Low voltage cables
-
Upload
stephanie-sanchez -
Category
Documents
-
view
233 -
download
1
description
Transcript of Low voltage cables
77
Description
Soft copper conductor, XLPE insulated.
Construction
ConductorCompressed Stranded Soft copper.
InsulationCross Linked Polyethylene (XLPE 90°C).
OptionsAluminum Conductor, XLPE SR (Sunlight resistant) insulation.For sizes greater than 1/0 AWG, Type Tray Cable (TC).
Characteristics
Operating temperatureDry Locations: 90°CWet Locations: 90°C
Operating Voltage600 V.
Uses and Applications
Overhead distribution of electric energy in low voltage systems. Connectionto boards, motors, and building wiring.
Installation ducts and raceways. Abrasion and moisture resistant insulation,its dimensions permits optimal filled in tubes and ducts. Pass VW-1 Verticalflame Test.
XHHW-2 CablesCross (X) Linked Polyethylene Insulation, High Heat resistant (90°C),2: Suitable for Dry and Wet Locations
8
Standards and Specifications
CENTELSA XHHW-2 cables are manufacturing according to thefollowing standards:
ASTM B3, NTC-ICONTEC 359. Soft copper wire.ASTM B8, NTC-ICONTEC 307. Concentric Lay Stranded copperconductors.ASTM B787. 19 Wire Combination Unilay Stranded Copper conductorsfor subsequent insulationUL 1581, NTC-3203. Reference Standard for Electrical Wires, Cablesand Flexible Cords.UL 44, NTC-3277. Thermo set-Insulated Wires and Cables.
Certifications
CENTELSA XHHW-2 Cables type, are certified by:UL 44 File E137698.
Note: Other configurations and sizes not specified herein are availableupon request.
9
Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. 90°C conductor temperature, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
Cables Type XHHW-2 600V (International Unit System)Cross (X) Linked Polyethylene Insulation, High Heat resistant (90°C), 2: Suitable for Dry and Wet Locations
Manufacturing Standards: UL 44, NTC-3277. Thermo set-Insulated Wires and Cables.
3.393.854.455.976.908.099.58
11.1012.1013.2314.5015.9217.6218.9620.2221.3823.4826.1827.9328.7729.5731.1232.56
2.083.315.268.37
13.3021.1533.6342.4153.4867.4385.03107.2126.7152.0177.3202.7253.4304.0354.7380.0405.4456.0506.7
BBBBBBBBBBBBBBBBBBBBBBB
1.792.252.853.594.525.717.208.189.18
10.3111.5813.0014.1815.5216.7817.9420.0422.0023.7524.5925.3926.9428.38
0.760.760.761.141.141.141.141.401.401.401.401.401.651.651.651.651.652.032.032.032.032.032.03
8.455.313.342.101.32
0.8310.5230.4150.3290.2610.2070.1640.1390.116
0.09920.08680.06940.05780.04960.04630.04340.03860.0347
26395896
146223344435541674841
105112481487172519632437293934123649388643584830
35405580
105140190220260300350405455505570615700780855885920985
1055
253040557595
130150170195225260290320350380430475520535555585615
141210
86421
1/02/03/04/0
250300350400500600700750800900
1000
7777777
19191919193737373737616161616161
SIZEAWG / kcmil
CONDUCTORDIAMETER
(mm)
INSULATIONTHICKNESS
(mm)
APPROX.TOTAL
WEIGHT(kg/km)
DC RESISTANTAT 20°C¹(ohm/km)
AMPACITY²(A)3
AMPACITY²(A)4
DIAMETEROVER
INSULATION(mm)
CROSSSECTION
(mm2)
STRANDSNo.
STRANDINGCLASS
10
Cables Type XHHW-2 600VCross (X) Linked Polyethylene Insulation, High Heat resistant (90°C), 2: Suitable for Dry and Wet Locations
Manufacturing Standards: UL 44, NTC-3277. Thermo set-Insulated Wires and Cables.
133152175235272318377437476521571627694747796842924
103111001133116412251282
0.003230.005130.00815
0.01300.02060.03280.05210.06570.0829
0.1050.1320.1660.1960.2360.2750.3140.3930.4710.5500.5890.6280.7070.785
BBBBBBBBBBBBBBBBBBBBBBB
7089
112141178225283322361406456512558611661706789866935968
100010611117
3030304545454555555555556565656565808080808080
2.581.621.02
0.6410.4030.2530.1590.1260.100
0.07950.06300.05000.04230.03530.03020.02640.02120.01760.01510.01410.01320.01180.0106
1826396598
150231292364453565707838999
115913191638197522932452261129293246
35405580
105140190220260300350405455505570615700780855885920985
1055
253040557595
130150170195225260290320350380430475520535555585615
141210
86421
1/02/03/04/0
250300350400500600700750800900
1000
7777777
19191919193737373737616161616161
Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. 90°C conductor temperature, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
SIZEAWG / kcmil
CONDUCTORDIAMETER
(mils)
INSULATIONTHICKNESS
(mils)
APPROX.TOTAL
WEIGHT(pound/1000ft)
DC RESISTANTAT 20°C¹
(ohm/1000ft)
AMPACITY²(A)3
AMPACITY²(A)4
DIAMETEROVER
INSULATION(mils)
CROSSSECTION(sq inches)
STRANDSNo.
STRANDING(mils)
11
Rubber or Thermoset Insulation, High Heat Resistant (90°C) for Dry LocationsRubber or Thermoset Insulation, Heat Resistant (90°C), 2: Suitable for Dry and Wet LocationsUnderground Service Entrance Thermoset Insulation, Heat Resistant (90°C), 2: Suitable for Dry and Wet Locations
Description
Soft copper conductor, XLPE insulated.
Construction
ConductorCompressed Stranded Soft copper.
InsulationCross Linked Polyethylene (XLPE 90°C).Options
Aluminum Conductor, XLPE SR (Sunlight resistant) insulation.For sizes greater than 1/0 AWG, Type Tray Cable (TC).
Characteristics
Operating temperatureDry locations, RHH, RHW-2 and USE-2 90°•'3fC.Wet locations, RHW-2 and USE-2 90°•'3fC.Wet locations, RHH 75°C.
Operating Voltage600 V, RHH, RHW-2 and USE-2.2000 V, RHH y RHW-2.
RHH/RHW2/USE-2 Cables
12
Uses and Applications
General purpose for power and control circuits, industrial and buildingwiring. When used as USE-2 conductor, can be installed in undergroundservice entrance and in directed buried. Abrasion and moisture resistantinsulation, its dimensions permits optimal filled in tubes and ducts.Pass VW-1 Vertical flame Test.
Standards and Specifications
ASTM B3, NTC-ICONTEC 359. Soft copper wire.ASTM B8, NTC-ICONTEC 307. Concentric Lay Stranded copperconductors.ASTM B787. 19 Wire Combination Unilay Stranded Copper conductorsfor subsequent insulationUL 1581, NTC-3203. Reference Standard for Electrical Wires, Cablesand Flexible Cords.UL 44, NTC-3277. Thermo set-Insulated Wires and Cables.
Certifications
CENTELSA RHH / RHW-2 / USE-2 Cables type, are certified by:UL 44 File E137698, for RHH y RHW-2.UL 854 File E207803, for USE-2.
Note: Other configurations and sizes not specified herein are availableupon request.
13
Cables Type RHH / RHW-2 / USE-2 600V (Internacional Unit System)Rubber or Thermoset Insulation, High Heat Resistant (90°C) for Dry LocationsRubber or Thermoset Insulation, Heat Resistant (90°C), 2: Suitable for Dry and Wet LocationsUnderground Service Entrance Thermoset Insulation, Heat Resistant (90°C), 2: Suitable for Dry and Wet Locations
Manufacturing Standard: UL 44, NTC-3277. Thermo set-Insulated Wires and Cables. UL 854, NTC-4564 Service entrance Cables (For USE-2)
Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. 90°C conductor temperature, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
4.174.635.236.757.688.87
10.3612.3613.3614.4915.7617.1819.1420.4821.7422.9025.0027.7429.4930.3331.1332.6834.12
2.083.315.268.37
13.3021.1533.6342.4153.4867.4385.03107.2126.7152.0177.3202.7253.4304.0354.7380.0405.4456.0506.7
BBBBBBBBBBBBBBBBBBBBBBB
1.792.252.853.594.525.717.208.189.18
10.3111.5813.0014.1815.5216.7817.9420.0422.0023.7524.5925.3926.9428.38
1.141.141.141.521.521.521.522.032.032.032.032.032.412.412.412.412.412.792.792.792.792.792.79
8.455.313.342.101.32
0.8310.5230.4150.3290.2610.2070.1640.1390.116
0.09920.08680.06940.05780.04960.04630.04340.03860.0347
314465
105155234357460568704873
108612951537177920192499300934883727396544424917
35405580
105140190220260300350405455505570615700780855885920985
1055
253040557595
130150170195225260290320350380430475520535555585615
141210
86421
1/02/03/04/0
250300350400500600700750800900
1000
7777777
19191919193737373737616161616161
SIZEAWG / kcmil
CROSSSECTION
(mm²)
CONDUCTORDIAMETER
(mm)
DIAMETEROVER
INSULATION(mm)
DC RESISTANCEAT 20°C 1(ohm/km)
AMPACITY²(A)3
AMPACITY²(A)4
INSULATIONTHICKNESS
(mm)
STRANDSNo.
STRANDINGCLASS
APPROX.TOTAL
WEIGHT(kg/km)
14
Cables Type RHH / RHW-2 / USE-2 600VRubber or Thermoset Insulation, High Heat Resistant (90°C) for Dry LocationsRubber or Thermoset Insulation, Heat Resistant (90°C), 2: Suitable for Dry and Wet LocationsUnderground Service Entrance Thermoset Insulation, Heat Resistant (90°C), 2: Suitable for Dry and Wet Locations
Manufacturing Standard: UL 44, NTC-3277. Thermo set-Insulated Wires and Cables. UL 854, NTC-4564 Service entrance Cables (For USE-2).
164182206266303349408487526571620676753806856901984
109211611194122612871343
0.003230.005130.00815
0.01300.02060.03280.05210.06570.0829
0.1050.1320.1660.1960.2360.2750.3140.3930.4710.5500.5890.6280.7070.785
BBBBBBBBBBBBBBBBBBBBBBB
7089
112141178225283322361406456512558611661706789866935968
100010611117
4545456060606080808080809595959595
110110110110110110
2.581.621.02
0.6410.4030.2530.1590.1260.100
0.07950.06300.05000.04230.03530.03020.02640.02120.01760.01510.01410.01320.01180.0106
21304470
104157240309382473587730870
1033119513571680202223442504266529853305
35405580
105140190220260300350405455505570615700780855885920985
1055
253040557595
130150170195225260290320350380430475520535555585615
141210
86421
1/02/03/04/0
250300350400500600700750800900
1000
7777777
19191919193737373737616161616161
SIZEAWG / kcmil
CROSSSECTION(sq inches)
CONDUCTORDIAMETER
(mils)
DIAMETEROVER
INSULATION(mils)
DC RESISTANCEAT 20°C 1
(ohm/1000ft)
AMPACITY²(A)3
AMPACITY²(A)4
INSULATIONTHICKNESS
(mils)
STRANDSNo.
STRANDINGCLASS(mils)
APPROX.TOTAL
WEIGHT(pounds/1000ft)
Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. 90°C conductor temperature, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.
6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
15
Cables Type RHH / RHW-2 / USE-2 2000V (Internacional Unit System)Rubber or Thermoset Insulation, High Heat Resistant (90°C) for Dry Locations.Rubber or Thermoset Insulation, Heat Resistant (90°C), 2: Suitable for Dry and Wet Locations.
Manufacturing Standard: UL 44, NTC-3277. Thermo set-Insulated Wires and Cables.
Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. T90°C conductor temperature, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
4.955.416.017.298.229.41
10.9012.9013.9015.0316.3017.7219.6821.0222.2823.4425.5428.2830.0330.8731.6733.2234.66
2.083.315.268.37
13.3021.1533.6342.4153.4867.4385.03107.2126.7152.0177.3202.7253.4304.0354.7380.0405.4456.0506.7
BBBBBBBBBBBBBBBBBBBBBBB
1.792.252.853.594.525.717.208.189.18
10.3111.5813.0014.1815.5216.7817.9420.0422.0023.7524.5925.3926.9428.38
1.521.521.521.781.781.781.782.292.292.292.292.292.672.672.672.672.673.053.053.053.053.053.05
8.455.313.342.101.32
0.8310.5230.4150.3290.2610.2070.1640.1390.116
0.09920.08680.06940.05780.04960.04630.04340.03860.0347
375172
111163242367471580717888
110213121556179920402522303535153754399444724948
35405580
105140190220260300350405455505570615700780855885920985
1055
253040557595
130150170195225260290320350380430475520535555585615
141210
86421
1/02/03/04/0
250300350400500600700750800900
1000
7777777
19191919193737373737616161616161
SIZEAWG / kcmil
CROSSSECTION
(mm²)
CONDUCTORDIAMETER
(mm)
DIAMETEROVER
INSULATION(mm)
DC RESISTANCEAT 20°C 1(ohm/km)
AMPACITY²(A)3
AMPACITY²(A)4
INSULATIONTHICKNESS
(mm)
STRANDSNo.
STRANDINGCLASS
APPROX.TOTAL
WEIGHT(kg/km)
16
Cables Type RHH / RHW-2 / USE-2 2000VRubber or Thermoset Insulation, High Heat Resistant (90°C) for Dry Locations.Rubber or Thermoset Insulation, Heat Resistant (90°C), 2: Suitable for Dry and Wet Locations.
Manufacturing Standard: UL 44, NTC-3277. Thermo set-Insulated Wires and Cables.
195213236287324370429508547592642698775828877923
1006111311821215124713081365
0.003230.005130.00815
0.01300.02060.03280.05210.06570.0829
0.1050.1320.1660.1960.2360.2750.3140.3930.4710.5500.5890.6280.7070.785
BBBBBBBBBBBBBBBBBBBBBBB
7089
112141178225283322361406456512558611661706789866935968
100010611117
606060707070709090909090
105105105105105120120120120120120
2.581.621.02
0.6410.4030.2530.1590.1260.100
0.07950.06300.05000.04230.03530.03020.02640.02120.01760.01510.01410.01320.01180.0106
25344875
109163247317390482597741882
1046120913711695203923622523268430053326
35405580
105140190220260300350405455505570615700780855885920985
1055
253040557595
130150170195225260290320350380430475520535555585615
141210
86421
1/02/03/04/0
250300350400500600700750800900
1000
7777777
19191919193737373737616161616161
Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. T90°C conductor temperature, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
SIZEAWG / kcmil
CROSSSECTION
(mils)
CONDUCTORDIAMETER
(mils)
DIAMETEROVER
INSULATION(mils)
DC RESISTANCEAT 20°C 1
(ohm/1000ft)
AMPACITY²(A)3
AMPACITY²(A)4
INSULATIONTHICKNESS
(mils)
STRANDSNo.
STRANDINGCLASS
APPROX.TOTAL
WEIGHT(pound/1000ft)
17
Description
Soft copper conductor, XLPE or PE insulated and an PVC external jacket.
Construction
ConductorCompressed Stranded Soft copper.
InsulationThermoplastic Polyethylene (PE 75°•'3fC), for PE-PVC.Cross Linked Polyethylene (XLPE 90°•'3fC), for XLPE-PVC.
OptionsAluminum Conductor, PVC-LS (Low smoke emissions) jacket and PVC SR(Sunlight resistant) jacketFor sizes greater than 1/0 AWG, Type Tray Cable (TC).
Characteristics
Operating temperatureDry and wet locations.75°C for TTU PE-PVC.90°C for TTU XLPE-PVC.
Operating Voltage600 V and 2000 V
Uses and Applications
Industrial installations, distribution and lighting systems. Dry or wet locationsinstallations, in Tray Cable, ducts or raceways. Sizes 8 AWG and greater areuseful for directed burial.
TTU CablesThermoplastic (or Thermoset) Insulation, Thermoplastic Jacket. Underground
18
TTU design join excellent PE electrical properties, electrical andmechanical XLPE properties as insulation with mechanical and flameretardancy PVC properties as external jacket.
Standards and Specifications
CENTELSA TTU Cables are manufactured under the followingstandards:
ASTM B3, NTC-ICONTEC 359. Soft copper wire.ASTM B8, NTC-ICONTEC 307. Concentric Lay Stranded copperconductors.ASTM B787. 19 Wire Combination Unilay Stranded Copper conductorsfor subsequent insulation.UL 1581, NTC-3203. Reference Standard for Electrical Wires, Cablesand Flexible Cords.ICEA S-95-658, NTC-ICONTEC 1099-1. Power Cables rated 2000volts or less for the Distribution of Electrical Energy.
Certifications
CENTELSA TTU cables are certified by CIDET (Colombia). Cert. No.408.
Note: Other configurations and sizes not specified herein are availableupon request.
19
Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. 75°C for PE insulation, 90°C conductor temperature nfor XLPE insulation, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
Cables Type TTU 600V (International Unit System)Thermoplastic (or Thermoset) Insulation, Thermoplastic Jacket. Underground
Manufacturing Standard: ICEA S-95-658, NTC-ICONTEC 1099-1. Power Cables rated 2000 volts or less for the Distribution of Electrical Energy.
DIAMETEROVER
JACKET(mm)
SIZEAWG /kcmil
DIAMETEROVER
INSULATION(mm)
JACKETTHICKNESS
(mm)
APPROX.TOTAL
WEIGHT(kg/km)
DCRESISTANCE
AT 20°C1
(ohm/km)
STRANDINGCLASS
XLPE INSULATIONPE INSULATION
CROSSSECTION
(mm2)
CONDUCTORDIAMETER
(mm)
INSULATIONTHICKNESS
(mm)
AMPACITY 2
(A)4AMPACITY 2
(A)3AMPACITY 2
(A)4AMPACITY 2
(A)3STRANDS
No.
3.383.854.445.966.898.089.57
11.0912.0913.2214.4915.9117.6118.9520.2121.3723.4726.1827.9328.7729.5731.1232.56
2.083.315.268.37
13.3021.1533.6342.4153.4867.4385.03107.2126.7152.0177.3202.7253.4304.0354.7380.0405.4456.0506.7
BBBBBBBBBBBBBBBBBBBBBBB
1.792.252.853.594.525.717.208.189.18
10.3111.5813.0014.1815.5216.7817.9420.0422.0023.7524.5925.3926.9428.38
0.760.760.761.141.141.141.141.401.401.401.401.401.651.651.651.651.652.032.032.032.032.032.03
202535506585
115130150175200230255285310335380420460475490520545
3035507095
125170195230265310360405455505545620690755785815870935
253040557595
130150170195225260290320350380430475520535555585615
8.455.313.342.101.32
0.8310.5230.4150.3290.2610.2070.1640.1390.116
0.09920.08680.06940.05780.04960.04630.04340.03860.0347
35405580
105140190220260300350405455505570615700780855885920985
1055
0.380.380.380.380.760.760.761.141.141.141.141.141.141.651.651.651.651.651.651.651.651.651.65
141210
86421
1/02/03/04/0
250300350400500600700750800900
1000
7777777
19191919193737373737616161616161
4.224.695.286.808.499.67
11.1713.4614.4615.5916.8618.2819.9822.3923.6424.8026.9029.6131.3632.2033.0034.5636.00
324666
106170251376494605743916
113213351632187921252614313036163858410045835064
20
Cables Type TTU 600VThermoplastic (or Thermoset) Insulation, Thermoplastic Jacket. Underground
Manufacturing Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.Power Cables rated 2000 volts or less for the Distribution of Electrical Energy.
133152175235271318377437476521571626693746796841924
103111001133116412251282
0.003230.005130.00815
0.01300.02060.03280.05210.06570.0829
0.1050.1320.1660.1960.2360.2750.3140.3930.4710.5500.5890.6280.7070.785
BBBBBBBBBBBBBBBBBBBBBBB
7089
112141178225283322361406456512558611661706789866935968
100010611117
3030304545454555555555556565656565808080808080
202535506585
115130150175200230255285310335380420460475490520545
3035507095
125170195230265310360405455505545620690755785815870935
253040557595
130150170195225260290320350380430475520535555585615
2.581.621.02
0.6410.4030.2530.1590.1260.100
0.07950.06300.05000.04230.03530.03020.02640.02120.01760.01510.01410.01320.01180.0106
35405580
105140190220260300350405455505570615700780855885920985
1055
1515151530303045454545454565656565656565656565
141210
86421
1/02/03/04/0
250300350400500600700750800900
1000
7777777
19191919193737373737616161616161
166185208268334381440530569614664720787881931976
1059116612351268129913601417
22314471
114168253332406499615761897
1097126314281756210424302593275530803403
DIAMETEROVER
JACKET(mils)
SIZEAWG /kcmil
DIAMETEROVER
INSULATION(mils)
JACKETTHICKNESS
(mils)
APPROX.TOTAL
WEIGHT(pounds/1000ft)
DCRESISTANCE
AT 20°C1
(ohm/1000ft)
STRANDINGCLASS
XLPE INSULATIONPE INSULATION
CROSSSECTION(sq inches)
CONDUCTORDIAMETER
(mils)
INSULATIONTHICKNESS
(mils)
AMPACITY 2
(A)4AMPACITY 2
(A)3AMPACITY 2
(A)4AMPACITY 2
(A)3STRANDS
No.
Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. 75°C for PE insulation, 90°C conductor temperature nfor XLPE insulation, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
21
Cables Type TTU 600V (International Unit System)Thermoplastic (or Thermoset) Insulation, Thermoplastic Jacket. Underground
Manufacturing Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.Power Cables rated 2000 volts or less for the Distribution of Electrical Energy.
4.164.635.226.507.448.62
10.1111.6112.6113.7415.0116.4318.1319.4720.7321.8924.7626.7128.4729.3130.1131.6633.10
2.083.315.268.37
13.3021.1533.6342.4153.4867.4385.03107.2126.7152.0177.3202.7253.4304.0354.7380.0405.4456.0506.7
BBBBBBBBBBBBBBBBBBBBBBB
1.792.252.853.594.525.717.208.189.18
10.3111.5813.0014.1815.5216.7817.9420.0422.0023.7524.5925.3926.9428.38
1.141.141.141.401.401.401.401.651.651.651.651.651.901.901.901.902.292.292.292.292.292.292.29
202535506585
115130150175200230255285310335380420460475490520545
3035507095
125170195230265310360405455505545620690755785815870935
253040557595
130150170195225260290320350380430475520535555585615
8.455.313.342.101.32
0.8310.5230.4150.3290.2610.2070.1640.1390.116
0.09920.08680.06940.05780.04960.04630.04340.03860.0347
35405580
105140190220260300350405455505570615700780855885920985
1055
0.380.380.380.760.760.760.761.141.141.141.141.141.651.651.651.651.651.651.651.651.651.651.65
141210
86421
1/02/03/04/0
250300350400500600700750800900
1000
7777777
19191919193737373737616161616161
5.005.466.058.109.03
10.2111.7113.9814.9816.1117.3818.8021.5622.9124.1625.3228.1930.1531.9032.7433.5435.0936.53
385273
125178259386505617756930
114714011651189921452668315536423885412746115093
Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. 75°C for PE insulation, 90°C conductor temperature nfor XLPE insulation, 30°C ambient temperature, According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
DIAMETEROVER
JACKET(mm)
SIZEAWG /kcmil
DIAMETEROVER
INSULATION(mm)
JACKETTHICKNESS
(mm)
APPROX.TOTAL
WEIGHT(kg/km)
DCRESISTANCE
AT 20°C1
(ohm/km)
STRANDINGCLASS
XLPE INSULATIONPE INSULATION
CROSSSECTION
(mm2)
CONDUCTORDIAMETER
(mm)
INSULATIONTHICKNESS
(mm)
AMPACITY 2
(A)4AMPACITY 2
(A)3AMPACITY 2
(A)4AMPACITY 2
(A)3STRANDS
No.
22
Cables Type TTU 600VThermoplastic (or Thermoset) Insulation, Thermoplastic Jacket. Underground
Manufacturing Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.Power Cables rated 2000 volts or less for the Distribution of Electrical Energy.
164182205256293339398457496541591647714767816862975
105211211154118512461303
0.003230.005130.00815
0.01300.02060.03280.05210.06570.0829
0.1050.1320.1660.1960.2360.2750.3140.3930.4710.5500.5890.6280.7070.785
BBBBBBBBBBBBBBBBBBBBBBB
7089
112141178225283322361406456512558611661706789866935968
100010611117
4545455555555565656565657575757590909090909090
202535506585
115130150175200230255285310335380420460475490520545
3035507095
125170195230265310360405455505545620690755785815870935
253040557595
130150170195225260290320350380430475520535555585615
2.581.621.02
0.6410.4030.2530.1590.1260.100
0.07950.06300.05000.04230.03530.03020.02640.02120.01760.01510.01410.01320.01180.0106
35405580
105140190220260300350405455505570615700780855885920985
1055
1515153030303045454545456565656565656565656565
141210
86421
1/02/03/04/0
250300350400500600700750800900
1000
7777777
19191919193737373737616161616161
197215238319356402461551590634684740849902951997
1110118712561289132013821438
26354984
119174259340414508625771942
1109127614421793212024472611277430993423
DIAMETEROVER
JACKET(mils)
SIZEAWG /kcmil
DIAMETEROVER
INSULATION(mils)
JACKETTHICKNESS
(mils)
APPROX.TOTAL
WEIGHT(pounds/1000ft)
DCRESISTANCE
AT 20°C1
(ohm/1000ft)
STRANDING(mils)
XLPE INSULATIONPE INSULATION
CROSSSECTION(sq inches)
CONDUCTORDIAMETER
(mils)
INSULATIONTHICKNESS
(mils)
AMPACITY 2
(A)4AMPACITY 2
(A)3AMPACITY 2
(A)4AMPACITY 2
(A)3STRANDS
No.
Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. 75°C for PE insulation, 90°C conductor temperature nfor XLPE insulation, 30°C ambient temperature, According to NEC and NTC 2050,
for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. One single conductor at free air at 30°C ambient temperature.4. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature.5. According to NEC NTC 2050 the minimun size for use in Tray Cables must be 1/0 AWG for phase conductors, and 4 AWG for grounding conductors.6. Data herein indicated are approximated and are subject to normal manufacturing tolerances.
23
Cross (X) Linked Polyethilene Insulation, High Heat resistant (90°C), 2: Suitable for Dry and Wet Locations
Description
Three soft copper conductors PVC or XLPE insulated twisted and with overallPVC jacket.
Design
ConductorSoft stranded compressed copper.
InsulationPolyvinyl Chloride (PVC 75°C) flame retardant, for PVC-PVC insulation andjacket.Cross linked Polyethylene (XLPE 90°C), for XLPE-PVC insulation and jacket.
FillerFlame retardant Polyvinyl Chloride.
JacketFlame retardant Polyvinyl Chloride.
OptionsEPR insulation. Metallic shield in copper tape or copper wires. Groundingconductor- Armor in galvanized steel wires or galvanized steel tape or interlockedarmor tape aluminum or steel. Moisture barrier, PVC SR (Sunlight Resistant)jacket.
Characteristics
Operating temperatureDry and wet locations.75°C, for PVC-PVC insulation-jacket.90°C, for XLPE-PVC insulation-jacket.
Three Conductor Power CablesCross (X) Linked Polyethylene Insulation, High Heat resistant (90°C),2: Suitable for Dry and Wet Locations
24
Operating Voltage600 V.
Optional2000 V.
Uses and Applications
General purpose in industrial installations for Low Voltage indoordistribution of electrical energy in low tension. Installation in dry or wetlocations, in ducts, raceway or buried direct. The design of PowerCable 3 - conductor combines the excellent electrical properties ofPE, and electrical and mechanical of XLPE like insulation materials,and the mechanical properties and PVC flame in the outer jacket. Inspecial applications the cable can be used under water. XLPE insulatedconductors have minor total diameters for the same voltage of operation,that PVC isolated ones.
Standards and Specifications
CENTELSA Power Cables are manufactured under the followingstandards:
ASTM B3, NTC-ICONTEC 359. Soft copper wire.ASTM B8, NTC-ICONTEC 307. Concentric Lay Stranded copperconductors.ASTM B787. 19 Wire Combination Unilay Stranded Copper conductorsfor subsequent insulation.UL 1581, NTC-3203. Reference Standard for Electrical Wires, Cablesand Flexible Cords.ICEA S-95-658, NTC-ICONTEC 1099-1. Power Cables rated 2000volts or less for the Distribution of Electrical Energy.IEC 228. Conductors for insulated cables (mm2 sizes).IEC 60502-1. Cables for 1kV Voltages (mm2 sizes).
Certifications
CENTELSA Power Cables are certified by CIDET (Colombia). Cert.No. 1668.
25
Phases identification
PVC-PVC Cables are identified by colored phases black, white and red. Blackjacket.XLPE-PVC Cables are identified by numbered black phases. Black jacket.
Note: Other configurations and sizes not specified herein are available uponrequest.
Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. In race way, or direct burial, 75°C conductor temperature, 30°C ambient temperature.3. Data herein indicated are approximated and are subject to normal manufacturing tolerances.
6.757.688.87
10.3612.3613.3614.4915.7617.1819.1420.4821.7422.9025.00
8.3713.3021.1533.6342.4153.4867.4385.03107.2126.7152.0177.3202.7253.4
BBBBBBBBBBBBBB
3.594.525.717.208.189.18
10.3111.5813.0014.1815.5216.7817.9420.04
1.521.521.521.522.032.032.032.032.032.412.412.412.412.41
2.101.32
0.8310.5230.4150.3290.2610.2070.1640.1390.116
0.09920.08680.0694
541737
108915542007240830713702463955006392727881549886
17.7119.7223.2926.5030.8232.9737.4140.1444.7648.9851.8854.5957.0861.62
506585
115130150175200230255285310335380
14.5516.5619.1122.3226.6428.7931.2333.9637.0241.2444.1446.8549.3453.88
86421
1/02/03/04/0
250300350400500
7777
19191919193737373737
------
1.001.001.001.001.001.001.001.00
1.521.522.032.032.032.032.032.032.792.792.792.792.792.79
DIAMETEROVER
JACKET(mm)
SIZEAWG /kcmil
DIAMETEROVER
INSULATION(mm)
JACKETTHICKNESS
(mm)
APPROX.TOTAL
WEIGHT(kg/km)
DCRESISTANCE
AT 20°C1
(ohm/km)
STRANDINGCLASS
CROSSSECTION
(mm2)
CONDUCTORDIAMETER
(mm)
INSULATIONTHICKNESS
(mm)
AMPACITY 2
(A)STRANDS
No.ASSEMBLYDIAMETER
(mm)
FILLERTHICKNESS
(mm)
Three Conductors Cables PVC-PVC 600V (International Unit System)
Manufacturing Standard: ICEA S-95-658, NTC-ICONTEC 1099-1. Power Cables rated 2000 volts or less for the Distribution of Electrical Energy.
26
Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. In race way, or direct burial, 75°C conductor temperature, 30°C ambient temperature.3. Data herein indicated are approximated and are subject to normal manufacturing tolerances.
266303349408487526571620676753806856901984
0.01300.02060.03280.05210.06570.0829
0.1050.1320.1660.1960.2360.2750.3140.393
BBBBBBBBBBBBBB
141178225283322361406456512558611661706789
6060606080808080809595959595
0.6410.4030.2530.1590.1260.100
0.07950.06300.05000.04230.03530.03020.02640.0212
363496732
10441349161920642488311836964296489154806644
697776917
10431213129814731580176219282042214922472426
506585
115130150175200230255285310335380
573652752879
1049113312291337145716241738184519432121
86421
1/02/03/04/0
250300350400500
7777
19191919193737373737
------
3939393939393939
6060808080808080
110110110110110110
Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. In race way, or direct burial, 90°C conductor temperature, 30°C ambient temperature.3. Data herein indicated are approximated and are subject to normal manufacturing tolerances.
5.976.908.099.58
11.1012.1013.2314.5015.9217.6218.9620.2221.3823.48
8.3713.3021.1533.6342.4153.4867.4385.03107.2126.7152.0177.3202.7253.4
BBBBBBBBBBBBBB
3.594.525.717.208.189.18
10.3111.5813.0014.1815.5216.7817.9420.04
1.141.141.141.141.401.401.401.401.401.651.651.651.651.65
2.101.32
0.8310.5230.4150.3290.2610.2070.1640.1390.116
0.09920.08680.0694
460646930
14241787217126493409416550735936679576469333
16.0318.0420.5924.8228.1030.2532.6937.4340.4845.7048.6051.3253.8158.34
557595
130150170195225260290320350380430
12.8714.8817.4320.6423.9226.0728.5131.2534.3037.9640.8643.5846.0750.60
86421
1/02/03/04/0
250300350400500
7777
19191919193737373737
-------
1.001.001.001.001.001.001.00
1.521.521.522.032.032.032.032.032.032.792.792.792.792.79
Three Conductors Cables PVC-PVC 600V
Manufacturing Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.Power Cables rated 2000 volts or less for the Distribution of Electrical Energy.
DIAMETEROVER
JACKET(mils)
SIZEAWG /kcmil
DIAMETEROVER
INSULATION(mils)
JACKETTHICKNESS
(mils)
APPROX.TOTAL
WEIGHT(pound/1000ft)
DCRESISTANCE
AT 20°C1
(ohm/1000ft)
STRANDING(mils)
CROSSSECTION(sq inches)
CONDUCTORDIAMETER
(mils)
INSULATIONTHICKNESS
(mils)
AMPACITY 2
(A)STRANDS
No.ASSEMBLYDIAMETER
(mils)
FILLERTHICKNESS
(mils)
Three Conductors Cables XLPE-PVC 600V (International Unit System)
Manufacturing Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.Power Cables rated 2000 volts or less for the Distribution of Electrical Energy.
DIAMETEROVER
JACKET(mm)
SIZEAWG /kcmil
DIAMETEROVER
INSULATION(mm)
JACKETTHICKNESS
(mm)
APPROX.TOTAL
WEIGHT(kg/km)
DCRESISTANCE
AT 20°C1
(ohm/km)
STRANDINGCLASS
CROSSSECTION
(mm2)
CONDUCTORDIAMETER
(mm)
INSULATIONTHICKNESS
(mm)
AMPACITY 2
(A)STRANDS
No.ASSEMBLYDIAMETER
(mm)
FILLERTHICKNESS
(mm)
27
235272318377437476521571627694747796842924
0.01300.02060.03280.05210.06570.0829
0.1050.1320.1660.1960.2360.2750.3140.393
BBBBBBBBBBBBBB
141178225283322361406456512558611661706789
4545454555555555556565656565
0.6410.4030.2530.1590.1260.100
0.07950.06300.05000.04230.03530.03020.02640.0212
309434625957
1201145917802291279934093989456751396272
631710810977
1106119112871474159417991914202021182297
557595
130150170195225260290320350380430
507586686813942
102611231230135014951609171618141992
86421
1/02/03/04/0
250300350400500
7777
19191919193737373737
-------
39393939393939
606060808080808080
110110110110110
Notes: 1. Designated Voltage Uo/U means Uo rated voltage phase-neutral, U rated voltage phase-phase.2. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.3. In race way, or direct burial, 75°C conductor temperature, 30°C ambient temperature.4. Data herein indicated are approximated and are subject to normal manufacturing tolerances.
5.826.808.389.46
11.1812.6914.7116.2018.1420.1522.83
10.016.025.035.050.070.095.0
120.0150.0185.0240.0
22222222222
3.724.705.886.968.269.77
11.3912.8814.4015.9918.29
1.001.001.201.201.401.401.601.601.802.002.20
1.761.10
0.7030.5020.3520.2510.1850.1470.117
0.09510.0733
530752
111514682018272437224600570770148996
16.2818.3921.8024.1327.8331.5137.0240.6545.0349.7855.96
507090
110140170205240275310365
12.5414.6518.0620.3924.0927.3531.7034.9139.0943.4249.20
10162535507095
120150185240
7777
19191937373737
------
0.500.500.500.500.50
1.801.801.801.801.802.002.102.302.402.602.80
Three Conductors Cables XLPE-PVC 600V
Manufacturing Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.Power Cables rated 2000 volts or less for the Distribution of Electrical Energy.
Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. In race way, or direct burial, 90°C conductor temperature, 30°C ambient temperature.3. Data herein indicated are approximated and are subject to normal manufacturing tolerances.
DIAMETEROVER
JACKET(mils)
SIZEAWG /kcmil
DIAMETEROVER
INSULATION(mils)
JACKETTHICKNESS
(mils)
APPROX.TOTAL
WEIGHT(pound/1000ft)
DCRESISTANCE
AT 20°C1
(ohm/1000ft)
STRANDING(mils)
CROSSSECTION(sq inches)
CONDUCTORDIAMETER
(mils)
INSULATIONTHICKNESS
(mils)
AMPACITY 2
(A)STRANDS
No.ASSEMBLYDIAMETER
(mils)
FILLERTHICKNESS
(mils)
Three Conductor Power Cable Type PVC-PVC 0.6/1 kV ( mm2 Sizes)
Manufacturing Standard: IEC 60502-1 Cables for 1 kV Voltages.
DIAMETEROVER
JACKET(mm)
SIZEAWG /kcmil
DIAMETEROVER
INSULATION(mm)
JACKETTHICKNESS
(mm)
APPROX.TOTAL
WEIGHT(kg/km)
DCRESISTANCE
AT 20°C1
(ohm/km)
STRANDINGCLASS
CROSSSECTION
(mm2)
CONDUCTORDIAMETER
(mm)
INSULATIONTHICKNESS
(mm)
AMPACITY 2
(A)STRANDS
No.ASSEMBLYDIAMETER
(mm)
FILLERTHICKNESS
(mm)
28
Notes: 1. Designated Voltage Uo/U means Uo rated voltage phase-neutral, U rated voltage phase-phase.2. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.3. In race way, or direct burial, 90°C conductor temperature, 30°C ambient temperature.4. Data herein indicated are approximated and are subject to normal manufacturing tolerances.
5.206.187.788.86
10.3612.0513.6715.3817.3219.3121.83
10.016.025.035.050.070.095.0
120.0150.0185.0240.0
22222222222
3.724.705.886.968.269.77
11.3912.8814.4015.9918.29
0.700.700.900.901.001.101.101.201.401.601.70
1.761.10
0.7030.5020.3520.2510.1850.1470.117
0.09510.0733
473686
103313751883257834114373544567078602
14.9517.0620.5122.8326.0729.9333.6238.6843.0647.7753.60
6080
105130160195235270310350410
11.2113.3216.7719.0922.3325.9729.4633.1437.3241.6147.04
10162535507095
120150185240
7777
19191937373737
-------
0.500.500.500.50
1.801.801.801.801.801.902.002.202.302.502.70
Three Conductor Power Cable Type XLPE-PVC 0.6/1 kV ( mm2 Sizes)
Manufacturing Standard: IEC 60502-1 Cables for 1 kV Voltages.
DIAMETEROVER
JACKET(mm)
SIZEAWG /kcmil
DIAMETEROVER
INSULATION(mm)
JACKETTHICKNESS
(mm)
APPROX.TOTAL
WEIGHT(kg/km)
DCRESISTANCE
AT 20°C1
(ohm/km)
STRANDINGCLASS
CROSSSECTION
(mm2)
CONDUCTORDIAMETER
(mm)
INSULATIONTHICKNESS
(mm)
AMPACITY 2
(A)STRANDS
No.ASSEMBLYDIAMETER
(mm)
FILLERTHICKNESS
(mm)
29
Service EntranceType SEU & SERService Entrance Cable Unarmored or U-shapedService Entrance Cable Round
Description
Service Entrance SEU: one or two XHHW-2 insulated conductors, paralleled,with concentric neutral, reinforced tape and PVC jacket.
Service Entrance SER: two or three XHHW-2 insulated conductors, twistedtogether with or without bare grounding conductor, reinforced tape and PVCjacket.
Construction
ConductorSoft copper stranded and compressed.
InsulationCross Linked Polyethylene (XLPE 90°C).
Design
Service Entrance Type U, SEU: Round configuration for one phase conductorand neutral, flan configuration for two phase conductors and neutral.
NeutralService Entrance SEU : soft copper wires applied concentrically around phaseswith SZ technology (UL 854 Section 15.4)Service Entrance SER: soft copper stranded, twisted together with phases
Binder TapeService Entrance SEU: polyester tape over neutral conductorService Entrance SER: polyester tape over assembly.
30
JacketFlame Retardant and Sunlight resistant PVC.
OptionsTHWN-2 Conductors. Jacket with PVC LS (LOW Smoke emission).Aluminum conductors.
Characteristics
Operating TemperatureDry and wet locations 90°C.Operating Voltage600 V.
Uses and Applications
Service Entrance or Drop Cable up to Service Entrance Equipmentand to general breaker. May be used for branch circuits according toNEC and NTC 2050.
Standards and Specifications
CENTELSA Service Entrance Cables are manufactured under thefollowing standards:
ASTM B3, NTC-359. Soft copper wires.ASTM B8, NTC-307. Concentric Lay Stranded copper conductors.ASTM B787. 19 Wire Combination Unilay Stranded Copper conductorsfor subsequent insulationUL 1581, NTC-3203. Reference Standard for Electrical Wires, Cablesand Flexible Cords.UL 854, NTC-ICONTEC 4564. Service Entrance Cables.
Certifications
CENTELSA Service Entrance Cables are certified by:
UL 854 File E207803.CIDET (Colombia). Cert. No. 00416.
Note: Other configurations and sizes not specified herein are availableupon request.
31
Service Entrance Type SEU 600VService Entrance Cable Unarmored or U-shaped
Manufacturing Standard: UL 854, NTC 4564. Service Entrance Cables
Service Entrance Type SEU 600V (International System Unit)Service Entrance Cable Unarmored or U-shaped
Manufacturing Standard: UL 854, NTC 4564. Service Entrance Cables
Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature, 90°C conductor temperature. According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. LData herein indicated are approximated and are subject to normal manufacturing tolerances.
Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2.No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature, 90°C conductor temperature. According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. LData herein indicated are approximated and are subject to normal manufacturing tolerances.
4.185.966.898.089.574.185.966.898.089.575.966.898.089.57
5.268.37
13.3021.1533.63
5.268.37
13.3021.1533.63
8.3713.3021.1533.63
SOLIDBBBB
SOLIDBBBBBBBB
2.593.594.525.717.202.593.594.525.717.203.594.525.717.20
0.761.141.141.141.140.761.141.141.141.141.141.141.141.14
3.282.101.32
0.8310.523
3.282.101.32
0.8310.523
2.101.32
0.8310.523
6.829.36
10.5612.0813.99
6.90 x 11.089.45 x 15.42
10.65 x 17.5412.17 x 20.2514.09 x 23.66
9.45 x 15.4210.38 x 17.2811.83 x 19.9113.66 x 23.23
0.761.141.141.141.140.761.141.141.141.141.141.141.141.14
40557595
13040557595
130557595
130
108642
108642
10864
108642
1086428642
17777177777777
0.510.510.640.811.020.510.510.640.811.020.510.510.640.81
0.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.0320.032
1 x 10 + 101 x 8 + 81 x 6 + 61 x 4 + 41 x 2 + 2
2 x 10 + 102 x 8 + 82 x 6 + 62 x 4 + 42 x 2 + 2
2 x 8 + 102 x 6 + 82 x 4 + 62 x 2 + 4
126216316475721195338492733
1107309445657989
2641414141264141414126414141
165235271318377165235271318377235271318377
0.008150.01300.02060.03280.0521
0.008150.01300.02060.03280.05210.01300.02060.03280.0521
SOLIDBBBB
SOLIDBBBBBBBB
102141178225283102141178225283141178225283
3045454545304545454545454545
0.9990.6410.4030.2530.1590.9990.6410.4030.2530.1590.6410.4030.2530.159
269369416476551
272 x 436372 x 607419 x 691479 x 797555 x 931372 x 607409 x 680466 x 784538 x 915
3045454545304545454545454545
40557595
13040557595
130557595
130
108642
108642
10864
108642
1086428642
17777177777777
20.120.125.332.040.320.120.125.332.040.320.120.125.332.0
1.31.31.31.31.31.31.31.31.31.31.31.31.31.3
1 x 10 + 101 x 8 + 81 x 6 + 61 x 4 + 41 x 2 + 2
2 x 10 + 102 x 8 + 82 x 6 + 62 x 4 + 42 x 2 + 2
2 x 8 + 102 x 6 + 82 x 4 + 62 x 2 + 4
85145213319484131227331493744208299441664
2641414141264141414126414141
JACKETTHICKNESS
(mm)
SIZEAWG
DIAMETEROVER
INSULATION(mm)
POLYESTERICTAPE
THICKNESS(mm)
APPROX.TOTAL
WEIGHT(kg/km)
DCRESISTANCE
AT 20°C1
(ohm/km)
CROSSSECTION
(mm2)
CONDUCTORDIAMETER
(mm)
INSULATIONTHICKNESS
(mm)
AMPACITY 2
(A)
STRA
NDS
No.
NEUTRALSIZEAWG STRANDS
No.
CODE DIMENSIONSOVER
JACKET(mm)
NEUTRAL CONDUCTOR
STRANDDIAMETER
(mm)
STRA
NDIN
GCL
ASS
JACKETTHICKNESS
(mils)
SIZEAWG
DIAMETEROVER
INSULATION(mils)
POLYESTERICTAPE
THICKNESS(mils)
APPROX.TOTAL
WEIGHT(pound/1000ft)
DCRESISTANCE
AT 20°C1
(ohm/1000ft)
CROSSSECTION(sq inches)
CONDUCTORDIAMETER
(mils)
INSULATIONTHICKNESS
(mils)
AMPACITY 2
(A)
STRA
NDS
No.
NEUTRALSIZEAWG STRANDS
No.
CODE DIMENSIONSOVER
JACKET(mils)
NEUTRAL CONDUCTOR
STRANDDIAMETER
(mils)
STRA
NDIN
G(m
ils)
32
Service Entrance Type SER 600VService Entrance Cable Round
Manufacturing Standard: UL 854, NTC 4564. Service Entrance Cables
Service Entrance Type SER 600V (International System Unit)Service Entrance Cable Round
Manufacturing Standard: UL 854, NTC 4564. Service Entrance Cables
Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature, 90°C conductor temperature.
According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
5.966.898.089.57
11.0912.0913.2214.4915.91
5.966.898.089.57
12.0913.2214.4915.91
8.3713.3021.1533.6342.4153.4867.4385.03107.2
8.3713.3021.1533.6353.4867.4385.03107.2
BBBBBBBBBBBBBBBBB
3.594.525.717.208.189.18
10.3111.5813.00
3.594.525.717.209.18
10.3111.5813.00
1.141.141.141.141.401.401.401.401.401.141.141.141.141.401.401.401.40
2.121.34
0.8400.5280.4190.3320.2630.2090.166
2.121.34
0.8400.5280.3320.2630.2090.166
14.7516.7519.3022.5225.8027.9530.3933.1336.1815.6117.7520.4723.9129.7032.3135.2338.49
0.760.760.760.760.760.760.760.760.760.760.760.760.760.760.760.760.76
557595
130150170195225260
557595
130170195225260
---------866421
1/02/0
86421
1/02/03/04/0
8642
1/02/03/04/0
7777
1919191919
7777
19191919
---------77777
191919
0.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.1000.100
3 x 83 x 63 x 43 x 23 x 1
3 x 1/03 x 2/03 x 3/03 x 4/0
3 x 8 + 83 x 6 + 63 x 4 + 63 x 2 + 4
3 x 1/0 + 23 x 2/0 + 1
3 x 3/0 + 1/03 x 4/0 + 2/0
344501744
112414111740215326693317
424626870
13232055254831673943
---------
3.594.524.525.717.208.189.18
10.31
12.8514.8617.4120.6223.9026.0528.5031.2334.2813.7215.8618.5822.0127.8130.4133.3336.59
235271318377437476521571626235271318377476521571626
0.01300.02060.03280.05210.06570.0829
0.1050.1320.166
0.01300.02060.03280.05210.0829
0.1050.1320.166
BBBBBBBBBBBBBBBBB
141178225283322361406456512141178225283361406456512
4545454555555555554545454555555555
0.6470.4070.2560.1610.1280.101
0.08030.06370.0505
0.6470.4070.2560.1610.101
0.08030.06370.0505
581660760887
10161100119713041424
615699806941
1169127213871515
3030303030303030303030303030303030
557595
130150170195225260
557595
130170195225260
---------866421
1/02/0
86421
1/02/03/04/0
8642
1/02/03/04/0
7777
1919191919
7777
19191919
---------77777
191919
3.93.93.93.93.93.93.93.93.93.93.93.93.93.93.93.93.9
3 x 83 x 63 x 43 x 23 x 1
3 x 1/03 x 2/03 x 3/03 x 4/0
3 x 8 + 83 x 6 + 63 x 4 + 63 x 2 + 4
3 x 1/0 + 23 x 2/0 + 1
3 x 3/0 + 1/03 x 4/0 + 2/0
231336500755948
1170144717942229
285421585889
1381171321282650
---------
141178178225283322361406
506585685812941
1026112212301350
540624731867
1095119713121441
Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature, 90°C conductor temperature. According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
JACKETTHICKNESS
(mm)
SIZEAWG
DIAMETEROVER
INSULATION(mm)
REINFORCEDTAPE
THICKNESS(mm)
APPROX.TOTAL
WEIGHT(Kg/Km)
DCRESISTANCE
AT 20°C1
(ohm/Km)
CROSSSECTION
(mm2)
CONDUCTORDIAMETER
(mm)
INSULATIONTHICKNESS
(mm)
AMPACITY 2
(A)NEUTRAL
SIZEAWG
NEUTRALCONDUCTOR
STRANDSNo.
CODE DIMENSIONSOVER
JACKET(mm)
NEUTRALCONDUCTOR
DIAMETERNo.
ASSEMBLYDIAMETER
(mm)
STRA
NDS
No.
STRA
NDIN
GCL
ASS
JACKETTHICKNESS
(mils)
SIZEAWG
DIAMETEROVER
INSULATION(mils)
REINFORCEDTAPE
THICKNESS(mils)
APPROX.TOTAL
WEIGHT(pound/1000ft)
DCRESISTANCE
AT 20°C1
(ohm/1000ft)
CROSSSECTION(sq inches)
CONDUCTORDIAMETER
(mils)
INSULATIONTHICKNESS
(mils)
AMPACITY 2
(A)NEUTRAL
SIZEAWG
NEUTRALCONDUCTOR
STRANDSNo.
CODE DIMENSIONSOVER
JACKET(mils)
NEUTRALCONDUCTOR
DIAMETERNo.
ASSEMBLYDIAMETER
(mils)
STRA
NDS
No.
STRA
NDIN
G(m
ils)
33
Description
ARE: one or two XLPE insulated conductors, twisted together, with concentricneutral, PVC filler and PE jacket.
APE: two XLPE insulated conductors, paralleled, with polyester tape, concentricneutral, and PE jacket.
Service Entrance SER: two or three XHHW-2 insulated conductors, twistedtogether with or without bare grounding conductor, reinforced tape and PVCjacket.
Construction
ConductorSoft copper stranded and compressed.InsulationCross Linked Polyethylene (XLPE 90°C).ConfigurationARE: Round.APE: Flat.Binder TapeAPE: Polyester Tape over paralleled conductors.NeutralSoft copper wires applied concentrically around phases with SZ technologywith high coverage over phase conductors.JacketPolyethylene (PE). Rip cord for easy installation.OptionsAluminum conductor. PVC Insulation. Sunlight Resistant PVC Jacket.
Service EntranceType ARE & APEA: Service Entrance R: Round Configuration E: Concentric Neutral ConductorA: Service Entrance P: Flat Configuration E: Concentric Neutral Conductor
34
Low Smoke Emission PVC Jacket.
Characteristics
Operation TemperatureDry and wet locations 90°C.Operating Voltage600 V.
Uses and Applications
Service Entrance or Drop Cable up to Service Entrance Equipmentand to general breaker.
Standards
CENTELSA ARE and APE Service Entrance Cables are manufacturedunder the following standards:
ASTM B3, NTC-359. Soft copper wires.ASTM B8, NTC-307. Concentric Lay Stranded copper conductors.
Certifications
CENTELSA ARE and APE Service Entrance Cables are certified by:CIDET (Colombia). Cert. No. 00416.
Note: Other configurations and sizes not specified herein are availableupon request.
35
Service Entrance Type ARE 600V (International System Unit)A: Service Entrance R: Round Configuration E: Concentric Neutral Conductor
Standard: ICEA S-95-658, NTC-ICONTEC 1099-1. Power Cables rated 2000 volts or less for the Distribution of Electrical Energy
Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature, 90°C conductor temperature. According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature, 90°C conductor temperature. According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
Service Entrance Type ARE 600VA: Service Entrance R: Round Configuration E: Concentric Neutral Conductor
Standard: ICEA S-95-658, NTC-ICONTEC 1099-1. Power Cables rated 2000 volts or less for the Distribution of Electrical Energy
JACKETTHICKNESS
(mm)
SIZEAWG
DIAMETEROVER
INSULATION(mm)
STRANDSNo.
APPROX.TOTAL
WEIGHT(kg/km)
DCRESISTANCE
AT 20°C1
(ohm/km)
STRA
NDIN
GCL
ASS CROSS
SECTION(mm2)
CONDUCTORDIAMETER
(mm)
INSULATIONTHICKNESS
(mm)
AMPACITY 2
(A)
STRA
NDS N
o. FILLERTHICKNESS
(mm)
DIAMETEROVER
FILLER(mm)
CODE DIMENSIONSOVER
JACKET(mm)
NEUTRALSIZEAWG
NEUTRAL CONDUCTOR
STRANDDIAMETER
(mm)
3.654.185.966.898.089.573.654.185.966.898.089.57
3.315.268.37
13.3021.1533.63
3.315.268.37
13.3021.1533.63
SOLIDSOLID
BBBB
SOLIDSOLID
BBBB
2.052.593.594.525.717.202.052.593.594.525.717.20
0.760.761.141.141.141.140.760.761.141.141.141.14
5.213.282.101.320.830.525.213.282.101.32
0.8310.523
7.047.589.36
10.2911.7314.36
7.047.589.36
10.2911.7314.36
1.141.141.141.141.141.521.141.141.141.141.141.52
3040557595
1303040557595
130
------
0.500.500.500.500.500.50
1210
8642
1210
8642
117777117777
3.654.185.966.898.089.578.309.37
12.9314.7917.1520.14
172641414141262641414141
1 x 12 + 121 x 10 + 10
1 x 8 + 81 x 6 + 81 x 4 + 61 x 2 + 4
2 x 12 + 122 x 10 + 10
2 x 8 + 82 x 6 + 82 x 4 + 62 x 2 + 4
88126202254382598173243408543794
1200
1210
8864
1210
8864
0.510.510.510.510.640.810.510.510.510.510.640.81
144165235271318377144165235271318377
0.005130.00815
0.01300.02060.03280.0521
0.005130.00815
0.01300.02060.03280.0521
SOLIDSOLID
BBBB
SOLIDSOLID
BBBB
81102141178225283
81102141178225283
303045454545303045454545
1.590.9990.6410.4030.2530.159
1.590.9990.6410.4030.2530.159
277298368405462565277298368405462565
454545454560454545454560
3040557595
1303040557595
130
------
202020202020
1210
8642
1210
8642
117777117777
144165235271318377327369509582675793
172641414141262641414141
1 x 12 + 121 x 10 + 10
1 x 8 + 81 x 6 + 81 x 4 + 61 x 2 + 4
2 x 12 + 122 x 10 + 10
2 x 8 + 82 x 6 + 82 x 4 + 62 x 2 + 4
5985
136171257402117163274365534807
1210
8864
1210
8864
20.120.120.120.125.332.020.120.120.120.125.332.0
JACKETTHICKNESS
(mils)
SIZEAWG
DIAMETEROVER
INSULATION(mils)
STRANDSNo.
APPROX.TOTAL
WEIGHT(pound/1000ft)
DC RESISTANCEAT 20°C1
(ohm/1000ft)STRA
NDIN
G(m
ils)
CROSSSECTION
(sq inches2)
CONDUCTORDIAMETER
(mils)
INSULATIONTHICKNESS
(mils)
AMPACITY 2
(A)
STRA
NDS N
o. FILLERTHICKNESS
(mils)
DIAMETEROVER
FILLER(mils)
CODE DIMENSIONSOVER
JACKET(mils)
NEUTRALSIZEAWG
NEUTRAL CONDUCTOR
STRANDDIAMETER
(mils)
36
Service Entrance Type APE 600V (International System Unit)A: Service Entrance P: Flat Configuration E: Concentric Neutral Conductor
Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.Power Cables rated 2000 volts or less for the Distribution of Electrical Energy
Notes: 1. DC resistance calculated based on a 17.241 ohm-mm2/km resistivity for cooper.2.No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature, 90°C conductor temperature. According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
4.185.966.898.089.575.966.898.089.57
5.268.37
13.3021.1533.63
8.3713.3021.1533.63
SOLIDBBBBBBBB
2.593.594.525.717.203.594.525.717.20
0.761.141.141.141.141.141.141.141.14
3.282.101.32
0.8310.523
2.101.32
0.8310.523
7.67 x 11.869.45 x 15.42
10.65 x 17.5412.17 x 20.2514.09 x 23.66
9.45 x 15.4210.38 x 17.2811.83 x 19.9113.66 x 23.23
1.141.141.141.141.141.141.141.141.14
40557595
130557595
130
1086428642
177777777
0.0320.0320.0320.0320.0320.0320.0320.0320.032
264141414126414141
2 x 10 + 102 x 8 + 82 x 6 + 62 x 4 + 42 x 2 + 2
2 x 8 + 102 x 6 + 82 x 4 + 62 x 2 + 4
196316467704
1072288420628955
108642
10864
JACKETTHICKNESS
(mm)
SIZEAWG
DIAMETEROVER
INSULATION(mm)
NEUTRALCONDUCTOR
STRANDSNo.
APPROX.TOTAL
WEIGHT(kg/km)
DCRESISTANCE
AT 20°C1
(ohm/km)
STRA
NDIN
GCL
ASS CROSS
SECTION(mm2)
CONDUCTORDIAMETER
(mm)
INSULATIONTHICKNESS
(mm)
AMPACITY 2
(A)
STRA
NDS
No.
POLYESTERICTAPE
THICKNESS(mm)
CODE DIMENSIONSOVER
JACKET(mm)
NEUTRALSIZEAWG
Notes: 1. DC resistance calculated based on a 10,371 ohm-cmil/1000ft resistivity for cooper.2. No more than three current carrying conductors in a duct or in direct burial, 30°C ambient temperature, 90°C conductor temperature. According to NEC and NTC 2050, for sizes 14 12 and 10 AWG overload protection must be 15, 20 and 30 A.3. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
Service Entrance Type APE 600VA: Service Entrance P: Flat Configuration E: Concentric Neutral Conductor
Standard: ICEA S-95-658, NTC-ICONTEC 1099-1.Power Cables rated 2000 volts or less for the Distribution of Electrical Energy
165235271318377235271318377
0.008150.01300.02060.03280.05210.01300.02060.03280.0521
SOLIDBBBBBBBB
102141178225283141178225283
304545454545454545
0.9990.6410.4030.2530.1590.6410.4030.2530.159
302 x 467372 x 607419 x 691479 x 797555 x 931372 x 607409 x 680466 x 784538 x 915
454545454545454545
40557595
130557595
130
1086428642
177777777
1.31.31.31.31.31.31.31.31.3
264141414126414141
2 x 10 + 102 x 8 + 82 x 6 + 62 x 4 + 42 x 2 + 2
2 x 8 + 102 x 6 + 82 x 4 + 62 x 2 + 4
132212314473721193282422642
108642
10864
SIZEAWG
NEUTRALCONDUCTOR
STRANDSNo.
POLYESTERICTAPE
THICKNESS(mils)
CONSTRUCTION
STRA
NDIN
GCL
ASS
STRA
NDS
No. CROSS
SECTION(sq inches2)
CONDUCTORDIAMETER
(mils)
INSULATIONTHICKNESS
(mils)
DIAMETEROVER
INSULATION(mils)
NEUTRALSIZEAWG
DCRESISTANCE
AT 20°C1
(ohm/1000ft)
AMPACITY 2
(A)APPROX.
TOTALWEIGHT
(pound/1000ft)
DIMENSIONSOVER
JACKET(mils)
JACKETTHICKNESS
(mils)
37
Description
Aluminum conductors PE or XLPE insulated twisted together with a neutralsupporting Messenger in AAC, AAAC or ACSR.
Construction
ConductorConcentrically stranded, compressed 1350-H19 Aluminum. Duplex one phaseconductor, Triplex two phase conductor, Quadruplex three phase conductors.
InsulationCross Linked Polyethylene (XLPE 90°C) or thermoplastic polyethylene (PE75°C).
Neutral supporting messengerAAC All Aluminum Conductor, AAAC All Aluminum Alloy Conductor or ACSRAluminum conductor steel reinforced.
OptionsPhase conductor in AAAC. Neutral covered. Additional conductor for Publiclighting system. Overall Jacket.
Characteristics
Operating Temperature990°C, for XLPE insulation.75°C, for PE insulation.
Operating Voltage600 V.
Neutral SupportedMultiplex Cable
38
Applications
Duplex: Overhead Secondary Distribution, street lighting, outdoorlighting or temporally installations.
Triplex: Overhead Secondary Distribution, from pole to service entrancederivation.
Quadruplex: Overhead Secondary Distribution Three-phase system,from pole to service entrance derivation.
Standards
CENTELSA MULTIPLEX Cables are manufactured under the followingstandards:ASTM B231, NTC-308. Concentric-Lay-Stranded Aluminum 1350ConductorsICEA S-76-474. Neutral supported power cables assemblies withweather resistant extruded insulation rated 600 volts.
Certifications
CENTELSA MULTIPLEX Cables are certified by:CIDET (Colombia). Certificate No. 01336 ICEA S-76-474.
Note: Other configurations and sizes not specified herein are availableupon request.
39
Neutral Supported Duplex 600V (International System Unit)
Manufacturing Standard: ICEA S-76-474. Neutral supported power cables assemblieswith weather resistant extruded insulation rated 600 volts.
Notes: 1. DC resistance calculated based on a 28,172 ohm-mm2/km resistivity for aluminum.2. 40°C Ambient temperature, 610 mm/seg wind speed, at sea level at 60 Hz.3. 75°C conductor temperature.4. 90°C conductor temperature.5. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
STRANDSNo.
CODE DIAMETEROVER
INSULATION(mm)
SIZEAWG /kcmil
APPROX.TOTAL
WEIGHT(kg/km)
DCRESISTANCE
AT 20°C1
(ohm/km)
STRANDINGCLASS
CROSSSECTION
(mm2)
CONDUCTORDIAMETER
(mm)
INSULATIONTHICKNESS
(mm)
AMPACITY 2
(A)3STRANDS
No. TYPE
AMPACITY 2
(A)4SIZE
AWG /kcmil
SELF SUPPORTING NEUTRAL
TENSILESTRENGTH
(kg)
6.506.907.578.099.58
12.346.506.907.578.099.58
12.346.506.907.578.099.58
12.34
13.3013.3021.1521.1533.6353.4813.3013.3021.1521.1533.6353.4813.3013.3021.1521.1533.6353.48
SOLIDB
SOLIDBBB
SOLIDB
SOLIDBBB
SOLIDB
SOLIDBBB
4.124.525.195.717.209.184.124.525.195.717.209.184.124.525.195.717.209.18
1.141.141.141.141.141.521.141.141.141.141.141.521.141.141.141.141.141.52
2.122.161.331.36
0.8540.537
2.122.161.331.36
0.8540.537
2.122.161.331.36
0.8540.537
95100142149227360112117170177271429101105152159242384
777777
6/16/16/16/16/16/1
777777
70709090
120160
70709090
120160
70709090
120160
AAC
ACSR
AAAC
PEKINGESECOLLIE
DACHSHUNDSPANIEL
DOBERMANMALEMUTE
SETTERSHEPHERD
ESKIMOTERRIER
CHOWBULL
CHIHUAHUAVIZSLA
HARRIERWHIPPET
SCHNAUZERHEELER
17177
1917177
1917177
19
8585
115115150205
8585
115115150205
8585
115115150205
66442
1/066442
1/030.5830.5848.6948.6977.47123.3
66442
1/066442
1/066442
1/0
256256400400613903540540845845
12941986
502502799799
12721939
40
256272298318377486256272298318377486256272298318377486
0.02060.02060.03280.03280.05210.08290.02060.02060.03280.03280.05210.08290.02060.02060.03280.03280.05210.0829
SOLIDB
SOLIDBBB
SOLIDB
SOLIDBBB
SOLIDB
SOLIDBBB
162178204225283361162178204225283361162178204225283361
454545454560454545454560454545454560
0.6460.6580.4060.4140.2600.1640.6460.6580.4060.4140.2600.1640.6460.6580.4060.4140.2600.164
646796
100153242
7578
114119182289
6871
102107163258
777777
6/16/16/16/16/16/1
777777
70709090
120160
70709090
120160
70709090
120160
AAC
ACSR
AAAC
PEKINGESECOLLIE
DACHSHUNDSPANIEL
DOBERMANMALEMUTE
SETTERSHEPHERD
ESKIMOTERRIER
CHOWBULL
CHIHUAHUAVIZSLA
HARRIERWHIPPET
SCHNAUZERHEELER
17177
1917177
1917177
19
8585
115115150205
8585
115115150205
8585
115115150205
66442
1/066442
1/030.5830.5848.6948.6977.47123.3
66442
1/066442
1/066442
1/0
564564882882
13511991119011901863186328534378110711071761176128044275
Notes: 1. DC resistance calculated based on a 16,946 ohm-mm2/km resistivity for aluminum.2. 40°C Ambient temperature, 610 mm/seg wind speed, at sea level at 60 Hz.3. 75°C conductor temperature.4. 90°C conductor temperature.5. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
Neutral Supported Duplex 600V
Manufacturing Standard: ICEA S-76-474. Neutral supported power cablesassemblies with weather resistant extruded insulation rated 600 volts.
6.506.907.578.099.58
12.34
13.3013.3021.1521.1533.6353.48
SOLIDB
SOLIDBBB
4.124.525.195.717.209.18
1.141.141.141.141.141.52
2.122.161.331.36
0.8540.537
153162226240361582
777777
70709090
120160
AAC
HAIOTISPATELLAFUSUS
OYSTERCLAM
MUREX
171777
8585
115115150205
66442
1/0
66442
1/0
256256400400613903
Neutral Supported Triplex 600V (International System Unit)
Manufacturing Standard: ICEA S-76-474. Neutral supported power cablesassemblies with weather resistant extruded insulation rated 600 volts.
Continued on page 41
STRANDSNo.
CODE DIAMETEROVER
INSULATION(mils)
SIZEAWG /kcmil
APPROX.TOTAL
WEIGHT(pound/1000ft)
DCRESISTANCE
AT 20°C1
(ohm/1000ft)
STRANDING(mils)
CROSSSECTION(sq inches)
CONDUCTORDIAMETER
(mils)
INSULATIONTHICKNESS
(mils)
AMPACITY 2
(A)3STRANDS
No. TYPE
AMPACITY 2
(A)4SIZE
AWG /kcmil
SELF SUPPORTING NEUTRAL
TENSILESTRENGTH
(pound)
STRANDSNo.
CODE DIAMETEROVER
INSULATION(mm)
SIZEAWG /kcmil
APPROX.TOTAL
WEIGHT(Kg/Km)
DCRESISTANCE
AT 20°C1
(ohm/Km)
STRANDINGCLASS
CROSSSECTION
(mm²)
CONDUCTORDIAMETER
(mm)
INSULATIONTHICKNESS
(mm)
AMPACITY 2
(A)3STRANDS
No. TYPE
AMPACITY 2
(A)4SIZE
AWG /kcmil
SELF SUPPORTING NEUTRAL
TENSILESTRENGTH
(Kg)
41
Notes: 1. DC resistance calculated based on a 28,172 ohm-mm2/km resistivity for aluminum.2. 40°C Ambient temperature, 610 mm/seg wind speed, at sea level at 60 Hz.3. 75°C conductor temperature.4. 90°C conductor temperature.5. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
12.3413.4713.4714.7416.1620.57
6.506.907.578.099.58
12.3412.3413.4713.4714.7416.1620.57
7.578.099.58
12.3412.3413.4713.4714.7416.1620.57
6.506.907.578.099.58
12.3412.3413.4713.4714.7416.16
7.578.099.58
12.3412.3413.4713.4714.7416.16
53.4867.4367.4385.03107.2170.513.3013.3021.1521.1533.6353.4853.4867.4367.4385.03107.2170.521.1521.1533.6353.4853.4867.4367.4385.03107.2170.513.3013.3021.1521.1533.6353.4853.4867.4367.4385.03107.221.1521.1533.6353.4853.4867.4367.4385.03107.2
BBBBBB
SOLIDB
SOLIDBBBBBBBBB
SOLIDBBBBBBBBB
SOLIDB
SOLIDBBBBBBBB
SOLIDBBBBBBBB
9.1810.3110.3111.5813.0016.39
4.124.525.195.717.209.189.18
10.3110.3111.5813.0016.39
5.195.717.209.189.18
10.3110.3111.5813.0016.39
4.124.525.195.717.209.189.18
10.3110.3111.5813.00
5.195.717.209.189.18
10.3110.3111.5813.00
1.521.521.521.521.522.031.141.141.141.141.141.521.521.521.521.521.522.031.141.141.141.521.521.521.521.521.522.031.141.141.141.141.141.521.521.521.521.521.521.141.141.141.521.521.521.521.521.52
0.5370.4260.4260.3380.2680.169
2.122.161.331.36
0.8540.5370.5370.4260.4260.3380.2680.169
1.331.36
0.8540.5370.5370.4260.4260.3380.2680.169
2.122.161.331.36
0.8540.5370.5370.4260.4260.3380.268
1.331.36
0.8540.5370.5370.4260.4260.3380.268
571715702865
10691713
170179254267404651640803789975
12081788
221235353570559701687847
10461676
158168235249376606595746732903
1117210224335541530664651801989
777
1919196/16/16/16/16/16/16/16/16/16/16/1
18/16/16/16/16/16/16/16/16/16/16/1
77777777777777777777
160185185215245325
70709090
120160160185185215245325
9090
120160160185185215245325
70709090
120160160185185215245
9090
120160160185185215245
AAC
ACSR
ACSRREDUCED
SIZE
AAAC
AAACREDUCED
SIZE
PURPURANASSA
TROPHONMELITA
PORTUNUSNANNYNOSE
PALUDINAVOLUTAWHELK
PERIWINKLECONCH
NERITINACENIA
RUNCINATRITONMURSIAZUZARALIMPET
SCALLOPSTROMBUS
COCKLEJANTHINARANELLA
CAVOLINIACLIOAEGA
CERAPUSCOWRYMINEXHIPPA
PRAWNBARNACLES
SHRIMPGAMMARUS
LEDADUNGENESE
CYCLOPSFLUSTRA
LEPASARTEMIA
CRABSOLASTERSANDCRABECHINUSCRAYFISH
SIPHOFULGAR
ARCA
197
19191919
171777
197
19191919
1777
197
19191919
171777
197
191919
1777
197
191919
205235235275315420
8585
115115150205205235235275315420115115150205205235235275315420
8585
115115150205205235235275315115115150205205235235275315
1/02/02/03/04/0
336.466442
1/01/02/02/03/04/0
336.46642211
1/02/04/0
30.5830.5848.6948.6977.47123.3123.3155.4155.4195.7246.9
30.630.648.777.577.597.697.6
123.3155.4
1/02/02/03/04/0
336.466442
1/01/02/02/03/04/0
336.4442
1/01/02/02/03/04/0
336.466442
1/01/02/02/03/04/0
442
1/01/02/02/03/04/0
90311381138150118232786
540540845845
12941986198624032403300037843937
540540845
1294129416161616198624033784
502502799799
1272193919392444244430773882
502502799
127212721603160319392444
Neutral Supported Triplex 600V (International System Unit)
Continued from page 40
STRANDSNo.
CODE DIAMETEROVER
INSULATION(mm)
SIZEAWG /kcmil
APPROX.TOTAL
WEIGHT(Kg/Km)
DCRESISTANCE
AT 20°C1
(ohm/Km)
STRANDINGCLASS
CROSSSECTION
(mm²)
CONDUCTORDIAMETER
(mm)
INSULATIONTHICKNESS
(mm)
AMPACITY 2
(A)3STRANDS
No. TYPE
AMPACITY 2
(A)4SIZE
AWG /kcmil
SELF SUPPORTING NEUTRAL
TENSILESTRENGTH
(Kg)
42
256272298318377486486530530580636810256272298318377486486530530580636810298318377486486530530580636810256272298318377486486530530580636298318377486
0.02060.02060.03280.03280.05210.08290.08290.10450.10450.13180.16620.26420.02060.02060.03280.03280.05210.08290.08290.10450.10450.13180.16620.26420.03280.03280.05210.08290.08290.10450.10450.13180.16620.26420.02060.02060.03280.03280.05210.08290.08290.10450.10450.13180.16620.03280.03280.05210.0829
SOLIDB
SOLIDBBBBBBBBB
SOLIDB
SOLIDBBBBBBBBB
SOLIDBBBBBBBBB
SOLIDB
SOLIDBBBBBBBB
SOLIDBBB
162178204225283361361406406456512645162178204225283361361406406456512645204225283361361406406456512645162178204225283361361406406456512204225283361
45454545456060606060608045454545456060606060608045454560606060606080454545454560606060606045454560
0.6460.6580.4060.4140.2600.1640.1640.1300.1300.103
0.08170.0514
0.6460.6580.4060.4140.2600.1640.1640.1300.1300.103
0.08170.0514
0.4060.4140.2600.1640.1640.1300.1300.103
0.08170.0514
0.6460.6580.4060.4140.2600.1640.1640.1300.1300.103
0.08170.4060.4140.2600.164
103109152161242391384481472581718
1151114120170180272438430540530655812
1202149158237383376471462569703
1126107113158168252407400501492607751141150225364
777777777
1919196/16/16/16/16/16/16/16/16/16/16/1
18/16/16/16/16/16/16/16/16/16/16/1
777777777777777
70709090
120160160185185215245325
70709090
120160160185185215245325
9090
120160160185185215245325
70709090
120160160185185215245
9090
120160
AAC
ACSR
ACSRREDUCED
SIZE
AAAC
AAACREDUCED
SIZE
HAIOTISPATELLAFUSUS
OYSTERCLAM
MUREXPURPURA
NASSATROPHON
MELITAPORTUNUS
NANNYNOSEPALUDINAVOLUTAWHELK
PERIWINKLECONCH
NERITINACENIA
RUNCINATRITONMURSIAZUZARALIMPET
SCALLOPSTROMBUS
COCKLEJANTHINARANELLA
CAVOLINIACLIOAEGA
CERAPUSCOWRYMINEXHIPPA
PRAWNBARNACLES
SHRIMPGAMMARUS
LEDADUNGENESE
CYCLOPSFLUSTRA
LEPASARTEMIA
CRABSOLASTERSANDCRAB
171777
197
19191919
171777
197
19191919
1777
197
19191919
171777
197
191919
1777
8585
115115150205205235235275315420
8585
115115150205205235235275315420115115150205205235235275315420
8585
115115150205205235235275315115115150205
66442
1/01/02/02/03/04/0
336.466442
1/01/02/02/03/04/0
336.46642211
1/02/04/0
30.5830.5848.6948.6977.47123.3123.3155.4155.4195.7246.9
30.630.648.777.5
66442
1/01/02/02/03/04/0
336.466442
1/01/02/02/03/04/0
336.4442
1/01/02/02/03/04/0
336.466442
1/01/02/02/03/04/0
442
1/0
564564882882
135119911991250925093309401961421190119018631863285343784378529852986614834286791190119018632853285335633563437852988342110711071761176128044275427553885388678485581107110717612804
Continued on page 43
Neutral Supported Triplex 600V
Manufacturing Standard: ICEA S-76-474. Neutral supported power cablesassemblies with weather resistant extruded insulation rated 600 volts.
STRANDSNo.
CODE DIAMETEROVER
INSULATION(mils)
SIZEAWG /kcmil
APPROX.TOTAL
WEIGHT(pound/1000ft)
DCRESISTANCE
AT 20°C1
(ohm/1000ft)
STRANDING(mils)
CROSSSECTION(sq inches)
CONDUCTORDIAMETER
(mils)
INSULATIONTHICKNESS
(mils)
AMPACITY 2
(A)3STRANDS
No. TYPE
AMPACITY 2
(A)4SIZE
AWG /kcmil
SELF SUPPORTING NEUTRAL
TENSILESTRENGTH
(pound)
43
486530530580636
0.08290.10450.10450.13180.1662
BBBBB
361406406456512
6060606060
0.1640.1300.1300.103
0.0817
356447437538664
77777
160185185215245
AAACREDUCED
SIZE
ECHINUSCRAYFISH
SIPHOFULGAR
ARCA
197
191919
205235235275315
77.597.697.6
123.3155.4
1/02/02/03/04/0
28043534353442755388
7.578.099.58
12.3413.4714.7416.1620.57
6.506.907.578.099.58
12.3413.4714.7416.1620.57
6.506.907.578.099.58
12.3413.4714.7416.16
21.1521.1533.6353.4867.4385.03107.2170.513.3013.3021.1521.1533.6353.4867.4385.03107.2170.513.3013.3021.1521.1533.6353.4867.4385.03107.2
SOLIDBBBBBBB
SOLIDB
SOLIDBBBBBBB
SOLIDB
SOLIDBBBBBB
5.195.717.209.18
10.3111.5813.0016.39
4.124.525.195.717.209.18
10.3111.5813.0016.39
4.124.525.195.717.209.18
10.3111.5813.00
1.141.141.141.521.521.521.522.031.141.141.141.141.141.521.521.521.522.031.141.141.141.141.141.521.521.521.52
1.331.36
0.8540.5370.4260.3380.2680.169
2.122.161.331.36
0.8540.5370.4260.3380.2680.169
2.122.161.331.36
0.8540.5370.4260.3380.268
310330494781958
117914542332
228242337358538851
1046128915932407
216230319340509806989
12171502
77777
1919196/16/16/16/16/16/16/16/16/1
18/1777777777
8080
105140160185210280
60608080
105140160185210280
60608080
105140160185210
AAC
ACSR
AAAC
CLYDESDALEPINTO
MUSTANGCRIOLLO
PERCHERONHANOVERIANOLDENBURGLIPPIZANER
MOROCHUCACHOLA
MORGANHACKNEYPALOMINOCOSTENAGRULLOSUFFOLK
APPALOOSABRONCO
BAYFRENCH-COACHGERMAN-COACH
ARABIANBELGIAN
SHETLANDTHOROUGHBRED
TROTTERWALKING
177
1919191919
17177
1919191919
17177
19191919
100100135180205235275370
7575
100100135180205235275370
7575
100100135180205235275
442
1/02/03/04/0
336.466442
1/02/03/04/0
336.430.5830.5848.6948.6977.47123.3155.4195.7246.9
442
1/02/03/04/0
336.466442
1/02/03/04/0
336.466442
1/02/03/04/0
400400613903
1138150118232786
540540845845
129419862403300037843937
502502799799
12721939244430773882
Neutral Supported Triplex 600V
Continued from page 42
STRANDSNo.
CODE DIAMETEROVER
INSULATION(mils)
SIZEAWG /kcmil
APPROX.TOTAL
WEIGHT(pound/1000ft)
DCRESISTANCE
AT 20°C1
(ohm/1000ft)
STRANDING(mils)
CROSSSECTION(sq inches)
CONDUCTORDIAMETER
(mils)
INSULATIONTHICKNESS
(mils)
AMPACITY 2
(A)3STRANDS
No. TYPE
AMPACITY 2
(A)4SIZE
AWG /kcmil
SELF SUPPORTING NEUTRAL
TENSILESTRENGTH
(pound)
Notes: 1. DC resistance calculated based on a 16,946 ohm-mm2/km resistivity for aluminum.2. 40°C Ambient temperature, 610 mm/seg wind speed, at sea level at 60 Hz.3. 75°C conductor temperature.4. 90°C conductor temperature.5. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
Neutral Supported Quadruplex 600V (International System Unit)
Manufacturing Standard: ICEA S-76-474. Neutral supported power cablesassemblies with weather resistant extruded insulation rated 600 volts.
STRANDSNo.
CODE DIAMETEROVER
INSULATION(mm)
SIZEAWG /kcmil
APPROX.TOTAL
WEIGHT(Kg/Km)
DCRESISTANCE
AT 20°C1
(ohm/Km)
STRANDINGCLASS
CROSSSECTION
(mm²)
CONDUCTORDIAMETER
(mm)
INSULATIONTHICKNESS
(mm)
AMPACITY 2
(A)3STRANDS
No. TYPE
AMPACITY 2
(A)4SIZE
AWG /kcmil
SELF SUPPORTING NEUTRAL
TENSILESTRENGTH
(Kg)
Notes: 1. DC resistance calculated based on a 28,172 ohm-mm2/km resistivity for aluminum.2. 40°C Ambient temperature, 610 mm/seg wind speed, at sea level at 60 Hz.3. 75°C conductor temperature.4. 90°C conductor temperature.5. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
44
298318377486530580636810256272298318377486530580636810256272298318377486530580636
0.03280.03280.05210.0829
0.1050.1320.1660.264
0.02060.02060.03280.03280.05210.0829
0.1050.1320.1660.264
0.02060.02060.03280.03280.05210.0829
0.1050.1320.166
SOLIDBBBBBBB
SOLIDB
SOLIDBBBBBBB
SOLIDB
SOLIDBBBBBB
204225283361406456512645162178204225283361406456512645162178204225283361406456512
454545606060608045454545456060606080454545454560606060
0.4060.4140.2600.1640.1300.103
0.08170.0514
0.6460.6580.4060.4140.2600.1640.1300.103
0.08170.0514
0.6460.6580.4060.4140.2600.1640.1300.103
0.0817
208222332525644792977
1568153162227240361572703866
10711618
145155214228342541665818
1010
77777
1919196/16/16/16/16/16/16/16/16/1
18/1777777777
8080
105140160185210280
60608080
105140160185210280
60608080
105140160185210
AAC
ACSR
AAAC
CLYDESDALEPINTO
MUSTANGCRIOLLO
PERCHERONHANOVERIANOLDENBURGLIPPIZANER
MOROCHUCACHOLA
MORGANHACKNEYPALOMINOCOSTENAGRULLOSUFFOLK
APPALOOSABRONCO
BAYFRENCH-COACHGERMAN-COACH
ARABIANBELGIAN
SHETLANDTHOROUGHBRED
TROTTERWALKING
177
1919191919
17177
1919191919
17177
19191919
100100135180205235275370
7575
100100135180205235275370
7575
100100135180205235275
442
1/02/03/04/0
336.466442
1/02/03/04/0
336.430.5830.5848.6948.6977.47123.3155.4195.7246.9
442
1/02/03/04/0
336.466442
1/02/03/04/0
336.466442
1/02/03/04/0
882882
1351199125093309401961421190119018631863285343785298661483428679110711071761176128044275538867848558
Notes: 1. DC resistance calculated based on a 16,946 ohm-mm2/km resistivity for aluminum.2. 40°C Ambient temperature, 610 mm/seg wind speed, at sea level at 60 Hz.3. 75°C conductor temperature.4. 90°C conductor temperature.5. Data herein indicated are approximated and are subject to normal manuracturing tolerances.
Neutral Supported Quadruplex 600V
Manufacturing Standard: ICEA S-76-474. Neutral supported power cablesassemblies with weather resistant extruded insulation rated 600 volts.
STRANDSNo.
CODE DIAMETEROVER
INSULATION(mils)
SIZEAWG /kcmil
APPROX.TOTAL
WEIGHT(pound/1000ft)
DCRESISTANCE
AT 20°C1
(ohm/1000ft)
STRANDING(mils)
CROSSSECTION(sq inches)
CONDUCTORDIAMETER
(mils)
INSULATIONTHICKNESS
(mils)
AMPACITY 2
(A)3STRANDS
No. TYPE
AMPACITY 2
(A)4SIZE
AWG /kcmil
SELF SUPPORTING NEUTRAL
TENSILESTRENGTH
(pound)