KAtalog - User Manual Search Engine · M Series S Series P Series Multi System Line Up Mitsubishi...

48
New publication effective Aug. 2006 Specifications subuject to change without notice L-179-5-C6975-D SI 0608 HEAD OFFICE: TOKYO BLDG.,2-7-3, MARUNOUCHI,CHIYODA-KU, TOKYO 100-8310, JAPAN http://Global.MitsubishiElectric.com/ 2006

Transcript of KAtalog - User Manual Search Engine · M Series S Series P Series Multi System Line Up Mitsubishi...

  • New publication effective Aug. 2006Specifications subuject to change without noticeL-179-5-C6975-D SI 0608

    HEAD OFFICE: TOKYO BLDG.,2-7-3, MARUNOUCHI,CHIYODA-KU, TOKYO 100-8310, JAPANhttp://Global.MitsubishiElectric.com/

    2006

  • M Series

    S Series

    P Series

    Multi System

    Line Up

    Mitsubishi Electric's Main Technology

    High End Models

    Icons

    3-6

    7-14

    15-24

    25

    26-39

    40-42

    43-73

    74-90

    C O N T E N T S

    Mitsubishi Electric,s Long history proves excellence in air conditioning with the leading-edge technology.With 50 years experience in developing air conditioner, Mitsubishi Electric's cost effective ,

    energy conscious systems are expertly designed to provide you with constant ,

    comfortable living and working environments.

  • P75

    P77

    P77

    P77

    P77

    P77

    P87

    P87

    P87

    P87

    P87

    P87

    Wall Mounted Ceiling SuspendedFloor Standing Ceiling ConcealedCassette

    ■INVERTER Models ●Heat Pump type

    ■FIXED-SPEED Models ●Cooling Only type

    MXZ-8A140VA

    Multi Series

    up to 8indoor units

    14.0kW

    MXZ-4A80VA

    up to 4indoor units

    8.0kW

    MXZ-4A71VA

    up to 4indoor units

    7.1kW

    MXZ-3A54VA

    up to 3indoor units

    5.4kW

    MXZ-2A52VA

    up to 2indoor units

    5.2kW

    MXZ-2A40VA

    up to 2indoor units

    4.0kW

    MUX-4A73VB

    up to 4indoor units

    7.3kW

    MUX-3A63VB

    up to 3indoor units

    6.3kW

    MUX-3A60VB

    up to 3indoor units

    6.0kW

    MUX-2A70VB

    up to 2indoor units

    7.0kW

    MUX-2A59VB

    up to 2indoor units

    5.9kW

    MUX-2A28VB

    up to 2indoor units

    2.8kW

    MSZ-FA25/35MSZ-GA22/25/35

    MSZ-GB50, GA60/71

    MSZ-FA25/35MSZ-GA22/25/35

    MSZ-GB50, GA60/71

    MSZ-FA25/35MSZ-GA22/25/35MSZ-GB50, GA60

    MSZ-FA25/35MSZ-GA22/25/35

    MSZ-GB50

    MSZ-FA25/35MSZ-GA22/25/35

    MSZ-FA25/35MSZ-GA22/25/35

    MSC-GA25/35

    MSC-GA20/35

    MSC-GA25

    MSC-GA35

    MSC-GA20/35

    MSC-GA20

    MFZ-KA25/35/50

    MFZ-KA25/35/50

    MFZ-KA25/35/50

    MFZ-KA25/35/50

    MFZ-KA25/35

    MFZ-KA25/35

    SLZ-KA25/35/50PLA-RP35/50/60/71

    SLZ-KA25/35/50PLA-RP50/60/71

    SLZ-KA25/35/50PLA-RP50/60

    SLZ-KA25/35/50PLA-RP50

    SLZ-KA25/35

    SLZ-KA25/35

    SEZ-KC25SEZ-KA35/50/60/71PEAD-RP50/60/71EA

    PEAD-RP60/71GA

    SEZ-KC25SEZ-KA35/50/60

    PEAD-RP50EAPEAD-RP60/71GA

    SEZ-KC25SEZ-KA35/50/60

    PEAD-RP50EA

    SEZ-KC25SEZ-KA35/50PEAD-RP50EA

    SEZ-KC25SEZ-KA35

    SEZ-KC25SEZ-KA35

    PCA-RP50/60/71

    PCA-RP50/60

    PCA-RP50

    4

    Line-up

    ■INVERTER Models ●Heat Pump type

    ■FIXED-SPEED Models

    Wall Mounted

    CompactFloor

    MSZ-FA series

    MSZ-GA/GB series

    MSZ-HA series

    MFZ-KA series

    2.0kW 2.2kW 2.5kW 3.5kW 5.0kW

    New Design

    6.0kW 7.1kW 8.0kW page

    P27

    P28

    P30

    P37

    Model Name

    2.0kW 2.2kW 2.5kW 3.5kW 5.0kW 6.0kW 7.1kW 8.0kW pageModel Name

    Wall Mounted

    Two-way Floor / Ceiling

    MS(H)-GA series

    MSH-CB series

    P32

    MCF(H)-GA series

    P34

    P38

    P39

    ■INVERTER Models ●Heat Pump type2.0kW 2.2kW 2.5kW 3.5kW 5.0kW 6.0kW 7.1kW 8.0kW pageModel Name

    M series

    S series

    *

    H

    H

    H

    *

    MSZ-CB series

    P31

    2x2Cassette

    SLZ-KA series

    P41

    P36

    H

    H

    H

    HeatPump

    CoolingOnly

    HeatPump

    CoolingOnly

    HeatPump

    CompactCeilingConcealed

    SEZ-KC series

    SEZ-KA series

    P42

    P42

    3

    H:Outdoor unit with anti-freeze heater is available. *Indoor unit only

  • 6

    ■FIXED-SPEED Models

    4 way Cassette

    Ceiling Concealed

    Wall mounted

    Ceiling Suspended

    Floor Standing PS(H) series

    PC(H)-HA series

    for Professional Kitchen

    PC(H)-GA series

    PK(H)-FAL series

    PEH series

    R407C R407C

    PE(H)D-GA series

    PE(H)D-EA series

    PL(H) series

    3HP 4HP 5HP 6HP 8HP 10HP

    7.1kW 10.0kW 12.5kW 14.0kW 20.0kW 25.0kWpage

    P59

    P60

    P61

    P62

    P63

    P64

    P73

    P65

    P66

    P67

    P68

    P69

    P70

    P71

    P72

    Model Name

    P series

    HeatPump

    CoolingOnly

    HeatPump

    CoolingOnly

    HeatPump

    CoolingOnly

    HeatPump

    HeatPump

    CoolingOnly

    HeatPump

    CoolingOnly

    HeatPump

    CoolingOnly

    HeatPump

    CoolingOnly

    *Indoor unit with a booster heater is also available.

    * * * *

    * * * *

    * *

    * * * *

    * * * *

    Line-up

    5

    ■POWER INVERTER Models

    4 way Cassette

    Ceiling Concealed

    Ceiling Suspend

    Floor Standing

    3.5kW

    1.6HP 2HP 2.5HP 3HP 4HP 5HP 6HP 8HP 10HP

    5.0kW 6.0kW 7.1kW 10.0kW* 12.5kW* 14.0kW* 20.0kW** 25.0kW**page

    P44

    P45

    P46

    P47

    P48

    P48

    P49

    P50

    P51

    Model Name

    P series

    PLZ-RP series

    PEDZ-RP EA series

    PEDZ-RP GA series

    PEZ-RP series

    Wall mounted PKZ-RP GAL series

    PKZ-RP FAL series

    PCZ-RP GA series

    PCZ-RP HA seriesforProfessionalKitchen

    PSZ-RP series

    *3 phase type is also available for 10.0kW,12.5kW and 14.0kW class models.**Only 3 phase type is available for 20.0kW class models.

    *1 phase type models Only.

    ■STANDARD INVERTER Models*

    4 way Cassette

    Ceiling Concealed

    Ceiling Suspend

    Wall mounted

    3.5kW

    1.6HP 2HP 2.5HP 3HP 4HP 5HP 6HP 8HP 10HP

    5.0kW 6.0kW 7.1kW 10.0kW 12.5kW 14.0kW 20.0kW 25.0kWpage

    P52

    P53

    P54

    P55

    P56

    P57

    P58

    Series Name

    SPLZ/PLZ-P series

    SPEDZ-EA/PEDZ-P EA series

    SPEDZ-GA/PEDZ-P GA series

    SPCZ/PCZ-P GA series

    PCZ-P HA series forProfessionalKitchen

    PKZ-P FAL series

    Floor Standing PSZ-P series

  • 2002JSRAE

    TECHNOLOGY AWARD

    2002JSRAE

    TECHNOLOGY AWARD

    Japan Society of Refrigerating and Air Conditioning Engineers

    DC compressor motor ( rotor ) Neodymium magnets

    The reluctance DC motor has a rotor equipped with powerful neodymium magnets. The magnetic torque produced by the neodymium magnets and reluctance torque results in more efficient operation.

    Our unique motor, known as “Poki-Poki Motor“ in Japan, employs joint lap production technique. Originally developed by Mitsubishi Electric, this motor offers high density and high magnetic force leading to high efficiency and high reliability.

    Magnetic torque

    +Reluctance torque

    LEV1

    Powerreceiver

    Heatexchanger

    Heatexchanger

    Compressor

    LEV2

    Mitsubishi Electric has developed a power receiver and twin LEVs (linear expansion valves) that optimise the performance of the compressor. By ensuring optimum control in response to the operating waveform and outdoor temperature, this technology is tailored to the characteristics of the new refrigerant to enhance operating efficiency.

    This intelligent temperature control feature — that adjusts airflow interval to the body depending on air outlet temperature — allows set temperatures to be raised by 2 degrees without any loss in comfort for a 20% gain in energy efficiency.

    Power Receiver and Twin LEV Control

    Joint Lap DC Motor

    “Econo Cool” Energy-Saving Feature

    Conventional Econo CoolAmbient temperature 35°C 35°CSet temperature 25°C 27°C

    temperature 30°C 29.3°C

    “Econo Cool” modeEnsures more comfort even when the set temperature is 2°C higher than the conventional cooling mode.

    “Econo Cool” On Conventional cooling mode

    Thrust gas power: minimum

    Cradle scrollFrame

    Secondary back-pressure chamber minimizes thrust friction loss.

    Primary back-pressure chamber minimizes leakage loss.

    Thrust friction loss: minimum

    Leakage loss: minimumFixed scroll

    The highly efficient scroll com-pressor is equipped with a “Frame Compliance Mechanism” that allows movement in the axial direction of the frame supporting the cradle scroll. This greatly reduces both leakage and friction loss, ensuring very high efficiency throughout the speed range.

    Highly Efficient DC Scroll Compressor

    Frame movable in the direction

    of the axis.

    Remarkablereduction

    in leakage and friction loss

    Without PAM Control With PAM ControlSupplyvoltage

    CurrentTime Time

    PAM adjusts the form of the current wave so that it becomes close to that of the supply voltage wave. High harmonics are reduced and 98% of the electricity is utilized.

    Using a Motorcycle as an example

    PAM

    Energy savings is limited.Fuel is wasted.

    Significant energy savings.Electricity loss reduced for surprising energy savings.

    Power is limited.Power is insufficientfor steep hills.

    Power increased.Efficient increase of voltage for increased power.

    ConventionalInverter

    This diagram illustrates the merits of PAM Control.

    PAM (Pulse Amplitude Modulation)Electricity can be used efficiently with less loss, if the current wave resembles the supply voltage wave. PAM is a method for controlling the form of the current wave so that it conforms to the supply voltage wave. With PAM control, 98% of input power supply can be effectively used.

    Magnetic Flux Vector Sine Wave DriveBy converting the motor’s electrical current waveform from the conventional waveform to a sine wave (180° con-ductance), this microprocessor raises the motor winding utilization ratio and reduces energy loss for higher efficiency.

    A high-efficiency DC motor drives the fan of the outdoor unit. It offers up to 60% greater efficiency than an equivalent AC motor.

    DC Fan Motor

    70%

    80%

    90%

    100%

    Eff

    icie

    ncy

    0 2 4 6 8 10 12 14 16

    Number of Years in Use

    Flat Fin Efficiency

    Conventional Fin Efficiency

    *The initial period is set at 100%.

    Energy Efficiency Stays Strong( 3 times stronger than conventional Fins )

    Highly Reliable Flat FinThanks to the flat fin preventing clogging, the initial high energy efficiency is maintained throughout the unit's long lifespan.

    * Available only during manual cooling operation.

    Inverter & Energy Saving Technology

    ( PUHZ Series )

    ( PUHZ Series , M Series )

    ( M Series )

    Reluctance DC Rotary Compressor( PUHZ Series )

    ( PUHZ Series )

    distribution (°C)

    14 16 18 20 22 24 26 28

    Perceived

    Temperature

    Sine-wave drive soft PWM

    This produces the most efficient waveform in response to varying compressor motor frequency. By improving operating efficiency from low to high speeds, annual electricity costs are reduced.

    Vector-Wave Eco Inverter

    The inverter has been made compact by insert-moulding the circuit pattern in synthetic resin. To ensure quiet operation, soft PWM control is used to prevent the metallic whine associated with conventional inverters.

    Smooth wave pattern

    *These classifications are for Split and Multi-Split type air conditioners.

    Energy Labeling of Air Conditioners

    Outdoor unitIndoor unit

    More efficient

    Less efficient

    Annual energy consumption, kWh in cooling mode(Actual consumption will dependon how the appliance is usedand climate.)

    Energy efficiency ratio Full load (the higher the better)

    Type Cooling only – Cooling + Heating –

    Air cooled – Water-cooled –

    Heat output kWHeating performanceA: higher G: lower

    Noise(dB(A) re 1 pW)

    Further information is contained in product brochures.

    All air conditioners with the cooling capacity under 12kW are concerned.Directive defines for each type of product the energy class going from A (more efficient) to G (less efficient). The energy efficiency class is determined in accordance with the following tables.

    Norm EN 814Air conditionerEnergy Label Directive 2002/31/EC

    Classifications

    Energy Efficiency Class In cooling mode

    A 3.20 < EER B 3.20 ≥ EER > 3.00C 3.00 ≥ EER > 2.80D 2.80 ≥ EER > 2.60E 2.60 ≥ EER > 2.40F 2.40 ≥ EER > 2.20G 2.20 ≥ EER

    Energy Efficiency ClassIn heating mode

    A 3.60 < COPB 3.60 ≥ COP > 3.40C 3.40 ≥ COP > 3.20D 3.20 ≥ COP > 2.80E 2.80 ≥ COP > 2.60 F 2.60 ≥ COP > 2.40G 2.40 ≥ COP

    ProductAir Conditioners

    A B C 1 2 3A B C 1 2 3

    A

    X.Y

    X.YX.Y

    X.Y

    A B C D E F G

    Model Name

    Energy Efficiency Class

    Annual Energy ConsumptionThe Annual Energy Consumption iscalculated with the total input powermultiplied by an average of 500 hoursper year in cooling mode at full load.

    Energy Efficiency RatioHigher EER means better energy efficiency.

    Type of Air Conditioner

    AB

    CD

    E

    G

    Energy

    AIR CONDITIONING SYSTEMSManufacturer

    F

    Cooling output kW

    7 8

  • dB

    Only

    MSZ-FA/GA25

    1/2noise

    Operation has been made very silent by improvements to the design of the fan blades and the new grille shape. The outdoor unit is even more silent when outside temperature drops as it automatically switches to low-noise mode to reduce operating noise by 3dB.

    Silent OperationA low-noise priority function is also available by connecting a commercially available timer or a selector switch. When a signal is received from the timer or the switch, the unit runs in low-noise priority mode.

    Low-Noise Priority Function

    C

    Ultra Silent Indoor Unit OperationNoise level during normal operation is only 21dB for the new MSZ-FA/GA25, making it one of the quietest indoor units in the industry. Inside the unit, the multi-angled heat exchanger has a modified fin shape that reduces air resistance for a smoother, quieter airflow. The wide fan diameter produces greater airflow at lower fan speeds and the uneven pitch between each fan blade helps to eliminate annoying noise. What’s more, the remote controlled vane significantly decreases downward air resistance for much lower noise levels.

    Quiet 4 way CassetteReduced airflow resistanceand a redesigned shape of the heat exchanger fin make very quiet operation.

    Q. A.In general, why is the reuse of existing

    pipework not allowed for models with

    R407C or R410A HFC refrigerant?

    This is because existing pipework contains moisture and chloride residue that, when mixed with compressor's ester oil, can result in a chemical reaction. Additionally, refrigerant oil sludge and corrosion within the compressor can clog up the refrigerant circuit.

    Our Inverter-driven models are the first in the industry to use hard alkyl benzene (HAB) oil — a unique refrigerant oil that degrades very slowly — for refrigeration. Employing our exclusive cleaning-free technologies such as a specially developed high-efficiency oil separator and optimum distribution of heat exchangers to prevent oil stagnation, we have made it possible to reuse previously installed pipeworks.

    MSZ Series, MXZ Series (except for MXZ-8A140VA),PUHZ-RP35/50/60/71 Features

    New HAB Refrigerant Oil The refrigerant oil (ester oil) used for the 10.0~25.0kw models will degrade when mixed with chemicals such as chloride found in existing pipes. To prevent oil degradation and make it possible to reuse existing pipes, Mitsubishi Electric has developed an exclusive replacement filter that uses activated charcoal to soak up chlorides.

    PUHZ-RP100/125/140/200/250 Features

    Exclusive Replacement Filter

    Mitsubishi Electric’s Cleaning-Free Technology

    Replacement filter (conceptual diagram)Refrigerant circuit lasts longer with less deteriorationusing the new HAB refrigerant oil*

    *Data taken from our lab: Test results equivalent to 10 years worth of use

    Characteristics of the newrefrigerant oil

    Colour of the oilat initial stage

    Colour of the oil at10 years after use

    Name: HAB Oil

    Oil characteristics:

    Difficult to dissolve in the refrigerant.High chemical and heatstability, uniform quality, high fluidity and viscosity.

    Activated carbon (absorbs chlorine and other chemicals)

    Filter Outlet

    RefrigerantRefrigerant

    Inlet

    1

    2

    Silent Operation Technology Cleaning-Free, Pipe Reuse Technology

    DAY

    50dBin

    cooling mode

    NIGHT

    47dB*in

    cooling mode

    ( PUHZ and Power Multi )

    Indoor Unit

    Outdoor Unit

    dB

    Only

    PLA-RP35AA

    • Reduces installation time for less disruption of business.• Saves installation costs.

    • Installation time is reduced significantly, so you have more time to do other work.• Not necessary to find proper pipings for R410A refrigerant.• Time-consuming pipe cleaning is not necessary, even if the owner wants to reuse the existing pipework.

    Advantages

    For tenants /owner

    For installer

    Refrigerant condensed in the condenser of the outdoor unit is heat-exchanged with the low temperature refrigerant inside the accumulator, and subcooled. Doing this way, refrigerant will reach the LEV (Linear Expansion Valve) while keeping the optimum state even when the branch box is installed far from the outdoor unit. This has enabled to reduce the refrigerant noise at the LEV section, and has optimized the refrigerant distribution to each indoor unit, proving great effectiveness in the installation environment with a large piping loss (pressure loss) due to a long piping length or a large height difference.

    Reduction of Refrigerant Noise

    PUHZ-RP125/140:

    9 10

  • PAR-21MAA

    The air conditioning operation can be switched off automatically thus preventing

    waste operation. The set time can be changed from 30 minutes to 4 hours at 30-minute intervals.

    Operation Control Function

    Auto Off timer

    Operationlocking

    Equipped with the Long Awaited Weekly Timer

    Easy-to-read / Easy-to-use

    The setting of the upper and lower limit temperature is possible. This prevents excessive cooling and heating leading to contribute in saving energy.

    Limitingthe set temperaturerange

    Air conditioning operation Air conditioning operation always within a limited always within a limited temperature rangetemperature range

    The function of the weekly timer equipped can change the set temperature in addition to the ON/OFF control. Up to 8 patterns can be set for each calendar day.Industry First!

    Multi-language Display

    [Japanese]

    [English] [Italian] [German][Spanish]

    [Russian] [Chinese][French]

    Display can be switched overfor 8 kinds of language.

    8 languages 8 languages can be displayed.can be displayed.

    Weekly timer function capable of temperature control

    Automatic turning off of Automatic turning off of air conditioning operationair conditioning operation

    Preventing the randomPreventing the randommodification of settingmodification of setting

    Busytime frame

    Setting to higher temperature

    Less busy time frame

    4

    PAR-20MAAConventional MA remote controller

    PAC-YT34STASchedule

    timer PAR-21MAA-Gremote controller

    Setting Example (Restaurant in summer time)

    NEW

    Employment of Dot Liquid Crystal Display

    Display example [Operation mode]

    Acknowledging the operation and control status at a glance. The large size display upgrades visual acknowledgement capability. The operation and control status can be understood promptly.

    Effective in energy saving control

    Dot liquid crystal display section

    Renovating air conditioning communication by advanced MA Remote Controller newly developed

    Economical&

    Space savingMulti-Ianguage

    Control Technology

    26

    25

    24

    23

    22

    0 10 12 14 16 18 20 22 24

    Set

    tem

    per

    atu

    re(˚

    C)

    Opening time

    Lunch time Dinner time

    Setting of 7 patterns

    Closing time

    Setting to lower temperature

    1

    2

    3 5

    6 7

    (Hr.)*Result of cooperative study with Japan Facility Solution Co, Ltd.

    COOL / DRY

    Office RestaurantRecommend to use in

    Lower limit temperature

    Possible setting range (standard)

    19(˚C) 30(˚C)

    30(˚C)25(˚C)

    To prevent excessive coolingThe lower temperatures cannot be selected.

    Meeting roomRecommend to use in

    * The "Simple timer" (starts and stops in a unit of one hour within 72 hours) set at factory shipment can be changed to the "Auto off timer" by switching the function of the remote controller.

    * The change of setting may be limited to the administrator who knows the method to release the locking.

    Public facility like public hall

    Recommend to use in Office School / private school

    Hospital Server room

    Setting to invalidate all buttons or the operation other than with ON/OFF button

    is available. This always assures operation under an adequate temperature preventing the meaningless change of set temperature, leading to effective energy savings. This is also effective to prevent erroneous or mischievous operation.

    about10%Energy Saving

    *Setting the temperature to “1˚C higher in cooling”while “1˚C lower in heating” results in about 10% energy saving. *Based on our internal calculation

    ON/OFFTEMP.

    Conventional inspection work

    Easy maintenance information

    Easy Maintenance Function (Only for Power Inverter Mr.Slim) Reduces maintenance work drastically. Enables you to check operation data of the indoor and outdoor units by remote controller. Furthermore, you can fix the operating frequency, from the remote controller for smoother inspection.

    Refrigerant Leakage Check (only for PUHZ-RP HA2) The latest “Power Inverter” Mr. SLIM (PUHZ-RP HA2) has got a new useful “Refrigerant Leakage Check” function.With this function, the refrigerant leakage which may happen during a long period of use can be easily checkedwith a wired remote controller. Not only time for servicing can be saved, but you also get peace of mind.

    Accumulated operating time (x10 hours)

    Number of ON/OFF times (x100 times)

    Operatingcurrent (A)

    Heat exchanger temperature (˚C)

    Dischargetemperature (˚C)

    Outdoor air temperature (˚C)

    Intake air temperature (˚C)

    Heat exchanger temperature (˚C)

    Filter operating time* (Hours)

    Outdoor unitCompressor Indoor unit

    1

    2

    3

    4

    5

    6

    7

    8

    9

    *The filter operating time is the time elapsed since the filter was reset.

    Discharge temperature 64˚C

    Indoor unit Outdoor unit

    Remove the service panel

    Measurethe intake air temperature

    Measure the discharge temperature

    Measure the outdoor air temperature

    NEW!

    11 12

  • 1

    2

    3

    4

    5

    1-remote controller control

    Standard System

    2-remote controller control

    With 2 remote controllers, control can be performed locally and remotely from 2 spots.

    Group Control

    One remote controller can control plural air conditioners simultaneously under a same setting.* The setting of the refrigerant add-

    ress is required for outdoor unit.

    Operation Control by Level Signal (DC12V)

    Air conditioner can be started/stopped remotely. In addition, the ON/OFF by local remote controller can be prohibited/permitted.

    Operation Control by Pulse Signal

    Remote Display of Operating Status

    Operating status can be displayed at a distant place.

    Allows ON/OFF with timer *For the control by external timer, refer to D Operation Control by Level Signal.

    Centralized control of dispersed air conditioning equipment allows effective monitoring/controlling.

    LOSSNAY can be controlled with remote controller

    Timer Operation

    Centralized Control

    Interlocking with LOSSNAY

    SYSTEM CONTROLS

    PAR-21MAA-G

    (Example of 1 : 1 system)

    Signal receiver

    PAR-21MAA-GPAR-21MAA-G

    (Example of 1 : 1 system)

    (Example of 1 : 1 system)

    (Example of 1 : 1 system)

    PAR-21MAA-G

    Relay box (to be purchased) locally)

    Relay box (to be purchased) locally)

    Adapter for remoteON/OFF

    Adapter for remoteON/OFF

    Indoor CN51

    PAR-SL97A-E

    PAR-SL97A-E

    (Example of 1 : 1 system)

    PAR-21MAA-G

    (Example of 1 : 1 system x 2)

    (Connection with M-NET system)

    Centralized remote controller G-50, etc.

    Power supply unit

    LOSSNAY operation cable

    LOSSNAY

    Wired remote controller

    M-NET adapterPAC-SF80MA-E

    Indoor CN51

    Remote operation adapter

    (Example of 1 : 1 system x 2)

    Relay box (to be purchased locally)

    (Example of 1 : 1 system x 2)

    * Set "Main" and "Sub" remote controllers. * When you use wired and

    wireless remote controllers

    PAR-SL97A-E

    (Example of Simultaneous Twin)

    PAR-SL97A-E

    (Example of Simultaneous Twin)

    (Example of Simultaneous Twin)

    PAR-SL97A-E

    (Example of 1 : 1 + Simultaneous Twin)

    • Wired Remote ControllerPAR-21MAA-G

    • Wired Remote Controller Kit for PKAPAR-21MAAT-E

    • Wireless Remote ControllerPAR-SL97A-E

    • Wireless Remote Controller Kit for PCAPAR-SL99B-E

    • MAC-397 IF-E is required for each indoor unit if the outdoor unit is SUZ or MXZ. (If the outdoor unit is P series,

    no optional parts are required.)

    • Adapter for remote ON/OFFPAC-SE55RA-E

    • Relay box (to be purchased locally)• Remote control panel (to be purchased

    locally)

    Standard functions of PAR-21MAA-G

    M-NET adapter:PAC-SF80MA-E

    *If the outdoor unit is SUZ or MXZ,please refer to [1] 2 on page 13

    SLIM-LOSSNAY connection cable

    Versatile system controls can be realized by using optional parts, relay circuits, control panels, etc.

    A

    B

    C

    D

    E

    F

    G

    H

    I

    Details Major optional parts requiredSystem examples

    Wired remote controller Wireless remote controller

    Remotedisplaypanel

    Remotedisplaypanel

    Indoor CN32

    PAR-21MAA-G

    Remotecontrolpanel

    RemotecontrolpanelWired remote

    controller

    Wired Remote Control

    Centralized Control

    Remote ON/OFF Operation

    Remote Display of Operation Status

    Interlocking with LOSSNAY

    [1] For M series Indoor Units (New A-control models only) [2] For P series and S series Indoor Units

    Control detail Major optional parts requiredSystem examples Connection detail

    • MAC-397IF-E (Interface)• PAR-21MAA-G (Wired remote controller)

    • MAC-397IF-E (Interface)• MAC-821SC-E (Centralized remote controller)

    • MAC-399IF-E (M-NET Interface)• Centralized controller for City Multi, like G50, and power supply unit, etc.

    • MAC-397IF (Interface)• Parts for circuit such as relay box, lead wire, etc. (to be purchased locally)

    • MAC-397IF-E (Interface)• Parts for circuit (to be purchased locally/ DC power source needed)

    Wired remote controller can be connected to indoorunit via interface.

    Centralized remote controller can be connected to each indoor unit via interface.

    M-NET connection is possible via interface.

    Connect interface to air conditioner and setup a circuit by using the terminal inside theinterface locally.

    Connect interface to air conditioner and set up a circuitby using the terminal inside the interface locally.

    LOSSNAY can be connected to indoor unit via an interface.

    With wired remote controller, operation mode/set temperature/fan speed/vertical air direction*1, and timer operation *2 can be controlled.

    Individual ON/OFF and switching OFF at a time is possible with centralized controller.The ON/OFF status of each unit can be confirmed by the LED on the centralizedremote controller.

    Individual ON/OFF and switching OFF at a time is possible.Operation mode, temperature/fanspeed/air direction*1 andtimer settings *2 can be changed individually.

    ON/OFF is possible from a distant place

    The operation status (ON or OFF) or error signals can be monitored from a distant place.

    LOSSNAY can be operated simultaneously with the indoor unit.

    • MAC-397IF-E• Cable for LOSSNAY connection (to be purchased locally)

    • Up to 8 indoor units can be switched ON/OFF with one remote controller.

    • Air conditioner can be group controlled with City Multi (M-NET).

    • Air conditioners can be controlled by wired remote controller equipped with Weekly Timer function.

    For further details, refer to the separate manual.*1 Not applicable to the models without air direction control.*2 For timer setting, do not use the wireless and wired remote controllers together.

    Outdoor unit

    Indoor unit

    MAC397IF-E

    PAR-21MAA-G

    Indoor unit

    MAC-821SC-E

    MAC-397IF-E

    City Multi outdoor unit

    City Multi indoor unit

    MAC-399IF-E

    ME remote controller (PAR-F27MEA)

    Localremotecontroller

    City Multi indoor unit

    G-50, etc.

    Power supply unit

    Outdoor unit

    Indoor unit

    MAC-397IF-E

    Remote control section(to be purchased locally)

    Switch

    Outdoor unit

    Indoor unit

    MAC-397IF-E

    Remote monitor section (to be purchased locally)

    Power supply

    MAC-397IF-EOutdoor unit

    Indoor unitLOSSNAY

    Outdoor unit

    Resistance LED

    • Either wired type or wireless type remote controller can be used.

    • Up to 2 remote controllers canbe connected to 1 group.

    • Both wired and wireless remote controllers can be used in combination.

    • One remote controller can control up to 16 refrigerant systems.

    • Outdoor unit can be started/ stopped (thermostat ON/OFF) individually.

    • Up to 2 remote controllers can be connected.

    • Operation other than ON/OFF (adjustment of temperature, fan speed, and air direction, for example) can be performed even when remote controller operation is prohibited.

    • Timer control is possible with an external timer.

    Adapter for remoteON/OFF

    Adapter for remoteON/OFF

    PAR-SL97A-E

    (Example of 1 : 1 system x 2)

    Relay box (to be purchased locally)

    (Example of 1 : 1 system x 2)

    • Adapter for remote ON/OFFPAC-SE55RA-E

    • Relay box (to be purchased locally)• Remote control panel (to be purchased

    locally)Indoor CN51Remotecontrolpanel

    RemotecontrolpanelWired remote

    controller

    • Operation other than ON/OFF (adjustment of temperature, fan speed, and air direction, for example) can be performed even when remote controller operation is prohibited.

    • Timer control is possible with an external timer.

    • Operation/emergency signal can be received at a distant place (no-voltage signal).

    • Weekly timer:ON/OFF and up to 8 pattern temperatures can be set for each calendar day.(Initial setting)

    • Simple timer:ON/OFF can be set once each within 72 hr. in a unit of one hour.

    • Auto-off timer:Operation will be switched off after elapsing a certain time. Set time can be changed from 30 min. to 4 hr. at 30 min.

    intervals.*Simple timer and Auto off timer cannot be used at the same time.

    • Mounting the adapter for M-NET connection to the outdoor unit allows MELANS (M-NET system) connection.

    • Allows centralized control by MELANS.

    • LOSSNAY can be connected to the indoor unit.

    None

    • Remote display panel (to be purchased locally)

    • Remote ON/OFF adapterPAC-SE55RA-E

    • Connector cable for remote displayPAC-SA88HA-E/ PAC-725AD (10 pcs. x PAC-SA88SA)

    • Remote operation adapter PAC-SF40RM*Unable to use with wireless remote controller

    • Remote display panel (to be purchased locally)

    • Air conditioner can be started/stopped remotely.( 3 and 4 can be used in combination)

    • The ON/OFF status of air conditioner can be confirmed remotely.( 3 and 4 can be used in combination)

    • LOSSNAY can be operated simultaneously with the indoor unit.

    MAC-397IF-E*

    MAC-397IF-E*

    NOTE: TWIN,TRIPLE,QUADRUPLE Operation is possible only in the limited combinations. Please refer to page 90 for details.13 14

  • Plasma Deodorizing FilterThe newly equipped "Plasma Deodorizing Filter" provides state-of-the-art deodorization-decomposition and elimination of harmful chemical substances at the nanolevel (1/1,000,000 of a millimeter). The key to high power deodorization of the most unpleasant odors*1 in daily life such as ammonia, methyl mercaptan, trimethylamine and hydrogen sulfide.

    ■ Maintenance is a snap - just wash these units in water!

    ■ removes various things

    To care for both the Plasma Deodorizing Filter and the Plasma Air Purifying Filter, just wash them in water. The deodorizing ceramic filter, meanwhile, is an extended use model, boasting a service life of about 6 years.

    Plasma Air Purifying FilterArmed with the "Plasma Air Purifying Filter," which has already built up a solid reputation in Japan, the pollutants in your room air are removed thoroughly than ever before. Besides collection of fine house dust, pollen and other annoying substances, this filter also provides disinfecting and anti-virus effects.*2 Negative ions, with their soothing and relaxing effects, are also generated.

    *1: Not all odor components generated on a continuous basis (building material odors, pet odors) can be removed.

    *2: Source: KRCES-Bio study Report No.16 00865 (November 22, 2004)

    Bad Odors FormaldehydesmokeDust

    Powerful Collection Powerful Deodorization Bacteria Elimination

    Mold spores, Pollen

    VirusesBacteria

    ■ Plasma Air Purifying Filter mechanism

    ■ Plasma Deodorizing Filter mechanism

    Electrically conductive and semi-insulatingresin adsorption componentCatches electrified particles.

    Deodorizing Ceramic Filter

    GND electrode

    Plasma electrode unit

    GND electrode

    ■ Plasma Deodorization,s Effect on Ammonia

    100%

    80%

    60%

    40%

    20%

    0%

    With Plasma Deodorization

    Without Plasma Deodorization

    Operation time ( minutes )100 20 30

    Am

    mon

    ia o

    dor r

    esid

    ual r

    ate

    Plasma electrode unitThe dirty molecules are electrically charged, while odor molecules decomposed down by radicals.

    *1.1wh each for Plasma Deodorizationand Plasma Air

    Purification.

    Quick Clean

    With our new moving "i see sensor",no temperature gap goes free.

    Plasma Air Purifying FilterAnti-mold Pre Filter

    Vane

    Plasma Deodorizing Filter

    Front Panel

    The inner fan is placed within ready reach, for handy cleaning.

    The moving "i see sensor" automatically moves from side to side, searching out temperature disparities over a wide area of 150°. Thanks to this advanced sensing technology, and the wide airflow of 150° from left to right (90° in cooling mode), all corners of even the most spacious rooms are kept comfy.

    Warmer area

    Warm air aims the cooler areas.

    Cooler area

    Warm air aims the cooler areas.Daytime Nighttime

    ■ In heating mode (with AREA setting : whole room)

    Fan Guard

    With the AREA button, efficient, energy-skimping heating and cooling is realized for the target space – the right side, left side or the room as a whole. The sensor also operates only on the selected side.

    “Area Setting”– for waste-free, energy-saving heating and cooling.

    Advanced airflow control supported by a newly configured horizontal vane enables the warm air to reach the floor level in heating mode. In cooling mode, the vane angle can be kept nearly horizontal, for a pleasant and refreshing feeling that comes out more health conscious all around.

    Airflowdistr ibut ioncomparisons

    Model from 10 years ago

    Vertical section Horizontal section

    MSZ-FA

    *in heating mode : outdoor temperature 7°C / room size 13.2m2

    ■ An improved "horizontal vane," for even more pleasant and refreshing airflow

    Wide Detection

    When choosing an air-conditioner, besides the natural yardstick of comfort, interior compatibility is another key choosing point. At Mitsubishi Electric, our highly compact and refined designs provide excellent fits for a vast range of rooms. The “glossy pure white” hue, meanwhile, will accentuate your attractive interior with yet another eye-catching touch.

    Auto Front PanelTurning the unit “ON” makes the front panel to open, activating the cooling or heating operation. Switch “OFF” and the panel closes, striking a smart and sleek appearance to the eye.

    When not in use

    198mm*

    Compact design, only 780mm wide. Just right for your home interior.

    780mm

    *

    A ceramic filter equipped with newly developed nano-hole manganese catalyst. Engineered for streamlined catching and crushing of odor-causing elements over an impressive surface area of 1,750m2 (approx. 7 tennis courts).

    Heating at -20˚CPossible with the models mounted with the anti-freeze heater on the outdoor unit drain pan.

    ※2.5kw class

    The easily detachable front panel is a snap to wash, and the airflow vents can be opened without any special tools for quick cleaning inside the air conditioner. It is recommended that the air conditioner be cleaned regularly, to increase operating effi-ciency and energy savings alike.

    Quick Clean Design slashes your electric bill by approx. 30%*3

    Quick Clean Kit is easily connected to household vacuum cleaners*4

    *3 Electric bill comparisons of the operation at fixed temperature with 8 g of dirt on the fan and the one without. Based on the in-house data. *4 The wearing of gloves is highly recommended when cleaning the heat exchanger, because touching the heat exchanger with bare hands can cause injury.

    Exclusive Quick Clean Kit (standard)

    In order to completely satisfy human thermal sensation,even the floor/wall temperature in addition to the room temperature are measured by our . This results in more effective cooling and heating with less waste operation.

    Roomtemperature30.9%

    Humidity20.7%

    Floor/walltemperature43.7%

    Decisive factors for sensible temperature (in a room)

    FA SeriesThe Plasma Duo goes beyond just catching the unpleasant odors, and proceeds to powerfully crush them. The all-out pursuit of real air quality.

    15 16

    AREA

  • MFZ SeriesFor your Living Room, or Bed Room.The latest Mitsubishi innovation – floor standing air-conditioner sophisticated in design, rich in function.

    i save mode

    Optimum Air Distribution Cleaner and Healthier Air

    Trouble-Free Installation and Maintenance

    Sophisticated Design

    Slim but Mighty

    Quiet Operation

    From Mitsubishi Electric, an innovative new floorstanding air-conditioner. Our pleasing mix of streamlined form and diversified function. Engineered to keep room walls free, furnish comfy cooling in summer, toasty heating in winter. The “Glossy Pure White” colour ensures a deluxe look, the perfect match for any room. Both upper and lower air outlets remain closed when switched OFF, in a smart and striking image. A superb new air-conditioner from Mitsubishi, providing a handsome fit for your own distinctive interior.

    The unit body is slim and trim, the essence in compact. An ideal size for living rooms, bedrooms, attics and more.The removable and washable front panel makes cleaning a snap.Easy and regular cleaning allows your air-conditioner stay beautiful while keeping its energy efficient operation always possible.

    Comfy room temperatures are realized by the optimum, powerful and efficient air distribution through upper and lower air outlets.The upper vane angle is remote controllable, with 5 air flow direction levels (+ Swing and Auto modes) and 4 wind power levels (+ Auto mode).By setting the vane angle almost vertical, annoying direct wind can be avoided for your better comfort.

    A simplified set back function enables to recall the preferred (preset) temperature with a single push of the button on the remote controller. Press the same button again and you can go back to the previous temperature setting in an instance.When leaving the room, going to bed or at other times, this button helps you to realize the wisest and the most suitable air conditioning. A handy function for comfortable and waste-free environment pursuit, the Mitsubishi way.

    To install the indoor unit, position with our original installation plate, then set the unit place. Easy leveling work prevents any harm towall surfaces. Generous pipe length, up to 20 or 30 meters, eliminates worries about outdoor unit distance. Loaded with automatic diagnosis function, trouble log recall mode and other sophisti-cated aids, troubleshooting is immediate though pro-blems are rare.

    The air from both upper and lower air outlets is optimally controlled and distributed evenly to every corner of the room. In heating mode, the warm air is smartly controlled to stay at the floor level: Your feet do not feel chilled any more!

    Waste-free operation – energy-stingy to the hilt.The optional wired remote controller (PAR-21MAA)* with “Weekly Timer” function enables 8 separate pattern settings over a single day’s time. Use the optional “Centralized ON/OFF Controller (MAC-821SC-E)*” to exercise regulate all rooms. ON/OFF selection and operation status con-firmation is possible with a single controller.

    700mm

    60

    0m

    m

    200mm

    ■ "Anti-Allergy Enzyme Filter" mechanism

    ■ Smarter Control, with a Single Remote Controller

    SS

    ArtificialEnzyme

    ArtificialEnzyme

    CatechinFilter

    TransformationTransformation

    Transformed protein =Non-allergen proteins

    Allergen protein (Such as mites)

    S

    S

    Filament Filament

    Artificial enzyme catalyst on the filament catches the allergens.The artificial enzyme cata-lyst helps the chemical reaction with Oxygen and severs the S-S bonds.*4

    Proteins with severed S-S bonds are no longer aller- gen proteins.

    *4: Mites and other allergen protein consist of sulfur atoms (S) that have bonded together.

    Transformation

    *1 : "Inactivation" refers to curbed activity. *2 : Confirmed by the Japan Spinners Inspecting Foundation. Test numbers JSIF-029220-1/JSIF-029220-2. *3 : Confirmed by Shinshu University.

    Catechin + Anti-Allergy Enzyme Filters Achieve deodorization, allergen inactivation,*1 bacteria elimination*2 and antiviral effects. Elevating the pursuit of health-conscious air to unequaled heights. In addition to the "Catechin Filter" with deodorizing effect, the"Anti-Allergy Enzyme Filter" catches dead mites and their droppings, pollen and other allergens on the filter filament, then decomposes them with artificial enzymes*3. What's more, the steriling agent generates greater antiviral effects, supporting a cleaner and healthier air supply.

    i save

    Mitsubishi Electric air conditioners have always been some of the quietest models available in the market. Our new floor standing models are no exception.It can create a silent and comfortable space where the occupants would not even recognize the existence of air conditioner operation.

    Sleek louvers look just like flat panels

    Smart upper/lower air outlets close when switched off

    Deluxe look in “Glossy Pure White” color

    ● Installation Plate

    ● Noise level

    *requires special interface(MAC-397IF-E)

    PAR-21MAA

    MAC-821SC-E

    Anti-AllergyEnzyme Filter

    10dB40dB60dB80dB

    Subway car interior

    Quiet passenger car interior (40km/h)

    Library interior

    Human hearing limits (Extremely quiet)

    Sound of rustling leaves

    22dB

    ※2.5kw class

    thequietest!

    22℃ 18℃

    14 16 18 20 22 24 26 [℃]

    22※

    17 18

    * It is recommended to soak the filter in water every three months. The standard interval of filter replacement is for one year.

    i save

  • Before replacement:Installed 8 years ago

    Model name PLH-3GKHB/PUH-3YKA

    After replacement:Power Inverter

    Model namePLA-RP71AA/PUHZ-RP71VHA

    Conditions of trial calculation ( according to Japan Refrigerant Association )

    Power Inverter Non-Inverter (R407C)

    COP

    Outdoor Unit

    3.5

    3.0

    2.25

    3.60

    3HP

    2.61

    3.30

    4HP

    2.55

    3.21

    5HP 6HP1.6HP 2HP 2.5HP

    2.17

    3.23

    2.42

    3.36

    2.40

    3.64

    2.40

    2.81

    Average

    38%increase

    Comparison of COP between non-inverter and power inverter (4-way cassette type) models.

    70%reduction

    60%UP

    52%UP

    26%UP 26%

    UP49%UP

    39%UP

    R407CNon-Inverter

    R410APower Inverter (Maximum capacity)

    1.6HP 4.4 4.5 102%2HP 5.3 5.6 106%

    2.5HP 6.3 6.7 106%3HP 7.7 8.1 105%4HP 9.6 11.4 119%5HP 12.7 14.0 110%6HP 14.2 15.3 108%8HP 20.9 22.4 107%10HP 26.0 28.0 105%

    Cooling capacity

    3HP 3.3-8.1 kW

    5HP 5.5-14.0 kW

    4HP 4.9-11.4 kW

    6HP 5.5-15.3 kW

    8HP 10.0-22.4 kW

    10HP 12.5-28.0 kW

    0 2 4 6 8 10 12 14 16 18 20 22 24 26kW

    Cooling capacity ranges

    Running current comparison.

    The cooling & heating capacities at the maximum operatingspeed have also been improved by up to 33% compared to the current model.

    Operation is now possible at lower speeds, thus cutting energy losses produced by the repeated on/off operation of non-inverter models. Comfort is improved while power consumption is reduced.

    Higher Cooling & Heating Power Wider Performance Range

    3 phase power supply "Power Inverter" (RP100 - 250YHA)

    The other features; *Replace filter equipped (to Reuse the existing pipe works) *High efficiency operation *Silent operation (Only 52dB in silent mode: 20.0kW)

    Compact top flow models(20 & 25kW Power Inverter)

    By additional filling with refrigerant, it is now possible to have pipes up to 120 metres long, making it easier to select a layout to install the unit.

    Dramatic reduction of running current is realized by 3 phase power supply. The special technology is installed in the outdoor unit to comply with the Electro Magnetic Compatibility in Europe.

    Harmonics Filter Technology

    We have successfully complied with the EMC regulations (EN61000-3-2,Class-A) first in the industry in the category of 3 phase inverter driven air conditioners requiring less than 16A current input.

    Less than half in the running current and the breaker size !!

    The Other Features -20˚C Heating is possible

    (for RP100/125/140/200/250)

    Cleaning Free Pipe Reuse. Silent Operation (outdoor unit)

    Longer Piping Length

    Max Height difference Max piping Length

    PUHZ-RP35/50

    PUHZ-RP60/71

    PUHZ-RP100/125/140

    30m

    30m

    30m

    50m

    50m

    75m

    PUHZ-RP200/250 40m 120m

    Max Piping Length can be stretched to 120m1. Power Consumption

    Energy Saving

    2. COP

    Based on our calculations on the operating conditions shown below, the new Power Inverter system can reduce power consumption by approxi-mately 70% compared to an old model installed 8 years ago.

    17%UP

    990

    300

    990

    500

    750

    900

    100

    450

    198kg225kg

    1.97m2 1.17m2

    3 phase

    1 phase

    Rated (cooling)

    Rated (heating)

    Max

    Breaker size

    Rated (cooling)

    Rated (heating)

    Max

    Breaker size

    3.79

    4.33

    13

    16

    12.33

    13.94

    28

    32

    4.85

    5.41

    13

    16

    15.8

    17.5

    28

    32

    6.49

    6.37

    13

    16

    20.73

    20.37

    29.5

    40

    10kW

    990990 750

    900

    Unit size

    Unit: mm

    Unit: mm

    SpaceforServicing

    PUH-8YD New Power InverterPUHZ-RP200YHA

    DepthReduced by240mm

    WeightReduced by

    Space for Servicing

    *In case of installing one intake/blow off open unit

    27kg

    Service spaceReduced by 40%

    Outdoor Units

    Wall Mounted4 Way Ceiling Cassette

    Ceiling Concealed

    Professional Kitchen

    Floor Standing

    Ceiling Suspended

    Thanks to the new Power Inverter system, a large reduction in power consumption is now possible. This results in one of the highest COP ratings in the industry, helping to lower overall running costs and providing great savings to customers.

    Power Inverter

    Indoor Units

    converter circuit

    1.6HP 1.6-4.5kW

    2HP 2.3-5.6kW

    2.5HP 2.7-6.7 kW

    12.5kW 14.0kW

    The greatly improved COP contributes to reduce your electricity bills drastically.

    Comparison of unit size and space for servicingPlace Office in Tokyo (Japan)

    Operatingtime

    8AM to 8PM (12 hours/day)& 6 days/week

    Settemperature Cooling: 27°C, Heating: 20°C

    Cooling: April 16 ~ November 8Heating: December 14 ~ March 23

    Operatingperiod

    19 20

  • Standard InverterOur New Inverter Features Energy Saving, Compact Design, Light Weight, and Basic Performances as well.

    Pump down switch

    Pump down switch

    Indoor unit control circuit board

    SUZ-KA35VA SUZ-KA50/60/71VA

    PUHZ-P100 PUHZ-P125/140

    To meet your interior or space designing, optimum indoor units can be selected from 8 types that include 4-way ceiling cassettes.A combination with different type indoor units in two or three rooms besides 1:1 combination can be constituted thus satisfyingvarious applications.

    The silent operation of the outdoor unit Model P100 has attained down to 50dB (cooling).Further 3dB can be reduced under the Silent Operation Mode.

    -15℃ OK!

    Merely pushing a switch starts / stops refrigerant recovery operation auto-matically. This work will be completed only by closing a valve.

    New refrigerant R410A with zero ODP (Ozone Depletion Potential) is employed. Smooth refrigerant recovery can be assured by only pushing the pump down switch at unit movement / renewal.

    4 Way Ceiling CassettePLA-AA

    Ceiling ConcealedPEAD-GA

    Ceiling ConcealedPEAD-EA

    Floor StandingPCA-GA

    3dB reduction

    Reducing sound more by Silent Control!

    Day

    Outdoor temperature: 35℃

    50dBNight

    Outdoor temperature: 25℃

    47dB

    Model P100 (cooling)Suppressing to

    about 1/2 audible sound (compared to daytime)

    Photo indicates for Model P100.

    Possible CombinationsCapacity

    PEAD-EA

    PEAD-GA   

    PLA-AA ●

    PCA-GA ●

    PCA-HA  

    PKA-GAL ●

    PKA-FAL    ●

    PSA-GA   ●

    50/60/71 models are for Twin & Triple use.

    5.0kW

    6.0kW

    7.1kW

    10.0kW

    12.5kW

    14.0kW

    Possible CombinationsCapacity

    PEAD-EA

    PEAD-GA   

    SEZ-KA ●

    SLZ-KA ●

    PLA-AA ●

    PCA-AA●

    SUZ-KA35

    SUZ-KA50

    SUZ-KA60

    SUZ-KA71

    21 22

    Greater Energy Saving When Compared to Fixed Speed Unit

    A Product Line of 31 Models in 8 Types Responds to Your Versatile Needs.

    S series outdoor unit can be connected not only with SLZ and SEZ but also some P series indoor units. Greater inverter line up satisfies your various requirement.

    Another possibility! Compact S series outdoor unit can now be connected to P series indoor unit as well.

    Design with Environmental Consideration

    Heating Operation Possible Even at -15˚C Outside Temperature

    Easier Installation Work Thanks to Compact and Light Weight Design

    For Easier Installation

    Silent Outdoor Unit

    COP improved by 27%

    2.61

    2.61D

    2.69

    2.69E

    EER COP

    3.413.41B

    COP

    3.01

    3.01B

    EER

    Comparison with 4-way cassette (4HP) models

    New inverter PUHZ-P100V

    R407C Fixed speed unit PUH-P100V

    Reduced by

    407mmReduced by

    46kgReduced by

    317mmReduced by

    22kg

    R407 Fixed Speed New Inverter75kg 75kgPower Inverter New Inverter

    407mm

    121kg 97kg

    900mm330mm

    1350mm

    1260mm

    943mm

    950mm 950mm330mm330mm

    The outdoor unit model P100 counts for 943mm only for the height and 75kg for the mass. A significant weight reduction of 46kg has been attained compared to the Power Inverter. The burdening of installation/transportation work can be lightened by the compact design and light weight.

    ●Refrigerant piping can be extended up to 50m by charging refrigerant additionally.

    ●Slenderized piping facilitates installation workSlender pipe employed provides easier bending work, minimizes working

    hour and saves materials leading to cost reduction.

    ●4-way piping connections Piping can be connected in the direction of front, rear, bottom and right.

    Dividing the piping cover panel into two portions improves workability of

    internal piping.

    ●Compared to Power Inverter ●Compared to fixed speed unit

    P100

    P125 / 140

    P100 / 125 / 140

    Chargeless piping length

    20m

    30m

    R410A New Inverter

    φ9.52 / φ15.88

    R407C non Inverter

    φ9.52 / φ19.05

    Maximum piping length

    50m

    50m

    (Liquid pipe / gas pipe) Unit: mm

    317mm

    943mm

    950mm330mm

    Outdoor Unit Indoor Unit

    Outdoor Unit Indoor Unit

    NEW!

    NEW!

    NEW!

  • MXZ seriesOur Strengthened MXZ Lineup Provides a Quiet,Highly Efficient and Flexible Air Conditioning SystemFor All Your Air Conditioning Needs

    MXZ-A14/18WV MXZ-2A

    Down weighted by

    12kg

    Downsized by

    30%

    Compact Outdoor Units 40kgNEW

    10~15m30~70m

    30~70m

    285800330 840

    640

    550

    OutdoorUnit

    Branch Box

    Up to 8 indoor units can be connected !

    Suggestion for indoor unit selectionFor a large living room, the Ceiling Concealed or

    the Compact Floor Standing type easily match the fancy interior.For a bed room, the Wall Mounted type creates

    a more silent atmosphere.For 600 x 600 system ceiling, the SLZ type

    facilitates your installation work.For a larger meeting room and the like,

    the PLA type offers the powerful performance.

    Advantage of Power Multi System

    The latest technology obtained through the development of our well-reputed Power Inverter series offers the higher COP, the industry top class.

    The Power Multi runs so smooth and quiet, you get comfort without any of the bothersome noise. Under low operating load, the “Low-noise” mode will automatically be selected thus providing more silent operation. Connecting with our latest wall mounted indoor units allows creating a silent and comfortable space where the occupants would not even recognize the existence of air conditioner operation.

    Not only the branch box simplifies the piping work, the flare connection adopted eliminates the use of fire for easier and safer installation.

    High COP

    The MXZ-2A/3A/4A can be connected to maximum of 2, 3 & 4 indoor units, optimizing use of outdoor space and enhancing exterior aesthetics.

    Regarding new MXZ-2A, a significant reduction was marked both in the size and the weight thus facilitating installation work.

    Single Compact Outdoor Unit Saves Space

    The key to attractive installation and optimum indoor dimension use. Select the best suited model from 12 types covering 6 capacity ranges: 4 types of wall mounted, 4 types of ceiling concealed, 2 x 2 ceiling cassette, Power Cassette,Compact floor standing and ceiling suspended models.

    Select from Wide Range of Indoor UnitsChoose from 12 Types

    Silent Operation

    Easy Installation

    System ImageFeatures of the Branch Box

    Outdoor Installation

    Indoor Installation

    Using the optional cover allows you to install the branch box outdoors. There is no need for a maintenance hole in your ceiling.

    The branch box can be installed inside above the ceiling.By only removing the side and bottom covers, you can access the inner parts like the circuit board providing a great convenience in servicing.

    Noise Kept to a Minimum The branch box houses the linear expansion valve (LEV), a valve which coordinates the flow of refrigerant and tends to produce a certain amount of noise. Since the branch box can be positioned in the ceiling or outdoors, it keeps the noise inevitably generated by the linear expansion valve away from living spaces, allowing a comforting silence to prevail.

    Wall Mounted – DeluxeMSZ-FA

    Wall Mounted – StandardMSZ-GA /GB

    Compact Floor StandingMFZ-FA

    Ceiling Cassette – 600 x 600mmSLZ-KA

    Ceiling Cassette – Power CassettePLA-RP

    Ceiling Concealed – CompactSEZ-KC /KA

    Ceiling ConcealedPEAD-RP EA

    Ceiling Concealed – Thin TypePEAD-RP GA

    2.2kW 2.5kW 3.5kW 5.0kW 6.0kW 7.1kW

    SELECTABLE INDOOR MODELS

    Wall Mounted – DeluxeMSZ-FA

    Wall Mounted – StandardMSZ-GA/GB

    Wall Mounted – StandardMSZ-CB

    Compact Floor StandingMFZ-FA

    Ceiling Cassette – 600 x 600mmSLZ-KA

    Ceiling Cassette – Power CassettePLA-RP

    Ceiling Concealed – CompactSEZ-KC/KA

    Ceiling ConcealedPEAD-RP EA

    Ceiling Concealed – Thin TypePEAD-RP GA

    Ceiling SuspendedPCA-RP

    2.2kW 2.5kW 3.5kW 5.0kW 6.0kW 7.1kW

    SELECTABLE INDOOR MODELS

    PAC-AK50BC

    PAC-AK50BC

    MXZ-8A140VAPAC-AK50BC

    DCInverter

    EER

    ACOP

    APower Multi MXZ-8A140VADC

    Inverter

    EER

    ACOP

    ASmaller MXZ 2, 3 and 4 ports

    Silent Operating Sound,the Top class in the Industry

    Operable under Low OutdoorTemperature

    Function to Fix Operation Mode

    Upgraded Installtion Ability

    The industry top class silent operation of the indoor and outdoor units neither hinder your comfort nor bother your neighbour. Setting the outdoor unit to the Silent Mode reduces the operating sound by 3~4dB further.

    Both cooling and heating operation are possible even in winter with an outdoor temperature of -10°C. Cooling may be useful in pubs and the like crowded in heated atmosphere even in winter.

    Fixing of operation mode can prevent operating in an erroneous mode. Especially convenient in places where many people gather such as in hotels.

    Flexibility in selecting installation spaces is upgraded by extending the total piping length to 30~70m, and the height difference to 15m.*Reuse of existing piping free of cleaning and outdoor unit power supply minimize installation time required.* Reduced to 10m when installing outdoor unit higher than indoor unit* MXZ-4A80VA : 10m

    MXZ-4A80VA

    MSZ-FA

    MFZ-FA

    SEZ-KA

    SLZ-KA

    System Image (example of MXZ-4A80VA system)

    GB

    * *

    KC

    Flexible Choice of Indoor unitThe Power Multi satisfies all your needs. You can choose an indoor unit optimum for the application, interior and size of your room from the versatile product line of 27 models in 10 types.

    Brazing Free Quick InstallationAll the pipings leading to and from the branch box is connected by way of flare joints. Flare joints are easy to use and connect pipes quickly.

    *MXZ-3A54 in cooling (Silent) mode

    GB

    MXZ-2A40/2A52VA MXZ-4A80VAMXZ-3A54/4A71VA

    2port 3port 4port 4port

    indoor 21dB(MSZ-FA/GA25)outdoor 43dB*

    23 24

    *MSZ-CB: only for MXZ-2A/3ANOTE: (1) MXZ-2A : Indoor units up to 3.5kW size can be connected. (2) MXZ-3A54 : Indoor units up to 5.0kW size can be connected.

    (3) MXZ-4A71 : Indoor units up to 6.0kW size can be connected. (Except for PEAD-RP60GA)(4) MXZ-4A80 : Indoor units up to 7.1kW size can be connected.

    *The maximum possible piping length/height differ among each model.

    **

    *

  • 25

    DCInverter

    PAMControl

    EER

    ACOP

    A

    Econo CoolAREA

    Only

    21dBSWING

    HORIZONTAL

    SWINGHORIZONTAL

    SWING

    VERTICAL

    AUTOVANE

    Wide Long

    VERTICALAIR FLOW

    Anti-AllergyEnzyme Catechin

    Fresh Air Intake

    Anti-Mold Air-Cleaning

    Deodorizing

    Auto Panel Flat Panel

    270mm

    Compact

    GlossyWhite

    2x2Size

    Compact

    Cooling at

    -10̊CHeating at

    -20̊C

    i save

    Auto Restart

    Cooling at

    46 C̊/-10 C̊

    24-hour Timer

    ACO

    WeeklyTimer

    CentralizedOn/Off M-NETconnection

    Heating at

    -10̊C

    Quick Clean

    EasyInstallation

    with Leveling Plate

    MXZconnection SelfDiagnosis

    FaliureRecall

    Flareconnection 20m

    12m

    72patterns

    Hot Start

    4 notch 2 notchHighCeiling

    Quiet

    Lossnayconnection

    Long Life Check!High efficiency

    I FEEL

    COMPOGroupControl

    DrainLift UP

    75m

    IN/OUTPower Supply

    Anti moldDP

    120m

    WiringReuse

    EasyMaintenance

    Handycorner pocket

    IconsEnergy Saving

    Comfort

    Fresh Air

    DC Inverter PAM control

    Econo CoolAREA settingi-see Sensor

    EER A

    'I FEEL' Control

    COP A

    Super Quiet : Only 21 dB Auto Vane

    Wide & Long AirflowSwing (vertical vane) Swing (horizontal vane)

    Vertical Air flow

    High Ceilling Air Flow Setting 72 Patterns Air Flow 2 Notch Fan Speed

    Hot Start

    Quiet operation

    4 Notch Fan Speed

    Plasma Duo Filter Systems

    Air Cleaning FilterAnti-Mold Air Cleaning FilterCatechin Filter

    Fresh Air Intake

    Anti-Allergy Enzyme Filter

    Lossnay Connectable

    Long Life Filter High Efficiency Filter (Option) Filter Check SignalDeodorizing Filter

    Design

    Auto Front Panel

    Suitable for 2 x 2 Ceiling(600 x 600mm)

    Flat Panel Glossy Pure White Only 270mm in Height

    Compact Size

    Convenience

    24-hour Timer

    Wide Cooling Temperature Range

    i save Mode

    Auto Change Over

    Weekly Timer (8 patterns/day×7 days)

    Centralized On/Off Control M-NET Connection

    Heating at -20˚C is possible

    Auto Restart

    New PAR-21MAA Connectable

    Heating at -10˚C is possible

    System (Group) Control is possible

    Easy Maintenance Function

    Simultaneous MultipleUnit Operation

    Low Temperature Cooling

    Installation & Maintenance

    Quick Clean Body

    Cleaning Free Pipe Reuse Easy Installationwith an Installation Plate

    Self-Diagnosis Function

    In/Out Separate Power SupplyReuse of Existing Wiring

    MXZ Connectable Failure Recall Function

    Corner Pocket for Maintenance Drain Water Lift Up Pump

    120M Pipe Run 75M Pipe RunEasy & Simple Flare Connection

    Anti Mold Drain Pan

    Long-Length Piping

    Mseries

    26

  • 27

    Wall mounted Type Specifications

    HEAT PUMP

    Type

    Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]

    MSZ-FA25VA

    MSZ-FA25VAMUZ-FA25VA

    2.50.9 - 3.2

    0.5954.20

    A21 - 29 - 36 - 42

    464.2 - 9.9

    3.20.9 - 5.0

    0.7354.35

    A21 - 29 - 36 - 42

    464.4 - 10.2

    6.533

    29878019810

    55080028533

    6.35 / 9.5220 / 12

    -10 ~ +46-10 ~ +24

    MSZ-FA25VAH

    MSZ-FA25VAMUZ-FA25VAH

    2.50.9 - 3.2

    0.5954.20

    A21 - 29 - 36 - 42

    464.2 - 9.9

    3.20.9 - 5.0

    0.7354.35

    A21 - 29 - 36 - 42

    464.4 - 10.2

    6.5332987801981055080028533

    6.35 / 9.5220 / 12

    -10 ~ +46-20 ~ +24

    MSZ-FA35VA

    MSZ-FA35VAMUZ-FA35VA

    3.51.0 - 4.1

    0.9353.74

    A22 - 29 - 36 - 42

    474.3 - 9.9

    4.00.9 - 6.0

    0.9954.02

    A22 - 29 - 36 - 42

    484.6 - 10.2

    9.5332987801981055080028537

    6.35 / 9.5220 / 12

    -10 ~ +46-10 ~ +24

    MSZ-FA35VAH

    MSZ-FA35VAMUZ-FA35VAH

    3.51.0 - 4.1

    0.9353.74

    A22 - 29 - 36 - 42

    474.3 - 9.9

    4.00.9 - 6.00.9954.02

    A22 - 29 - 36 - 42

    484.6 - 10.2

    9.5332987801981055080028537

    6.35 / 9.5220 / 12

    -10 ~ +46-20 ~ +24

    Inverter Heat Pump

    MSZ-FAseries

    Cooling

    Heating

    Max. Running Current

    Indoor

    Outdoor

    Ext. Piping

    Guaranteed Operating Range

    [Outdoor]

    Capacity

    Total Input

    EER

    SPL

    Air Volume

    Capacity

    Total Input

    COP

    SPL

    Air Volume

    Input

    Dimensions

    Weight

    Dimensions

    Weight

    Diameter

    Max. Length / Max. Height

    RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High-SHi]*1

    OUTIN [Low-SHi]*1

    RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High-SHi]*1

    OUTIN [Low-SHi]*1

    RatedHeightWidthDepth

    HeightWidthDepth

    Liquid / Gas (φ)

    CoolingHeating*1SHi: Super High

    kWkWkW

    dB(A) dB(A)m3/minkWkWkW

    dB(A)dB(A)m3/min

    AW

    mmmmmmkg

    mmmmmmkg

    mmmoCoC

    230, Single, 50, outdoor power supply

    EER

    ACOP

    A

    Outdoor Unit

    Indoor Unit

    RemoteController

    MXZconnection

    DCInverter

    PAMControl Econo Cool

    AUTOVANE Auto Panel Flat Panel

    Auto Restart

    Cooling at

    46 C̊/-10 C̊

    Quick CleanSelf

    Diagnosis

    FaliureRecall

    Flareconnection20m

    12m

    AREAArea setting

    GlossyWhite

    24-hour Timer

    ACO

    SWING

    HORIZONTAL

    SWING

    VERTICAL

    WeeklyTimerOptional

    CentralizedOn/Off

    Optional

    M-NETconnection

    Optional

    Only

    21dBFA25

    Heating at

    -10̊COptional

    Compact

    Anti-Mold

    VA

    VAH

    Heating at

    -20̊C

    28

    Wall mounted Type Specifications

    HEAT PUMP

    Type

    Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]

    MSZ-GA22VA

    MSZ-GA22VAN/A*2

    -

    -------

    -----

    0.333

    298780210

    9----

    6.35 / 9.52---

    MSZ-GA25VA

    MSZ-GA25VAMUZ-GA25VA

    2.50.9 - 3.0

    0.643.91

    A21 - 29 - 36 - 43

    463.9 - 10.0

    3.20.9 - 4.5

    0.764.21

    A21 - 29 - 36 - 43

    464.3 - 10.5

    5.533

    298780210

    955080028531

    6.35 / 9.5220 / 12

    -10 ~ +46-10 ~ +24

    MSZ-GA25VAH

    MSZ-GA25VAMUZ-GA25VAH

    2.50.9 - 3.0

    0.643.91

    A21 - 29 - 36 - 43

    463.9 - 10.0

    3.20.9 - 4.5

    0.764.21

    A21 - 29 - 36 - 43

    464.3 - 10.5

    5.533

    298780210

    955080028531

    6.35 / 9.5220 / 12

    -10 ~ +46-20 ~ +24

    MSZ-GA35VA

    MSZ-GA35VAMUZ-GA35VA

    3.51.0 - 3.9

    1.083.24

    A22 - 29 - 36 - 43

    474.1 - 10.0

    4.00.9 - 5.0

    1.0553.79

    A22 - 29 - 36 - 43

    484.5 - 10.5

    6.533

    298780210

    955080028533

    6.35 / 9.5220 / 12

    -10 ~ +46-10 ~ +24

    MSZ-GA35VAH

    MSZ-GA35VAMUZ-GA35VAH

    3.51.0 - 3.9

    1.083.24

    A22 - 29 - 36 - 43

    474.1 - 10.0

    4.00.9 - 5.0

    1.0553.79

    A22 - 29 - 36 - 43

    484.5 - 10.5

    6.533

    298780210

    955080028533

    6.35 / 9.5220 / 12

    -10 ~ +46-20 ~ +24

    Inverter Heat Pump

    MSZ-GAseries

    Cooling

    Heating

    Max. Running Current

    Indoor

    Outdoor

    Ext. Piping

    Guaranteed Operating Range

    [Outdoor]

    Capacity

    Total Input

    EER

    SPL

    Air Volume

    Capacity

    Total Input

    COP

    SPL

    Air Volume

    Input

    Dimensions

    Weight

    Dimensions

    Weight

    Diameter

    Max. Length / Max. Height

    RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High-SHi]*1

    OUTIN [Low-SHi]*1

    RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High-SHi]*1

    OUTIN [Low-SHi]*1

    RatedHeightWidthDepth

    HeightWidthDepth

    Liquid / Gas (φ)

    CoolingHeating*1SHi: Super High*2MSZ-GA22VA is for MXZ connection only.

    kWkWkW

    dB(A)dB(A)m3/minkWkWkW

    dB(A)dB(A)m3/min

    AW

    mmmmmmkg

    mmmmmmkg

    mmmoCoC

    230, Single, 50, outdoor power supply

    EER

    ACOP

    A

    Outdoor Unit

    Indoor Unit

    RemoteController

    MXZconnection

    DCInverter

    PAMControl Econo Cool

    AUTOVANE Flat Panel

    Auto Restart

    Cooling at

    46 C̊/-10 C̊ Quick Clean

    SelfDiagnosis

    FaliureRecall

    Flareconnection20m

    12m

    GlossyWhite

    24-hour Timer

    ACO

    SWING

    HORIZONTAL

    WeeklyTimerOptional

    CentralizedOn/Off

    Optional

    M-NETconnection

    Optional

    Only

    21dBGA25

    Heating at

    -10̊COptional

    Catechinas Standard filter Optional

    Anti-AllergyEnzyme Compact

    VA VAH

    Heating at

    -20̊C

  • Wall mounted Type Specifications

    HEAT PUMP

    Type

    Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]

    MSZ-GB50VA

    MSZ-GB50VAMUZ-GB50VA

    5.00.9 - 5.8

    1.6503.03

    B32 - 38 - 44 - 48(SHi)*

    526.9 - 10.9(SHi)*

    5.80.9 - 7.8

    1.703.41

    B30 - 36 - 42 - 48 (SHi)*

    556.9 - 10.9 (SHi)*

    1640298780210

    985084033053

    6.35 / 12.730 / 15

    -10 ~ +43-10 ~ +24

    MSZ-GA60VA

    MSZ-GA60VAMUZ-GA60VA

    6.00.9 - 6.7

    1.933.11

    B32 - 40 - 54

    538.7 - 17.2

    6.80.9 - 8.1

    1.943.51

    B32 - 40 - 54

    558.7 - 17.2

    1660325

    1,1002581685084033053

    6.35 / 15.8830 / 15

    -10 ~ +43-10 ~ +24

    MSZ-GA71VA

    MSZ-GA71VAMUZ-GA71VA

    7.10.9 - 8.3

    2.422.93

    C33 - 40 - 54

    539.4 - 17.2

    8.10.9 - 9.6

    2.453.31

    C33 - 40 - 54

    559.4 - 17.2

    1660325

    1,1002581685084033058

    9.52 / 15.8830 / 15

    -10 ~ +43-10 ~ +24

    Inverter Heat Pump

    MSZ-GA/GBseries

    Cooling

    Heating

    Max. Running Current

    Indoor

    Outdoor

    Ext. Piping

    Guaranteed Operating Range

    [Outdoor]

    Capacity

    Total Input

    EER

    SPL

    Air Volume

    Capacity

    Total Input

    COP

    SPL

    Air Volume

    Input

    Dimensions

    Weight

    Dimensions

    Weight

    Diameter

    Max. Length / Max. Height

    RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High]OUTIN [Low-High]RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High]OUTIN [Low-High]

    RatedHeightWidthDepth

    HeightWidthDepth

    Liquid / Gas (φ)

    CoolingHeating

    kWkWkW

    dB(A)dB(A)m3/minkWkWkW

    dB(A)dB(A)m3/min

    AW

    mmmmmmkg

    mmmmmmkg

    mmmoCoC

    230, Single, 50, outdoor power supply

    Outdoor Unit

    Indoor Unit

    RemoteController

    29

    * SHi: Super High

    MXZconnection

    FaliureRecall

    Flareconnection30m

    15m

    SWING

    GA60/71

    DCInverter

    PAMControl Econo Cool

    AUTOVANE Flat Panel

    SWING

    HORIZONTAL GA60/71 GA60/71

    Catechinas Standard filter Optional GB50

    Anti-AllergyEnzymeWide Long

    Auto RestartSelf

    Diagnosis

    GlossyWhite

    24-hour TimerGB50

    ACOWeekly

    TimerOptional

    CentralizedOn/Off

    Optional

    M-NETconnection

    OptionalOptional

    Cooling at

    -10̊CHeating at

    -10̊C

    MSZ-GB50

    MSZ-GA60/71

    30

    Wall mounted Type Specifications

    HEAT PUMP

    Type

    Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]

    MSZ-HA25VA

    MSZ-HA25VAMUZ-HA25VA

    2.50.9 - 3.0

    0.7853.18

    B26 - 43

    465.3 - 10.5

    3.20.9 - 4.4

    0.9453.39

    C26 - 43

    465.1 - 11.0

    5.523

    295788225

    955080028531

    6.35 / 9.5210 / 5

    +18 ~ +43-10 ~ +24

    MSZ-HA35VA

    MSZ-HA35VAMUZ-HA35VA

    3.151.0 - 3.7

    1.0453.01

    B26 - 43

    475.3 - 10.5

    3.60.9 - 4.8

    1.073.36

    C26 - 43

    485.1 - 11.0

    6.523

    295788225

    955080028533

    6.35 / 9.5210 / 5

    +18 ~ +43-10 ~ +24

    Inverter Heat Pump

    MSZ-HAseries

    Cooling

    Heating

    Max. Running Current

    Indoor

    Outdoor

    Ext. Piping

    Guaranteed Operating Range

    [Outdoor]

    Capacity

    Total Input

    EER

    SPL

    Air Volume

    Capacity

    Total Input

    COP

    SPL

    Air Volume

    Input

    Dimensions

    Weight

    Dimensions

    Weight

    Diameter

    Max. Length / Max. Height

    RatedMin - MaxRated

    EEL Rank

    IN [Low-SHi]OUTIN [Low-SHi]RatedMin - MaxRated

    EEL Rank

    IN [Low-SHi]OUTIN [Low-SHi]

    RatedHeightWidthDepth

    HeightWidthDepth

    Liquid / Gas

    CoolingHeating

    kWkWkW

    dB(A)dB(A)m3/minkWkWkW

    dB(A)dB(A)m3/min

    AW

    mmmmmmkg

    mmmmmmkg

    mmmoCoC

    230, Single, 50, outdoor power supply

    Outdoor Unit

    Indoor Unit

    RemoteController

    * SHi : Super High

    DCInverter Econo Cool

    AUTOVANE Flat Panel

    Flareconnection10m

    5m

    Only

    26dBHeating at

    -10̊CCatechinOptionalHORIZONTAL HORIZONTAL

    CompactVA12-hour Timer

    12

    SWING GlossyWhite

  • Wall mounted Type Specifications

    HEAT PUMP

    Type

    Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]

    MSH-GA20VB

    MSC-GA20VBMUH-GA20VB

    2.3-

    0.7153.22

    A25 - 31 - 36

    477.92.5

    -0.693.62

    A25 - 31 - 36

    478.55.735

    278815244

    955080028529

    6.35 / 9.5220 / 10

    +21 ~ +43-10 ~ +24

    MSH-GA25VB

    MSC-GA25VBMUH-GA25VB

    2.65-

    0.823.23

    A25 - 31 - 36

    497.93.0

    -0.823.66

    A25 - 32 - 39

    499.86.135

    278815244

    955080028530

    6.35 / 9.5220 / 10

    +21 ~ +43-10 ~ +24

    MSH-GA35VB

    MSC-GA35VBMUH-GA35VB

    3.5-

    1.093.21

    A26 - 33 - 40

    499.73.7

    -1.023.63

    A26 - 33 - 39

    4910.17.740

    27881524410

    55080028535

    6.35 / 9.5225 / 10

    +21 ~ +43-10 ~ +24

    Fixed-Speed Heat Pump

    MSH-GAseries

    Cooling

    Heating

    Max. Running Current

    Indoor

    Outdoor

    Ext. Piping

    Guaranteed Operating Range

    [Outdoor]

    Capacity

    Total Input

    EER

    SPL

    Air Volume

    Capacity

    Total Input

    COP

    SPL

    Air Volume

    Input

    Dimensions

    Weight

    Dimensions

    Weight

    Diameter

    Max. Length / Max. Height

    RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High]OUTIN [High]RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High]OUTIN [High]

    RatedHeightWidthDepth

    HeightWidthDepth

    Liquid / Gas (φ)

    CoolingHeating

    kWkWkW

    dB(A)dB(A)m3/minkWkWkW

    dB(A)dB(A)m3/min

    AW

    mmmmmmkg

    mmmmmmkg

    mmmoCoC

    230, Single, 50, indoor/outdoor separate power supply

    COP

    AEER

    A

    32

    SelfDiagnosis

    MXZconnection

    Flareconnection

    MXZ-A14/18WV

    20m10m

    GA20/25

    25m10m

    GA35

    Econo CoolAUTOVANE Auto Restart

    GlossyWhite

    24-hour Timer

    SWING

    HORIZONTAL

    I FEEL

    Flat PanelCompact

    Catechinas Standard filter

    Air-CleaningOptional

    Outdoor Unit

    Indoor Unit

    RemoteController

    Wall mounted Type Specifications

    HEAT PUMP

    Type

    Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]

    MSZ-CB22VA

    MSZ-CB22VAN/A*2

    -

    -------

    -----

    0.333298780210

    9----

    6.35 / 9.52---

    MSZ-CB35VA

    MSZ-CB35VAMUZ-GA35VA

    3.51.0 - 3.9

    1.083.24

    A22 - 29 - 36 - 43

    474.1 - 10.0

    4.00.9 - 5.0

    1.0553.79

    A22 - 29 - 36 - 43

    484.5 - 10.5

    6.533298780210

    955080028533

    6.35 / 9.5220 / 12

    -10 ~ +46-10 ~ +24

    Inverter Heat Pump

    MSZ-CBseries

    Cooling

    Heating

    Max. Running Current

    Indoor

    Outdoor

    Ext. Piping

    Guaranteed Operating Range

    [Outdoor]

    Capacity

    Total Input

    EER

    SPL

    Air Volume

    Capacity

    Total Input

    COP

    SPL

    Air Volume

    Input

    Dimensions

    Weight

    Dimensions

    Weight

    Diameter

    Max. Length / Max. Height

    RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High-SHi*1]OUTIN [Low-SHi*1]RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High-SHi*1]OUTIN [Low-SHi*1]

    RatedHeightWidthDepth

    HeightWidthDepth

    Liquid / Gas (φ)

    CoolingHeating

    kWkWkW

    dB(A)dB(A)m3/minkWkWkW

    dB(A)dB(A)m3/min

    AW

    mmmmmmkg

    mmmmmmkg

    mmmoCoC *1SHi: Super High *2MSZ-CB22VA is for MXZ connection only.

    230, Single, 50, outdoor power supply

    EER

    ACOP

    A

    31

    MSZ-CB25VA

    MSZ-CB25VAMUZ-GA25VA

    2.50.9 - 3.0

    0.643.91

    A21 - 29 - 36 - 43

    463.9 - 10.0

    3.20.9 - 4.5

    0.764.21

    A21 - 29 - 36 -43

    464.3 - 10.5

    5.533298780210

    955080028531

    6.35 / 9.5220 / 12

    -10 ~ +46-10 ~ +24

    MXZconnection

    DCInverter

    PAMControl Econo Cool

    AUTOVANE Flat Panel

    Auto Restart

    Cooling at

    46 C̊/-10 C̊ Quick Clean SelfDiagnosis

    FaliureRecall

    Flareconnection20m

    12m

    GlossyWhite

    24-hour Timer

    ACO

    SWING

    HORIZONTAL

    WeeklyTimerOptional

    CentralizedOn/Off

    Optional

    M-NETconnection

    Optional

    Only

    21dBCB25

    Heating at

    -10̊COptional

    Catechinas Standard filter Optional

    Anti-AllergyEnzyme Compact

    Outdoor Unit

    Indoor Unit

    RemoteController

  • Wall mounted Type Specifications

    Cooling Only

    Type

    Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]

    MS-GA20VB

    MSC-GA20VBMU-GA20VB

    2.3-

    0.7153.22

    A25 - 31 - 36

    457.9

    --------

    5.735

    278815244

    955080028527

    6.35 / 9.5220 / 10

    +21 ~ +43-

    MS-GA25VB

    MSC-GA25VBMU-GA25VB

    2.5-

    0.7753.23

    A25 - 31 - 36

    457.9

    --------

    5.635

    278815244

    955080028527

    6.35 / 9.5220 / 10

    +21 ~ +43-

    MS-GA35VB

    MSC-GA35VBMU-GA35VB

    3.45-

    1.123.08

    B26 - 33 - 40

    499.7

    --------

    8.340

    27881524410

    55080028530

    6.35 / 9.5225 / 10

    +21 ~ +43-

    Fixed-Speed Cooling Only

    MS-GAseries

    Cooling

    Heating

    Max. Running Current

    Indoor

    Outdoor

    Ext. Piping

    Guaranteed Operating Range

    [Outdoor]

    Capacity

    Total Input

    EER

    SPL

    Air Volume

    Capacity

    Total Input

    COP

    SPL

    Air Volume

    Input

    Dimensions

    Weight

    Dimensions

    Weight

    Diameter

    Max. Length / Max. Height

    RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High]OUTIN [High]RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High]OUTIN [High]

    RatedHeightWidthDepth

    HeightWidthDepth

    Liquid / Gas (φ)

    CoolingHeating

    kWkWkW

    dB(A)dB(A)m3/minkWkWkW

    dB(A)dB(A)m3/min

    AW

    mmmmmmkg

    mmmmmmkg

    mmmoCoC

    230, Single, 50, indoor/outdoor separate power supply

    EER

    AGA20/25

    34

    SelfDiagnosis

    MXZconnection

    Flareconnection

    MXZ-A14/18WV

    20m10m

    GA20/25

    25m10m

    GA35

    Catechinas Standard filter

    Econo CoolAUTOVANE Auto Restart

    GlossyWhite

    24-hour Timer

    SWING

    HORIZONTAL

    I FEEL

    Air-CleaningOptional

    Flat PanelCompact

    Outdoor Unit

    Indoor Unit

    RemoteController

    Wall mounted Type Specifications

    HEAT PUMP

    Type

    Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]

    MSH-GA50VB

    MSH-GA50VBMUH-GA50VB

    5.0-

    1.782.81

    C34 - 38 - 42

    5212.85.2

    -1.613.23

    C34 - 38 - 42

    5212.812.960325

    1,1002581660585029047

    6.35 / 12.725 / 10

    +21 ~ +43-10 ~ +24

    MSH-GA60VB

    MSH-GA60VBMUH-GA60VB

    6.3-

    2.412.61

    D37 - 41 - 45

    5312.87.2

    -2.482.90

    D34 - 41 - 45

    5312.816.560325

    1,1002581685084033074

    6.35 / 15.8825 / 10

    +21 ~ +43-10 ~ +24

    MSH-GA80VB

    MSH-GA80VBMUH-GA80VB

    8.5-

    3.262.61

    D37 - 42 - 47

    5515.99.4

    -3.432.74

    E37 - 42 - 47

    5515.922.969325

    1,1002581685084033077

    9.52 / 15.8830 / 15

    +21 ~ +43-10 ~ +24

    Fixed-Speed Heat Pump

    MSH-GAseries

    Cooling

    Heating

    Max. Running Current

    Indoor

    Outdoor

    Ext. Piping

    Guaranteed Operating Range

    [Outdoor]

    Capacity

    Total Input

    EER

    SPL

    Air Volume

    Capacity

    Total Input

    COP

    SPL

    Air Volume

    Input

    Dimensions

    Weight

    Dimensions

    Weight

    Diameter

    Max. Length / Max. Height

    RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High]OUTIN [High]RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High]OUTIN [High]

    RatedHeightWidthDepth

    HeightWidthDepth

    Liquid / Gas (φ)

    CoolingHeating

    kWkWkW

    dB(A)dB(A)m3/minkWkWkW

    dB(A)dB(A)m3/min

    AW

    mmmmmmkg

    mmmmmmkg

    mmmoCoC

    230, Single, 50, indoor/outdoor separate power supply

    MUH-GA50VB MUH-GA60/80VB

    33

    Catechinas Standard filter

    Econo Cool

    Auto RestartSelf

    Diagnosis

    Flareconnection

    GlossyWhite

    24-hour Timer

    I FEEL

    Air-CleaningOptional

    Flat Panel

    25m10m

    GA50/60

    30m15m

    GA80

    AUTOVANE

    SWING

    HORIZONTAL

    SWING

    VERTICAL

    Wide Long

    Outdoor Unit

    Indoor Unit

    RemoteController

  • Wall mounted Type Specifications

    HEAT PUMP

    Type

    Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]

    MSH-CB20VB

    MSC-CB20VBMUH-GA20VB

    2.3-

    0.7153.22

    A25 - 31 - 36

    477.92.5

    -0.693.62

    A25 - 31 - 36

    478.55.735

    278815244

    955080028529

    6.35 / 9.5220 / 10

    +21 ~ +43-10 ~ +24

    MSH-CB25VB

    MSC-CB25VBMUH-GA25VB

    2.65-

    0.823.23

    A25 - 31 - 36

    497.93.0

    -0.823.66

    A25 - 32 - 39

    499.86.135

    278815244

    955080028530

    6.35 / 9.5220 / 10

    +21 ~ +43-10 ~ +24

    MSH-CB35VB

    MSC-CB35VBMUH-GA35VB

    3.5-

    1.093.21

    A26 - 33 - 40

    499.73.7

    -1.023.63

    A26 - 33 - 39

    4910.17.740

    27881524410

    55080028535

    6.35 / 9.5225 / 10

    +21 ~ +43-10 ~ +24

    MSH-CB50VB

    MSH-CB50VBMUH-GA50VB

    5.0-

    1.782.81

    C34 - 38 - 42

    5212.85.2

    -1.613.23

    C34 - 38 - 42

    5212.812.960

    3251,10025816

    60585029047

    6.35 / 12.725 / 10

    +21 ~ +43-10 ~ +24

    Fixed-Speed Heat Pump

    MSH-CBseries

    Cooling

    Heating

    Max. Running Current

    Indoor

    Outdoor

    Ext. Piping

    Guaranteed Operating Range

    [Outdoor]

    Capacity

    Total Input

    EER

    SPL

    Air Volume

    Capacity

    Total Input

    COP

    SPL

    Air Volume

    Input

    Dimensions

    Weight

    Dimensions

    Weight

    Diameter

    Max. Length / Max. Height

    RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High]OUTIN [High]RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High]OUTIN [High]

    RatedHeightWidthDepth

    HeightWidthDepth

    Liquid / Gas (φ)

    CoolingHeating

    kWkWkW

    dB(A)dB(A)m3/minkWkWkW

    dB(A)dB(A)m3/min

    AW

    mmmmmmkg

    mmmmmmkg

    mmmoCoC

    230, Single, 50, indoor/outdoor separate power supply

    MUH-GA20/25/35VB MUH-GA50VB

    EER

    ACB20/25/35

    COP

    ACB20/25/35

    36

    SelfDiagnosis

    MXZconnection

    Flareconnection

    MXZ-A14/18WV

    20m10m

    GA20/25

    25m10m

    GA35

    Catechinas Standard filter

    Econo CoolAUTOVANE Auto Restart

    GlossyWhite

    24-hour Timer

    SWING

    HORIZONTAL

    I FEEL

    Air-CleaningOptional

    Flat PanelCompact

    Outdoor Unit

    Indoor Unit

    RemoteController

    MSH-CB20/25/35VB

    MSH-CB50VB

    Wall mounted Type Specifications

    Type

    Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]

    MS-GA50VB

    MS-GA50VBMU-GA50VB

    5.0-

    1.812.76

    D34 - 38 - 42

    5212.8

    --------

    13.260325

    1,1002581660585029044

    6.35 / 12.725 / 10

    +21 ~ +43-

    MS-GA60VB

    MS-GA60VBMU-GA60VB

    6.5-

    2.482.62

    D37 - 41 - 45

    5312.8

    --------

    16.960325

    1,1002581660585029060

    6.35 / 15.8825 / 10

    +21 ~ +43-

    MS-GA80VB

    MS-GA80VBMU-GA80VB

    8.5-

    3.262.61

    D37 - 42 - 47

    5515.9

    --------

    22.669325

    1,1002581685084033075

    9.52 / 15.8830 / 15

    +21 ~ +43-

    Fixed-Speed Cooling Only

    MS-GAseries

    Cooling

    Heating

    Max. Running Current

    Indoor

    Outdoor

    Ext. Piping

    Guaranteed Operating Range

    [Outdoor]

    Capacity

    Total Input

    EER

    SPL

    Air Volume

    Capacity

    Total Input

    COP

    SPL

    Air Volume

    Input

    Dimensions

    Weight

    Dimensions

    Weight

    Diameter

    Max. Length / Max. Height

    RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High]OUTIN [High]RatedMin - MaxRated

    EEL Rank

    IN [Low-Mid-High]OUTIN [High]

    RatedHeightWidthDepth

    HeightWidthDepth

    Liquid / Gas (φ)

    CoolingHeating

    kWkWkW

    dB(A)dB(A)m3/minkWkWkW

    dB(A)dB(A)m3/min

    AW

    mmmmmmkg

    mmmmmmkg

    mmmoCoC

    230, Single, 50, indoor/outdoor separate power supply

    Cooling Only

    MU-GA50/60VB MU-GA80VB

    35

    Auto RestartSelf

    Diagnosis

    Flareconnection

    24-hour Timer

    25m10m

    GA50/60

    30m15m

    GA80

    Catechinas Standard filter

    Econo CoolAUTOVANE

    GlossyWhite

    SWING

    HORIZONTAL

    I FEEL

    Air-CleaningOptional

    Flat Panel

    SWING

    VERTICAL

    Wide Long

    Outdoor Unit

    Indoor Unit

    RemoteController

  • Two-way Floor Standing and Ceiling suspended Type Specifications

    HEAT PUMP

    Type

    Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]

    MCFH-GA35VB

    MCFH-GA35VBM