Low Voltage Cable RangeEdition 4 Brochure
Revised 07/ 2010
C O M P A N Y P R O F I L EAberdare Cables, a member of the Powertech Group, is a leading African manufacturer ofcables with five manufacturing sites, in three provinces of South Africa, and offshoreoperations in Mozambique, Portugal and Spain. The company's customer base includespower supply authorities, railway and transport organisations, municipalities, andcompanies in industries such as petrochemical, mining, wholesale, industrial, constructionand domestic building.The company manufactures and sells a wide range of state of the artproducts with customer specific adaptation, design capabilities and full technical back-upservice. Aberdare Cables prides itself on its ability to identify and satisfy customer needsthrough development of innovative products; unique, cost effective cable solutions for a widerange of industries. This and their extensive project experience make them the supplier ofchoice for cable, related accessories and special cable projects.
Aberdare Cables pursues ongoing technology development programmes, and throughactive association with its local and overseas affiliates, continues to remain at the forefront oftechnology. The company has been recognised internationally as a pioneer in cableadvancements. Aberdare serves on a number of SABS and International ElectrotechnicalCommission (IEC) cable working groups. As much as ten years ago, in a move towardsfacilitating the provision of electricity for all countrywide,Aberdare Cables designed productswith an emphasis on cost efficiency of electrification. To this end, Aberdare created itsElectrodac range, which is aimed specifically at facilitating rural electrification by lowering thecost of electricity delivery. More recently, in accordance with Siemens specifications,Aberdare produced an unarmoured cable, with stringent fire characteristics, that wasdesigned to reduce the propagation of fire by cables.This cable is used at Eskom's open-cyclegas turbine generators at Mossel Bay and Atlantis. To cater for international markets,Aberdare introduced fire survival cable with stringent properties that allow continuousoperation and circuit integrity for extended periods during a fire.
Aberdare Cables is a fore runner in the industry with regard to quality.The manufacturing,quality assurance, testing and research resources of Aberdare are of a world-class standard.In fact, the company was one of the first companies in South Africa to be awarded the SouthAfrican Bureau of Standards (SABS) Quality Assurance Certification, and has been ISO 9001compliant for many years.Aberdare Cables is UL listed and has Basec QA accreditation.
Aberdare Cables has embraced the empowerment concept.Today Aberdare enjoys a strongand active relationship with Izingwe Consortium, their empowerment partner. AberdareCables employs a strategic focus on skills development and employment equity. Thecompany has always been an active supporter and pillar of strength for the communities inwhich it operates, championing a number of social investment initiatives across our country.The company has also assisted in the development of a number of black enterprises and willcontinue to drive such initiatives.
As a proudly South African company, Aberdare participated actively in the development ofthe ICT charter and the draft DTI BBBEE codes. Aberdare will continue to adopt a proactiveapproach to effect the transformation that the codes specify and to lead the cable industry inthis regard.
Aberdare, cable you can trust
General Wires
Slipdac Single Core Cable
Single Core PVC 1kV Cable
Single Core PVC 3,3kV Cable
Single Core PVC PVC Cable
Single Core XLPE PVC Cable
Surfix Cable
Flat Twin and Earth Cable
Cabtyre Cable
Audio Cord Cable (Ripcord)
Submersible Pump Cable
General Welding Cable
PVC Nitrile Cable
Nitrile Trailing Cable
Monster Cable
HQR Insulated Cable
Illumination Cable
Panel Flex Cable
Power Panel Flex Cable
Bare Copper Wire
Bells & Mains Cable
Multicore Cable
Single Core Cable
Interdac 3 CableAirdac SNE Cable
Airdac II CNE Cable
Aerial Bundle Conductor (ABC) Cable
Silicone Cabtyre Cable
Silicone Single Cable
Special Silicone Cable
Abbreviations Applicable To Cable Descriptions
Useful Technical Data
General
Bare Copper
Low Voltage Armoured Cables
Electrodac
Silicone
1
2
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
22
24
25
27
2930
31
32
34
35
36
38
39
21
23
28
33
37
ContentsLow voltage Brochure
Please note that it is mandatory that the selection and installation of our products, be carried out incompliance with SANS 10142, Part 1 Code of Practice, "TheWiring of Premises".
General Wires
1
Slipdac Single Core®
Low Friction General Purpose Cable
Cable Description
SLIPDAC
Installation Information
SLIPDAC
Properties
High conductivity annealed stranded copper conductors to SANS 1411 Part 1. Insulated with PVC and skin coloured in plain coloursto SANS 1411 Part 2. Cable is manufactured to SANS 1507 Part 2. is the Aberdare Power Cables trade name for a newlydeveloped range of General Purpose wires with superior low friction characteristics.
For the wiring of Industrial Buildings, Housing, Control Panels, where will be easier to pull through conduit, thanstandard housewire particularly on long and difficult runs.
SANS 1507-2-10°C to 70°C600 / 1000VComplete range of colours100m shrink-wrapped perforated coils / 500m reels
A specially developed low friction PVC compound which is used in the insulation of House wire for supply to the South Africanmarket.
®
®
Specification :Temperature Range :Voltage Rating :Core Identification :Packaging :
* Note:
** Note:
- Rating based on two touching cables, installed in a duct.- Assumed ambient air temperature is 30°C.- Assumed maximum conductor temperature is 70°C.- Compacted Conductors
Technical Data
CableSize
ConductorResistance
@ 20°CMaximum
CurrentRating
*
Approx.Overall
Diameter
Approx.Cable
Mass per100m Coil
NominalStranding
No. x diameter
(mm²) (A) (mV/A/m)(mm) (kg)
1VoltDrop
�
( /km)�
600 / 1000 V
1,72,23,25,27,0
11,116,7
432918117,44,42,8
3,03,33,64,55,06,06,9
17212736456178
18,112,17,414,613,081,831,15
7/0,427/0,53
7/0,66**7/0,86**7/1,04**7/1,35**7/1,67**
11,52,5461016
2
ABERDARE CABLES
SLIPDAC
SLIPDAC
has established
a procedure for testing of the pulling
force required to pull a sample of cable
through a preformed length of standard
20mm SABS conduit. The initial force
required to move the cable was
measured and recorded for a number
of samples of different sizes in the
house wire range of colours, for both
standard products as well as for
See attached photograph of the
rig used during testing. (The
conduit was exchanged for an unused
piece from the same batch, at regular
intervals).
®
®
Slipdac Single Core®
Low Friction General Purpose Cable
3
What are the benefits of this product solution compared to standard housewire?
• The pulling force required to pull the product throughconduit, is significantly reduced, as the cable-to-conduitand cable to cable friction is lower than on the standardproduct.
• The product is neatly and accurately coiled on automaticcoilers, which reduces the risk of entanglement.
• The coils are sized for placement in a standardbucket where they may be stored securely
after use. Refer PHOTO 3.
• The heat-shrunk plastic used in the packaging, keeps the
coil in a sturdy, compact form until such time as it is used,thus there is a reduced risk of entanglement due to poorhandling.
• The perforated packaging allows for easy access to the wireend on the inside of the coil, without having to disturb thepackaging or the body of the coil during use. Refer PHOTO 1.
• The packaging is perforated on both the top and bottom, thusallowing coils to be stacked for simultaneous extraction of allrequired colours. A useful tool for this purpose is a bucket,which will hold the stacked coils in place while the wire isbeing withdrawn. Refer PHOTO 2.
SLIPDAC
SLIPDAC
®
®
The following benefits are relevant:
Photo 1:
The SLIPDAC coil - Notethe perforation marks in the
centre part of the coil.
®Photo 3:
The bucket lid is replacedwith partially used coils
remaining in the bucket forfuture use.
Photo 2:
Extraction of 3 or 4 wiressimultaneously from coils
held
Cable Description
Installation Information
Properties
High conductivity annealed stranded or solid copper conductors to SANS 1411 Part 1. Insulated with general purpose grade PVC inplain colours to SANS 1411 Part 2.
For the wiring of :• Industrial Buildings • Control Panels
SANS 1507-3-10°C to 70°C600 / 1000VBlue, Black,Yellow/Green,White, Red100m shrink-wrapped coils up to 70mm²Over 70mm² on 300m drums
Specification :Temperature Range :Voltage Rating :Core Identification :Packaging :
:
Single Core PVC 1kV CableGeneral Purpose Wire (Housewire)
* Note:
** Note:
- Rating calculated for 1kV cable.- Rating based on two touching cables installed in a duct.- Assumed ambient air temperature is 30°C.- Assumed maximum conductor temperature is 70°C.- Compacted Conductors
Technical Data
CableSize
ConductorResistance
@ 20°CMaximum
CurrentRating
*
Approx.Overall
Diameter
Approx.Cable
Mass per100m Coil
NominalStranding
No. x diameter
(mm²) (A) (mV/A/m)(mm) (kg)
1VoltDrop
�
( /km)�
2535507095120150185240300400500630
19/1,38**19/1,62**19/1,88**19/2,28**19/2,5037/2,0337/2,2837/2,5061/2,2861/2,5061/2,8061/3,1591/2,93
8,49,511,312,615,817,519,722,025,027,531,034,538,0
104125149190238272308350408463531610696
0,730,520,390,270,190,150,120,100,080,060,050,040,03
1,71,30,930,650,480,380,320,260,210,180,160,140,13
25,634,747,266,197,6
120,0147,0182,2235,0298,0379,0483,1622,5
4
Cable Description
Installation Information
Properties
High conductivity annealed stranded or solid copper conductors to SANS 1411 Part 1. Insulated with general purpose grade PVC inplain colours to SANS 1411 Part 2.
For the wiring of :• Industrial Buildings • Control Panels
SANS 1507-3-10°C to 70°C1,9/3,3 kVBlue, Black,Yellow/Green,White, Red100m shrink-wrapped coils up to 70mm²Over 70mm² on 300m drums
Specification :Temperature Range :Voltage Rating :Core Identification :Packaging :
:
Single Core PVC 3,3kV CableGeneral Purpose Wire (Housewire)
* Note:
** Note:
- Rating calculated for 3,3kV cable.- Rating based on two touching cables installed in a duct.- Assumed ambient air temperature is 30°C.- Assumed maximum conductor temperature is 70°C.- Compacted Conductors
Technical Data
CableSize
ConductorResistance
@ 20°CMaximum
CurrentRating
*
Approx.Overall
Diameter
Approx.Cable
Mass per100m Coil
NominalStranding
No. x diameter
(mm²) (A) (mV/A/m)(mm) (kg)
1VoltDrop
�
( /km)�
2535507095120150185240300400500630
19/1,38**19/1,62**19/1,88**19/2,28**19/2,5037/2,0337/2,2837/2,5061/2,2861/2,5061/2,8061/3,1591/2,93
10,411,512,914,217,018,720,522,425,027,531,034,938,0
104125149190238272308350408463531610696
0,730,520,390,270,190,150,120,100,080,060,050,040,03
1,71,30,930,650,480,380,320,260,210,180,160,140,13
25,634,747,266,197,6
120,0147,0182,2235,0298,0379,0483,1622,5
5
Technical Data
2535507095120150185240300400500630
5,957,008,159,7911,5412,9614,3916,1018,7121,4524,3026,5133,15
11,9112,9615,1516,5719,0420,2422,0724,8027,8130,7534,1037,1343,62
366469632880116014131734214527253375439552996965
0,87670,63560,47450,33560,25000,20540,17340,14990,12680,11310,10280,09630,0890
118156186232281324370424498566651740836
133165203251313362414482578660704821960
1,71,30,90,70,50,40,30,30,20,20,20,20,2
127153180221265301338381442499565634718
91109130166208237267305357404442506580
109136171214271316366433525604639752886
1,501,100,800,600,400,300,300,200,200,200,200,200,10
RatedArea
NominalDiameters
NominalMass
Cables A.C. or D.C. Cables inTrefoil Formation
Impe-dance Current Rating
*Current Rating
GroundD1(mm²) (kg/km)D2 ( /km)� Ground Duct AirAir (mV) (mV)
Voltage Dropper Amp
per metre
Voltage Dropper Amp
per metre
PVC Current Ratings are Based on the following Environmental Parameters
Maximum SustainedConductor
Temperature
GroundTemperature
Ambient AirTemperature
Depth of Layingto top of Cable
GroundThermalResistivity
70 Co 25 Co 30 Co 1,2 K.m/W 500mm
Single Core PVC PVC CableGeneral Purpose Wire
Cable Description
Installation Information
Properties
High conductivity annealed stranded or solid copper conductors to SANS 1411 Part 1. Insulated with general purpose grade PVC inplain colours to SANS 1411 Part 2.
For the wiring of :• Industrial Buildings • Control Panels
SANS 1507-3-10°C to 70°C600 / 1000VBlack300/500m Drums
Electrical and physical properties of single core PVC Insulated cables with stranded copper conductors, unarmoured, PVCsheathed 600 / 1000V manufactured to SANS 1507-3.
Specification :Temperature Range :Voltage Rating :Core Identification :Packaging :
6
* Note: - Rating based on two touching cables installed in a duct.- Assumed ambient air temperature is 30°C.- Assumed maximum conductor temperature is 70°C.
Cable Description
Installation Information
Properties
High conductivity annealed stranded or solid copper conductors to SANS 1411 Part 1. Insulated with XLPE plain colours to SANS1411 Part 4.
For the wiring of :• Industrial Buildings • Control Panels
SANS 1507-4-10°C to 90°C600/1000VBlack300/500m Drums
Specification :Temperature Range :Voltage Rating :Core Identification :Packaging :
Single Core XLPE PVC CableGeneral Purpose Wire (600/1000V)
7
Technical Data
2535507095120150185240300400500630
5,957,008,159,7911,5412,9614,3916,1018,7121,4524,3026,5133,15
11,8112,8614,3816,2217,9719,8221,4223,6326,6930,0533,3036,3342,79
328426567824107113041628199524613182411750326641
0,87670,63560,47450,33560,25000,20540,17340,14990,12680,11310,10280,09630,0890
16920524530236642248055465676690210401229
16220225531338044150858570480487410131205
2,01,41,00,70,50,40,40,30,20,20,20,20,2
151181213260312355397449522589668750848
103125154192233268305345406459511583680
1431792292843464024655376487418059351115
1,71,20,90,60,50,40,30,30,20,20,20,20,2
RatedArea
NominalDiameters
NominalMass
Cables A.C. or D.C. Cables inTrefoil Formation
Impe-dance Current Rating
*Current Rating
GroundD1(mm²) (kg/km)D2 ( /km)� Ground Duct AirAir (mV) (mV)
Voltage Dropper Amp
per metre
Voltage Dropper Amp
per metre
PVC Current Ratings are Based on the following Environmental Parameters
Maximum SustainedConductor
Temperature
GroundTemperature
Ambient AirTemperature
Depth of Layingto top of Cable
GroundThermalResistivity
90 Co 25 Co 30 Co 1,2 K.m/W 500mm
* Note: - Rating for two touching cables installed in air.- Assumed ambient air temperature is 30°C.- Assumed maximum conductor temperature is 90°C.
Cable Description
Installation Information
Properties
Copper conductors to SANS 1411 Part 1, PVC insulated to SANS 1411 Part 2 , laid up with a bare tinned copper earth wire in contactwith a longitudinal aluminium/polyethylene laminate, UV stable PVC sheathed to SANS 1411 Part 2.
Complies with SANS 10142 “Code of Practice for wiring of Premises” Section 6:• Surface wiring • Under-plastering wiring • Wiring in hollow walls • Wiring in roof spaces
The cable shall not be buried direct in concrete or in screed. Joints in the wiring shall be in boxes only.
SANS 1507-2-10°C to 70°C300 / 500VWhite & Black
- Red & Black, - Red,Yellow, Blue, - Red,Yellow, Blue, Black100m shrink-wrapped coilsAvailable on 500 & 1000 metre wooden drums on request (depending on size)
Note:
Specification :Temperature Range :Voltage Rating :Sheath Identification :Core Identification : 2 Core 3 Core 4 CorePackaging :
:
Surfix Cable
Note: * Conductors larger than 2,5mm² are usually stranded.** Maximum conductor temperature 70° C*** 2 Core - Volt drop is phase to Neutral (ie. Single-phase).
3 and 4 Core - Volt drop is phase-to-phase. (ie. Three phase AC).
, and installed as per installation Method 3 of SANS 10142-1.
Technical Data
CableSize
*
ConductorResistance(dc @ 20°C)
CurrentRating
**
1 Sec ShortCircuitRating
Approx.CableMass
Approx.Overall
Diameter
Phase PhaseEarth Earth
VoltDrop***
(mm²) (mm)(mV/A/m)(mV/A/m)(A) (kA) (kg/100m)( /km)�
Electrical Properties Physical Properties
2 Core
3 Core
4 Core
1,52,546
1,52,546
1,52,546
11,51,52,5
11,51,52,5
11,51,52,5
12,17,414,613,08
12,17,414,613,08
12,17,414,613,08
18,212,212,27,56
18,212,212,27,56
18,212,212,27,56
17233038
15202734
15202734
2918117,3
25159,56,4
25159,56,4
0,140,240,380,58
0,140,240,380,58
0,140,240,380,58
7,88,810,111,3
8,09,310,812,0
8,710,211,812,8
10,614,420,825,7
10,915,721,028,7
13,319,326,533,5
8
Cable Description
Installation Information
Properties
Copper conductors to SANS 1411 Part 1, PVC insulated to SANS 1411 Part 2, laid up with a bare copper earth-continuity-conductorbetween them, UV stable PVC sheathed to SANS 1411 Part 2.
Complies with SANS 10142/2001“Code of Practice for the wiring of Premises” Section 6, Clause 6.3.6:• Surface wiring • Under-plaster wiring • Roof access wiring • Wiring in hollow walls
The cable shall not be buried direct in concrete or in screed. Joints in the wiring shall be in boxes only.
SANS 1507-2-10°C to 70°C300 / 500VWhite & Black
- Red & Black, - Red,Yellow, Blue100m shrink-wrapped coils
Note:
Specification :Temperature Range :Voltage Rating :Sheath Identification :Core Identification : 2 Core 3 CorePackaging :
FlatTwin and Earth Cable
Note: * Conductors larger than 2,5mm² are usually stranded.** Maximum conductor temperature 70° C, and installed as per installation Method 3 of SANS 10142-1.*** 2 Core - Volt drop is phase to Neutral (ie. Single-phase).
3 and 4 Core - Volt drop is phase-to-phase. (ie. Three phase AC).
Technical Data
CableSize
*
ConductorResistance(dc @ 20°C)
CurrentRating
**
1 Sec ShortCircuitRating
Approx.CableMass
Approx.Overall
Diameter
Phase PhaseEarth Earth
VoltDrop***
(mm²) (mm)(mV/A/m)(mV/A/m)(A) (kA) (kg/100m)( /km)�
Electrical Properties Physical Properties
2 Core
3 Core (Trip)
1,52,54610
11,52,5
11,51,52,54
11
1,5
12,17,4
4,613,081,83
18,212,17,4
18,112,112,17,414,61
18,218,212,2
1723303852
121520
2918117,34,4
382515
0,140,240,380,580,96
0,110,140,24
8,7 x 4,710,3 x 5,511,9 x 6,413,4 x 7,016,5 x 8,3
4,4 x 10,44,8 x 10,55,5 x 12,3
8,712,817,523,336,1
8,99,914,1
9
Cabtyre CableFlexible Wiring
* Note: Current Rating based on - Ambient temperature is 30ºC Maximum Conductor temperature is 70°C
Cable Description
Installation Information
Properties
High conductivity bunched plain flexible copper conductors to SANS 1411 Part 1. Insulated and colour coded with general purposeflexible grade PVC to SANS 1411 Part 2. Cores are twisted together and sheathed with a flexible grade PVC.
For supplying power to all types of electrical, domestic and industrial appliances and equipment such as:• PowerTools • Electric Lawnmowers • Kitchen Appliances• Extension Leads • Multi Plug Extensions • Small Industrial Machinery
SANS 1574-10°C to 70°CLight Duty (LD) 300 / 300V and Normal Duty (ND) 300 / 500V
- Blue & Brown, - Blue, Brown & Yellow/Green, - Blue, Brown, Black &Yellow/Green, - Blue, Black, Brown, Yellow/Green, Violet, - Blue, Brown, Black,Yellow/Green,Violet, Pink, OrangeWhite, Black, Grey100m shrink-wrapped coils / 500m & 1000m lengths available on request
Specification :Temperature Range :Voltage Rating :Core Identification : 2 Core 3 Core 4 Core
5 Core 7 Core
Sheath Colours :Packaging :
Technical Data
CableSize
ConductorResistance
@ 20°CMaximum
CurrentRating
*
Approx.Overall
Diameter
Approx.Cable
Mass per100m Coil
NominalStranding
No. x diameter
(mm²) (A) (mV/A/m)(mm) (kg)
VoltDrop
( /km)�
Numberof
Cores 1� 1�3� 3�
Light Duty 300 / 300V
Normal Duty 300 / 500V
23453
234572345723457234572345
5,25,56,06,66,1
6,27,07,28,28,76,67,08,08,69,37,88,39,310,010,99,610,311,912,213,211,011,413,514,1
33336
6666610101010101616161616252525252532323232
33336
6666610101010101616161616202020202025252525
9393939362
626262626246464646463232323232191919191912121212
8080808054
545454545440404040402727272727161616161610101010
3,94,75,56,75,5
5,26,77,89,912,66,37,69,811,614,88,410,813,516,220,713,516,821,824,231,319,025,032,033,9
0,5
0,75
0,75
1
1,5
2,5
4
15/0,2
23/0,2
23/0,2
30/0,2
44/0,2
72/0,2
112/0,2
39
26
26
19,5
13,3
7,98
4,96
10
* Note: - Assumed ambient air temperature is 30°C.- Assumed maximum conductor temperature is 70°C.
Audio Cord Cable (Ripcord)Flexible Wiring
Cable Description
Installation Information
Properties
High conductivity bunched plain flexible copper conductors to SANS 1411 Part 1. 2 Core insulated with general purpose flexiblegrade PVC to SANS 1411 Part 2.
For the wiring of all types of:• Intercoms • Alarm Systems• Solar Industry • Audio andVisual Equipment
ABERDARE Specification-10°C to 70°CStandard Colours -White, Brown, Grey, Black,Transparent and Red with Black StripeOther Colours available on request100m shrink-wrapped coils / 500m lengths available on request
Specification :Temperature Range :Core Identification :
:Packaging :
Technical Data
CableSize
ConductorResistance
@ 20°CMaximum
CurrentRating
*
Approx.Overall
Diameter
Approx.Cable
Mass per100m Coil
NominalStranding
No. x diameter
(mm²) (A) (mV/A/m)(mm) (kg)
1VoltDrop
�
( /km)�
0,20,40,50,751,001,52,54
7/0,211/0,215/0,223/0,230/0,244/0,272/0,2112/0,2
1,6 x 3,22,1 x 4,22,5 x 5,02,7 x 5,42,9 x 5,83,2 x 6,43,9 x 7,94,7 x 9,4
123610162532
9248,83926
19,513,37,984,96
24898936246321912
0,951,62,22,83,64,36,910,9
11
Submersible Pump Cable3 and 4 Core
Cable Description
Installation Information
Properties
High conductivity bunch plain flexible copper conductors to SANS 1411 Part 1.. Cores insulated and bedded with Flexible PVCGrade. Final protection is given by a flexible PVC outer sheath.
Power supply of mobile and portable submersible pumps as used in:• Quarries • Farms • Cleaning and Sewerage extraction plants• De-watering • Boreholes
SANS 1574-10°C to 70°CFlexible grade waterproof PVC600 / 1000V
- Blue, - Green- Red,Yellow, Blue, - Red,Yellow, Blue, Black
Available on 500 metre wooden drums
Specification :Temperature Range :Insulation & Sheath :Voltage Rating :Sheath Identification : 3 Core 4 CoreCore Identification : 3 Core 4 CorePackaging :
* Note: - Assumed ambient air temperature is 30°C.- Assumed maximum conductor temperature is 70°C.
Technical Data
CableSize
ConductorResistance
@ 20°CMaximum
CurrentRating
*
Approx.Overall
Diameter
Approx.Cable
Mass per100m Coil
MinimumBendingRadius
(mm²) (A) (mV/A/m)(mm) (kg)
VoltDrop
( /km)�
1,5 x 32,5 x 34 x 36 x 310 x 316 x 3
1,5 x 42,5 x 44 x 46 x 410 x 416 x 4
8294108121141161
89102116132153176
0,150,20,30,50,60,8
0,20,250,350,50,71
152030355065
152030355065
13,37,984,963,301,911,21
13,37,984,963,301,911,21
2917127,34,32,8
2917127,34,32,8
25159,56,43,82,4
25159,56,43,82,4
10,211,713,515,117,620,1
11,212,814,616,519,222,0
3 Core (Blue)
4 Core (Green)
1220V
� 3380V
�
12
* Note:
Ambient temperature, ºC
Rating factor, X
- Assumed ambient air temperature is 30°C.- Assumed maximum conductor temperature is 85°C.- Assumed duty cycle period 5 minutes.- Derating of maximum current for other ambient temperatures - use rating factor X as given below:
: 25 30 35 40 45: 1,04 1,00 0,95 0,91 0,85
General Welding CableEPM/CM or EPM/CR
Cable Description
Installation Information
Properties
Single core flexible copper conductors to SANS 1411 Part 1, EPM (Ethylene-propylene monomer) insulated, CM (ChloronatedPolyethylene) or CR (Polychloropene) sheathed, heavy duty welding cables.
Heavy duty welding for:• Indoor and outdoor electric welding equipment.
SANS 1576100V ac or dc to earth for welding applicationsEPM/CM - Outer CM sheath is colouredEPM/CR - EPM insulation is coloured and CR sheath is black100m shrink-wrapped coils
Specification :Voltage Rating :Core Identification :
:Packaging :
ColourCode
ConductorSize
MaximumDiameterof Wires
NominalThickness
ofInsulation
Approx.CableMass
Approx.Overall
Diameter
Approx.Diameter
MaximumResistanceof UntinnedConductor
at 20°C
Technical Data
(mm²) (mm)(mm)(mm)(mm) (kg/m)( /km)�
Conductor Dimensions
GreenBlueGreyRed
BrownYellowBlack
162535507095120
0,310,310,310,310,310,310,51
5,27,18,510,411,614,115,6
1,2100,7800,5540,3860,2720,2060,161
2,02,02,02,22,42,62,8
9,211,112,514,816,419,321,2
0,250,350,450,600,751,101,40
Physical Properties
Automatic ManualConductor
Size
Maximum Current Rating (A) for Duty Cycles of:
D.C.Voltage
Drop
VeryIntermittent
Semi-automatic
(mm²) 20%30%85%100% mV/A/m60%
Class of Welding
Electrical Properties
162535507095120
131177220280346422493
134182229293364446523
142197252327411508599
172246322426546681809
199289380507654819976
1,61,00,80,60,50,40,3
13
PVC Nitrile CablePanelling/Welding
Cable Description
Installation Information
Properties
Single core flexible copper conductors to SANS 1411 Part 1, insulated with general purpose flexible grade PVC and sheathed witha flexible grade waterproof PVC/Nitrile.
A flexible power cable where flexibility is needed in equipment such as:• LVTransformer Connections
SANS 1574 Part 3-10°C to 70°C600 / 1000VRed, Black, Blue,Yellow (Other colours on request)Shrink-wrapped coils from 16mm² to 70mm² or 500m drumsThe product is sequentially marked at one metre intervals
• Motor Control Centres• GeneralWiring Applications • Distribution Boards
Specification :Temperature Range :Voltage Rating :Core Identification :Packaging :
:
14
ConductorSize
Approx.ConductorDiameter
Approx.CableMass
Approx.Cable
Diameter
Impedanceat 70°C
ApproximateVolt Drop
ContinuousCurrent Rating
*
(mm²) 3� 3�1� 1�(mm)
(mV/A/m) (A)
(kg/100m)(mm) ( /km)�
162535507095120150185
5,27,18,510,411,614,115,617,3020,00
10,813,515,318,421,224,125,627,730,8
1,4600,9330,6630,4620,3260,2470,1930,160,14
2,81,71,30,90,70,50,40,30,3
2,41,51,10,80,60,40,40,30,3
76104125148187232265299343
6488106126159198226255292
23,0031,5042,5057,5076,00101,00129,00159,00189,00
Technical Data
* Note:
Ambient temperature, ºC
Rating factor, X
Fault rating
- Current ratings are based on cable installed in a cubicle, and may vary depending on other applications.- Assumed ambient air temperature is 30°C.- Maximum conductor temperature is 70°C.- Derating of maximum current for other ambient temperatures - use rating factor X as given below:
: 25 30 35 40 45: 1,04 1,00 0,95 0,91 0,85: 115A/mm² (1 Second)
* Note: - Assumed ambient air temperature is 30°C.- Assumed maximum conductor temperature is 70°C.
Cable Description
Installation Information
Properties
High conductivity bunch plain flexible copper conductors to SANS 1411 Part 1. Cores insulated and bedded with Flexible PVC.Flexible Grade PVC / Nitrile outer sheath.
• Power supply of mobile and stationary industrial machinery• Applications that require medium duty abrasion and where oil and water resistance is required.
Good chemical resistance. Flame retardant, self extinguishing. Oil and water resistant.
SANS 1574-10°C to 70°C600 / 1000VPVC / Nitrile - OrangeRed,Yellow, Blue, BlackAvailable on 500 metre wooden drums
Specification :Temperature Range :Voltage Rating :Sheath Identification :Core Identification :Packaging :
NitrileTrailing CableFlexible PVC - 4 Core
Technical Data
CableSize
ConductorResistance
@ 20°CMaximum
CurrentRating
*
Approx.Overall
Diameter
Approx.CableMass
(mm²) (A) (mV/A/m)(mm) (kg/m)
1VoltDrop
�
( /km)�
1,5 x 42,5 x 44 x 46 x 410 x 416 x 425 x 4
13,37,984,963,301,911,210,78
15203035506595
25159,56,43,82,40,87
111315172023
26,2
0,20,30,40,50,71
1,4
15
* Note: - Assumed ambient air temperature is 30°C.- Assumed maximum conductor temperature is 70°C.
Monster CableFlexible Wiring
Cable Description
Installation Information
Properties
High conductivity bunched plain flexible copper conductors to SANS 1411 Part 1. 2 Core insulated with general purpose flexiblegrade PVC to SANS 1411 Part 2.
For the wiring of:• Audio (Loud Speaker Leads)Equipment • Solar Power Industry
ABERDARE Specification-10°C to 70°CTransparent with Blue Stripe100m shrink-wrapped coils or 100m reels
Specification :Temperature Range :Core Identification :Packaging :
1,001,63,0
30/0,251/0,290/0,2
2,9 x 5,84,1 x 8,25,5 x 11
101629
19,5116,5
463316
3,66,310,2
CableSize
ConductorResistance
@ 20°CMaximum
CurrentRating
*
Approx.Overall
Diameter
Approx.Cable
Mass per100m Coil
NominalStranding
No. x diameter
(mm²) (A) (mV/A/m)(mm) (kg)
1VoltDrop
�
( /km)�
Technical Data
16
HQR Insulated CableHighTemperature Insulated Wire 105°C
Cable Description
Installation Information
Properties
High conductivity solid copper conductor to SANS 1411 Part 1. Insulated with D5 High temperature PVC 105°C to SANS 1411Part 2.
For the wiring of:• Capacitor Tails • Ballasts for Fluorescent Lights
SANS 1507-2-10°C to 105°C300 / 500VWhite, Yellow, Black, Brown, Red, Orange, Tan, Light Blue and White with a choice of either Yellow,Orange, Red, Black, Blue or Brown Stripes7000m lengths down coiled into cardboard barrels
Specification :Temperature Range :Voltage Rating :Core Identification :
Packaging :
* Note: - Rating based on two touching cables installed in a duct.- Assumed ambient air temperature is 30°C.- Assumed maximum conductor temperature is 105°C.
Technical Data
CableSize
ConductorResistance
@ 20°CMaximum
CurrentRating
*
Approx.Overall
Diameter
Approx.Cable
Mass per100m Coil
NominalStranding
No. x diameter
(mm²) (A) (mV/A/m)(mm) (kg)
1VoltDrop
�
( /km)�
0,5 1 x 0,8 2,6 15 36 96,1 1,1
17
* Note: - Assumed ambient air temperature is 30°C.- Assumed maximum conductor temperature is 70°C.
Cable Description
Installation Information
Properties
High conductivity stranded plain copper conductors. Insulated and sheathed with general purpose flexible grade PVC in a flatparallel configuration.
• For festoon lighting at festivals, parties, outdoor functions• Other applications where quick fit lamp holders are used or required
The correct size profile and soft sheath allows for a watertight seal between the standard lamp holder and the cable.
SANS 1507 AFAA-10°C to 70°C300 / 500VBlack or RedBlack and Red100m shrink-wrapped coils1000m drums available on request
Specification :Temperature Range :Voltage Rating :Sheath Colour :Core Identification :Packaging :
:
Illumination CableFlexible Wiring (also called Maconite)
Technical Data
CableSize
ConductorResistance
@ 20°C
CurrentRating
*
Approx.Overall
Diameter
Approx.Cable
Mass per100m Coil
Numberof
Cores
(mm²) (A) (mV/A/m)(mm) (kg)
1VoltDrop
f
( /km)W
2,5 2 7,98 25 15 10,2 x 5,6 12
18
Panel Flex CableSingle Core Flexible Wiring
Cable Description
Installation Information
Properties
High conductivity bunched plain flexible copper conductors to SANS 1411 Part 1. Insulated with general purpose flexible gradePVC in all colours to SANS 1411 Part 2.
For the wiring of all types of:• Control panels • Light fittings • Communication panels • Appliances
SANS 1574-3-10°C to 70°C300 / 500V and 600 / 1000VBlue, Black, Brown,Yellow/Green, Orange, Pink,Violet, Grey,White, Red100m shrink-wrapped coils500m lengths available on request2500m, 4000m and 7000m lengths down coiled into cardboard barrels available on request.(depending on size)
Specification :Temperature Range :Voltage Rating :Core Identification :Packaging :
::
* Note: - Assumed ambient air temperature is 30°C.- Assumed maximum conductor temperature is 70°C.- Rating for 2 wires only
Technical Data
600 / 1000V
0,50,75
11,52,54610162535
15/0,223/0,230/0,244/0,272/0,2112/0,2175/0,2294/0,2462/0,2721/0,211026/0,21
2,62,83,03,33,74,85,39,110,012,714,5
111416202635435875100122
3926
19,513,37,984,953,301,911,210,7800,55
93,362,246,731,819,111,87,94,62,91,91,3
1,11,31,62,23,14,97,3
11,116,727,135,8
CableSize
ConductorResistance
@ 20°CMaximum
CurrentRating
*
Approx.Overall
Diameter
Approx.Cable
Mass per100m Coil
NominalStranding
No. x diameter
(mm²) (A) (mV/A/m)(mm) (kg)
1VoltDrop
f
( /km)W
19
Power Panel Flex Cable
Cable Description
Installation Information
Properties
Single core flexible copper conductors to SANS 1411 Part 1, insulated with general purpose flexible grade PVC and sheathed witha flexible grade waterproof PVC/Nitrile
A flexible power cable where flexibility is needed in equipment such as:• LV transformer connections • Motor control centres• General wiring applications • Distribution boards
SANS 1574 Part 3-10°C to 70°C600 / 1000VRed, Black, Blue,Yellow (Other colours on request)Shrink-wrapped coils from 16mm² to 70mm² or 500m drumsThe product is sequentially marked at one metre intervals.
Specification :Temperature Range :Voltage Rating :Core Identification :Packaging :
:
* Note:
Ambient temperature, ºC
Rating factor, X
Fault rating
- Current ratings are based on cable installed in a cubicle, and may vary depending on other applications.- Assumed ambient air temperature is 30°C.- Maximum conductor temperature is 70°C.- Derating of maximum current for other ambient temperatures - use rating factor X as given below:
: 25 30 35 40 45: 1,04 1,00 0,95 0,91 0,85: 115A/mm² (1 Second)
Technical Data
ConductorSize
Approx.ConductorDiameter
Impedanceat 70°C
ContinuousCurrent Rating *
Approx.CableMass
Approx.Cable
Diameter
Approx.Volt Drop
(mm²) (mm) (mm)
(mV/A/m) (A)
(kg/100m)( /km)W 1f 1f3f 3f
162535507095120150185
5,27,18,510,411,614,115,617,3020,00
10,813,515,318,421,224,125,627,730,8
1,4600,9330,6630,4620,3260,2470,1930,160,14
2,81,71,30,90,70,50,40,30,3
2,41,51,10,80,60,40,40,30,3
76104125148187232265299343
6488106126159198226255292
23,0031,5042,5057,5076,00101,00129,00159,00189,00
20
Bare Copper
21
Cable Description
Installation Information
Properties
High conductivity plain soft stranded copper conductors to SANS 1411.
For the wiring of earthing circuits where general house wiring is used.• 1,5mm² - Amp's @ 30°C = 20 • 2,5mm² - Amp's @ 30°C = 27• 4,00mm² - Amp's @ 30°C = 37 • 6,00mm² - Amp's @ 30°C = 70
SANS 1411-1-10°C to 70°CCopper1,5mm² - 6mm², 5kg & 25kg coils10mm² - 16mm², 25kg & 500kg wooden drums25mm² - 240mm² & 500kg wooden drums
Specification :Temperature Range :Sheath Identification :Packaging :
::
Bare CopperEarth Wiring Cable
Technical Data
ConductorSize
ApproximateMeters
NominalStranding
(mm²) (No. x Diameter) (mm.kg)
1,52,54610162535507095120150185240
7/0,537/0,667/0,857/1,047/1,357/1,67
19/1,38*19/1,62*19/1,88*19/2,28*19/2,5037/2,0337/2,2837/2,5037/2,98
72,2246,6227,4618,7511,137,274,543,342,461,561,130,910,7390,5990,450
* Note
Example
: Compacted conductors
: Customer requires : 180m of 70mm² Copper Earth, Wire. 1kg of 70mm² Copper is therefore = 1,58m.So 180m divided by 1,58 = 113,92kg say 114kg
22
Low Voltage Armoured Cables
23
Electrical and physical properties of 3 and 4 core PVC insulated PVC bedded *SWA PVC sheathed 600/1000 V cables withaluminium or copper conductors and manufactured to SANS 1507-3.
* Where the armouring of cable is used as the earth continuity path, it may be necessary to replace some of the steel wires withtinned copper wires (ECC) or to use a supplementary earth continuity conductor.
Bells & Mains CablePVC PVC SWA PVC (FR) BLK/Red
Technical Data
Copper Conductors
24
1,52,54610162535507095120150185240300
8,519,6111,4012,5814,5916,5519,4620,8924,2627,0731,1933,3836,6840,8246,4351,10
243242537091119143169210251285320361416465
20263443587596116138171205234263298344385
192635456283110135163207251290332378445510
0,170,280,460,691,151,842,874,025,758,0510,9213,8017,2521,2727,6034,50
9,3310,5612,5713,9016,1419,1821,3423,9728,1431,2935,8238,1042,0546,7553,0658,53
1,251,251,251,251,251,251,601,601,602,002,002,002,002,502,502,50
1,251,251,251,251,251,251,601,601,602,002,002,002,002,502,502,50
14,1315,2317,0218,4
20,4122,3726,4627,8931,4635,4739,9942,1845,9851,1257,1362,20
14,9516,1818,3919,7221,9625,9228,3431,1736,5440,0944,6247,4052,6557,4564,1670,13
4485226677909961295183822152871361749015720690886901076712950
501597762910116917682196273238934837611572699250110391372616544
14,488,875,523,692,191,38
0,87490,63350,47180,33250,24600,20120,16980,14450,12200,1090
25,08015,3639,5616,3913,7932,3901,5151,0970,8170,5760,4270,3480,2940,2500,2110,189
CableSize
Current Rating VoltDrop
1 SecShortCircuitRating
Electrical Properties Physical Properties
Impe-dance
(A) (A)
Ground AirDucts
(A)(mm²) (mV/A/m)( /km)� (kA) (mm) (mm) (mm) (mm)(mm)(mm)
3c 3c 3c 3c4c 4c 4c 4c
(kg/km)(kg/km)
D1 d D2
Nominal DiametersApprox.
Mass
Aluminium Conductors
Under short circuit conditions a maximum conductor temerature of 160 C is allowed for a maximum of 1 secondo
CableSize
Current Rating VoltDrop
1 SecShortCircuitRating
Electrical Properties Physical Properties
Impe-dance
(A)
Ground AirDucts
(A)(A)(mm²) (mV/A/m)( /km)� (kA) (mm) (mm) (mm) (mm)(mm)(mm)
3c 3c 3c 3c4c 4c 4c 4c
(kg/km)(kg/km)
D1 d D2
Nominal DiametersApprox.
Mass
2535507095120150185240
90108129158192219245278324
7387104130157179201229268
8099119151186216250287342
1,44461,04650,77490,53880,39340,31480,26070,21330,1708
2,5021,8131,342
0,93330,6810,5450,4520,3690,296
1,802,523,615,056,868,6610,8313,3517,32
17,7619,3321,8724,7628,6831,0933,9937,8042,60
20,6521,9325,0529,2733,7335,4439,3944,5150,04
1,601,601,601,602,002,002,002,002,50
1,601,601,601,602,002,002,502,502,50
24,7626,3329,0731,9637,0839,8942,7947,1052,90
27,6529,1332,2537,6742,5344,2449,6954,8161,14
130114771782213229083328383745575977
155417572150293036474023527662317550
PVC Current Ratings are Based on the following Environmental Parameters
Maximum SustainedConductor
Temperature
GroundTemperature
Ambient AirTemperature
(Free Air Shaded)
Depth of Layingto top of
Cable or Duct
GroundThermalResistivity
70 Co 25 Co 30 Co 1,2 K.m/W 500mm
Electrical and physical properties of Multicore PVC Insulated PVC Bedded *SWA PVC sheathed 600/1000V cables with strandedcopper conductors manufactured to SANS 1507-3.
* Where the armouring of cable is used as the earth continuity path, it may be necessary to replace some of the steel wires withtinned copper wires (ECC) or to use a supplementary earth continuity conductor.
Multicore CableLow-voltage Armoured Cable
PVC Current Ratings are Based on the following Environmental Parameters
2.5mm² Multicore Cables
1.5mm² Multicore Cables
Technical Data
25
23456781012141924273037
29242421201817161514121111109
23202017161514131211109887
2219191716151413121211101099
14,478214,478214,478214,478214,478214,478214,478214,478214,478214,478214,478214,478214,478214,478214,4782
422422422422422422422413413413379379379379379
8,18,69,510,311,411,412,614,815,316,219,222,422,923,725,9
1,251,251,251,251,251,251,251,251,251,601,601,601,601,601,60
13,814,315,115,817,017,018,220,721,222,025,929,329,830,732,8
42245651057761362971083790198014041687178318672153
No ofCores
Electrical Properties Physical Properties
CapacitanceImpedanceCurrent Rating Nominal Diameters
Mass
d(A) (A)
Ground AirDucts
(A) ( /km)� (nF/lm) D2 (kg/km)D1
(mm)
Maximum SustainedConductor
Temperature
GroundTemperature
Ambient AirTemperature
(Free Air Shaded)
Depth of Layingto top of
Cable or Duct
GroundThermalResistivity
70 Co 25 Co 30 Co 1,2 K.m/W 500mm
No ofCores
Electrical Properties Physical Properties
CapacitanceImpedanceCurrent Rating Nominal Diameters
Mass
d(A) (A)
Ground AirDucts
(A) ��/km) (nF/lm) D2 (kg/km)D1
(mm)
8,86688,86688,86688,86688,86688,86688,86688,86688,86688,86688,86688,86688,86688,86688,8668
14,715,216,217
18,518,518,922,524,825,728,132,032,634,837,6
487487487487487487487477434434434434434434410
9,09,610,611,512,712,713,016,618,119,021,425,125,726,629,4
1,251,251,251,251,251,251,251,601,601,601,601,601,602,002,00
475524606690737756806
10001306142116952053218125943011
23456781012141924273037
373232272524222119181614141312
312626222019181715141312111010
312626222120191817161413131211
* Note: - D is overall diameter of one cable
26
Technical Data
No ofCores
Electrical Properties Physical Properties
CapacitanceImpedanceCurrent Rating Nominal Diameters
Mass
d(A) (A)
Ground AirDucts
(A) ( /km)� (nF/lm) D2 (kg/km)D1
(mm)
234567810121419
59766976488496198610791251121118852282
16,317,018,419,721,021,024,227,028,229,632,5
1,251,251,251,251,251,251,251,601,601,602,00
10,210,912,313,614,914,918,120,220,422,824,9
487487487487487487487477434434434
5,51715,51715,51715,51715,51715,51715,51715,51715,51715,51715,5171
4135352928262524222119
4134342827252422201916
5042423533312927252321
4mm² Multicore Cables
6mm² Multicore Cables
No ofCores
Electrical Properties Physical Properties
CapacitanceImpedanceCurrent Rating Nominal Diameters
Mass
d(A) (A)
Ground AirDucts
(A) ( /km)� (nF/lm) D2 (kg/km)D1
(mm)
234
625353
514343
534545
3,68683,68683,6868
556556556
11,812,613,9
1,251,251,25
17,418,419,7
684791911
Sustained Current Rating Factors for Non-Standard Conditions for both PVDAC and Multicore LV PVC Cables
GroundTemperature (°C)
AirTemperature (°C)
MaximumConductor
Temperature(°C)
MaximumConductor
Temperature(°C)
7025
1,0030
0,9435
0,8840
0,82 7030
1,0035
0,9440
0,8745
0,79
Depth of Laying (mm) Direct in Ground
500800100012501500
1,000,960,940,920,90
Current Rating Factors for Grouping of Multicore Cables Installed Horizontally in Air
No ofCables
in group
Direct in ground
Axial Spacing (mm)
Touching 150 300 450 600
23456
0,810,700,630,590,55
0,870,780,740,700,67
0,910,840,810,780,76
0,930,870,860,830,82
0,940,900,890,870,86
ConditionCables touchingClearance D* between cables
0,860,91
0,810,89
0,750,87
0,740,87
0,720,85
Derating FactorNo of Cables 2 3 5 6 9
Multicore CableLow-voltage Armoured Cable
Single Core CableLow-voltage AWA
Electrical and physical properties of single core stranded copper conductors, PVC Insulated, PVC bedded, AWA PVC sheathed600 / 1000V cables manufactured to SANS 1507-3.
27
PVC Current Ratings are Based on the following Environmental Parameters
Technical Data
RatedArea Current Rating
Approximate Diameters
Cables inTrefoil Formation
D1 D2 (kg/km)d (A)(mm²) (A) (mV)(A)( /km)�
Maximum SustainedConductor
Temperature
GroundTemperature
Ambient AirTemperature
Depth of Layingto top of Cable
GroundThermalResistivity
70 Co 25 Co 30 Co 1,2 K.m/W 500mm
Ground Ducts Air
Approx.
MassImpedance
Voltage Dropper Amp
per metre
2535507095120150185240300400500630
8,359,4010,9512,5914,7416,1617,9920,1023,1126,2529,5032,5138,75
1,251,251,251,251,251,601,601,601,602,02,02,02,5
15,4516,5018,0519,8922,0425,1626,9929,3032,3137,0541,5044,5151,75
5637008461128150417842102254731144124513362038218
0,8790,6390,4790,3390,2570,2130,1820,1570,1340,1230,1130,1060,099
125156183223266301336370410476529581623
112140165200238269299329363420465509541
121147177221273314357401481546622695779
1,521,110,830,590,450,370.320,270,230,210,190,180,17
Electrodac Cables
28
Phase Conductor Resistance* (Ohm/km)Earth Conductor Resistance* (Ohm/km)Impedance (Z) (Ohm/km)Current Rating** (A)1 Second Short Circuit Rating (kA)
1,831,832,3487
1,43
1,151,151,471122,29
0,730,730,931353,57
Cable Size (mm²) 10 16 25
Cable Description
Installation Information
Properties
3 circular stranded plain soft copper conductors, XLPE insulated, layed up with one circular stranded tinned soft copper earthingconductor, collectively screened with an aluminium polyethylene laminate (APL) tape, polyethylene sheathed undergroundsupply cable.
Use of intermediate Voltage allows increased power transfer over long distances with smaller conductor sizes, eg for loadstypically 25 kVA this represents a considerable saving when compared to conventional systems.This cable is therefore intendedfor supplying such loads over distances where using 11kV would provide a more reliable but far more expensive solution.
• Underground cable - with a specially adapted tractor, the cable can be buried with minimum labour, and therefore more costeffective.
• Screened cable construction for ease of fault location.• Buried cable results in a "clean" landscape - no poles or overhead lines to hinder farm vehicles.
SANS 1507-4-10°C to 90°C1900 / 3300VRed,Yellow, Blue and bare tinned earth conductor
Specification :Temperature Range :Voltage Rating :Core Identification :
Interdac 3 Cable3 Phase 1.9/3.3 kV
Technical Data
29
Note: * DC @ 20°C** In ground. Soil temperature 25°C. Depth of lay 500mm. Soil thermal resistivity 1,2 K.m/W. Operating temperature 90°C
Electrical Properties
Mechanical Properties
10 2516Cable Size (mm²)
Phase Conductor Construction (no. x diam.) (mm)Earth Conductor Construction (no. x diam.) (mm)InsulationThickness (nominal) (mm)Aluminium ScreenThickness (mm)SheathThickness (nominal) (mm)Cable Diameter (nominal) (mm)Approximate Cable Mass (kg/km)Minimum Bending Radius (mm)
7 x 1,337 x 1,33
3,00,151,825,5728255
7 x 1,677 x 1,67
3,00,151,827,2923272
19 x 1,3819 x 1,38
3,00,152,030,21303302
Cable Description
Circular stranded hard drawn copper phase conductor, XLPE insulated with concentrically arranged identified neutral and bareearth conductors. Polyethylene sheathed 600/1000V service connection cable. Nylon ripcord laid under sheath. Manufactured toSANS 1507 -6.
• Small overall diameter - concentric construction (SNE - Seperate Neutral Earth).• Lower mass - due to smaller diameter - no steel wire armour.• Increased safety - reliable earthing.• Improved reliability - UV stable sheath and core insulation and water blocked.• Tamper and vandal proof - unauthorised access to phase conductor inhibited by concentric layer.• Easy strip with nylon ripcord.
Airdac SNE CableHouse Service Connecting Cable with or without Pilot Cores
Note: * Assuming worst conditions, i.e. - 5,5 °C with simultaneous wind speed of 31 m/s and measured at midspan.** UTS = Minimum ultimate tensile strength.*** MWT = Minimum working tension.
30
Technical Data
Electrical Properties
Cable Size (mm²) 10 16
Phase Conductor Resistance (Ohm/km) DC @ 20 °CEarth Size (mm²)Neutral Size (mm²)Phase Core Impedance (Z) (Ohm/km)Current Rating* (A)Pilot Cores (No. x OD) Solid (mm)
1,907,510
2,3450
2 x 1,13
1,201016
1,4770
2 x 1,13
* Note: - In air, with 30 °C ambient with maximum conductor temperature 90 °C
Mechanical Properties
Installation Data
Cable Size (mm²) 10 16
Phase Conductor (No. x OD)(mm)Nominal InsulationThickness (mm)Neutral Conductor (No. x OD)(mm)Earth Conductor (No. x OD)(mm)Nominal SheathThickness (mm)Approximate Cable OD (mm)Approximate Cable Mass (kg/km)
7 x 1,351,0
7 x 1,333 x 1,78
1,612,8320
7 x 1,671,0
7 x 1,763 x 2,20
1,614,5485
Span (m) 10 20 30 40 50Based on
UTS** MWT***
SAG* (mm)SAG* (mm)
10 mm²16 mm²
4540
180170
400380
710670
11101050
36005760
9001440
Cable Description
Circular stranded hard-drawn copper phase conductor, XLPE insulated with concentrically arranged bare earth conductors.Polyethylene sheathed 600/1000 V house service connection cable. Nylon ripcord laid under sheath. Manufactured to SANS1507-6.
• Small overall diameter - concentric construction• Lower mass - due to smaller diameter - no steel wire armour• Increased safety - reliable earthing• Improved reliability - UV stable sheath and core insulation• Tamper and vandal proof - unauthorised access to phase conductor inhibited by concentric layer• Easy strip with nylon ripcord
Airdac II CNE CableHouse Service Connect
Note: * Assuming worst conditions, i.e. temperature -5,5°C with simultaneous wind speed of 31m/s and measured at midspan.** UTS = Minimum ultimate tensile strength. Safety factor of 2,5.*** MWT = Minimum working tension.
31
Technical Data
Electrical Properties
Cable Size (mm²) 4
4
10
10
* Note: - In air, with 30 °C ambient with maximum conductor temperature 90 °C
Mechanical Properties
Installation Data
Cable Size (mm²)
Span (m) 10 20 30 40 50Based on
UTS** MWT***
SAG* (mm)SAG* (mm)
Phase Conductor Resistance (Ohm/km) DC @ 20 °CPhase Core Impedance (Z) (Ohm/km)Current Rating (A)*Symmetrical Short Circuit Rating for 1s in kA
4,805,8830
0,572
1,902,3450
1,431
Phase Conductor {No. x OD} (mm)Nominal InsulationThickness (mm)Earth Size (mm²)Earth Conductor {No. x OD} (mm)Nominal SheathThickness (mm)Approximate Cable OD (mm)Approximate Cable Mass (kg/km)
7 x 0,921,04
8 x 0,851,49,0121
7 x 1,451,010
18 x 0,851,411,0249
370900
14803600
1020870
650550
370310
165140
4035
4 mm²10 mm²
Cable Description
Installation Information
Properties
Self-supporting system consists of four cores of hard-drawn stranded and compacted aluminum conductors of equal cross-section and insulated with carbon-loaded XLPE to ensure UV protection. All cores strained equally. Supporting-core systemconsists of three phase cores of hard-drawn stranded compacted aluminium conductors insulated with carbon- loaded XLPE laidup around an aluminium-alloy supporting core insulated with carbon loaded XLPE to ensure UV protection. Additional sub-conductors optional in both self-supporting and supporting-core systems.
• Economical • Flexible • Safe • Vandal proof • Durable • Aesthetically pleasing • Adaptable
Specification : SANS 1418 Part 1 and 2Temperature Range : -10°C to 80°CVoltage Rating : 600 / 1000VCore Identification : Phase 1,2 and 3 indented, • Non strain-bearing neutral, 2 longitudinal ribs on opposite surfaces 0,5mm x
1,00mm • Strain-bearing (supporting) neutral, 1 longitudinal rib on one surface 0,5mm x 1,00mmPackaging : Available on 500 metre wooden drums
Aerial Bundle Conductor (ABC) Cable
32
Technical Data
Electrical Properties
(A)mm² mm²kA ( /km)� ( /km)� ( /km)� ( /km)�( /km)�( /km)�
(mm)
CableSize
CurrentRating
(Note 1)
Short CircuitRating
(Note 2)
ConductorResistance
@ 20°C
ConductorResistance(ac) @ 80°C
Self Supporting System Supporting Core System
InductionReactance
@ 50Hz
Impendance(z) @ 50Hz
at 80°C
SupportingCore Size
InductionReactance
@ 50Hz
Impendance(z) @ 50Hz
at 80°C
2535507095120150
105144183228277322350
2,33,24,66,48,511,013,8
1,2000,8680,6410,4430,3200,2530,206
1,4901,0780,7960,5500,3970,3140,256
0,0960,0960,0900,0890,0860,0840,082
1,4931,0820,8010,5570,4060,3250,269
54,654,654,654,654,67095
0,1010,0970,0890,0860,0810,0790,079
1,4931,0820,8010,5570,4050,3240,268
NOTES : 1.
2.
Continuous current ratings are given for ambient temperature of 35 °C, and maximum conductortemperature of 80 °C. For other ambient temperatures use adjoining rating factorsShort circuit ratings of 1 second duration, for a final conductor temperature of 130 ° C.
Temp °C 25 30 351.00 0.94
40 450.881.051.11Factor
Mechanical Properties
(mm) (mm) (mm) (mm)mm² mm²(kg/km) (kg/km)(kN) (kN)
(mm)
CableSize
ConductorDiameter
CoreDiameter Approx.
AssemblyDiameter
Approx.AssemblyDiameter
Approx.Assembly
Mass
Approx.Assembly
Mass
Self Supporting System Supporting Core System
MaximumDesignLoad
MaximumDesignLoad
SupportingCore Size
Phase Cores
2535507095120150
2535507095120150
Min MinMax Max
5,66,67,79,311,012,513,9
6,57,58,610,212,013,515,0
8,49,810,912,914,616,117,5
9,611,112,314,316,217,519,2
25272933374145
25323438424448
400540697982130214702011
5056458021087140715752116
57914192430
54,654,654,654,654,670,095,0
26283234384044
32343638425056
507612730944118316001870
6127178351049128817051975
66666813
N/A N/A N/A N/A N/A N/A N/A
Above Plus 25mm² Auxiliary Core
Silicone Cables
33
Cable Description
Installation Information
Properties
High conductivity tinned stranded, flexible copper conductors to SANS 1411 Part 1. Insulated with Silicone RubberType RD7 andsheathed with Silicone RubberType RS8 to SANS 1574 Part 4Type R7, H05SS-F.
For the wiring of all types of:• Stoves • Electrical Motors and Pumps• Fluorescent Lights • All otherTypes of HighTemperature Appliances
SANS 1574-4 Pt4-50°C to 150°C300 / 500V3 Core - Blue, Brown andYellow/Green, 4 Core - Blue, Brown, Black andYellow/GreenInsulation and sheath is halogen free and has a low smoke emission.Limiting Oxygen Index is 24%100m Shrink-wrapped coils
Specification :Temperature Range :Voltage Rating :Core Identification :
::
Packaging :
(Capable of current rating at 180°C if there are no limits imposed by environmental conditions)
Silicone Cabtyre CableFlexible Wiring
Assumed ambient temperature 80°CMaximum Conductor temperature 150°CDerating of Current Rating for other Ambient Temperatures
: 40 60 80 100 120 140 160: 1,22 1,12 1 0,87 0,73 0,57 0,37
Ambient temperature, ºC
Rating factor, X
34
Technical Data
CableSize
ConductorAC Resistance
@ 150°C
CurrentRating
*
Approx.Cable
Diameter
Approx.CableMass
NominalStranding
No. x diameter
(mm²) (A)(mm) (kg/km)(kg/km) ( /km)�
Numberof
Cores
0,75
1
1,5
2,5
4
24/0,2 7,6
9,932/0,2
30/0,25
50/0,25
56/0,3
40,3
30,2
20,7
12,4
7,7
1717
21
26
36
56
3
3
3
4
10,8
10.6
13,5
14.8
11.6
11.8
3
4
3
4
72
127
135
160
192
237
283
345
* Note:
Ambient temperature, ºC
Rating factor, X
- Capable of continuous current rating at 180°C and 250°C (See table) if there are no limitsimposed by environmental conditions.
- Ambient temperature, 80ºC- Maximum Conductor temperature 150°C (See table)- Derating of Current Rating for other Ambient Temperatures
: 40 60 80 100 120 140 160: 1,22 1,12 1 0,87 0,73 0,57 0,37
Cable Description
Installation Information
Properties
High conductivity tinned stranded, flexible copper conductors to SANS 1411 Part 1. Insulated with Silicone RubberType RD7 toSABS 1574 Part 4, H05S-F & HIS-F in various colours.
For the wiring of all types of:• Control Panels • Appliances• Light Fittings • All HighTemperature Applications
SANS 1574 Pt4-50°C to 150°C300 / 500V (0,5 mm² - 16 mm²) and 600 / 1000V (0,5 mm² - 95 mm²)Red, Black, Blue, Brown, Green/Yellow andWhite (Other colours available on request)Insulation is halogen free and has a low smoke emission. Limiting Oxygen Index is 24%.Shrink-wrapped- coils 100m 0,5 - 35 mm²- reels 100m 50 mm²- 50m 70 - 95 mm²- Barrels 4000m 0,5 - 1,0 mm²- Barrels 3000m 1,5 mm²- Barrels 2500m 2,5 mm²
Specification :Temperature Range :Voltage Rating :Core Identification :
:Packaging :
(Capable of current rating at 180°C if there are no limits imposed by environmental conditions)
35
Technical Data
Silicone Single CableFlexible Wiring
ConductorAC
Resistance
Current Rating *Approx.Cable
Diameter
(A)(mm) ( /km)�
300/500V 600/1000V 180°C 180°C
SingleCable
Cables inTrefoil
180°C 300/500V
2,22,42,53,23,94,75,26,67,6
65,343,532,622,313,48,295,523,182,021,290,920,640,450,34
2,62,83,03,33,74,85,36,37,29,510,913,214,417,3
N/A
21263037496581112143190230282352423
131719243142527292124151186234285
CableSize
NominalStranding
No. x diameter
(mm²)
0,50,75
11,52,54610162535507095
16/0,224/0,232/0,2
30/0,2550/0,2556/0,381/0,377/0,4125/0,4184/0,4267/0,4378/0,4341/0,5456/0,5
Approx.CableMass
(kg/km)
600/1000V
8,811,714,322,434,752,471,2117,8180,7
10,713,418,123,937,454,475,2118,5180,72803915517501010
N/A
* Note:
Ambient temperature, ºC
Rating factor, X
- Derating of Current Rating for other Ambient Temperatures
: 40 60 80 100 120 140 160: 1,22 1,12 1 0,87 0,73 0,57 0,37
Cable Description
Installation Information
Properties
High conductivity tinned stranded, flexible copper conductors to SANS 1411 Part 1. Insulated with Silicone RubberType RD7 andlayered with varnished impregnated Glass Fibre or Polyester Braid to SANS 1574 Part 4, HIST-F and H05SJ-F. C.
• The internal wiring of all kinds of domestic, industrial, mining, automotive, aeronautical and marine equipment, where highoperating temperatures prevail.• Also applications that require medium mechanical protection against damage to the silicon in the form of a protective braid.
SANS 1574 Pt4-50°C to 150°CGlass Fibre Braided 300 / 500V, Polyester Braided 600 / 1000VBlack & Red (Polyester Braided 1mm² to 4mm²), Yellow (Polyester Braided 6mm² and larger). White,Blue, Brown (Glass Fibre Braided), Insulation is halogen free and has a low smoke emission. LimitingOxygen Index is 24 %.Anti-fray and anti-pushback braidingShrink-wrapped coils- 100m 0,5 - 35mm²- 50m 50 - 95mm²
Specification :Temperature Range :Voltage Rating :Colour Identification :
Packaging :
(Capable of current rating at 180°C if there are no limits imposed by environmental conditions)
Special Silicone CablePolyester & Glass Fibre Braided
36
Technical Data
Polyester Braided (600 / 1000V)
CableSize
ConductorResistance
at 150°C
Current Rating *Approx.Cable
Diameter
Approx.CableMass
NominalStranding
No. x diameter
(mm²) (A)(mm) (kg/km)( /km)�
SingleCable
Cables inTrefoil
11,52,54
1,01,52,54610162535507095
32/0,230/0,2550/0,2556/0,3
32/0,244/0,2
50/0,2556/0,381/0,377/0,4125/0,4184/0,4267/0,4378/0,4341/0,5456/0,5
2,83,54,14,8
3,53,84,55
5,66,98
9,911,613,715,317,6
30,220,712,47,7
30,222,313,48,295,523,182,021,290,920,640,450,34
27354865
2435486583118155212265338418512
19233038
17243444547185160213255304348
16,925
38,356,9
19,526,039,255,474119181262373524702940
Glass Fibre Braided (300 / 500V)
General Information
37
CONDUCTORS
INSULATION
BEDDING AND SHEATHING (E.T.C)
ARMOURING (E.T.C)
CABLETYPE
AL -
PHDC -
PSC -
SOL AL -
TSC -
EPM -
EPM/CM -
PE -
PVC -
PVC (FR) -
PVC (FR LH) -
PVC (N) -
XLPE -
APL / PE -
CM -
CR -
CRR -
EVA -
PE -
PVC -
PVC (FR) -
PVC (FR LH) -
SIL (QR) -
AWA -
CNE -
COLL SCR -
DSTA -
DWA -
EMS -
IND SCR -
SNE -
SWA -
SWA/ECC -
TCB -
GWI -
HD -
H03 VV-F -
H05 VV-F -
HQR -
LD -
ND -
PVDAC -
PVI -
QR -
SWC -
Aluminium Conductor (stranded)Plain Hard Drawn CopperPlain Soft CopperSolid Aluminium ConductorTinned Soft Copper
Ethylene Propylene MonomerCo-Extruded EPM/CMPolyethylenePolyvinyl ChloridePolyvinyl Chloride Fire RetardantPolyvinyl Chloride Fire Retardant and Low Halogen Gas EmissionPolyvinyl Chloride (Nitrile)Cross-linked Polyethylene
AL Polyethylene Laminate (Longitudinal) with Polyethylene SheathChloronated-PolyethylenePolyethylenePolychloroprene ReinforcedEthylene Vinyl AcetatePolyethylenePolyvinyl ChloridePolyvinyl Chloride Fire RetardantPolyvinyl Chloride Fire Retardant and Low Halogen Gas EmissionSilicone
Aluminium Wire ArmouredConcentric Neutral EarthCollectively ScreenedDouble Steel Tape ArmouredDouble Steel Wire ArmouredElectromagnetc ScreenedIndividually ScreenedSplit Neutral and EarthSingle Steel Wire ArmouredSteel Wire Armour with Earth Continuity ConductorTinned Copper Braided
General Wire IndustryHeavy Duty 600/1000VHarmonised 300/300 V PVC Insulated PVC Sheathed FlexibleHarmonised 300/500 V PVC Insulated PVC Sheathed FlexibleHigh Temperature Heat Resistant (105°)Light Duty 300/300 VNormal Duty 300/500 VPVC Insulated, PVC Bedded, SWA, PVC SheathedPVC Insulated Single Core FlexiblesSiliconeSurface Wiring Cable (Surfix)
AbbreviationsApplicable to Cable Descriptions
38
UsefulTechnical Data
where = Short circuit rating in ampsK = A constant combining temperature limits
and properties of conductor materialsA = Area of conductort = Duration of short circuit in seconds
Isc
39
ColourCode
Correction Factor
1250 W/m²
(Highveld)
1000 W/m²
(Coastal)
Solar Radiation
1,5 - 1016 - 3550 - 95
120 - 185240 - 400
0,700,680,650,620,59
0,620,570,530,490,44
Values of conductor / temperature constant K
InsulationMaterial
Short CircuitTemp °C
OperatingTemp °C
ConductorMaterial
K Factor
PVCPVC
CopperAluminium
7070
160160
11576
PVC Insulated Cables 1000V
8 x d10 x d
Multi and Single Core 16 - 50 mm²70 mm² and greater
Short Circuit Ratings for PVC Insulated Cables
Bending Radii
Correction Factors for Direct Solar Radiation
FLAMOSAFE RANGE OF FIRE PERFORMANCE OF ELECTRIC CABLES
NHLSFR (Non Halogen) White
Stripe cables
(LOTOX )
are designed to reduceflame propagation and smoke inthose instances where a fire maydevelop. By replacing the standardPVC with XLPE insulation and EVAbedding and outer sheath, no HCIgases will be liberated during theburning of the cables. ®
LHFR (Low Halogen) Blue Stripe
cables
(LOHAL )