Low p T Muon trigger studies for J/ Supreet Pal Singh (Panjab University, Chandigarh) Prof....
-
Upload
loren-campbell -
Category
Documents
-
view
223 -
download
2
Transcript of Low p T Muon trigger studies for J/ Supreet Pal Singh (Panjab University, Chandigarh) Prof....
Low pT Muon trigger studies for J/
Supreet Pal Singh (Panjab University, Chandigarh)
Prof. J.B.Singh (Panjab University, Chandigarh)
Prof. Kajari Mazumdar (TIFR, Mumbai)
1India-CMS Meeting 29th-30th July 2010
MotivationStudy of quarkonium production at high energy collision is always
interesting testing ground of non-relativistic QCD including the technique of factorisation:
production of heavy quark-antiquark pair calculated in perturbative method.
non-perturbative effects which bind the heavy quark pair into a quarkonium various models try to describe this, eg. , colour singlet, colour octet, etc.
Final state polarisation depends on the model as well as the transverse momentum of the produced J/ψ .
Experimental data till now is unable to resolve various issues at LHC physics of J/ψ will be pursued hot through differential cross-section
d (J/ψ)/ dPT, polarisation measurements, etc.
2India-CMS Meeting 29th-30th July 2010
New Trigger paths at HLT proposed
At LHC startup the actual instantaneous luminosity is lower than anticipated low pT physics can be studied using softer triggers than planned earlier. At high instantaneous lumi, low
threshold triggers will have to be prescaled.
J event statistics should be high enough to be competitive with other experiments at the early stage of CMS.
Need as low PT Jevent sample as possible produced in mid-rapidity regions atleast.
• In 70% of J dimuons that CMS can reconstruct in minimum bias events, one of the muon can be only a tracker muon, and NOT a global muon
• Thus GT and TT samples are crucial to cover low pT range , especially for | ~ 1 - 2.5India-CMS Meeting 29th-30th July 2010
Way out in CMS: devise a double muon trigger at HLT to catch low pt tracks from J/ ψ Start with standard L1 info
L1 firmware remains unchanged
Combine Global Muon + track of J/ψ trigger rate < 10 Hz, tolerable.
Distribution of J/ψ dimuons in phase space.
• HLT_MuX_Track0_Jpsi A new trigger configuration where a single L3 muon is combined to tracker track within invariant mass window of 2.8-3.4 GeV/c2 . Different trigger configurations possible with transverse momentum cut on L3 muon.
HLT_Mu0_Track0_Jpsi : L3 Muon pT > 0 GeV/c,
HLT_Mu1p5_Track0_Jpsi : L3 Muon pT > 1.5 GeV/c,
HLT_Mu2_Track0_Jpsi : L3 Muon pT > 2 GeV/c,
HLT_Mu3_Track0_Jpsi : L3 Muon pT > 3 GeV/c,
HLT_Mu5_Track0_Jpsi : L3 Muon pT > 5 GeV/c,
This lowers the trigger rate and the signal statistics are not reduced much.
Exercise for detremining gain of new path, evaluating trigger rates etc. during April, May, June of this year , strategy validated, trigger in placeMore work in progress.
pT distributions for different trigger Configurations
Dimuon combinations: GG global-global muons (black) GT global-tracker muons (red) ; TT tracker-tracker muons (blue)
Global muons Reconstruction starts from muon stations and matched to a track in tracker.Tracker muons Reconstruction starts in tracker and matched to a tracklet in muon station.
6India-CMS Meeting 29th-30th July 2010
Muon trigger rate will change with evolving luminosityMaximum trigger rate should be about 25 Hz with change in trigger path once a month, almost.
Efficiencies and trigger rates for different trigger configurations of “HLT_MuX_Track0_Jpsi”
pTmin [GeV/c]
of L3 Muon
Trigger Rate [Hz]
0.0 6.11.5 5.82.0 4.33.0 1.75.0 0.4
Going from Mu0 to Mu3 the trigger rates drops very strongly (good) but the signal efficiency also suffers.
We could set the muon pT threshold at 2.0 Gev/c instead of 3.0 GeV/c, to keep a good low pT coverage for a longer period.
8India-CMS Meeting 29th-30th July 2010
Effect of changing the pT cut on pixel and tracker track (matched to L3 muon) in HLT_Mu0_Track0_Jpsi.
Presently pT cut on pixel and tracker track 3.0 GeV
To improve the signal efficiency new cuts on pixel and tracker track pTpixel > 2.2 GeV/c pTtracker > 2.5 GeV/c
9India-CMS Meeting 29th-30th July 2010
Efficiencies for different configurations of HLT for various pT cuts
increase in the efficiency
10India-CMS Meeting 29th-30th July 2010
Before
After
pT & rapidity distributions and the corresponding Efficiencies for various HLT triggers for CMS Data run numbers (certified) 132440-135445
“Reference” trigger: HLT_L1MuOpen, Efficiencies of other trigger paths are calculated relative to the same for events passing the HLT_L1MuOpen trigger
11India-CMS Meeting 29th-30th July 2010
Mass distributions and the corresponding efficiencies CMS Data run numbers (certified) 132440-135445
HLT_L1MuOpen is prescaled after run rumber 135445 cannot be taken as a “default” trigger .
HLT_Mu3 is good only for pT > 3 GeV.
HLT_L1DoubleMuOpen is very efficient can be taken as reference to study HLT_Mu0_Track0_Jpsi till it is prescaled.
12India-CMS Meeting 29th-30th July 2010
pT & rapidity distributions and the corresponding Efficiencies for HLT_Mu0_Track0_Jpsi for CMS Data run numbers (certified) 135521-140076
13India-CMS Meeting 29th-30th July 2010
2D efficiency plot of the HLT_Mu0_Track0_Jpsi trigger path w.r.t. HLT_L1DoubleMuOpen trigger
• HLT_Mu0_Track0_Jsi trigger is best suited for mid-rapidity region No requirement for 2nd muon in DT, while HLT_L1DoubleMuOpen require hits in at least “two” DT segments.
• HLT_L1DoubleMuOpen is efficient but effected by background, cannot be used as unprescaled for long.
• HLT_Mu0_Track0_Jpsi “Cleaner” trigger.
14India-CMS Meeting 29th-30th July 2010
Keep ψ(2S) in the game !
Increase HLT mass window from 2.7 -- 3.5 GeV to 2.7 – 3.9 GeV the rate incrases by a factor of 1.5
Work in porgress
Summary
New J triggers in CMS: looser muon triggers (eg. no pt threshold)• HLT_Mu0 + track in the J/ mass window
Good for all physics analyses with a J/ in the final state Also gives a handle to measure all muon related efficiencies.
• Trigger rate for the different trigger configurations of HLT_Mu0_Track0_Jpsi has to be monitored carefully.
• The efficiency can be increased further by changing the pT cut on the pixel and tracker track to 2.2 GeV/c and 2.5 GeV/c.
• Data has started coming and HLT_Mu0_Track0_Jpsi has been included in the official HLT trigger paths.
• Favorable for polarization studies of low pT dimuons from J/ more statistics can be accumulated.
• Good Time ahead for physics with J/ muons
16India-CMS Meeting 29th-30th July 2010