Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.
-
Upload
bryan-banks -
Category
Documents
-
view
228 -
download
10
Transcript of Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.
![Page 1: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/1.jpg)
Legacy-GW Features
Rev1.4 24 Jan., 2013
![Page 2: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/2.jpg)
2
Over view
![Page 3: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/3.jpg)
3
Over view
1.Use NCP/TDE ( TDA ) as a legacy GW by stacking connection
with NS1000.
2.NCP/TDE(TDA) connect with NS by stacking card working
as part of One-look network.
![Page 4: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/4.jpg)
4
Over view
Introduce new card ; STACK-M (for NS), STACK-S (1 for NCP/ 1 for TDE)
NS1000 as stacking Master Unit
NCP500NCP1000
STACK-S card
STACK-M cardSite #1
Site #2
Site #3
Site #4 : :
LAN
Stacking Slave
Stacking Slave
Slave Units
Stacking Slave
Stacking Slave
Proprietary cable for stacking connectionThe length of the cable : 2M(Dedicate cable for these Stacking card)
Master forOne-look
![Page 5: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/5.jpg)
5
Symbol Model Name Description Remark
STACK-M KX-NS0130 Stacking Master Card
- Interface card for Legacy-GW
- Proprietary Interface x 2 ports
Over view
Symbol Model Name Description Remark
STACK-S (NCP) KX-NS0131
Stacking EXP Card for NCP
Legacy-GW Control Unit for NCP
with Stacking Cable
STACK-S(TDE/TDA) KX-NS0132
Stacking EXP Card for TDE/TDA
Legacy-GW Control Unit for TDE/TDA
with Stacking Cable
New card
![Page 6: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/6.jpg)
6
Condition
![Page 7: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/7.jpg)
7
Condition 1
STACK-S card
STACK-M card
Stacking Slave #1
Stacking Slave #2
1.MPR of NCP has to be removed to install Stack-S card. This means Virtual card on NCP is not supported. All of IP terminal has to connect to NS1000.
2.Type of GW has to be same for each NS1000.
Category1: NCP500 /NCP1000
Category2: TDE100/200, TDA100/200
Category3: TDE600/620, TDA600/620
3.Max 2 GW for each NS. Max 8 for entire One-look network. 4.TDA15/30/50/100D is not supported.
5. AK is not required to use Legacy GW.
*If the type of cabinet is mixed then
2nd one will not be worked.
![Page 8: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/8.jpg)
8
Condition 2
TDE600
TDE620
NS1000
In case of TDE600 each cabinet count as 1 GW and connection to NS has to be done by Stack-S card.
Bus card in TDE600 and TDE620 has to be removed.
TDE620
TDE620
NS1000
TDE600
TDE600
NS1000
OR OR
![Page 9: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/9.jpg)
9
Symbol Model Description
RMT TDA0196 Analogue Modem for Remote Maintenance
MEC TDA0105/TDE0105
Memory Expansion Card
DSP4 NCP1104 VoIP channel card 4ch
DSP16 TDE0110 VoIP channel card 16ch
DSP64 TDE0111 VoIP channel card 64ch
CTI-LINK TDA0410 CTI Link Card
IP-EXT16 TDA0470 16-Channnel VoIP Extension Card
IP-GW4E TDA0484 4-Channnel VoIP Gateway Card
IP-GW16 TDA0490 16-Channnel VoIP Gateway Card
IP GW4 TDA0480 4 Channel VoIP Gateway Card
MSG4 TDA0191 4-Channel Message Card
ESVM2 TDA0192 2-Channel Simplified Voice Message Card
ESVM4 TDA0194 4-Channel Simplified Voice Message Card
CLCOT8 TDA1180 8-Port Analogue Trunk Base Card w/ Caller ID
CLCOT8E TDA1186 8-Port Analogue Trunk Daughter Card w/ Caller ID
MCSLC24 TDA1178 24-Port Single Line Telephone Card
MCSLC16 TDA1176 16-Port Single Line Telephone Card
Which Optional card can not be used at Legacy GW?
Condition 3
Basically
Optional card
1)on TDE/NCP MPR
2)Support by V5 or later
3) IP-GW, IP-EXT
4) MSG
are not supported.
![Page 10: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/10.jpg)
10
Condition 4
How many CO can be installed in each Legacy GW?Stand-alone Stacking system
One LookNetworking
1NCP5001NCP1000
1TDE/TDA1001TDE/TDA 2001TDE/TDA 600
2NCP5002NCP1000
2TDE/TDA 1002TDE/TDA 2002TDE/TDA 600
Trunk(ch) 256 256 600IP 256 256 256
SIP 256 256 256H.323 48 48 96
Legacy 30 0 64/64/120/128/160 128/128/240/256/256 600
LCOT 2 0 12/16/96/128/160 24/32/192/256/256 600
BRI 8 0 12/16/96/128/160 24/32/192/256/256 600
PRI23 23 0 46/46/92/92/115 92/92/184/184/230 600
PRI30 30 0 60/60/120/120/150 120/120/240/240/256 600
T1 0 0 48/48/96/96/120 96/96/192/192/240 600
E1 0 0 60/60/120/120/150 120/120/240/240/256 600
![Page 11: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/11.jpg)
11
Condition 5
How many EXT can be installed in each Legacy GW?Stand-alone
Stacking systemOne LookNetworkin
g
1NCP1TDE/TDA1001TDE/TDA 2001TDE/TDA 600
2NCP2TDE/TDA 1002TDE/TDA 2002TDE/TDA 600
Extension(ch) 640 640 1000IP 640 640 1000
IP-PT 256 256 1000SIP 640 640 1000
SIP Phone 640 640 1000KX-UT series 640 640 1000
S-PS(SIP based DECT) 255 255 255
Legacy *1 2 0 44/160/256/304 88/320/512/608 1000
SLT 2 0 36/96/128/240 72/192/256/480 1000
DPT 0 0 40/128/256/256 80/256/512/512 1000
![Page 12: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/12.jpg)
12
Stand-aloneStacking system
One LookNetworking
1NCP1TDE/TDA1001TDE/TDA 2001TDE/TDA 600
2NCP2TDE/TDA 1002TDE/TDA 2002TDE/TDA 600
CS (pcs) 64 64 128
DPT-CS (2ch) 0 0 11/32/32/32 22/64/64/64 128
DPT-CS (8ch) 0 0 5/16/16/16 10/32/32/32 64
IP-CS 64 *2 64 *2 128 *2
SIP-CS 64 *3 64 *3 128 *3
PS(DECT)(pcs) 512 512 512
VM
Built-in UM (ch) 24 24 24ch x16
TVA/TVM (ch) 0 0 48 (24ch x2) 24ch x8
Condition 6
*2 The maximum number of Air Sync Groups is 16. An Air Sync Group can contain up to 16 IP-CSs.
*3 The maximum number of Air Sync Groups is 8. An Air Sync Group can contain up to 32 SIP-CSs.
How many other devices can be installed in each Legacy GW?
![Page 13: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/13.jpg)
13
• AK on NCP/TDE can’t be transferred to NS MPR.
Condition 7
• In case of TDA100/200 and TDE100/200
OPB3 card with ECHO16 must be installed in only SLOT1.- Other than OPB3 card allows to install in any SLOT.- OPB3 card with sub-card except for ECHO16 allows installing in any SLOT.
• HGT100, NT400 can’t be connected to NS MPR.
![Page 14: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/14.jpg)
14
How to work?
![Page 15: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/15.jpg)
15
How to work?
Installation
• Both Stack-M and Stack-S card is non hot swappable.• Each cabinet can be power on without any order.• Initial Legacy-GW installation, all card will be initialized.• The optional service cards is hot swappable.
• TVM can be installed as VM system for entire One-look.• CS can be installed at both NS(NCP0158) and Legacy-GW (TDA0141/142/155/156/158). PS can Hand over between these CS to CS(NCP0158, TDA0141/142/155/156/158).
![Page 16: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/16.jpg)
16
How to work?
Wireless•Hand over between NS to Legacy GW and Legacy GW to Legacy GW is available.
CS CS(TDA0141/142/155/156/158)
CS CS
IP-CS IP-CS(NCP0158)LAN
PS
•If Legacy CS and IPCS are mixed then all CS must be assign under Air sync group 1.
![Page 17: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/17.jpg)
17
How to work?
Start up
LED Status
“Stack-M” LED Green On : Normal working condition Off: Error( Not Working)
“Stack-S” LED Green On : INS Red On : Fault Red Flash: OUS
Legacy GW“RUN” LED Green Off :Power off On : Running as GW Slow Flash: While start up
“ALARM” LED Red Off : No present error On : Present Error
![Page 18: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/18.jpg)
18
How to work?
Maintenance
All below service for Legacy-GW is supported through NS1000 cabinet.
• Programming• Firmware update• Error log, Syslog• SNMP information• SMDR
![Page 19: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/19.jpg)
19
Programming
![Page 20: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/20.jpg)
20
Programming at NS1000
Programming
Button to switch Physical-Virtual-LegacyGW1-LegacyGW2
Each Optional Card can be selected and installed.
Stack S connect to “1” on
Stack M consider as “GW1”
![Page 21: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/21.jpg)
21
Programming at NS1000
Programming
LPR Software name same as existing models
LPR Software for STACK-S card “PSTKS” is new!
LPR Software :Software can be download through NS1000
![Page 22: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/22.jpg)
22
Programming at NS1000
Programming
Programming items related to Legacy GW support.
Related to VM. Related to DSS.
Port Property
![Page 23: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/23.jpg)
23
Appendix
![Page 24: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/24.jpg)
24
Appendix
Supported optional card
![Page 25: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/25.jpg)
25
Appendix
Supported optional card
![Page 26: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/26.jpg)
26
Appendix
Supported optional card
![Page 27: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/27.jpg)
27
END
![Page 28: Legacy-GW Features Rev1.4 24 Jan., 2013. 2 Over view.](https://reader036.fdocuments.in/reader036/viewer/2022062314/56649e4c5503460f94b412be/html5/thumbnails/28.jpg)
28
20120827-01 LegacyGW_Rev1_27Aug2012Mar.ppt
- 1st release
20120905-02 LegacyGW_Rev1_1_5Sep2012Mar.ppt
- Edit slide #11 revise number of legacy EXT and DPT.
- Add slide #12
20121031-03 LegacyGW_Rev1_2_31Oct2012Mar.ppt
- Add comment for slide #7 “No AK required”
- Add additional sample for slide #8
- Add comment for slide #9 “Basic idea”
- Add comment for #13 about HGT100 and NT400
- Add remark for #16
20121108-04 LegacyGW_Rev1_3_8Nov2012Mar.ppt
- correct slide #8 600-620 twice to 600-620 and 620-620
20130124-05 LegacyGW_Rev1_4_24Jan2013Mar.ppt
- correct slide #10 BRI and LCOT capacity for NCP500 as Legacy GW
Modification