INSTALLATION AND USER’S MANUAL KESSEL - Pumpfix ® -F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated sewage pump For sewage and greywater Control unit with SDS (Self Diagnosis System) Automatic closure during backwater Manual closure lever Simple access for maintenance Rotatable, tiltable and vertically adjustable cover (1.5 ton load class) Also available for exposed / suspended pipe Article # 28100 S/X, 28125 S/X, 28150 S/X Product Advantages Company / Telephone No. Installation of this unit should be carried out by a licensed professional servicer. Service Änderungsstand: 07/2008 HG Sachnummer: 205-106 Subject to technical amendments Pumpfix ® F for exposed pipe installation Pumpfix ® F for concrete slab installation

Transcript of KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve...

Page 1: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

INSTALLATION AND USER’S MANUAL

KESSEL- Pumpfix®-F Backwater Valve with Sewage PumpFor wastewater with or without sewage

Backwater valve with integrated sewage pump

For sewage and greywater

Control unit with SDS (Self Diagnosis System)

Automatic closure during backwater

Manual closure lever

Simple access for maintenance

Rotatable, tiltable and vertically adjustable cover

(1.5 ton load class)

Also available for exposed / suspended pipe

Article # 28100 S/X, 28125 S/X, 28150 S/X

Product Advantages

Company / Telephone No.

Installationof this unit should be carried out by a licensed professionalservicer.

Service

Änderungsstand: 07/2008 HGSachnummer: 205-106Subject to technical amendments

Pumpfix® Ffor exposed pipeinstallation

Pumpfix® Ffor concrete slab installation

Page 2: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

Table of Contents

1. Safety Instructions .......................................................................................................... page 4

2. General 2.1 Areas of application .......................................................................... page 52.2 Contents of delivery .......................................................................... page 52.3 When to install the Pumpfix® F.......................................................... page 5

3. Installation 3.1 Installation in a concrete slab / floor.................................................. page 53.2 Deep installation in a concrete slab / floor ....................................... page 63.3 Installation subject to groundwater ................................................... page 63.4 Installation in exposed / suspended pipe .......................................... page 63.5 Installation example .......................................................................... page 7

4. Electrical Connections 4.1 Wall mounting of the control unit....................................................... page 84.2 Cable connections ............................................................................ page 84.3 Installing the optical probe ................................................................ page 84.4 Audible signalling device with extension cable (optional) ................. page 94.5 Potential free contact ........................................................................ page 94.6 Shortening the cables ....................................................................... page 94.7 Cable extensions .............................................................................. page 104.8 Electrical connection plan ................................................................. page 10

5. Initializing the System .......................................................................................................... page 11

6. Operation 6.1 Principle functions............................................................................. page 126.2 Custom pump settings ...................................................................... page 136.3 Alarms / Pump Test........................................................................... page 15

2

Page 3: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

Table of Contents

3

7. Problem Notification 7.1 Notification during power use............................................................ page 167.2 Notification of power failure............................................................... page 17

8. Additional Functions 8.1 Self Diagnosis System (SDS) ........................................................... page 188.2 Battery life and replacement ............................................................. page 188.3 Battery function................................................................................. page 188.4 Signalling device with auxiliary connection (optional) ....................... page 18

9. Technical Data .......................................................................................................... page 19

10. Inspection and Maintenance 10.1 Inspection ......................................................................................... page 2010.2 Maintenance ..................................................................................... page 2010.3 Checking the pump........................................................................... page 2010.4 Checking the control unit .................................................................. page 2110.5 Malfunctions...................................................................................... page 21

11. Replacement Parts .......................................................................................................... page 22

12. Warranty .......................................................................................................... page 23

Page 4: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

1. Safety Instructions

4

Dear customer,

Before placing the KESSEL Pumpfix® F inservice, please carefully read and followthis Installation and User’s Manual. Theinformation provided in this manual isvaluable and will help provide years of safeand reliable service of the Pumpfix® Fbackwater valve.

Upon receipt of the Pumpfix® F please checkto make sure that it has been deliveredundamaged. In the case that the Pumpfix® Fhas been damaged during delivery, pleasefollow the warranty instructions in Chapter12.

ImportantAlways unplug the Pumpfix® F beforeinspection or maintenance!

Use caution during installation, inspection,maintenance, use and repair of this product.

The Pumpfix® F is not to be installed in anarea which is or could be subject to explosion.

The Pumpfix® F uses electricity and movingmechanical parts. Not following theInstallation and Userʼs Manual could resultin bodily injury or a fatal accident.

If at any time the electrical cables or anyother part of the Pumpfix® F is damaged, thebackwater valve should in no way be placedinto operation.

Do not inspect or maintain the Pumpfix® Fduring times of backwater or during times ofrisk of backwater (heavy rain / flooding).

The internal backwater flap and the manualclosure lever must always have full range ofmotion.

KESSEL recommends that a maintenancecontract be signed with a licensedprofessional servicer.

Page 5: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

2. General

5

2.1 Areas of applicationThe Pumpfix® F is designed to be installedin a downward sloped, vented, continousrun drainage pipe. In this application thePumpfix® F will provide through drainageduring normal conditions, protection againstbackwater during times of backwater andthe drainage of connected plumbing fixtureseven during times of backwater. When afixture plumbed into the Pumpfix® F isdrained during times of backwater, thePumpfix® F will intake the wastewater,macerate any solids with its cutting pumpand pump out the waste against thepressure of the backwater.

Important:A requirement for trouble free operation isthat the Pumpfix® F is installed in a pipe withproper slope and ventilation.2.2 Contents of deliveryThe Pumpfix® F package includes the valveitself (with pump and backwater flap) and acontrol unit. Included with the splash proofcontrol unit (230V - 50 Hz) is the opticalprobe and Installation and Userʼs Manual.

2.3 When to install the Pumpfix® FIf the Pumpfix® F is being installed duringthe construction phase of a building only the

body of the valve with cover and pumpshould be installed (the optical probe andcontrol unit should not be connnected)(Chapter 3). During this time make sure tostore the electrical components in a cleanand dry place. When the heavy constructionphase of the building is complete the opticalprobe should be installed in the cover of thevalve, the control unit mounted on a nearbywall and all necessary electricalconnections made. This will help preventdamage to the mechanical and electricalequipment of the Pumpfix® F during theconstruction phase.

3. Installation

Please take caution that:The drainage pipe to which the Pumpfix® Fis connected is laid at the slope required bythe local governing code and that the inletpipe to the Pumpfix® F is properly vented. Itis recommended that all plumbing fixtures

above the backwater level be connecteddownstream of the Pumpfix® F since thesefixtures do not need to be protected againstbackwater. Only fixtures below the backwaterlevel should be plumbed through thePumpfix® F.

3.1 Installation in a concrete slab / floorArticle # 28100 S or X, 28125 S or X and28150 S or X)

Page 6: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

6

3. Installation

The body of the Pumpfix® F should beinstalled level as shown in Illustration 1. Theelectrical cables connecting the Pumpfix® Fto the control unit should be run through aDN 50 pipe as shown in Illustrations 2 and 5.Grease and install the included rubber gas-ket between the Pumpfix® F body and theaccess chamber as shown in Illustration 3.As seen in Illustration 4, the access chamberof the Pumpfix® F body is completely adju-stable. This access chamber can be raisedor lowered to meet floor heights, tilted late-rally to meet grades in the floor and rotatedto match floor patterns.

3.2 Deep installation in a concreteslab / floor

For deep installation depths use theextension section (Product Number 83070).If installing an extension section make sureto grease the rubber gasket. If more thanone extension section is needed, make surenot to install the Pumpfix® F so deep that ac-cess to the valve for inspection and mainte-nance is hindered.

3.3 Installation subject to groundwaterThere are certain circumstances where theupward force of groundwater can penetratethrough slab installed fixtures and causemoisture problems. The KESSEL Pumpfix®

F provides protection against the upwardforce of groundwater by including the waterbarrier (Product Number 83019 (Rubberbarrier) and Number 83018 (Flange)).Thisrubber barrier is simply placed between thebody of the Pumpfix® F and the flange whichis then bolted tight with the included boltsas shown in Illustration 6.

3.4 Installation in an exposed /suspended pipe

The Pumpfix® F backwater valve, designedto be installed in an exposed / suspendedpipe, comes equipped with a see-thru,easily removable protective cover.

The motor cable and the optical probe cableshould be run through their two respectiveholes in the body of the valve.

Illus. 1

Illus. 3

Illus. 5

Illus. 2

Illus. 4

Page 7: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

3. Installation

7

ATTENTION:Make sure that no cables or otherobjects impair the movement of themanual closure lever or interfere with theoperation, inspection or maintenance ofthe valve.

Illus. 6

Flange

Illus. 7 � �

� � ��

3.5 Installation Example

� Pumpfix® F� Flange� Pump

� Manual closure lever� Control unit

� Cover (Load capacity- 1.5 tons)

� Water barrier (rubber)

Cellar drain, washingmachines, sinks,bathtubs, toilets

InletOutlet

rubber barrier

Page 8: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

8

4. Electrical connections

4.1 Wall mounting of the control unitAs always, make sure the control unit isdis connected from the power supply beforeopening the cover.Unscrew the four screws located in eachcorner of the front of the control unit andopen the cover. In each corner of the insideof the control unit will be four holes formounting the control unit to the wall.Included with the control unit are 4 mountingscrews, 4 plastic wall plugs and a drillingtemplate which is printed on the packagingbox of the control unit.

4.2 Cable connectionsAn electrical connection plan is located onthe inside of the control unit cover.On the bottom of the control unit (as seen inIllustration 9), remove the hand bolt (thirdfrom left) and pierce the cable inlet seal (thisis for the pump cable) and also the fourthfrom the left cable seal (this is for the opti-cal probe cable).Insert the cables for the pump and the opti-cal probe through their newly pierced inlets

and into the control unit. Secure the cablesto the control unit box by tightening the pla-stic hand bolts (as seen in Illustration 10).Now connect the wires of the pump and theoptical probe to their respective terminals asshown in Illustration 14. To connect thewires, firmly insert a small screwdriver intothe upper opening of each jack and push upas shown in Illustration 11. This opens theterminal. Insert the lead of the correspondingwire into the lower opening of the jack andrelease the screwdriver. The wire is nowconnected. To connect the pump, there arefour wires to be connected to a set of jacksinside the control unit. The green and yellowstriped wire and the three black wires label-

led ʻ1ʼ, ʻ2ʼ and ʻ3ʼ should be connected totheir respective jacks on the jack set with 4connection ports labelled ʻPUMPEʼ (thegreen and yellow striped wire to be connec-ted to the green jack). To connect the opti-cal probe, there are three colored wires la-belled ʻ1ʼ (blue), ʻ2ʼ (white) and ʻ3ʼ (grey)which should be connected to their respec-tive jacks on the jack set with 3 connectionports (blue, white, grey) labelled ̒ SONDE1ʼ.

4.3 Installing the optical probeTo install the optical probe into the Pumpfix®

F simply remove the small purple plug fromthe cover of the Pumpfix® F by unscrewingthe two screws. Now insert the probe and

Illus. 9 Illus. 10

Page 9: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

9

4. Electrical connectionstighten with the same two screws as seen inIllus. 12. (the optical probe is designed sothat it can only be installed the proper way).

4.4 Audible signalling device withextension cable

An optional audible external signalling devi-ce (Product Number 20162) can be connec-ted if it is required to transmit the audiblewarning signal to other areas of the building.control system.

4.5 Potential free contactAn optional Potential free contact (Article #80072) can be installed to allow the Pump-fix® F to be connected to a warning beacon,audible alarm or a buildingʼs central controlsystem. The additional circuit board is plug-ged into the mother board inside the controlunit and fastened with the 4 provided scr-ews (as seen in Illustration 13).

4.6 Shortening the cablesThe cables from the control unit to thePumpfix® F can be shortened if necessary.However, please insure that there is alwaysenough cable so that the Pumpfix® F motorand cover can be removed for inspectionand maintenance.

Illus. 12

Illus. 11

1. 2.

3.

Illus. 13

Page 10: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

10

4.7 Cable extensionsThe motor cable and the optical probe cablefor the Pumpfix® F are delivered with alength of 5 meters. If requested the unit canbe supplied with 15 meter cables instead ofthe standard 5 meter cable length. If requi-red, the cables may be extended there is noneed to increase the cross-sectional area ofthe 3 wires - they can remain at the original0.75 square millimeter. In order to preven in-terferences, the probe and the motor shouldbe extended with separator cables. Maxi-mum length of either the motor or the opti-cal probe cable should be 30 meters.

Note:VDE 0100, VDE 01107 and IEC guideli-nes must be followed in Germany andareas under IEC jurisdiction. In otherareas it is important to follow regulationsissued by local power companies.

The Pumpfix® F and control unit must not beinstalled in areas where there is or could bea risk of explosion.

4.7 Electrical connection plan

4. Electrical connections

Illus. 14

Page 11: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

11

5. Initialization

While the control unit is unplugged connectthe two supplied 9-volt batteries which are al-ready located inside the control unit. Closethe cover of the control unit andtighten the four screws. Plug in the controlunit to a suitable power supply. The controlunit will perform a basic systems check.During initialization the system checks thebatteries, pump, optical probe and pumpconnections to confirm that they areproperly connected and in working order.Important:Never place hands or objects near thecutting blades of the Pumpfix® F.

If the entire system has been installedcorrectly the green ̒ POWERʼ LED will turn onand remain on. The Pumpfix® F is now readyfor operation.When the system is ready for operation,make sure that the red manual closure leverfor the backwater flap is in the ʻFLAP OPEN(FREE HANGING)ʼ (vertical) position. If it isnot, open it with the red manual closure lever.

ALARM

NIVEAU

PUMPE

PRÜFEN

POWER

Page 12: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

12

6. Operation6.1 Principle Functions

1. Normal operation 2. Backwater operation3. Wastewater disposal during

backwater

As backwater occurs, the free hanging flapis forced closed due to the pressure of thebackwater and provides a complete sealagainst the back-up of wastewater into all ofthe Pumpfix® F protected areas.

During times of backwater the Pumpfix® F pro-tects a building against the back-up of waste-water while at the same time disposing of itswaste. This is possible because of an opticalsensor and integrated sewage pump locatedwithin the Pumpfix® F. As a buildingʼs plumbingfixtures are drained during times of backwaterthe wastewater level rises inside the piping sy-stem and the Pumpfix® F. This is sensed by theoptical probe which activates the cutting pump.The pump intakes the wastewater, maceratesthe solids and pumps against the pressure ofthe backwater. The integrated free hanging flapprevents the grey water or sewage from flowingback into the building.

During normal conditions the Pumpfix® Ffunctions as a standard backwater valve asshown in the ʻNormal Operationʼ illustrationabove. The force of the free flowing waste-water pushes the free hanging flap open andallows the waste water to pass unhinderedto a public sewer line or a private sewagesystem.

Cellar drain, washing machines,sinks, bathtubs, toilets

Cellar drain, washing machines,sinks, bathtubs, toilets

Cellar drain, washing machines,sinks, bathtubs, toilets

Page 13: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

13

6. Operation

Pumpingtimes (sec.) 5 10 15 20 25 30 35blinking LEDs 1 1+2 2 2+3 3 3+4 4

6.2 Custom Pump SettingsThe Pumpfix® F is delivered pre program-med so that it can be installed and usedeffectively without setting any of the custompump settings. The pre programmed settingwill handle all drainage and backwaterscenarios. However, customized pumpsettings can be programmed if adjusting thesettings of the Pumpfix® F can increaseperformance and longevity.

Programming the Pumpfix® FFor programming the Pumpfix® F use theLED numbers as identified belowLED 1 : ʻPOWERʼ LEDLED 2 : ʻALARMʼ LEDLED 3 : ʻPROBE SUBMERGEDʼ LEDLED 4 : ʻPUMPING / TEST PUMPʼ LED

Setting the pumping times.The Pumpfix® F can be programmed toadjust how long the pump runs. This is doneby keeping both the ʻALARMʼ and ʻPUM-PING / TEST PUMPʼ buttons pressed for afew seconds until the continuous alarm tonesounds. After releasing the ʻALARMʼ andʻPUMPING / TEST PUMPʼ buttons thecurrent pump time setting can be determinedby the blinking LEDs (please see tablebelow). The length of pumping time can nowbe programmed. To change the pumpingtimes press the ʻALARMʼ button. Each timethe ʻALARMʼ button is pressed, 5 secondswill be added to the pumping time. Thenewly enterred times can be determined byone or two blinking LEDs and checking withthe table below. When the desired pumpingtime has been enterred press the ʻPUM-PING / TEST PUMPʼ button to save the newsetting. The new pumping time changes willbe confirmed by a two toned audible signal.

If within 20 seconds the changes are notsaved by pressing the ʻPUMPING / TESTPUMP ̓button, the Pumpfix® F will automaticallysave the previous pumping time (this will beconfirmed by a single tone audible signal).The Pumpfix® F is delivered pre-program-med with a pumping time of 10 seconds.

Page 14: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

14

6. OperationSetting the ʻPump start delayʼ times.The Pumpfix® F can be programmed todelay starting the pump after the optical sen-sor has sensed wastewater. The advantageof this is that the wastewater will have achance to build up in the pipe so that thePumpfix® F can pump out the entire volumewith one activation rather than turning onand off several times. To change the ʻPumpstart delayʼ times keep both the ʻALARMʼand ̒PUMPING / TEST PUMPʼ buttons pres-sed for a few seconds until the continuousaudible alarm sounds. Release the ̒ALARMand ʻPUMPING / TEST PUMPʼ buttons.Now again press both the ʻALARMʼ andʻPUMPING / TEST PUMPʼ buttons for a fewseconds until the continous audible alarmsounds again and the ̒ POWERʼ and ̒ ALAR-Mʼ LEDs light. After releasing the ʻALARMʼand ʻPUMPING / TEST PUMPʼbuttons the current pump start delay timesetting can be determined by the blinkingLEDs (please see table below). To change

the pump start delay times press the ̒ ALAR-Mʼ button. Each time the ʻALARMʼbutton is pressed, additional time will beadded to the pump start delay time. Theenterred times can be determined by lookingat the blinking LEDs and checking with thetable below. When the desired pump startdelay time has been enterred press theʻPUMPING / TEST PUMPʼ button to save thenew setting. The new ʻPump start delayʼtimes will be confirmed by a two tonedaudible signal. If within 20 seconds thechanges are not saved by pressing theʻPUMPING / TEST PUMPʼ button, thePumpfix® F will automatically save theprevious ʻPump start delayʼ (this will beconfirmed by a single tone audible signal).The Pumpfix® F is delivered pre-programmedwith a pump start delay time of 1 second.

Setting to either ʻFinish Controlledʼ or ʻStartControlledʼ modes.

The Pumpfix® F can be programmed tooperate in either ʻFinish Controlledʼ or ʻStartControlledʼ modes. In the Finish Controlledpump setting mode, the optical probesenses the build-up of wastewater in thedrainage pipe and activates the Pumpfix® Fwhich will begin pumping after the program-med delay start time has elapsed. In thismode the pump will continue to run for theprogrammed period of time after thewastewater level has fallen below the opticalsensor level. In the Start Controlled pumpsetting mode, the optical probe senses thebuild-up of wastewater in the drainage pipeand activates the Pumpfix® F which willbegin pumping after the programmed delaystart time has elapsed. In this mode thepump will run for the programmed period oftime and then shut off. If there is still waste-water above the sensor level the pump will

Pump StartDelay (sec.) 0,5 1,0 1,5 2,0 3,0 4,0 5,0blinking LEDs 1 1+2 2 2+3 3 3+4 4

Page 15: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

15

6. Operationagain turn on after the pump start delay timehas elapsed.

The Pumpfix® F can be programmed to beeither in ̒ Finish Controlledʼ or ̒ Start Controlle-dʼ mode. To change to either ̒ Finished Con-trolledʼ or ̒ Start Controlledʼ mode keep boththe ̒ ALARMʼ and ̒ PUMPING / TEST PUMPʼbuttons pressed for a few seconds until thecontinuous audible alarm sounds. Releasethe ̒ ALARM and ̒ PUMPING / TEST PUMPʼbuttons. Again press both the ̒ ALARMʼ andʻPUMPING / TEST PUMPʼ buttons for a fewseconds until the continous audible alarmsounds and the ʻPOWERʼ and ʻALARMʼLEDs light. Again release the ʻALARMʻ andʻPUMPING / TEST PUMPʼ buttons. For thethird time press both the ʻALARMʼ andʻPUMPING / TEST PUMPʼ buttons depres-sed for a few seconds. The control unit willconfirm that it is in ʻFinish Controlledʼ andʻStart Controlledʼ setting mode by a conti-nuous audible signal along with the ʻPO-WERʼ, ʻALARMʼ, and ʻPROBE SUBMER-GEDʼ LEDs lighting. After

releasing the ʻALARMʼ and ʻPUMPING /TEST PUMPʼ buttons the current Controlsetting can be determined by the blinkingLEDs (please see table below). To changethe Control setting press the ʻALARMʼbutton. The enterred Control setting can bedetermined by looking at the blinking LEDsand checking with the table below. Whenthe desired Control setting has been enter-red, press the ʻPUMPING / TEST PUMPʼbutton to save the new setting. The newControl setting will be confirmed by a twotoned audible signal. If within 20 secondsthe changes are not saved by pressing theʻPUMPING / TEST PUMPʼ button, thePumpfix® F will automatically save theprevious control setting (this will be confirmedby a single tone audible signal). ThePumpfix® F is delivered pre-programmed inthe ʻFinish Controlledʼ mode.

6.3 Alarms / Pump Test

ALARM - The “Alarm” button located on thePumpfix® F control unit can be used to can-cel the audible alarm. The LED alarm lightwill remain lit after the audible alarm hasbeen cancelled to notify the user of the cur-rent problem / situation. If desired, the“Alarm” button can be pressed again whichwill re-activate the audible alarm.

PUMP TEST - The motor of the Pumpfix® Fcan be manually started / tested by pressingthe “Pump” Test button. This can serve as aquick and easy test to assure that the motoris in working condition. Do not keep the“Pump Test” button depressed for morethan a few seconds.

Mode Finish Startcontrolled controlled

blinking LEDs 1 2

Page 16: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

16

7. Problem notification

Notification Problem Solution Tips

Battery is missing or defective.

This notification during initializationcould mean the pump is notconnected, polarity is improperlyconnected or the pump is damaged.This notification during operationmeans the pump is not functioningproperly.

Connect or replace the battery.

Disconnect from power, disconnect bat-teries and check to make sure thecables for the pump are properlyconnected. If damaged, replace pump.Reconnect batteries, close the coverand tighten the cover screws of thecontrol unit and then plug in control unit.

With unconnected or defec-tive batteries, the Pumpfix®

F will not place itself into ope-rational status after initializa-tion.

The probe tests itself everytwo seconds and will notifythe user if any attemptedrepairs were successful.

The SDS System willmonitor the pump anddisplay any problems.

All 4 LEDs blink si-multaneously and au-dible alarm sounds

The top two LEDs (ʻPO-WERʼ & ʻALARMʼ) andbottom two LEDs(ʻPROBE SUBMERGEDʼ& ʻPUMPING / TESTPUMPʼ) blink alternatinglyand audible alarm sounds

This notification during initializationcould mean the optical probe is notconnected, polarity is improperlyconnected or the probe is damaged.This notification during operationmeans the probe is not functioningproperly.

During initialization and use the KESSEL control unit notifies the user of problems which can aid in finding easy solutions.

7.1 Notification during power use:

Disconnect from power, disconnect bat-teries and check to make sure thecables for the probe are properly connected.If damaged, replace probe. Reconnectbatteries, close the cover and tighten thecover screws of the control unit and thenplug in control unit.

ʻPOWERʼ LED andʻALARMʼ LED blinkalternatingly and au-dible alarm sounds

Page 17: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

17

7. Problem notification7.2 Notification of power failure:

Notification Problem Solution Tips

The Pumpfix® F is not receivingpower (has been disconnected or apower failure has occurred).

Reconnect to a suitable power supplyor wait for power failure to end.

The pump of the Pumpfix®

F will not operate withoutfull outlet power! Theaudible alarm will sound for8 hours after the power hasfailed and then thePumpfix® F will go intoʻSleep Modeʼ where all theLEDs will go out.

The Pumpfix® F has not receivedpower for over 8 hours.

Reconnect the Pumpfix® F toa functioning power source.

During this notification, thePumpfix® F is in ʻSleepModeʼ.

The ʻALARMʼ LEDblinks every twoseconds and alarmsounds.

All LEDs are out.

Page 18: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

18

8. Additional functions8.1 Self Diagnosis System (SDS)As part of the SDS Control unit, thePumpfix® F automatically tests its pumpingsystem once per month. As part of this selftest, the pump will run for two seconds. If thePumpfix® F detects any problems with itsoperation during this monthly test, it willdisplay the problem on the control unit asdescribed in Chapter 7. This is an importantreason that the Pumpfix® F always beunplugged before maintaining or inspectingthe unit. With the Pumpfix® F unpluggedthere is no risk of unintended activation ofthe pump.

8.2 Battery life and replacementWhile the Pumpfix® F is connected to asuitable power supply, the unit continuous-ly checks the condition of the two batteries.If at time of initialization the batteries holdunder 12.5 Volts total power, the Pumpfix®

F will not initialize itself. In this case, unplugthe Pumpfix® F control unit from its powersource, check and replace the batteries ifnecessary and then reconnect the control

unit to its power source. The estimated lifeof new batteries is four years. Batteriescertified for use with the KESSEL Pumpfix®

F are Duracell 9 Volt Type MN 1604/6LR61(Requirement - 2). If discarding batteries,please do so properly.

8.3 Battery functionThe purpose of the batteries is to notify theuser of a power failure by LED and audiblealarm notification. Although during a powerfailure the Pumpfix® F will continue to provi-de protection against backwater due to itsfree hanging backwater flap, the pump ofthe Pumpfix® F will not operate.

Please note: The auxiliary device iscertified for up to 42 Volts / 0.5 A.

Page 19: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

19

10. Technical Data

Fuse 10 Amp fusePower 230 V AC / 50 HzPower use in stand-by mode 17 mATemperature limits 0°C + 40°CSplash Protection IP 54 (control unit)Protection Class 1Power supply 230 V AC, 16 A, cos w = 1Potential free contact power supply 42 V DC / 0,5 A

Control Unit

Pump

Power usage 1 kilowattCurrent 4.9 AmpOperation type S 30-30 %Splash Protection IP 68 (3 m depth / 24 hours)Capacity against 4.3 psi (0.3 bar) 35.2 gallons / minute (133 liters/minute)Motor cable 4x1 mm2Optical probe cable 3x0,75 mm2Performance at 0.3 bar Q 10 m3/h = 2,2 l/s

Page 20: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

20

10. Inspection and Maintenance

10.1 InspectionThe Pumpfix® F should be inspected monthlyby the owner or a professional servicer toinsure that it is in proper operating condition.Please follow the following guidelines:

• Close the red manual hand lever (pushfrom vertical to horizontal position).

• Drain a fixture which is connected to thePumpfix® F (flush a toilet, let a faucet run).

• Wait for the ʻPROBE SUBMERGEDʼ andʻPUMPING / TEST PUMPʼ LEDs to lightand for the pump to activate.

• Discontinue draining the fixture into thePumpfix® F.

• Wait for the ʻPROBE SUBMERGEDʼ andʻPUMPING / TEST PUMPʼ to turn off andthe pump to stop running.

• Re-open the red manual hand lever (returnit to the vertical position).

10.2 MaintenanceCaution! Be sure to unplug the Pumpfix®

F before doing maintenance work! Followall safety instructions! The followinginspection and maintenance work must

only be completed by a licensed professional servicer.

Important:The bolts on the Pumpfix® F cover shouldbe tightened in a crosswise pattern to atorque of 6 lbf-ft (8 Nm).

• Visual inspection of the entire unit.• Cleaning of the entire unit including the

pump.• Check the entire unit and pump for

damage or wear.• Check the pump for freedom of movement,

wear and tear and build up.• Check the pipe connections for wear and

tear.• Check if the lens of the optical probe is dirty

and clean with a clean soft cloth ortissue if necessary.

• Check all seals for signs of wear.

The above checks are also recommendedafter extended unuse or storage.

10.3 Checking the pumpThe pump should be checked regularly. Inthe case of unusual noises during operation,decrease in pump performance, or vibrationof the unit and piping system make sure thata complete inspection of the pump, the pumphousing and the impeller are completed by alicensed professional servicer.

Page 21: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

21

10. Inspection and Maintenance

10.4 Checking the control unit The batteries should be checked yearly andreplaced if necessary. If replacing thebatteries make sure to install recommen-ded batteries and dispose of the old batte-ries properly.

Repairs of the control unit shall only be doneby a licensed professional servicer.

10.5 MalfunctionsIn the case of an undiagnosable malfunctionof the Pumpfix® F, please contact yourdistributor or supplier.

Page 22: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

22

11. Replacement Parts11.1 Detailed drawing 11.2 Replacement parts list

Order Number

11. Cover with motor DN 100/125 205-046

12. Cover with motor DN 150 205-045

13. Pump housing upper section for DN 100, DN 125 models 205-032

14. Pump housing upper section for 6 DN 150 models 205-016

15. Pump housing lower section DN 100/125/150

16. Cutting knife

17. Cutting plate

18. Impeller

19. Flap assembly (3 parts) 205-034

10. Control unit 28070

11. Optical probe DN 100 80086

12. Optical probe DN 125 / 150 80085

13. Potential Free Contact 80072

}205-101(DN 100/125)205-118(DN 150)nur im Setaustauschbar

Page 23: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

23

12. Warranty1. In the case that a KESSEL product isdefective, KESSEL has the option of re-pairing or replacing the product. If the pro-duct remains defective after the secondattempt to repair or replace the product orit is economically unfeasible to repair orreplace the product, the customer the hasthe right to cancel the order / contract orreduce payment accordingly. KESSEL must be notified immediately inwriting of defects in a product. In the casethat the defect is not visible or difficult todetect, KESSEL must be notified imme-diately in writing of the defects as soon asit is discovered. If the product is repaired

or replaced, the newly repaired or repla-ced product shall receive a new warrantyidentical to that which the original (defec-tive) product was granted. The term de-fective product refers only to the productor part needing repair or replacement andnot neccessarily to the entire product orunit. KESSEL products are warrantied fora period of 24 months. This warranty pe-riod begins on the day the product is ship-ped from KESSEL to its customer. Thewarranty only applies to newly manufac-tured products. Additional information canbe found in section 377 and 378 of theHGB.

2. Wear and tear on a product will not beconsidered a defect. Problems with pro-ducts resulting from improper installation,handling or maintenance will also not beconsidered a defect.

01.01.2002

Page 24: KESSEL-Pumpfix -F Backwater Valve with Sewage Pump For ... · KESSEL-Pumpfix®-F Backwater Valve with Sewage Pump For wastewater with or without sewage Backwater valve with integrated

Solutions from a single source

E v e r y t h i n g f o r D r a i n a g e

Backwater valves and cleanouts

Polymer and cast iron drains

Volatile liquid traps

Lifting stations, pumps, warningand control units

Rainwater management systems

Grease, starch and oil / fuelseparators

Inspection chambers

Custom projects for industrialapplications

Polymer pipe fittings

Stainless steel drains andchannels