LOC Tech

5
LOC OILTECH COOLERS COOLING SYSTEM Oiltech LOC with integrated circulation pump for industrial hydraulic systems COOLING SYSTEM Oiltech LOC with integrated circulation pump for industrial hydraulic systems

Transcript of LOC Tech

Page 1: LOC Tech

L O COILTECH

COOLERS

COOLING SYSTEMOiltech LOC with integrated circulation pump for

industrial hydraulic systems

COOLING SYSTEMOiltech LOC with integrated circulation pump for

industrial hydraulic systems

Page 2: LOC Tech

• Cooler matrix with low pressure drop and high cooling capacity

• Three-phase AC-motor.

• Cooling capacity up to 45 kW at ETD 40°C (40°C difference ininlet temperature oil/air).

• The pump can be installed turned in steps of 90° on the electromotor.

Oiltech LOC is one of the most reliable and efficient cooling system for oil cooling on themarket. The oil in your hydraulic system will operate with the ideal oil viscosity, providingextended service life and dependability for your entire hydraulic system.

Oiltech LOC cooling system consists of a cooler matrix, afan and a pump, The cooling system is fitted with oneelectromotor only minimising the electric installation,providing ease of assembly at a low cost of installation.

Ease of installationDuring the development of Oiltech LOC, cooling capacitytests, analyses of life cycle and structural strength have beenmade in our laboratory.All components have been thoroughlyselected for optimum performance. Compact design andease of mounting facilitates installation in small locations.The cooling system is supplied fit for installation in yoursystem.The Oiltech LOC can be fitted with a filter unit for oilcleaning, providing extended oil durability, hence extendedhydraulic system life. Functions such as pumping, coolingand filtering in one compact package assures optimalperformance at low cost.

Reliability in operation and extended life Oiltech LOC cooling system provides proven reliability,measured in lower maintenance costs, increased system

efficiency and expanded productivity. A controlled oiltemperature will result in extended component life.For flexibility of selection and application, Oiltech LOCstandard range is available in capacities from 2.8 kW to 45kW at ETD 40°C and oil flows from 20 l/min to 80 l/min.Fitted with Oiltech QPM quiet low-pressure pump, thesystem will operate with a uniform oil flow pattern.Pulsations and pressure spike problems from the hydraulicsystem are eliminated, providing extended system servicelife.The extremely high heat transfer capacity, the dependabilityin operation and the fact that Oiltech LOC provides long-lasting oil durability is significant for this cooling system.

Calculate your cooling requirement Oiltech has developed a calculation program where, byentering your basic data, you can calculate your coolingrequirement and select the correct cooling system. Theprogram is available from you local Olaer company.The Olaer Group is represented worldwide providing youwith support wherever you are located.

OILTECH LOC FOR OPTIMUM EFFICIENCY

2

Page 3: LOC Tech

Type A B C D E F G H I J K L* M N

Dust and stone guard

Air

Oiltech LOC 004-4-D-AOiltech LOC 007-4-D-AOiltech LOC 007-4-D-BOiltech LOC 007-4-D-COiltech LOC 007-4-D-DOiltech LOC 011-4-D-AOiltech LOC 011-4-D-BOiltech LOC 011-6-D-COiltech LOC 011-6-D-DOiltech LOC 011-4-D-COiltech LOC 011-4-D-DOiltech LOC 016-4-D-AOiltech LOC 016-4-D-BOiltech LOC 016-6-D-COiltech LOC 016-6-D-DOiltech LOC 016-4-D-COiltech LOC 016-4-D-DOiltech LOC 023-4-D-BOiltech LOC 023-6-D-COiltech LOC 023-6-D-DOiltech LOC 023-4-D-COiltech LOC 023-4-D-DOiltech LOC 033-6-A-DOiltech LOC 033-4-A-COiltech LOC 033-4-A-DOiltech LOC 044-6-A-DOiltech LOC 044-4-A-COiltech LOC 044-4-A-D

267365365365365440440440440440440496496496496496496580580580580580692692692692692692

287395395395395470470470470470470526526526526526526610610610610610722722722866866866

134203203203203203203203203203203203203203203203203356356356356356356356356356356356

6681818181119119119119119119147147147147147147112112112112112168168168168168168

500526539586599551564611624611624610623636649636649648661717704717754722735779746759

420510510510510510510510510510510510510510510510510610610610610610610610610610610610

80160160160160230230230230230230230230230230230230305305305305305406406406584584584

77103103103103106106106106106106100100100100100100101101101101101103103103878787

130112112112112110110110110110110114114114114114114112112112112112101101101101101101

169212212212212250250250250250250278278278278278278320320320320320376376376448448448

163190190190190215215215215215215240240240240240240265265265265265240240240265265265

63424242423939393939394545454545454444444444434343595959

G1G1G1G1G1G1G1G1G1G1G1G1G1G1G1G1G1G1G1G1G1G1

G11/4

G11/4

G11/4

G11/4

G11/4

G11/4

6262758710062758710087100627587100871007587100871001008710010087100

Oil

General drawing

Dimensions

*

* "L" when a by-pass valve type S is used

3

Page 4: LOC Tech

Air f

low

(m3 /s

ec)

Num

ber o

f pol

es -

Cool

ing

capa

city*

Fan

diam

eter

(mm

)W

eigh

t app

rox.

kg

Nom

. oil

flow

(l/m

in)

Cool

ing

capa

city

(kW

/°C)

Acou

stic

pres

sure

L pA

(dB(

A)) 1

m**

Cool

ing

capa

city

in k

W a

t ETD

40°

C

Type

Technical specification, cooler matrix

Maximum static working pressure 21 bar

Dynamic working pressure 14 bar. Tested acc. to ISO/DIS 10771-1

Heat transfer tolerance ±6 %

Technical specification, three phase-motor

Three-phase asynchronous motor acc. to IEC 34-1, IEC 72 to DIN 57530/VDE 0530

Rated voltage: 50 Hz 220-240V/380-420V or 60 Hz 255-290V/440-480V

Rise in temperature B

Insulation class F

Protection standard IP 55

* Specified electromotors are calculated for max. working pressure 6 bar at 125 cSt and 50 Hz; 4 bar at 125 cSt and 60 Hz. For working pressures above this, consult your local Olaer company for higher rated electromotors.

** Noise level tolerance ± 3 dB(A).

• Oiltech LOC, designed for use with synthetic oils, vegetable oils and mineral oil type HL/HLP according to DIN 51524. Maximum oil temperature 100°C.

• Maximum negative pressure in suction line 0,4 bar with oil-filled pump.

• with oil temperatures >100°C • with oil viscosity > 100 cSt/other fluids• in aggressive environments• ambients, rich in particles• at high altitudes

Consult your local Olaer company for use

Fan blades/hub Glass fibre reinforcedpolypropylene/aluminium

Material

Pump housing/Matrix Aluminium

Fan housing Steel

Fan guard Steel

Other parts Steel

Surface treatment Electrostatic powder coating

Acou

stic

pow

er L W

A(d

B(A)

)

Oiltech LOC 004-4-D-AOiltech LOC 007-4-D-AOiltech LOC 007-4-D-BOiltech LOC 007-4-D-COiltech LOC 007-4-D-DOiltech LOC 011-4-D-AOiltech LOC 011-4-D-BOiltech LOC 011-6-D-COiltech LOC 011-6-D-DOiltech LOC 011-4-D-COiltech LOC 011-4-D-DOiltech LOC 016-4-D-AOiltech LOC 016-4-D-BOiltech LOC 016-6-D-COiltech LOC 016-6-D-DOiltech LOC 016-4-D-COiltech LOC 016-4-D-DOiltech LOC 023-4-D-BOiltech LOC 023-6-D-COiltech LOC 023-6-D-DOiltech LOC 023-4-D-COiltech LOC 023-4-D-DOiltech LOC 033-6-A-DOiltech LOC 033-4-A-COiltech LOC 033-4-A-DOiltech LOC 044-6-A-DOiltech LOC 044-4-A-COiltech LOC 044-4-A-D

20204060802040405560802040405560804040556080556080556080

0,070,130,170,180,180,190,260,190,220,290,300,260,380,310,350,450,490,520,420,460,600,660,650,800,870,851,001,12

2,75,26,87,27,27,6

10,47,68,8

11,612,010,415,212,414,018,019,620,816,818,424,026,426,032,034,834,040,044,8

57646465657070616170707474646474747767677777748585778686

67737374747979707079798383737383838777778787849595879696

0,0580,290,290,290,290,610,610,370,370,610,610,960,960,580,580,960,961,500,920,921,501,501,522,412,411,892,992,99

4-0,754-0,754-0,754-1,504-1,504-0,754-0,756-1,106-1,104-1,504-1,504-1,504-1,506-1,106-1,104-1,504-1,504-1,506-1,106-1,504-2,204-2,206-2,204-3,004-3,006-2,204-3,004-3,00

200325325325325400400400400400400456456456456456456538538538538538650650650650650650

23303036363434404040404545454545455353536262927676988585

Data at 50 Hz

4

Page 5: LOC Tech

Example: LOC-011-6-A-C-L-50-S20-D-E-0

For further information and latest modifications, please enter our homesite www.oiltech.se. To facilitate selection of air oil cooler, order Oiltech's calculation programme.

When a special cooler is required, please specify product, components, performance, dimensions etc, in text en clair. Price and time of delivery available on request.

004 016 044007 023011 033

Displacement 15 cm3/r = ADisplacement 30 cm3/r = BDisplacement 45 cm3/r = CDisplacement 60 cm3/r = DSpecial = X

Without guard = 0Stone guard = SDust guard = DDust and stone guard = P

Standard = 0Special = Z

4-pole = 46-pole = 6

Ordering key for Oiltech LOC cooling system.When ordering every item should be specified.

LOC- X X X - X - X - X - X - X X - X X X - X - X - X1 2 3 4 5 6 7 8 9 10 11

2. Cooler size

Without by-pass valve = 0Built-in by-pass valve, 5 bar = LBuilt-in by-pass valve, 10 bar = H

6. By-pass valve, pump

4. Voltage and frequency

9. Matrix guard

11. Standard/special

3. Number of poles, motor

5. Pump size

Without thermo contact = 0040°C = 4050°C = 5060°C = 6070°C = 7080°C = 8090°C = 90

7. Thermo contact (For temperaturewarning. Not for electromotor control)

Standard = 000Two pass = T00Built-in, pressure controlled by-pass valve, single-pass

2 bar = S205 bar = S508 bar = S80Built-in, pressure controlled by-pass valve, two-pass*

2 bar = T205 bar = T508 bar = T80Built-in, temperature and pressure controlled by-pass, single-pass

50°C, 2,2 bar = S2560°C, 2,2 bar = S2670°C, 2,2 bar = S2790°C, 2,2 bar = S29Built-in, temperature and pressure controlled by-pass, two-pass*

50°C, 2,2 bar = T2560°C, 2,2 bar = T2670°C, 2,2 bar = T2790°C, 2,2 bar = T29

8. Cooler matrix

1. Cooling system with AC-motor and circulation pump = LOC

Three-phase, 230/400V, 50 Hz = AThree-phase, 275/480V, 60 Hz = BThree-phase, 230/400V 50 Hz, 275/480V 60 Hz = DThree-phase, 500V, 50 Hz = EThree-phase, 400/690V, 50 Hz = FMotor for special voltage (in text en clair) = X

10. Filter and filter housingWithout filter housing = 0 Filter housing, without filter cartridge = HFilter housing, filter cartridge 10 µm/visual indicator = VFilter housing, filter cartridge 10 µm/electrical indicator = E(filter housing adapted to DIN cartridges)

* Not available for Oiltech LOC 004

5