New publication effective Aug. 2006Specifications subuject to change without noticeL-179-5-C6975-D SI 0608
HEAD OFFICE: TOKYO BLDG.,2-7-3, MARUNOUCHI,CHIYODA-KU, TOKYO 100-8310, JAPANhttp://Global.MitsubishiElectric.com/
2006
-
M Series
S Series
P Series
Multi System
Line Up
Mitsubishi Electric's Main Technology
High End Models
Icons
3-6
7-14
15-24
25
26-39
40-42
43-73
74-90
C O N T E N T S
Mitsubishi Electric,s Long history proves excellence in air conditioning with the leading-edge technology.With 50 years experience in developing air conditioner, Mitsubishi Electric's cost effective ,
energy conscious systems are expertly designed to provide you with constant ,
comfortable living and working environments.
-
P75
P77
P77
P77
P77
P77
P87
P87
P87
P87
P87
P87
Wall Mounted Ceiling SuspendedFloor Standing Ceiling ConcealedCassette
■INVERTER Models ●Heat Pump type
■FIXED-SPEED Models ●Cooling Only type
MXZ-8A140VA
Multi Series
up to 8indoor units
14.0kW
MXZ-4A80VA
up to 4indoor units
8.0kW
MXZ-4A71VA
up to 4indoor units
7.1kW
MXZ-3A54VA
up to 3indoor units
5.4kW
MXZ-2A52VA
up to 2indoor units
5.2kW
MXZ-2A40VA
up to 2indoor units
4.0kW
MUX-4A73VB
up to 4indoor units
7.3kW
MUX-3A63VB
up to 3indoor units
6.3kW
MUX-3A60VB
up to 3indoor units
6.0kW
MUX-2A70VB
up to 2indoor units
7.0kW
MUX-2A59VB
up to 2indoor units
5.9kW
MUX-2A28VB
up to 2indoor units
2.8kW
MSZ-FA25/35MSZ-GA22/25/35
MSZ-GB50, GA60/71
MSZ-FA25/35MSZ-GA22/25/35
MSZ-GB50, GA60/71
MSZ-FA25/35MSZ-GA22/25/35MSZ-GB50, GA60
MSZ-FA25/35MSZ-GA22/25/35
MSZ-GB50
MSZ-FA25/35MSZ-GA22/25/35
MSZ-FA25/35MSZ-GA22/25/35
MSC-GA25/35
MSC-GA20/35
MSC-GA25
MSC-GA35
MSC-GA20/35
MSC-GA20
MFZ-KA25/35/50
MFZ-KA25/35/50
MFZ-KA25/35/50
MFZ-KA25/35/50
MFZ-KA25/35
MFZ-KA25/35
SLZ-KA25/35/50PLA-RP35/50/60/71
SLZ-KA25/35/50PLA-RP50/60/71
SLZ-KA25/35/50PLA-RP50/60
SLZ-KA25/35/50PLA-RP50
SLZ-KA25/35
SLZ-KA25/35
SEZ-KC25SEZ-KA35/50/60/71PEAD-RP50/60/71EA
PEAD-RP60/71GA
SEZ-KC25SEZ-KA35/50/60
PEAD-RP50EAPEAD-RP60/71GA
SEZ-KC25SEZ-KA35/50/60
PEAD-RP50EA
SEZ-KC25SEZ-KA35/50PEAD-RP50EA
SEZ-KC25SEZ-KA35
SEZ-KC25SEZ-KA35
PCA-RP50/60/71
PCA-RP50/60
PCA-RP50
4
Line-up
■INVERTER Models ●Heat Pump type
■FIXED-SPEED Models
Wall Mounted
CompactFloor
MSZ-FA series
MSZ-GA/GB series
MSZ-HA series
MFZ-KA series
2.0kW 2.2kW 2.5kW 3.5kW 5.0kW
New Design
6.0kW 7.1kW 8.0kW page
P27
P28
P30
P37
Model Name
2.0kW 2.2kW 2.5kW 3.5kW 5.0kW 6.0kW 7.1kW 8.0kW pageModel Name
Wall Mounted
Two-way Floor / Ceiling
MS(H)-GA series
MSH-CB series
P32
MCF(H)-GA series
P34
P38
P39
■INVERTER Models ●Heat Pump type2.0kW 2.2kW 2.5kW 3.5kW 5.0kW 6.0kW 7.1kW 8.0kW pageModel Name
M series
S series
*
H
H
H
*
MSZ-CB series
P31
2x2Cassette
SLZ-KA series
P41
P36
H
H
H
HeatPump
CoolingOnly
HeatPump
CoolingOnly
HeatPump
CompactCeilingConcealed
SEZ-KC series
SEZ-KA series
P42
P42
3
H:Outdoor unit with anti-freeze heater is available. *Indoor unit only
-
6
■FIXED-SPEED Models
4 way Cassette
Ceiling Concealed
Wall mounted
Ceiling Suspended
Floor Standing PS(H) series
PC(H)-HA series
for Professional Kitchen
PC(H)-GA series
PK(H)-FAL series
PEH series
R407C R407C
PE(H)D-GA series
PE(H)D-EA series
PL(H) series
3HP 4HP 5HP 6HP 8HP 10HP
7.1kW 10.0kW 12.5kW 14.0kW 20.0kW 25.0kWpage
P59
P60
P61
P62
P63
P64
P73
P65
P66
P67
P68
P69
P70
P71
P72
Model Name
P series
HeatPump
CoolingOnly
HeatPump
CoolingOnly
HeatPump
CoolingOnly
HeatPump
HeatPump
CoolingOnly
HeatPump
CoolingOnly
HeatPump
CoolingOnly
HeatPump
CoolingOnly
*Indoor unit with a booster heater is also available.
* * * *
* * * *
* *
* * * *
* * * *
Line-up
5
■POWER INVERTER Models
4 way Cassette
Ceiling Concealed
Ceiling Suspend
Floor Standing
3.5kW
1.6HP 2HP 2.5HP 3HP 4HP 5HP 6HP 8HP 10HP
5.0kW 6.0kW 7.1kW 10.0kW* 12.5kW* 14.0kW* 20.0kW** 25.0kW**page
P44
P45
P46
P47
P48
P48
P49
P50
P51
Model Name
P series
PLZ-RP series
PEDZ-RP EA series
PEDZ-RP GA series
PEZ-RP series
Wall mounted PKZ-RP GAL series
PKZ-RP FAL series
PCZ-RP GA series
PCZ-RP HA seriesforProfessionalKitchen
PSZ-RP series
*3 phase type is also available for 10.0kW,12.5kW and 14.0kW class models.**Only 3 phase type is available for 20.0kW class models.
*1 phase type models Only.
■STANDARD INVERTER Models*
4 way Cassette
Ceiling Concealed
Ceiling Suspend
Wall mounted
3.5kW
1.6HP 2HP 2.5HP 3HP 4HP 5HP 6HP 8HP 10HP
5.0kW 6.0kW 7.1kW 10.0kW 12.5kW 14.0kW 20.0kW 25.0kWpage
P52
P53
P54
P55
P56
P57
P58
Series Name
SPLZ/PLZ-P series
SPEDZ-EA/PEDZ-P EA series
SPEDZ-GA/PEDZ-P GA series
SPCZ/PCZ-P GA series
PCZ-P HA series forProfessionalKitchen
PKZ-P FAL series
Floor Standing PSZ-P series
-
2002JSRAE
TECHNOLOGY AWARD
2002JSRAE
TECHNOLOGY AWARD
Japan Society of Refrigerating and Air Conditioning Engineers
DC compressor motor ( rotor ) Neodymium magnets
The reluctance DC motor has a rotor equipped with powerful neodymium magnets. The magnetic torque produced by the neodymium magnets and reluctance torque results in more efficient operation.
Our unique motor, known as “Poki-Poki Motor“ in Japan, employs joint lap production technique. Originally developed by Mitsubishi Electric, this motor offers high density and high magnetic force leading to high efficiency and high reliability.
Magnetic torque
+Reluctance torque
LEV1
Powerreceiver
Heatexchanger
Heatexchanger
Compressor
LEV2
Mitsubishi Electric has developed a power receiver and twin LEVs (linear expansion valves) that optimise the performance of the compressor. By ensuring optimum control in response to the operating waveform and outdoor temperature, this technology is tailored to the characteristics of the new refrigerant to enhance operating efficiency.
This intelligent temperature control feature — that adjusts airflow interval to the body depending on air outlet temperature — allows set temperatures to be raised by 2 degrees without any loss in comfort for a 20% gain in energy efficiency.
Power Receiver and Twin LEV Control
Joint Lap DC Motor
“Econo Cool” Energy-Saving Feature
Conventional Econo CoolAmbient temperature 35°C 35°CSet temperature 25°C 27°C
temperature 30°C 29.3°C
“Econo Cool” modeEnsures more comfort even when the set temperature is 2°C higher than the conventional cooling mode.
“Econo Cool” On Conventional cooling mode
Thrust gas power: minimum
Cradle scrollFrame
Secondary back-pressure chamber minimizes thrust friction loss.
Primary back-pressure chamber minimizes leakage loss.
Thrust friction loss: minimum
Leakage loss: minimumFixed scroll
The highly efficient scroll com-pressor is equipped with a “Frame Compliance Mechanism” that allows movement in the axial direction of the frame supporting the cradle scroll. This greatly reduces both leakage and friction loss, ensuring very high efficiency throughout the speed range.
Highly Efficient DC Scroll Compressor
Frame movable in the direction
of the axis.
Remarkablereduction
in leakage and friction loss
Without PAM Control With PAM ControlSupplyvoltage
CurrentTime Time
PAM adjusts the form of the current wave so that it becomes close to that of the supply voltage wave. High harmonics are reduced and 98% of the electricity is utilized.
Using a Motorcycle as an example
PAM
Energy savings is limited.Fuel is wasted.
Significant energy savings.Electricity loss reduced for surprising energy savings.
Power is limited.Power is insufficientfor steep hills.
Power increased.Efficient increase of voltage for increased power.
ConventionalInverter
This diagram illustrates the merits of PAM Control.
PAM (Pulse Amplitude Modulation)Electricity can be used efficiently with less loss, if the current wave resembles the supply voltage wave. PAM is a method for controlling the form of the current wave so that it conforms to the supply voltage wave. With PAM control, 98% of input power supply can be effectively used.
Magnetic Flux Vector Sine Wave DriveBy converting the motor’s electrical current waveform from the conventional waveform to a sine wave (180° con-ductance), this microprocessor raises the motor winding utilization ratio and reduces energy loss for higher efficiency.
A high-efficiency DC motor drives the fan of the outdoor unit. It offers up to 60% greater efficiency than an equivalent AC motor.
DC Fan Motor
70%
80%
90%
100%
Eff
icie
ncy
0 2 4 6 8 10 12 14 16
Number of Years in Use
Flat Fin Efficiency
Conventional Fin Efficiency
*The initial period is set at 100%.
Energy Efficiency Stays Strong( 3 times stronger than conventional Fins )
Highly Reliable Flat FinThanks to the flat fin preventing clogging, the initial high energy efficiency is maintained throughout the unit's long lifespan.
* Available only during manual cooling operation.
Inverter & Energy Saving Technology
( PUHZ Series )
( PUHZ Series , M Series )
( M Series )
Reluctance DC Rotary Compressor( PUHZ Series )
( PUHZ Series )
distribution (°C)
14 16 18 20 22 24 26 28
Perceived
Temperature
Sine-wave drive soft PWM
This produces the most efficient waveform in response to varying compressor motor frequency. By improving operating efficiency from low to high speeds, annual electricity costs are reduced.
Vector-Wave Eco Inverter
The inverter has been made compact by insert-moulding the circuit pattern in synthetic resin. To ensure quiet operation, soft PWM control is used to prevent the metallic whine associated with conventional inverters.
Smooth wave pattern
*These classifications are for Split and Multi-Split type air conditioners.
Energy Labeling of Air Conditioners
Outdoor unitIndoor unit
More efficient
Less efficient
Annual energy consumption, kWh in cooling mode(Actual consumption will dependon how the appliance is usedand climate.)
Energy efficiency ratio Full load (the higher the better)
Type Cooling only – Cooling + Heating –
Air cooled – Water-cooled –
Heat output kWHeating performanceA: higher G: lower
Noise(dB(A) re 1 pW)
Further information is contained in product brochures.
All air conditioners with the cooling capacity under 12kW are concerned.Directive defines for each type of product the energy class going from A (more efficient) to G (less efficient). The energy efficiency class is determined in accordance with the following tables.
Norm EN 814Air conditionerEnergy Label Directive 2002/31/EC
Classifications
Energy Efficiency Class In cooling mode
A 3.20 < EER B 3.20 ≥ EER > 3.00C 3.00 ≥ EER > 2.80D 2.80 ≥ EER > 2.60E 2.60 ≥ EER > 2.40F 2.40 ≥ EER > 2.20G 2.20 ≥ EER
Energy Efficiency ClassIn heating mode
A 3.60 < COPB 3.60 ≥ COP > 3.40C 3.40 ≥ COP > 3.20D 3.20 ≥ COP > 2.80E 2.80 ≥ COP > 2.60 F 2.60 ≥ COP > 2.40G 2.40 ≥ COP
ProductAir Conditioners
A B C 1 2 3A B C 1 2 3
A
X.Y
X.YX.Y
X.Y
A B C D E F G
Model Name
Energy Efficiency Class
Annual Energy ConsumptionThe Annual Energy Consumption iscalculated with the total input powermultiplied by an average of 500 hoursper year in cooling mode at full load.
Energy Efficiency RatioHigher EER means better energy efficiency.
Type of Air Conditioner
AB
CD
E
G
Energy
AIR CONDITIONING SYSTEMSManufacturer
F
Cooling output kW
7 8
-
dB
Only
MSZ-FA/GA25
1/2noise
Operation has been made very silent by improvements to the design of the fan blades and the new grille shape. The outdoor unit is even more silent when outside temperature drops as it automatically switches to low-noise mode to reduce operating noise by 3dB.
Silent OperationA low-noise priority function is also available by connecting a commercially available timer or a selector switch. When a signal is received from the timer or the switch, the unit runs in low-noise priority mode.
Low-Noise Priority Function
C
Ultra Silent Indoor Unit OperationNoise level during normal operation is only 21dB for the new MSZ-FA/GA25, making it one of the quietest indoor units in the industry. Inside the unit, the multi-angled heat exchanger has a modified fin shape that reduces air resistance for a smoother, quieter airflow. The wide fan diameter produces greater airflow at lower fan speeds and the uneven pitch between each fan blade helps to eliminate annoying noise. What’s more, the remote controlled vane significantly decreases downward air resistance for much lower noise levels.
Quiet 4 way CassetteReduced airflow resistanceand a redesigned shape of the heat exchanger fin make very quiet operation.
Q. A.In general, why is the reuse of existing
pipework not allowed for models with
R407C or R410A HFC refrigerant?
This is because existing pipework contains moisture and chloride residue that, when mixed with compressor's ester oil, can result in a chemical reaction. Additionally, refrigerant oil sludge and corrosion within the compressor can clog up the refrigerant circuit.
Our Inverter-driven models are the first in the industry to use hard alkyl benzene (HAB) oil — a unique refrigerant oil that degrades very slowly — for refrigeration. Employing our exclusive cleaning-free technologies such as a specially developed high-efficiency oil separator and optimum distribution of heat exchangers to prevent oil stagnation, we have made it possible to reuse previously installed pipeworks.
MSZ Series, MXZ Series (except for MXZ-8A140VA),PUHZ-RP35/50/60/71 Features
New HAB Refrigerant Oil The refrigerant oil (ester oil) used for the 10.0~25.0kw models will degrade when mixed with chemicals such as chloride found in existing pipes. To prevent oil degradation and make it possible to reuse existing pipes, Mitsubishi Electric has developed an exclusive replacement filter that uses activated charcoal to soak up chlorides.
PUHZ-RP100/125/140/200/250 Features
Exclusive Replacement Filter
Mitsubishi Electric’s Cleaning-Free Technology
Replacement filter (conceptual diagram)Refrigerant circuit lasts longer with less deteriorationusing the new HAB refrigerant oil*
*Data taken from our lab: Test results equivalent to 10 years worth of use
Characteristics of the newrefrigerant oil
Colour of the oilat initial stage
Colour of the oil at10 years after use
Name: HAB Oil
Oil characteristics:
Difficult to dissolve in the refrigerant.High chemical and heatstability, uniform quality, high fluidity and viscosity.
Activated carbon (absorbs chlorine and other chemicals)
Filter Outlet
RefrigerantRefrigerant
Inlet
1
2
Silent Operation Technology Cleaning-Free, Pipe Reuse Technology
DAY
50dBin
cooling mode
NIGHT
47dB*in
cooling mode
( PUHZ and Power Multi )
Indoor Unit
Outdoor Unit
dB
Only
PLA-RP35AA
• Reduces installation time for less disruption of business.• Saves installation costs.
• Installation time is reduced significantly, so you have more time to do other work.• Not necessary to find proper pipings for R410A refrigerant.• Time-consuming pipe cleaning is not necessary, even if the owner wants to reuse the existing pipework.
Advantages
For tenants /owner
For installer
Refrigerant condensed in the condenser of the outdoor unit is heat-exchanged with the low temperature refrigerant inside the accumulator, and subcooled. Doing this way, refrigerant will reach the LEV (Linear Expansion Valve) while keeping the optimum state even when the branch box is installed far from the outdoor unit. This has enabled to reduce the refrigerant noise at the LEV section, and has optimized the refrigerant distribution to each indoor unit, proving great effectiveness in the installation environment with a large piping loss (pressure loss) due to a long piping length or a large height difference.
Reduction of Refrigerant Noise
PUHZ-RP125/140:
9 10
-
PAR-21MAA
The air conditioning operation can be switched off automatically thus preventing
waste operation. The set time can be changed from 30 minutes to 4 hours at 30-minute intervals.
Operation Control Function
Auto Off timer
Operationlocking
Equipped with the Long Awaited Weekly Timer
Easy-to-read / Easy-to-use
The setting of the upper and lower limit temperature is possible. This prevents excessive cooling and heating leading to contribute in saving energy.
Limitingthe set temperaturerange
Air conditioning operation Air conditioning operation always within a limited always within a limited temperature rangetemperature range
The function of the weekly timer equipped can change the set temperature in addition to the ON/OFF control. Up to 8 patterns can be set for each calendar day.Industry First!
Multi-language Display
[Japanese]
[English] [Italian] [German][Spanish]
[Russian] [Chinese][French]
Display can be switched overfor 8 kinds of language.
8 languages 8 languages can be displayed.can be displayed.
Weekly timer function capable of temperature control
Automatic turning off of Automatic turning off of air conditioning operationair conditioning operation
Preventing the randomPreventing the randommodification of settingmodification of setting
Busytime frame
Setting to higher temperature
Less busy time frame
4
PAR-20MAAConventional MA remote controller
PAC-YT34STASchedule
timer PAR-21MAA-Gremote controller
Setting Example (Restaurant in summer time)
NEW
Employment of Dot Liquid Crystal Display
Display example [Operation mode]
Acknowledging the operation and control status at a glance. The large size display upgrades visual acknowledgement capability. The operation and control status can be understood promptly.
Effective in energy saving control
Dot liquid crystal display section
Renovating air conditioning communication by advanced MA Remote Controller newly developed
Economical&
Space savingMulti-Ianguage
Control Technology
26
25
24
23
22
0 10 12 14 16 18 20 22 24
Set
tem
per
atu
re(˚
C)
Opening time
Lunch time Dinner time
Setting of 7 patterns
Closing time
Setting to lower temperature
1
2
3 5
6 7
(Hr.)*Result of cooperative study with Japan Facility Solution Co, Ltd.
COOL / DRY
Office RestaurantRecommend to use in
Lower limit temperature
Possible setting range (standard)
19(˚C) 30(˚C)
30(˚C)25(˚C)
To prevent excessive coolingThe lower temperatures cannot be selected.
Meeting roomRecommend to use in
* The "Simple timer" (starts and stops in a unit of one hour within 72 hours) set at factory shipment can be changed to the "Auto off timer" by switching the function of the remote controller.
* The change of setting may be limited to the administrator who knows the method to release the locking.
Public facility like public hall
Recommend to use in Office School / private school
Hospital Server room
Setting to invalidate all buttons or the operation other than with ON/OFF button
is available. This always assures operation under an adequate temperature preventing the meaningless change of set temperature, leading to effective energy savings. This is also effective to prevent erroneous or mischievous operation.
about10%Energy Saving
*Setting the temperature to “1˚C higher in cooling”while “1˚C lower in heating” results in about 10% energy saving. *Based on our internal calculation
ON/OFFTEMP.
Conventional inspection work
Easy maintenance information
Easy Maintenance Function (Only for Power Inverter Mr.Slim) Reduces maintenance work drastically. Enables you to check operation data of the indoor and outdoor units by remote controller. Furthermore, you can fix the operating frequency, from the remote controller for smoother inspection.
Refrigerant Leakage Check (only for PUHZ-RP HA2) The latest “Power Inverter” Mr. SLIM (PUHZ-RP HA2) has got a new useful “Refrigerant Leakage Check” function.With this function, the refrigerant leakage which may happen during a long period of use can be easily checkedwith a wired remote controller. Not only time for servicing can be saved, but you also get peace of mind.
Accumulated operating time (x10 hours)
Number of ON/OFF times (x100 times)
Operatingcurrent (A)
Heat exchanger temperature (˚C)
Dischargetemperature (˚C)
Outdoor air temperature (˚C)
Intake air temperature (˚C)
Heat exchanger temperature (˚C)
Filter operating time* (Hours)
Outdoor unitCompressor Indoor unit
1
2
3
4
5
6
7
8
9
*The filter operating time is the time elapsed since the filter was reset.
Discharge temperature 64˚C
Indoor unit Outdoor unit
Remove the service panel
Measurethe intake air temperature
Measure the discharge temperature
Measure the outdoor air temperature
NEW!
11 12
-
1
2
3
4
5
1-remote controller control
Standard System
2-remote controller control
With 2 remote controllers, control can be performed locally and remotely from 2 spots.
Group Control
One remote controller can control plural air conditioners simultaneously under a same setting.* The setting of the refrigerant add-
ress is required for outdoor unit.
Operation Control by Level Signal (DC12V)
Air conditioner can be started/stopped remotely. In addition, the ON/OFF by local remote controller can be prohibited/permitted.
Operation Control by Pulse Signal
Remote Display of Operating Status
Operating status can be displayed at a distant place.
Allows ON/OFF with timer *For the control by external timer, refer to D Operation Control by Level Signal.
Centralized control of dispersed air conditioning equipment allows effective monitoring/controlling.
LOSSNAY can be controlled with remote controller
Timer Operation
Centralized Control
Interlocking with LOSSNAY
SYSTEM CONTROLS
PAR-21MAA-G
(Example of 1 : 1 system)
Signal receiver
PAR-21MAA-GPAR-21MAA-G
(Example of 1 : 1 system)
(Example of 1 : 1 system)
(Example of 1 : 1 system)
PAR-21MAA-G
Relay box (to be purchased) locally)
Relay box (to be purchased) locally)
Adapter for remoteON/OFF
Adapter for remoteON/OFF
Indoor CN51
PAR-SL97A-E
PAR-SL97A-E
(Example of 1 : 1 system)
PAR-21MAA-G
(Example of 1 : 1 system x 2)
(Connection with M-NET system)
Centralized remote controller G-50, etc.
Power supply unit
LOSSNAY operation cable
LOSSNAY
Wired remote controller
M-NET adapterPAC-SF80MA-E
Indoor CN51
Remote operation adapter
(Example of 1 : 1 system x 2)
Relay box (to be purchased locally)
(Example of 1 : 1 system x 2)
* Set "Main" and "Sub" remote controllers. * When you use wired and
wireless remote controllers
PAR-SL97A-E
(Example of Simultaneous Twin)
PAR-SL97A-E
(Example of Simultaneous Twin)
(Example of Simultaneous Twin)
PAR-SL97A-E
(Example of 1 : 1 + Simultaneous Twin)
• Wired Remote ControllerPAR-21MAA-G
• Wired Remote Controller Kit for PKAPAR-21MAAT-E
• Wireless Remote ControllerPAR-SL97A-E
• Wireless Remote Controller Kit for PCAPAR-SL99B-E
• MAC-397 IF-E is required for each indoor unit if the outdoor unit is SUZ or MXZ. (If the outdoor unit is P series,
no optional parts are required.)
• Adapter for remote ON/OFFPAC-SE55RA-E
• Relay box (to be purchased locally)• Remote control panel (to be purchased
locally)
Standard functions of PAR-21MAA-G
M-NET adapter:PAC-SF80MA-E
*If the outdoor unit is SUZ or MXZ,please refer to [1] 2 on page 13
SLIM-LOSSNAY connection cable
Versatile system controls can be realized by using optional parts, relay circuits, control panels, etc.
A
B
C
D
E
F
G
H
I
Details Major optional parts requiredSystem examples
Wired remote controller Wireless remote controller
Remotedisplaypanel
Remotedisplaypanel
Indoor CN32
PAR-21MAA-G
Remotecontrolpanel
RemotecontrolpanelWired remote
controller
Wired Remote Control
Centralized Control
Remote ON/OFF Operation
Remote Display of Operation Status
Interlocking with LOSSNAY
[1] For M series Indoor Units (New A-control models only) [2] For P series and S series Indoor Units
Control detail Major optional parts requiredSystem examples Connection detail
• MAC-397IF-E (Interface)• PAR-21MAA-G (Wired remote controller)
• MAC-397IF-E (Interface)• MAC-821SC-E (Centralized remote controller)
• MAC-399IF-E (M-NET Interface)• Centralized controller for City Multi, like G50, and power supply unit, etc.
• MAC-397IF (Interface)• Parts for circuit such as relay box, lead wire, etc. (to be purchased locally)
• MAC-397IF-E (Interface)• Parts for circuit (to be purchased locally/ DC power source needed)
Wired remote controller can be connected to indoorunit via interface.
Centralized remote controller can be connected to each indoor unit via interface.
M-NET connection is possible via interface.
Connect interface to air conditioner and setup a circuit by using the terminal inside theinterface locally.
Connect interface to air conditioner and set up a circuitby using the terminal inside the interface locally.
LOSSNAY can be connected to indoor unit via an interface.
With wired remote controller, operation mode/set temperature/fan speed/vertical air direction*1, and timer operation *2 can be controlled.
Individual ON/OFF and switching OFF at a time is possible with centralized controller.The ON/OFF status of each unit can be confirmed by the LED on the centralizedremote controller.
Individual ON/OFF and switching OFF at a time is possible.Operation mode, temperature/fanspeed/air direction*1 andtimer settings *2 can be changed individually.
ON/OFF is possible from a distant place
The operation status (ON or OFF) or error signals can be monitored from a distant place.
LOSSNAY can be operated simultaneously with the indoor unit.
• MAC-397IF-E• Cable for LOSSNAY connection (to be purchased locally)
• Up to 8 indoor units can be switched ON/OFF with one remote controller.
• Air conditioner can be group controlled with City Multi (M-NET).
• Air conditioners can be controlled by wired remote controller equipped with Weekly Timer function.
For further details, refer to the separate manual.*1 Not applicable to the models without air direction control.*2 For timer setting, do not use the wireless and wired remote controllers together.
Outdoor unit
Indoor unit
MAC397IF-E
PAR-21MAA-G
Indoor unit
MAC-821SC-E
MAC-397IF-E
City Multi outdoor unit
City Multi indoor unit
MAC-399IF-E
ME remote controller (PAR-F27MEA)
Localremotecontroller
City Multi indoor unit
G-50, etc.
Power supply unit
Outdoor unit
Indoor unit
MAC-397IF-E
Remote control section(to be purchased locally)
Switch
Outdoor unit
Indoor unit
MAC-397IF-E
Remote monitor section (to be purchased locally)
Power supply
MAC-397IF-EOutdoor unit
Indoor unitLOSSNAY
Outdoor unit
Resistance LED
• Either wired type or wireless type remote controller can be used.
• Up to 2 remote controllers canbe connected to 1 group.
• Both wired and wireless remote controllers can be used in combination.
• One remote controller can control up to 16 refrigerant systems.
• Outdoor unit can be started/ stopped (thermostat ON/OFF) individually.
• Up to 2 remote controllers can be connected.
• Operation other than ON/OFF (adjustment of temperature, fan speed, and air direction, for example) can be performed even when remote controller operation is prohibited.
• Timer control is possible with an external timer.
Adapter for remoteON/OFF
Adapter for remoteON/OFF
PAR-SL97A-E
(Example of 1 : 1 system x 2)
Relay box (to be purchased locally)
(Example of 1 : 1 system x 2)
• Adapter for remote ON/OFFPAC-SE55RA-E
• Relay box (to be purchased locally)• Remote control panel (to be purchased
locally)Indoor CN51Remotecontrolpanel
RemotecontrolpanelWired remote
controller
• Operation other than ON/OFF (adjustment of temperature, fan speed, and air direction, for example) can be performed even when remote controller operation is prohibited.
• Timer control is possible with an external timer.
• Operation/emergency signal can be received at a distant place (no-voltage signal).
• Weekly timer:ON/OFF and up to 8 pattern temperatures can be set for each calendar day.(Initial setting)
• Simple timer:ON/OFF can be set once each within 72 hr. in a unit of one hour.
• Auto-off timer:Operation will be switched off after elapsing a certain time. Set time can be changed from 30 min. to 4 hr. at 30 min.
intervals.*Simple timer and Auto off timer cannot be used at the same time.
• Mounting the adapter for M-NET connection to the outdoor unit allows MELANS (M-NET system) connection.
• Allows centralized control by MELANS.
• LOSSNAY can be connected to the indoor unit.
None
• Remote display panel (to be purchased locally)
• Remote ON/OFF adapterPAC-SE55RA-E
• Connector cable for remote displayPAC-SA88HA-E/ PAC-725AD (10 pcs. x PAC-SA88SA)
• Remote operation adapter PAC-SF40RM*Unable to use with wireless remote controller
• Remote display panel (to be purchased locally)
• Air conditioner can be started/stopped remotely.( 3 and 4 can be used in combination)
• The ON/OFF status of air conditioner can be confirmed remotely.( 3 and 4 can be used in combination)
• LOSSNAY can be operated simultaneously with the indoor unit.
MAC-397IF-E*
MAC-397IF-E*
NOTE: TWIN,TRIPLE,QUADRUPLE Operation is possible only in the limited combinations. Please refer to page 90 for details.13 14
-
Plasma Deodorizing FilterThe newly equipped "Plasma Deodorizing Filter" provides state-of-the-art deodorization-decomposition and elimination of harmful chemical substances at the nanolevel (1/1,000,000 of a millimeter). The key to high power deodorization of the most unpleasant odors*1 in daily life such as ammonia, methyl mercaptan, trimethylamine and hydrogen sulfide.
■ Maintenance is a snap - just wash these units in water!
■ removes various things
To care for both the Plasma Deodorizing Filter and the Plasma Air Purifying Filter, just wash them in water. The deodorizing ceramic filter, meanwhile, is an extended use model, boasting a service life of about 6 years.
Plasma Air Purifying FilterArmed with the "Plasma Air Purifying Filter," which has already built up a solid reputation in Japan, the pollutants in your room air are removed thoroughly than ever before. Besides collection of fine house dust, pollen and other annoying substances, this filter also provides disinfecting and anti-virus effects.*2 Negative ions, with their soothing and relaxing effects, are also generated.
*1: Not all odor components generated on a continuous basis (building material odors, pet odors) can be removed.
*2: Source: KRCES-Bio study Report No.16 00865 (November 22, 2004)
Bad Odors FormaldehydesmokeDust
Powerful Collection Powerful Deodorization Bacteria Elimination
Mold spores, Pollen
VirusesBacteria
■ Plasma Air Purifying Filter mechanism
■ Plasma Deodorizing Filter mechanism
Electrically conductive and semi-insulatingresin adsorption componentCatches electrified particles.
Deodorizing Ceramic Filter
GND electrode
Plasma electrode unit
GND electrode
■ Plasma Deodorization,s Effect on Ammonia
100%
80%
60%
40%
20%
0%
With Plasma Deodorization
Without Plasma Deodorization
Operation time ( minutes )100 20 30
Am
mon
ia o
dor r
esid
ual r
ate
Plasma electrode unitThe dirty molecules are electrically charged, while odor molecules decomposed down by radicals.
*1.1wh each for Plasma Deodorizationand Plasma Air
Purification.
Quick Clean
With our new moving "i see sensor",no temperature gap goes free.
Plasma Air Purifying FilterAnti-mold Pre Filter
Vane
Plasma Deodorizing Filter
Front Panel
The inner fan is placed within ready reach, for handy cleaning.
The moving "i see sensor" automatically moves from side to side, searching out temperature disparities over a wide area of 150°. Thanks to this advanced sensing technology, and the wide airflow of 150° from left to right (90° in cooling mode), all corners of even the most spacious rooms are kept comfy.
Warmer area
Warm air aims the cooler areas.
Cooler area
Warm air aims the cooler areas.Daytime Nighttime
■ In heating mode (with AREA setting : whole room)
Fan Guard
With the AREA button, efficient, energy-skimping heating and cooling is realized for the target space – the right side, left side or the room as a whole. The sensor also operates only on the selected side.
“Area Setting”– for waste-free, energy-saving heating and cooling.
Advanced airflow control supported by a newly configured horizontal vane enables the warm air to reach the floor level in heating mode. In cooling mode, the vane angle can be kept nearly horizontal, for a pleasant and refreshing feeling that comes out more health conscious all around.
Airflowdistr ibut ioncomparisons
Model from 10 years ago
Vertical section Horizontal section
MSZ-FA
*in heating mode : outdoor temperature 7°C / room size 13.2m2
■ An improved "horizontal vane," for even more pleasant and refreshing airflow
Wide Detection
When choosing an air-conditioner, besides the natural yardstick of comfort, interior compatibility is another key choosing point. At Mitsubishi Electric, our highly compact and refined designs provide excellent fits for a vast range of rooms. The “glossy pure white” hue, meanwhile, will accentuate your attractive interior with yet another eye-catching touch.
Auto Front PanelTurning the unit “ON” makes the front panel to open, activating the cooling or heating operation. Switch “OFF” and the panel closes, striking a smart and sleek appearance to the eye.
When not in use
198mm*
Compact design, only 780mm wide. Just right for your home interior.
780mm
*
A ceramic filter equipped with newly developed nano-hole manganese catalyst. Engineered for streamlined catching and crushing of odor-causing elements over an impressive surface area of 1,750m2 (approx. 7 tennis courts).
Heating at -20˚CPossible with the models mounted with the anti-freeze heater on the outdoor unit drain pan.
※2.5kw class
The easily detachable front panel is a snap to wash, and the airflow vents can be opened without any special tools for quick cleaning inside the air conditioner. It is recommended that the air conditioner be cleaned regularly, to increase operating effi-ciency and energy savings alike.
Quick Clean Design slashes your electric bill by approx. 30%*3
Quick Clean Kit is easily connected to household vacuum cleaners*4
*3 Electric bill comparisons of the operation at fixed temperature with 8 g of dirt on the fan and the one without. Based on the in-house data. *4 The wearing of gloves is highly recommended when cleaning the heat exchanger, because touching the heat exchanger with bare hands can cause injury.
Exclusive Quick Clean Kit (standard)
In order to completely satisfy human thermal sensation,even the floor/wall temperature in addition to the room temperature are measured by our . This results in more effective cooling and heating with less waste operation.
Roomtemperature30.9%
Humidity20.7%
Floor/walltemperature43.7%
Decisive factors for sensible temperature (in a room)
FA SeriesThe Plasma Duo goes beyond just catching the unpleasant odors, and proceeds to powerfully crush them. The all-out pursuit of real air quality.
※
15 16
AREA
-
MFZ SeriesFor your Living Room, or Bed Room.The latest Mitsubishi innovation – floor standing air-conditioner sophisticated in design, rich in function.
i save mode
Optimum Air Distribution Cleaner and Healthier Air
Trouble-Free Installation and Maintenance
Sophisticated Design
Slim but Mighty
Quiet Operation
From Mitsubishi Electric, an innovative new floorstanding air-conditioner. Our pleasing mix of streamlined form and diversified function. Engineered to keep room walls free, furnish comfy cooling in summer, toasty heating in winter. The “Glossy Pure White” colour ensures a deluxe look, the perfect match for any room. Both upper and lower air outlets remain closed when switched OFF, in a smart and striking image. A superb new air-conditioner from Mitsubishi, providing a handsome fit for your own distinctive interior.
The unit body is slim and trim, the essence in compact. An ideal size for living rooms, bedrooms, attics and more.The removable and washable front panel makes cleaning a snap.Easy and regular cleaning allows your air-conditioner stay beautiful while keeping its energy efficient operation always possible.
Comfy room temperatures are realized by the optimum, powerful and efficient air distribution through upper and lower air outlets.The upper vane angle is remote controllable, with 5 air flow direction levels (+ Swing and Auto modes) and 4 wind power levels (+ Auto mode).By setting the vane angle almost vertical, annoying direct wind can be avoided for your better comfort.
A simplified set back function enables to recall the preferred (preset) temperature with a single push of the button on the remote controller. Press the same button again and you can go back to the previous temperature setting in an instance.When leaving the room, going to bed or at other times, this button helps you to realize the wisest and the most suitable air conditioning. A handy function for comfortable and waste-free environment pursuit, the Mitsubishi way.
To install the indoor unit, position with our original installation plate, then set the unit place. Easy leveling work prevents any harm towall surfaces. Generous pipe length, up to 20 or 30 meters, eliminates worries about outdoor unit distance. Loaded with automatic diagnosis function, trouble log recall mode and other sophisti-cated aids, troubleshooting is immediate though pro-blems are rare.
The air from both upper and lower air outlets is optimally controlled and distributed evenly to every corner of the room. In heating mode, the warm air is smartly controlled to stay at the floor level: Your feet do not feel chilled any more!
Waste-free operation – energy-stingy to the hilt.The optional wired remote controller (PAR-21MAA)* with “Weekly Timer” function enables 8 separate pattern settings over a single day’s time. Use the optional “Centralized ON/OFF Controller (MAC-821SC-E)*” to exercise regulate all rooms. ON/OFF selection and operation status con-firmation is possible with a single controller.
700mm
60
0m
m
200mm
■ "Anti-Allergy Enzyme Filter" mechanism
■ Smarter Control, with a Single Remote Controller
SS
ArtificialEnzyme
ArtificialEnzyme
CatechinFilter
TransformationTransformation
Transformed protein =Non-allergen proteins
Allergen protein (Such as mites)
S
S
Filament Filament
Artificial enzyme catalyst on the filament catches the allergens.The artificial enzyme cata-lyst helps the chemical reaction with Oxygen and severs the S-S bonds.*4
Proteins with severed S-S bonds are no longer aller- gen proteins.
*4: Mites and other allergen protein consist of sulfur atoms (S) that have bonded together.
Transformation
*1 : "Inactivation" refers to curbed activity. *2 : Confirmed by the Japan Spinners Inspecting Foundation. Test numbers JSIF-029220-1/JSIF-029220-2. *3 : Confirmed by Shinshu University.
Catechin + Anti-Allergy Enzyme Filters Achieve deodorization, allergen inactivation,*1 bacteria elimination*2 and antiviral effects. Elevating the pursuit of health-conscious air to unequaled heights. In addition to the "Catechin Filter" with deodorizing effect, the"Anti-Allergy Enzyme Filter" catches dead mites and their droppings, pollen and other allergens on the filter filament, then decomposes them with artificial enzymes*3. What's more, the steriling agent generates greater antiviral effects, supporting a cleaner and healthier air supply.
i save
Mitsubishi Electric air conditioners have always been some of the quietest models available in the market. Our new floor standing models are no exception.It can create a silent and comfortable space where the occupants would not even recognize the existence of air conditioner operation.
Sleek louvers look just like flat panels
Smart upper/lower air outlets close when switched off
Deluxe look in “Glossy Pure White” color
● Installation Plate
● Noise level
*requires special interface(MAC-397IF-E)
PAR-21MAA
MAC-821SC-E
Anti-AllergyEnzyme Filter
10dB40dB60dB80dB
Subway car interior
Quiet passenger car interior (40km/h)
Library interior
Human hearing limits (Extremely quiet)
Sound of rustling leaves
22dB
※2.5kw class
thequietest!
22℃ 18℃
14 16 18 20 22 24 26 [℃]
22※
17 18
* It is recommended to soak the filter in water every three months. The standard interval of filter replacement is for one year.
i save
-
Before replacement:Installed 8 years ago
Model name PLH-3GKHB/PUH-3YKA
After replacement:Power Inverter
Model namePLA-RP71AA/PUHZ-RP71VHA
Conditions of trial calculation ( according to Japan Refrigerant Association )
Power Inverter Non-Inverter (R407C)
COP
Outdoor Unit
3.5
3.0
2.25
3.60
3HP
2.61
3.30
4HP
2.55
3.21
5HP 6HP1.6HP 2HP 2.5HP
2.17
3.23
2.42
3.36
2.40
3.64
2.40
2.81
Average
38%increase
Comparison of COP between non-inverter and power inverter (4-way cassette type) models.
70%reduction
60%UP
52%UP
26%UP 26%
UP49%UP
39%UP
R407CNon-Inverter
R410APower Inverter (Maximum capacity)
1.6HP 4.4 4.5 102%2HP 5.3 5.6 106%
2.5HP 6.3 6.7 106%3HP 7.7 8.1 105%4HP 9.6 11.4 119%5HP 12.7 14.0 110%6HP 14.2 15.3 108%8HP 20.9 22.4 107%10HP 26.0 28.0 105%
Cooling capacity
3HP 3.3-8.1 kW
5HP 5.5-14.0 kW
4HP 4.9-11.4 kW
6HP 5.5-15.3 kW
8HP 10.0-22.4 kW
10HP 12.5-28.0 kW
0 2 4 6 8 10 12 14 16 18 20 22 24 26kW
Cooling capacity ranges
Running current comparison.
The cooling & heating capacities at the maximum operatingspeed have also been improved by up to 33% compared to the current model.
Operation is now possible at lower speeds, thus cutting energy losses produced by the repeated on/off operation of non-inverter models. Comfort is improved while power consumption is reduced.
Higher Cooling & Heating Power Wider Performance Range
3 phase power supply "Power Inverter" (RP100 - 250YHA)
The other features; *Replace filter equipped (to Reuse the existing pipe works) *High efficiency operation *Silent operation (Only 52dB in silent mode: 20.0kW)
Compact top flow models(20 & 25kW Power Inverter)
By additional filling with refrigerant, it is now possible to have pipes up to 120 metres long, making it easier to select a layout to install the unit.
Dramatic reduction of running current is realized by 3 phase power supply. The special technology is installed in the outdoor unit to comply with the Electro Magnetic Compatibility in Europe.
Harmonics Filter Technology
We have successfully complied with the EMC regulations (EN61000-3-2,Class-A) first in the industry in the category of 3 phase inverter driven air conditioners requiring less than 16A current input.
Less than half in the running current and the breaker size !!
The Other Features -20˚C Heating is possible
(for RP100/125/140/200/250)
Cleaning Free Pipe Reuse. Silent Operation (outdoor unit)
Longer Piping Length
Max Height difference Max piping Length
PUHZ-RP35/50
PUHZ-RP60/71
PUHZ-RP100/125/140
30m
30m
30m
50m
50m
75m
PUHZ-RP200/250 40m 120m
Max Piping Length can be stretched to 120m1. Power Consumption
Energy Saving
2. COP
Based on our calculations on the operating conditions shown below, the new Power Inverter system can reduce power consumption by approxi-mately 70% compared to an old model installed 8 years ago.
17%UP
990
300
990
500
750
900
100
450
198kg225kg
1.97m2 1.17m2
3 phase
1 phase
Rated (cooling)
Rated (heating)
Max
Breaker size
Rated (cooling)
Rated (heating)
Max
Breaker size
3.79
4.33
13
16
12.33
13.94
28
32
4.85
5.41
13
16
15.8
17.5
28
32
6.49
6.37
13
16
20.73
20.37
29.5
40
10kW
990990 750
900
Unit size
Unit: mm
Unit: mm
SpaceforServicing
PUH-8YD New Power InverterPUHZ-RP200YHA
DepthReduced by240mm
WeightReduced by
Space for Servicing
*In case of installing one intake/blow off open unit
27kg
Service spaceReduced by 40%
Outdoor Units
Wall Mounted4 Way Ceiling Cassette
Ceiling Concealed
Professional Kitchen
Floor Standing
Ceiling Suspended
Thanks to the new Power Inverter system, a large reduction in power consumption is now possible. This results in one of the highest COP ratings in the industry, helping to lower overall running costs and providing great savings to customers.
Power Inverter
Indoor Units
converter circuit
1.6HP 1.6-4.5kW
2HP 2.3-5.6kW
2.5HP 2.7-6.7 kW
12.5kW 14.0kW
The greatly improved COP contributes to reduce your electricity bills drastically.
Comparison of unit size and space for servicingPlace Office in Tokyo (Japan)
Operatingtime
8AM to 8PM (12 hours/day)& 6 days/week
Settemperature Cooling: 27°C, Heating: 20°C
Cooling: April 16 ~ November 8Heating: December 14 ~ March 23
Operatingperiod
19 20
-
Standard InverterOur New Inverter Features Energy Saving, Compact Design, Light Weight, and Basic Performances as well.
Pump down switch
Pump down switch
Indoor unit control circuit board
SUZ-KA35VA SUZ-KA50/60/71VA
PUHZ-P100 PUHZ-P125/140
To meet your interior or space designing, optimum indoor units can be selected from 8 types that include 4-way ceiling cassettes.A combination with different type indoor units in two or three rooms besides 1:1 combination can be constituted thus satisfyingvarious applications.
The silent operation of the outdoor unit Model P100 has attained down to 50dB (cooling).Further 3dB can be reduced under the Silent Operation Mode.
-15℃ OK!
Merely pushing a switch starts / stops refrigerant recovery operation auto-matically. This work will be completed only by closing a valve.
New refrigerant R410A with zero ODP (Ozone Depletion Potential) is employed. Smooth refrigerant recovery can be assured by only pushing the pump down switch at unit movement / renewal.
4 Way Ceiling CassettePLA-AA
Ceiling ConcealedPEAD-GA
Ceiling ConcealedPEAD-EA
Floor StandingPCA-GA
3dB reduction
Reducing sound more by Silent Control!
Day
Outdoor temperature: 35℃
50dBNight
Outdoor temperature: 25℃
47dB
Model P100 (cooling)Suppressing to
about 1/2 audible sound (compared to daytime)
Photo indicates for Model P100.
Possible CombinationsCapacity
PEAD-EA
●
●
●
●
●
●
PEAD-GA
●
●
●
PLA-AA ●
●
●
●
●
●
PCA-GA ●
●
●
●
●
●
PCA-HA
●
●
PKA-GAL ●
PKA-FAL ●
●
●
PSA-GA ●
●
●
●
50/60/71 models are for Twin & Triple use.
5.0kW
6.0kW
7.1kW
10.0kW
12.5kW
14.0kW
Possible CombinationsCapacity
PEAD-EA
●
●
●
●
PEAD-GA
●
●
SEZ-KA ●
●
●
●
SLZ-KA ●
●
●
●
PLA-AA ●
●
●
●
PCA-AA●
●
●
SUZ-KA35
SUZ-KA50
SUZ-KA60
SUZ-KA71
21 22
Greater Energy Saving When Compared to Fixed Speed Unit
A Product Line of 31 Models in 8 Types Responds to Your Versatile Needs.
S series outdoor unit can be connected not only with SLZ and SEZ but also some P series indoor units. Greater inverter line up satisfies your various requirement.
Another possibility! Compact S series outdoor unit can now be connected to P series indoor unit as well.
Design with Environmental Consideration
Heating Operation Possible Even at -15˚C Outside Temperature
Easier Installation Work Thanks to Compact and Light Weight Design
For Easier Installation
Silent Outdoor Unit
COP improved by 27%
2.61
2.61D
2.69
2.69E
EER COP
3.413.41B
COP
3.01
3.01B
EER
Comparison with 4-way cassette (4HP) models
New inverter PUHZ-P100V
R407C Fixed speed unit PUH-P100V
Reduced by
407mmReduced by
46kgReduced by
317mmReduced by
22kg
R407 Fixed Speed New Inverter75kg 75kgPower Inverter New Inverter
407mm
121kg 97kg
900mm330mm
1350mm
1260mm
943mm
950mm 950mm330mm330mm
The outdoor unit model P100 counts for 943mm only for the height and 75kg for the mass. A significant weight reduction of 46kg has been attained compared to the Power Inverter. The burdening of installation/transportation work can be lightened by the compact design and light weight.
●Refrigerant piping can be extended up to 50m by charging refrigerant additionally.
●Slenderized piping facilitates installation workSlender pipe employed provides easier bending work, minimizes working
hour and saves materials leading to cost reduction.
●4-way piping connections Piping can be connected in the direction of front, rear, bottom and right.
Dividing the piping cover panel into two portions improves workability of
internal piping.
●Compared to Power Inverter ●Compared to fixed speed unit
P100
P125 / 140
P100 / 125 / 140
Chargeless piping length
20m
30m
R410A New Inverter
φ9.52 / φ15.88
R407C non Inverter
φ9.52 / φ19.05
Maximum piping length
50m
50m
(Liquid pipe / gas pipe) Unit: mm
317mm
943mm
950mm330mm
Outdoor Unit Indoor Unit
Outdoor Unit Indoor Unit
NEW!
NEW!
NEW!
-
MXZ seriesOur Strengthened MXZ Lineup Provides a Quiet,Highly Efficient and Flexible Air Conditioning SystemFor All Your Air Conditioning Needs
MXZ-A14/18WV MXZ-2A
Down weighted by
12kg
Downsized by
30%
Compact Outdoor Units 40kgNEW
10~15m30~70m
30~70m
285800330 840
640
550
OutdoorUnit
Branch Box
Up to 8 indoor units can be connected !
Suggestion for indoor unit selectionFor a large living room, the Ceiling Concealed or
the Compact Floor Standing type easily match the fancy interior.For a bed room, the Wall Mounted type creates
a more silent atmosphere.For 600 x 600 system ceiling, the SLZ type
facilitates your installation work.For a larger meeting room and the like,
the PLA type offers the powerful performance.
Advantage of Power Multi System
The latest technology obtained through the development of our well-reputed Power Inverter series offers the higher COP, the industry top class.
The Power Multi runs so smooth and quiet, you get comfort without any of the bothersome noise. Under low operating load, the “Low-noise” mode will automatically be selected thus providing more silent operation. Connecting with our latest wall mounted indoor units allows creating a silent and comfortable space where the occupants would not even recognize the existence of air conditioner operation.
Not only the branch box simplifies the piping work, the flare connection adopted eliminates the use of fire for easier and safer installation.
High COP
The MXZ-2A/3A/4A can be connected to maximum of 2, 3 & 4 indoor units, optimizing use of outdoor space and enhancing exterior aesthetics.
Regarding new MXZ-2A, a significant reduction was marked both in the size and the weight thus facilitating installation work.
Single Compact Outdoor Unit Saves Space
The key to attractive installation and optimum indoor dimension use. Select the best suited model from 12 types covering 6 capacity ranges: 4 types of wall mounted, 4 types of ceiling concealed, 2 x 2 ceiling cassette, Power Cassette,Compact floor standing and ceiling suspended models.
Select from Wide Range of Indoor UnitsChoose from 12 Types
Silent Operation
Easy Installation
System ImageFeatures of the Branch Box
Outdoor Installation
Indoor Installation
Using the optional cover allows you to install the branch box outdoors. There is no need for a maintenance hole in your ceiling.
The branch box can be installed inside above the ceiling.By only removing the side and bottom covers, you can access the inner parts like the circuit board providing a great convenience in servicing.
Noise Kept to a Minimum The branch box houses the linear expansion valve (LEV), a valve which coordinates the flow of refrigerant and tends to produce a certain amount of noise. Since the branch box can be positioned in the ceiling or outdoors, it keeps the noise inevitably generated by the linear expansion valve away from living spaces, allowing a comforting silence to prevail.
Wall Mounted – DeluxeMSZ-FA
Wall Mounted – StandardMSZ-GA /GB
Compact Floor StandingMFZ-FA
Ceiling Cassette – 600 x 600mmSLZ-KA
Ceiling Cassette – Power CassettePLA-RP
Ceiling Concealed – CompactSEZ-KC /KA
Ceiling ConcealedPEAD-RP EA
Ceiling Concealed – Thin TypePEAD-RP GA
2.2kW 2.5kW 3.5kW 5.0kW 6.0kW 7.1kW
SELECTABLE INDOOR MODELS
Wall Mounted – DeluxeMSZ-FA
Wall Mounted – StandardMSZ-GA/GB
Wall Mounted – StandardMSZ-CB
Compact Floor StandingMFZ-FA
Ceiling Cassette – 600 x 600mmSLZ-KA
Ceiling Cassette – Power CassettePLA-RP
Ceiling Concealed – CompactSEZ-KC/KA
Ceiling ConcealedPEAD-RP EA
Ceiling Concealed – Thin TypePEAD-RP GA
Ceiling SuspendedPCA-RP
2.2kW 2.5kW 3.5kW 5.0kW 6.0kW 7.1kW
SELECTABLE INDOOR MODELS
PAC-AK50BC
PAC-AK50BC
MXZ-8A140VAPAC-AK50BC
DCInverter
EER
ACOP
APower Multi MXZ-8A140VADC
Inverter
EER
ACOP
ASmaller MXZ 2, 3 and 4 ports
Silent Operating Sound,the Top class in the Industry
Operable under Low OutdoorTemperature
Function to Fix Operation Mode
Upgraded Installtion Ability
The industry top class silent operation of the indoor and outdoor units neither hinder your comfort nor bother your neighbour. Setting the outdoor unit to the Silent Mode reduces the operating sound by 3~4dB further.
Both cooling and heating operation are possible even in winter with an outdoor temperature of -10°C. Cooling may be useful in pubs and the like crowded in heated atmosphere even in winter.
Fixing of operation mode can prevent operating in an erroneous mode. Especially convenient in places where many people gather such as in hotels.
Flexibility in selecting installation spaces is upgraded by extending the total piping length to 30~70m, and the height difference to 15m.*Reuse of existing piping free of cleaning and outdoor unit power supply minimize installation time required.* Reduced to 10m when installing outdoor unit higher than indoor unit* MXZ-4A80VA : 10m
MXZ-4A80VA
MSZ-FA
MFZ-FA
SEZ-KA
SLZ-KA
System Image (example of MXZ-4A80VA system)
GB
* *
KC
Flexible Choice of Indoor unitThe Power Multi satisfies all your needs. You can choose an indoor unit optimum for the application, interior and size of your room from the versatile product line of 27 models in 10 types.
Brazing Free Quick InstallationAll the pipings leading to and from the branch box is connected by way of flare joints. Flare joints are easy to use and connect pipes quickly.
*MXZ-3A54 in cooling (Silent) mode
GB
MXZ-2A40/2A52VA MXZ-4A80VAMXZ-3A54/4A71VA
2port 3port 4port 4port
indoor 21dB(MSZ-FA/GA25)outdoor 43dB*
23 24
*MSZ-CB: only for MXZ-2A/3ANOTE: (1) MXZ-2A : Indoor units up to 3.5kW size can be connected. (2) MXZ-3A54 : Indoor units up to 5.0kW size can be connected.
(3) MXZ-4A71 : Indoor units up to 6.0kW size can be connected. (Except for PEAD-RP60GA)(4) MXZ-4A80 : Indoor units up to 7.1kW size can be connected.
*The maximum possible piping length/height differ among each model.
**
*
-
25
DCInverter
PAMControl
EER
ACOP
A
Econo CoolAREA
Only
21dBSWING
HORIZONTAL
SWINGHORIZONTAL
SWING
VERTICAL
AUTOVANE
Wide Long
VERTICALAIR FLOW
Anti-AllergyEnzyme Catechin
Fresh Air Intake
Anti-Mold Air-Cleaning
Deodorizing
Auto Panel Flat Panel
270mm
Compact
GlossyWhite
2x2Size
Compact
Cooling at
-10̊CHeating at
-20̊C
i save
Auto Restart
Cooling at
46 C̊/-10 C̊
24-hour Timer
ACO
WeeklyTimer
CentralizedOn/Off M-NETconnection
Heating at
-10̊C
Quick Clean
EasyInstallation
with Leveling Plate
MXZconnection SelfDiagnosis
FaliureRecall
Flareconnection 20m
12m
72patterns
Hot Start
4 notch 2 notchHighCeiling
Quiet
Lossnayconnection
Long Life Check!High efficiency
I FEEL
COMPOGroupControl
DrainLift UP
75m
IN/OUTPower Supply
Anti moldDP
120m
WiringReuse
EasyMaintenance
Handycorner pocket
IconsEnergy Saving
Comfort
Fresh Air
DC Inverter PAM control
Econo CoolAREA settingi-see Sensor
EER A
'I FEEL' Control
COP A
Super Quiet : Only 21 dB Auto Vane
Wide & Long AirflowSwing (vertical vane) Swing (horizontal vane)
Vertical Air flow
High Ceilling Air Flow Setting 72 Patterns Air Flow 2 Notch Fan Speed
Hot Start
Quiet operation
4 Notch Fan Speed
Plasma Duo Filter Systems
Air Cleaning FilterAnti-Mold Air Cleaning FilterCatechin Filter
Fresh Air Intake
Anti-Allergy Enzyme Filter
Lossnay Connectable
Long Life Filter High Efficiency Filter (Option) Filter Check SignalDeodorizing Filter
Design
Auto Front Panel
Suitable for 2 x 2 Ceiling(600 x 600mm)
Flat Panel Glossy Pure White Only 270mm in Height
Compact Size
Convenience
24-hour Timer
Wide Cooling Temperature Range
i save Mode
Auto Change Over
Weekly Timer (8 patterns/day×7 days)
Centralized On/Off Control M-NET Connection
Heating at -20˚C is possible
Auto Restart
New PAR-21MAA Connectable
Heating at -10˚C is possible
System (Group) Control is possible
Easy Maintenance Function
Simultaneous MultipleUnit Operation
Low Temperature Cooling
Installation & Maintenance
Quick Clean Body
Cleaning Free Pipe Reuse Easy Installationwith an Installation Plate
Self-Diagnosis Function
In/Out Separate Power SupplyReuse of Existing Wiring
MXZ Connectable Failure Recall Function
Corner Pocket for Maintenance Drain Water Lift Up Pump
120M Pipe Run 75M Pipe RunEasy & Simple Flare Connection
Anti Mold Drain Pan
Long-Length Piping
Mseries
26
-
27
Wall mounted Type Specifications
HEAT PUMP
Type
Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]
MSZ-FA25VA
MSZ-FA25VAMUZ-FA25VA
2.50.9 - 3.2
0.5954.20
A21 - 29 - 36 - 42
464.2 - 9.9
3.20.9 - 5.0
0.7354.35
A21 - 29 - 36 - 42
464.4 - 10.2
6.533
29878019810
55080028533
6.35 / 9.5220 / 12
-10 ~ +46-10 ~ +24
MSZ-FA25VAH
MSZ-FA25VAMUZ-FA25VAH
2.50.9 - 3.2
0.5954.20
A21 - 29 - 36 - 42
464.2 - 9.9
3.20.9 - 5.0
0.7354.35
A21 - 29 - 36 - 42
464.4 - 10.2
6.5332987801981055080028533
6.35 / 9.5220 / 12
-10 ~ +46-20 ~ +24
MSZ-FA35VA
MSZ-FA35VAMUZ-FA35VA
3.51.0 - 4.1
0.9353.74
A22 - 29 - 36 - 42
474.3 - 9.9
4.00.9 - 6.0
0.9954.02
A22 - 29 - 36 - 42
484.6 - 10.2
9.5332987801981055080028537
6.35 / 9.5220 / 12
-10 ~ +46-10 ~ +24
MSZ-FA35VAH
MSZ-FA35VAMUZ-FA35VAH
3.51.0 - 4.1
0.9353.74
A22 - 29 - 36 - 42
474.3 - 9.9
4.00.9 - 6.00.9954.02
A22 - 29 - 36 - 42
484.6 - 10.2
9.5332987801981055080028537
6.35 / 9.5220 / 12
-10 ~ +46-20 ~ +24
Inverter Heat Pump
MSZ-FAseries
Cooling
Heating
Max. Running Current
Indoor
Outdoor
Ext. Piping
Guaranteed Operating Range
[Outdoor]
Capacity
Total Input
EER
SPL
Air Volume
Capacity
Total Input
COP
SPL
Air Volume
Input
Dimensions
Weight
Dimensions
Weight
Diameter
Max. Length / Max. Height
RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High-SHi]*1
OUTIN [Low-SHi]*1
RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High-SHi]*1
OUTIN [Low-SHi]*1
RatedHeightWidthDepth
HeightWidthDepth
Liquid / Gas (φ)
CoolingHeating*1SHi: Super High
kWkWkW
dB(A) dB(A)m3/minkWkWkW
dB(A)dB(A)m3/min
AW
mmmmmmkg
mmmmmmkg
mmmoCoC
230, Single, 50, outdoor power supply
EER
ACOP
A
Outdoor Unit
Indoor Unit
RemoteController
MXZconnection
DCInverter
PAMControl Econo Cool
AUTOVANE Auto Panel Flat Panel
Auto Restart
Cooling at
46 C̊/-10 C̊
Quick CleanSelf
Diagnosis
FaliureRecall
Flareconnection20m
12m
AREAArea setting
GlossyWhite
24-hour Timer
ACO
SWING
HORIZONTAL
SWING
VERTICAL
WeeklyTimerOptional
CentralizedOn/Off
Optional
M-NETconnection
Optional
Only
21dBFA25
Heating at
-10̊COptional
Compact
Anti-Mold
VA
VAH
Heating at
-20̊C
28
Wall mounted Type Specifications
HEAT PUMP
Type
Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]
MSZ-GA22VA
MSZ-GA22VAN/A*2
-
-------
-----
0.333
298780210
9----
6.35 / 9.52---
MSZ-GA25VA
MSZ-GA25VAMUZ-GA25VA
2.50.9 - 3.0
0.643.91
A21 - 29 - 36 - 43
463.9 - 10.0
3.20.9 - 4.5
0.764.21
A21 - 29 - 36 - 43
464.3 - 10.5
5.533
298780210
955080028531
6.35 / 9.5220 / 12
-10 ~ +46-10 ~ +24
MSZ-GA25VAH
MSZ-GA25VAMUZ-GA25VAH
2.50.9 - 3.0
0.643.91
A21 - 29 - 36 - 43
463.9 - 10.0
3.20.9 - 4.5
0.764.21
A21 - 29 - 36 - 43
464.3 - 10.5
5.533
298780210
955080028531
6.35 / 9.5220 / 12
-10 ~ +46-20 ~ +24
MSZ-GA35VA
MSZ-GA35VAMUZ-GA35VA
3.51.0 - 3.9
1.083.24
A22 - 29 - 36 - 43
474.1 - 10.0
4.00.9 - 5.0
1.0553.79
A22 - 29 - 36 - 43
484.5 - 10.5
6.533
298780210
955080028533
6.35 / 9.5220 / 12
-10 ~ +46-10 ~ +24
MSZ-GA35VAH
MSZ-GA35VAMUZ-GA35VAH
3.51.0 - 3.9
1.083.24
A22 - 29 - 36 - 43
474.1 - 10.0
4.00.9 - 5.0
1.0553.79
A22 - 29 - 36 - 43
484.5 - 10.5
6.533
298780210
955080028533
6.35 / 9.5220 / 12
-10 ~ +46-20 ~ +24
Inverter Heat Pump
MSZ-GAseries
Cooling
Heating
Max. Running Current
Indoor
Outdoor
Ext. Piping
Guaranteed Operating Range
[Outdoor]
Capacity
Total Input
EER
SPL
Air Volume
Capacity
Total Input
COP
SPL
Air Volume
Input
Dimensions
Weight
Dimensions
Weight
Diameter
Max. Length / Max. Height
RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High-SHi]*1
OUTIN [Low-SHi]*1
RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High-SHi]*1
OUTIN [Low-SHi]*1
RatedHeightWidthDepth
HeightWidthDepth
Liquid / Gas (φ)
CoolingHeating*1SHi: Super High*2MSZ-GA22VA is for MXZ connection only.
kWkWkW
dB(A)dB(A)m3/minkWkWkW
dB(A)dB(A)m3/min
AW
mmmmmmkg
mmmmmmkg
mmmoCoC
230, Single, 50, outdoor power supply
EER
ACOP
A
Outdoor Unit
Indoor Unit
RemoteController
MXZconnection
DCInverter
PAMControl Econo Cool
AUTOVANE Flat Panel
Auto Restart
Cooling at
46 C̊/-10 C̊ Quick Clean
SelfDiagnosis
FaliureRecall
Flareconnection20m
12m
GlossyWhite
24-hour Timer
ACO
SWING
HORIZONTAL
WeeklyTimerOptional
CentralizedOn/Off
Optional
M-NETconnection
Optional
Only
21dBGA25
Heating at
-10̊COptional
Catechinas Standard filter Optional
Anti-AllergyEnzyme Compact
VA VAH
Heating at
-20̊C
-
Wall mounted Type Specifications
HEAT PUMP
Type
Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]
MSZ-GB50VA
MSZ-GB50VAMUZ-GB50VA
5.00.9 - 5.8
1.6503.03
B32 - 38 - 44 - 48(SHi)*
526.9 - 10.9(SHi)*
5.80.9 - 7.8
1.703.41
B30 - 36 - 42 - 48 (SHi)*
556.9 - 10.9 (SHi)*
1640298780210
985084033053
6.35 / 12.730 / 15
-10 ~ +43-10 ~ +24
MSZ-GA60VA
MSZ-GA60VAMUZ-GA60VA
6.00.9 - 6.7
1.933.11
B32 - 40 - 54
538.7 - 17.2
6.80.9 - 8.1
1.943.51
B32 - 40 - 54
558.7 - 17.2
1660325
1,1002581685084033053
6.35 / 15.8830 / 15
-10 ~ +43-10 ~ +24
MSZ-GA71VA
MSZ-GA71VAMUZ-GA71VA
7.10.9 - 8.3
2.422.93
C33 - 40 - 54
539.4 - 17.2
8.10.9 - 9.6
2.453.31
C33 - 40 - 54
559.4 - 17.2
1660325
1,1002581685084033058
9.52 / 15.8830 / 15
-10 ~ +43-10 ~ +24
Inverter Heat Pump
MSZ-GA/GBseries
Cooling
Heating
Max. Running Current
Indoor
Outdoor
Ext. Piping
Guaranteed Operating Range
[Outdoor]
Capacity
Total Input
EER
SPL
Air Volume
Capacity
Total Input
COP
SPL
Air Volume
Input
Dimensions
Weight
Dimensions
Weight
Diameter
Max. Length / Max. Height
RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High]OUTIN [Low-High]RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High]OUTIN [Low-High]
RatedHeightWidthDepth
HeightWidthDepth
Liquid / Gas (φ)
CoolingHeating
kWkWkW
dB(A)dB(A)m3/minkWkWkW
dB(A)dB(A)m3/min
AW
mmmmmmkg
mmmmmmkg
mmmoCoC
230, Single, 50, outdoor power supply
Outdoor Unit
Indoor Unit
RemoteController
29
* SHi: Super High
MXZconnection
FaliureRecall
Flareconnection30m
15m
SWING
GA60/71
DCInverter
PAMControl Econo Cool
AUTOVANE Flat Panel
SWING
HORIZONTAL GA60/71 GA60/71
Catechinas Standard filter Optional GB50
Anti-AllergyEnzymeWide Long
Auto RestartSelf
Diagnosis
GlossyWhite
24-hour TimerGB50
ACOWeekly
TimerOptional
CentralizedOn/Off
Optional
M-NETconnection
OptionalOptional
Cooling at
-10̊CHeating at
-10̊C
MSZ-GB50
MSZ-GA60/71
30
Wall mounted Type Specifications
HEAT PUMP
Type
Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]
MSZ-HA25VA
MSZ-HA25VAMUZ-HA25VA
2.50.9 - 3.0
0.7853.18
B26 - 43
465.3 - 10.5
3.20.9 - 4.4
0.9453.39
C26 - 43
465.1 - 11.0
5.523
295788225
955080028531
6.35 / 9.5210 / 5
+18 ~ +43-10 ~ +24
MSZ-HA35VA
MSZ-HA35VAMUZ-HA35VA
3.151.0 - 3.7
1.0453.01
B26 - 43
475.3 - 10.5
3.60.9 - 4.8
1.073.36
C26 - 43
485.1 - 11.0
6.523
295788225
955080028533
6.35 / 9.5210 / 5
+18 ~ +43-10 ~ +24
Inverter Heat Pump
MSZ-HAseries
Cooling
Heating
Max. Running Current
Indoor
Outdoor
Ext. Piping
Guaranteed Operating Range
[Outdoor]
Capacity
Total Input
EER
SPL
Air Volume
Capacity
Total Input
COP
SPL
Air Volume
Input
Dimensions
Weight
Dimensions
Weight
Diameter
Max. Length / Max. Height
RatedMin - MaxRated
EEL Rank
IN [Low-SHi]OUTIN [Low-SHi]RatedMin - MaxRated
EEL Rank
IN [Low-SHi]OUTIN [Low-SHi]
RatedHeightWidthDepth
HeightWidthDepth
Liquid / Gas
CoolingHeating
kWkWkW
dB(A)dB(A)m3/minkWkWkW
dB(A)dB(A)m3/min
AW
mmmmmmkg
mmmmmmkg
mmmoCoC
230, Single, 50, outdoor power supply
Outdoor Unit
Indoor Unit
RemoteController
* SHi : Super High
DCInverter Econo Cool
AUTOVANE Flat Panel
Flareconnection10m
5m
Only
26dBHeating at
-10̊CCatechinOptionalHORIZONTAL HORIZONTAL
CompactVA12-hour Timer
12
SWING GlossyWhite
-
Wall mounted Type Specifications
HEAT PUMP
Type
Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]
MSH-GA20VB
MSC-GA20VBMUH-GA20VB
2.3-
0.7153.22
A25 - 31 - 36
477.92.5
-0.693.62
A25 - 31 - 36
478.55.735
278815244
955080028529
6.35 / 9.5220 / 10
+21 ~ +43-10 ~ +24
MSH-GA25VB
MSC-GA25VBMUH-GA25VB
2.65-
0.823.23
A25 - 31 - 36
497.93.0
-0.823.66
A25 - 32 - 39
499.86.135
278815244
955080028530
6.35 / 9.5220 / 10
+21 ~ +43-10 ~ +24
MSH-GA35VB
MSC-GA35VBMUH-GA35VB
3.5-
1.093.21
A26 - 33 - 40
499.73.7
-1.023.63
A26 - 33 - 39
4910.17.740
27881524410
55080028535
6.35 / 9.5225 / 10
+21 ~ +43-10 ~ +24
Fixed-Speed Heat Pump
MSH-GAseries
Cooling
Heating
Max. Running Current
Indoor
Outdoor
Ext. Piping
Guaranteed Operating Range
[Outdoor]
Capacity
Total Input
EER
SPL
Air Volume
Capacity
Total Input
COP
SPL
Air Volume
Input
Dimensions
Weight
Dimensions
Weight
Diameter
Max. Length / Max. Height
RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High]OUTIN [High]RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High]OUTIN [High]
RatedHeightWidthDepth
HeightWidthDepth
Liquid / Gas (φ)
CoolingHeating
kWkWkW
dB(A)dB(A)m3/minkWkWkW
dB(A)dB(A)m3/min
AW
mmmmmmkg
mmmmmmkg
mmmoCoC
230, Single, 50, indoor/outdoor separate power supply
COP
AEER
A
32
SelfDiagnosis
MXZconnection
Flareconnection
MXZ-A14/18WV
20m10m
GA20/25
25m10m
GA35
Econo CoolAUTOVANE Auto Restart
GlossyWhite
24-hour Timer
SWING
HORIZONTAL
I FEEL
Flat PanelCompact
Catechinas Standard filter
Air-CleaningOptional
Outdoor Unit
Indoor Unit
RemoteController
Wall mounted Type Specifications
HEAT PUMP
Type
Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]
MSZ-CB22VA
MSZ-CB22VAN/A*2
-
-------
-----
0.333298780210
9----
6.35 / 9.52---
MSZ-CB35VA
MSZ-CB35VAMUZ-GA35VA
3.51.0 - 3.9
1.083.24
A22 - 29 - 36 - 43
474.1 - 10.0
4.00.9 - 5.0
1.0553.79
A22 - 29 - 36 - 43
484.5 - 10.5
6.533298780210
955080028533
6.35 / 9.5220 / 12
-10 ~ +46-10 ~ +24
Inverter Heat Pump
MSZ-CBseries
Cooling
Heating
Max. Running Current
Indoor
Outdoor
Ext. Piping
Guaranteed Operating Range
[Outdoor]
Capacity
Total Input
EER
SPL
Air Volume
Capacity
Total Input
COP
SPL
Air Volume
Input
Dimensions
Weight
Dimensions
Weight
Diameter
Max. Length / Max. Height
RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High-SHi*1]OUTIN [Low-SHi*1]RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High-SHi*1]OUTIN [Low-SHi*1]
RatedHeightWidthDepth
HeightWidthDepth
Liquid / Gas (φ)
CoolingHeating
kWkWkW
dB(A)dB(A)m3/minkWkWkW
dB(A)dB(A)m3/min
AW
mmmmmmkg
mmmmmmkg
mmmoCoC *1SHi: Super High *2MSZ-CB22VA is for MXZ connection only.
230, Single, 50, outdoor power supply
EER
ACOP
A
31
MSZ-CB25VA
MSZ-CB25VAMUZ-GA25VA
2.50.9 - 3.0
0.643.91
A21 - 29 - 36 - 43
463.9 - 10.0
3.20.9 - 4.5
0.764.21
A21 - 29 - 36 -43
464.3 - 10.5
5.533298780210
955080028531
6.35 / 9.5220 / 12
-10 ~ +46-10 ~ +24
MXZconnection
DCInverter
PAMControl Econo Cool
AUTOVANE Flat Panel
Auto Restart
Cooling at
46 C̊/-10 C̊ Quick Clean SelfDiagnosis
FaliureRecall
Flareconnection20m
12m
GlossyWhite
24-hour Timer
ACO
SWING
HORIZONTAL
WeeklyTimerOptional
CentralizedOn/Off
Optional
M-NETconnection
Optional
Only
21dBCB25
Heating at
-10̊COptional
Catechinas Standard filter Optional
Anti-AllergyEnzyme Compact
Outdoor Unit
Indoor Unit
RemoteController
-
Wall mounted Type Specifications
Cooling Only
Type
Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]
MS-GA20VB
MSC-GA20VBMU-GA20VB
2.3-
0.7153.22
A25 - 31 - 36
457.9
--------
5.735
278815244
955080028527
6.35 / 9.5220 / 10
+21 ~ +43-
MS-GA25VB
MSC-GA25VBMU-GA25VB
2.5-
0.7753.23
A25 - 31 - 36
457.9
--------
5.635
278815244
955080028527
6.35 / 9.5220 / 10
+21 ~ +43-
MS-GA35VB
MSC-GA35VBMU-GA35VB
3.45-
1.123.08
B26 - 33 - 40
499.7
--------
8.340
27881524410
55080028530
6.35 / 9.5225 / 10
+21 ~ +43-
Fixed-Speed Cooling Only
MS-GAseries
Cooling
Heating
Max. Running Current
Indoor
Outdoor
Ext. Piping
Guaranteed Operating Range
[Outdoor]
Capacity
Total Input
EER
SPL
Air Volume
Capacity
Total Input
COP
SPL
Air Volume
Input
Dimensions
Weight
Dimensions
Weight
Diameter
Max. Length / Max. Height
RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High]OUTIN [High]RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High]OUTIN [High]
RatedHeightWidthDepth
HeightWidthDepth
Liquid / Gas (φ)
CoolingHeating
kWkWkW
dB(A)dB(A)m3/minkWkWkW
dB(A)dB(A)m3/min
AW
mmmmmmkg
mmmmmmkg
mmmoCoC
230, Single, 50, indoor/outdoor separate power supply
EER
AGA20/25
34
SelfDiagnosis
MXZconnection
Flareconnection
MXZ-A14/18WV
20m10m
GA20/25
25m10m
GA35
Catechinas Standard filter
Econo CoolAUTOVANE Auto Restart
GlossyWhite
24-hour Timer
SWING
HORIZONTAL
I FEEL
Air-CleaningOptional
Flat PanelCompact
Outdoor Unit
Indoor Unit
RemoteController
Wall mounted Type Specifications
HEAT PUMP
Type
Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]
MSH-GA50VB
MSH-GA50VBMUH-GA50VB
5.0-
1.782.81
C34 - 38 - 42
5212.85.2
-1.613.23
C34 - 38 - 42
5212.812.960325
1,1002581660585029047
6.35 / 12.725 / 10
+21 ~ +43-10 ~ +24
MSH-GA60VB
MSH-GA60VBMUH-GA60VB
6.3-
2.412.61
D37 - 41 - 45
5312.87.2
-2.482.90
D34 - 41 - 45
5312.816.560325
1,1002581685084033074
6.35 / 15.8825 / 10
+21 ~ +43-10 ~ +24
MSH-GA80VB
MSH-GA80VBMUH-GA80VB
8.5-
3.262.61
D37 - 42 - 47
5515.99.4
-3.432.74
E37 - 42 - 47
5515.922.969325
1,1002581685084033077
9.52 / 15.8830 / 15
+21 ~ +43-10 ~ +24
Fixed-Speed Heat Pump
MSH-GAseries
Cooling
Heating
Max. Running Current
Indoor
Outdoor
Ext. Piping
Guaranteed Operating Range
[Outdoor]
Capacity
Total Input
EER
SPL
Air Volume
Capacity
Total Input
COP
SPL
Air Volume
Input
Dimensions
Weight
Dimensions
Weight
Diameter
Max. Length / Max. Height
RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High]OUTIN [High]RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High]OUTIN [High]
RatedHeightWidthDepth
HeightWidthDepth
Liquid / Gas (φ)
CoolingHeating
kWkWkW
dB(A)dB(A)m3/minkWkWkW
dB(A)dB(A)m3/min
AW
mmmmmmkg
mmmmmmkg
mmmoCoC
230, Single, 50, indoor/outdoor separate power supply
MUH-GA50VB MUH-GA60/80VB
33
Catechinas Standard filter
Econo Cool
Auto RestartSelf
Diagnosis
Flareconnection
GlossyWhite
24-hour Timer
I FEEL
Air-CleaningOptional
Flat Panel
25m10m
GA50/60
30m15m
GA80
AUTOVANE
SWING
HORIZONTAL
SWING
VERTICAL
Wide Long
Outdoor Unit
Indoor Unit
RemoteController
-
Wall mounted Type Specifications
HEAT PUMP
Type
Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]
MSH-CB20VB
MSC-CB20VBMUH-GA20VB
2.3-
0.7153.22
A25 - 31 - 36
477.92.5
-0.693.62
A25 - 31 - 36
478.55.735
278815244
955080028529
6.35 / 9.5220 / 10
+21 ~ +43-10 ~ +24
MSH-CB25VB
MSC-CB25VBMUH-GA25VB
2.65-
0.823.23
A25 - 31 - 36
497.93.0
-0.823.66
A25 - 32 - 39
499.86.135
278815244
955080028530
6.35 / 9.5220 / 10
+21 ~ +43-10 ~ +24
MSH-CB35VB
MSC-CB35VBMUH-GA35VB
3.5-
1.093.21
A26 - 33 - 40
499.73.7
-1.023.63
A26 - 33 - 39
4910.17.740
27881524410
55080028535
6.35 / 9.5225 / 10
+21 ~ +43-10 ~ +24
MSH-CB50VB
MSH-CB50VBMUH-GA50VB
5.0-
1.782.81
C34 - 38 - 42
5212.85.2
-1.613.23
C34 - 38 - 42
5212.812.960
3251,10025816
60585029047
6.35 / 12.725 / 10
+21 ~ +43-10 ~ +24
Fixed-Speed Heat Pump
MSH-CBseries
Cooling
Heating
Max. Running Current
Indoor
Outdoor
Ext. Piping
Guaranteed Operating Range
[Outdoor]
Capacity
Total Input
EER
SPL
Air Volume
Capacity
Total Input
COP
SPL
Air Volume
Input
Dimensions
Weight
Dimensions
Weight
Diameter
Max. Length / Max. Height
RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High]OUTIN [High]RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High]OUTIN [High]
RatedHeightWidthDepth
HeightWidthDepth
Liquid / Gas (φ)
CoolingHeating
kWkWkW
dB(A)dB(A)m3/minkWkWkW
dB(A)dB(A)m3/min
AW
mmmmmmkg
mmmmmmkg
mmmoCoC
230, Single, 50, indoor/outdoor separate power supply
MUH-GA20/25/35VB MUH-GA50VB
EER
ACB20/25/35
COP
ACB20/25/35
36
SelfDiagnosis
MXZconnection
Flareconnection
MXZ-A14/18WV
20m10m
GA20/25
25m10m
GA35
Catechinas Standard filter
Econo CoolAUTOVANE Auto Restart
GlossyWhite
24-hour Timer
SWING
HORIZONTAL
I FEEL
Air-CleaningOptional
Flat PanelCompact
Outdoor Unit
Indoor Unit
RemoteController
MSH-CB20/25/35VB
MSH-CB50VB
Wall mounted Type Specifications
Type
Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]
MS-GA50VB
MS-GA50VBMU-GA50VB
5.0-
1.812.76
D34 - 38 - 42
5212.8
--------
13.260325
1,1002581660585029044
6.35 / 12.725 / 10
+21 ~ +43-
MS-GA60VB
MS-GA60VBMU-GA60VB
6.5-
2.482.62
D37 - 41 - 45
5312.8
--------
16.960325
1,1002581660585029060
6.35 / 15.8825 / 10
+21 ~ +43-
MS-GA80VB
MS-GA80VBMU-GA80VB
8.5-
3.262.61
D37 - 42 - 47
5515.9
--------
22.669325
1,1002581685084033075
9.52 / 15.8830 / 15
+21 ~ +43-
Fixed-Speed Cooling Only
MS-GAseries
Cooling
Heating
Max. Running Current
Indoor
Outdoor
Ext. Piping
Guaranteed Operating Range
[Outdoor]
Capacity
Total Input
EER
SPL
Air Volume
Capacity
Total Input
COP
SPL
Air Volume
Input
Dimensions
Weight
Dimensions
Weight
Diameter
Max. Length / Max. Height
RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High]OUTIN [High]RatedMin - MaxRated
EEL Rank
IN [Low-Mid-High]OUTIN [High]
RatedHeightWidthDepth
HeightWidthDepth
Liquid / Gas (φ)
CoolingHeating
kWkWkW
dB(A)dB(A)m3/minkWkWkW
dB(A)dB(A)m3/min
AW
mmmmmmkg
mmmmmmkg
mmmoCoC
230, Single, 50, indoor/outdoor separate power supply
Cooling Only
MU-GA50/60VB MU-GA80VB
35
Auto RestartSelf
Diagnosis
Flareconnection
24-hour Timer
25m10m
GA50/60
30m15m
GA80
Catechinas Standard filter
Econo CoolAUTOVANE
GlossyWhite
SWING
HORIZONTAL
I FEEL
Air-CleaningOptional
Flat Panel
SWING
VERTICAL
Wide Long
Outdoor Unit
Indoor Unit
RemoteController
-
Two-way Floor Standing and Ceiling suspended Type Specifications
HEAT PUMP
Type
Model NameIndoor Unit Outdoor UnitPower Supply [V, Phase, Hz, Source]
MCFH-GA35VB
MCFH-GA35VBM