Keeping Hot Chips Cool
Thermal Management for Green Computing
Yang Ge Professor Qinru Qiu
![Page 2: Keeping Hot Chips Cool](https://reader036.fdocuments.in/reader036/viewer/2022062501/5681633e550346895dd3cdd7/html5/thumbnails/2.jpg)
utline• Background– Need for green computing– Adverse effects of high temperature– Thermal management techniques
• Ongoing project– Power and thermal management for single chip
cloud computer (SCC)
![Page 3: Keeping Hot Chips Cool](https://reader036.fdocuments.in/reader036/viewer/2022062501/5681633e550346895dd3cdd7/html5/thumbnails/3.jpg)
The need for green computing• Computers consume 3%
of US energy use– Saving 1% of energy of
data center is more than saving a power plant
• Each computer generates 1 ton of CO2 every year– Equivalent to the CO2
emission of a car driving a round trip between New York and Los Angeles
![Page 4: Keeping Hot Chips Cool](https://reader036.fdocuments.in/reader036/viewer/2022062501/5681633e550346895dd3cdd7/html5/thumbnails/4.jpg)
Power and Cost for Cooling Systems• The energy dissipation for
cooling system is high– Cooling fan power can reach
up to 51% of the overall server power budget
• The cooling cost is expensive in large data centers– The total cooling costs for
large data centers can run into tens of millions of dollars
Fans
CPU
Mem
OtherFans 51%
Mem 20%
CPU 24%
Other 6%
IBM P670 Server power breakdown
![Page 5: Keeping Hot Chips Cool](https://reader036.fdocuments.in/reader036/viewer/2022062501/5681633e550346895dd3cdd7/html5/thumbnails/5.jpg)
Adverse effects of high temperature to VLSI Chips
• Affects the system reliability and causes permanent device failure
• Doubles leakage power consumption every 9oC increase
• Requires to increase fan speed which could reduce fan life time
![Page 6: Keeping Hot Chips Cool](https://reader036.fdocuments.in/reader036/viewer/2022062501/5681633e550346895dd3cdd7/html5/thumbnails/6.jpg)
Thermal Management Techniques
Offline Techniques
Online Techniques
Temperature aware scheduling
Dynamic voltage frequency scaling
Temperature aware task migration
![Page 7: Keeping Hot Chips Cool](https://reader036.fdocuments.in/reader036/viewer/2022062501/5681633e550346895dd3cdd7/html5/thumbnails/7.jpg)
Ongoing Project• Power and thermal management for
single chip cloud computer (SCC)
![Page 8: Keeping Hot Chips Cool](https://reader036.fdocuments.in/reader036/viewer/2022062501/5681633e550346895dd3cdd7/html5/thumbnails/8.jpg)
• 24 tiles arranged in 6X4 arrays
• 2 CPUs on each tile
• A router associated with each tile
• 4 memory controllers go to on board memory
Overview of SCC Architecture
![Page 9: Keeping Hot Chips Cool](https://reader036.fdocuments.in/reader036/viewer/2022062501/5681633e550346895dd3cdd7/html5/thumbnails/9.jpg)
• SCC and MCPC communicates over PCIe bus
• MCPC runs Ubuntu 10.04 x64 and SW from Intel
• Load Linux image on each core
• read and modify SCC registers
• Load programs on the SCC cores.
Management Console PC (MCPC)
![Page 10: Keeping Hot Chips Cool](https://reader036.fdocuments.in/reader036/viewer/2022062501/5681633e550346895dd3cdd7/html5/thumbnails/10.jpg)
• 6 voltage domains• 24 Frequency
domains, one for each tile
• 2 temperature sensors on each tile
• Voltage and frequency can be changed separately on each domain
Power and Thermal Management
![Page 11: Keeping Hot Chips Cool](https://reader036.fdocuments.in/reader036/viewer/2022062501/5681633e550346895dd3cdd7/html5/thumbnails/11.jpg)
hank y u