Intralink Presentation

37
a leading telecommunication Solutions Partner

Transcript of Intralink Presentation

Page 1: Intralink Presentation

a leading

telecommunication

Solutions Partner

Page 2: Intralink Presentation

INTRALINKINTRALINKWorkshop Workshop –– July 2008 July 2008 Current Product OverviewCurrent Product Overview

Page 3: Intralink Presentation

Presentation OutlinePresentation Outline

� Product presentation

� INTRALINK – Functionality

� INTRALINK - Equipment Overview

� Conclusions

Page 4: Intralink Presentation

A Leading Microwave Point to Point Solution

Page 5: Intralink Presentation

Presentation OutlinePresentation Outline

� INTRALINK - Functionality

� INTRALINK – Equipment Overview

� Conclusions

Page 6: Intralink Presentation

INTRALINK: A Flexible & Cost efficient INTRALINK: A Flexible & Cost efficient

Point to Point SolutionPoint to Point Solution

RangeRange

SDH/PDH/ETHISR

CapacityCapacity

PDH/ETHIDR-LC

A Solution to Match Every Need

Page 7: Intralink Presentation

INTRALINK characteristicsINTRALINK characteristics

• A complete homogeneous family from 7 GHz up to 38 GHz.

• Compact indoor / outdoor architecture (1RU height indoor unit).

• Intelligent Modular design IDU for flexible configurations (PDH/ ETH-SDH-ETH)

• Common ODU for PDH/SDH/ETH traffic

• High spectrum efficiency with QPSK, 16QAM, 32QAM, 64QAM and 128QAM.

• Super PDH functionality with up to 63xE1

• Integrated E1 – Switch With Add-Drop functionality

• E1 or Ethernet Protected Ring formation

• Ethernet capacity up to 311Mbps with 5xGbE interfaces.

Page 8: Intralink Presentation

INTRALINKINTRALINK product portfolio

INTRALINK INTRALINK

seriesseries

ISR indoor unit

Modular

Integrated /

No- integrated antennas

IDR LC indoor unit

Compact

ODU

Full range frequency bands

Common HW for PDH/SDH/ETH

A Leading Microwave Point To Point solution

Page 9: Intralink Presentation

Scalability /Configuration flexibilityScalability /Configuration flexibility

• Compact design

• Small capacity

• Minimum cost solution

Edge Node Aggregation Node

Scalable network nodes

• Nodal configuration

• Complex architectures

• E1 / Ethernet / SDH

Complex network architecturesComplex network architectures

• Compact design

• Capacity scales to high

• Multi-protocol / Multi-

configuration

• Ring architecture w’ E1

add/drop

Page 10: Intralink Presentation

A complete homogeneous family from A complete homogeneous family from

7GHz up to 38GHz7GHz up to 38GHz

126037.00 ÷ 39.5038GHz

100821.90 ÷ 23.6023GHz

101017.70 ÷ 19.7018GHz

420, 490, 72814.40 ÷ 15.3515GHz

26612.75 ÷ 13.2513GHz

119, 1267.90 ÷ 8.508GHz

154, 1617.11 ÷ 7.907GHz

Duplex Spacing [MHz]Frequency Band [GHz]Frequency

Full Range Coverage of Frequency Bands

Page 11: Intralink Presentation

Super PDHSuper PDH functionalityfunctionality with up to 63xE1with up to 63xE1

←← 64QAM 64QAM →→ ←← 128QAM 128QAM →→←←QPSK/16QAM QPSK/16QAM →→

IDR LC PDH/ETHIDR LC PDH/ETH

(Compact 1RU)(Compact 1RU)

ISR PDH/SDH/ETH ISR PDH/SDH/ETH (Modular 1RU)(Modular 1RU)

• Different IDUs support the following capacities

8xE1 / 16xE1 42xE1 / 48xE1 8xE1 / 16xE1 42xE1 / 48xE1 48xE148xE1 63xE1 / STM63xE1 / STM--1 1

16 / 32Mbps 84 / 90Mbps 9616 / 32Mbps 84 / 90Mbps 96Mbps 1Mbps 1555Mbps5Mbps

CapacityCapacity

ModulationModulation ←← 32QAM 32QAM →→

Page 12: Intralink Presentation

Network Reliability / ResiliencyNetwork Reliability / Resiliency

• Equipment protection

� Redundant indoor unit modules

� Redundant outdoor units

• Microwave propagation protection

� Space Diversity

� Frequency Diversity

• Network protection

� E1 Ring with 1+1 protection

� Ethernet ring with RSTP protection

� SDH protection (in combination with MSPP platform)

INTRALINK products ensure End – to – Reliability throughout the network

Page 13: Intralink Presentation

Presentation OutlinePresentation Outline

� INTRALINK - Functionality

� INTRALINK – Equipment Overview

� Conclusions

Page 14: Intralink Presentation

A Leading Microwave Point to Point Solution

IDUIDU--LCLCCompact Indoor Unit Compact Indoor Unit ––

Edge NodeEdge Node

Page 15: Intralink Presentation

INTRALINK IDUINTRALINK IDU--LC key featuresLC key features

Low Cost Edge Node solution

Frequency & capacity agility

Modulation agility

PDH/ ETH interfaces

Low Cost Edge node solution

• Cost efficient 1 + 0 terminal

• Compact design with 1U height

PDH / ETH interfaces

� 2 - 16 x E1 G.703

� 1 x 100Base-T user

payloads (1 – 32 Mbps)

Frequency / Capacity agility

• 7, 8, 13, 15, 18, 23, 38GHz

• Up to 16 E1 Max capacity

Modulation Agility� QPSK / 16QAM for spectrum

efficiency and system robustness

� Multiple channel widths: 3.5MHz, 7MHz & 14MHz

PDH / ETH radio relay unitPDH / ETH radio relay unit

Page 16: Intralink Presentation

IDUIDU--LC (Edge node) typesLC (Edge node) types

16QAM/16E1 (14MHz)

QPSK/4E1 (7MHz)

Cost effective edge node

Page 17: Intralink Presentation

IDUIDU--LC (Edge node) interfacesLC (Edge node) interfaces

2 x 10/100 2 x 10/100 BaseTBaseT

Traffic ports Traffic ports

(RJ(RJ--45)45)

2 x 10/100 2 x 10/100 BaseTBaseT

NMS ports (RJNMS ports (RJ--45), 45),

Local and RemoteLocal and Remote

PSUPSU

2 x DB2 x DB--25 for 25 for

2x RS232 2x RS232

19.2kbps EOW +19.2kbps EOW +

Alarms Alarms

Wave guide Wave guide

Connector Connector

NN--typetype

RJRJ--11 for VOW11 for VOW

End to EndEnd to End

6868--pin SCSI pin SCSI

connector connector

for 16E1sfor 16E1s

DBDB--99

CLICLI

Activity Activity

LEDsLEDs

Alarm & SynchAlarm & Synch

LEDsLEDs

Cost effective edge node

Page 18: Intralink Presentation

A Leading Microwave Point to Point Solution

July 9, 2008

ISRISRModular Indoor Unit Modular Indoor Unit --

””Pay as you growPay as you grow”” PlatformPlatform

Page 19: Intralink Presentation

Modular DesignModular Design

•Single 1U Unit to support E1 to STM-1

•Future – proof platform

•Flexible configuration PDH/SDH/ETH

Flexible 1U modular unit - Pay As You Grow

Power supplyPower supply

modulemodule

Master I/O Traffic Master I/O Traffic

interfaces moduleinterfaces module

--StandardStandard

--Enhanced w’ STMEnhanced w’ STM--1 1

Mux/demuxMux/demux

--SuperPDHSuperPDH

--GbEGbE

Expansion modulesExpansion modulesModem moduleModem moduleController Controller

modulemodule

16E116E1

21E121E1

STMSTM--1 opt1 opt

STMSTM--1 el1 el

Page 20: Intralink Presentation

INTRALINK ISR (SDH/PDH/ETH) featuresINTRALINK ISR (SDH/PDH/ETH) features

PDH/ SDH / ETHERNET Capabilities in 1RU Indoor Unit

Power

Supply

Module

Second

Power

Supply

Module

(Optional)

Master I/O Module

Standard : 16xE1 + 2 x FE

Enhanced: 16xE1 + 2 x FE

+ STM-1 Mux /DMux

SuperPDH: 42 x E1 + 2 x FE

GbE: 5 x GbE + 2 x E1

Controller

Module

Modem and

IF/Telemetry

Module

Second

Modem and IF/Telemetry

Module (Optional)

1x STM-1 Mini

I/O Module (Optional)

E1/T1

Expansion I/O

Module

16 or 21x E1

(Optional)

Page 21: Intralink Presentation

INTRALINK ISR (SDH/PDH/ETH) featuresINTRALINK ISR (SDH/PDH/ETH) features

PDH/ SDH / ETHERNET Capabilities in 1RU Indoor Unit

1-2 x E1/T1

RJ-48C

RJ-45 GUI Telnet/SSH

/ SNMP

RJ-45

10/100 BaseTX

Ethernet

-48VDC

DB-15

CLI RS-232/ 38kBps

+ Alarms

ODU

Connector TNC

USB Port

(future use)

3-16 x E1/T1

High Density

60 PIN Molex

RJ-45

64 kbps

Voice ORW

RJ-45

RS-422

64K Data

Data ORW

STM-1 optical S-1.1 SC

Or Electrical BNC 75Ohm

Cable + connectors

up to 20dB loss

To ODU

Page 22: Intralink Presentation

INTRALINK ISR (SDH/PDH/ETH) featuresINTRALINK ISR (SDH/PDH/ETH) features

• 1U unit, for 1+0, 1+1 and 2+0 (East/ West) single chassis configurations

• Frequency & capacity agility

� Options for 16 / 32 / 42 / 58 / 63 x E1s – PLUS - Ethernet

� 1 xSTM-1 ( 2 x STM-1 by end of year with 56MHz ODU)

� 310Mbps Ethernet Max throughput capacity

• QPSK/16QAM/32QAM/64QAM/128QAM modulation

• Optional integrated MUX/DEMUX module to extract up to 63xE1 from STM-1

� STM-1 to 63xE1, applicable to ring topologies (2+0 East West configurations)

� 10/100Mbps or 10/100/1000Mbps Interfaces with Jumbo frames QoS and VLAN support

• Upgradeable from:

� 1+0 to1+1

� PDH to Super PDH

� PDH to SDH

PDH / SDH / ETHERNET Capabilities in 1RU Indoor Unit

Page 23: Intralink Presentation

INTRALINK: INTRALINK: CrosspointCrosspoint E1 switch / 2+0 ringE1 switch / 2+0 ring

PDH ring with E1 add/drop

Standard

Controller

Module

+

E1

Optional

cards

ISR

ISR

ISR ISR

Page 24: Intralink Presentation

INTRALINK: INTRALINK: CrosspointCrosspoint E1 switch with STME1 switch with STM--1 1

PDH ring with STM-1 / E1 add/drop

Enhanced

Controller

Module

+

STM-1

Optional

card

ISR

ISR

ISR ISR

Page 25: Intralink Presentation

NodalNodal architecture (Aggregation Node)architecture (Aggregation Node)

From / To Node X1

ISR

Connections on E1 or

STM-1 level

ISR 1+1

ISR

IR - MSPP

From / To Node Xn

• In combination with MSPP (iR-MSPP or other)

• Realization of complex architectures

• SDH terminal multiplexer and add /drop function

• SNCP path protection / MS protection

• Simultaneous Ethernet transport

• iR-MSPP : 273 E1 non blocking switching capacity, full duplex

• Up to 6 x STM-1 interfaces

• Or 63 E1 interfaces

• GFP / LCAS for Ethernet Transport

Page 26: Intralink Presentation

INTRALINK: Comparative table INTRALINK: Comparative table

2xRS-232 Data orderwire/

Voice orderwire

2x10/100BaseT NMS

Max Throughput Capacity:

32Mbit max

Supported Topology: 1+0

Up to 16xE1 traffic interfaces

Single board chassis

IDR LC

(Compact 1RU)

Same HWOutdoor Unit

1xRS-422/RS-232/ VOW

2x10/100BaseT NMS/

1 Mbps wayside

Max Throughput Capacity:

155Mbit (PDH / SDH)

or 310Mbps Ethernet

Topologies: 1+0 / 1+1/ 2+0 /

Ring / More Complex with MSPP

Up to 63xE1 traffic interfaces

MODULAR architecture:

Controller Unit, I/0 Unit, Modem

Indoor Units

ISR

(Standard 1RU)

Page 27: Intralink Presentation

A Leading Microwave Point to Point Solution

July 9, 2008

ODU ODU -- CHPCHPPDH/SDH High PDH/SDH High

Performance Outdoor UnitPerformance Outdoor Unit

Page 28: Intralink Presentation

INTRALINK ODUINTRALINK ODU--CHP CHP

• Compact User Friendly Design

– Smallest ODU in the industry

• 4 -6 Kgs

• Symmetrical design

• Easy to install and align

• - 50 deg Celcius

• High Performance PDH/SDH

– QPSK/16QAM/32QAM/64QAM/128QAM

– Excellent Performance

• Up to 114,5 / 108,5/ 94 dB system gain for QPSK/16QAM/128QAM

• Rates up to 155 Mbps, channels 3.5 / 7 / 14 / 28 MHz

• ATCP support

• Integrated Antennas & Protection

– 1, 2, 4, 6 ft Integrated Antennas

– Symmetrical & Asymmetrical Couplers

Page 29: Intralink Presentation

A Leading Microwave Point to Point Solution

Point To Point Radio ManagementPoint To Point Radio Management

PRMSPRMS

Page 30: Intralink Presentation

ManagementManagement

� SNMP based Element management is provided with the following functionality:

•Configuration and fault management

•Performance security management

•Northbound interfaces (CORBA, CLI)

� Terminals can be accessed through Serial/Ethernet modem interface using any

of the following modes of user interfaces :

•Command Line Interface (TELNET, SSH)

•Web Interface

•SNMP Agent

Page 31: Intralink Presentation

What is PRMS?

Point To Point Radio Management System enables the rapid deployment,

efficient supervision and consistent management of elements constituting the

network

•• Fault managementFault management

•• Configuration managementConfiguration management

•• Performance managementPerformance management

•• Security managementSecurity management

Page 32: Intralink Presentation

Management System: PRMS

Page 33: Intralink Presentation

Presentation OutlinePresentation Outline

� INTRALINK - Functionality

� INTRALINK – Equipment Overview

� Conclusions

Page 34: Intralink Presentation

INTRALINK highlights for a costINTRALINK highlights for a cost--efficient efficient

backhaulingbackhauling

• Capacity and Modulation Agile Radio Terminal

� Scaleable capacity : 4xE1 to 63xE1 to STM-1 in 1U unit

� Flexibility : PDH - PDH/Ethernet - SDH - Ethernet in 1U unit

� Ethernet traffic up to 311 Mbps in 1U unit

• E1 Traffic Cross Connection in 1U unit

• Ring formation in 1U unit

• E1 Add-Drop Multiplexer with STM-1 interface in 1U unit

• Nodal configuration with MSPP

• Local / Remote Management: Web-based, SNMP, Windows, CLI

The Flexible FutureThe Flexible Future--Proof PlatformProof Platform

Page 35: Intralink Presentation

INTRACOM TELECOMINTRACOM TELECOM

19.7 km 19.7 km MarkopoulouMarkopoulou Ave.Ave.

19002 Peania, Athens, Greece19002 Peania, Athens, Greece

TT +30 210 667 1000+30 210 667 1000

FF +30 210 667 1001+30 210 667 1001

www.intracomwww.intracom--telecom.comtelecom.com

Page 36: Intralink Presentation

Integrated ETH InterfaceIntegrated ETH Interface

•Native Ethernet transport support

•Pass through forwarding of VLAN – tagged packets

•Variable length Ethernet packets – support of jumbo frames

•Implementation of Ethernet rings

•Weighted priority queues for implementing QoS

•Port based

•VLAN Tag Priority (802.1q)

•IPV4 TOS/ Diffserv

Integrated Ethernet Interface

Page 37: Intralink Presentation

600Mbps MAX Ethernet capacity 600Mbps MAX Ethernet capacity

configurationconfiguration

IDU 1

IDU 2

IDU 1

IDU 2

ODU

ODU

ODU

ODU

ODU

ODU

ODU

ODU

NMS

GigE

NMS

GigE

IDU Master Trunk 1

IDU Slave Trunk 2

4+0 East/East: Each IDU is paired with two ODUs.

� Each ODU points in the same direction on a different channel.

� Maximum Capacity is 600 Mbps

� Uses 128-QAM capable ODUs and use of 28 MHz channels

� Protected system, loss of link only reduces bandwidth by 25%