Korvet K SAP Jan 2008 Rev02 ENG

download Korvet K SAP Jan 2008 Rev02 ENG

of 7

Transcript of Korvet K SAP Jan 2008 Rev02 ENG

  • 8/14/2019 Korvet K SAP Jan 2008 Rev02 ENG

    1/7

    General technical review

    Name of the document

    KORVET JSC

    KSAP

    Doc. Rev / DatedPage

    OK/15082 / 06.02.091

    ESP cable sealing system

    sealaroundpenetrator (KSAP)

  • 8/14/2019 Korvet K SAP Jan 2008 Rev02 ENG

    2/7

    General technical review

    Name of the document

    KORVET JSC

    KSAP

    Doc. Rev / DatedPage

    OK/15082 / 06.02.092

    I. ESP cable sealing description

    Korvet K cable sealing system has number of advantages over conventionalproductssuchaspenetrators:

    SAP

    Simple design:

    Safety:Easyinstallation:No cable cuttingrequired:

    Cost effectiveness:

    No electricalshorting:Workover:

    KSAP does not require specially trained personnel for installationand can betestedupto 5000psi WP.

    all versions ha quick pressure testports onlyone spanner isneeded

    during installationin tubinghanger or tubinghead, thecable is left unharmed andtherefore nosplicingorepoxyworkisrequired.

    significant procurement cost advantage over wellhead

    penetrators.attubingheadbecauseofnoexcessiveconnections.

    during workover operations only the rubber sleeves needs to bereplaced.

    ve

    In Russia & Caspian Sea region Korvet has more than 20 thousand of such installations.Systemisapproved byShellspecialists.

    Working principle :

    The gland screw (1) pressurizes the rubber sleeve (4) and insulated cable (3). The ballbearing (2)assures lowfrictionoperation.

    Onnextpagesyou could see typical examplesofapplicationswithK system.SAP

    1

    2

    3

    4

    5

  • 8/14/2019 Korvet K SAP Jan 2008 Rev02 ENG

    3/7

    General technical review

    Name of the document

    KORVET JSC

    KSAP

    Doc. Rev / DatedPage

    OK/15082 / 06.02.093

    II. Wellhead design: eccentric tubing hanger

    Typical application for safe BOP removing. Replacing penetrator with K allows tosave rig time, money at completion/workover and to avoid of electric shortcuts atproducing and it removes with the usual issues of cable shorting at the producingwellhead.

    SAP

  • 8/14/2019 Korvet K SAP Jan 2008 Rev02 ENG

    4/7

    General technical review

    Name of the document

    KORVET JSC

    KSAP

    Doc. Rev / DatedPage

    OK/15082 / 06.02.094

    III. Wellhead design: suspending tubing head adapter

    Mainlyused in FormerSovietUnioncountrieswith wellheadsforESPproduction: whereBOP removal allowed without double barrier rule. K confirms the seal quicklyandeffectivelyatcompletion and aspart ofplannedmaintenance scheme.

    SAP

    Quick pressuretest port

  • 8/14/2019 Korvet K SAP Jan 2008 Rev02 ENG

    5/7

    General technical review

    Name of the document

    KORVET JSC

    KSAP

    Doc. Rev / DatedPage

    OK/15082 / 06.02.095

    IV. Wellhead design: conventional ESP wellhead

    Typical application for well conversion from natural flow to ESP. Safe BOP removing.Quickpressure test ports forcable sealing on hanger. Replacing penetrator with K

    will save rigtime, atcompletion andworkovers. It will enhance site safetyby preventingelectric joint and associated shorting at the wellhead. To be supplied together withconversional wellhead. This design is lower cost alternative to expencive conversionpenetrators.

    SAP

    Quick pressuretest port in a

    tubing hanger

  • 8/14/2019 Korvet K SAP Jan 2008 Rev02 ENG

    6/7

    General technical review

    Name of the document

    KORVET JSC

    KSAP

    Doc. Rev / DatedPage

    OK/15082 / 06.02.096

    V. Pictures from oilfield

    Energizing KSAP

    Running tubing hangertrough BOP with KSAP

    KSAP after pressuretest & removal of BOP

  • 8/14/2019 Korvet K SAP Jan 2008 Rev02 ENG

    7/7