REVOLUTION IN THE DATA CENTERMOVING FROM AIR COOLING TO LIQUID COOLING
Proprietary & Confidential 2016, LiquidCool Solutions, Inc.
LiquidCool Solutions: the market leader!
» Rich and deep history of starting the liquid submersion cooling movement
» World’s first commercially available liquid submersion computing platforms
» Over 40 patents around submersion cooling
» The only company to make submersion cooling practical, scalable & award winning
2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015
Efficient Server Power
On-Board UPS
Carbon Neutral
Warehouse Scale Datacenter
Containerized Datacenter
First Public PUE Reporting
Facebook Open Compute Project
Free Air Cooling
The Evolution of LiquidCool Solutions
Hardcore Computer, Inc.
Founded
Hardcore Computer becomes
LiquidCool
Worlds First Submersion Desktop PC“Reactor”
Worlds First Submersion Workstation“Detonator”
Worlds First Submersion Rack Server
“LSS”
Worlds First Submersion Data Center
Module
Cloud Computing Consolidation
Wells Fargo Invests
Intel Partnership
Rugged Tier Computing
TROPEC Validation
Core Coolant
Developed40 patentsLiquidCool Solutions Milestones
Market Milestones
IBM 2 Phase Cooling
Google Dataflow
NREL Validation
Over the past 10+ years LiquidCool has builtthe most energy efficient, cost effective and
practical approach to data center cooling
Fans are the problem
Fans Waste Energy
• 15% of total datacenter energy is used to move air
• Fans in the chassis can use up to 20% of power at the device level
• Fans are inefficient and generate heat that must be removed
Fans Waste Space
• Racks need room to breathe
• CRAC units require space around the racks
Fans Reduce Reliability
• Fans fail
• Thermal fluctuations drive solder joint failures
• Vibration frets electrical contacts
• Fans expose electronics to air • Oxidation/corrosion of electrical contacts• Sensitivity to ambient particulate, humidity
and temperature conditions
Air is an insulator, not a coolant
» Cooling with Air is Expensive
» Air Cooling Wastes Space
» Air Cooling Limits Power Density
» Air Cooling Reduces Reliability
• Fans Fail
• Air Causes Oxidation and Corrosion
• Air Enables Large Temperature Swings
» Air Cooling Wastes Energy
• Up to 15% of Total Power is used to Move Air• Up to 20% More Power is used by Rack Fans• Fans Generate Heat that must be Dissipated
LiquidCool’s Elegant Solution
Total liquid immersion in a eco-friendly dielectric fluid
• “Cool” liquid is circulated directly to hottest components first. Remaining components are cooled by bulk flow as the dielectric liquid exits the chassis.
• Directed flow is a key differentiator
• No fans or other moving parts in the chassis
• Rack-mounted devices are easy to maintain
• Off-the-Shelf Components
Up to 125°F
Up to 110°F
No Moving Parts – Flow Rate: 0.25 gal / min
20 GRANTED PATENTS
20 PATENTS PENDING
LCS Cooling System Elements
• Pump supplies “cool” dielectric liquid to multiple IT racks
• If there is no energy recycling option, “hot” fluid is circulated to an evaporative fluid cooler
• Incoming “cool” fluid can be as warm as 110oF for most applications, which completely eliminates the need to use water almost anywhere in the world
Cooling Without Water
Saves Space
(1) 25kW 42U Rack64, 400W ServersCan Go Anywhere
4-8kW 42U Racks156-200W Servers (7kW for onboard fans)
Needs an Air Conditioned Room
Air Cooled
Eliminate Costly Infrastructure
What LCS Does Not Need
• Mechanical Refrigeration
• Cooling Towers
• Air Handlers
• Humidity Control
• Blade and Rack Fans
• Mixing Dampers
• High Ceilings
• Hot Aisles
• Noise
• Water
• Very much space
Facebook Data Center after LCS
LCS saves Facebook (MILLIONS)
» LCS eliminates the need for a 3 story building
» LCS uses a fraction of the floor space
» LCS eliminates 1.4 million cubic feet of air per minute
» LCS eliminates DX units for dehumidification when indoor RH exceeds 85%
» LCS eliminates evaporative cooling when outdoor temperature is over 85°F
» LCS saves not only upfront capex but also the energy to run the facility
LCS eliminates all of that!
A Custom Solution for Facebook
LCS custom server for Facebook
» Modified OCP Rack w/ 7 Processors and 14 Storage Servers
» Ultra, ultra high-density enclosure
» Proprietary cooling for spindle drive bays and in-rack storage
LiquidCool Clamshell Server
3rd Party Validation
Lawrence Berkeley National Laboratory
• Lawrence Berkeley National Laboratory assessed LiquidCool technology for the US Navy’s Transformative Reductions in Operational Energy Consumption (TROPEC) program for continuous operation of servers and communication/network equipment in tropical environments with no mechanical cooling.
• The Coefficient of Performance for the LCS system was 49.9 at full load compared to 1.6 for current practice, 30 times better.
National Renewable Energy Laboratory• Preliminary data from the testing program, currently underway, suggest that more than 85% of
the electric energy used by LCS servers can be recycled to create hot water for building heat.
• The test program will conclude in November at which time the LCS rack and servers will be moved to NREL’s high performance computing center.
Intel Corporation• Confirmed that the LCS dielectric fluid does not have a deleterious effect on Intel processors,
and all processor cores and memory operated well within the normal operating range even at coolant temperatures of 122°F
• As a result of this study and other investigations it undertook, Intel committed to extend normal warranty terms to processors immersed in the dielectric fluid LCS employs.
Competition
Three Liquid Cooling Technologies:1. Cold Plates – Requires Fans
– Shifts heat from processors but does not save much energy– Mechanical cooling needed above 85oF– Maximum rack density is 30-kilowatts
2. In-Row Cooling – Requires Fans– Makes the room smaller – Mechanical cooling above 80oF– Maximum rack density is 35-kilowatts
3. Total Immersion in a Dielectric Fluid – No Fans; > 75kW rack densityGreen Revolution CoolingIceotope
3M (Allied Control and SGI)
LiquidCool Solutions
The LiquidCool Advantages
LiquidCool Can Have Any Shape or Size Green Revolution, Iceotope, 3M
LiquidCool Requires No Water in Datacenter Iceotope, 3M
LiquidCool Scales vertically or horizontallyGreen Revolution, 3M
LiquidCool is Easy to Swap & Maintain Devices Green Revolution, Iceotope, 3M
LiquidCool Has Harsh Environment Deployments Green Revolution, 3M
LiquidCool is on Par With Air Cooling (Low Cost)Iceotope, 3M
Customer InstallationsLiquid Submerged Server Rack
• University of Minnesota Supercomputing Institute• Microsoft Technology Center - Minneapolis• Dedicated Computing• National Renewable Energy Laboratory
Rugged Terrain Computer (started shipping in August, 2015)Installed• JBS Tannery• George Washington University• Stanford SLAC National Accelerator Laboratory• Colorado Judicial Courts• Brookdale Health
Scheduled• CISCO Systems• MITRE• CoreFocus• United Healthcare• Wisconsin Electric
Product Mix
Rugged Terrain Computer (RT)High performance computer that is ideal for factory floors, construction sites, etc.
Manufactured by Dedicated Computing.
Liquid Submerged Server (LSS Rack)
High density, easy to maintain, Cooling PUE<1.02
Manufactured by Dedicated Computing.
Explorer
Rugged, mobile 4kW compute system that is ideal for field data processing
Three heat rejection options
Manufactured by Dedicated Computing
Clamshell ServerLow cost Open Compute Project servers for cloud datacenters
Manufactured by Herold Precision Metals
200 Kilowatt Prefabricated Module (PFM)
Unique computing appliance that can be transported by cargo plane
Johnson Controls is the module manufacturer and project integrator
750 Kilowatt PFMUnique computing appliance that replaces five air-cooled PFMs
Johnson Controls is the module manufacturer and project integrator
LSC-RT Rugged Terrain Computer
LSC-RT features:
• Internal High-Efficiency Pump
• Sealed and fanless system
• IP67-rated I/O and Power
connections
• Supports Intel Core-i3/i5/i7 CPUs
up to 84W
• Operating temperature range:
10°F - 110°F
• Dual Passive Radiators
• USB 2.0, HDMI, 1Gb Ethernet
ports
Explorer Server Rack
LCS Explorer: 8 or 16 High-performance servers in a modular configuration of shock-isolating rack cases
•
•
•
•
•
•
•
•
•
•
Redundant 8kW CDUs
Room for rugged switch and storage
8X LSS Servers
Battlefield Tested and Ready
LiquidCool Solutions Participated In Joint Military Exercises at Emerald Warrior 2015
LSS Rack
Markets: Greenfield and Datacenter Retrofits, Prefabricated IT Modules
Features:
• 36-kilowatt rack, equivalent to four air-cooled racks
• Electronics protected from humidity, dust, oxidation, and corrosive gases
• Energy Efficient Cooling PUE<1.02
• Scalable
• Easy to Maintain
• No Moving Parts
• No Water
Modular Data Centers
Global Modular Datacenter Market Expected to Grow from $8.37 Billion in 2015 to $35.11 Billion by 2020 at a CAGR of 33.2%
--- Research and Markets Organization 6/25/15
LiquidCool Clamshell Rack
Target Market: Cloud Datacenters
Features:
• Up to 75-kW and 120 servers per rack
• Open Compute Project architecture
• Power and I/O outside the wet area
• Energy Efficient – Cooling PUE<1.03
• No water
• Easy to Maintain
• No Moving Parts
LiquidCool 200-Kilowatt Modular Data Center
Markets: Temporary Deployments, Military, Catastrophic Weather Events, Filmmaking
Features:
• 200-kilowatt Prefabricated Module designed to be transported by cargo plane
• Rapid field set up
• Energy Efficient – Cooling PUE<1.03
• No water
• Easy to Maintain
• Electronics protected from humidity, dust, oxidation, and corrosive gases
Overall dimensions: 12’ x 12’ x 20’
LiquidCool 750-KW Prefabricated Module
Overall dimensions: 12’ x 12’ x 42’
Markets: Enterprise Datacenters, Research
Features:
• Replaces four air-cooled modules
• Energy Efficient – Cooling PUE<1.03
• No water
• Easy to Maintain
• No Moving Parts
• Electronics protected from humidity, dust, oxidation, and corrosive gases
Data Center Energy Savings
• In a typical datacenter, roughly 38% of energy costs go to HVAC cooling and fans
(ASHRAE and DOE, 2012)
• Using LiquidCool technology, fans in devices are eliminated and the need for HVAC cooling and fans is greatly reduced
• As a result, datacenter energy costs can be reduced by 50%or more by using LiquidCool technology
The Largest Liquid Cooling Patent Portfolio
20 Issued Patents
• Liquid tight server case with dielectric liquid for cooling electronics
• Extruded server case used with liquid coolant of electronics
• Computer with fluid inlets and outlets for direct-contact liquid cooling
• Case and rack system for liquid submersion cooling of an array of electronic components
• Computer case for liquid submersion cooled components
• Liquid submersion cooled computer with directed flow
• Gravity assisted directed liquid cooling
20 Additional Patents Pending
Executive Team
38
• Herb Zien (CEO) who has over 30 years of experience in project development, engineering management, power generation and energy conservation. He was co-founder of a firm that grew to become the largest owner and operator of District Energy Systems in the U.S.
• Rick Tufty (VP Engineering) who is an experienced executive having worked for Dell, Maxtor, HP and IBM. He holds 11 U.S. and international patents.
• David Roe (Program Manager) who has over 20 years of technical development experience and is an expert in computer and cooling technologies.
• Daren Klum (co-Founder) who is an experienced executive with 15 years building industry leading technology products and bringing them to market. Experience includes product strategy, software, hardware development and executive leadership.
• Stephen Einhorn (Chairman) who is a partner at Capital Midwest Fund, the largest shareholder.
Stephen Einhorn
414-453-4488
David Roe, Program Manager
507-250-4727
Herb Zien, CEO
414-289-7171
Rick Tufty, VP Engineering
507-535-5829
Daren Klum, Co-Founder
651-324-4440