Transcript of Landslide 01 Installation

  • 5/20/2018 Landslide 01 Installation

    1/14PROPRIETARY AND CONFIDENTIALMarch 2011

    Rev 1

    Installing the Software

  • 5/20/2018 Landslide 01 Installation

    2/142 PROPRIETARY AND CONFIDENTIAL

    Accessing the Equipment

    BRAND NEW SYSTEM: Connect to LS via Monitor and Keyboard. For 7100s: Remove the face plate

    to find the USB (mouse connector) and monitor connection.

    Upon start-up a new unit should prompt you for IP address information. If itdoes not type in ipcfg. This will start the script to IP the unit.

    Do this for both the TAS Manager and the Test Servers. These are all Dellservers the TAS manage will have no NIC cards.

  • 5/20/2018 Landslide 01 Installation

    3/143 PROPRIETARY AND CONFIDENTIAL

    Install the Landslide Setup FilesFactory Configuration System Installation

    Step Action1. Login to the system with the username root. The password for the root user is spirent.

    2. Insert the Landslide Software DVD into the DVDROM drive.

    3. Create a temporary mount point for the DVDROM drive

    ##> mkdir /dvdrom

    4. Mount the DVDROM drive to the newly created directory.

    ##> mount t auto /dev/sr0 /dvdrom

    5. Create a temporary install directory.##> mkdir /root/tmpinstall

    6. Switch to the temporary install directory.##> cd /root/tmpinstall

    7. Copy the Landslide installation file from the DVD to the temporary install directory.

    ##> cp /dvdrom/ .

    Note: Make sure to include the period at the end of the command.

    8. Extract the install file into the install directory.

    ##> tar zxvf Tip: Once you type tar zxvf you should be able to press the Tab key and have the Landslide install filename automatically

    complete.

    9. Unmount the DVDROM drive.

    ##> umount /dev/sr0

    10. Delete the temporary mount directory.

    ##> rmdir /dvdrom

    11. Remove DVD from DVDROM drive.

    Proceed to section 4.2 to configure as a TAS.

  • 5/20/2018 Landslide 01 Installation

    4/144 PROPRIETARY AND CONFIDENTIAL

    Install the Landslide Setup FilesLandslide TAS Configuration Procedure

    Step Action

    1. Run the install script

    ##> ./u64Install.sh tas

    The Landslide install will take a few minutes, as users, Java, MySql, Apache, TAS, TS,

    Test Suite and other items are installed and/or configured.

    Expect to see the following near the end of the output

    ------------------------------------------------

    Summary: A TAS is installed and enabled

    ------------------------------------------------

    NOTE: This procedure may result in some mv errors and java exception errors.

    These errors can be ignored, trust the Summary line for results.

    2. Remove all of the temporary files

    ##> cd ..

    ##> rm fr tmpinstall

    3. Reboot

    ##> reboot

    4. Login to the system with the username cfguser. The password for the root user is

    cfguser.

    5. Run ipcfg and follow prompts to configure the TAS Manager specific parameters.

    ##> ipcfg

  • 5/20/2018 Landslide 01 Installation

    5/145 PROPRIETARY AND CONFIDENTIAL

    Install the Landslide Setup FilesLandslide TS Configuration Procedure

    Step Action

    1. Run the install script

    ##> ./u64Install.sh ts

    The Landslide install will take a few minutes, as users, Java, MySql, Apache, TAS, TS, Test Suite

    and other items are installed and/or configured.

    Expect to see the following near the end of the output

    ------------------------------------------------

    Summary: A TS is installed and enabled

    ------------------------------------------------

    NOTE: This procedure may result in some mv errors and java exception errors. These errors can

    be ignored, trust the Summary line for results.

    2. Remove all of the temporary files

    ##> cd ..

    ##> rm fr tmpinstall

    3. If you are installing Landslide software on a system with ATM cards, you will need to install the

    atm configuration files.##> cd /home/spcoast/bin

    ##> ./atmcfg

    Note: The atmcfg command takes several minutes to complete.

    4. Reboot

    ##> reboot

    5. Login to the system with the username cfguser. The password for the root user is cfguser.

    6. Run ipcfg and setup the Test Server specific parameters.

    ##> ipcfg

  • 5/20/2018 Landslide 01 Installation

    6/146 PROPRIETARY AND CONFIDENTIAL

    Configuration Information Required

    TAS: IP Address [192.168.0.100]:

    Network Mask [255.255.255.0]:

    Auto Negotiate? (yes/no) [yes]:

    IP Gateway [192.168.0.254]:

    Host Name [Coast49]:

    NTP Server IP [192.168.0.100]:

    TS: IP Address [192.168.0.100]:

    Network Mask [255.255.255.0]: Auto Negotiate? (yes/no) [yes]:

    IP Gateway [192.168.0.254]:

    Host Name [Coast49]:

    TAS IP Address

    NTP Server IP [192.168.0.100]:

  • 5/20/2018 Landslide 01 Installation

    7/147 PROPRIETARY AND CONFIDENTIAL

    Browser Access

    TAS and the TS Servers are now accessible You can login to the GUI by typing in the TAS manager address

    into a web browser and lauch the Java GUI client:

    Login defaults:

    User = smsPassword = a1b2c3d4

  • 5/20/2018 Landslide 01 Installation

    8/14

    8 PROPRIETARY AND CONFIDENTIAL

    Linking TAS and TS

    Adding TS to TAS manager: Go to TS and add the IP addresses ofthe new Test Servers

  • 5/20/2018 Landslide 01 Installation

    9/14

    9 PROPRIETARY AND CONFIDENTIAL

    Adding IP Addresses to a Test Server

    Click on Configure to configure the NIC ports for the new TestServer.

    Password = cfguser

  • 5/20/2018 Landslide 01 Installation

    10/14

    10 PROPRIETARY AND CONFIDENTIAL

    Configure IP addresses on TS

    IP = Ip Networkaddress

    Mask= Network Mask

    Pool IP = First IPaddress within thisNetwork that isavailable to use on thisTest Server

    # of IPs = # of IPs

    within that networkthat you want to makeavailable to this TestServer

  • 5/20/2018 Landslide 01 Installation

    11/14

    11 PROPRIETARY AND CONFIDENTIAL11

    TAS System Upgrade

    Access TAS Manager

    The TAS Manager upgrade processtakes you through several steps:

    Stopping the TAS

    Backing up the system database(optional but highly recommended)

    Uploading and installing the newsoftware

    Restarting the TAS Manager

    Installing License

    Starting the TAS(or rebooting the platform)

  • 5/20/2018 Landslide 01 Installation

    12/14

    12 PROPRIETARY AND CONFIDENTIAL

    TS System Upgrade

    The TS upgrade file has .ste extension Click on Upgrade in the TS Administration Window.

    Select the .tsu file and click Upgrade

    Password = cfguser

  • 5/20/2018 Landslide 01 Installation

    13/14

    13 PROPRIETARY AND CONFIDENTIAL Spirent Landslide13

    Install New License License

    Access TAS Manager

    Stop TAS

    Customer Service will provide alicense file *.sql. Save it to your PCand browse to it when prompted

    Choose .sql file and click install Start TAS

  • 5/20/2018 Landslide 01 Installation

    14/14

    14 PROPRIETARY AND CONFIDENTIAL

    Quizz

    1. What items do you need to install the software in eitherTAS or TS?

    2. Which is the naming convention used by default for themanagement port?

    3. What is the Pool IP value?4. How do you link TAS and TS?