0c e0dRLM
L N K
L N K
L N K
L N K
0f 0e 0g 0h
L N K
L N K
L N K
L N K
0b0a 0c 0d
2HI-POT
2200VDC1HI-POT
2200VDC
REPLACETHISITEM
WITHIN2MINUTESOF
REMOVAL
REPLACETHISITEM
WITHIN2MINUTESOF
REMOVAL
PROPERLYSHUTDOWN SYSTEMBEFORE OPENINGCHASSIS.
ACIN PWR ACIN PWR
8 975 642 31
8 975 642 31
e0e e0f
e0a e0b e0c e0dRLM
L N K
L N K
L N K
L N K
0f 0e 0g 0h
L N K
L N K
L N K
L N K
0b0a 0c 0d
2HI-POT
2200VDC1HI-POT
2200VDC
REPLACETHISITEMWITHIN2MINUTESOF
REMOVAL
REPLACETHISITEMWITHIN2MINUTESOF
REMOVAL
PROPERLYSHUTDOWN SYSTEMBEFORE OPENINGCHASSIS.
ACIN PWR ACIN PWR
Data ONTAP 7.3.1 Data ONTAP 7.3.1
Data ONTAP 8.0 Data ONTAP 8.0
1. Both storage systems start off with an older version of Data ONTAP
2. Install and download the new version of Data ONTAP on both systems
3. Reboot the first system; the second system will take over for the first
4. Give back to the first system; then reboot the second system
5. Give back to the second system; both systems run a new version
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 25/36
© 2009 NetApp. All rights reserved.
Data ONTAP 8.0 7-Mode Fresh Installs
Step 1: Install and download Data ONTAP on
the boot device and CompactFlash drive
Step 2: Interrupt reboot and choose(4) Clean configuration and initialize all disks
from the boot menu Step 3: System should boot and go into setup
For more information see the Data ONTAP 8.0
System Administration Guide
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 26/36
© 2009 NetApp. All rights reserved.
Setup
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 27/36
© 2009 NetApp. All rights reserved.
Using the Setup Script
Runs automatically during initial system
configuration
Use the configuration worksheet to prepare
Run script at any time
– Use to change existing configuration
Reboot for changes to take effect
– Alternative to a reboot:
system> source /etc/rc
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 28/36
© 2009 NetApp. All rights reserved.
The setup Script
system> setup
The setup command will rewrite the /etc/rc, /etc/exports,/etc/hosts, /etc/hosts.equiv, /etc/dgateways, /etc/nsswitch.conf,
and /etc/resolv.conf files, saving the original contents of
these files in .bak files (e.g. /etc/exports.bak).
Are you sure you want to continue? [yes] y
NetApp Release Release 8.0 7-Mode
System ID: 0101173126 (system); partner ID: 0101169724 (system2)
System Serial Number: 1056850 (system)
System Rev: C0
System Storage Configuration: Single-Path HA
slot 0: System BoardProcessors: 4
Processor type: Intel Xeon
Memory Size: 4096 MB
...
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 29/36
© 2009 NetApp. All rights reserved.
The setup Script
Please enter the new hostname [system]:
Do you want to configure interface groups? [n]:
Please enter the IP address for Network Interface e0a [10.254.134.36]:
Please enter the netmask for Network Interface e0a [255.255.252.0]:
Should interface e0a take over a partner IP address during failover?
[n]:Please enter media type for e0a {100tx-fd, tp-fd, 100tx, tp, auto
(10/100/1000)} [auto]:
Please enter flow control for e0a {none, receive, send, full} [full]:
Do you want e0a to support jumbo frames? [n]:
... e0b, e0c, and e0d interfaces as well ...
Would you like to continue setup through the web interface? [n]:
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 30/36
© 2009 NetApp. All rights reserved.
The setup Script
Please enter the name or IP address of the default gateway
[10.254.132.1]:
The administration host is given root access to the filer's
/etc files for system administration. To allow /etc root access
to all NFS clients enter RETURN below.
Please enter the name or IP address of the administration host:
Please enter timezone [GMT]:
Where is the filer located? []:What language will be used for multi-protocol files (Type ? for
list)?:
language not set
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 31/36
© 2009 NetApp. All rights reserved.
The setup Script
Do you want to run DNS resolver? [n]: y
Please enter DNS domain name [development.netappu.com]:You may enter up to 3 nameservers
Please enter the IP address for first nameserver [10.254.132.10]:
Do you want another nameserver? [y]:
Please enter the IP address for alternate nameserver [10.254.134.25]:
Do you want another nameserver? [n]:
Do you want to run NIS client? [n]:
The initial aggregate currently contains 3 disks; you may add
more
disks to it later using the "aggr add" command.
Now type 'reboot' for changes to take effect.
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 32/36
© 2009 NetApp. All rights reserved.
Check Software Version & License Status
system> version
NetApp Release 8.0: Fri May 8 01:32:17 PDT 2009
system> sysconfig -v
NetApp Release Release 8.0 7-Mode
System ID: 0101173126 (system); partner ID: 0101169724 (system2)
System Serial Number: 1056850 (system)
System Rev: C0
System Storage Configuration: Single-Path HA
slot 0: System Board
Processors: 4
Processor type: Intel Xeon
Memory Size: 4096 MB
...
system> license
...
cf not licensed
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 33/36
© 2009 NetApp. All rights reserved.
Module Summary
In this module, you should have learned:
Access the NOW™ site for the following documents: – NetApp® Configuration Guide
– Data ONTAP® System Administration Guide
Locate hardware components using Parts Finder
Collect data for installation using a configurationworksheet
Interpret the network interface configuration
Set up console access for a storage system
Configure a storage system using the setup command
Describe how to perform Data ONTAP softwareupgrades and reboots
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 34/36
Exercise
Module 18: Data ONTAP Upgrades
Estimated Time: 90 minutes
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 35/36
Answers
Module 18: Data ONTAP Upgrades
7/27/2019 M18-DataONTAPUpgrades
http://slidepdf.com/reader/full/m18-dataontapupgrades 36/36
Check Your Understanding
What is the name of the worksheet which aids in the
set up of your storage system and where do you findit?
– The Configuration Worksheet
What command simplifies Data ONTAP upgrades?
– software update