Intouch 9.0 v

download Intouch 9.0 v

If you can't read please download the document

  • date post

    31-Oct-2014
  • Category

    Technology

  • view

    997
  • download

    5

Embed Size (px)

description

 

Transcript of Intouch 9.0 v

  • 1. Configuration Manual For SCADAIntouch v9.0

2. Configuration Manual for SCADA Table of Contents Table of ContentsChapter 1 Intouch v9.0 .................................................................................................... 3 1-1 OPC Server ............................................................................................................ 4 1-2 Connect OPC Client to OPC Server through Intouch v9.0 ..................................... 5 2 3. Chapter 1Intouch v9.0 4. Configuration Manual for SCADAIntouch v9.01-1 OPC ServerPlease create tags according to the Configuration Manual.Later, click [ File ] [ Make Active ] to activate new created configuration file. 4 5. Intouch v9.0 Configuration Manual for SCADA1-2 Connect OPC Client to OPC Server through Intouch v9.0Start OPCLink. [ Start ] [ Program ] [ Wonderware ] [ IO Servers ] [ OPCLink ][ Configure ] [ Topic Definition ]Click [ New ] to add new Topic5 6. Configuration Manual for SCADAIntouch v9.0OPC Link Topic DefinitionDescription ColumnDescription Topic NameTopic Name Node Name Remote OPC Server (IP or name of Remote PC/ Please skip this column if there is no remote pc be connected with.) OPC Server Name The OPC Server to be connected with OPC PathGroup of OPC Server 6 7. Intouch v9.0 Configuration Manual for SCADAHere takes Modbus as an exampleFirst, Define the Topic Name as Test_Modbus.Please select OPCTechs.Modbus30DA.3.7 8. Configuration Manual for SCADA Intouch v9.0Click Browse on OPC Path to choose the Data Item, and then click [ OK ].Click [ OK ]8 9. Intouch v9.0Configuration Manual for SCADAClick [ Done ].Do not close OPClink, Please continue the following issue without closing OPClink.9 10. Configuration Manual for SCADA Intouch v9.0Start InTouch program. [ Start ] [ Programs ] [ Wonderware ] [ InTouch ]create anew project.Select [ Access Names ] on the tree view.Click [ Add ] to create a new Access Names.10 11. Intouch v9.0Configuration Manual for SCADADescription of Access Name Configuration Column Description Access Access name Node NameRemote OPC Server(IP or name of Remote PC/ Pleaseskip this column if there is no remotepc be connected with.) Application Name Application name Topic Name Topic name of the application Which protocol to use When to advise server11 12. Configuration Manual for SCADAIntouch v9.0The configuration of OPC Link connection. Please select [ OK ]. ColumnDescription AccessTest Node Name Please skip this column if there is no remote pc be connected with. Application NameOPCLINK Topic NameTest_Modbus (Topic Name of OPCLINK) Which protocol to use Suite Link When to advise server Advise only active itemsA test project will be created. 12 13. Intouch v9.0 Configuration Manual for SCADASelect [ Tagname Dictionary ] to create new tags connected to Access Names.Create a new Tag.Type in AI01 in [ Tagname ]; then click [ Type ] to select the Tag Type.13 14. Configuration Manual for SCADA Intouch v9.0Please select source .Click [ Access Name ] to select the Access Name you need.Select the test to be connected, and then click [ Close ].14 15. Intouch v9.0Configuration Manual for SCADAType in the Tag connected to OPC Server. The format of Tag name must follow: {Tag Type}+{Tag Name} DDiscrete ValueIInteger ValueRReal ValueMMessage ValueIAI_01Click [ Save ].15 16. Configuration Manual for SCADAIntouch v9.0Select [ Text ] and type ####.Press the right key of the mouse selecting [ Animation Links ]. 16 17. Intouch v9.0Configuration Manual for SCADAClick [ Analog ] to select the data source.Double click on the Tagname.17 18. Configuration Manual for SCADA Intouch v9.0Please select AI01 .Click [ OK ].18 19. Intouch v9.0 Configuration Manual for SCADAStart Intouch program.19