Lumiere - Matallic epoxy flooring system e

download Lumiere - Matallic epoxy flooring system e

of 2

Transcript of Lumiere - Matallic epoxy flooring system e

  • 8/14/2019 Lumiere - Matallic epoxy flooring system e

    1/2

    engineered to per orm

    Architectural specifcations available upon request.

    toll ree 1.866.835.6595 ax 1.866.629.4157 duraamen.com

    lmieremetallic epoxy ooring system

    Lmiere is a premium quality epoxy ooring system that is available in bright metallic fnishes. It has metallic integral pigment that gives

    a variegated three-dimensional appearance. Typically it is coated with polyaspartic sealer that results in a high-per ormance, chemicaland abrasion resistant, easy to clean and virtually maintenance- ree ooring system.

    the lmiere system requires the application o :a . Perdre E02, 100% solids epoxy primer

    b . Lmiere , 100% solids metallic epoxy applied at 18-20mil thicknessc . Perdre P70 , 98% solids polyaspartic topcoat

    usesShowrooms / Retail stores

    Restaurants

    Casinos

    Entertainment centers

    Malls and Super Stores

    Dance oors

    Tattoo parlors

    Ca eterias,Ice cream parlors

    Hair salons

    O fce spaces / reception areas

    Garage oors,Entertainment / Living rooms / Basements

    eatures & beneftsExcellent clarity and three-dimensional appearance

    Very high compressive strength, 11,000psi

    Low odor during application, can be applied inoccupied spaces

    Low viscosity; easy spreading and wetting properties

    Superior adhesion and excellent abrasion and chemicalresistance

    Available as a ast cure option or speedy application

    available colors

    bronze bright silver brass antique silver copper

  • 8/14/2019 Lumiere - Matallic epoxy flooring system e

    2/2

    engineered to per orm

    toll ree 1.866.835.6595 ax 1.866.629.4157 duraamen.com

    lmieremetallic epoxy ooring system

    lmiere system applicationThe application o the Lmiere system involves the ollowing steps:

    1. application o primerThe substrate is prepared per the guidelines given in the Draamen technical

    bulletin-1 and then one coat o the primer Perdre E02 is applied with a shortnap roller. The primer ensures ma ximum adhesion to the substrate and prevents

    outgassing and air bubbling in the fnished system. Perdre E02 is a 100% solids, moisture-tolerant epoxy primer or concrete a nd

    masonry sur aces. It combines the properties o water insensitivity and goodwetting properties. A ter the application o primer, it is allowed to cure or at least6-8 hours be ore the application o Lmiere body coat.

    2. application o lmiere a . Mixing

    I. Thoroughly mix each component separately prior to mixing with each other.

    II. Mix 4 parts o A with 1 part o B by volume or three minutes with a low speedelectric drill mixing paddle.

    III. Do not mix more material that can be used in 30 minutes.

    b . ApplicationI. Pour material on the oor in a line and spread with a at/notched squeegee or

    trowel to a coverage o 160 t 2 /gal. to achieve a thickness o 10-12mil.II. Back roll with a short nap roller to even the sur ace texture o

    the coating.

    III. Allow material to cure or 14-16 hours be ore applying the second coat. Twocoats are required unless a single coat is applied at least 18-20mil thick.

    IV. Second coat (OPTIONAL): Mix and apply as be ore. I the second coat isback rolled, be aware that the roller pattern may be visible. While the materialis still wet, lightly mist sur ace with dispersing agent (acetone or Xylene, etc.)with a sprayer to cre ate special e ects. A carbon dioxide powered sprayeris a better option to avoid unwanted drips. Experimentation is necessar y todetermine how long to wait be ore spraying dispersing agent, based on such

    actors as temperature, amount o solvent, type o solvent, etc. Spray toosoon and the epoxy will ow back to its original appearance. I sprayed toolate the Lmiere will not be a ected by the solvent mist.

    V. The Lmiere is allowed to cure for at least 24 hours before the application of top coat.

    3. application o topcoat a. Use Perdre P70 for sealing the Lmiere system.

    Perdre P70 , 98% solids polyaspartic sealer is applied as a protective top coatover Lmiere body coat. Perdre P70 is a next generation aliphatic polyasparticpolyurea designed to provide high gloss, UV stable (non-yellowing), chemical andabrasion resistant protection. Perdre P70 has very low odor and can be appliedindoors in occupied areas.

    technical dataTensile Strength (ASTMD-638)

    8,500psi

    Adhesion to Concrete(ACI 403)

    350psi(100% concrete ailure)

    Hardness (ASTM D-2240) 80 (Shore D)

    Flexural Strength (ASTMD-790)

    8,000psi

    Compressive Strength(ASTM D-695)

    11,000psi

    Service Temperature 150F

    Water absorption (ASTMD-670-73) 0.10% maximum

    Viscosity @ 75F 750-1000cps

    Mixing ratio 4 (Part A) : 1 (part B)

    Solids Content 100% by volume

    VOC

    Gloss, 60F 100-110

    Density 9.0-9.70lb/gal.

    Pot li e 30-40min @ 75F

    Dry to touch 10-14hours @ 75F

    Recoat 14-16hours @ 75F

    Light tra fc 24hours @ 75F

    Full cure & Maximum

    Resistance

    5 days

    Photos courtesy of Garage and Beyond