Ks 306 Motion Sensor user's manual

2

Click here to load reader

description

Security Solution of indoor wireless motion detector, pet immunity body sensor, home alarm systems, home security systems, alarm control systems, remote home monitor, Infrared detector, home protection systems, wireless alarm systems. Guide to install home or office indoor security alarm systems, intrusion detection parts, detectors to installed for window, downstairs, hallways, inside rooms security equipment, security & protection devices.

Transcript of Ks 306 Motion Sensor user's manual

Page 1: Ks 306 Motion Sensor user's manual

KS-306FCT wireless curtain passive infrared detector adoptsadvanced illegible logic intelligent recognising technology. It can detectthe intruder crossing the defence area. It is with automatic temperaturecompensation and intelligent direction recognising function. It has theadvantage of low rate of false alarm, stable and easy installation in thewindow, aisle and so on.

Anti- electromagnetic interference and spotlight; pet immune and lowfalse alarm

*The static current is particularly small, and two pieces of size“AA” dry battery can be used for one year*Two levels sensitivity setup, temperature compensation.*One-way or two ways (direction) alarm are available.*Directional recognition and time are adjustable in one-way mode.*Easily installed on the wall or ceiling.*Wireless transmission adopts SAWF

*

1.Main functions and features

2.Cover opening

Insert the “-” screwdriverupright to the back hole ofthe unit

Remove the cover andinstall the battery or setif need

(1) Open

(2) Close

Match the hole of cover and press to close

(3)

(4)

8

KS-306FCT Wireless Curtain PIR Detector

-1-

- -2 - -3

KS-306FCT

KS-306FCT KS-306FCT

V2.0

Transmitter jumper: be used for transmitting only.Indicator:

Flash once: power on and initializingFlash twice: finish initializtion/returning time arrival or trigger againin returning timeFlash three times: when detecting intruder, it will send alarm signal topanelFlash five times: when detecting person goes from inside to outside, itwon't send alarm signal to panel.Flash once every five seconds: battery low, please replace batteryimmediately.Flash once per five seconds: low power

Infrared sensor: to detect the body infrared signal, it required to keepin cleanness

Detective distance option(JP5)Jumper inserted: high sensibility, detective distance is 1-8m(default)Jumper removed: low sensibility, detective distance is 1-4m Pleasechoose the low sensibility if it meets the requirement

Anti-temper switch: when shell be opened and destroyed, the detectorwill alarm

Battery case: put in two pieces of size “ AA” dry battery with the rightpolarity as picture

Function jumper:Jp1: Mode option: to choose the working mode

Users’ Manual

3.Component Description

Unclench the screwdriverand the open the cover

No Alarm

Alarm

×

(Note) (5)

Alarm in two directions

A B

(6)

Alarm in one direc tion Mode 1

×

A B

(7)

×√

A B

Alarm in one direc tion Mode 2

PDF created with pdfFactory trial version www.pdffactory.com

Page 2: Ks 306 Motion Sensor user's manual

×

Window and door

(8)

Air-condition

×(9)

Body Moving

×(10)

Carbinet

Barrier

×(11)

Ceiling

WallWall

(12) Installation

100°

(13) (14) (15) (16)

6.Technical Parameter

Detective distance: <8 mDetective angle: as picture 5 and 12Working voltage: DC3V(2pcs, Size AA dry battery 1.5V)Initialization time: 20-120 secondsStandby current: <60u AEmission frequency:433.92MHzWorking temperature: -10C-+50CWireless distance:1-400m(in the open area)Time between two alarm: >8sSize: 110mmX70mmX40MMNet weight: 103g(without battery)

-7-

- -4 - -5

- -6

KS-306FCT KS-306FCT

KS-306FCTKS-306FCT

Jumper removed:

Jumper inserted:alarm in one direction, as picture 6 and 7, it will alarmonly in one direction, which depends on the Jp2

JP2: Direction option: to choose the direction when alarm in onedirection (only available for one direction mode)Jumper Removed:one direction mode 1, as picture 6, it will alarm fromA to B but not B to A (default)Jumper inserted:one direction mode 2, as picture 7, it will alarm from Bto A but not A to BIt will be an opposite alarm direction with the JP2 jumper and without

JP3: Returning time: to set up the longest lasting time when the personcomes across from one direction to another before returning back.(onlyavailable for one direction mode in JP1)Jumper removed: 15 seconds (default)Jumper inserted:4 minutesEg: In JP1 Mode with jumper inserted (alarm in one direction), In JP2mode with jumper removed (one direction mode 1, pic 6), in JP3 modewith jumper removed (maximum 15 seconds), as picture 6If person comes from A to B, it will alarmIf person comes from B to A, the detector will count the time and has twocases:The detector won’t alarm if the person comes back from A to B within 15secondsThe detector will alarm if the person comes back from A to B beyond 15seconds

Wireless addressable code: not need to change it unless needed , Ifneeded please do it under the professional instruction.

alarm in two directions, as picture 5,it will alarmboth from A to B and B to A (default)

4.Installation requirementAs picture 8, stand off from the door and windows,,stand off the

straight light (eg. Spotlight)As picture 9, the detector is sensitive with the air convection and

temperature, so stand off the warm or cold sources and heavy airconvection, eg.,air flowing place, air-condition,electric radiators,door andwindows, etc.

The infrared detector has the highest sensitivity when a human bodymoves parallel with the detector , pic 5, and the sensitivity is the lowestwhen vertically against the detector, pic 10.

There is no barrier within the defended area of a detector, as pic 11Choose the best location according to the requirement.

5.Installation and being used

Open the shell and set if needed, pic 1

Put in the battery with the right polarity as picture 3, the indicator flash

once, and it begins to initialize

It finishes the initialization with flash twice. Then register the detector

to the panel (utilizing the anti-temper switch to trigger detector is

available). Arm the panel, and trigger the anti-temper (press the anti-

temper metal bar for 2 seconds and loosen it), the detector will emit the

signal and flash three times, and the panel alarms, that is finished. If

failure, try again.

Cover the shell, as pic 2, have a motion about 20cm in front of

detector to create a simulative alarm to test, if it is not meet the

requirement, it have to reset.

Fasten the mounting bracket on the required place with nail or

screw, pic 13, and then mount the detector on the bracket, as pic

14, adjust the angle and screw the bearer . Then put out the

full antennas to reach the better effect.

Create a simulative alarm:arm the panel, after initialization, the human

body move across the detector, as pic 6 and 7, and the indicator will flash

bearer

in the bracket

3 times, then the panel alarms. disarm the panel immediately and armagain, come across the detector after waiting for 8 seconds, and see if italarms again. If it alarms in some times when testing, it is ok and can beused.If simulative test is failure, please check the setting and installation tosee if they are correct. and test again until it is successful.

The detector is designed for indoor use only.Every alarm requires 8 seconds minimum interval.For each setup, it is required to re-install the battery and power on againto get effect.It is required to inspect the detector periodically, and repair if any trouble.If it is in battery low (flash every 5 seconds), change the batteryimmediately to avoid alarm lose.

Note:

PDF created with pdfFactory trial version www.pdffactory.com