1-1 FibeAir ® IP-10 IDU Installation Guide Part ID: BM-0237-0 Doc ID: DOC-00018797 Rev b.01 January 2009

Transcript of IP-10 IDU Installation (Rev b.01)

Page 1: IP-10 IDU Installation (Rev b.01)

1-1

FibeAir® IP-10

IDU

Installation

Guide

Part ID: BM-0237-0

Doc ID: DOC-00018797 Rev b.01

January 2009

Page 2: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-2

Notice

This document contains information that is proprietary to Ceragon Networks Ltd.

No part of this publication may be reproduced, modified, or distributed without prior written authorization of Ceragon Networks Ltd.

This document is provided as is, without warranty of any kind.

Registered TradeMarks

Ceragon Networks® is a registered trademark of Ceragon Networks Ltd.

FibeAir® is a registered trademark of Ceragon Networks Ltd.

CeraView® is a registered trademark of Ceragon Networks Ltd.

Other names mentioned in this publication are owned by their respective holders.

TradeMarks

CeraMapTM, PolyView

TM, EncryptAir

TM, ConfigAir

TM, CeraMon

TM, EtherAir

TM, and MicroWave Fiber

TM, are

trademarks of Ceragon Networks Ltd.

Other names mentioned in this publication are owned by their respective holders.

Statement of Conditions

The information contained in this document is subject to change without notice.

Ceragon Networks Ltd. shall not be liable for errors contained herein or for incidental or consequential damage in connection with the furnishing, performance, or use of this document or equipment supplied with it.

Information to User

Any changes or modifications of equipment not expressly approved by the manufacturer could void the user’s authority to operate the equipment and the warranty for such equipment.

Copyright © 2008 by Ceragon Networks Ltd. All rights reserved.

CorporaCorporaCorporaCorporate Headquarters:te Headquarters:te Headquarters:te Headquarters:

Ceragon Networks Ltd. 24 Raoul Wallenberg St. Tel Aviv 69719, Israel Tel: 972-3-645-5733 Fax: 972-3-645-5499 Email: [email protected]

www.ceragon.com

European Headquarters:European Headquarters:European Headquarters:European Headquarters:

Ceragon Networks (UK) Ltd. 4 Oak Tree Park, Burnt Meadow Road North Moons Moat, Redditch, Worcestershire B98 9NZ, UK Tel: 44-(0)-1527-591900 Fax: 44-(0)-1527-591903 Email: [email protected]

North American Headquarters:North American Headquarters:North American Headquarters:North American Headquarters:

Ceragon Networks Inc. 10 Forest Avenue, Paramus, NJ 07652, USA Tel: 1-201-845-6955 Toll Free: 1-877-FIBEAIR Fax: 1-201-845-5665 Email: [email protected]

APAC HeadquartersAPAC HeadquartersAPAC HeadquartersAPAC Headquarters

Ceragon Networks (HK) Ltd. Singapore RO Level 34 Centennial Tower 3 Temasek Avenue Singapore 039190 Tel - + 65 6549 7886 Fax: +65 6549 7011

Page 3: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-3

Contents

Chapter 1: Installation ................................................................................... 1-4

General ................................................................................................................1-4

Site Requirements ..............................................................................................1-4

Pre-Installation....................................................................................................1-4

Unpacking Equipment at the Site ......................................................................1-5

Installation Requirements..................................................................................1-5

FibeAir IP-10 Description ...................................................................................1-7

Installing the IDU in a Rack................................................................................1-8

Grounding the IDU............................................................................................1-10

Connecting the IDU ..........................................................................................1-12

TDM Interface Add-on Slots…………………………………………………………1-12

IP-10 Nodal Design…………………………………………...……………………….1-14

Configuring the IDU..........................................................................................1-16

Appendix A: Line Interfaces ....................................................................... 1-17

Appendix B: Connector Pin-Outs............................................................... 1-21

Appendix C: Protection Information .......................................................... 1-27

Appendix D: Accesories.............................................................................. 1-30

Appendix E: Fan Tray Replacment............................................................. 1-33

Page 4: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-4

Chapter 1: Installation

General

This chapter provides instructions for the installation of the FibeAir IP-10 IDU at the customer site.

Site Requirements

Must be located indoors.

The environment temperature must be between -5 C and +55 C.

Easily accessible, but only by authorized personnel.

Available power source of -48 VDC, and the site must comply with National Electric Code (NEC)

standards.

Available management connection (Ethernet or dial-up).

No more than 300 m from RFU location.

In addition, since the IDU will be connected to the RFU, when considering a site, it is important to check for

current and future obstacles on the roof or tower. Possible future obstacles may include trees, new buildings,

window cleaners on the roof, snow that may accumulate in front of the antenna, etc. The site should be

accessible to certified personnel only.

Note about Heat Dissipation: The IP-10 IDU overall heat dissipation is 25W max (~85 BTU/h).

Note about Antenna Location: As with any type of construction, a local permit may be required before

installing an antenna. It is the owner’s responsibility to obtain any and all permits.

Pre-Installation

Packing

The equipment is packed at the factory, and sealed moisture-absorbing bags are inserted.

Transportation

The equipment is prepared for public transportation. The cargo must be kept dry during transportation,

in accordance with ETS 300 019-1-2, Class 2.3.

It is recommended to transport the equipment to the installation site in its original packing case.

If intermediate storage is required, the packed equipment must be stored in dry and cool conditions and

out of direct sunlight, in accordance with ETS 300 019-1-1, Class 1.2.

Page 5: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-5

Inspection

Check the packing lists, and ensure that the correct part numbers and quantities of components arrived.

Unpacking Equipment at the Site

A single FibeAir system (1+0) is shipped in 5 crates. Upon delivery, make sure that the following items are

included:

Two indoor units and accessories

Two outdoor units

For 13-38 GHz systems, verify that there is a high RFU and low RFU.

One CD with a management user guide.

Unpack the contents and check for damaged or missing parts. If any part is damaged or missing, contact your

local distributor.

Installation Requirements

Required Tools

The following tools are required to install the IDU:

Philips screwdriver (for mounting the IDU to the rack and grounding screw)

Flathead small screwdriver (for PSU connector)

Sharp cutting knife (for wire stripping)

Crimping tool for ground cable lug crimping (optional: if alternative grounding cable is used).

Cables

In addition to the tools mentioned above, the interface connectors and their pin-outs, can be found in the

following sections in this guide:

Appendix A: Line Interfaces

Appendix B: Connector Pin-Outs

Page 6: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-6

Requirements for North America

Restricted Access Area: DC powered equipment should only be installed in a Restricted Access Area.

Installation Codes: The equipment must be installed according to country national electrical codes. For

North America, equipment must be installed in accordance to the US National Electrical Code, Articles 110-

16, 110-17 and 110-18, and the Canadian Electrical Code, Section 12.

Overcurrent Protection: A readily accessible Listed branch circuit overcurrent protective device, rated 15 A,

must be incorporated in the building wiring.

CAUTION: This equipment is designed to permit connection between the earthed conductor of the DC

supply circuit and the earthing conductor at the equipment.

Grounded Supply System: The equipment shall be connected to a properly grounded supply system. All

equipment in the immediate vicinity shall be grounded the same way, and shall not be grounded elsewhere.

Local Supply System: The DC supply system is to be local, i.e. within the same premises as the equipment.

Disconnect Device: A disconnect device is not allowed in the grounded circuit between the DC supply source

and the frame/grounded circuit connection.

Page 7: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-7

FibeAir IP-10 Description

FibeAir IP-10 is Ceragon's comprehensive high capacity migration-to-IP network solution. The innovative IP-

10 was designed as a native Ethernet microwave radio platform that can integrate smoothly in any network,

while providing a broad range of software-configurable licensed channel schemes.

IP-10 follows in the tradition of Ceragon's Native2, which allows your network to benfit from both native

TDM and native Ethernet using the same radio. Flexible bandwidth sharing between the TDM and Ethernet

traffic ensures optimal throughput for all your media transfer needs.

IP-10 features a flexible design capable of addressing all network migration scenarios. With its Native2

capability for optimal traffic delivery, and modular architecture for all sites (Tail, Chain, Agg3, Agg2), this

state-of-the-art radio platform offers the best approach to IP migration for advanced networks.

With the widest capacity range (10-500 Mbps) for all capacity needs, advanced Adaptive Code Modulation for

the best spectrum utilization, and a scalable system that ensures future-proof network expansion, IP-10 is the

ideal solution for risk-free migration.

Some of the important points that place IP-10 at the top of the wireless IP market include:

Supports all licensed bands, from 6 to 38 GHz

Supports channel bandwidths of from 7 MHz to 56 MHz

Supports throughputs of from 10 to 500 Mbps per radio carrier (QPSK to 256 QAM)

Incorporates advanced integrated Ethernet switching capabilities

In addition, using unique Adaptive Code & Modulation (ACM), your network benefits from non-stop,

dependable capacity deliverance.

FibeAir IP-10 IDU

Page 8: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-8

Installing the IDU in a 19"/ETSI Rack

Warning! The intra-building port(s) of the equipment or subassembly is suitable for

connection to intra-building or exposed wiring or cabling only. The intra-building port(s) of the eqiupment or subassembly MUST NOT be metallically connected to interfaces that connect to the OSP or its wiring. These interfaces are designed for use as intra-building interfaces only and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.

The FibeAir IP-10 IDU is installed in a standard 19" ETSI rack as shown in the following illustration.

As shown in the illustration, four screws, supplied with the installation kit, are used to secure the IDU to the

rack.

Page 9: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-9

IDU Dimensions

The following illustration shows the dimensions (in millimeters) of the FibeAir IP-10 IDU.

Page 10: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-10

Grounding the IDU

The following illustration shows how the IDU is grounded to the rack.

A grounding wire is connected below the IDU-RFU interface using a single screw with two washers.

IDU Grounding Notes

• The IDU is suitable for installation in a Common Bonding Network (CBN).

• Only copper wire should be used.

• The wire must be at least 6 AWG.

• Connector and connection surfaces must be plated. Bare conductors must be be coated with antioxidant

before crimp connections are made to the screws.

• FibeAir provides a ground for each IDU, via a one-hole mounted lug onto a single-point stud. The stud

must be installed using a UL-listed ring tongue terminal, and two star washers for anti-rotation.

Single Point Stud

Grounding Wire

Page 11: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-11

• For antenna ports, lightning protection is used that does not permit transients of a greater magnitude than

the following:

Open Circuit: 1.2-50us 600V

Short Circuit: 8-20us 300A

• The ampacity of the conductor connecting the IDU frame to the DC return conductor is equal to, or

greater than, the ampacity of the associated DC return conductor.

Power Supply Notes

When selecting a power source, the following must be considered:

• DC power can be from -40.5 VDC to -60 VDC.

• Recommended: Availability of a UPS (Uninterrupted Power Source), battery backup, and emergency

power generator.

• Whether or not the power source provides constant power (i.e., power is secured on weekends or is shut

off frequently and consistently).

• The power supply must have grounding points on the AC and DC sides.

Caution!

The user power supply GND must be connected to the positive pole in the IDU power supply. Any other

connection may cause damage to the system!

Power supply grounding should be in accordance with the following illustration:

Page 12: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-12

Connecting the IDU

This section describes how the IDU interfaces are connected for a 1+0 system. The interfaces include line,

system (IDU-RFU), and management ports.

For interface specifications, see Appendix A - Line Interfaces and Cables.

For connector pin-outs, see Appendix B - Connector Pin-Outs.

For a list of accessories, see Appendix D - Accessories.

Note: For a 1+1 system, a protection panel is used, as described in Appendix C - Protection Information.

Interface Descriptions

The following photo shows the different IDU ports and their functions.

IDU Front Panel

The IDU front panel includes the following auxiliary interfaces:

Terminal console

Ethernet out-of-band management

Ethernet wayside

External

Alarms

(DB9)

16 x E1/T1s

(optional)

Engineering

order-wire

(optional)

User

Channel

(optional)

(RJ45)

2 x GE ”combo”

ports

Electrical (RJ45)

or Optical (SFP)

5 x FE

Electrical

(RJ45)

RFU

interface

(N-Type)Power

-48V DCProtection

Interface

(RJ45)

TDM interfaces

add-on slot

Fans

drawer

GND

Page 13: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-13

Optional:

Engineering Order Wire (EOW)

User channel (V11, RS232)

External alarms

Note: The Fast Ethernet interface channels can be logically configured for either Fast Ethernet traffic, or

protection, wayside, or management traffic.

TDM Interface Add-on Slots:

FibeAir IP-10 Release 2 supports TDM interface expansion cards ("T-cards") for:

16 x E1s/T1s (32 total per unit)

STM-1/OC-3 (terminal mux for up to 63 E1s or 84 T1s)

Supported TDM Expansion Card Types

The T-cards are field-upgradable, and add a new dimension to the FibeAir IP-10 migration flexibility.

16 x E1/T1 T-Card

Page 14: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-14

IP-10 Nodal Design

IP-10 design for the nodal solution is based on a "blade" approach. Viewing the unit from the rear, each IDU

can be considered a "blade" within a nodal enclosure.

A "blade" can operate as a stand-alone unit at a tail site.

The "rack chassis" is also modular, for optimum economical future upgrade, network design flexibility, and efficient installation, maintenance, and expansion.

The solution is modular and forms a single unified nodal device, with a common Ethernet Switch, common E1 Cross-Connect, single IP address, and a single element to manage.

Page 15: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-15

Nodal Design Types

The following types of nodal enclosures are supported:

Modular Rack Chassis

The nodal enclosure is a scalable unit. Each enclosure can be added to another enclosure for modular rack

installation.

Page 16: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-16

IDU-ODU/RFU Coax Cable

The Coax Cable that connects between the IDU and the ODU/RFU should be terminated with N-type male

connectors.

Important! Make sure that the inner pin of the connector does not exceed the edge of the connector.

The cable should have a maximum attenuation of 30 dB at 350 MHz.

Configuring the IDU

After the system is installed and tested, and antenna alignment is performed, the next step is IDU setup and

configuration.

Setup procedures are performed using the FibeAir IP-10 CLI (Command Line Interface) or Web Based

Management.

For an explanation of the CLI, see the FibeAir IP-10 CLI Guide.

For an explanation of the Web Based Management, see the FibeAir IP-10 Web Based Management Guide.

Page 17: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-17

Appendix A: Line Interfaces

This section provides a description of the FibeAir main channel, wayside channel, and order wire channel

interfaces.

The interfaces are located on the FibeAir IDU front panel.

The following interface terms should be noted:

For connectors or signals labeled TX, the signals are sent from FibeAir.

For connectors or signals labeled RX, the signals are sent to FibeAir.

Main Channel Interfaces

Main channel interfaces include the following:

Gigabit Ethernet (Optical)

1000Base-SX (Multi Mode)

Wavelength: 850 nm

Receptacle: MSA compliant, SFP (Small Form Factor Pluggable Ports)

Connector: LC

Max Segment Length: 220 m (1351 ft), 500 m (1650 ft)

Cable Type: For Max Segment = 220 m: 62.5 µm MMF

For Max Segment = 500 m: 50 µm MMF

1000Base-LX (Single Mode)

Wavelength: 1350 nm

Receptacle: MSA compliant, SFP (Small Form Factor Pluggable Ports)

Connector: LC

Max Segment Length: 550 m (1805 ft), 5000 m (16404 ft)

Cable Type: For Max Segment = 550 m: 62.5 µm MMF, 50 µm MMF

For Max Segment = 5000 m: 10 µm SMF

Page 18: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-18

Gigabit Ethernet / Fast Ethernet (Electrical)

100/1000BaseT (Twisted Pair Cable)

Connector: RJ-45

Max Segment Length: Up to 100 m (328 ft) per IEEE802.3

Cable Type: Compatible with shielded and unshielded twisted pair category 5 cables.

Optional 16xE1/T1

Connector MDR 69-pin

Used with: Twisted pair

Interface Type E1/T1

Number of ports 16 per unit (optional)

Timing mode: Retimed

Framing Unframed (full transparency)

Coding E1: HDB3

T1: AMI/B8ZS

Range: 5 m

Line Impedance 120 Ω/100 Ω balanced. Optional module for 75 Ω unbalanced

Compatible Standards ITU-T G.703, G.736, G.775, G.823, G.824, G.828, ITU-T I.432, ETSI ETS 300 147, ETS 300 417, ANSI T1.105, T1.102-1993, T1.231, Bellcore GR-253-core, TR-NWT-000499

Wayside Channel Interface

The wayside channel is used as an auxiliary audio or data channel.

10/100BaseT (Ethernet)

Connector: Shielded RJ-45

Used with: UTP Cat 5

Protocols supported: Ethernet (10/100BaseT), half or full duplex

Timing mode: Retimed

Range: 100 m

Impedance: 100 Ω

Page 19: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-19

Protection Channel Interface

Protection

Connector: Shielded RJ-45

Used with: UTP Cat 5

Protocols supported: Ethernet (10/100BaseT), half or full duplex

Timing mode: Retimed

Range: 100 m

Impedance: 100 Ω

Management Channel Interface

Out-of-Band Management

Connector: Shielded RJ-45

Used with: UTP Cat 5

Protocols supported: Ethernet (10/100BaseT), half or full duplex

Timing mode: Retimed

Range: 100 m

Impedance: 100 Ω

Order Wire Channel Interface

The Order Wire is used for audio transmission for testing or maintenance purposes.

The specifications for this channel are as follows:

Termination Type: Headset stereo plug, 2.5 mm

Frequency band (KHz) 0.3-3.4

Input impedance (ohms) ~2000

Output impedance (ohms) 32

Page 20: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-20

User Channel Interface

The user channel is a CVSD audio channel that delivers 64 Kbps, via an RJ-45 connector.

The interface can be used for one of the following:

Asynchronous RS-232

Asynchronous V-11

Co and Contra Directional

Page 21: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-21

Appendix B: Connector Pin-Outs

General

This appendix provides pin-outs for FibeAir IDU connectors, including the following:

External Alarms Connector

Protection/Wayside/Management Connector

Power Connector

16 x E1/T1 Connector

Ethernet 10/100/1000 Connector

Ethernet 10/100 Connector

User Channel Connector

Page 22: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-22

External Alarms Connector Pin-Out The External Alarms connector is a D-type 9-pin connector.

Pin Signal I/O Description

1 EXT_IN5 Input External input alarm #5

2 EXT_IN4 Input External input alarm #4

3 EXT_IN3 Input External input alarm #3

4 EXT_IN2 Input External input alarm #2

5 EXT_IN1 Input External input alarm #1

6 GND GND GND

7 RELAY_1_NO Output Relay #1, normally open pin

8 RELAY_1_C Output Relay #1, common pin

9 RELAY_1_NC Output Relay #1, normally closed pin

Protection/Wayside/Management Connector Pin-Out The Protection/Wayside/Management connector is an RJ-45, 8-pin, female type connector.

RJ-45 Male Connector

Pin Signal

1

2 Twisted Pair, Out - Tx

3

6 Twisted Pair, In - Rx

4

5 Not Connected

7

8 Not Connected

Page 23: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-23

Power Connector Pin-Out The power connector pin-out is as follows:

Left Pin (#1) Right Pin (#2)

-48V (return current) 0V

Note that right/left refers to viewing the panel from the front.

16 x E1/T1 Connector

The 16 x E1/T1 connector is a SCSI 68-pin connector.

Pin # Signal Label on the Twisted Pair

Type

1 OUT - TIP1

35 OUT - RING1 Ch1 Tx TWISTED PAIR

2 OUT - TIP2

36 OUT - RING2 Ch2 Tx TWISTED PAIR

3 OUT - TIP3

37 OUT - RING3 Ch3 Tx TWISTED PAIR

4 OUT - TIP4

38 OUT - RING4 Ch4 Tx TWISTED PAIR

5 OUT - TIP5

39 OUT - RING5 Ch5 Tx TWISTED PAIR

6 OUT - TIP6

40 OUT - RING6 Ch6 Tx TWISTED PAIR

7 OUT - TIP7

41 OUT - RING7 Ch7 Tx TWISTED PAIR

8 OUT - TIP8

42 OUT - RING8 Ch8 Tx TWISTED PAIR

9 OUT - TIP9

43 OUT - RING9 Ch9 Tx TWISTED PAIR

10 OUT - TIP10

44 OUT - RING10 Ch10 Tx TWISTED PAIR

11 OUT - TIP11 Ch11 Tx TWISTED PAIR

Page 24: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-24

45 OUT - RING11

12 OUT - TIP12

46 OUT - RING12 Ch12 Tx TWISTED PAIR

Pin # Signal Label on the Twisted Pair

Type

13 OUT - TIP13

47 OUT - RING13 Ch13 Tx TWISTED PAIR

14 OUT - TIP14

48 OUT - RING14 Ch14 Tx TWISTED PAIR

15 OUT - TIP15

49 OUT - RING15 Ch15 Tx TWISTED PAIR

16 OUT - TIP16

50 OUT - RING16 Ch16 Tx TWISTED PAIR

19 IN - TIP1

53 IN - RING1 Ch1 Rx TWISTED PAIR

20 IN - TIP2

54 IN - RING2 Ch2 Rx TWISTED PAIR

21 IN - TIP3

55 IN - RING3 Ch3 Rx TWISTED PAIR

22 IN - TIP4

56 IN - RING4 Ch4 Rx TWISTED PAIR

23 IN - TIP5

57 IN - RING5 Ch5 Rx TWISTED PAIR

24 IN - TIP6

58 IN - RING6 Ch6 Rx TWISTED PAIR

25 IN - TIP7

59 IN - RING7 Ch7 Rx TWISTED PAIR

26 IN - TIP8

60 IN - RING8 Ch8 Rx TWISTED PAIR

27 IN - TIP9

61 IN - RING9 Ch9 Rx TWISTED PAIR

28 IN - TIP10

62 IN - RING10 Ch10 Rx TWISTED PAIR

29 IN - TIP11

63 IN - RING11 Ch11 Rx TWISTED PAIR

30 IN - TIP12 Ch12 Rx TWISTED PAIR

Page 25: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-25

64 IN - RING12

31 IN - TIP13

65 IN - RING13 Ch13 Rx TWISTED PAIR

32 IN - TIP14

66 IN - RING14 Ch14 Rx TWISTED PAIR

Pin # Signal Label on the Twisted Pair

Type

33 IN - TIP15

67 IN - RING15 Ch15 Rx TWISTED PAIR

34 IN - TIP16

68 IN - RING16 Ch16 Rx TWISTED PAIR

17 SHELL - SHIELD

18 SHELL - SHIELD

51 SHELL - SHIELD

52 SHELL - SHIELD

Ethernet 10/100/1000 Connector Pin-Out

The Ethernet 10/100/1000 connector is an RJ-45, 8-pin, female type connector.

RJ-45 Female

Connector Pin

Signal

1

2 Twisted Pair (Tx & Rx)

3

6 Twisted Pair (Tx & Rx)

4

5 Twisted Pair (Tx & Rx)

7

8 Twisted Pair (Tx & Rx)

Page 26: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-26

Ethernet 10/100 Connector Pin-Out

The Ethernet 10/100 connector is an RJ-45, 8-pin, female type connector.

RJ-45 Female

Connector Pin

Signal

1

2 Twisted Pair, Out - Tx

3

6 Twisted Pair, In - Rx

4

5 Not Connected

7

8 Not Connected

User Channel Connector Pin-Out

The user channel connector is an RJ-45 connector.

Pin Asynchronous

RS-232 Asynchronous

V11 I/O

1 NC UC_TXD_P Out

2 NC UC_TXD_N Out

3 NC NC NC

4 GND

Signal Ground GND

Signal Ground COM

5 UC_RS232_TXD Transmitted Data

NC Out

6 UC_RS232_RXD Received Data

NC In

7 NC UC_RXD_P In

8 NC UC_RXD_N In

Page 27: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-27

Appendix C: Protection Information

General

This appendix provides information about the FibeAir IP-10 protection equipment.

Protection Patch Panel

In IP-10 protection configurations, a protection patch panel is used to connect the units and provide protection

switching.

As shown in the illustration above, the protection panel (in the middle) provides the ports used to link the two

IP-10 units for protection switching when a system fault occurs.

Page 28: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-28

Panel Components

The following illustration shows the panel components.

Part Numbers

The part numbers for the MDR cables are as follows:

16 x E1/T1 MDR Connector:

WA-0276-0, 0.6 meters

User 16 x E1/T1 MDR Connector:

WA-0277-0, 5 meters

WA-0278-0, 10 meters

WA-0309-0, 25 meters

Optical splitter used for GbE 1+1 systems (see the following section):

AO-0038-0

AO-0039-0

AO-0059-0

AO-0060-0

IDU #2 16xE1/T1

MDR Connector

IDU #1 16xE1/T1

MDR Connector

User 16xE1/T1

Open-Ended MDR Connector

User Optical GbE

LC/LC Connector

IDU #1 4 x FE

Straight RJ-45 Connectors

User FE Open-Ended Cross RJ-45 Connectors

IDU #2 4 x FE

Straight RJ-45 Connectors

Page 29: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-29

GbE Optical Splitter

The following illustration shows the rear side of the IP-10 protection panel, with the optical splitter.

The optical splitter is an LC/LC female adapter.

Optical Splitter

Page 30: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-30

Appendix D: Accessories

The following tables list the FibeAir IP-10 accessories.

Cables

Part Number Marketing Model Marketing Description

WA-0242-1 X-WSC-E1/T1 E1/T1 WSC x-ed cable

WA-0246 IDU-EXT-ALARMS-CBL-2.5m IDU External Alarms open cable 2.5m

WA-0259 CBL-16E1-CB-120-75 16E1 cable MDR/2xDB44 5m to CB-120-75

WA-0275 IDU-UC-CBL-2m User channel cable 2m D-type 9 pin male

WA-0276-0 IP10-CBL-16IO-PROT-0.6m IP-10 16 I/O port protection cable straight 0.6m

WA-0277-0 IP10-CBL-16IO-5M IP-10 16 I/O port cable open 5M

WA-0278-0 IP-10-CBL-16IO-10M IP-10 16 I/O port cable open 10M

WA-0284-0 IP10-CBL-16IO-XED-0.6m IP-10 16 I/O port crossed cable 0.6m

WA-0309-0 IP-10-CBL-16IO-25M IP-10 16 I/O port cable open 25M

Panels

Part Number Marketing Model Marketing Description

EN-0254-0 IP10-ETH-16E1-PROT-PANEL IP-10 Eth + 16E1 protection panel

EN-0256-0 IP10-ETH-16T1-PROT-PANEL IP-10 Eth + 16T1 protection panel

EN-0258-0 IP10-16E1-PROT-PANEL IP-10 16E1 protection panel

EN-0259-0 IP10-16T1-PROT-PANEL IP-10 16T1 protection panel

EN-0262-0 IP10-ETH-PROT-PANEL IP-10 Eth only protection panel

Page 31: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-31

Optical Splitters

Part Number

Marketing Model Marketing Description

Item Description

AO-0038-0 GBE-SPL-SM SM/LC Optical Splitter conn. 1300nm 50/5

1x2 Single mode Fiber Dual Windows Wideband Couplers, ±40nm, LC/LC, 1310nm,1m length, PVC 2.0mm cable (yellow), 50/50 coupling ratio.

AO-0039-0 GBE-SPL-MM-2M MM/LC Optical Splitter 62.5/125 2M

1x2 multimode mode Fiber Dual Windows Wideband Couplers, ±40nm, LC/LC, 850nm,1m length for each port, PVC 2.0mm cable, 50/50 coupling ratio

AO-0059-0 GBE-SPL-MM-1M MM/LC Optical Splitter 62.5/125 1M

1x2 multimode mode Fiber Dual Windows Wideband Couplers, ±40nm, LC/LC, 850nm,0.5m length for each port, PVC 2.0mm cable, 50/50 coupling ratio

AO-0060-0 GBE-SPL-MM-0.6M MM/LC Optical Splitter 62.5/125 0.6M

1x2 multimode mode Fiber Dual Windows Wideband Couplers, ±40nm, LC/LC, 850nm,0.3m length for each port, PVC 2.0mm cable, 50/50 coupling ratio

Optical Cables

Part Number

Marketing Model Marketing Description

Item Description

AO-0033-0 OP-SM-CBL-LC-SC-DPLX 15M

Duplex Optical Cable LC-SC SM 15M

Pairs of Fiber Patchcord Single mode- LC/SC, Length:15M, Duplex PVC 2mm cable, with LC connector type on one end and SC connector on the other end.

AO-0035-0 OP-SM-CBL-LC-SC-DPLX 3M

Duplex Optical Cable LC-SC SM 3M

Pairs of Fiber Patchcord Single mode- LC/SC, Length:3M, Duplex PVC 2mm cable, with LC connector type on one end and SC connector on the other end.

AO-0041-0 OP-SM-CBL-LC-SC-DPLX 1M

Duplex Optical Cable LC-SC SM 1m

DUPLEX LC-SC (Tx TO Tx) SM 9/125 YELLOW COLOR R-9D-1-P, 13MM, 1M

AO-0044-0 OP-MM-CBL-LC-SC-DPLX 2M

Duplex Optical Cable LC-SC MM 2M

DUPLEX FIBER OPTIC MM PATCH CORD WITH LC/UPC-SC/UPC (Tx TO Tx) 62.5/125, ORANGE COLOR, 2M, 3MM O.D.

AO-0045-0 OP-MM-CBL-LC-SC-DPLX 10M

Duplex Optical Cable LC-SC MM 10M

DUPLEX FIBER OPTIC MM PATCH CORD WITH LC/UPC-SC/UPC (Tx TO Tx) 62.5/125, ORANGE COLOR, 10M, 3MM O.D.

AO-0048-0 OP-MM-CBL-LC-LC-DPLX 0.5M

Duplex Optical Cable LC-LC MM 0.5M

DUPLEX FIBER OPTIC MM PATCH CORD WITH LC/UPC-LC/UPC (Tx TO Tx) 62.5/125 ORANGE COLOR, 0.5M, 2MM O.D.

AO-0055-0 OP-SM-CBL-LC-SC-DPLX 10M

Duplex Optical Cable LC-SC SM 10m

DUPLEX LC-SC (Tx TO Tx) SM 9/125 YELLOW COLOR, 3MM, 10M

Page 32: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-32

Part Number

Marketing Model Marketing Description

Item Description

AO-0057-0 OP-SM-CBL-LC-SC-DPLX 5M

Duplex Optical Cable LC-SC SM 5m

DUPLEX LC-SC (Tx TO Tx) SM 9/125 YELLOW COLOR, 3MM, 5M

AO-0066-0 OP-MM-CBL-LC-LC-DPLX 3M

Duplex Optical Cable LC-LC MM 3M

DUPLEX FIBER OPTIC MM PATCH CORD WITH LC/UPC-LC/UPC (Tx TO Tx) 62.5/125 ORANGE COLOR, 3M, 2MM O.D.

AO-0067-0 OP-MM-CBL-LC-LC-DPLX 6M

Duplex Optical Cable LC-LC MM 6M

DUPLEX FIBER OPTIC MM PATCH CORD WITH LC/UPC-LC/UPC (Tx TO Tx) 62.5/125 ORANGE COLOR, 6M, 2MM O.D.

AO-0071-0 OP-SM-CBL-LC-LC-DPLX 3M

Duplex Optical Cable LC-LC SM 3M

Pairs of Fiber Patchcord Single mode- LC/LC, Length:3M, Duplex PVC 2mm cable, with LC connector type on one end and LC connector on the other end.

Optical Adaptors

Part Number

Marketing Model Marketing Description

Item Description

AO-0042-0 OP-SM-LC-LC-ADPT-SMPLX

Adaptor Female/Female LC-LC Simplex

SM SIMPLEX LC-LC SM ADAPTOR

Page 33: IP-10 IDU Installation (Rev b.01)

FibeAir® IP-10 IDU Installation Guide 1-33

Appendix E: Fan Tray Replacement

Fan Tray Replacment Procedure

If it is necessary to replace the fan tray in the IDU, replace it as follows:

1. Remove the current fan tray by releasing the safety screw and removing the tray.

2. Insert the new fan tray entirely in its place and tighten the safety screw.