LMS/LMI 400 User Software - Umeå University info/SICK/ErgBALMSI400E.pdf · S UPPLEMENT TO THE...

12
S UPPLEMENT TO THE O PERATING I NSTRUCTIONS LMS/LMI 400 User Software New functions from Version 4.1 up to Version 5.1

Transcript of LMS/LMI 400 User Software - Umeå University info/SICK/ErgBALMSI400E.pdf · S UPPLEMENT TO THE...

Page 1: LMS/LMI 400 User Software - Umeå University info/SICK/ErgBALMSI400E.pdf · S UPPLEMENT TO THE O PERATING I NSTRUCTIONS LMS/LMI 400 User Software New functions from Version 4.1

SU

PP

LE

ME

NT

T

O

TH

E

OP

ER

AT

IN

G

IN

ST

RU

CT

IO

NS

L M S / L M I 4 0 0U s e r S o f t w a r e

N e w f u n c t i o n s f r o mV e r s i o n 4 . 1 u p t o V e r s i o n 5 . 1

Page 2: LMS/LMI 400 User Software - Umeå University info/SICK/ErgBALMSI400E.pdf · S UPPLEMENT TO THE O PERATING I NSTRUCTIONS LMS/LMI 400 User Software New functions from Version 4.1

Supplement to the OI

LMS/LMI 400 User Software

Contents1 Common changes .................................................................................................................3

1.1 Translating to 32-Bit............................................................................................................ 3

1.2 Change of fields.................................................................................................................... 3

2 New LMS type ........................................................................................................................42.1 New LMS type “LMS special type 90°/0.5°“ ............................................................ 4

3 “LMS-CONFIGURATION“ menue .............................................................................................53.1 New: Real time indices....................................................................................................... 5

3.2 New: Contour on plain........................................................................................................ 6

3.3 Available levels...................................................................................................................... 8

4 Teach-In ....................................................................................................................................94.1 Automatic Teach-In.............................................................................................................. 9

4.2 Teach-In ................................................................................................................................... 9

5 “SICK DIAGNOSIS“ menue .................................................................................................. 105.1 New: Operating and switch-on counter .................................................................... 10

5.2 New telegram: Examining all logical levels of the output ................................... 11

Windows 95TM/98TM and Windows NTTM/2000TM are registered trademarks or trademarks

of the Microsoft Corporation in the USA and other countries.

2 © SICK AG · Division Auto Ident · Germany · All rights reserved 8 010 121/M814/18-10-2002

Page 3: LMS/LMI 400 User Software - Umeå University info/SICK/ErgBALMSI400E.pdf · S UPPLEMENT TO THE O PERATING I NSTRUCTIONS LMS/LMI 400 User Software New functions from Version 4.1

Supplement to the OI Chapter 1

LMS/LMI 400 User Software

Common changes

1 Common changes

1.1 Translating to 32-Bit

The User software has been translated into a 32 Bit version. A operating system WIN 95TM

or higher is required. The advantages are:

• Long file names possible

• Firmware downloads are possible with WIN-NTTM systems

• Using WIN-NTTM it is no longer necessary to change the process prioraty.

• 32- Bit Programs are faster on 32-Bit Operating Systems.

• In case of a program crash 32-Bit programs are easier to handle from the operating

system.

• The program has the look and feel of a 32-Bit Program

• Multiple instances of the program are possible therefore multiple devices can be

connected over different ports simulitaneously.

• Smoother communications.

• Win 9XTM allows parallel use of other programs.

1.2 Change of fields

Editing the fields can be facillated by using the mouse to ’Click & Drag’ thus creating a

rectangular selection area. All field points are thereby selected at once.

8 010 121/M814/18-10-2002 © SICK AG · Division Auto Ident · Germany · All rights reserved 3

Page 4: LMS/LMI 400 User Software - Umeå University info/SICK/ErgBALMSI400E.pdf · S UPPLEMENT TO THE O PERATING I NSTRUCTIONS LMS/LMI 400 User Software New functions from Version 4.1

Chapter 2 Supplement to the OI

LMS/LMI 400 User Software

New LMS type

2 New LMS type

2.1 New LMS type “LMS special type 90°/0.5°“

The LMS IBS supports the version LMS Special 90°/0,5°. The sensor has a 90° view and a

0,5 ° angular resolution. For one scan 13.32 ms are needed.

In the LMS IBS the sensor is described by "LMS special type 90°/0.5° configuration"

When this sensor is selected all menu items inclusive to LMS Type 6 and all menu items and

functions relating to field evaluation are deactivated. The assistant is not available with this

selection.

For this device type there are only three tabs (Sensor , In-/Outputs, Extras) avaiable in the

’Configuration’ window (LMS → Configuration → Edit).

Under the Sensor tab only the type of sensor is displayed and can not be changed.

Under the list item MEASUREMENT MODE the user is able to define how many bits are used for

the measurement value.

• 13 bits for the measurement range of 8/80 meter

• 14 bits for the measurement range of 16/160 meter

• 15 bits for the measurement range of 32/320 meter

This sensor does not have flags.

4 © SICK AG · Division Auto Ident · Germany · All rights reserved 8 010 121/M814/18-10-2002

Page 5: LMS/LMI 400 User Software - Umeå University info/SICK/ErgBALMSI400E.pdf · S UPPLEMENT TO THE O PERATING I NSTRUCTIONS LMS/LMI 400 User Software New functions from Version 4.1

Supplement to the OI Chapter 3

LMS/LMI 400 User Software

“LMS-CONFIGURATION“ menue

The tab IN-/OUTPUTS replaced tab RESTART of the standard sensors. Under this tab only the

master-slave functionality can be configured since the special sensor type does not support

field applications.

Under the EXTRAS the parameters are the same as those for the standard sensor.

3 “LMS-CONFIGURATION“ menue

3.1 New: Real time indices

LMS → CONFIGURATION → EDIT → SENSOR

It is possible to send indices for scans and transmitted telegrams with the request for the

measurement values. There is no further influence on the LMSIBS user software.

8 010 121/M814/18-10-2002 © SICK AG · Division Auto Ident · Germany · All rights reserved 5

Page 6: LMS/LMI 400 User Software - Umeå University info/SICK/ErgBALMSI400E.pdf · S UPPLEMENT TO THE O PERATING I NSTRUCTIONS LMS/LMI 400 User Software New functions from Version 4.1

Chapter 3 Supplement to the OI

LMS/LMI 400 User Software

“LMS-CONFIGURATION“ menue

3.2 New: Contour on plain

LMS → CONFIGURATION → EDIT → CONTOUR

For the outdoor devices LMS 211/221/291 there is an additional function for CONTOUR AS

REFERENCE avaiable.

Most reference contours are straight. To get a parallel contour band around a straight plane

the function CONTOUR AS REFERENCE has been expanded with the option CONTOUR ON PLANE.

The function used in the past was RADIAL.

Attention!

The laser scanners LMS 200/220 only accept RADIAL

Pitch angle

If the option CONTOUR ON PLAIN is selected there is (under SETTINGS) the possibility to set the

angle at which the LMS is installed relative to reference plane. 0° means the scanner back

plane is parallel to the reference plane. The angle is the so called ’pitch angle’. The pitch

angle is selectable between + 90° and - 90°. Note that the LMS scanner is scanning

counterclockwise. Every scan beam has a defined angle to the back plane. The 90° scan

beam is perpendicular to the back plane of the LMS. At a pitch angle of 0° the 90° scan

beam is perpendicular to the reference plane.

At +10° pitch angle of the scanner (scan is counter clockwise top view) the 80° scan beam

is the new perpendicular to the reference plane.

6 © SICK AG · Division Auto Ident · Germany · All rights reserved 8 010 121/M814/18-10-2002

Page 7: LMS/LMI 400 User Software - Umeå University info/SICK/ErgBALMSI400E.pdf · S UPPLEMENT TO THE O PERATING I NSTRUCTIONS LMS/LMI 400 User Software New functions from Version 4.1

Supplement to the OI Chapter 3

LMS/LMI 400 User Software

“LMS-CONFIGURATION“ menue

The function CONTOUR AS REFERENCE should only be used if the working angle around the

perpendicular to the contour plane stays within + 70° and - 70°.

As a example:

• Pitch Angle 0° creates a maximum start angle for contour as reference of 20° and a stop

angle of 160°• Pitch Angle 10° creates a maximum start angle for contour as reference of 10° and a

stop angle of 150°• Pitch Angle -10° creates a maximum start angle for contour as reference of 30° and a

stop angle of 170°Since this function is not available on the scanners LMS 200/220 the pitch angle must be

set to 0°.

8 010 121/M814/18-10-2002 © SICK AG · Division Auto Ident · Germany · All rights reserved 7

Page 8: LMS/LMI 400 User Software - Umeå University info/SICK/ErgBALMSI400E.pdf · S UPPLEMENT TO THE O PERATING I NSTRUCTIONS LMS/LMI 400 User Software New functions from Version 4.1

Chapter 3 Supplement to the OI

LMS/LMI 400 User Software

“LMS-CONFIGURATION“ menue

3.3 Available levels

LMS → CONFIGURATION → EDIT → EXTRAS

In this window the available levels can be selected. These levels implement, among other

things, the response to dazzling.

Dazzling explaned: Scanners of the LMS series work on the pulse travelling time with an emitting light source of

905 nm. Direct exposure to sun light or similar light sources leads to dazzling at a certain

angle. There is no measurement possible by a dazzled beam. The dazzled beam is marked

in the scanner.

The factory settings of all LMS scanners are at Level 1.

3.3.1 Availability level 1

Level 1 indicates that a dazzled beam is interpreted as a field infringement.

The dazzling is temporarily ignored until the number of scans, specified by MAXIMUM DURATION

OF DAZZLING is reached at which point a field infringement is reported. Within the input window

the user can set the number of scans required to activate this level. A scan is 13.32 ms.

1 to 255 scans can be selected. (13.32 ms to 3.4 s). Default is 2 scans.

3.3.2 Availability level 2

Level 2 indicates that a dazzled beam does not affect the field functionality. The beam is

ignored.

3.3.3 Availability level 3

Level 3 is not related to dazzling. It is related the previously delivered LMS hardware (Typ

1-5). These are devices that can not be delivered anymore and are replaced by type 6

scanners. Since the LMS scanners are regularly upgraded some parameters have different

defaults. To assure full compatibility to types 1-5 scanners this menu point can be selected.

If selected the differences are:

• During regular self testing of the scanners the dazzling results in an info message instead

an error.

• The contamination level is set to be active at 50% instead of 25%

• An error in the reference channels for contamination results in an info message instead

an error.

• The detection of oil contamination results in an info message instead a warning/error.

• At the loss of synchronization with a slave configuration of the LMS scanner results in an

info message instead an error.

8 © SICK AG · Division Auto Ident · Germany · All rights reserved 8 010 121/M814/18-10-2002

Page 9: LMS/LMI 400 User Software - Umeå University info/SICK/ErgBALMSI400E.pdf · S UPPLEMENT TO THE O PERATING I NSTRUCTIONS LMS/LMI 400 User Software New functions from Version 4.1

Supplement to the OI Chapter 4

LMS/LMI 400 User Software

Teach-In

4 Teach-In

4.1 Automatic Teach-In

LMS → MONITORED FIELD → TEACH-IN (F5)

For automatic teach-in of fields a separate window gives the possibility to set a specified

distance between the defined field borders and the reference. The field is made shorter than

the given distance. The default is 70mm. Values between 50 and 400 mm can be selected.

4.2 Teach-In

LMS → MONITORED FIELD → REFLECTOR TEACH-IN (F5)

or with the quick button in the tool bar

8 010 121/M814/18-10-2002 © SICK AG · Division Auto Ident · Germany · All rights reserved 9

Page 10: LMS/LMI 400 User Software - Umeå University info/SICK/ErgBALMSI400E.pdf · S UPPLEMENT TO THE O PERATING I NSTRUCTIONS LMS/LMI 400 User Software New functions from Version 4.1

Chapter 5 Supplement to the OI

LMS/LMI 400 User Software

“SICK DIAGNOSIS“ menue

If reflectors are placed at the corners of fields which have to be created those reflectors can

be used for automatic field teach in.

With the TEACH-IN WITH REFLECTORS Field A and B are always created simultaneously. For

every field taught in a contour as reference will be defined at the end.

If the LMS Sensor is a LMS 200/220 and a pixel orientated evaluation is selected it will be

reconfigured to scan oriented evaluation with the appropriate message.

Attention:

The function teach in by reflectors is only possible with the 100° view. If the LMS sensor is

configured as a 180 ° view device it will be automaticaly reconfigured with the appropriate

message.

5 “SICK DIAGNOSIS“ menue

5.1 New: Operating and switch-on counter

MEASUREMENT TECHNIQUE → SICK DIAGNOSIS

10 © SICK AG · Division Auto Ident · Germany · All rights reserved 8 010 121/M814/18-10-2002

Page 11: LMS/LMI 400 User Software - Umeå University info/SICK/ErgBALMSI400E.pdf · S UPPLEMENT TO THE O PERATING I NSTRUCTIONS LMS/LMI 400 User Software New functions from Version 4.1

Supplement to the OI Chapter 5

LMS/LMI 400 User Software

“SICK DIAGNOSIS“ menue

The LMS 211/221/291 are equipped with an operating counter and a switch-on counter.

Every ’switch-on’ is documented. The operating counter is triggered every two hours.

5.2 New telegram: Examining all logical levels of the output

MEASUREMENT TECHNIQUE → SICK DIAGNOSIS

By selecting the telegram 'REQUEST FOR STATE OF FIELD OUTPUTS' all logical levels of the output

can be examined.

8 010 121/M814/18-10-2002 © SICK AG · Division Auto Ident · Germany · All rights reserved 11

Page 12: LMS/LMI 400 User Software - Umeå University info/SICK/ErgBALMSI400E.pdf · S UPPLEMENT TO THE O PERATING I NSTRUCTIONS LMS/LMI 400 User Software New functions from Version 4.1

SICK AG · Auto Ident · Nimburger Straße 11 · 79276 Reute · Germany · www.sick.com8 0

10

12

1/M

81

4/1

8-1

0-2

00

2 · 5

M/T

R <

FM

5.5

> · S

MD

· P

rinte

d in G

erm

any

· S

ub

ject

to c

hange

witho

ut

prio

r no

tice

· A

ftE

37

05

sw

A u s t r a l i aPhone +61 3 9497 4100

(0 08) 33 48 02–toll free

Fax +61 3 9497 1187

A u s t r i aPhone +43 22 36/62 28 8-0

Fax +43 22 36/62 28 85

B e l g i u m / L u x e m b o u r gPhone +32 24 66 55 66

Fax +32 24 63 31 04

B r a z i lPhone +55 11 5561 2683

Fax +55 11 5535 4153

C h i n aPhone +85 2 2763 6966

Fax +85 2 2763 6311

C z e c h R e p u b l i cPhone +42 02-579 11 850

+42 02-578 10 561

Fax +42 02-578 10 559

D e n m a r kPhone +45 45 82 64 00

Fax +45 45 82 64 01

F i n l a n dPhone +358 9-728 85 00

Fax +358 9-72 88 50 55

F r a n c ePhone +33 1 64 62 35 00

Fax +33 1 64 62 35 77

G e r m a n yPhone (+49 2 11) 53 01-0

Fax (+49 2 11) 53 01-1 00

G r e a t B r i t a i nPhone +44 17 27-83 11 21

Fax +44 17 27-85 67 67

I t a l yPhone +39 02-92 14 20 62

Fax +39 02-92 14 20 67

J a p a nPhone +81 3 3358 1341

Fax +81 3 3358 0586

K o r e aPhone +82 2 786 6321/4

Fax +82 2 786 6325

N e t h e r l a n d sPhone +31 30 229 25 44

Fax +31 30 229 39 94

N o r w a y

Phone +47 67 56 7500

Fax +47 67 56 6100

P o l a n dPhone +48 22 837 40 50

Fax +48 22 837 43 88

S i n g a p o r ePhone +65 67 44 37 32

Fax +65 68 41 77 47

S p a i nPhone +34 93 4 80 31 00

Fax +34 93 4 73 44 69

S w e d e nPhone +46 8-680 64 50

Fax +46 8-710 18 75

S w i t z e r l a n dPhone +41 41 61 92 93 9

Fax +41 41 61 92 92 1

T a i w a nPhone +886 2 2365-6292

Fax +886 2 2368-7397

U S APhone +1(781) 302-2500

Fax +1(781) 828-3150

Representatives and agencies in

all major industrial countries.