J Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior...

11
j 9001 R osehillR oad,Lenexa,K S 66215 U SA Tel: (+1)913 888 7172 Fax: (+1)913 888 7372 W ebsite:http://w w w.akrofire.com A kro Firegu ard Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior Repair Compounds

description

j Low Smoke Fire Resistant Floor Coverings AkroBak ® Nylon Carpet FAR RequirementsOEM Requirements (Summary ref, ABD0031 & BSS 7239/8) Vertical Burn: 12seconds Smoke Density: N/RSmoke Density: 150 (300) Dm after 4 min Toxicity: N/R Toxicity: CO: 3500 ppm HCN: 150 ppm HF: 100 (200) ppm HCL: 150 (500) ppm SO 2 : 100 (200) ppm NO X : 100 ppm Comparative Data: FST Requirements FAA : OEM

Transcript of J Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior...

Page 1: J Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior Repair Compounds.

j

9001 Rosehill Road, Lenexa, KS 66215 USA Tel: (+1) 913 888 7172 Fax: (+1) 913 888 7372

Website: http://www.akrofire.com

Akro Fireguard

Developments in:

- Low Smoke Fire Resistant Floor Coverings

- Low Smoke Fire Resistant Interior Repair Compounds

Page 2: J Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior Repair Compounds.

j

Akro Fireguard

Low Smoke Fire Resistant Floor Coverings:Low Smoke Fire Resistant Floor Coverings:

  •Wool – Naturally flame retardant and used to meet stricter OEM FST requirements.

Used extensively outside USA

•Conventional Nylon – Brominated Flame retardants – meets FAA standards.Used extensively in USA

Summary:•Wool – Good FST Performance – Poor Operational Performance.

Meets OEM FST requirements

•Nylon – Excellent Operational Performance – High smoke and toxic gases.Up to 5x ware improvement

 

AkroBak Nylon – The best features of wool and Nylon

AkroBakAkroBak®® Nylon Carpet Nylon Carpet

Background

Page 3: J Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior Repair Compounds.

j

Akro Fireguard

Low Smoke Fire Resistant Floor CoveringsLow Smoke Fire Resistant Floor Coverings AkroBakAkroBak®® Nylon Carpet Nylon Carpet

FAR 25.853 Requirements OEM Requirements(Summary ref, ABD0031 & BSS 7239/8)

Vertical Burn: 12seconds Vertical Burn: 12seconds

Smoke Density: N/R Smoke Density: 150 (300) Dm after 4 min

Toxicity: N/R

Toxicity: CO: 3500 ppm HCN: 150 ppm HF: 100 (200) ppm HCL: 150 (500) ppm SO2: 100 (200) ppm NOX: 100 ppm

Comparative Data: FST Requirements FAA : OEM

Page 4: J Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior Repair Compounds.

j

Akro Fireguard

Low Smoke Fire Resistant Floor CoveringsLow Smoke Fire Resistant Floor Coverings AkroBakAkroBak®® Nylon Carpet Nylon Carpet

Specimen Flame Application

Flame TimeSec.

BurnLength

Inch

Flaming Drippings

FlameTimeSec.

BurnLengthInch.

FlamingDrippings

123

121212

100

2.72.72.4

000

011

2.62.72.6

000

Average 0.3 2.6 0.0 0.7 2.6 0.0

Length Direction Width Direction

Vertical Burn : Summary of Results

Page 5: J Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior Repair Compounds.

j

Akro Fireguard

Low Smoke Fire Resistant Floor CoveringsLow Smoke Fire Resistant Floor Coverings

Comparative Data: Smoke Density

Nylon Carpet Smoke TestsASTM E662, 4-min. flaming mode

0

100

200

300

400

500

0 1 2 3 4

Time (min)

Smok

e D

enis

ty

NYLON

AKROBAK NYLON

A smoke density of 470 is the instrumental measurement limit

AkroBakAkroBak®® Nylon Carpet Nylon Carpet

LIMITLIMIT

Page 6: J Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior Repair Compounds.

j

Akro Fireguard

Low Smoke Fire Resistant Floor CoveringsLow Smoke Fire Resistant Floor Coverings

Comparative Data: Toxicity

AkroBakAkroBak®® Nylon Carpet Nylon Carpet

0500

100015002000250030003500

ppm

CO HCN HF HCL SO2 NOx

Compound

Toxicity - ASTM E 662 (Flaming Mode)

Requirement

AkroBak

100 15 300025Actual Akrobak results

3500

150 100 150 100 100

Maximum Allowable

Page 7: J Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior Repair Compounds.

j

Akro Fireguard

Low Smoke Fire Resistant Floor CoveringsLow Smoke Fire Resistant Floor Coverings

‘In service Durability’

Static propensity – BSS 7311: Leather/Rubber 0.5kV, Composition : 0.6kV - Requirement < 2.5kV

Dimensional Stability (4’x10’ Sample) – BSS 7310: Length: -0.5%, Width 0% - Requirement < 5%

Vetterman Drum Test (22,000 revolutions): Rating 3.3 (Moderate Change) - Requirement N/A

Hexapod Tumbler – ASTM D-5252, 12,000 cycles: Rating 3 (Moderate Change) - Requirement N/A

Ultimate performance indicator - in service experience:

3x improvement in longevity over traditional FST compliant carpeting

AkroBakAkroBak®® Nylon Carpet Nylon Carpet

Testing performed, summary of results

Page 8: J Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior Repair Compounds.

j

Akro Fireguard

Low Smoke Fire Resistant Floor CoveringsLow Smoke Fire Resistant Floor Coverings

CONCLUSION

AkroBakAkroBak®® Nylon Carpet Nylon Carpet

AkroBak Nylon Carpet

•Superior resistance to soiling and staining.

•Superior durability and maintainability.

•Low weight.

•Total cost of ownership

•Meets the highest FST standards

•Does not contain Bromine compounds and is therefore compliant with current and Impending legislation.

Visit us at http://www.akrofire.com

Page 9: J Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior Repair Compounds.

j

Akro Fireguard

Low Smoke Fire Resistant Interior Repair CompoundsLow Smoke Fire Resistant Interior Repair Compounds AF444 SpeedFillAF444 SpeedFill

AF444 SpeedFill was developed to provide a universal filling and repair compound that would meet:

•OSU Heat Release

•Vertical Burn

•Smoke Density

Cure characteristics such that the material can be used effectively during ‘change around’ operations.

AF444 SpeedFill

Page 10: J Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior Repair Compounds.

j

Akro Fireguard

Low Smoke Fire Resistant Interior Repair CompoundsLow Smoke Fire Resistant Interior Repair Compounds AF444 SpeedFillAF444 SpeedFill

•FAR 25.853 OSU Heat Release Average: 12 Peak: 45

ASTM E662 Smoke Density (flaming mode) 127

Vertical Burn 12 second & 60 second

Compressive Strength 6360 psi / 44MPa

Density 1.16g/cm3 / 72lb/ft3

Basic Properties

Page 11: J Developments in: - Low Smoke Fire Resistant Floor Coverings - Low Smoke Fire Resistant Interior Repair Compounds.

j

Akro Fireguard

Low Smoke Fire Resistant Interior Repair CompoundsLow Smoke Fire Resistant Interior Repair Compounds AF444 SpeedFillAF444 SpeedFill

•Mixing: 2 pack system, Part A & B, 2% Part B

•Application: Trowel / Spatula

•Shaping After 10 to 20 minutes

•Cure 30 to 40 minutes

Applications

•Sandwich Panel core repair: (Airbus approved for cargo liner repairs)

•Interior panel repair

Handling