Kuhn Ke Solenoid

31
Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogs or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have been combined to provide technical information about the specific product(s) you have selected. Hard copy product catalogs, and CDROMs have been published describing Kuhnke Pneumatics, Solenoids, Relays and Electronics; some divided into different books. A list of current publications is available on this web site or from our sales offices. Some may be available for download, but as substantially larger files. Contact Details Kuhnke sales and service in North America Ellis/Kuhnke Controls 26 West Highland Avenue Atlantic Highlands New Jersey 07716 USA T: 800-221-0714 T: 732-291-3334 F: 732-291-8154 Email: [email protected] Important Note The information shown in these documents is for guidance only. No liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper application of the parts, assemblies or equipment described.

description

kuhnke solenoid specification

Transcript of Kuhn Ke Solenoid

Page 1: Kuhn Ke Solenoid

Kuhnke Technical Data

The following page(s) are extracted from multi-page Kuhnke product catalogs or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have been combined to provide technical information about the specific product(s) you have selected. Hard copy product catalogs, and CDROMs have been published describing Kuhnke Pneumatics, Solenoids, Relays and Electronics; some divided into different books. A list of current publications is available on this web site or from our sales offices. Some may be available for download, but as substantially larger files.

Contact Details

Kuhnke sales and service in North America Ellis/Kuhnke Controls 26 West Highland Avenue Atlantic Highlands New Jersey 07716 USA T: 800-221-0714 T: 732-291-3334 F: 732-291-8154 Email: [email protected]

Important Note The information shown in these documents is for guidance only. No liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper application of the parts, assemblies or equipment described.

Page 2: Kuhn Ke Solenoid

Hochleistungs-Hubmagnete RM, URM

Heavy Duty SolenoidsSeries RM, URM

Page 3: Kuhn Ke Solenoid

Typ RM einfachwirkendTyp URM umkehrwirkend

Die Typen RM und URM sind Hoch-leistungshubmagnete in geschlossenerBauweise. Diese Ausführungen sind be-vorzugt dort einzusetzen, wo höchsteLebensdauer gefordert wird. Durch einebeidseitige wartungsfreie Ankerlagerungwird diese Forderung erfüllt. Sie könnenin beliebiger Einbaulage montiert wer-den.

Die Spulenspannung wird in der Regel inGleichspannung ausgeführt (Wechsel-spannung auf Anfrage).

Neben den Standardtypen steht eineVielzahl von Sonderhubmagneten zurVerfügung (siehe Beispiele Seite 37-39).

Hochleistungs-Hubmagnete Geschlossene BauweiseTechnische Beschreibung/Vorzugstypen

Heavy Duty Linear SolenoidsFully Encapsulated Design

Technical description/Preferred types

104 Main catalogueMagnet Hauptkatalog

Series RM single acting,series URM two directional

Series RM and URM heavy duty solenoidsare fully enclosed. These specificationsare designed for maximum durability, thisbeing ensured by service-free armature bearing on both sides. These solenoidscan be mounted at any angle.

The coil voltage is usually designed forDC (AC on request).

Apart from the standard models we offeryou a multitude of custom-made linearsolenoids (see examples on pages 37-39).

RM070W-HROO-F

24VDC 100% ED

RM070W-HRRO-F

24VDC 100%

ED

RM070W-OBOO-F

24VDC 100% ED

RM070W-OROR-F

24VDC 100% ED

Page 4: Kuhn Ke Solenoid

Die obenstehenden Hochleistungs-Hub-magnete Typ RM werden als Vorzugs-typen lagermäßig geführt, damit Sie ei-nen schnellen und preisgünstigen Zugrifffür Ihre Versuche haben.

Die Vorzugstypen sind in kleinen Stück-zahlen (Zwischenverkauf vorbehalten)innerhalb einer Woche lieferbar.Sie sind ausgelegt für 24 V DC und 100 % ED.

Bei Verwendung einer verstellbarenSpannungsquelle kann der Magnet überdie Nennspannung hinaus betrieben wer-den, um die für die Betätigung erforderli-che Kraft zu erreichen.

Beachten Sie hierbei bitte, daß bei län-gerem Betrieb an erhöhter Betriebsspan-nung diese Magnete überhitzt werden,wenn nicht ausreichende Pausen bei ei-ner max. Spieldauer (Einschaltzeit + Aus-schaltzeit) von 5 Minuten eingehaltenwerden. Zu Ihrer Information hier der ma-thematische Zusammenhang:

U = Betriebsspannung (Anwender)UN = Nennspannung – bzw. Standard-

spannung 24 V DCED = relative Einschaltdauer (%)

Zur Ermittlung der für Ihren Anwendungs-fall erforderlichen Kraft ist der Spulen-strom zu messen. Die genaue Festlegungder Spule erfolgt in unserer Entwicklungs-abteilung: Geben Sie uns bitte hierzuden Magnetspulenstrom an, unter Berück-sichtigung der geforderten max. Ein-schaltdauer.

Hochleistungs-Hubmagnete Geschlossene BauweiseTechnische Beschreibung/Vorzugstypen

Heavy Duty Linear SolenoidsFully Encapsulated Design

Technical description/Preferred types

105 Main catalogueMagnet Hauptkatalog

The heavy duty solenoids listed in thetable are preferred types and are alwaysin stock, enabling you to have themdelivered quickly and at a competitiveprice for your tests.

The preferred types can be deliveredwithin a week (in small numbers) condi-tional to no resale. They are designed tooperate at 24 V DC and 100 % ED.

If an adjustable voltage source is used,the solenoid can be operated at a highervoltage than that given in the rating, inorder to obtain the required power.

However, these solenoids are subject tooverheating during long term use with in-creased voltage, unless sufficiently longintervals and a maximal operating time(switch on time + switch off time) of 5min are observed.

U = applied operating voltageUN = rated voltage or standard voltage

24 V DCED = relative duty cycle (%)

In order to calculate the power requiredin your case, the coil current has to bemeasured. The exact determination ofthe duty cycle is made in our develop-ment laboratories. We would thereforeask you to supply us with the value forcoil current taking into consideration themax. duty cycle requested.

RM 20 – F – 24 V DC 100 % ED

VorzugstypenRMRM

3240

– F –– F –

24 V DC24 V DC

100 % ED100 % ED Preferred types

Hochleistungs-Hubmagnete RMRM

050070

RM 100

W*-OBOOW*-OBOO

– F –– F –

W*-OBOO – F –

24 V DC24 V DC

100 % ED100 % ED

24 V DC 100 % ED

Heavy duty linear solenoids

U

ED100

2.162U = N U

ED100

2.162U = N

* W = waagerechte Kennlinie * W = horizontal characteristics

Page 5: Kuhn Ke Solenoid

Hochleistungs-HubmagnetRM 13

Stoßende und ziehende Ausführung

Heavy Duty Linear SolenoidRM 13

Thrust and pull type

Magnet Hauptkatalog 106 Main catalogue

509

+0,5

≤5

Ø5

M6

6+1

≤348

Ø132

Ø2 Ø1,

5

2,8

3

0 1 2 3 4 5 6S [mm]

F [N

]

0,1

0,2

0,5

10 %ED

100

50

25

5

1

2

5

8

Weight:Complete solenoid: appr. 25 gArmature: appr. 4 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: B (max. permissibletemperature = 130 °C)

Insulation groupaccording to: VDE 0110 B 75Test voltage: 600 V (eff)

Return spring optional.

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 25 g

Anker: ca. 4 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: B (Tgrenz = 130 °C)

Isolationsgruppenach: VDE 0110 B 75Prüfspannung: 600 V (eff)

In Sonderausführung mit eingebauterRückholfeder lieferbar.

Kraft-Weg-Diagramm F = f (s)

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

Bestellformel RM 13 – F – 24 V DC 100 % ED Order specificationsHubmagnetBauart

RM13

Linear solenoidDesign type

Anschlußart

Nennspannung (Standardspannung)1)

Zulässige relative Einschaltdauer bei Luftkühlung (LK)

Litze (Standardlänge 10 cm) F24

100 % ED

Coil terminalsFlying leads (10 cm standard length)

Nominal voltage (standard voltage)1)

Perm. duty cycle under air cooled conditions (LK)1) Die Magnete sind auf Anfrage bis 60 V DC

lieferbar1) Other voltages are available on request up to

60 V DC

Zul. rel. Einschaltdauer (ED)2) % 100 50 25 5 % Perm. duty cycle (ED)2)

Nennaufnahme P 20 W 2,9 5,4 10,1 43,3 W Nominal coil power P 20

2) Bei Montage auf eine Kühlfläche ist eine höhere ED zulässig (bitte anfragen)

2) If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fullyhome position–––––––>Direction of stroke

Page 6: Kuhn Ke Solenoid

Weight:Complete solenoid: appr. 60 gArmature: appr. 12 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: B (max. permissibletemperature = 130 °C)

Insulation groupaccording to: VDE 0110 C 300Test voltage: 800 V (eff)

Service-free DU armature bearing formaximum durability.Return spring optional.

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 60 g

Anker: ca. 12 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: B (Tgrenz = 130 °C)

Isolationsgruppenach: VDE 0110 C 300Prüfspannung: 800 V (eff)

Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer. In Sonderausführung mit eingebauterRückholfeder lieferbar.

Kraft-Weg-Diagramm F = f (s)

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

Hochleistungs-HubmagnetRM 20

Stoßende und ziehende Ausführung

Heavy Duty Linear SolenoidRM 20

Thrust and pull type

Magnet Hauptkatalog 107 Main catalogue

Bestellformel RM 20 – F – 24 V DC 100 % ED Order specificationsHubmagnetBauart

RM20

Linear solenoidDesign type

Anschlußart

Nennspannung (Standardspannung)1)

Litze (Standardlänge 10 cm)Steckhülsenanschluß 2,8 DIN 46247

FM

24

Coil terminalsFlying leads (10 cm standard length)

Nominal voltage (standard voltage)1)

Terminal box (2.8 DIN 46247)

Zulässige relative Einschaltdauer bei Luftkühlung (LK) 100 % ED Perm. duty cycle under air cooled conditions (LK)1) Die Magnete sind auf Anfrage bis 60 V DC

lieferbar1) Other voltages are available on request up to

60 V DC

Zul. rel. Einschaltdauer (ED)2) % 100 45 25 15 5 % Perm. duty cycle (ED)2)

Nennaufnahme P 20Anzugszeit (ED)

Wms

3,911

8 13,5 21 595

Wms

Nominal coil power P 20Actuation time (ED)

2) Bei Montage auf eine Kühlfläche ist eine höhere ED zulässig (bitte anfragen)

2) If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)

0 1 2 3S [mm]

F [N

]

1

2

5

100 %ED

100

45

2515

510

20

50

Ø20

Ø12Ø16

SW14

66,5

M3

288

1278

82

M3

M6

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fullyhome position–––––––>Direction of stroke

Page 7: Kuhn Ke Solenoid

Weight:Complete solenoid: appr. 117 gArmature: appr. 24 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: B (max. permissibletemperature = 130 °C)

Insulation groupaccording to: VDE 0110 B 150Test voltage: 800 V (eff)

Service-free DU armature bearing formaximum durability.Linear force vs. stroke output optional.Return spring optional.

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 117 g

Anker: ca. 24 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: B (Tgrenz = 130 °C)

Isolationsgruppenach: VDE 0110 B 150Prüfspannung: 800 V (eff)

Wartunsfreie Ankerlagerung (DU-Lager)für höchste Lebensdauer.Waagerechte Kennlinie auf Anfrage.In Sonderausführung mit eingebauterRückholfeder lieferbar.

Kraft-Weg-Diagramm F = f (s)

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

Hochleistungs-HubmagnetRM 26

Stoßende und ziehende Ausführung

Heavy Duty Linear SolenoidRM 26

Thrust and pull type

Magnet Hauptkatalog 108 Main catalogue

Bestellformel RM 26 – F – 24 V DC 100 % ED Order specificationsHubmagnetBauart

RM26

Linear solenoidDesign type

Anschlußart

Nennspannung (Standardspannung)1)

Zulässige relative Einschaltdauer bei Luftkühlung (LK)

Litze (Standardlänge 10 cm) F24

100 % ED

Coil terminalsFlying leads (10 cm standard length)

Nominal voltage (standard voltage)1)

Perm. duty cycle under air cooled conditions (LK)1) Die Magnete sind auf Anfrage bis 60 V DC

lieferbar1) Other voltages are available on request up to

60 V DC

Zul. rel. Einschaltdauer (ED)2) % 100 40 25 15 5 % Perm. duty cycle (ED)2)

Nennaufnahme P 20 W 5,5 12,2 18,9 35,3 84 W Nominal coil power P 20

2) Bei Montage auf eine Kühlfläche ist eine höhere ED zulässig (bitte anfragen)

2) If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)

0 1 2 3 4S [mm]

F [N

]

1

2

3

5

100 %ED

100

40

2515

5

10

20

50

Ø26

Ø17Ø19

SW17

72

M3

308

137,58

102

M3

M10

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fullyhome position–––––––>Direction of stroke

Page 8: Kuhn Ke Solenoid

Weight:Complete solenoid: appr. 235 gArmature: appr. 40 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: B (max. permissibletemperature = 130 °C)

Insulation groupaccording to: VDE 0110 B 150Test voltage: 800 V (eff)

Service-free DU armature bearing formaximum durability.Linear force vs. stroke output optional.Return spring optional.

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 235 g

Anker: ca. 40 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: B (Tgrenz = 130 °C)

Isolationsgruppenach: VDE 0110 B 150Prüfspannung: 800 V (eff)

Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer.Waagerechte Kennlinie auf Anfrage.In Sonderausführung mit eingebauterRückholfeder lieferbar.

Kraft-Weg-Diagramm F = f (s)

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

Hochleistungs-HubmagnetRM 32

Stoßende und ziehende Ausführung

Heavy Duty Linear SolenoidRM 32

Thrust and pull type

Magnet Hauptkatalog 109 Main catalogue

Bestellformel RM 32 – F – 24 V DC 100 % ED Order specificationsHubmagnetBauart

RM32

Linear solenoidDesign type

Anschlußart

Nennspannung (Standardspannung)1)

Litze (Standardlänge 10 cm)Steckhülsenanschluß A 2,8 DIN 46247

FM

24

Coil terminalsFlying leads (10 cm standard length)

Nominal voltage (standard voltage)1)

Terminal box 2.8 DIN 46247

Zulässige relative Einschaltdauer bei Luftkühlung (LK) 100 % ED Perm. duty cycle under air cooled conditions (LK)

RM 32-F

24VDC 100% ED

1) Die Magnete sind auf Anfrage bis 60 V DClieferbar

1) Other voltages are available on request up to 60 V DC

Zul. rel. Einschaltdauer (ED)2) % 100 70 45 25 15 5 % Perm. duty cycle (ED)2)

Nennaufnahme P 20Anzugszeit (ED)

Wms

6529

10 16 24 48 12211

Wms

Nominal coil power P 20Actuation time (ED)

2) Bei Montage auf eine Kühlfläche ist eine höhere ED zulässig (bitte anfragen)

2) If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)

0 2 4 6 8S [mm]

F [N

]

1

2

5

100 %ED

100

50

251510

5

10

20

50

Ø1824

M3

94

M4

4510

24114 102

M4

Ø18

Ø32

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fullyhome position–––––––>Direction of stroke

Page 9: Kuhn Ke Solenoid

Weight:Complete solenoid: appr. 380 gArmature: appr. 60 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: B (max. permissibletemperature = 130 °C)

Insulation groupaccording to: VDE 0110 C 300Test voltage: 2500 V (eff)

Service-free DU armature bearing formaximum durability.Linear force vs. stroke output optional.Return spring optional.

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 380 g

Anker: ca. 60 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: B (Tgrenz = 130 °C)

Isolationsgruppenach: VDE 0110 C 300Prüfspannung: 2500 V (eff)

Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer.Waagerechte Kennlinie auf Anfrage.In Sonderausführung mit eingebauterRückholfeder lieferbar.

Kraft-Weg-Diagramm F = f (s)

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

Hochleistungs-HubmagnetRM 40

Stoßende und ziehende Ausführung

Heavy Duty Linear SolenoidRM 40

Thrust and pull type

Magnet Hauptkatalog 110 Main catalogue

Bestellformel RM 40 – F – 24 V DC 100 % ED Order specificationsHubmagnetBauart

RM40

Linear solenoid seriesDesign type

Anschlußart

Nennspannung (Standardspannung)1)

Litze (Standardlänge 10 cm)Steckhülsenanschluß (6,3 DIN 46247)

FN

24

Coil terminalsFlying leads (10 cm standard length)

Nominal voltage (standard voltage)1)

Terminal box (6.3 DIN 46247)

Zulässige relative Einschaltdauer bei Luftkühlung (LK) 100 % ED Perm. duty cycle under air cooled conditions (LK)

RM40 - F

24VDC100 %ED

1) Die Magnete sind auf Anfrage bis 230 V DClieferbar

1) Other voltages are available on request up to230 V DC

Zul. rel. Einschaltdauer (ED)2) % 100 75 45 25 15 5 % Perm. duty cycle (ED)2)

Nennaufnahme P 20Anzugszeit (ED)

Wms

1136

13,5 21 34 54 16511

Wms

Nominal coil power P 20Actuation time (ED)

2) Bei Montage auf eine Kühlfläche ist eine höhere ED zulässig (bitte anfragen)

2) If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)

0 2 4 6 8S [mm]

F [N

]

1

2

5

100 %ED

10075

4525

15

5

10

20

50

Page 10: Kuhn Ke Solenoid

Hochleistungs-HubmagnetRM 40

Stoßende und ziehende Ausführung

Heavy Duty Linear SolenoidRM 40

Thrust and pull type

Magnet Hauptkatalog 111 Main catalogue

Ø22Ø30Ø40

M4

110

M5

2

4512

32165 122

M5

Ø20

Ø22

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Page 11: Kuhn Ke Solenoid

Magnet Hauptkatalog 112 Main catalogue

Page 12: Kuhn Ke Solenoid

Coil terminals

Examples of design types:without end stopwithout stoke limit in the open position

Anschlußarten

Beispiele für Ausführungen:Ohne Anschlagdeckel;keine Hubbegrenzung im offenen Zustand

Hochleistungs-HubmagneteRM 050 ... RM 100

Heavy Duty Linear SolenoidsRM 050 ... RM 100

Magnet Hauptkatalog 113 Main catalogue

–OBOO– –OBLO– –OBOR– –ORRO– –OROR–

–HBOO– –HBLO– –HBOL– –HRRO– –HROR–

Bestellformel RM 070 – W – O R O R – N – 24 V DC 100 % ED Order specificationsHubmagnetBauart ø mm

RM050

Linear solenoid seriesDesign type ø mm

060070080090

bis 160 mm auf AnfrageWaagerechte Kraft-Weg-KennlinieAusführung2)

Hubbegrenzung ohnemit

Stößel rechts3)

beidseitig

1001601)

W

OH

RB

160 mm optionalHorizontal frontal force vs. stroke outputDescription2)

Stroke limit

Plunger

withoutwithright hand side3)

both sidesFlansch ohne

rechts3)

Faltenbalglinks4)

ohne

Anschlußart

rechts3)

links4)

beidseitig5)

Litze (Standardlänge 20 cm)

NennspannungGerätestecker6) 24 V DC205 V DC (an 230 V ACnach SI-Gleichrichter-brücke)

Zulässige relative Einschaltdauer bei Luftkühlung (LK)

ORL

ORLB

F

Flange

Gaiter

Coil terminals

N24

205Operating voltage

100 % ED Perm. duty cycle under air cooled conditions (LK)

withoutright hand side3)

left hand side4)

withoutright hand side3)

left hand side4)

both sides5)

Flying leads (20 cm standard length)plug-in socket connection6) 24 V DC205 V DC (connected to230 V AC with SI- bridgerectifier)

1) Bis 160 mm auf Anfrage2) Siehe unten3) Entgegengesetzt zur elektr. Anschlußseite4) An der elektr. Anschlußseite5) Nur mit Hubbegrenzung lieferbar6) Für Steckhülse 6,3 DIN 46247 und

Gerätesteckdose Z 801 und Z 811Zubehör siehe Seite 130-131

1) Up to 160 mm optional2) See below3) Opposite to electrical connection4) Same side as electrical connection5) Available only with stroke limit6) For plug-in socket 6.3 DIN 46247 and plug

Z 801 and Z 811Accessories see pages 130-131

N F

ca.1

2ca

.12

200

+15

Page 13: Kuhn Ke Solenoid

Hochleistungs-Hubmagnet RM 050

Gewicht:Magnet: ca. 610 g

Anker: ca. 200 gStandard:

Spannung: 24 V DCLitze: 20 cm

Isolierstoffklasse: F (Tgrenz = 155 °C)

Isolationsgruppenach: VDE 0110 C 450Prüfspannung: 2500 V (eff)

Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer. Bei Ausführung mit Standard-Hubbe-grenzung Hub 10 mm. In Sonderausführung mit eingebauterRückholfeder lieferbar.

Kraft-Weg-Diagramm F = f (s)

W = Waagerechte Kennlinie

Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen, bestromtenZustand

Hochleistungs-HubmagnetRM 050

Heavy Duty Linear SolenoidRM 050

Heavy duty linear solenoid RM 050

Weight:Complete solenoid: appr. 610 gArmature: appr. 200 g

Standard:Voltage: 24 V DCFlying leads: 20 cm

Insulation class: F (max. permissibletemperature = 155 °C)

Insulation groupaccording to: VDE 0110 C 450Test voltage: 2500 V (eff)

Service-free DU armature bearing formaximum durability. Stroke of version with standard strokelimiter: 10 mm.Return spring optional.

Force vs. Stroke diagramm F = f (s)

W = horizontal characteristic

Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature

stroke s = 0 corresponds to armature in fully homeposition

Magnet Hauptkatalog 114 Main catalogue

Zul. rel. Einschaltdauer (ED)1) % 100 60 35 25 15 5 % Perm. duty Cycle (ED)1)

Nennaufnahme P 20Anzugszeit (ED)

Wms

2040

30 55 70 115 30015

Wms

Nominal coil power P 20Actuation time (ED)

1) Bei Montage auf eine Kühlfläche ist eine höhereED zulässig (bitte anfragen)

1) If solenoid is mounted directly onto a flat metalsurface the duty cycle can be extended (pleaseask for advice)

0 2 4 6 8 10S [mm]

F [N

]

10

20

50

1000 %ED

100

60

352515

5100

200

500

Page 14: Kuhn Ke Solenoid

Hochleistungs-HubmagnetRM 050

Heavy Duty Linear SolenoidRM 050

Magnet Hauptkatalog 115 Main catalogue

M5

M5

Ø30

165

325

5M

4

173019 50

42

5041

516

Ø34

50

736

5713

5

Ø4,

8

Ø50

Ø40

Ø30

Ø50

Ø40

M5

M5

Ø30

10

1628

532

55

M4

323019 50

42

65

16

Ø34

Ø34

65

7

72

Ø4,

8

Ø30

Hub

richt

ung

Hub

richt

ung

Direction of stroke

Direction of stroke

ohne Anschlagdeckel without end stop

mit Anschlagdeckel with end stop

Page 15: Kuhn Ke Solenoid

Hochleistungs-Hubmagnet RM 060

Gewicht:Magnet: ca. 1300 g

Anker: ca. 250 gStandard:

Spannung: 24 V DCLitze: 20 cm

Isolierstoffklasse: F (Tgrenz = 155 °C)

Isolationsgruppenach: VDE 0110 C 450Prüfspannung: 2500 V (eff)

Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer. Bei Ausführung mit Standard-Hubbe-grenzung Hub 12 mm. In Sonderausführung mit eingebauterRückholfeder lieferbar.

Kraft-Weg-Diagramm F = f (s)

W = Waagerechte Kennlinie

Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen, bestromtenZustand

Hochleistungs-HubmagnetRM 060

Heavy Duty Linear SolenoidRM 060

Heavy duty linear solenoid RM 060

Weight:Complete solenoid: appr. 1300 gArmature: appr. 250 g

Standard:Voltage: 24 V DCFlying leads: 20 cm

Insulation class: F (max. permissibletemperature = 155 °C)

Insulation groupaccording to: VDE 0110 C 450Test voltage: 2500 V (eff)

Service-free DU armature bearing formaximum durability. Stroke of version with standard strokelimiter: 12 mm.Return spring optional.

Force vs. Stroke diagramm F = f (s)

W = horizontal characteristic

Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature

stroke s = 0 corresponds to armature in fully homeposition

Magnet Hauptkatalog 116 Main catalogue

Zul. rel. Einschaltdauer (ED)1) % 100 40 25 15 5 % Perm. duty Cycle (ED)1)

Nennaufnahme P 20Anzugszeit (ED)

Wms

2545

60 98 150 38117

Wms

Nominal coil power P 20Actuation time (ED)

1) Bei Montage auf eine Kühlfläche ist eine höhereED zulässig (bitte anfragen)

1) If solenoid is mounted directly onto a flat metalsurface the duty cycle can be extended (pleaseask for advice)

0 5 10 12 15S [mm]

F [N

]

10

20

50

1000 %ED

100

4025

15

5

100

200

500

Page 16: Kuhn Ke Solenoid

Hochleistungs-HubmagnetRM 060

Heavy Duty Linear SolenoidRM 060

Magnet Hauptkatalog 117 Main catalogue

2934

M6

M6

Ø35

1837

541

57

17

64

718

Ø36

65

8

72152

Ø36

M6

M5

3019 67

54

Ø5,

8

Ø60

Ø45

Ø35

M6

M6

Ø35

10

1829

541

57

34

81

18

Ø36

82

8

89

Ø36

M6

M5

3019 67

54

Ø5,

8

Ø60

Ø45

Ø35

Hub

richt

ung

Hub

richt

ung

Direction of stroke

Direction of stroke

ohne Anschlagdeckel without end stop

mit Anschlagdeckel with end stop

Page 17: Kuhn Ke Solenoid

Hochleistungs-Hubmagnet RM 070

Gewicht:Magnet: ca. 2000 g

Anker: ca. 400 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: F (Tgrenz = 155 °C)

Isolationsgruppenach: VDE 0110 C 450Prüfspannung: 2500 V (eff)

Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer. Bei Ausführung mit Standard-Hubbe-grenzung Hub 15 mm. In Sonderausführung mit eingebauterRückholfeder lieferbar.

Kraft-Weg-Diagramm F = f (s)

W = Waagerechte Kennlinie

Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen, bestromtenZustand

Hochleistungs-HubmagnetRM 070

Heavy Duty Linear SolenoidRM 070

Heavy duty linear solenoid RM 070

Weight:Complete solenoid: appr. 2000 gArmature: appr. 400 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: F (max. permissibletemperature = 155 °C)

Insulation groupaccording to: VDE 0110 C 450Test voltage: 2500 V (eff)

Service-free DU armature bearing formaximum durability. Stroke of version with standard stroke limiter: 15 mm.Return spring optional.

Force vs. Stroke diagramm F = f (s)

W = horizontal characteristic

Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature

stroke s = 0 corresponds to armature in fully homeposition

Magnet Hauptkatalog 118 Main catalogue

Zul. rel. Einschaltdauer (ED)1) % 100 40 25 15 5 % Perm. duty Cycle (ED)1)

Nennaufnahme P 20Anzugszeit (ED)

Wms

3154

78 121 198 47225

Wms

Nominal coil power P 20Actuation time (ED)

1) Bei Montage auf eine Kühlfläche ist eine höhereED zulässig (bitte anfragen)

1) If solenoid is mounted directly onto a flat metalsurface the duty cycle can be extended (pleaseask for advice)

0 5 10 15 20S [mm]

F [N

]

10

20

50

1000 %ED

100

40

2515

5

100

200

500

Page 18: Kuhn Ke Solenoid

Hochleistungs-HubmagnetRM 070

Heavy Duty Linear SolenoidRM 070

Magnet Hauptkatalog 119 Main catalogue

M8

10

2034

549

58

39

93

20

Ø43

94

10

103

Ø43

3019 80

62

Ø7

M8Ø38

M5

Ø70

Ø52

Ø38

Hub

richt

ung

Hub

richt

ung

Direction of stroke

Direction of stroke

ohne Anschlagdeckel without end stop

mit Anschlagdeckel with end stop

M8

M8

2043

549

58

20

74

820 34

Ø38

Ø43

75

10

84177

Ø43

39

M5

3019 80

62

Ø7

Ø70

Ø52

Ø38

Page 19: Kuhn Ke Solenoid

Hochleistungs-Hubmagnet RM 080

Gewicht:Magnet: ca. 2900 g

Anker: ca. 500 gStandard:

Spannung: 24 V DCLitze: 20 cm

Isolierstoffklasse: F (Tgrenz = 155 °C)

Isolationsgruppenach: VDE 0110 C 450Prüfspannung: 2500 V (eff)

Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer. Bei Ausführung mit Standard-Hubbe-grenzung Hub 20 mm. In Sonderausführung mit eingebauterRückholfeder lieferbar.

Kraft-Weg-Diagramm F = f (s)

W = Waagerechte Kennlinie

Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen, bestromtenZustand

Hochleistungs-HubmagnetRM 080

Heavy Duty Linear SolenoidRM 080

Heavy duty linear solenoid RM 080

Weight:Complete solenoid: appr. 2900 gArmature: appr. 500 g

Standard:Voltage: 24 V DCFlying leads: 20 cm

Insulation class: F (max. permissibletemperature = 155 °C)

Insulation groupaccording to: VDE 0110 C 450Test voltage: 2500 V (eff)

Service-free DU armature bearing formaximum durability. Stroke of version with standard strokelimiter: 20 mm.Return spring optional.

Force vs. Stroke diagramm F = f (s)

W = horizontal characteristic

Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature

stroke s = 0 corresponds to armature in fully homeposition

Magnet Hauptkatalog 120 Main catalogue

Zul. rel. Einschaltdauer ED)1) % 100 45 25 15 5 % Perm. duty Cycle (ED)1)

Nennaufnahme P 20Anzugszeit (ED)

Wms

3775

94 149 226 68534

Wms

Nominal coil power P 20Actuation time (ED)

1) Bei Montage auf eine Kühlfläche ist eine höhereED zulässig (bitte anfragen)

1) If solenoid is mounted directly onto a flat metalsurface the duty cycle can be extended (pleaseask for advice)

0 5 10 15 20 25S [mm]

F [N

]

10

20

50

1000 %ED

100452515

5

100

200

500

Page 20: Kuhn Ke Solenoid

Hochleistungs-HubmagnetRM 080

Heavy Duty Linear SolenoidRM 080

Magnet Hauptkatalog 121 Main catalogue

Ø45

Ø50

Ø50

M10

M10M10

85

23

9,5

9,5

655

5

8412

50 45 30

96216

30

19 30

Ø62

Ø80 7290Ø45

M5

Ø9,

5

Ø50

Ø50

M10

M10

M10

110

4810

9,5

2565

55

109

1250 45 30

12124

1

30

19 30Ø62

Ø80 7290Ø45

M5

Ø9,

5Ø45

Hub

richt

ung

Hub

richt

ung

Direction of stroke

Direction of stroke

ohne Anschlagdeckel without end stop

mit Anschlagdeckel with end stop

Page 21: Kuhn Ke Solenoid

Hochleistungs-Hubmagnet RM 090

Gewicht:Magnet: ca. 4500 g

Anker: ca. 800 gStandard:

Spannung: 24 V DCLitze: 20 cm

Isolierstoffklasse: F (Tgrenz = 155 °C)

Isolationsgruppenach: VDE 0110 C 600Prüfspannung: 2500 V (eff)

Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer. Bei Ausführung mit Standard-Hubbe-grenzung Hub 25 mm. In Sonderausführung mit eingebauterRückholfeder lieferbar.

Kraft-Weg-Diagramm F = f (s)

W = Waagerechte Kennlinie

Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen, bestromtenZustand

Hochleistungs-HubmagnetRM 090

Heavy Duty Linear SolenoidRM 090

Heavy duty linear solenoid RM 090

Weight:Complete solenoid: appr. 4500 gArmature: appr. 800 g

Standard:Voltage: 24 V DCFlying leads: 20 cm

Insulation class: F (max. permissibletemperature = 155 °C)

Insulation groupaccording to: VDE 0110 C 600Test voltage: 2500 V (eff)

Service-free DU armature bearing formaximum durability. Stroke of version with standard strokelimiter: 25 mm.Return spring optional.

Force vs. Stroke diagramm F = f (s)

W = horizontal characteristic

Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature

stroke s = 0 corresponds to armature in fully homeposition

Magnet Hauptkatalog 122 Main catalogue

Zul. rel. Einschaltdauer( ED)1) % 100 40 25 15 5 % Perm. duty Cycle (ED)1)

Nennaufnahme P 20Anzugszeit (ED)

Wms

5185

102 194 303 74838

Wms

Nominal coil power P 20Actution time (ED)

1) Bei Montage auf eine Kühlfläche ist eine höhereED zulässig (bitte anfragen)

1) If solenoid is mounted directly onto a flat metalsurface the duty cycle can be extended (pleaseask for advice)

0 5 10 15 20 25 30S [mm]

F [N

]

10

20

50

2000 %ED

100

402515

5

100

200

500700

1000

Page 22: Kuhn Ke Solenoid

Hochleistungs-HubmagnetRM 090

Heavy Duty Linear SolenoidRM 090

Magnet Hauptkatalog 123 Main catalogue

Ø55

Ø55Ø52

M12

M12

95

23

1111

4080

55

66

9412

60 55

106251

40

19 30

Ø68

Ø90 8010

0

Ø52

M6

Ø9,

5

Ø55

Ø55Ø52

124

12

136

19 30

Ø68

Ø90 8010

0

Ø52

M6

Ø9,

5

M12

M12

125

53

1140

805

555

40

12

Hub

richt

ung

Hub

richt

ung

Direction of stroke

Direction of stroke

ohne Anschlagdeckel without end stop

mit Anschlagdeckel with end stop

Page 23: Kuhn Ke Solenoid

Hochleistungs-Hubmagnet RM 100

Gewicht:Magnet: ca. 6400 g

Anker: ca. 1100 gStandard:

Spannung: 24 V DCLitze: 20 cm

Isolierstoffklasse: F (Tgrenz = 155 °C)

Isolationsgruppenach: VDE 0110 C 450Prüfspannung: 2500 V (eff)

Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer. Bei Ausführung mit Standard-Hubbe-grenzung Hub 30 mm. In Sonderausführung mit eingebauterRückholfeder lieferbar.

Kraft-Weg-Diagramm F = f (s)

W = Waagerechte Kennlinie

Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen, bestromtenZustand

Hochleistungs-HubmagnetRM 100

Heavy Duty Linear SolenoidRM 100

Heavy duty linear solenoid RM 100

Weight:Complete solenoid: appr. 6400 gArmature: appr. 1100 g

Standard:Voltage: 24 V DCFlying leads: 20 cm

Insulation class: F (max. permissibletemperature = 155 °C)

Insulation groupaccording to: VDE 0110 C 450Test voltage: 2500 V (eff)

Service-free DU armature bearing formaximum durability. Stroke of version with standard strokelimiter: 30 mm.Return spring optional.

Force vs. Stroke diagramm F = f (s)

W = horizontal characteristic

Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature

stroke s = 0 corresponds to armature in fully homeposition

Magnet Hauptkatalog 124 Main catalogue

Zul. rel. Einschaltdauer (ED)1) % 100 40 25 15 5 % Perm. duty Cycle (ED)1)

Nennaufnahme P 20Anzugszeit (ED)

Wms

69110

162 255 400 107145

Wms

Nominal coil power P 20Actution time (ED)

1) Bei Montage auf eine Kühlfläche ist eine höhereED zulässig (bitte anfragen)

1) If solenoid is mounted directly onto a flat metalsurface the duty cycle can be extended (pleaseask for advice)

0 10 20 30 40S [mm]

F [N

]

10

20

50

2000 %ED

40

100

2515

5

100

200

500700

1000

Page 24: Kuhn Ke Solenoid

Hochleistungs-HubmagnetRM 100

Heavy Duty Linear SolenoidRM 100

Magnet Hauptkatalog 125 Main catalogue

Ø60

Ø60

Ø58

M12

M12 M12

110

24

1212

5095

66

77

109

1371 65

122294

50

19 30

Ø76

Ø10

0

88110

Ø58

M8

Ø11

,5

Ø60

Ø60Ø58

M12

M12

144

58

1250

956

665

143

13

156

50

1419 30

Ø76

Ø10

0

88110

Ø58

M8

Ø11

,5

Hub

richt

ung

Hub

richt

ung

Direction of stroke

Direction of stroke

ohne Anschlagdeckel without end stop

mit Anschlagdeckel with end stop

Page 25: Kuhn Ke Solenoid

Weight:Complete solenoid: appr. 105 gArmature: appr. 19 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: B (max. permissibletemperature = 130 °C)

Insulation groupaccording to: VDE 0110 C 75Test voltage: 800 V (eff)

Long life expectancy through plasticbobbin armature bearing.

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 105 g

Anker: ca. 19 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: B (Tgrenz = 130 °C)

Isolationsgruppenach: VDE 0110 C 75Prüfspannung: 800 V (eff)

Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer.

Kraft-Weg-Diagramm F = f (s)

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hochleistungs-Umkehr-HubmagnetURM 20

Heavy Duty Two-DirectionalLinear Solenoid URM 20

Magnet Hauptkatalog 126 Main catalogue

Bestellformel URM 20 – F – 24 V DC 100 % ED Order specificationsHubmagnetBauart

URM20

Linear solenoidDesign type

Anschlußart

Nennspannung (Standardspannung)1)

Zulässige relative Einschaltdauer bei Luftkühlung (LK)

Litze (Standardlänge 10 cm) F24

100 % ED

Coil terminalsFlying leads (10 cm standard length)

Nominal voltage (standard voltage)1)

Perm. duty cycle under air cooled conditions (LK)1) Die Magnete sind auf Anfrage bis 60 V DC

lieferbar1) Other voltages are available on request up to

60 V DC

Zul. rel. Einschaltdauer (ED)2) % 100 45 25 15 5 % Perm. duty cycle (ED)2)

Nennaufnahme P 20Anzugszeit (ED)

Wms

3,911

8 13,5 21 595

Wms

Nominal coil power P 20Actuation time (ED)

2) Bei Montage auf eine Kühlfläche ist eine höhere ED zulässig (bitte anfragen)

2) If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)

0 1 2 3S [mm]

F [N

]

1

2

5

100 %ED

100

452515

510

20

50

Page 26: Kuhn Ke Solenoid

Hochleistungs-Umkehr-HubmagnetURM 20

Heavy Duty Two-DirectionalLinear Solenoid URM 20

Magnet Hauptkatalog 127 Main catalogue

M3

M8

M3

9855 2220

9

96 Ø20

Ø16

SW14

2121

+0,6–0,2

±0,5

1 2

Maße gelten, wenn System 1 bestromt

<–––––––>Hubrichtung

Dimensions given when system 1 current-carrying<–––––––>Direction of stroke

Page 27: Kuhn Ke Solenoid

Weight:Complete solenoid: appr. 1200 gArmature: appr. 180 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: B (max. permissibletemperature = 130 °C)

Insulation groupaccording to: VDE 0110 C 75Test voltage: 2500 V (eff)

Long life expectancy through plasticbobbin armature bearing.

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 1200 g

Anker: ca. 180 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: B (Tgrenz = 130 °C)

Isolationsgruppenach: VDE 0110 C 75Prüfspannung: 2500 V (eff)

Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer.

Kraft-Weg-Diagramm F = f (s)

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

Hochleistungs-Umkehr-HubmagnetURM 50

Heavy Duty Two-DirectionalLinear Solenoid URM 50

Magnet Hauptkatalog 128 Main catalogue

Bestellformel URM 50 – N – 24 V DC 100 % ED Order specificationsHubmagnetBauart

URM50

Linear solenoidDesign type

Anschlußart

Nennspannung (Standardspannung)2)

Litze (Standardlänge 10 cm)Gerätestecker1)

FN

24

Coil terminalsFlying leads (10 cm standard length)

Nominal voltage (standard voltage)2)

Plug-in socket connection1)

Zulässige relative Einschaltdauer bei Luftkühlung (LK) 100 % ED Perm. duty cycle under air cooled conditions (LK)

URM50-N

24V = 100

% ED

1) Für Steckhülsen 6,3 DIN 462472) Die Magnete sind auf Anfrage bis 230 V DC

lieferbar

1) For socket 6.3 DIN 46247 2) Other voltages are available on request up to

230 V DC

Zul. rel. Einschaltdauer (ED)3) % 100 70 40 25 15 5 % Perm. duty cycle (ED)3)

Nennaufnahme P 20 W 15 24 38 56 89 280 W Nominal coil power P 203) Bei Montage auf eine Kühlfläche ist eine höhere ED zulässig (bitte anfragen)

3) If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)

0 2 4 6 8S [mm]

F [N

]

10

20

50

1000 %ED

10070

402515

5100

200

500

Page 28: Kuhn Ke Solenoid

Hochleistungs-Umkehr-HubmagnetURM 50

Heavy Duty Two-DirectionalLinear Solenoid URM 50

Magnet Hauptkatalog 129 Main catalogue

15610430

M5

M5 1515

ca.52

Ø40

30

Ø50

M4

ca.6

0ca

.72

1 2

19

Maße gelten, wenn System 1 bestromt

<–––––––>Hubrichtung

Dimensions given when system 1 current-carrying<–––––––>Direction of stroke

Page 29: Kuhn Ke Solenoid

Plug-in socket for the applianceScrew joint PG 9for lead diameter 6-8 mm

Plug-in socket Z 811Plug-in socket with built-inSi-bridge rectifierType GDML 211-GB 1

Obtainable from:Firma Richard HirschmannPO Box 11073728 Esslingen

Flange(Mounting screws are part of theshipment)

Order specification

Gerätesteckdose Z 801Kabelverschraubung SPG 9für Kabeldurchmesser 6-8 mm

Gerätesteckdose Z 811Gerätesteckdose mit eingebautemSi-BrückengleichrichterTyp GDML 211-GB 1

Zu beziehen bei:Firma Richard HirschmannPostfach 11073728 Esslingen

Flansch(Befestigungsschrauben werden mitgeliefert)

Bestellbezeichnung

Hochleistungs-HubmagneteZubehör Typ RM

Heavy Duty Linear SolenoidsAccessories for Series RM

Magnet Hauptkatalog 130 Main catalogue

AKL

CB

H

ØE

ØF

ØD

ØI

ØJ

ØG

Bestell- Maße (mm) Dimensions (mm) OrderNr.

Z 839Typ

RM 050A

50,0B7,0

C12,0

D30,0

E23,0

F30,0

G–

H–

I4,8

J4,3

K42,0

L40,0

TypeRM 050

numberZ 839

Z 840Z 841Z 842Z 843

RM 060RM 070

70,080,0

RM 080RM 090

90,0100,0

8,010,0

13,015,0

12,012,0

17,017,0

35,038,0

29,032,5

45,052,0

38,043,0

35,038,0

60,570,5

45,052,0

80,590,5

1,01,0

5,87,0

1,01,0

9,59,5

5,35,3

54,062,0

6,46,4

72,080,0

45,052,0

RM 060RM 070

62,068,0

RM 080RM 090

Z 840Z 841Z 842Z 843

Z 844 RM 100 110,0 13,0 19,0 58,0 49,0 58,0 100,5 1,0 11,5 8,4 88,0 76,0 RM 100 Z 844

27,5M3

53

PG9

Ø22

,5

353,

5

16

Page 30: Kuhn Ke Solenoid

End stop(Mounting screws are part of theshipment)

Order specification

Fork

1) Forks are galvanised and chromed yellow.Supplied without a nut. Secure using e.g. Loctiteor a simular product.

2) Further specifications (> M10) optional

Gaiters see accessories page 9

Anschlagdeckel(Befestigungsschrauben werden mitgeliefert)

Bestellbezeichnung

Gabelkopf

1) Gabelköpfe, verzinkt und gelb chromatiert,werden ohne Mutter geliefert. Sicherung z. B.durch Loctite o.ä.

2) Weitere Ausführungen (> M10) auf Anfrage

Faltenbalge siehe Zubehör-Übersicht,Seite 9

Hochleistungs-HubmagneteZubehör Typ RM

Heavy Duty Linear SolenoidsAccessories for Series RM

Magnet Hauptkatalog 131 Main catalogue

ØA

ØF

ØE

ØB

GH

DC

KI

ØJ

A

C

F

G

E

ØD

B

Bestell- Maße (mm) Dimensions (mm) OrderNr.

Z 838Typ

RM 050A

50,0B

40,0C

20,0D

15,0E

23,0F

30,0G5,5

H11,0

IM4

J4,3

K10,0

TypeRM 050

numberZ 838

Z 845Z 846Z 847Z 848

RM 060RM 070

60,070,0

RM 080RM 090

80,090,0

45,052,0

22,024,0

62,068,0

30,035,0

17,019,0

29,033,0

25,030,0

38,043,0

35,038,0

5,55,5

45,052,0

5,55,5

12,015,0

M5M5

20,025,0

M5M6

5,35,3

10,010,0

5,36,4

10,012,0

RM 060RM 070

Z 845Z 846

RM 080RM 090

Z 847Z 848

Z 849 RM 100 100,0 76,0 40,0 34,0 48,0 58,0 6,5 30,0 M8 8,4 14,0 RM 100 Z 849

Bestell-Nr.

Order-number

A B C D E F

An-schluß2)

Connec-tion G

38.30437.304

1223

1529

916

2,55

3,15

610

M3M5

36.30435.3041)

34.3042)

2732

3442

40 52

1926

68

32 10

68

1216

10 20

M6M8

M10

Page 31: Kuhn Ke Solenoid

Magnet Hauptkatalog 132 Main catalogue