LT5050 2000 plus and 2000 plus xtra remote ISS 14 (benchmark)
Transcript of LT5050 2000 plus and 2000 plus xtra remote ISS 14 (benchmark)
Owner’s Manual
INCLUDES
User, Maintenance, Service, and Installation
Instructions
PARAGON 2000 Plus & 2000 Plus Xtra Remote
Keep this booklet for service log and future reference
For use in Great Britain and Ireland.
Literature NO 5050 (ISS 14)
IMPORTANT
This appliance is guaranteed for 12 months subject to conditions. The 5 year extended parts
warranty will only be valid if the annual service recommended in this manual has been
completed and appliance has been registered online.
Contents
EXTENDED FIVE YEAR PARTS WARRANTY .................... 2
Benchmark Scheme ..................................................... 3
SECTION ONE Introduction (user instructions) .. Error!
Bookmark not defined.
SECTION TWO Operating the Appliance (user
instructions) .................. Error! Bookmark not defined.
SECTION THREE Cleaning (user instructions) ...... Error!
Bookmark not defined.
SECTION FOUR Fuel Bed Cleaning and Layout (user
instructions) .................. Error! Bookmark not defined.
SECTION FIVE General Points (user instructions)Error!
Bookmark not defined.
SECTION SIX Appliance Data (installation
instructions) .................. Error! Bookmark not defined.
SECTION SEVEN Regulations and Warnings
(installation instructions) ............ Error! Bookmark not
defined.
SECTION EIGHT Siting the Appliance (installation
instructions) .................. Error! Bookmark not defined.
SECTION NINE To Install the Appliance (installation
instructions) .................. Error! Bookmark not defined.
SECTION TEN Checking Operation of Fire (installation
instructions) .................. Error! Bookmark not defined.
SECTION ELEVEN Maintenance (maintenance
instructions) .................. Error! Bookmark not defined.
GAS FIRE COMMISSIONING CHECKLIST ..................... 30
SERVICE RECORD ........................................................ 31
EXTENDED FIVE YEAR
PARTS WARRANTY
In order to validate your extended 5 years parts
warranty please read the Benchmark Scheme on the
opposite page and ensure your installer has filled in the
appropriate checklist.
This in no way reduces your statutory rights
Your warranty commences from the date of purchase
and you must retain your receipt or invoice as proof of
a purchase date.
THIS EXTENDED WARRANTY SPECIFICALLY EXCLUDES
GLASS AND SOFT REFRACTORY COMPONENTS, THE BULB
AND ANY BATTERIES.
Terms and Conditions
1. The appliance must be installed by a GAS SAFE
registered person.
2. The appliance must be used in accordance with
the user’s instructions.
3. The appliance must be serviced annually by a GAS
SAFE registered person.
4. The benchmark and service log must be correctly
filled out and the record of annual services must be up
to date and supported by receipts in each case.
5. This warranty is not transferable and relates to the
original installation only.
6. The appliance has not been subjected to misuse or
accident or been modified or repaired by any
person other than the authorised employee or
authorised representative of Charlton and Jenrick
Ltd.
7. The registration form must be returned within 1
month of purchase.
Technical Help Desk 01952 200 444
Benchmark Scheme
Charlton and Jenrick Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of
installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular
servicing to optimise safety, efficiency and performance. Benchmark is managed and promoted by the Heating and
Hotwater Industry Council. For more information and the full code of practice please visit www.centralheating.co.uk
Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the
installation instructions supplied with the product and that you have signed it to say that you have received a full
and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a
means of complying with the appropriate Building Regulations (England and Wales).
All installations must be notified to Local Area Building Control either directly or through a Competent Persons
Scheme. A Building Regulations Compliance Certificate will then be issued to the customer who should, on receipt,
write the Notification Number on the Benchmark Checklist.
This product should be serviced regularly to optimise its safety, efficiency and performance. The service engineer
should complete the relevant Service Record on the Benchmark Checklist after each service.
The Benchmark Checklist will be required in the event of any warranty.
It is a requirement that the gas fire is installed and commissioned to the manufacturer’s instructions and the data
fields on the commissioning checklist completed in full.
To instigate the guarantee, the gas fire needs to be registered with the manufacturer within one month of the
installation.
To maintain the guarantee, it is essential that the gas fire is serviced annually by a Gas Safe registered engineer. The
service details should be recorded on the Benchmark Service Interval Record and left with the householder.
4 LT5050 (ISS 14)
Important
For future reference we suggest you record the following details here, and keep the receipt as proof of purchase.
This information may be asked for when you contact the helpdesk.
MODEL: 2000 Plus REMOTE Serial No.
This information can be found on the label attached to the packaging and on the data badge, which is located on
the base of the appliance behind the control cover.
Retailer Name:
Address:
Date Of Purchase:
www.charltonandjenrick.co.uk 5 LT5050 (ISS 14)
SECTION ONE Introduction (user instructions)
Consumer Protection Information
As manufacturers and suppliers of heating products, we take every care, as far as is reasonably practicable, that
these products are so designed and constructed as to meet the general safety requirement when properly used
and installed. To this end, our products are thoroughly tested and examined before despatch.
IMPORTANT NOTICE: Any alteration that is not approved by the appliance manufacturer could invalidate the
approval of the appliance, operation of the warranty and could affect your statutory rights.
Health and Safety Notice
Important: This appliance could contain some of the materials, indicated below, that could be interpreted as being
injurious to health and safety. It is the users / installers responsibility to ensure that the necessary personal
protective clothing is worn when handling these materials, see below for information.
Artificial Fuels, Mineral Wool, Insulation Material, Refractory/Ceramic Fibres, Glass Yarn - may be harmful if
inhaled, may be irritating to skin, eyes, nose and throat.
When handling avoid inhaling and contact with skin or eyes. Use disposable gloves, facemasks and eye protection.
After handling wash hands and other exposed parts. If a vacuum is used for cleaning the fuel bed or cleaning after
servicing / installation it is recommended that it be of the type fitted with a HEPA filter.
Disposal of refractory/ceramic materials. To keep dust to a minimum these materials should be securely wrapped
in polythene and be clearly labelled ‘RCF waste’. These materials are not classified as ‘hazardous waste and should
be disposed of at a site licensed for the disposal of industrial waste.
INTRODUCTION
• The PARAGON 2000 Plus Remote as been designed and tested to the requirements of EN 509 and is suitable
for use in GB (Great Britain) and IE (Ireland).
• The PARAGON 2000 Plus Remote incorporates a single gas control, which selects ignition pilot, with variable
setting between low and high settings. The appliance is operated via a remote control hand set.
• This appliance is intended for decorative purposes.
• The PARAGON 2000 Plus Remote is available in two versions Natural Gas or LPG (Propane Gas Only). The
markings (G20 for natural gas or G31 for propane) on the packaging and the data badge specify the gas for
which the appliance has been factory set. Note: These appliances should only be used on the appropriate gas
specified. They are not suitable for conversion from one gas to the other.
• The pilot can be left on (standby setting) or the pilot can be extinguished and relit each time the fire is used.
• Like all appliances incorporating an aerated burner a low frequency noise may be heard, this may be more
noticeable on the low setting.
• The chimney or flue (unless new) must be swept before installation if it has been used for solid fuel.
• It is advised that this appliance is serviced annually, this is more likely to provide trouble-free operation.
• This appliance has a naked flame, as with all such fires it is recommended that a fireguard should be used for
the protection of children, the elderly and infirm. Fireguards should conform to BS 6539 (1984) (Fireguards for
use with solid fuel appliances).
6 LT5050 (ISS 14)
The PARAGON 2000 Plus R is battery operated; therefore no mains electrical supply is required. Power to the
appliance is provided by 6 high power alkaline 1.5V batteries (AA size) (a spare set of 6 AA batteries is supplied
with the appliance); these batteries can be changed to Nickel Metal Hydride rechargeable batteries providing they
have a minimum capacity of 2200 mAh. A set of 6 high power alkaline 1.5V batteries (AA size) would give in the
order of 200 -380 operations while 6 rechargeable batteries when fully charged would give approximately 200-
300 operations. These figures are only given for guidance and may vary depending on how the appliance is used
and the battery manufacturer and quality.
Using the standby facility when the appliance is switched off for short periods can extend battery life. The standby
facility switches off the mains gas supply to the appliance but the pilot remains alight.
An audible repeated bleep warning indicates that the appliance batteries need changing or charging (if
rechargeable batteries have been used).
Important: Batteries should be changed or recharged as soon as possible as the appliance will not light if the
battery power gets too low.
The appliance incorporates a safety device in the form of an Oxygen Depletion System, which constantly monitors
the oxygen in the room and will cause the fire to switch off if the oxygen level reduces, for instance due to
insufficient ventilation or a blocked flue.
If this regularly occurs do not attempt to relight the appliance until a qualified engineer has checked it, the
problem may not be due to lack of air or a defective flue.
A fire front (fret) must be used with this appliance.
In GB, the appliance must be installed by a competent person i.e. Gas Safe-registered, in accordance with the GAS
SAFETY (INSTALLATION AND USE) REGULATIONS, The Building Regulations (or The Building Regulations (Scotland)
or The Building Regulations (Northern Ireland)) and The Current I.E.E. Wiring Regulations, if appropriate.
In IE, the appliance must be installed by a competent person and installed in accordance with the current edition
of I.S.813 Domestic Gas Installation, the current Building Regulations and the current ETCI rules for electrical
installation ,if appropriate.
In the Republic of Ireland, permanent ventilation must be provided in accordance with the regulation in force (I.S.
813).
It is important that: -
The chimney or flue is checked annually to ensure clearance of combustion products.
Any purpose-built ventilation should be checked periodically to ensure freedom from obstruction.
Any debris from the chimney or flue should be removed. The fire should be allowed to cool for three to four
hours before removing debris.
Rubbish must not be thrown onto the coal/pebble bed under any circumstances.
The cast fire front must be positioned in front of the fire whilst it is burning.
www.charltonandjenrick.co.uk 7 LT5050 (ISS 14)
Warning:- This appliance has a naked flame, has with all fires it is recommended that a
fireguard should be used for the protection of children, the elderly and infirm.
Fireguards should conform to BS 6539 (1984) (fireguards for use with solid fuel appliances).
During the normal operation of the fire some black staining may appear on some parts of the fuel bed. This is
quite normal and adds to the appearance of the appliance. However, if excessive black staining does occur it may
be due to the fuel bed being incorrectly laid. This should be checked against the Fuel Bed Layout in Section Three,
prior to contacting a service engineer.
Pilot Cleaning (Before cleaning ensure that the appliance is turned off and cold)
In some instances you may experience ignition problems even when the appliance
is new. This may be due to the aeration hole in the pilot body (see photograph)
being partial blocked with dust, pet hairs or other foreign matter. The source of
this debris could be such things as carpet fibres, decorating or pets etc.
To clean the pilot, remove the fire front and ashpan. The pilot is located on
the right hand side of the appliance, any debris in or around the aeration
hole should be removed using the nozzle of a vacuum cleaner. It is
advisable not to blow the debris into the hole as this may cause more of a
restriction and not rectify the problem.
Fret
A Fret must be used with this appliance, and must conform to the following: -
• It must be made from non-combustible material.
• Its general construction should enable it to stand firmly across the full width of the
• burner.
• The design of the fire front (fret) must have a removable ash-pan cover (lower section).
• The ashpan cover must have cut-outs and or holes which provide ventilation to the underside of the burner.
• The effective area of ventilation through the ash-pan cover must be greater than 1365mm2 (2.12 sq. ins.)
8 LT5050 (ISS 14)
SECTION TWO Operating the Appliance (user instructions) Before attempting to operate the appliance check that nothing
has been placed in front of the appliance that may interfere with
the remote sensor operation.
To light the appliance using the remote hand set:
A. Point the remote control hand set in the direction of the
appliance and simultaneously press the buttons marked ‘
OFF’ and ‘standby’. Continue to hold in these two
buttons until a ‘bleep’ is heard (approximately 2-3 sec.)
and then release these buttons. The appliance will
automatically go through the ignition sequence and the
pilot should ignite. Once the pilot is alight the appliance
will automatically go to the high setting (approximately
20-25sec). If the ignitor stops sparking and the pilot fails
to light, repeat this procedure.
B. The appliance can be adjusted up or down by pressing the appropriate button ' '
(low setting) or ' '
(high setting).There are 5 heat settings and the fire will give a double bleep when the maximum or
minimum heat setting is reached. To switch off the appliance press the OFF ' '
button or if the appliance
is to be switch off for a short period it is recommended that the ‘standby’ button be used. This switches
the main burner off but leaves the pilot on and will extend battery life.
C. The appliance can be switched off without using the hand set by removing the appliance batteries located
behind the ash pan cover. When the batteries are removed there will be a delay (up to 3minutes) after
which double bleeps may be heard and shortly after the appliance will extinguish. Ensure that the battery
is reconnected once the fire as been extinguished. The appliance cannot be operated without the use of
the handset. If the fire fails to light or extinguishes for any reason, it will be necessary to re-set the fire.
This can be done by pressing the OFF button then following the normal lighting procedure.
NOTE: If the fire is extinguished for any reason wait 3 minutes before relighting.
www.charltonandjenrick.co.uk 9 LT5050 (ISS 14)
Low Battery Indication (Hand Set)
If while pressing any of the buttons on the remote hand
set the low battery indicator lamp either stops flashing or
appreciably slows then the battery should be changed.
To Replace Batteries In Hand SET (aaa 1.5 v lr3 X2)
Remove the cover from the rear of the handset and fit
replacement batteries, taking care not to strain the
battery connections.
LOW BATTERY INDICATION (APPLIANCE)
If you hear a repeated ‘bleep’ sound come from the appliance this indicates the appliance battery pack is low and
should be changed as soon as possible. The appliance will continue to work normally for a short period but if the
warning is ignored you may experience difficulty lighting the appliance or the appliance may automatically switch
off for no apparent reason.
NOTE: The appliance cannot be used when the battery is completely flat.
TO REPLACE APPLIANCE BATTERIES (6 High Power Alkaline AA 1.5V)
(Rechargeable batteries can be used providing they are a nickel metal hydride type 1.5V AA with a minimum
capacity of 2200mAh).Using AA Lithium batteries will give more operations.
A. Lift off fret and ash pan.
B. The battery power pack or holder is located at the left hand side of
the burner; carefully slide the battery holder forward and replace
all six batteries as a complete set or recharge as appropriate.
WARNING, batteries will overheat if fitted incorrectly, when
fitting the batteries ensure that they are fitted as per the marking
on the rear of the holder (i.e. minus of battery against spring). If
rechargeable batteries are used they MUST be a Nickel Metal
Hydride type with a minimum capacity of 2200mAh.
C. Important: Place the battery pack or holder inside the insulation
blanket and ensure that it is placed to the left hand side of the appliance as shown and refit fret and ash
pan cover.
D. Once the new batteries are loaded the fire will continue to bleep until re-set. This can be done by
pressing the “off “ button on the handset followed by the normal ignition sequence as above. If the fire
continues to bleep this may indicate a loose connection or badly loaded batteries.
10 LT5050 (ISS 14)
SECTION THREE Fuel Bed Cleaning and Layout (user instructions)
Important: - Refer to the Health & Safety Notice located on page 5 of this booklet before cleaning or replacing
any refractory material.
The fuel bed components are delicate and they should be handled with great care.
The loose parts and moulded shapes may be removed for cleaning. They can be brushed very gently
with a soft brush to remove dust or any deposits.
A vacuum cleaner may only be used after the loose components and moulded shapes have been
removed.
CARE SHOULD BE TAKEN TO AVOID CONTACT WITH THE REFRACTORY LINING THIS IS A
DELICATE SURFACE AND SHOULD NOT BE WIPED OR RUBBED.
FUEL BED LAYOUT (COAL OPTION)
• Ensure the BASE MATRIX is in position as shown
located against the rear edge of the burner outlet
• Locate the LEFT HAND and RIGHT HAND FRONT
COALS as shown so that they sit on the front rail
and lean back against the BASE MATRIX. Note it is
most important that they are located in their
correct positions. They are marked on the rear "L"
for LEFT HAND FRONT COAL and "R" for RIGHT
HAND FRONT COAL.
www.charltonandjenrick.co.uk 11 LT5050 (ISS 14)
Note the loose coal provided consist of :-
• 5 off shaped as coal "A"
• 9 off shaped as coal "B"
Separate the coal into the two size groups
• Lay first row of loose coal 4 off "B" and 2 off "A"
coals as shown so that they bridge across the gap
• Lay second row of loose coals “B” and “A” shapes
as shown.
12 LT5050 (ISS 14)
• Lay third row of loose coals “B” and “A” shapes as
shown.
FUEL BED LAYOUT (PEBBLE OPTION)
Fuel Bed Components
• Base Matrix
• L & R Front Pebbles
• Numbered Pebbles & Colours as below:-
PEBBLE LAYOUT
Warning
Take great care when positioning the pebbles to
avoid marking the black linings.
• Ensure the BASE MATRIX is in position as shown
located against the rear edge of the burner outlet.
Pebble identification
QTY
Heart Shape 1
Oblong Shape 4
Large Shape 3
Medium Shape 2
Small Shape 2
Total 12
www.charltonandjenrick.co.uk 13 LT5050 (ISS 14)
• Locate the LEFT HAND and RIGHT HAND
FRONT PEBBLES as shown so that they sit on
the front rail and lean back against the BASE
MATRIX. Note it is most important that they
are located in their correct positions. They are
marked on the rear "L" for LEFT HAND FRONT
PEBBLE and "R" for RIGHT HAND FRONT
PEBBLE.
• Lay one row of pebbles at the front of the fire as
shown. A second row (number positioned against
the rear of fire) is placed between the base
matrix and the rear of the fire as shown.
• Lay another row of loose pebbles shown.
14 LT5050 (ISS 14)
• Lay another row of loose pebbles as shown.
SECTION FOUR Important Information (user instructions)
The only user removable parts are: -
• The loose pebbles, coals .
• The left hand front pebble, coal shape.
• The right hand front pebble, coal shape.
• The base matrix
• Cast Fret
• Decorative Trim
Like all appliances incorporating an aerated burner a low frequency noise may be heard, particularly on the
low setting, this is quite normal and does not affect the operation of the appliance.
Servicing
It is advised that the PARAGON 2000 Remote fire is serviced annually this is more likely to provide trouble-
free operation. A competent person must carry this out, i.e .Gas Safe Registered Installer in accordance
with the current Gas Safety (Installation and Use) Regulations 1998 (as amended).
The chimney or flue should be checked annually to ensure clearance of combustion products.
Ventilation in the United Kingdom
This appliance does not normally require purpose-built ventilation but if for any special reason purpose-
built ventilation is provided it should be checked periodically to ensure freedom from obstruction.
Ventilation in the Republic of Ireland
Must be permanent ventilation and must comply with the rules in force and should be checked periodically
to ensure freedom from obstruction.
General Appliance Care
www.charltonandjenrick.co.uk 15 LT5050 (ISS 14)
Any debris from the chimney or flue should be removed from the fuel bed. The fire
should be allowed to cool for three to four hours before removing debris.
Rubbish must not be thrown onto the fuel bed under any circumstances. The cast fire front must be
positioned in front of the fire whilst it is burning.
SECTION FIVE Specification (installation instructions)
NATURAL GAS PROPANE GAS
Category of Appliance: BAS BAS
Category I2H I3P
Gas type: G20 G31
Gas Pressure: 20 mbar 37 mbar
Gas input high: 7.00 kW Gross 7.00 kW Gross
Gas input low: 2.40 kW Gross 2.40 kW Gross
Injector Main: Size 460 Size 135
Battery Remote handset 1.5 V AAA LP3 X2
Appliance 6 x 1.5V AA high power alkaline or 6 x 1.5 V Rechargeable nickel metal hydride with a minimum
capacity of 2200mAh.
Data Label Location: Behind trim
Gas Connection: 8 mm OD Tube
NOTE: The efficiency of this appliance has been measured as specified in BS7977-1 2009 + A1:2013 and the result is 50.9%. The
gross calorific value of the fuel has been used for this efficiency calculation. GASTEC have certified the test data from which it has
been calculated. The efficiency value may be used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating
of dwellings.
16 LT5050 (ISS 14)
SECTION SIX Regulations and Warnings (installation instructions)
• THIS APPLIANCE MUST ONLY BE INSTALLED IN THE GB OR IRELAND.
• Only to be used in sufficiently ventilated room. Read instructions carefully before installation and use. The
appliance must be installed by a competent person, i.e.. Gas Safe Registered Installer in accordance with the
current Gas Safety (Installation and Use) Regulations 1998 (as amended). Failure to do so could lead to
prosecution.
• This PARAGON 2000R is for use ONLY with the GAS STATED ON THE DATA BADGE this may be G20 for Natural Gas
or G31 for Propane Gas CHECK YOU HAVE THE CORRECT APPLIANCE FOR THE GAS YOU ARE USING.
• It can be used in conjunction with the following chimneys: -
• A conventional brick or stone chimney,
• A pre-cast flue conforming to BS 1289 Pt. 1 or Pt. 2
• A metal flue and box conforming to BS 715, further details are covered in later text.
• A non-combustible hearth must be provided to comply with the building regulations or a suitable
proprietary fire surround with a 100 degrees C rating.
• During initial firing an odour may be evident. This is the binder used during the manufacture of the
fibre components and there are no harmful effects produced.
The following are the relevant Codes of Practice and British Standards: -
BS 5871 BS 8303
BS 5440 part 1 BS 1251
BS 6891 BS 6461 parts 1 & 2
BS 715 BS 1289 part 1& 2
Note:- This appliance must be installed to current versions of the above standards and include any
relevant amendments.
The Building Regulations issued by the Department of the Environment
The Building Standards (Scotland) (Consolidation) Regulations issued by the Scottish Development Office.
www.charltonandjenrick.co.uk 17 LT5050 (ISS 14)
SECTION SEVEN Siting the Appliance (installation instructions)
The fire can be installed in the following flues and locations: -
CLASS ONE
A conventional brick or stone chimney as used for a solid fuel appliance with a typical effective cross-
sectional dimension of 225 x 225 mm (9 x 9 ins) or a lined flue with a minimum diameter of 125 mm (5 ins)
Fireplace opening must be 552 mm - 578 mm high by 380 mm – 435 mm wide (or up to 458 mm if the cable
fixing system is used).
The opening depth must be a minimum of 215 mm to allow sufficient volume for debris collection (this
depth may be reduced to 185 mm if the chimney is new or has never been used for solid fuel or oil before).
To obtain this depth it may be necessary to remove the chairbrick.
Note: spacers are available in 20mm and 43mm to further reduce the opening depth if required (if a
spacer is used then the thickness of the spacer must be added to the minimum 300mm hearth depth to
comply with regulations.
Any permanent flue restriction or variable dampers are to be removed or locked fully open. The chimney
should be swept prior to installation if not new.
CLASS TWO PRE-CAST
A pre-cast flue conforming to the requirements of BS 1289 part 1 & 2
A suitable fire resisting fire surround will be required, spaced out to
the correct thickness, between the face of the flue blocks and the rear
of the appliance frame. IMPORTANT: - the flue restrictor plate must
be removed when the appliance is installed in this type of flue.
Note: An inspection should be made to ensure that the internal walls
of the flue are clear of mortar fangs. It is recommended that the
plasterwork should not be directly bonded to the surface of the flue
blocks, ensuring that there is a small air gap between the flue blocks
and the wall surface. The fire can be installed with the plasterwork
being directly bonded to the flue blocks but there is a risk of surface
cracking occurring to the plaster above the appliance.
ALL DIMENSIONS IN mm PRE-CAST FLUE BLOCK
ADDITIONAL DEPTH INCLUDING PLASTER AND FIREPLACE
"A"
300
NONE
SPACER20mm 30mm
94
80
74
60
64
50
"A" "X"
380mm - 435mm
374767320
310
"X" MINIMUM (INCLUDING PLASTER)
0
7
21
43mm
"A"
215 OR 185 MIN. IF FLUE AS NEVER BEENUSED FOR SOLID FUEL
700 MIN.WHEN "A"= 150
680 MIN.
552 MIN.- 578 MAX.
300 MIN.
50 MIN.
ALL DIMENSIONS IN mm
380 MIN.-435 MAX.
18 LT5050 (ISS 14)
CLASS TWO FABRICATED METAL
A double-walled or insulated metal flue box built to the requirements of BS 715 with an insulated flue
having a minimum diameter of 125 mm (5 ins) and a minimum effective overall height of 3 metres (10 ft).
IMPORTANT: - the flue restrictor plate must be removed when the appliance is installed in this
type of flue.
Note: A brick or stone chimney with a 125 mm (5 ins) minimum diameter flue liner conforming to BS 715
may be used. Provided a suitable sealing plate is fitted to the base of the liner and the appliance does not
restrict the opening into the liner.
Dampers or register plates must not restrict any of the above flues. The flue must only service a single
appliance and not have any branches or traps, which may impede the natural draught. If a terminal is fitted
it must be suitable for the purpose.
SECTION EIGHT Fireplace Requirements (installation instructions)
A flat face of 605 mm high x 500 mm wide must be provided around the fireplace opening for the
fixing of the appliance to ensure that a good seal is formed. The base of the fire opening must be
flat to ensure sound fixing of the appliance.
A non-combustible hearth must be provided beneath the appliance within the fireplace opening, a
fire-resisting hearth must also be provided symmetrically disposed about the fireplace opening a
minimum thickness of 12 mm with the perimeter 50mm above floor level. The width must extend
a minimum of 150 mm either side of the fireplace opening and a depth of 300 mm (+ thickness of
spacer if a spacer is used).
Purpose-built superimposed fire-resistant hearths and back panels, specified as suitable by the
manufacturers, may be used, or a suitable proprietary fire surround with a 100oC rating.
Hole in the Wall Installation
Please read these instructions carefully if you intend an Installation without a hearth.
This appliance must be installed in accordance with all relevant sections of approved document “J” of the
building regulations
It is recommended that a non-combustible hearth extends a minimum of 300mm forward of the fire
opening and a minimum of 150mm either side, and that a rise exist at the front edge and sides of the
hearth of a minimum of 50mm.
The fire may be installed so that its base sits on a surface of a fire opening at least 105 mm up from the
floor (this is to ensure that no flame or incandescent material is less than 225mm above the floor, a
requirement of approved document “J”). Where this is the case a means must be provided to support the
www.charltonandjenrick.co.uk 19 LT5050 (ISS 14)
fret this may typically be meet with a small projecting hearth of minimum 100mm.Unless
the fret is fixed to the appliance or is an integral part of the fascia of the appliance.
Consideration should be given to the location of the appliance ensuring it is very visible and it should be
positioned at a height were it can clearly be seen on approach.
Frets, and Fascias used for HOLE in the WALL must be compliant with Paragon Fires CE approval; these are
listed at the end of this page.
Where the fire is fitted as a “Hole in the Wall” without a hearth the installer MUST ensure the appliance is
fixed firmly into the opening to ensure no movement takes place to the fuel bed when the appliance
controls are operated.
The installer MUST ensure that the fuel bed is laid correctly and securely
The installer MUST advise the user that care should be taken when the appliance is in use to ensure
occupants do not get unnecessarily close to the appliance or position furniture or other appliances to close.
The installer MUST remind user of the requirement to fit a “secure fireguard” where the room is used by
elderly, infirm or young persons.
The installer MUST explain to the user that the area immediately in front of the appliance must always be
keep clear of combustible items other than the floor covering (which must be fixed)
In the case of the Pebble fuel bed an alternative layout for “Hole in the Wall” must be followed refer to
page 10 in this Manual, this alternative layout MUST adhered to for ALL HOLE in the WALL installations
20 LT5050 (ISS 14)
CLEARANCE TO SHELF
Minimum clearance from hearth to underside of combustible shelf should be 700mm provided shelf depth 150mm
or less. This height may be reduced to 640mm for a shelf depth of 100mm or less
When the shelf depth is increased by increments of 12.5 mm greater than 150mm, add 25mm to the 700mm
minimum clearance.
CLEARANCE TO SIDES OF FIRE
Minimum width between vertical sides of combustible surround should not be less than 700mm provided fire is
central to surround and sides do not project more than 150 mm. When vertical side forward projection is increased
by 12.5 mm add 50 mm to inside width of surround.
N.B. When fire is fitted this provides a minimum side clearance of 100mm.
Care should be taken to prevent any damage being caused to surrounding soft furnishings or decoration, e.g. many
embossed vinyl wall coverings may become discoloured if placed too close to the appliance.
VENTILATION
In the United Kingdom no special ventilation bricks or vents are required into the room containing the appliance,
provided normal adventitious room ventilation exists. The installer must satisfy this point by carrying out a
mandatory spillage test.
In the Republic of Ireland permanent ventilation must comply with the rules in force
SECTION NINE To Install the Appliance (installation instructions)
EXAMINE FLUE / CHIMNEY
Check that the flue/chimney conforms to the required specifications as previously stated. Examine the condition
and carry out any remedial work. If the flue/chimney has been used for solid fuel or oil, it should be swept prior to
appliance installation. A smoke test must be carried out to check that satisfactory smoke clearance has been
established. If all the smoke is not drawn into the flue, pre-heat the flue with a blowtorch or similar and re-check. If
there is any uncertainty examine for the cause and, if necessary, seek expert advice.
CONNECTING THE GAS SUPPLY
Determine where the gas supply is to be connected to the appliance. This may be done from the front of the unit
from either the left or right side, or a concealed fitting from the rear.
www.charltonandjenrick.co.uk 21 LT5050 (ISS 14)
GAS CONCEALED CONNECTION
If the supply is to be a concealed connection it would be advisable to route 8mm O/D half hard copper tube to the
rear right side of the fireplace opening, taking into account the requirements of BS 6891 1988 dealing with enclosed
pipes. Form the tube so that it enters the fire via the blind grommet at the rear of the appliance. A 8mm restrictor
elbow can be positioned under the burner assembly on the right-hand side connected to the gas supply pipe and its
outlet connected to the gas appliance.
Note: pipework in the opening of the fireplace to the rear of the appliance must be suitably wrapped in accordance
with the regulations.
GAS CONNECTION FROM THE FRONT
Connections may be made from the front of the appliance from either the left or right in 8-mm diameter pipe. If a
left-hand connection is required the tube should be routed behind the bezel plate under the gas control tap and
onto the inlet elbow. The inlet elbows should be rotated to the required position. A suitable isolating cock should
always be fitted in the supply feed to the fire to facilitate servicing.
FIXING FIRE INTO OPENING
Remove the paper backing from the length of foam seal and stick it around the rear flange of fire. If a spacer is going
to be used stick the second length (supplied with the spacer kit) around the rear face of the spacer unit, THE FOAM
SEAL MUST BE POSITIONED TO ENSURE AN AIR TIGHT SEAL WHEN THE APPLIANCE IS FITTED.
NOTE: -DO NOT USE PERAMENT SEALING COMPONDS i.e. SILICON SEALANT. THIS COULD CAUSE THE APPLIANCE
TO BE DAMAGED WHEN IT IS REMOVED FOR SERVICING, AND COULD INVALIDATE THE WARRENTY.
If the spacer is not being used, mark position of flange hole in the fireplace front drill and fix firebox in position with
wall plugs and wood screws. If spacer is being used fix the spacer to the fireplace first with wood screws and wall
plugs then screw firebox to spacer box using screws provided.
OPTIONAL CABLE FIXING SYSTEM (Available on request from PARAGON FIRES)
(for use when fixing to 18" openings or when it is
desirable not to drill the fireplace fascia) it may not be
possible to use the cable fixing system with some pre-
cast flues.
Drill 4 holes in the rear of the fireplace opening in the
position shown and fix securely the 4 eye bolt
provided with suitable wall plugs
260mmCRS.
30mm
460mm
FIX 4 OFF EYEBOLTS INPOSITIONS SHOWN
22 LT5050 (ISS 14)
Fix the fire casing back into the opening
using the cable fixing system as shown in
do not cut off loose ends of cable after
fixing, coil and tuck carefully behind sides
of Refractory back
Note: when using the cable fixing kit with the spacer,
fix and seal the spacer to the rear of the appliance
flange with the screws and foam seal provided.
CHECKING GAS SOUNDNESS
*Batteries must be connected before proceeding with any soundness testing*
After completing the gas connection to the appliance, check for gas soundness in accordance with current codes of
practice.
FUEL BED LAYOUT
Important: - Refer to the Health & Safety Notice located on page 5 of this booklet before cleaning or replacing
any refractory material.
Lay fuel bed as shown in the Users Section of these instructions.
ENSURE THE FUEL BED IS PLACED AS INDICATED IN THESE INSTRUCTIONS.
Positioning Remote Control Eye
Note: - The remote control eye is fixed to the front of the control facia using a self adhesive clip.
In some instances (e.g. when an alternative fret or ash pan cover is used) it may be necessary to reposition the
remote control eye, an alternative position is specified below.
• Position the remote control eye as shown with the front
edge level with the ash pan cover.
• Secure in position with insulation tape as shown. Position
the tape at the rear of the eye do not place any tape over
the eye as this may cause receiving problems.
• Connect battery holder to appliance and insert batteries.
• Reposition ash pan cover.
• Fit 1.5V AAA LP3 X2 (supplied) to remote hand set (see
Section 2).
• Check that a signal is being received by pointing the
remote control hand set in the direction of the appliance
and simultaneously press the buttons marked ‘ ’ and ‘standby’. Continue to hold in these two buttons until a
‘bleep’ is heard (approximately 2-3 sec.). If no sound is hear check position of remote control eye.
TENSIONING NUT
CLAMP SCREW
www.charltonandjenrick.co.uk 23 LT5050 (ISS 14)
CHECKING OPERATION OF FIRE
• Remove ash pan cover.
• Remove the screw from the pressure test point on the inlet elbow and fit pressure gauge.
• Turn on the gas to the appliance.
• Purge the air from the appliance by operating the appliance (see Section 2). The appliance will spark for
approximately 20 second at which point if no ignition is detected the appliance will go to lock out and you
must repeat the ignition procedure.
• Check that the electrode is sparking at the gap between the thermocouple tip and the electrode and that the
pilot ignition is established. After approximately 20 seconds the main burner will light on the high setting.
• Check the inlet pressure is 20 + 1 mbar for Natural Gas (G20) and at 37 ±1 mbar for Propane (G31).
• Refit pressure test point screw and check for leaks.
• Refit ash pan cover.
CHECKING PRODUCT CLEARANCE
Check for satisfactory clearance of combustion products. Close all doors and windows and leave fire burning for 5
minutes. Then position a smoke match just into the top of the fire opening and move it left and right, all the smoke
must be drawn into the flue. If spillage occurs, allow a further 5 minutes. Should spillage still occur, remove
appliance restrictor plate if still fitted and repeat spillage test. If spillage still occurs turn off the fire and seek expert
advice.
If an extractor fan is situated in the room this test should be repeated with the fan running. If there is a connected
room with an extractor fan, the test should be repeated with all the doors to that room opened and the extractor
fan running.
COMPLETION OF INSTALLATION
Fit the decorative trim with the four magnetic strips placed two on each vertical side flange of the firebox - one at
the top and one at the bottom. Offer the decorative trim up squarely and centrally and push back into position.
Position a suitable fire fret up to the front of the appliance ensuring that it meets the specification referred to
earlier.
Demonstrate the lighting and extinguishing procedures to the user and the removal and refitting of the decorative
trim and fret for cleaning.
ADVISE CUSTOMER THAT:
• This appliance has a naked flame, as with all such fires it is recommended that a fireguard should be used for
the protection of children, the elderly and infirm. Fireguards should conform to BS 6539 (1984) (Fireguards
for use with solid fuel appliances).
• The curing effect of heating the fuel bed and other Refractory components will cause an initial odour. This is
due to the starch used in the manufacturing process and is non-toxic.
• Any debris should be cleaned from the appliance. A vacuum cleaner can be used but only after all the loose
components have been removed. The appliance should be serviced annually by a competent person in
accordance with these instructions and the appliance checked for spillage in accordance with the method
detailed in these instructions.
Hand these instructions over to the user.
24 LT5050 (ISS 14)
SECTION TEN Maintenance Instructions (maintenance instructions)
Important: - Refer to the Health & Safety Notice located on page 5 of this booklet before cleaning or
replacing any refractory material.
• Servicing should be carried out annually by a competent person such as a Gas Safe-registered person in
accordance with the relevant regulations, to ensure the safe and correct operation of the appliance.
• Before commencing any service or replacement of parts, turn off the main gas supply and disconnect
transformer from power supply. After servicing check for gas soundness.
• When ordering spare parts please quote appliance name and serial number, these can be found on the data
badge, which is located on the flange behind the decorative fire trim.
• At least once a year, check for debris in the catchment area behind the fire and in the flue way.
• If soot has accumulated check to establish cause, rectify and clean flue or chimney accordingly.
• Examine the fuel bed components for signs of cracking and replace if necessary. (IMPORTANT) The loose
fuel bed components should only be replaced as a complete set with no extra components added.
FUEL BED CLEANING
Important: - Refer to the Health & Safety Notice located on page 5 of this booklet before cleaning or
replacing any refractory material.
The loose fuel bed components are delicate and they should be handled with great care. They may be removed for
cleaning. They can be brushed very gently with a soft brush to remove dust or any deposits. A vacuum cleaner may
only be used after the loose components have been removed.
REPLACEMENT OF GAS CONTROL
1. Turn off the gas supply by the isolating cock.
2. Remove fire fret.
3. Remove all loose fuel bed components.
4. Disconnect battery leads and remove appliance battery pack. Detach remote control eye from hearth. (See
Section Seven when repositioning.)
5. Remove 2 screws fixing burner unit into the casing.
6. Disconnect fire at inlet elbow and remove burner unit from the casing.
7. Disconnect the thermocouple from the rear of the gas valve.
8. Undo the three compression nuts securing the pipes to the gas valve and remove the two screws fixing the
valve to the bracket.
9. Clean, service or replace gas valve.
10. Re-assemble in the reverse order.
11. Turn on the gas supply, check for soundness and recommission appliance.
www.charltonandjenrick.co.uk 25 LT5050 (ISS 14)
REPLACEMENT OF INJECTOR
1. Repeat operations 1-7 for removal of gas control.
2. Undo the two screws retaining the silencer bracket.
3. Lift away the silencer; noting its position the cut out slot pointing down, it must be put back in exactly the
same orientation.
4. Unscrew the locking nut fixing injector to mounting bracket and silencer retaining bracket clean or replace as
necessary.
5. Re-assemble the in reverse order and check assembly for gas soundness.
6. Turn on gas supply, check for gas soundness and recommission appliance.
Replacement of Oxy-Pilot Assembly
NOTE: If the pilot assembly is replaced it must be replaced by an identical unit from the same manufacturer and
replaced as a complete unit it is a NON SERVICABLE ITEM.
1. Repeat operations 1-4 for removal of gas control.
1. Disconnect the pipe from the gas control to the pilot burner
2. Disconnect the thermocouple connection from the rear of the gas control.
3. Remove ignition lead from pilot assembly.
4. Remove the two screws securing the oxy-pilot to the burner.
5. Before replacing ensure the code number for Oxy-Pilot replacement is suitable.
6. Re-assemble the in reverse order and check assembly for gas soundness.
7. Turn on the gas supply, check for gas soundness and recommission appliance
REPLACEMENT OF CONTROL UNIT (EDB)
2. Repeat operations 1-7 for removal of gas control.
3. Disconnect leads from control unit and remove 4 bolts.
4. Re-assemble in the reverse order.
5. Turn on the gas supply, check for gas soundness and recommission appliance.
26 LT5050 (ISS 14)
SECTION NINE Wiring Diagram (maintenance instructions)
Attach to
the valve
www.charltonandjenrick.co.uk 27 LT5050 (ISS 14)
28 LT5050 (ISS 14)
www.charltonandjenrick.co.uk 29 LT5050 (ISS 14)
Register your appliance online today to active your warranty
30 LT5050 (ISS 14)
GAS FIRE COMMISSIONING CHECKLIST This Commissioning Checklist is to be completed in full by the competent person who commissioned the gas fire as a means of demonstrating compliance with the appropriate Building Regulations and then handed to the customer to keep for future reference.
Failure to install and commission according to the manufacturer’s instructions and complete this Benchmark Commissioning Checklist will
invalidate the warranty. This does not affect the customer’s statutory rights.
*All installations in England and Wales must be notified to be Local Authority Building Control (LABC) either directly or through a
Competent Persons Scheme. A Building Regulations Compliance Certificate will then be issued to the customer.
Site Requirements Yes N/A
Was the chimney checked to ensure it only serves one flue/fire, has no obstructions and is continuous?
Has any debris at the base of the chimney been removed? For brick chimney installations is there enough depth for 12 litres of debris, or precast flues 2 litres of debris? (see instructions for debris gap details)
Have damper and register plates been removed or locked in the fully open position ensuring correct size of flue is maintained?
If previously used for solid fuel has the chimney been thoroughly swept? If the chimney is pre-cast has the inside of the flue been checked for extruded cement / sealant which must be removed?
Has the fire place been checked for under-floor air supply which must be sealed off? Has the chimney been inspected prior to fitting the gas fire to ensure that it is in good condition?
Has the structure of the chimney been checked for leakage using a smoke pellet test? (See BS5440-1 for details).
Ventilation
Does the installation require any additional ventilation requirements as detailed in the manufacturer’s instructions?
Hearth Requirements- where fitted
Is the hearth constructed from non -combustible material?
Is the hearth a minimum of 12mm thick with a minimum floor to top surface of 50mm?(BS5871) or as per manufacturer’s instructions?
Is the hearth for open fronted fires a minimum of 760mm wide and has 300mm projecting from the fire opening (BS6871) or to manufacturer’s instructions?
Mounting height (where applicable) has the fire been installed to the correct mounting height- as per manufacturer’s instructions?
Firebox and Fuel Bed
Has the fuel bed, coals, pebbles etc. been fitted to manufacturer’s instructions?
Gas Supply
Has an isolation tap/restrictor inlet elbow been fitted for servicing?
Has the gas supply been thoroughly purged prior to connection to remove any debris?
Has a gas tightness test been completed prior to breaking into the gas supply and following completion of installation?(IGEM/UP/1B)
Record burner gas pressure reading? If only the supply pressure is available a gas rate must be undertaken.(GSIUR REG26/9C)
Record dynamic inlet gas pressure (working pressure) reading (all gas appliances running)
Spillage test
Installation passes smoke match test with any extractor fans turned on (see manufacturer’s instructions)
Installation
Has the gas fire been installed and commissioned in accordance with manufacturer’s instructions?
Has the fire been installed with the correct clearance to combustible materials, as per manufacturer’s instructions?
The operation of the appliance and controls have been demonstrated to the customer including battery replacement where applicable?
The manufacturer’s literature, including Benchmark Checklist and Service record has been explained and left with the customer?
Has the appliance been registered with the Local Authority as detailed on the Gas Safe web site and is a legal requirement and forms part of the warranty?
Customer’s Signature: Commissioning Engineer’s Signature:
(To confirm satisfactory demonstration and receipt of manufacturer’s literature)
www.charltonandjenrick.co.uk 31 LT5050 (ISS 14)
SERVICE RECORD
It is essential that your gas fire is serviced regularly and that the appropriate Service Interval Record is
completed. Service Provider
Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s
instructions. Always use the manufacturer’s specified spare part when replacing controls.
SERVICE 01 Date:
Engineer name:
Company name:
Telephone No:
Gas safe register No:
Comments:
Signature
SERVICE 02 Date:
Engineer name:
Company name:
Telephone No:
Gas safe register No:
Comments:
Signature
SERVICE 03 Date:
Engineer name:
Company name:
Telephone No:
Gas safe register No:
Comments:
Signature
SERVICE 04 Date:
Engineer name:
Company name:
Telephone No:
Gas safe register No:
Comments:
Signature
SERVICE 05 Date:
Engineer name:
Company name:
Telephone No:
Gas safe register No:
Comments:
Signature
32 LT5050 (ISS 14)
Product
ID Label
A-0030/A-
0318 Serial No
Prefix
JJ
NG
A-0032 JK LP
Fire Box Labels: Restrictor Plate
Spillage (Text)
Data Badge
Fire Box Grommet
Burner Tray / Box Assembly
Warning Label (Fire Guard)
Cable Clips(Alum x 1) (Plastic x 1)
Ceramics Set (Part no 5568)
Fixing Kit (0705) eye bolt foam strip screw magnets wall plug
Qty 4 Qty 1 Qty 4 Qty 4 Qty 4
Restrictor Elbow (male) (Part No 2613)
Battery AAA 1.5V LR3 X2
Remote Control (Hand Set)
Battery Holder
Battery Insulation Blanket
AA Battery (12)
Owners Book
ID Label & Packing Labels
Serial Number
Inspector