Invisible Units

2
® transport refrigeration system Transblock ® INVISIBLE UNITS SFZ RANGE 007 • 008 • 009 MODELS Hot gas defrost 3 Compressor suction 4 Compressor discharge 5 Condenser inlet 8 1 2 3 4 5 6 7 8 9 Condenser outlet 9 Internal evaporator unit 2 1 “Optional” mains connection unit 7 Compressor 6 New "stand-by" option available as range completion

description

SFZ range: 007 008 009 models New "stand-by" option available as range completion

Transcript of Invisible Units

Page 1: Invisible Units

®

transport refrigeration system

Transblock®

INVISIBLE UNITSSFZ RANGE

007 • 008 • 009 MODELS

Hot gas defrost3

Compressor suction4

Compressor discharge5

Condenser inlet8

1

2

3

45

6

7

8

9

Condenser outlet9

Internalevaporator unit

2

1

“Optional” mains connection unit7

Compressor6

New "stand-by" option available as range completion

Page 2: Invisible Units

®

Direct drive invisible units

©2014 ZANOTTI S.p.A. Via Martin Luther King 30, Pegognaga (MN) - Italy | Tel. +39 0376 5551 | Fax +39 0376 536554 | www.zanotti.com | e-mail [email protected]

0DEP

205

• Sep

tem

ber 2

014

DATI TECNICI • TECHNICAL DATA

SFZ007 SFZ008Funzionamento • Operation Strada • Road Rete • Stand-by Strada • Road Rete • Stand-by

Refrigerante • Refrigerant R134A R404A

Potenza frigorifera • Cooling capacity

0° 1.630 W 1.350 W 2.215 W 1.600 W

-20° - - 1.088 W 750 W

Consumo nominale correnteRated current consumption 10,5 A / 0,13 kW 22,6 A / 0,27 kW

Sbrinamento • Defrost Aria • Air Gas caldo • Hot gas

Compressore • Compressor131 cc 131 cc

23,6 cc 30,7 cc

Portata d’aria evap. • Evap. air flow 910 m3/h 910 m3/h

Freccia d’aria • Air throw 3 m 3 m

SFZ009Funzionamento • Operation Strada • Road Rete • Stand-by

Refrigerante • Refrigerant R404A

Potenza frigorifera • Cooling capacity

0° 3.217 W 2.300 W

-20° 1.850 W 1.100 W

Consumo nominale correnteRated current consumption 12 A / 2,5 kW

Sbrinamento • Defrost Gas caldo • Hot gas

Compressore • Compressor163 cc

35,7 cc

Portata d’aria evap. • Evap. air flow 840 m3/h

Freccia d’aria • Air throw 4 m

VOLUME CELLA CAMION CONSIGLIATO • RECOMMENDED TRUCK BOX VOLUME

SFZ007 SFZ008 SFZ009*Tc 0 °C 0 °C 20 °C 0 °C 20 °C

*Ta +30 °C +40 °C +30 °C +40 °C +30 °C +40 °C +30 °C +40 °C +30 °C +40 °C

Vol. 10 m3 7 m3 14 m3 11 m3 10 m3 7 m3 21 m3 16 m3 17 m3 12 m3

New "stand-by" option for invisible units

Mantenimento della temperatura a veicolo fermoMiglior CX del veicolo poichè l'unità condensante è posizionata internamente

Maintaining temperature in "stand-by" modeInternal condensing unit improves vehicle CX

ENG

IT

I dati sono da ritenersi provvisori, resa frigorifera attenuta secondo condizioni ATP in laboratorio ZanottiData are to be considered provisional, cooling capacity obtained in occordance with ATP requirements in Zanotti laboratories

©Copyright Zanotti Spa All rights reserved. Technical data, descriptions, and pictures are to be considered provisional and not binding. Zanotti Spa reserves the right to bring such a literature, on technical and commercial grounds, at any time and without notice, any change supposed to be convenient, still being unchanged the basic features of the equipments.

©Copyright Zanotti Spa Tutti i diritti sono riservati. Dati tecnici, descrizioni e immagini sono da considerarsi provvisori e non vincolanti. Zanotti Spa pubblica il presente documento su base tecnica e commerciale, riservandosi il diritto di modificane il contenuto senza preavviso, lasciandone inalterati i contenuti basilari.

LEGENDA • LEGEND

Tc temperatura cellacell temperature

Ta temperatura ambiente ambient temperature

Vol. volumevolume

funzionamento stradaroad operation

funzionamento retestand by operation