LEGEND AND SYMBOLS - Iowa Communications Network · UNIQUE SYMBOLS FOR THIS ......
Transcript of LEGEND AND SYMBOLS - Iowa Communications Network · UNIQUE SYMBOLS FOR THIS ......
EXISTING PROPOSED DESCRIPTIONS
UNIQUE SYMBOLS FOR THIS PROJECT
ICN Bored Conduit
ICN Handhole
LP Locate Point
Existing Conduit
R/W
CL
P/L
EOP
EOC
C.S.W.
B.O.C.
G
STM
SS
TELE
W
TELFSSSTM
21
SPLICE-W/LOC. STATION
FIBER CHANGE (BID & CONST. ISSUE)
CASING PIPE
(GALV. IRON PIPE) G.I.P.
RIGHT-OF-WAY LINE(phantom linetype)
CENTER LINE(center linetype)
FENCE LINE
PROPERTY LINE
EDGE OF PAVEMENT
EDGE OF CONCRETE
CITY, COUNTY OR STATE BOUNDARY
BACK OF CURB
CONCRETE SIDEWALK
GAS LINE
STORM SEWER
SANITARY SEWER
TELEPHONE LINE
WATER LINE
POLE
POLE W/ANCHOR
TILE INTAKE
MILE POST MARKER
CULVERT
BRIDGE
TREE & VEGETATION
STREET SIGN
FIRE HYDRANT
STREET LIGHT
MANHOLES
LEGEND AND SYMBOLS
UNDERGROUND
ELECTRIC
ELEC
ROUTE MARKERS
(PVC OR STEEL)
R/RREMOVE & REPLACE
F/LFLOW LINE
C/RCUT & REPLACE
SUBSURFACE DRAIN TILE
DITCH LINE D/L
S TL,
UGE
BT
,
,
ICN CABLE SEQUENCE NUMBER (SEQ.#12345)
ICN MKR
12+34
)
UTILITY PEDESTAL
WATER METER
GAS METER
GAS MARKER
TELEPHONE MARKER
R/W MARKER
DRAIN
RAILROAD SIGNAL/SIGN
OVERHEAD ELEC. OHE
SECTION MARKER
EDGE OF GRAVEL EOG
R
SECTION LINE
GROUND
MAILBOX
TEMP. EASEMENT
GROUND ROD
EO
H
EO
H
MSXXX-A
---
SPLICE
---
EO
C
EO
C
---
---
#F #F
LP
12
3 4
SPLICE-NO LOC. STATION
EO
H
EO
H
MS702B-A
00000
SPLICE
00000
EO
C
EO
C
00000
00000
#F #F
ABBREVIATIONS
ROW Right of Way
HH Handhole
ICN Iowa Communications Network
NTS Not to Scale
NEC
DOT Department of Transportation
National Electric Code
TCP Traffic Control Plan
LOCATION SERVICES.UTILITIES AND LOCAL GOVERNMENT AGENCIES NOT PARTICIPATING IN UTILITIES. THE CONTRACTOR SHALL ALSO CONTACT ANY AND ALL LOCATOR SERVICES AND SCHEDULING THE LOCATION OF UNDERGROUND CONTRACTOR SHALL BE RESPONSIBLE FOR CONTRACTING UTILITIES AND SHALL BE LOCATED AND MARKED PRIOR TO CONSTRUCTION. THE OF UTILITY INFORMATION MAY NOT HAVE BEEN PROVIDED. ALL UTILITIES WHEN SHOWN, ARE APPROXIMATE ONLY. IN ADDITION, A PORTION NOTE: THE PLAN LOCATIONS OF UNDERGROUND AND AERIAL UTILITIES,
LEGEND AND SYMBOL INFORMATION SHEET
A.02gehrhorn9:31:28 AM 7/10/2017 gehrhorn9:31:28 AM 7/10/2017
7/11/2017
11 x 17SCALE: SIZE:
GRIMES STATE OFFICE BUILDING
ICN C , COPY WITH PERMISSION
IOWA COMMUNICATIONS NETWORK
2014
DES MOINES, IOWA 50319
400 EAST 14TH STREET
THIS DRAWING IS PROVIDED FOR GENERAL
INFORMATION ONLY AND IS NOT TO BE USED
TO DETERMINE PRECISE ICN PLACEMENT.
CALL ONE CALL BEFORE EXCAVATION
(1-800-292-8989 OR 811)F:\2016\0501-1000\016-0760\40-Design\Microstation\016-0760_Grinnell College Connection\Sheets\Cover_02.dgn
GRINNELL COLLEGE CONNECTION
GRINNELL, IA
Sheet 11 x 17
OSP LOG #79160205
6/22/2017
FINAL
PRELIM
2
1
PROJECT DESCRIPTION
AND LISTING OF WORKESTIMATE OF QUANTITIES, PROJECT DESCRIPTION,
fiber cables, tracer wire, pull rope, etc. Contractor shall verify necessary quantities including coils.
*NOTE: This table shows approximate lengths in conduit only and does not include any coils or slack for
C.01
AND DATA TRAFFIC CUTOVERS WILL BE COMPLETED UNDER A SEPARATE CONTRACT.
APPROXIMATELY 150 FEET IN THE BASEMENT OF THE JOHN CHRYSTAL CENTER. FIBER SPLICING
CONDUIT. INSIDE WORK WILL INVOLVE INSTALLING FIBER IN AN EXISTING CABLE TRAY
CONDUIT WILL BE INSTALLED, WHICH WILL CONSIST OF DIRECTIONAL BORING (1) 2" HDPE
CENTER AT 1103 PARK ST., GRINNELL, IA. APPROXIMATELY 4,957 FEET OF UNDERGROUND
FROM THE GRINNELL HIGH SCHOOL AT 1333 SUNSET ST., GRINNELL, IA TO JOHN CHRYSTAL
THIS PROJECT INVOLVES INSTALLING A 12 STRAND ARMORED FIBER CONNECTION
ICN PROVIDING NEW FIBER OPTIC TO GRINNELL COLLEGE.
ICN FIBER OPTIC INSTALLATION PROJECT IN POWESHIEK COUNTY.
PROJECT SUMMARY
SHEET NUMBER ENGLISH ICN
gseib9:21:20 AM 7/11/2017 gseib9:21:20 AM 7/11/2017
7/11/2017
11 x 17SCALE: SIZE:
GRIMES STATE OFFICE BUILDING
ICN C , COPY WITH PERMISSION
IOWA COMMUNICATIONS NETWORK
2014
DES MOINES, IOWA 50319
400 EAST 14TH STREET
THIS DRAWING IS PROVIDED FOR GENERAL
INFORMATION ONLY AND IS NOT TO BE USED
TO DETERMINE PRECISE ICN PLACEMENT.
CALL ONE CALL BEFORE EXCAVATION
(1-800-292-8989 OR 811)F:\2016\0501-1000\016-0760\40-Design\Microstation\016-0760_Grinnell College Connection\Sheets\General Notes.dgn
GRINNELL COLLEGE CONNECTION
GRINNELL, IA
Sheet 11 x 17
OSP LOG #79160205
6/22/2017
FINAL
PRELIM
2
1
GENERAL NOTES
GENERAL NOTES GENERAL NOTES
SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION.
3. THE RIGHT-OF-WAY, WHERE SHOWN ON PLANS, IS APPROXIMATE ONLY. RIGHT-OF-WAY
DURING CONSTRUCTION UNLESS OTHERWISE DIRECTED BY THE ENGINEER.
CONTRACTOR SHALL MAINTAIN AND PROTECT ALL EXISTING COMMUNICATION CABLES
2. ALL EXISTING IOWA COMMUNICATIONS NETWORK FIBER SHALL BE KEPT IN OPERATION.
MATCH EXISTING CONDITIONS.
1. AERIAL PHOTOGRAPHY SHOWN ON PLANS IS FOR REFERENCE ONLY AND MAY NOT
MISC.
STARTING CONSTRUCTION DATE.
WITHIN THE CONSTRUCTION LIMITS SHALL BE NOTIFIED BY THE CONTRACTOR OF THE
6. UTILITY COMPANIES WHOSE FACILITIES ARE SHOWN ON THE PLANS OR KNOWN TO BE
COORDINATING WITH IOWA COMMUNICATIONS NETWORK.
UTILITY COMPANY AND/OR OWNER. THE CONTRACTOR IS RESPONSIBLE FOR
AFFECTED BY THE EXISTING UTILITIES, THE WORK SHALL BE COORDINATED WITH THE
DEFINED WITHIN THE SCOPE OF WORK FOR THIS CONTRACT. WHERE WORK AFFECTS OR IS
5. THE CONTRACTOR SHALL NOT DISTURB ANY EXISTING UTILITIES EXCEPT AS SPECIFICALLY
LOCAL GOVERNMENT AGENCIES NOT PARTICIPATING IN LOCATION SERVICES.
UTILITIES. THE CONTRACTOR SHALL ALSO CONTACT ANY AND ALL UTILITIES AND
UTILITIES AND LOCATOR SERVICES AND SCHEDULING THE LOCATION OF UNDERGROUND
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING
HAVE BEEN PROVIDED. ALL UTILITIES SHALL BE LOCATED AND MARKED PRIOR TO
APPROXIMATE ONLY. IN ADDITION, A PORTION OF UTILITY INFORMATION MAY NOT
4. THE PLAN LOCATIONS OF UNDERGROUND AND AERIAL UTILITIES, WHEN SHOWN, ARE
UTILITIES
DETAILS, AND STANDARDS WITHIN THE SCOPE OF WORK BID DOCUMENT.
CONTRACTOR SHALL ADHERE TO ICN STANDARD INSTALLATION DRAWING TYPICALS, PROJECT
ICN STANDARDS:
WILL BE SUBJECT TO THE APPROVAL OF THE RESIDENT CONSTRUCTION ENGINEER.
AREAS FOR STORAGE OF MATERIALS. STORAGE, PARKING AND SERVICE AREA(S)
PERMITTED TO PARK OR SERVICE VEHICLES AND EQUIPMENT OR USE THESE
TREES OUTSIDE THE CONSTRUCTION LIMITS. THE CONTRACTOR WILL NOT BE
15. THE CONTRACTOR SHALL NOT DISTURB DESIRABLE GRASS AREAS AND DESIRABLE
SPECIFICATIONS AND SPECIAL PROVISIONS.
FOR HIGHWAY AND BRIDGE CONSTRUCTION, SERIES 2015" PLUS CURRENT SUPPLEMENT
OF THE "IOWA DEPARTMENT OF TRANSPORTATION ENGLISH STANDARD SPECIFICATIONS
APPLICABLE SECTIONS INCLUDING BUT NOT LIMITED TO ARTICLES 2523 AND 2525,
14. MATERIALS AND CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF ALL
IN KIND BY THE CONTRACTOR, WITH NO ADDITIONAL COMPENSATION.
INFRASTRUCTURE REMOVED OR DAMAGED BY THE CONTRACTOR SHALL BE REPLACED
CONDUCTORS, OR OTHER FACILITIES DAMAGED DURING CONSTRUCTION. ALL EXISTING
13. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO REPAIR ANY EXISTING CONDUIT,
THE IOWA COMMUNICATIONS NETWORK.
CONDITIONS (OR BETTER) AS DIRECTED BY THE ENGINEER AT NO ADDITIONAL COST TO
TREES, GRASS, SOD, ETC., IF DAMAGED, SHALL BE RESTORED TO PRE-CONSTRUCTION
GUTTERS, WALKS, DRAINAGE DITCHES, CULVERTS, DRAIN TILES, EMBANKMENTS, SHRUBS,
12. ANY AND ALL IMPROVEMENTS SUCH AS ASPHALT OR CONCRETE PAVEMENTS, CURBS,
CONSTRUCTION
CONSTRUCTION (CONTINUED)
LABOR AVAILABLE ON A DAILY BASIS TO INSTALL AND MAINTAIN EROSION
CONTROL FEATURES ON THE PROJECT. THIS MAY INVOLVE SEEDING, SILT
FENCE, ROCK DITCH CHECKS, SILT BASINS, OR SILT DIKES.
NON-WORKING HOURS.
CONDUIT
SHALL BE A MINIMUM OF 48 INCHES UNLESS OTHERWISE SPECIFIED IN PLANS.
MANUFACTURER'S RECOMMENDATIONS FOR MINIMUM BENDING RADIUS.
FOAM.
9. ENTER ALL HANDHOLES, BOTH NEW AND EXISTING FROM THE BOTTOM.
10. THE MINIMUM BENDING RADIUS OF HDPE CONDUIT SHALL BE THE CONDUIT
11. PLUG CONDUITS IMMEDIATELY AFTER INSTALLATION WITH DUCT SEAL OR EXPANSION
1. THE METALLIC SHIELD OF THE ARMORED CABLE SHALL BE USED AS THE LOCATE WIRE.
ALL LOCATE FACILITIES AND WIRES IN PREPARATION FOR THE SPLICING CONTRACTOR)
(THE CONDUIT/CABLE INSTALLATION CONTRACTOR IS RESPONSIBLE FOR PLACEMENT OF
LOCATE FACILITIES
C.02
7. THE CONTRACTOR SHALL BORE ALL CONDUIT ON THIS PROJECT. DEPTH OF ALL BORES
8. ALL CONDUIT SHALL BE 2-INCH HDPE SDR 13.5 CONDUIT.
ROCK AND DEBRIS AND SHALL BE FOR THE ESTABLISHMENT OF
VEGETATION, SUBJECT TO THE APPROVAL OF THE ENGINEER.
16. FILL ALL POTHOLES IMMEDIATELY AFTER THE DEPTH OF THE UTILITY IS DETERMINED.
WITH TOPSOIL AS SPECIFIED BELOW. COMPACT TO ENSURE SETTLING DOES NOT OCCUR.
FILL THE POTHOLE WITH SAND UP TO SIX (6) INCHES BELOW GRADE. FILL THE TOP 6 INCHES
17. THE TOP SIX (6) INCHES OF THE DISTURBED AREAS SHALL BE FREE OF
18. THE CONTRACTOR IS EXPECTED TO HAVE MATERIALS, EQUIPMENT, AND
THE IOWA COMMUNICATIONS NETWORK.
BE REPLACED OR REPAIRED, AS DIRECTED BY THE ENGINEER, AT NO ADDITIONAL COST TO
24. ANY EXISTING WIRING THAT IS DAMAGED DURING FIBER OPTIC CABLE INSTALLTION SHALL
DETERMINED BY THE ENGINEER.
FUTURE OPERATIONS OF THE COMPLETED FIBER OPTIC COMMUNICATION SYSTEM AS
BE ANY CONDITION RESULTING IN A NEGATIVE OR ADVERSE EFFECT ON CURRENT OR
ADDITIONAL COST TO THE IOWA COMMUNICATIONS NETWORK. CONSIDER A DEFECT TO
23. CONTRACTOR SHALL REPAIR OR REPLACE ANY DEFECT IN THE INSTALLED CABLE AT NO
OF TIME FOR DELAYS CAUSED BY REPLACING OR REPAIRING THE INSTALLED CABLE.
COMMUNICATIONS NETWORK. THE CONTRACTOR WILL NOT BE GRANTED AN EXTENSION
OCCURRING BEFORE FINAL ACCEPTANCE AT NO ADDITIONAL COST TO THE IOWA
22. CONTRACTOR SHALL REPLACE OR REPAIR, AS DIRECTED BY THE ENGINEER, ANY DAMAGE
OTDR TEST TO THE ENGINEER UPON COMPLETION.
WITHIN SEVENTY TWO (72) HOURS AFTER NOTIFICATION AND SUBMIT A COPY OF THE
ACCEPTANCE, CONTRACTOR SHALL PERFORM OTDR TESTING OF ALL FIBER STRANDS
21. IN THE EVENT IT IS SUSPECTED THAT CABLE DAMAGE HAS OCCURRED PRIOR TO FINAL
MARKINGS FOR THAT FIBER. COORDINATE FINAL MARKER LOCATIONS WITH ICN.
OWNED BY THE OTHER AGENCY (OR ENTITY), INSTALL TYPICAL IDENTIFIERS AND/OR
OF TRANSPORTATION/OTHER AGENCY (OR ENTITY) USE WHERE THE FIBER WILL BE
HANDHOLE TO BUILDING, ETC.) FOR FIBER INSTALLATIONS WITH JOINT DEPARTMENT
RUN ORIGINATED AND WHERE IT ENDS (HANDHOLE TO HANDHOLE, HANDHOLE TO CABINET,
AND SPLICE VAULT. TAGS SHALL CLEARLY IDENTIFY WHERE EACH INDIVIDUAL CABLE
AND DIRECTION OF THE CABLE AT EACH TERMINATION POINT AND IN EVERY HANDHOLE
20. CONTRACTOR SHALL PLACE TAGS ON ALL FIBER OPTIC CABLE IDENTIFYING THE OWNER
FIBER
- AT HANDHOLES (COORDINATE WITH ICN FOR FINAL LOCATIONS PRIOR TO PLACING ANY MARKERS).
LOCAL ROW ENTITY (PLACED AT EDGE OF ROW).
- APPROXIMATELY EVERY 1 / 4 MILE ALONG FIBER ROUTE OR MORE IF REQUIRED BY
- AT BEGINNING AND END OF BORES WHEN TRANSITIONING FROM DIRECT BURIED.
- AT INTERSECTIONS OR ROAD CROSSINGS (EACH SIDE).
- AT EVERY CHANGE OF DIRECTION OF FIBER CABLE ROUTE.
26. WARNING MARKERS FOR FIBER OPTIC CABLE SHOULD TYPICALLY BE PLACED:
BURIED FIBER CABLES.
25. CONTRACTOR SHALL INSTALL WARNING TAPE OVER ALL PLOWED CONDUIT AND DIRECT
19. NO OPEN HOLES, POTHOLES OR MOUNDS OF DIRT SHALL BE LEFT UNPROTECTED DURING
gehrhorn9:32:00 AM 7/10/2017 gehrhorn9:32:00 AM 7/10/2017
7/11/2017
11 x 17SCALE: SIZE:
GRIMES STATE OFFICE BUILDING
ICN C , COPY WITH PERMISSION
IOWA COMMUNICATIONS NETWORK
2014
DES MOINES, IOWA 50319
400 EAST 14TH STREET
THIS DRAWING IS PROVIDED FOR GENERAL
INFORMATION ONLY AND IS NOT TO BE USED
TO DETERMINE PRECISE ICN PLACEMENT.
CALL ONE CALL BEFORE EXCAVATION
(1-800-292-8989 OR 811)F:\2016\0501-1000\016-0760\40-Design\Microstation\016-0760_Grinnell College Connection\Sheets\General Notes_02.dgn
GRINNELL COLLEGE CONNECTION
GRINNELL, IA
Sheet 11 x 17
OSP LOG #79160205
6/22/2017
FINAL
PRELIM
2
1
UTILITY CONTACTS
72 HOUR ADVANCE NOTICE IS REQUIRED TO NOTIFY ALL UTILITY COMPANIES.
OF ALL UTILITIES, AND COORDINATE IF NEEDED, PRIOR TO COMMENCING WORK.
NOTE 1: THIS LIST IS NOT ALL-INCLUSIVE. CONTRACTOR IS RESPONSIBLE TO REQUEST LOCATES
OF THE INSTALLATION DEPENDING ON ROW AVAILABILITY.
APPROPRIATE OFFSET (APPROXIMATELY 2') OR CHANGE DEPTH
UTILITIES WOULD BE TO ADJUST THE RUNNING LINE BY AN
AUTHORITY HAVING JURISDICTION. THE PLAN FOR PARALLEL
RUNNING LINE REQUIRE PRE-APPROVAL BY THE ICN AND ROW
NOTE 2: EXISTING UTILITY CONFLICTS: ANY CHANGES TO THE PLANNED
C.03gehrhorn9:32:20 AM 7/10/2017 gehrhorn9:32:20 AM 7/10/2017
7/11/2017
11 x 17SCALE: SIZE:
GRIMES STATE OFFICE BUILDING
ICN C , COPY WITH PERMISSION
IOWA COMMUNICATIONS NETWORK
2014
DES MOINES, IOWA 50319
400 EAST 14TH STREET
THIS DRAWING IS PROVIDED FOR GENERAL
INFORMATION ONLY AND IS NOT TO BE USED
TO DETERMINE PRECISE ICN PLACEMENT.
CALL ONE CALL BEFORE EXCAVATION
(1-800-292-8989 OR 811)F:\2016\0501-1000\016-0760\40-Design\Microstation\016-0760_Grinnell College Connection\Sheets\General Notes_03.dgn
GRINNELL COLLEGE CONNECTION
GRINNELL, IA
Sheet 11 x 17
OSP LOG #79160205
6/22/2017
FINAL
PRELIM
2
1
gseib9:21:31 AM
F:\2016\0501-1000\016-0760\40-Design\Microstation\016-0760_Grinnell College Connection\Sheets\Grinnell College Connection_N.01.dgn
7/11/2017
SCALE: SIZE:
GRIMES STATE OFFICE BUILDING
ICN C , COPY WITH PERMISSION
IOWA COMMUNICATIONS NETWORK
2014
DES MOINES, IOWA 50319
400 EAST 14TH STREET
THIS DRAWING IS PROVIDED FOR GENERAL
INFORMATION ONLY AND IS NOT TO BE USED
TO DETERMINE PRECISE ICN PLACEMENT.
CALL ONE CALL BEFORE EXCAVATION
(1-800-292-8989 OR 811)11 x 17
1
Sheet
7/11/2017GRINNELL COLLEGE CONNECTION
GRINNELL, IA
OSP LOG #79160205
FINAL
PRELIM 6/22/2017
2
1
MA
TC
H LIN
E S
HE
ET
N.0
2
INSTALL UNDER SIDEWALK
L
5+71 C R
OA
D
SEC. 8
T-80N, R-16W,
POWESHIEK CO.
1"=50'N.01
MAINTENANCE BLDG
1333 Sunset Street
Grinnell High School GRINNELL HS FOT ROOM
ICN Sta. 0+00
SEE U.01 AND SCOPE OF WORK FOR DETAILS.
BOND THE END OF THE COIL TO BUILDING GROUND.LEAVE 30' COIL OF 12F/A AT RACK AS SHOWN
RACK-MOUNT FDP AS SHOWN.
DO NOT PASS THROUGH ANY EXISTING COILS.
ROUTE FIBER TO RACK AS PICTURED.
COIL 50 FEET OF ICN 12F/A ON STORAGE RING
(1) 12-INCH LEVITON STORAGE RING ON WALL
HANDHOLE HH 1-4E
ICN Sta. 5+16
828' from HH 1-4E to HH 2-1
(1E)
HANDHOLE HH 1-3E
ICN Sta. 2+23
HANDHOLE HH 1-2E
ICN Sta. 1+86
HANDHOLE HH 1-1E
ICN Sta. 0+73
113' from HH 1-1E to HH 1-2E
(1B)
37' from HH 1-2E to HH 1-3E
(1C)
Sunset St
293' from HH 1-3E to HH 1-4E
(1D)
ICN LINK 0605
73' from DATA ROOM to HH 1-1E
(1A)
100' COIL ICN 12F/A
EXISTING SCHOOL HANDHOLE
FOR ASSISTANCE
SEE SCHOOL FACILITIES DIRECTOR
37 FT NW OF HH 1-2E
LOOK IN DEPRESSION BY DRIVEWAY
NOTE HH IS BURIED APPROX. 21 INCHES.
10' COIL ICN 12F/A (PASS THROUGH)
EXISTING ICN HH
150' COIL ICN 12F/A
ENTER HH FROM THE BOTTOM
BEGIN BORE
EXISTING ICN HANDHOLE
(1) PULL ROPE
(1) ICN 12F/A
(1) ICN 2" HDPE BORED
(1) PULL ROPE
(1) ICN 12F/A
EXISTING ICN MULTICELL CONDUIT
(1) PULL ROPE
(1) ICN 12F/A
EXISTING SCHOOL (2) 3" CONDUITS
(1) PULL ROPE
(1) ICN 12F/A
EXISTING SCHOOL CONDUIT
(1) PULL ROPE
(1) ICN 12F/A
EXISTING SCHOOL CONDUIT
10-FOOT COIL 12F/A (PASS THROUGH)
EXISTING SCHOOL HANDHOLE
OO
FEET
50
gehrhorn9:33:25 AM
F:\2016\0501-1000\016-0760\40-Design\Microstation\016-0760_Grinnell College Connection\Sheets\Grinnell College Connection_N.02.dgn
7/10/2017
SCALE: SIZE:
GRIMES STATE OFFICE BUILDING
ICN C , COPY WITH PERMISSION
IOWA COMMUNICATIONS NETWORK
2014
DES MOINES, IOWA 50319
400 EAST 14TH STREET
THIS DRAWING IS PROVIDED FOR GENERAL
INFORMATION ONLY AND IS NOT TO BE USED
TO DETERMINE PRECISE ICN PLACEMENT.
CALL ONE CALL BEFORE EXCAVATION
(1-800-292-8989 OR 811)11 x 17
1
Sheet
7/11/2017GRINNELL COLLEGE CONNECTION
GRINNELL, IA
OSP LOG #79160205
FINAL
PRELIM 6/22/2017
2
1
MA
TC
H LI N
E S
HE
ET
N.0
1
MATCH LINE SHEET N.03
1E
INSTALL UNDER SIDEWALK
INSTALL UNDER SIDEWALK
L13+70 C ROAD
SEC. 8
T-80N, R-16W,
POWESHIEK CO.
1"=50'N.02
(1) ICN 2" HDPE (1) ICN 12F/A (1) PULL ROPE
HANDHOLE HH 2-1
ICN Sta. 13+44
Sunset St
8th A
ve
878' from HH 2-1 to HH 3-1
(2A)
150' COIL OF ICN 12 SM ARMORED FIBER
INSTALL ADJACENT TO UTILITY POLE
1 EA. INSTALL ICN HANDHOLE, 24" x 36" x 30"
(1) PULL ROPE
(1) ICN 12F/A
(1) ICN 2" HDPE BORED
OO
FEET
50
gehrhorn9:33:52 AM
F:\2016\0501-1000\016-0760\40-Design\Microstation\016-0760_Grinnell College Connection\Sheets\Grinnell College Connection_N.03.dgn
7/10/2017
SCALE: SIZE:
GRIMES STATE OFFICE BUILDING
ICN C , COPY WITH PERMISSION
IOWA COMMUNICATIONS NETWORK
2014
DES MOINES, IOWA 50319
400 EAST 14TH STREET
THIS DRAWING IS PROVIDED FOR GENERAL
INFORMATION ONLY AND IS NOT TO BE USED
TO DETERMINE PRECISE ICN PLACEMENT.
CALL ONE CALL BEFORE EXCAVATION
(1-800-292-8989 OR 811)11 x 17
1
Sheet
7/11/2017GRINNELL COLLEGE CONNECTION
GRINNELL, IA
OSP LOG #79160205
FINAL
PRELIM 6/22/2017
2
1
MA
TC
H LI N
E S
HE
ET
N.0
4
MA
TC
H LIN
E S
HE
ET
N.0
2
2A
INSTALL UNDER SIDEWALK
L17+83 C R
OA
D
L21+83 C R
OA
D
SEC. 8
T-80N, R-16W,
POWESHIEK CO.
1"=50'N.03
(1) ICN 2" HDPE (1) ICN 12F/A (1) PULL ROPE
8th Ave
Prince St
Prairie St
975' from HH 3-1 to HH 5-1
(3A)
HANDHOLE HH 3-1
ICN Sta. 22+22
150' COIL OF 12 SM ARMORED FIBER
1 EA. INSTALL ICN HANDHOLE, 24" x 36" x 30"
(1) PULL ROPE
(1) ICN 12F/A
(1) ICN 2" HDPE BORED
O
FEET
50
gehrhorn9:34:19 AM
F:\2016\0501-1000\016-0760\40-Design\Microstation\016-0760_Grinnell College Connection\Sheets\Grinnell College Connection_N.04.dgn
7/10/2017
SCALE: SIZE:
GRIMES STATE OFFICE BUILDING
ICN C , COPY WITH PERMISSION
IOWA COMMUNICATIONS NETWORK
2014
DES MOINES, IOWA 50319
400 EAST 14TH STREET
THIS DRAWING IS PROVIDED FOR GENERAL
INFORMATION ONLY AND IS NOT TO BE USED
TO DETERMINE PRECISE ICN PLACEMENT.
CALL ONE CALL BEFORE EXCAVATION
(1-800-292-8989 OR 811)11 x 17
1
Sheet
7/11/2017GRINNELL COLLEGE CONNECTION
GRINNELL, IA
OSP LOG #79160205
FINAL
PRELIM 6/22/2017
2
1
MA
TC
H LI N
E S
HE
ET
N.0
5
MA
TC
H LIN
E S
HE
ET
N.0
3
3A
INSTALL UNDER SIDEWALK
L25+82 C R
OA
D
SEC. 8
T-80N, R-16W,
POWESHIEK CO.
1"=50'N.04
(1) ICN 2" HDPE (1) ICN 12F/A (1) PULL ROPE
8th Ave
Reed St
O
FEET
50
gehrhorn9:34:46 AM
F:\2016\0501-1000\016-0760\40-Design\Microstation\016-0760_Grinnell College Connection\Sheets\Grinnell College Connection_N.05.dgn
7/10/2017
SCALE: SIZE:
GRIMES STATE OFFICE BUILDING
ICN C , COPY WITH PERMISSION
IOWA COMMUNICATIONS NETWORK
2014
DES MOINES, IOWA 50319
400 EAST 14TH STREET
THIS DRAWING IS PROVIDED FOR GENERAL
INFORMATION ONLY AND IS NOT TO BE USED
TO DETERMINE PRECISE ICN PLACEMENT.
CALL ONE CALL BEFORE EXCAVATION
(1-800-292-8989 OR 811)11 x 17
1
Sheet
7/11/2017GRINNELL COLLEGE CONNECTION
GRINNELL, IA
OSP LOG #79160205
FINAL
PRELIM 6/22/2017
2
1
MA
TC
H LI N
E S
HE
ET
N.0
6
MA
TC
H LIN
E S
HE
ET
N.0
4
3A
INSTALL UNDER SIDEWALK
LP
L31+76 C R
OA
D
L37+89 C R
OA
D
SEC. 8
T-80N, R-16W,
POWESHIEK CO.
1"=50'N.05
(1) ICN 2" HDPE (1) ICN 12F/A (1) PULL ROPE
HANDHOLE HH 5-1
ICN Sta. 31+97
8th Ave
Spencer St
Spring St
Ha
mlin St
1,012' from HH 5-1 to HH 6-1
(5A)
(1) PULL ROPE
(1) ICN 12F/A
(1) ICN 2" HDPE BORED
TYCO 450BS SPLICE CASE AND BONDING OF TRACER BY OTHERS. MID-SHEATH SPLICE TO ISOLATE CABLE ARMOR FOR LOCATING. GROUND ONE TERMINAL ON Tii WITH #8 BARE COPPER. TO HANDHOLE. COILS CAN BE TERMINATED BY OTHERS. INSTALL TWO (2) COILS OF TRACER WIRE, 75 FEET EACH, FROM Tii150' COIL OF 12 SM ARMORED FIBER
1 EA. GROUND ROD
SEE TYPICAL DETAIL ATTACHED
INSTALL ON UTILITY POLE
1 EA. Tii LOCATE TERMINAL
INSTALL ADJACENT TO UTILITY POLE
1 EA. INSTALL HANDHOLE, 24" x 36" x 30"
O
FEET
50
14+00
15+00
16+00
17+00
18+00
MP 22.15
14+00
15+00
16+00
17+00
18+00
MP 22.15
gehrhorn9:35:09 AM
F:\2016\0501-1000\016-0760\40-Design\Microstation\016-0760_Grinnell College Connection\Sheets\Grinnell College Connection_N.06.dgn
7/10/2017
SCALE: SIZE:
GRIMES STATE OFFICE BUILDING
ICN C , COPY WITH PERMISSION
IOWA COMMUNICATIONS NETWORK
2014
DES MOINES, IOWA 50319
400 EAST 14TH STREET
THIS DRAWING IS PROVIDED FOR GENERAL
INFORMATION ONLY AND IS NOT TO BE USED
TO DETERMINE PRECISE ICN PLACEMENT.
CALL ONE CALL BEFORE EXCAVATION
(1-800-292-8989 OR 811)11 x 17
1
Sheet
7/11/2017GRINNELL COLLEGE CONNECTION
GRINNELL, IA
OSP LOG #79160205
FINAL
PRELIM 6/22/2017
2
1
MA
TC
H LI N
E S
HE
ET
N.0
7
MA
TC
H LIN
E S
HE
ET
N.0
5
5A
INSTALL UNDER SIDEWALK
L41+83 C R
OA
D
BORE PIT, - Iowa DOT Sta. 15+56, 26' RT
SEC. 8, 9
T-80N, R-16W,
POWESHIEK CO.
1"=50'N.06
(1) ICN 2" HDPE (1) 12F/A (1) PULL ROPE
8th Ave
Hig
hway 1
46
1,265' from HH 6-1 to HH 8-1E
(6A)
HANDHOLE HH 6-1
IOWA DOT Sta. 15+56, 26' RT.
ICN Sta. 42+09
150' COIL OF ICN 12 SM ARMORED FIBER
1 EA. INSTALL ICN HANDHOLE, 24" x 36" x 30"
(1) PULL ROPE
(1) ICN 12F/A
(1) ICN 2" HDPE BORED
8
8
9
9
O
FEET
50
gehrhorn9:35:29 AM
F:\2016\0501-1000\016-0760\40-Design\Microstation\016-0760_Grinnell College Connection\Sheets\Grinnell College Connection_N.07.dgn
7/10/2017
SCALE: SIZE:
GRIMES STATE OFFICE BUILDING
ICN C , COPY WITH PERMISSION
IOWA COMMUNICATIONS NETWORK
2014
DES MOINES, IOWA 50319
400 EAST 14TH STREET
THIS DRAWING IS PROVIDED FOR GENERAL
INFORMATION ONLY AND IS NOT TO BE USED
TO DETERMINE PRECISE ICN PLACEMENT.
CALL ONE CALL BEFORE EXCAVATION
(1-800-292-8989 OR 811)11 x 17
1
Sheet
7/11/2017GRINNELL COLLEGE CONNECTION
GRINNELL, IA
OSP LOG #79160205
FINAL
PRELIM 6/22/2017
2
1
MA
TC
H LI N
E S
HE
ET
N.0
8
MA
TC
H LIN
E S
HE
ET
N.0
6
6A
INSTALL UNDER SIDEWALK
46+19 C R
OA
D
50+65 C R
OA
D
SEC. 9
T-80N, R-16W,
POWESHIEK CO.
1"=50'
LL
N.07
(1) ICN 2" HDPE (1) ICN 12F/A (1) PULL ROPE
8th Ave
Main St Bro
ad St O
FEET
50
gehrhorn9:35:57 AM
F:\2016\0501-1000\016-0760\40-Design\Microstation\016-0760_Grinnell College Connection\Sheets\Grinnell College Connection_N.08.dgn
7/10/2017
SCALE: SIZE:
GRIMES STATE OFFICE BUILDING
ICN C , COPY WITH PERMISSION
IOWA COMMUNICATIONS NETWORK
2014
DES MOINES, IOWA 50319
400 EAST 14TH STREET
THIS DRAWING IS PROVIDED FOR GENERAL
INFORMATION ONLY AND IS NOT TO BE USED
TO DETERMINE PRECISE ICN PLACEMENT.
CALL ONE CALL BEFORE EXCAVATION
(1-800-292-8989 OR 811)11 x 17
1
Sheet
7/11/2017GRINNELL COLLEGE CONNECTION
GRINNELL, IA
OSP LOG #79160205
FINAL
PRELIM 6/22/2017
2
1
MA
TC
H LIN
E S
HE
ET
N.0
7
MATCH LINE SHEET N.09
6A
L55+04 C ROAD
SEC. 9
T-80N, R-16W,
POWESHIEK CO.
1"=50'N.08
(1) ICN 2" HDPE (1) ICN 12F/A (1) PULL ROPE
163' from HH 8-1E to HH 8-2E
(8A)
345' from HH 8-2E to HH 9-1E
(8B)
HANDHOLE HH 8-1E
ICN Sta. 54+74
HANDHOLE HH 8-2E
ICN Sta. 56+37
8th Ave
Park St
150' COIL ICN 12F/A
ENTER HANDHOLE FROM BOTTOM
EXISTING COLLEGE HANDHOLE
END OF BORE
(1) PULL ROPE
(1) ICN 12F/A
(2) EXISTING COLLEGE 4" CONDUITS
10 FEET OF SLACK ICN 12F/A (PASS THROUGH)
EXISTING COLLEGE HANDHOLE
(1) PULL ROPE
(1) ICN 12F/A
(2) EXISTING COLLEGE 4" CONDUITS
O
FEET
50
gehrhorn9:36:17 AM
F:\2016\0501-1000\016-0760\40-Design\Microstation\016-0760_Grinnell College Connection\Sheets\Grinnell College Connection_N.09.dgn
7/10/2017
SCALE: SIZE:
GRIMES STATE OFFICE BUILDING
ICN C , COPY WITH PERMISSION
IOWA COMMUNICATIONS NETWORK
2014
DES MOINES, IOWA 50319
400 EAST 14TH STREET
THIS DRAWING IS PROVIDED FOR GENERAL
INFORMATION ONLY AND IS NOT TO BE USED
TO DETERMINE PRECISE ICN PLACEMENT.
CALL ONE CALL BEFORE EXCAVATION
(1-800-292-8989 OR 811)11 x 17
1
Sheet
7/11/2017GRINNELL COLLEGE CONNECTION
GRINNELL, IA
OSP LOG #79160205
FINAL
PRELIM 6/22/2017
2
1
MA
TC
H LI N
E S
HE
ET
N.0
8
8B
1103 Park Street
John Chrystal Center
L60+33 C R
OA
D
SEC. 9
T-80N, R-16W,
POWESHIEK CO.
1"=50'N.09
(2) EX. COLLEGE 4" CONDUITS NEW (1) ICN 12F/A (1) PULL ROPE
COORDINATE WITH ICN AND GRINNELL COLLEGE.
FOR BUILDING ENTRANCE DETAILS.
SEE SCOPE OF WORK AND SHEETS U.02-U.03
TO THE GROUND FURNISHED BY THE COLLEGE.
BOND THE ARMOR AT THE END OF THE 12 F/A
LEAVE 25' TAIL FOR SPLICING BY OTHERS.
LEAVE 50' COIL OF 6F/D AT ON RING.
LEAVE 25' TAIL FOR SPLICING BY OTHERS.
LEAVE 25' COIL OF 12F/A ON RING
INSTALL 24-INCH LEVITON STORAGE RING.
END OF COLLEGE BUILDING ENTRY CONDUIT
ICN Sta. 64+05 CHRYSTAL CENTER BASEMENT
HANDHOLE HH 9-1E
ICN Sta. 59+82
HANDHOLE HH 9-2E
ICN Sta. 61+35216' from HH 9-2E to 9-3E
(9B)HANDHOLE HH 9-3E
ICN Sta. 63+51
54' from HH 9-3E to BUILDING ENTRANCE
(9C)
Park St
7th A
ve
153' from HH 9-1E to 9-2E
(9A)
150' COIL OF ICN 12F/A
EXISTING COLLEGE HANDHOLE
(1) PULL ROPE
(1) ICN 12F/A
(2) EXISTING COLLEGE 4" CONDUITS
(1) PULL ROPE
(1) ICN 12F/A
(2) EXISTING COLLEGE 4" CONDUITS
10 FEET OF SLACK 12F/A (PASS THROUGH)
EXISTING COLLEGE HANDHOLE150' COIL OF ICN 12F/A
EXISTING COLLEGE HANDHOLE
SEE DETAIL ON SHEETS U.02-U.03
(1) PULL ROPE
(1) ICN 12F/A
(1) EXISTING 4" COLLEGE CONDUIT
(1) EXISTING 2" COLLEGE CONDUIT
150' CABLE TRAY TO DATA ROOM
STORAGE RING AND SPLICE
Sta. 64+15
SEE SHEETS U.02-U.03
BASEMENT DATA ROOM
Sta. 65+65
O
FEET
50
gehrhorn9:36:33 AM
F:\2016\0501-1000\016-0760\40-Design\Microstation\016-0760_Grinnell College Connection\Sheets\Grinnell College Connection_U.01.dgn
7/10/2017
SCALE: SIZE:
GRIMES STATE OFFICE BUILDING
ICN C , COPY WITH PERMISSION
IOWA COMMUNICATIONS NETWORK
2014
DES MOINES, IOWA 50319
400 EAST 14TH STREET
THIS DRAWING IS PROVIDED FOR GENERAL
INFORMATION ONLY AND IS NOT TO BE USED
TO DETERMINE PRECISE ICN PLACEMENT.
CALL ONE CALL BEFORE EXCAVATION
(1-800-292-8989 OR 811)11 x 17
1
Sheet
7/11/2017GRINNELL COLLEGE CONNECTION
GRINNELL, IA
OSP LOG #79160205
FINAL
PRELIM 6/22/2017
2
1
GRINNELL HIGH SCHOOL BUILDING ENTRANCE DETAILS
U.01
1.3
U.01
1.1
(Northeast Building Face)
Grinnell High School Exterior
U.01
U.01
1.2 Grinnell High School FOT Room
Grinnell High School FOT Room
HH 1-1E INTO FOT ROOM.
INSTALL IN EXISTING 4" CONDUIT FROM
(1) PULL ROPE
(1) ICN 12F/A
GRINNELL HS FOT ROOM IN MAINTENANCE BUILDING
gehrhorn9:36:59 AM
F:\2016\0501-1000\016-0760\40-Design\Microstation\016-0760_Grinnell College Connection\Sheets\Grinnell College Connection_U.02.dgn
7/10/2017
SCALE: SIZE:
GRIMES STATE OFFICE BUILDING
ICN C , COPY WITH PERMISSION
IOWA COMMUNICATIONS NETWORK
2014
DES MOINES, IOWA 50319
400 EAST 14TH STREET
THIS DRAWING IS PROVIDED FOR GENERAL
INFORMATION ONLY AND IS NOT TO BE USED
TO DETERMINE PRECISE ICN PLACEMENT.
CALL ONE CALL BEFORE EXCAVATION
(1-800-292-8989 OR 811)11 x 17
1
Sheet
7/11/2017GRINNELL COLLEGE CONNECTION
GRINNELL, IA
OSP LOG #79160205
FINAL
PRELIM 6/22/2017
2
1
JOHN CHRYSTAL CENTER BUILDING ENTRANCE DETAILS
U.02
2.1
U.02
2.2
U.02
2.3HH 9-3 Interior
U.02
Chrystal Center Fiber Path
Building Entrance and Splice
Chrystal Center Basement
COLLEGE 4" CONDUIT
(1) ICN 12F/A IN EXISTING
gehrhorn9:37:18 AM
F:\2016\0501-1000\016-0760\40-Design\Microstation\016-0760_Grinnell College Connection\Sheets\Grinnell College Connection_U.03.dgn
7/10/2017
SCALE: SIZE:
GRIMES STATE OFFICE BUILDING
ICN C , COPY WITH PERMISSION
IOWA COMMUNICATIONS NETWORK
2014
DES MOINES, IOWA 50319
400 EAST 14TH STREET
THIS DRAWING IS PROVIDED FOR GENERAL
INFORMATION ONLY AND IS NOT TO BE USED
TO DETERMINE PRECISE ICN PLACEMENT.
CALL ONE CALL BEFORE EXCAVATION
(1-800-292-8989 OR 811)11 x 17
1
Sheet
7/11/2017GRINNELL COLLEGE CONNECTION
GRINNELL, IA
OSP LOG #79160205
FINAL
PRELIM 6/22/2017
2
1
JOHN CHRYSTAL CENTER BUILDING ENTRANCE DETAILS
U.03
3.1
U.03
3.2
U.03
Chrystal Center Basement Chrystal Center Basement
COLLEGE ON LOCATION OF FDP.
COORDINATE WITH ICN AND
SPLICE CASE TO DATA ROOM.
APPROXIMATELY 145' FROM
(1) ICN 6F/D PLENUM RATED FIBER
COIL 25 FEET BEHIND RACK FOR TERMINATION
COIL 50' AT STORAGE RING
12" LEVITON STORAGE RING
Sta. 65+65
30"
37 5/8"
26"37 5/8"30"
35 5/8"24"3"
24" X 36" X 30" NEW BASIS HAND HOLE
HANDHOLE PLACEMENT TYPICAL
12"
6" min.
37 5/8"
26"
5'MIN.
RIGHT-OF-W
AY
4' TYP.
6" ±
5'±
6" ±
IOWA COMMUNICATIONS NETWORK