Purpose

Heating Only

Heating & Cooling

Cooling Only

Type Temp Range

Selecting the Right Equipment

John Morris Scientific offers an extensive range of temperature control equipment to meet your individual requirements.

The following pages list basic product specifications (eg temperature range, heating/cooling capacity, fill volume, flow rate, pump pressure, etc) separately for Heating Only, Heating & Cooling and Cooling Only equipment - providing an overview of the range offered.

However, to ensure you select the right equipment for your particular application process, specific additional information is required - for example:

Maintain or Control Temperature: Do you want to keep the temperature stable/constant or do you want to adjust the temperature throughout the process?

Rapid Heating/Cooling: How quickly do you want to heat or cool or both (eg heat 10ᵒC an hour or 1ᵒC per minute)?

Monitoring: How do you want to monitor the results, do you want to know what’s happening throughout the process (and do you want to record data and how), do you want an alarm (for when a set temperature is reached or another purpose)?

Type of Material: What is the type and mass of the material solution to be heated or cooled or both?

The answers to these and other questions will ensure you select the right equipment for your particular demands.

To ensure you select the right temperaure control equipment for your needs, simply contact John Morris Scientific for professional assistance.

Heating Immersion Circulators +20ᵒC to +300ᵒCOpen Heating Bath Circulators +20ᵒC to +150ᵒCHeating Circulators +20ᵒC to +300ᵒCForte HT Highly Dynamic Temp Control Systems +40ᵒC to +400ᵒCWater Baths +20ᵒC to +99.9ᵒCRefrigerated/Heating Circulators -50ᵒC to +200ᵒCUltra Low Refrigerated Circulators -95ᵒC to +200ᵒCPresto Highly Dynamic Temp Control Systems -92ᵒC to +250ᵒCRecirculating Coolers -25ᵒC to +80ᵒCCalibration Baths -38ᵒC to +300ᵒCCryo-Compact Circulators -40ᵒC to +200ᵒCRecirculating Coolers -25ᵒC to +40ᵒCImmersion Coolers -90ᵒC to +30ᵒCRefrigerators for Chemicals -2ᵒC to +12ᵒC

Immersion Circulator (EH)

Open Heating Bath Circulator (ED-19A)

Heating Circulator (MA-26)

Open Heating Bath Circulator (ED-33)

Water Bath (TW20)

Images of Heating Only Equipment

Page 3: Julabo temp control summary nz

Toll Free: 0800 651 700 3 www.jms.co.nz

Very flexible for a variety of bath tanks plus suitable for a wide range

of applications (eg temperature applications for samples, analytics,

material testing)

Temperature applications for preparation of samples (serology & clinical chemistry), analytics, material testing, life sciences,

agriculture & other diverse applications

Temperature applications for preparation of samples (serology

& clinical chemistry), analytics, material testing, external temperature control (with measuring instruments),

measuring cells, photometers, refractometers, polarimeters

External temperature application in combination with jacketed

reactors, distillation apparatus, mini-plant applications,

photometers, refractometers & temperature applications to

small objects

Designed for high temperature control in closed external systems

Routine applications (eg cell cultivation), temperature control of samples, incubation, corrosion tests,

test food & beverages

Biochemical, enzyme & tissue studies, homogenisation, fermentation,

incubation, blood plasma thawing, test food & beverages

Immersion Circulators

Open Heating

Bath Circulators

Heating Circulators

Forte Highly

Dynamic Control Systems

Water Baths

ED +20ᵒto+100ᵒC 2 - 15 0.35 13-15-33 3.3EH +20ᵒto+150ᵒC 2 - 15 0.35 13-15-33 3.3MB +20ᵒto+100ᵒC 2 - 10 0.12 13-15-33 3.3MA +20ᵒto+200ᵒC 2 - 11-16 0.23-0.45 13-15-33 4ME +20ᵒto+200ᵒC 2 - 11-16 0.23-0.45 13-15-33 4SE-Z +20ᵒto+300ᵒC 3 - 22-26 0.4-0.7 32-17-40 8ED-5A/B +20ᵒto+60ᵒC 2 5 15 0.35 14-40-35 5.3ED-7A/B +20ᵒto+60ᵒC 2 7 15 0.35 14-50-35 5.6ED-5M/B +20ᵒto+60ᵒC 2 5 15 0.35 14-40-35 5.2ED-13A +20ᵒto+100ᵒC 2 13 15 0.35 41-33-36 7.5ED-19A +20ᵒto+60ᵒC 2 19 15 0.35 55-33-36 8.5ED-13M +20ᵒto+100ᵒC 2 13 15 0.35 41-33-37 7.5ED-19M +20ᵒto+100ᵒC 2 19 15 0.35 55-33-37 8.5MB-13A +20ᵒto+60ᵒC 2 13 10 0.12 41-33-36 7.5MB-19A +20ᵒto+60ᵒC 2 19 10 0.12 55-33-36 8.5ED-13 +20ᵒto+100ᵒC 2 13 15 0.35 39-33-37 8ED-17 +20ᵒto+100ᵒC 2 17 15 0.35 39-33-42 10ED-19 +20ᵒto+100ᵒC 2 19 15 0.35 57-33-37 11ED-27 +20ᵒto+100ᵒC 2 27 15 0.35 57-37-42 13ED-33 +20ᵒto+100ᵒC 2 33 15 0.35 91-33-38 20MB-13 +20ᵒto+100ᵒC 2 13 10 0.12 39-33-37 8MB-19 +20ᵒto+100ᵒC 2 19 10 0.12 57-33-37 11ED-5A +20ᵒto+60ᵒC 2 5 15 0.35 14-40-35 5.3ED-5M +20ᵒto+100ᵒC 2 5 15 0.35 14-40-35 5.2MB-5A +20ᵒto+60ᵒC 2 5 10 0.12 14-40-35 5.3MB-7A +20ᵒto+60ᵒC 2 7 10 0.12 14-50-35 5.6MB-5M +20ᵒto+100ᵒC 2 5 10 0.12 14-40-35 5.2ED-5 +20ᵒto+100ᵒC 2 4.5 15 0.35 17-33-36 7EH-5 +20ᵒto+150ᵒC 2 4.5 15 0.35 17-33-36 7EH-13 +20ᵒto+150ᵒC 2 13 15 0.35 39-33-37 8EH-19 +20ᵒto+150ᵒC 2 19 15 0.35 57-33-37 11EH-27 +20ᵒto+150ᵒC 2 27 15 0.35 57-37-42 13EH-33 +20ᵒto+150ᵒC 2 33 15 0.35 91-33-38 20EH-39 +20ᵒto+150ᵒC 2 39 15 0.35 54-34-52 19MB-5 +20ᵒto+100ᵒC 2 4.5 10 0.12 17-33-36 7MA-4 +20ᵒto+200ᵒC 2 4.5 11-16 0.23-0.45 21-42-38 9.6MA-6 +20ᵒto+200ᵒC 2 6 11-16 0.23-0.45 21-43-42 12.5MA-12 +20ᵒto+200ᵒC 2 12 11-16 0.23-0.45 30-43-45 13MA-26 +20ᵒto+200ᵒC 2 26 11-16 0.23-0.45 36-61-45 26ME-4 +20ᵒto+200ᵒC 2 4.5 11-16 0.23-0.45 21-42-38 9.6ME-6 +20ᵒto+200ᵒC 2 6 11-16 0.23-0.45 21-43-42 12.5ME-12 +20ᵒto+200ᵒC 2 12 11-16 0.23-0.45 30-43-45 13ME-26 +20ᵒto+200ᵒC 2 26 11-16 0.23-0.45 36-61-45 26HE-4 +20ᵒto+250ᵒC 2 4.5 22-26 0.4-0.7 21-42-40 11SE-6 +20ᵒto+300ᵒC 3 6 22-26 0.4-0.7 21-43-44 13.5SE-12 +20ᵒto+300ᵒC 3 12 22-26 0.4-0.7 30-43-47 14SE-26 +20ᵒto+300ᵒC 3 26 22-26 0.4-0.7 36-61-47 27HL-4 +20ᵒto+250ᵒC 2 4.5 22-26 0.4-0.7 21-42-40 11SL-6 +20ᵒto+300ᵒC 3 6 22-26 0.4-0.7 21-43-44 13.5SL-12 +20ᵒto+300ᵒC 3 12 22-26 0.4-0.7 30-43-47 14SL-26 +20ᵒto+300ᵒC 3 26 22-26 0.4-0.7 36-61-47 27HT30-M1 +70ᵒto+400ᵒC 3 2 14-18 0.8-1.2 25-25-18 27HT60-M2 +70ᵒto+400ᵒC 7 2 14-18 0.8-1.2 25-25-18 29HT60-M3 +70ᵒto+400ᵒC 6 2 14-18 0.8-1.2 25-25-18 29HT30-M1-C.U +40ᵒto+400ᵒC 3 2 14-18 0.8-1.2 25-25-18 35HT60-M2-C.U +40ᵒto+400ᵒC 7 2 14-18 0.8-1.2 25-25-18 37HT60-M3-C.U +40ᵒto+400ᵒC 6 2 14-18 0.8-1.2 25-25-18 37TW2 +20ᵒto+99.9ᵒC 1 1-2 - - 17-16-37 3.5TW8 +20ᵒto+99.9ᵒC 2 3-8 - - 29-32-44 8.5TW12 +20ᵒto+99.9ᵒC 2 5-14 - - 40-32-44 9.8TW20 +20ᵒto+99.9ᵒC 2 8-26 - - 56-35-49 14.2SW22 +20ᵒto+99.9ᵒC 2 8-20 - - 70-35-43 19.4SW23 +20ᵒto+99.9ᵒC 2 8-20 - - 70-35-43 21.4

Type Model Temp Range Heating Capacity (kW)

Fill Volume (L)

Flow Rate (L/min)

Size (cm)W-L-H

Weight(kg)

Application Examples

Pump Pressure (bar)

Heating Only Equipment

Page 4: Julabo temp control summary nz

Toll Free: 0800 651 700 4 www.jms.co.nz

Scientific

JohnMorris John Morris Scientific

Service plus Solutions

Type

Refrigerated /Heating

Circulators

Ultra-Low Refrigerated Circulators

Model Temp Range Application Examples

Fill Volume (L)

Heating Capacity

(kW)

Cooling Capacity at 20ᵒC

(kW)Flow Rate

(L/min)Size (cm)

W-L-HWeight

(kg)Pump

Pressure (bar)

Routine applications (eg immersing samples for temperature studies

in the circulator baths) plus external temperature control

applications (eg measuring cells, refractometers, polarimeters,

photometers, viscometers, fermenters, electrophoresis chambers, chromatography columns, rotary evaporators,

Rheometers)

Designed for more demanding applications & feature increased

functionality plus additional warning & safety functions

For a wide range of applications - units have a connection for

external Pt100 sensor for direct measuring & control (VFD

Comfort display features easy operation & shows all temperature

values on one display)

External temperature control applications, particularly for

distillation apparatus & mini-plant installations, jacketed reactors,

autoclaves, Kilo labs, pilot plants

Freezing point determination, calibration at low temperatures,

Petroleum testing, ultra-low temperature cell culture storage

Jacketed reactors, mini-plants, Kilo labs, process development

Heating & Cooling Equipment

F12-ED -20 oto+100ᵒC 0.16 2 4.5 15 0.35 20-36-56 22F25-ED -28 oto+100ᵒC 0.26 2 4.5 15 0.35 23-42-61 30F26-ED -28 oto+100ᵒC 0.26 2 4.5 15 0.35 42-42-42 30F34-ED -30 oto+100ᵒC 0.45 2 20 15 0.35 38-58-62 41F12-EH -20 oto+150ᵒC 0.16 2 4.5 15 0.35 20-36-56 22F25-EH -28 oto+150ᵒC 0.26 2 4.5 15 0.35 23-42-61 30FN25-EH -28 oto+150ᵒC 0.26 2 4.5 15 0.35 23-50-61 31F32-EH -35 oto+150ᵒC 0.45 2 8 15 0.35 31-42-64 36FN32-EH -35 oto+150ᵒC 0.45 2 8 15 0.35 31-50-64 37F33-EH -30 oto+150ᵒC 0.50 2 16 15 0.35 36-46-69 43F34-EH -30 oto+150ᵒC 0.45 2 20 15 0.35 38-58-62 41F38-EH -35 oto+80ᵒC 0.92 2 45 15 0.35 46-70-89 67F12-MA -20 oto+200ᵒC 0.16 2 4.5 11-16 0.23-0.45 20-36-56 23F25-MA -28 oto+200ᵒC 0.26 2 4.5 11-16 0.23-0.45 23-42-61 31FN25-MA -28 oto+200ᵒC 0.26 2 4.5 11-16 0.23-0.45 23-50-61 32F32-MA -35 oto+200ᵒC 0.45 2 8 11-16 0.23-0.45 31-42-64 37FN32-MA -35 oto+200ᵒC 0.45 2 8 11-16 0.23-0.45 31-50-64 38F33-MA -30 oto+200ᵒC 0.50 2 16 11-16 0.23-0.45 36-46-69 44F34-MA -30 oto+150ᵒC 0.45 2 20 11-16 0.23-0.45 38-58-62 42FP35-MA -35 oto+150ᵒC 0.45 2 2.5 11-16 0.23-0.45 31-42-64 37FP40-MA -40 oto+200ᵒC 0.68 2 16 11-16 0.23-0.45 37-46-69 48FP50-MA -50 oto+200ᵒC 0.90 2 8 11-16 0.23-0.45 42-49-70 55FPW50-MA -50 oto+200ᵒC 0.90 2 8 11-16 0.23-0.45 42-49-70 55F25-ME -28 oto+200ᵒC 0.26 2 4.5 11-16 0.23-0.45 23-42-61 31FN25-ME -28 oto+200ᵒC 0.26 2 4.5 11-16 0.23-0.45 23-50-61 32F26-ME -28 oto+200ᵒC 0.26 2 4.5 11-16 0.23-0.45 42-42-42 31F32-ME -35 oto+200ᵒC 0.45 2 8 11-16 0.23-0.45 31-42-64 37FN32-ME -35 oto+200ᵒC 0.45 2 8 11-16 0.23-0.45 31-50-64 38F33-ME -30 oto+200ᵒC 0.50 2 16 11-16 0.23-0.45 36-46-69 44F34-ME -30 oto+150ᵒC 0.45 2 20 11-16 0.23-0.45 38-58-62 42FP40-ME -40 oto+200ᵒC 0.68 2 16 11-16 0.23-0.45 37-46-69 48FP50-ME -50 oto+200ᵒC 0.90 2 8 11-16 0.23-0.45 42-49-70 55FPW50-ME -50 oto+200ᵒC 0.90 2 8 11-16 0.23-0.45 42-49-70 55F25-HE -28 oto+200ᵒC 0.26 2 4.5 22-26 0.4-0.7 23-42-64 32FN25-HE -28 oto+200ᵒC 0.26 2 4.5 22-26 0.4-0.7 23-50-64 33F32-HE -35 oto+200ᵒC 0.45 2 8 22-26 0.4-0.7 31-42-66 38FN32-HE -35 oto+200ᵒC 0.45 2 8 22-26 0.4-0.7 31-50-66 39F34-HE -30 oto+150ᵒC 0.45 2 20 22-26 0.4-0.7 38-58-64 44FP40-HE -40 oto+200ᵒC 0.68 2 16 22-26 0.4-0.7 37-46-71 49FP45-HE -42 oto+200ᵒC 0.85 2 26 22-26 0.4-0.7 38-58-69 53FP50-HE -50 oto+200ᵒC 0.90 2 8 22-26 0.4-0.7 42-49-72 57FPW50-HE -50 oto+200ᵒC 0.90 2 8 22-26 0.4-0.7 42-49-72 57F25-HL -28 oto+200ᵒC 0.26 2 4.5 22-26 0.4-0.7 23-42-64 32FN25-HL -28 oto+200ᵒC 0.26 2 4.5 22-26 0.4-0.7 23-50-64 33F32-HL -35 oto+200ᵒC 0.45 2 8 22-26 0.4-0.7 31-42-66 38FN32-HL -35 oto+200ᵒC 0.45 2 8 22-26 0.4-0.7 31-50-66 39F33-HL -30 oto+200ᵒC 0.50 2 16 22-26 0.4-0.7 36-46-71 45FP35-HL -35 oto+150ᵒC 0.45 2 2.5 22-26 0.4-0.7 31-42-66 38FP40-HL -40 oto+200ᵒC 0.68 2 16 22-26 0.4-0.7 37-46-71 49FP45-HL -42 oto+200ᵒC 0.85 2 26 22-26 0.4-0.7 38-58-59 53FP50-HL -50 oto+200ᵒC 0.90 2 8 22-26 0.4-0.7 42-49-72 57FPW50-HL -50 oto+200ᵒC 0.90 2 8 22-26 0.4-0.7 42-49-72 57F70-ME -70 oto+100ᵒC 0.34 1.3 4.5 11-16 0.23-0.45 42-54-71 63F81-ME -81 oto+100ᵒC 0.45 1.3 6.5 11-16 0.23-0.45 50-58-88 86FP89-ME -90 oto+100ᵒC 1.0 1.3 8 11-16 0.23-0.45 55-60-90 133FP51-SL -51 oto+200ᵒC 2.0 3 11 22-26 0.4-0.7 46-55-89 90FP52-SL -60 oto+100ᵒC 3.0 3 24 22-26 0.4-0.7 59-76-116 156FP55-SL -60 oto+100ᵒC 5.2 3 27 22-26 0.4-0.7 85-76-116 182F81-HL -81 oto+100ᵒC 0.45 1.3 6.5 22-26 0.4-0.7 50-58-89 88FP89-HL -90 oto+100ᵒC 1.0 1.3 8 22-26 0.4-0.7 55-60-92 135FP90-SL -90 oto+100ᵒC 1.8 3 22 22-26 0.4-0.7 59-76-116 195FPW52-SL -60 oto+100ᵒC 3.0 3 24 22-26 0.4-0.7 59-76-116 153FPW55-SL -60 oto+100ᵒC 5.5 3 27 22-26 0.4-0.7 59-76-116 163FPW90-SL -90 oto+100ᵒC 1.8 3 22 22-26 0.4-0.7 59-76-116 188FPW91-SL -91 oto+100ᵒC 4.5 3 22 22-26 0.4-0.7 85-76-116 296F95-SL -95 oto0ᵒC - 3 22 22-26 0.4-0.7 59-76-116 201FW95-SL -95 oto0ᵒC - 3 22 22-26 0.4-0.7 59-76-116 198

Page 5: Julabo temp control summary nz

Toll Free: 0800 651 700 5 www.jms.co.nz

Refrigerated/Heated Circulator (F12-ED)

Refrigerated/Heated Circulator (F25-MA)

Presto Highly Dynamic (A40)

Ultra-Low Circulator (FP52-SL)

Recirculating Cooler (SC2500a)

Images of Heating & Cooling Equipment

Heating & Cooling Equipment

A30 -30 oto+250ᵒC 0.5 2.7 - 25 0.5 25-59-62 62A40 -40 oto+250ᵒC 1.2 2.7 - 16-40 0.3-1.7 33-59-67 79W40 -40 oto+250ᵒC 1.2 2.7 - 16-40 0.3-1.7 33-59-67 78A80 -80 oto+250ᵒC 1.2 1.8 - 16-40 0.3-1.7 43-65-126 164A80t -80 oto+250ᵒC 1.2 3.4 - 16-40 0.3-1.7 43-65-126 167W80 -80 oto+250ᵒC 1.2 1.8 - 16-40 0.3-1.7 43-65-126 159W80t -80 oto+250ᵒC 1.2 3.4 - 16-40 0.3-1.7 43-65-126 162W91 -91 oto+250ᵒC 11.0 12 - 26-80 0.5-3.0 95-127-190 770W91t -91 oto+250ᵒC 11.0 24 - 26-80 0.5-3.0 95-127-190 780W91tt -91 oto+250ᵒC 11.0 36 - 26-80 0.5-3.0 95-127-190 790W91x -91 oto+250ᵒC 11.0 12 - 18-70 0.8-5.5 95-127-190 785W91tx -91 oto+250ᵒC 11.0 24 - 18-70 0.8-5.5 95-127-190 795W91ttx -91 oto+250ᵒC 11.0 36 - 18-70 0.8-5.5 95-127-190 805W92 -92 oto+250ᵒC 31.0 12 - 26-80 0.5-3.0 95-127-190 785W92t -92 oto+250ᵒC 31.0 24 - 26-80 0.5-3.0 95-127-190 795W92tt -92 oto+250ᵒC 31.0 36 - 26-80 0.5-3.0 95-127-190 805W92x -92 oto+250ᵒC 31.0 12 - 18-70 0.8-5.5 95-127-190 800W92tx -92 oto+250ᵒC 31.0 24 - 18-70 0.8-5.5 95-127-190 810W92ttx -92 oto+250ᵒC 31.0 36 - 18-70 0.8-5.5 95-127-190 820LH46 -45 oto+250ᵒC 2.5 1.8 - 16-30 0.5-1.6 50-59-64 103LH47 -47 oto+250ᵒC 3.7 1.8 - 16-30 0.5-1.6 40-55-127 150LH50 -50 oto+250ᵒC 5.5 6.0 - 16-30 0.7-2.2 40-55-127 182Magnum91 -91 oto+250ᵒC 3.0 6.0 - 30-50 0.8-1.9 71-88-165 442FC600 -20 oto+80ᵒC 0.6 1.2 6-8 20 0.5 35-54-49 48FC600S -10 oto+80ᵒC 0.5 1.2 6-8 22 1.2 35-54-49 52FC1200 -20 oto+80ᵒC 1.3 1.2 8-11 20 0.5 46-61-49 60FC1200S -15 oto+80ᵒC 1.2 1.2 8-11 22 1.2 46-61-49 66FC1600 -20 oto+80ᵒC 1.65 1.2 8-11 20 0.5 46-61-49 65FC1600S -15 oto+80ᵒC 1.55 1.2 8-11 22 1.2 46-61-49 66FC1299T -10 oto+80ᵒC 1.1 1.2 8-11 28 3.5 46-61-49 67FC1600T -15 oto+80ᵒC 1.45 1.2 8-11 28 3.5 46-61-49 67FCW600 -20 oto+80ᵒC 0.6 1.2 6-8 20 0.5 35-54-49 48FCW600S -10 oto+80ᵒC 0.5 1.2 6-8 22 1.2 35-54-49 52FCW2500T -25 oto+80ᵒC 2.5 1.2 8-11 28 3.5 46-61-49 74SC2500a +5 oto+35ᵒC 2.5 - 21-33 33 3.5 49-62-105 123SC2500w +5 oto+35ᵒC 2.5 - 21-33 33 3.5 49-62-105 123SC5000a +5 oto+35ᵒC 5.0 - 43-60 33 3.5 59-67-112 153SC5000w +5 oto+35ᵒC 5.0 - 43-60 33 3.5 59-67-112 153SC10000w +5 oto+35ᵒC 10.0 - 43-60 33 3.5 59-67-112 159SL-8K +50 oto+300ᵒC - 3 8 22-66 0.4-0.7 22-46-47 16SL-14K +50 oto+300ᵒC - 3 14 22-66 0.4-0.7 22-46-61 20FK30-SL -30 oto+200ᵒC 0.46 2 14 22-66 0.4-0.7 32-45-79 48FK31-SL -30 oto+200ᵒC 0.46 2 24 22-66 0.4-0.7 32-45-91 51ME-31A +20 oto+60ᵒC - 2 31 11-16 0.23-0.45 50-20-56 11ME-16G +20 oto+100ᵒC - 2 16 11-16 0.23-0.45 Ø29-48 9ME-18V +20 oto+150ᵒC - 2 18 11-16 0.23-0.45 36-24-54 17

F38-ME -38 oto+80ᵒC 0.92 2 45 11-16 0.23-0.45 46-70-89 72

CF30 -30 oto+150ᵒC 0.32 2 3.5 15 0.35 24-46-40 35CF40 -40 oto+150ᵒC 0.47 2 5.5 15 0.35 28-46-46 41CF31 -30 oto+200ᵒC 0.32 2 3.5 22-26 0.4-0.7 24-46-40 36CF41 -40 oto+200ᵒC 0.47 2 5.5 22-26 0.4-0.7 28-46-46 42

Type

Presto Highly

Dynamic Temp

Control Systems

Recirculating Coolers

Calibration Baths

Cryo-Compact

Circulators

Model Temp Range Application Examples

Fill Volume (L)

Flow Rate (L/min)

Size (cm)W-L-H

Weight(kg)

Pump Pressure (bar)

Jacketed reactors, reactor systems & autoclaves (polymerisation,

poly-condensation, etc), combinatorial chemistry, reaction blocks, organic synthesis, reaction

calorimeters, distillation, pilot plants, semiconductor industry

Reactor systems, mini plants, pilot plants, Kilo labs, process

technology, vacuum chambers

Rotary evaporators, electron microscopes, lasers, mills &

kneaders, pilot plants, plastics industry, drying of gases, general

industrial applications

Semi-conductor industry, packaging & plastics industries,

metering & adhesive technology, jacketed reaction vessels, Kilo

labs, pilot plants

Calibration for determination of conformity to national and

international standards such as temperature sensors, measuring

devices or thermometersMeasurements with capillary

viscometers or use of densimeters & other related products (enabling

conformity to ASTM D445)Forcing tests, ‘best before’ date by

simulating beer aging process

External temperature control applications, distillation apparatus & mini-plant installations, limited

space (in fume hoods)

Heating Capacity

(kW)

Cooling Capacity at 20ᵒC

(kW)

Page 6: Julabo temp control summary nz

Toll Free: 0800 651 700 6 www.jms.co.nz

Scientific

JohnMorris John Morris Scientific

Service plus Solutions

Type

Recirculating Coolers

Immersion Coolers

Model Temp Range Application Examples

Fill Volume (L)

Cooling capacity at 20ᵒC (kW)

Flow Rate (L/min)

Size (cm)W-L-H

Weight(kg)

Pump Pressure (bar)

Cooling of Peltier elements, particularly for automated analysis units & CCD

cameras, polarimeters, refractometers, electrophoresis chambers, condensers

for glass apparatus

Rotary evaporators, bio-reactors/fermenters, Soxhlet apparatus,

distillation systems, vacuum systems, gas chromatographs, spectrometers,

semiconductor applications, metering & adhesive technology, diffusion

pumps, mass spectrometers, electron microscopes

Electron microscopes, lasers, mills & kneaders, pilot plants, plastics industry,

drying of gases, general industrial applications

Cooling of liquids, dry-ice substitute, counter-cooling for heating circulators,

saving of tap water

Heating circulators for sub-ambient temp, integration into loop circuits

Storing & cooling of chemicals & hazardous substances

For Chemicals

Recirculating Cooler (F250)

Recirculating Cooler (FL300)

Recirculating Cooler (FL1203)

Recirculating Cooler (FL601)

Recirculating Cooler (FL1703)

Images of Cooling Only Equipment

German quality with a full 2 year warranty

F250 -10 oto+40ᵒC 0.25 1.7-2.6 15 0.35 24-40-52 27F500 0 oto+40ᵒC 0.5 5-7.5 24 0.5 37.5-44-59 34F1000 0 oto+40ᵒC 1.0 7-9.5 23 1.0 37.5-49-64 45AWC100 +20 oto+40ᵒC 0.55 0.9 2.9 0.2 20-34-30 11FL300 -20 oto+40ᵒC 0.3 3-4.5 15 0.35 25-50-60 39FL601 -20 oto+40ᵒC 0.6 5.5-8 23 1.0 32-50-60 48FL1201 -20 oto+40ᵒC 1.2 12-17 23 1.0 50-76-64 76FL1203 -20 oto+40ᵒC 1.2 12-17 40 0.5-3.0 50-76-64 91FL1701 -20 oto+40ᵒC 1.7 12-17 23 1.0 50-76-64 85FL1703 -20 oto+40ᵒC 1.7 12-17 40 0.5-3.0 50-76-64 91FLW1701 -20 oto+40ᵒC 1.7 12-17 23 1.0 50-76-64 82FLW1703 -20 oto+40ᵒC 1.7 12-17 40 0.5-3.0 50-76-64 88FL2503 -20 oto+40ᵒC 2.5 24-30 40 0.5-3.0 60-76-115 146FL2506 -15 oto+40ᵒC 2.5 24-30 60 0.5-6.0 60-76-115 158FL4003 -20 oto+40ᵒC 4.0 24-30 40 0.5-3.0 60-76-115 148FL4006 -20 oto+40ᵒC 4.0 24-30 60 0.5-6.0 60-76-115 157FLW2503 -20 oto+40ᵒC 2.7 24-30 40 0.5-3.0 60-76-115 143FLW2506 -15 oto+40ᵒC 2.5 24-30 60 0.5-6.0 60-76-115 160FLW4003 -20 oto+40ᵒC 4.3 24-30 40 0.5-3.0 60-76-115 143FLW4006 -20 oto+40ᵒC 4.0 24-30 60 0.5-6.0 60-76-115 160FL7006 -20 oto+40ᵒC 7.0 39-47 60 0.5-6.0 78-85-148 252FL11006 -20 oto+40ᵒC 11.0 39-47 60 0.5-6.0 78-85-148 248FL20006 -25 oto+40ᵒC 20.0 15-37 80 0.8-6.0 95-115-161 360FLW7006 -20 oto+40ᵒC 7.4 39-47 60 0.5-6.0 78-85-148 220FLW11006 -20 oto+40ᵒC 11.5 39-47 60 0.5-6.0 78-85-148 250FLW20006 -25 oto+40ᵒC 20.0 15-37 80 0.8-6.0 95-115-161 360FT200 -20 oto+30ᵒC 0.25 - - - 18-27-39 18FT400 -40 oto+30ᵒC 0.45 - - - 20-30-43 24FT900 -90 oto+30ᵒC 0.3 - - - 38-55-60 50FT402 -40 oto+30ᵒC 0.45 - - - 20-30-43 24FT902 -90 oto+30ᵒC 0.3 - - - 38-55-60 50

FD200 +10 oto+30ᵒC 0.22 - - - 18-27-39 16

KRC50 -2 oto+12ᵒC - 50 - - 53-63-54 23KRC180 -2 oto+12ᵒC - 180 - - 60-64-86 35

Cooling Only Equipment

Page 7: Julabo temp control summary nz

Toll Free: 0800 651 700 7 www.jms.co.nz

Evaporation & Concentration

Commonly used in laboratories for synthetic chemistry, organic chemistry, scale-ups or in R&D labs for pharmaceuticals, chemicals, cosmetics and nutritional chemistry.

Evaporation and concentration without consumption of water, elevated efficiency even at cooling temperatures as low as -10°C.

John Morris Scientific also supplies an extensive range of Vacuubrand vacuum pumps.

Wireless Operation

WirelessTEMP products allow wireless monitoring and operation of up to eight Julabo temperature control instruments via PC or remote control:

• Comfortable operation of instruments directly from your workstation• Reduces time and resources for monitoring the instruments• Increased freedom in choosing a location for the instrument• No need for communication cables• Easy to handle remote control

Accessories

John Morris Scientific also has an extensive range of Julabo accessories & spare parts.

Repairs & Maintenance

Our Instrument Services Division provides a choice of Service Agreements to suit your needs & performs routine maintenance & repairs on all Julabo temperature control equipment to ensure it is operating to its optimum capacity.

Remote control to control & monitor up to 8 Julabo instruments

PC & Wireless USB Stick to control & monitor up to 8 Julabo instruments

To ensure you select the right temperaure control equipment for your needs or for servicing your equipment, simply contact John Morris Scientific for professional assistance.

Page 8: Julabo temp control summary nz

For Over 50 Years

Scientific

JohnMorris John Morris Scientific

Service plus Solutions

At John Morris Scientific we offer more than just the product - we provide the full package -

sales and servicing of instrumentation plus design tailored solutions to meet your needs.

Address 78 Wellesley Street Auckland NZ 1010Toll Free 0800 651 700Enquiries +64 (0) 9 366 3999 Email [email protected] www.jms.co.nz