About Stationary Vacuum SystemsSubstantial savings can be realized by installing a Dustontrol system.Following are some example installations;• All grinders and fi nishing tools in an FRP production facility are

equipped with suction casings and connected to a central extraction system. Capture of the dust at source contributes to an improved working environment, higher productivity - shorter clean-up, cleaner process and improved product quality.

• Cleaning of saws, mills, lathes and other process machines with a centralized system. More effi cient production, cleaner machines, faster production, effi cient lubrication use and a higher return on prompt scrap through more eff ective collection. Your people spend less time on tasks that do not add to the bottom lne

• Extraction of chips and lube directly at the source: Cleaner parts thoughout the production process, and a cleaner environment on the shop fl oor. Cleaner machines mean better functioning lube systems,

better function means cooler running tools. Cooler tools mean better parts and longer tool life.

• Fume extraction with extraction integrated welding guns.Reduced exposure to fume, healthier welders, higher productivity.

• Vacuum cleaning systems and air cleaning equipment in bakeries reduces airborne fl our dust that is dangerous to health and can cause asthma: Th e health and safety regulations are met and at the same time the workplace environment and overall effi ciency is improved. Fewer health problems from employees will aff ect insurance rates positively.

• Extraction/vacuum systems in pharmaceutical production for source extration in the process and for cleaning of production machinery and areas. To eliminate hazardous dusts generated during pharmaceutical production is a must from a health perspective as well as a product quality issue.

31

Stationary Vacuum Systems3

3

Page 5: Internationalenglish 2011 - Dustcontrol

1

2

3

4

5

7

1

3

2 8

5

6

74

1. Complete Extraction System.2. Vacuum Producer.3. Filter Unit.

4. Pre-Separators.5. Installed Tubing System.6. Work Place Equipment.

7. Cleaning Accessories and Suction Casings.8. Main System Control.

32

Stationary Vacuum Systems 3

Page 6: Internationalenglish 2011 - Dustcontrol

1 IntroductionTo attain the desired effi ciency and benefi ts with an extraction system, the system must be complete; from the suction casing to the vacuum producer to the control system. All the components of the system are equally important in implementing its functionality.

2 Vacuum ProducersTh e vacuum producer is the heart of the system. Here the vacuum is created that drives the system. In Dustcontrol extraction systems, the vacuum level is gene rally from 6–40 kPa.Our normal source extraction and vacuum cleaning systems use turbo-pumps. Th is device has an ideally suited characteristic capacity for this type of system. Vacuum level increases as more resistance is pre sented, an important quality in minimizing the possibility of blockages in the tubing system. For applications involving fume and light dust, such as paper, radial blowers are used. Th ese have larger air-fl ows and operate at a lower, relatively constant vacuum level.Our turbopumps and radial blowers have very high quality built-in silencing, see technical speci fi cations.

3 Filter UnitsAn extraction system should always be equipped with a fi lter unit. Dustcontrol fi lter units separate coarse material in the cyclone body of the unit and fi ne dust in an internal arrangement of conical pleated cartridge fi lters. Pleated fi lters have very high fi lter areas in relation to their physical size. Th e fi lter units therefore have high capacity while maintaining compact overall dimensions. Filters are cleaned with reverse pulse which results in very eff ective cleaning, long fi lter life and low maintenance.Normally the fi lter units are equipped with a plastic sack for collection of the extracted material but other types of discharge arrangements can also be installed.

4 Pre-SeparatorsPre-separators can be used in all applications where the extracted material is coarse or voluminous. Th ese can be placed in the actual workplace for separate handling or recovery of the extracted material, or centrally.Pre-separators separate material from the air fl ow using cyclonic action or with inertial separation. Inertial separators are generally confi gured as containers with the inlet and outlet in the same wall of the container. When the air fl ow changes direction abruptly, separation occurs for the particles with higher relative mass. When pre-separation is used to accommodate higher material volumes it is also important to consider the type of material discharge to be used. Dustcontrol off ers a range of diff erent standard options including; screw compaction, airlocks or container collection.

5 Tubing SystemTh e tubing system transports the material from the point of collection to the central unit. Dust is generally abrasive, some more than others,

The Complete System therefore the standard material thickness of the tubing system is 1.5 mm. Applications with fume and light dust use reinforced spiral duct. Stainless tubing systems and extra abrasion resistant fi ttings are available.Dustcontrol has a very compre hensive assortment of tubing fi ttings and installation hardware. Th is gives greater fl exibility in design and installation of our tubing systems. Our mechanical jointing system makes alterations and additions very easy to carry out. Cones, branch pipes and bends are manufactured in EPDM- and NBR- rubber. Th e components are hard-wearing and sound deadening.

6 Work Place EquipmentAn extraction system is sized for only those outlets which are to be used simultaneously. Th is is in order to maximize effi ciency and minimize the size of the central unit. All outlets must have some type of closure, either a fl ap valve or shutter. Th ese can be manually actuated, such as fl ap valves or manual shutter valves, or automatically controlled for actuation only when extraction is required.Th e Flexpipe can be used for fume extraction, high fl exibility and small diameter allow it to be placed very close to the fume source.Overhead suspension arrangements such as swing-arms and hose reels can increase the usefulness of the system, increase ergonomics and minimize potential trip hazards from hose left on the fl oor.When large volumes of material are to be introduced into the system, stainless fl oor funnels can be used from which the material is then extracted.

7 AccessoriesA hose must have many qualities, the foremost for the operator however is fl exibility. It should also be tough enough to withstand the abrasion created when transporting the extracted material. Hose selection should include consideration of abrasion, chemical and heat resistance as well as conductivity to static electricity. Dustcontrol has a comprehensive assortment of hose types, diameters and hose connections.Cleaning tools, suction casings and special nozzles are those compo-nents that are actually used to cap ture the dust. Th e design and eff ective ness of these will determine the effi ciency and acceptance of the entire system. Th is demands a varied and comp lete assortment of specially designed products. Dustcontrol has that. If a standard pro-duct does not exist, we have the capacity to design and manufacture it.

8 Control SystemsMotor starters and System Control Panels control the operation of the system, both operation of the vacuum producers and cleaning of the fi lter. A variety of other control functions can be installed as required. Even with a rather basic control system, intelligent features can be included to clear coarse material in the main tubing runs or control vacuum production and therefore energy consumption according to actual requirements.

33

Stationary Vacuum Systems3

3

Page 7: Internationalenglish 2011 - Dustcontrol

Planning and Design of Extraction SystemsTh e following points must be considered and a clear defi nition must be developed before design of the system can be undertaken.

• Determine the function of the system – source extraction, cleaning or pneumatic transportation. In many cases it can be wise to equip the system for diff erent functions apart from the main function of the system, for example; cleaning.

• Choose the outlet confi guration. Determine for each outlet the type of extraction equipment required as well as the type of closure ( automatic or manual ). To determine this, a detailed study of the types of activities in each work place must be undertaken.Determine the number of outlets in simultaneous use. Th e system will be designed for a maximum number of users at any point in time. In larger systems, the number of simultaneous users in diff erent parts of the system should be determined.

• Decide the routing of the tubing runs and location of the central unit. Consider the degree of diffi culty for installation; ceiling height, wall and roof perforations, moving equipment into place, etc.

• Consider the type of material to be extracted, the degree of abrasion, risk for explosion and risk for clogging, etc.

• Determine the volume of material to be collected per unit time. Select the type of pre-separator and type of material handling for collected material. Material discharge etc, must be determined according to the customer requirement.

• Select the type of control system to be used, for example; programmable start – stop or work place start - stop.

• Determine electrical and compressed air supply requirements for the system. Indicate location of the requirement and assign responsibility for the supply and installation.

Tube SizingTh e tube dimensions are selected on the basis of maintaining the correct transportation velocity in all parts of the tubing system. It is necessary not only to consider the velocity in the main runs but also in all the branches of the tubing system. Th e tube diameter should be selected so that a velocity of > 20 m/s is maintained for particle transportation – for fume, a lower velocity of > 12 m/s is used.

As an exception in normal systems, we recommend that the smallest tube diameter be 76 mm, even if the minimum transportation velocity recommended is not maintained.

System DesignAlways try to maintain a star confi gu ration for the tubing system where the main runs are of more or less equal length leading to the central unit in the middle.A balancing of the system must be done to ensure that air-fl ows are suffi cient for proper extraction at all points in the system and that transportation velocities are maintained.In a system for fume extraction, a large main duct can distribute the system’s capacity. Any combination of outlets can be used. Conversely, in a system for the pneumatic transportation of heavy material, the transportation velocity must be maintained. In these systems, one open outlet per tubing run is the norm (usually 76 mm).

Typical tubing confi guration for heavy cleaning and material transportation

Turbopump

Pre-separator

Note: Only one outlet per pipe run can be used

at the same time.

Typical tubing confi guration for light dust and fume

Turbopump or

Radial Blower

Filter Unit

34

Stationary Vacuum Systems 3

Page 8: Internationalenglish 2011 - Dustcontrol

AB

C

D1 D2 D3

E F G

Ø50

Ø38Ø32Ø25

kPa/m Δ p

2,5

2,0

1,5

1,0

0,5

0Q

kPa Δ p

3

2

1

0

8 m6 m4,5 m3,5 m2,5 m

0 100 200 300 400 m3/h

0 100 200 300 400 m3/h

kPa/m Δ p

0, 3

0, 2

0, 1

0 0 400 800 1200 1600 m3/h

Ø76

B

C

Ø50

Ø108Ø100

D

Q

Ø125

Q

3xØ76

1xØ160

2xØ108

3xØ108

2xØ160

1xØ250

3xØ160

2xØ108

3xØ76

1xØ160

3xØ108

2xØ160

1xØ250

3xØ160

200 400 600 800 1000 1200 1400 1600 m3/h

0 1000 2000 3000 4000 m3/h

kPa Δ p5

4

3

2

1

0

kPa Δ p6050403020100

10

20

30kW P

50 Hz, 60 Hz14

16

12

910

11 13

15

1214

16

9 10 11 13 15

kPa Δ p5

4

3

2

1

0 0 1000 2000 3000 4000 5000 m3/h

Th e system’s capacity is determined by the worst case – usually the maximum number of users with the highest air-fl ow collectively. If you are unable to determine which scenario gives the highest pressure loss, several calculations may need to be performed.

Design fl ows in m3/h given for outlets in use simultaneously. Pressure loss is calculated from the outlet at the lower left.

Pressure Loss, Suction Hoses

Pressure Loss, Swingarms

Pressur Loss, Tubing

Pressure Loss, F 20000 and F 30000

Pressure Loss, S 32000, S 34000, S 34000X

Turbopumps

System Part Q Calculation Δ p

A Suction Casing, hand-held Tool 200 m3/h Δp = 3.5 kPa 3.5 kPa

B Hose Ø 38x3m 200 m3/h Δp = 1.2 kPa/m x 3 m = 3.6 kPa 3.6 kPa

C Swingarm 4.5 m 200 m3/h Δp = 0.7 kPa 0.7 kPa

D1 Tubing Ø 76 x 10 m + bends (bend is counted as 2 m) 200 m3/h Δp = 0.02 kPa/m x (10 + 4) m 0.28 kPa

D2 Tubing Ø 108x15 m 750 m3/h Δp = 0.06 kPa/m x 15 m 0.9 kPa

D3 Tubing Ø 159x25 m + 4 bends 1350 m3/h Δp = 0.02 kPa/m x (25 + 8) m 0.7 kPa

E Pre Separator, F 20000 1350 m3/h inlet Ø 160: Δp = 1.1 kPa 1.1 kPa

F Filter Unit, S 32000 1350 m3/h inlet Ø 160: Δp = 1.8 kPa 1.8 kPa

Total pressure loss 12.6 kPa

With safety factor 10% Δp = 12.6 kPa x 1.1 = 13.9 13.9 kPa

Design capacity: 1350 m3/h @ 13.9 kPa

Vacuum Producer Selection: TPR 50, 30 kW

35

Stationary Vacuum Systems3

3

Page 9: Internationalenglish 2011 - Dustcontrol

Pressure loss calculations for this type of system are infl uenced by a number of diff erent factors and exact calculations can be very complex. In general, the following calculation can be used. With material loadings greater than 1:1 (= 1,2 kg material per m³ air), a practical test should always be done. Calculate the pressure loss for clean air from the extraction point to the pre-separator according to the calculation on the previous page. Calculate the added pressure loss that the transported material will result in according to the following:Δpmaterial=Δp0x m1/(Q x 1,2) (kPa)where Q is air-fl ow in m³/hm1 is material fl ow in kg/h Calculate then the pressure loss for the remaining system (pre-separator to vacuum producer). Add this value together with the pressure loss value from the previous calcu lation. Add the safety factor to the sum of these.

Pneumatic Material TransportationTo transport larger volumes of coarse dust or other material requires a series of special considerations to minimise the possibility of clogs in the tubing system or problems discharging collected material. Analyse both the type and volume of material according to the following considerations:

1. Material Volume• Average volume litre/hour ..............................................................

• Max. volume litre/hour ..................................................................

2. Material Characteristics ..............................................................

• Description of material ...................................................................

...........................................................................................................

• Material created by ........................................................................

.....................................................................................................

• Particle size distribution .................................................................

...........................................................................................................

• Bulk density ...................................................................................

• Max. moisture content ....................................................................

• Hygroscopic material? ....................................................................

• Chemically aggressive material? ......................................................

• Explosible material ......................................................................... 3. Abrasion and Clogging• Abrasive material ............................................................................

• Bridging ........................................................................................o

Test with a paper cone for the included angle that facilitates free fl owing of the material.

4. Operating Conditions

• System in operation ...................................................... hours/day

• Filter cleaning a) after shut down ........................................................................

b) during operation .......................................................................

• material to be introduced into system with ......................................

........................................................................................................... ( suction lance, fl oor funnel, etc. )

• transport distance ....................................................................... m

• number of bends ...................................................................... pcs

• Th e system should be designed for transportation velocities from 20 – 25 m/s. Higher velocities result in increased wear. Ensure minimum transportation velocity is main tained in the tubing system (only one outlet in use per run).

• Select tools and accessories which allow suffi cient transport air into the system.

• Minimize the number of 90° bends. Never install two 90° bends closer together that 25 times the tube diameter.

• Select horizontal or vertical tubing runs. Avoid sloping runs where material ”corning” may occur. In sloping runs material will have a tendency to precipitate and run down against the direction of fl ow in the bottom of the tube.

• Select, hose, tubing and separator with consideration to abrasion.• Select material discharge with consideration to the consistency and

volume of material to be discharged.• Plan emptying intervals and routines (plastic bag or container).

Example:Suction Lance 2 kPaHose 8 kPaTubing 3 kPaSum 13 kPaAir-fl ow 350 m3/hMaterial fl ow 100 kg/hAdded pressure loss from material Δp= 13 x 100/(350 x 1.2) = 3 kPaPre-separator 2 kPaFilter unit 2 kPaSum 4 kPaSum tot 13+3+4=20 kPa Safety factor 10% =>Required negative pressure = 22 kPa

Pressure Loss Calculation in a Material Transport System

Confi guration of Extraction Systems for Material Transportation

36

Stationary Vacuum Systems 3

Page 10: Internationalenglish 2011 - Dustcontrol

Th e DC 11-Module is a complete central unit for source extraction and industrial cleaning. Th e unit can manage just about every kind of dust and chip you can imagine, and when properly equipped, your coolants and emulsions too.

With the DC 11-Module, we deliver a complete central unit from the factory, plug and play - easy to install. We tailor it exactly to your specifi c needs. Th is is possible due to an options based selection process. Th e DC 11-Module has been designed to produce more capacity/HP and service up to six normal extraction points or several cleaning outlets at a time. We’ve worked hard to get the standard sound level to just 65 dB(A). Need a HEPA fi lter? - Just select it as an optional extra.Th e discharge system can be chosen in accordance with the material to be handled; making it easy for your people to maintain their equipment. Th e DC 11-Module is also suitable for source extraction and general cleaning in smaller production areas. Note that the unit can connect to many extraction points, as long as the number of users does not exceed the maximum capacity. For energy saving and reliable remote activation of operation, the DC 11-Module is also available with the DC Green System. For futher information , see page 128.

Optimized Stand-Alone UnitTh e design of a source extraction system is always based on the specifi c need at each work place. It is then possible to design and install a central unit for several, or many, extraction points. Alternatively, maybe a stand-alone unit for a particular area is the best choice. Th e advantage with stand-alone solutions is that you attain cleaner production one step at a time - as production requires it and as budget allows it. Th e DC 11-Module becomes part of the work cell or production machine and can be part of the fl exibility of modern lean manufacturing and fast change-overs from part to part.Th e DC 11-Module is developed to fulfi l the demands of a local solution.

DC 11-Module

37

Stationary Vacuum Systems3

3

Page 11: Internationalenglish 2011 - Dustcontrol

HEPA FiltersTh e fi ne fi lter separates a large quantity of the fi ne dust, but has a limited effi ciency on the smallest particulate. In order to capture this particulate, the unit should be equipped with a HEPA fi lter. We always recommend that a HEPA fi lter be used when the system air is returned to the plant environment. With designated or hazardous dust we recommend the use of a HEPA fi lter even if the system air is to be vented out of the plant. (Note: Always be aware of and comply with local regulations.)

Safe ChangeWhen dealing with designated or hazardous dust, the fi lters (fi ne and HEPA fi lter), should be able to be changed without exposure to the personnel or plant environment. Th e same applies for changing the bags. By choosing the safechange solution, which includes the HEPA fi lter, a system is designed that keeps negative pressure in the cyclone during this operation. By putting plastic bags over the fi lters before they are changed, protection against dust can be maintained.

Control PanelTh e electrical function is built into the machine. Th e unit is started manually with a start button, automatically when any of the extraction points are opened and micro-switches are used or by clock control. Filter cleaning is automatic after shutdown of the vacuum. With the DC Green System option you get on-demand control for saving energy, see page 128. You can also choose if the unit should be a fi xed installation or mobile and be delivered with a Euro connection (5.5/7.5 kW).

Vacuum ProducerTh e vacuum producer is a direct driven turbo pump. It is highly durable and has minimal service requirements. Th e characteristic of this type of vacuum producer makes it excellent for use with a VSD. With the frequency converter option the performance capacity will be optimised.

Filter UnitTh e fi lter unit separates the larger particles in the cyclone and the fi ner dust in the pleated conical fi lter. Th e fi lter is cleaned very eff ectively with reverse pulse. Normally, compressed air is used for fi lter cleaning, but manual fi lter cleaning that does not require compressed air can be chosen as an alternative. Th e fi lter unit separates everything from fi ne dust to chips and fl uids.

Outlet/ExhaustFor fi xed installed extraction systems it is always recommended to exhaust the air out of the building if a HEPA is not used. In doing that, all residual particulate and any gases extracted are expelled from the building. With the help of a HEPA fi lter, almost all the particles can be eliminated. In a large plant, exhausting to atmosphere can sometimes be diffi cult. In these cases exhaust directly at the unit can be considered. Extra duct work and optional silencing is available to suit the installation.

Discharge of materialDischarge of dust, fl uids and heavy material is done under the cyclone. A number of diff erent solutions can be chosen. Th e most common is plastic bag or container. Containers are available with a variety of volumes. Containers can be equipped with wheels, internal plastic bag, level glass and a drain tap for lubricants.

Mobile UnitTh e DC 11-Module is designed with a pallet format chassis so it can easily be moved with a fork truck or pallet jack. By choosing to equip the unit with wheels and handle, a mobile unit is created that even with its large size and weight, is possible to move easily by hand on the production fl oor. Th ere is also the possibility to create a semi-mobile unit where the unit is confi gured as a portable but docked to an installed tubing system. When it is required elsewhere, un-dock it, and wheel it away.

38

Stationary Vacuum Systems 3

Page 12: Internationalenglish 2011 - Dustcontrol

p

With

out s

yste

m c

ontr

ol

141x

x6x,

141

xx9x

, 141

xxA

x

With

dire

ct s

tart

con

trol

141x

xFx

With

mot

or c

ontr

olle

r sof

t sta

rt

141x

xGx

With

freq

uenc

y in

vert

er c

onst

ant s

peed

141x

xLx

DC

Gre

en S

yste

m

141x

xNx

Direct driven three phase turbopump - long life time x x x x xSound absorbent around vacuum producer x x x x xFilter unit with separation of particles in cyclone and fine fraction particles in pleated filter x x x x xMain switch on panel* x xSoft start for turbopump xFrequency inverter for start/stop and speed control x xConstant rpm set from display xDemand control according to DC Green System xManual start and stop from panel front x x x xProgrammable clock start/stop x x optionPrepared for remote start with micro switches x x x xControl for filter cleaning with air pulse x x x xButton for manual filterclening x xPrepared for filter cleaning during operation x x x xSolenoid valve for filter cleaning in filter unit 24VAC 24VDC 24VDC 24VDC 24VDC

Alarm indication x x x xTimers adjusted from display x x x xPressure level adjusted from display xThermal protection x** x** x xVacuum valve x x x xRoof hood x*** x*** x*** x***

*/ Please note that when main switch is not included it should always be assembledon the supply on the wall beside the unit.**/ Not for 5.5 kW***/ Only 5 kW, 5.5 kW and 7.5 kW

DC 11-Module delivered complete with

39

Stationary Vacuum Systems3

3

Page 13: Internationalenglish 2011 - Dustcontrol

* Sound level with extra silencer on the outlet 5 dB (A) lower the given fi gure.

Air pulse fi lter cleaning all models

Air consumption 4 l/s, 4 bar

Hose connection 6 mm

Filter material in pleated polyester all models

Part No 4292

Total fi lter surface 8.4 m2

Degree of separation EN 60335-2-69 part 1 > 99.9 %

HEPA fi lter (optional)

Part No 42136

Total fi lter surface 5.2 m2

Degree of separation EN 1822-1 HEPA H13 99.95%

Max temp fi lter 80 oC

Electric connection for units without control panel 24 VAC. Note! Units with integrated control panel use 24 VDC.

TECHNICAL DATA 5.5 kW 7.5 kW 10 HP 11 kW P 15 HP P 11 kW S 15 HP SMotor 50 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz

RPM 3000 rpm 3000/rpm 3600 rpm 3000/rpm 3600 rpm 3000/rpm 3600 rpm

Inlet/Outlet Ø108/100 Ø108/100 Ø108/100 Ø108/100 Ø108/100 Ø108/100 Ø108/100

Max dp 22 kPa 22–18 kPa 22 kPa 22 kPa 20 kPa 40 kPa 43 kPa

Nominal pressure 18 kPa 18–17 kPa 18 kPa 18 kPa 18 kPa 30 kPa 32 kPa

Max Q 450 m3/h 450–550 m3/h 500 m3/h 800 m3/h 850 m3/h 450 m3/h 560 m3/h

Weight 200 kg 225 kg 225 kg 260 kg 260 kg 250 kg 250 kg

Sound level 1 m 60 dB(A) 63 dB(A)* 63 dB(A)* 63 dB(A) 64 dB(A) 63 dB(A) 64 dB(A)

Sound level with

frequency inverter 60-65 dB(A)* 61-67 dB(A) 61-67 dB(A)

40

Stationary Vacuum Systems 3

Page 14: Internationalenglish 2011 - Dustcontrol

14123 6 1 0Q 2 1

Base unit Filter Discharge Confi guration Special

equipment

Options DC 11-Module

Part Numbers

Example

* Not for 11 kW/15 HP

** Only DC Green System

DC 11-Module Base Unit Filter Discharge Confi guration Special

equipment5.5 kW 400 V 50 Hz without any panel 141236

5.5 kW 400 V 50 Hz with soft start panel 14123G

7.5 kW 400 V 50 Hz without any panel 141246

10 HP 230/460 V 60 Hz without any panel 1412FA

7.5 kW 380-480 V 50/60 Hz Frequency inverter Constant speed 14124L

7.5 kW 380-480V 50/60 Hz Green System 14124N

11 kW P 400 V 50 Hz without any panel 141466

15 HP P 460 V 60 Hz without any panel 1414P9

11 kW P 400 V 50 Hz with softstart panel 14146G

11 kW P 380-480 V 50/60 Hz Frequency inverter Constant speed 14146L

11 kW P 380-480 V 50/60 Hz Green System 14146N

11 kW S 400 V 50 Hz without any panel 141366

15 HP S 460 V 60 Hz without any panel 1413P9

11 kW S 400 V 50 Hz with softstart panel 14136G

11 kW S 380-480 V 50/60 Hz Frequency inverter Constant speed 14136L

11 kW S 380-480 V 50/60 Hz Green System 14136N

Filter Options

Standard 0

With HEPA 1

Safe change 2

PTFE 3

Discharge

Output in plastic sack (discharge cone 4706) 01

Balance valve (4706 + 7131) 02

Container 90 litre, steel, blue 16

Container 40 litre; steel, blue 0 H

Container 40 litre; steel, blue with sight glass 0 J

Container 40 litre; steel, blue with sight glass and drain tap 0 K

Container 40 litre; steel, blue with sight glass, drain tap and bottom screen 0 L

Container 40 llitre; stainless steel 0 M

Container 40 litre; stainless steel with bottom screen 0 N

Container 60 litre 0 Q

Container 60 litre; steel, blue with drain tap 0 R

Container 60 litre; steel, blue with drain tap and bottom screen 0 S

Container 75 litre; with plastic sack and wheel 2 1

Container 90 litre; steel, blue with sight glass and travers ears 2 2

Design

Compressed air fi lter cleaning 1

Manual fi lter cleaning 2

Compressed air fi lter cleaning, Mobile version 7

Manual fi lter cleaning, Mobile version 8

Options

Standard 0

Euro connection* 1

Electronic clock weekly** 4

With fl owsensor (for sep. Green System) 6

41

Stationary Vacuum Systems3

3

Page 15: Internationalenglish 2011 - Dustcontrol

42

Stationary Vacuum Systems 3

Page 16: Internationalenglish 2011 - Dustcontrol

DC 11-Module Standard • Standard fi lter • Output in plastic sack (discharge cone 4706) • Outlet, compressed air fi lter cleaning

Part No 14123G00110 DC 11-Module 5.5 kW, 400 V, 50 Hz with Softstart ControlPart No 14124L00110 DC 11-Module 7.5 kW, 380-480 V, 50/60 Hz with Frequency Converter constant speedPart No 1412FA00110 DC 11-Module 10 HP, 230/460 V, 60 Hz, USA/CAN, without Control SystemPart No 14146G00110 DC 11-Module 11 kW, 400 V, 50 Hz, with Softstart ControlPart No 1414P900110 DC 11-Module P 15HP, 460 V, 60 Hz USA/CAN, without Control SystemPart No 14136G00110 DC 11-Module S,11 kW 400 V, 50 Hz, Softstart ControlPart No 1413P900110 DC 11-Module S 15 HP, 460 V, 60 Hz USA/CAN, without Control System

43

Stationary Vacuum Systems3

3

Page 17: Internationalenglish 2011 - Dustcontrol

4 x

5 m

3 x

1 x 2 m2 x

2 x

12 x2 x

Central unit

2 x

6 x 3 m

8 x

DC 3800 Stationary

The two conductor cable for 24 V is not included in the package (electrical and connection schematic are included with the panel).

Central unit Part No Qty

DC 3800 Stationary 230/400 V 50 Hz 2.5 kW 117400 1

DC 3800 Stationary 230/460 V 60 Hz 4 HP 117408 1

Control systemsControl Panel 400 V 50 Hz 2.5 kW 8117 1

Control Panel 230 V 50 Hz 2.5 kW 8119 1

Connection PointFlap Valve Ø 50 with micro switch 8433 3

Tubing systemPipe Ø 50 (L= 3 m) 3071 6

Bend Ø 50,90° 3310 4

Bend Ø 50,45° 307311 2

Joint Ø 50 3077 8

Branch pipe 50/50 307411 2

Coupling socket 50/50 2107 2

Hose Ø 50 (L=5 m) 2401 1

Hose clamp 50-65 4219 2

Bracket 300 3008 12

Clamping band Ø 50 3107 12

Ceiling attachment (L=2 m) 9622 1

Control Panel

The package consists of:

Th e DC 3800 Stationary package is intended for installations in (for example) industrial premises, garage workshops and schools. Th e dust-separator and turbo pump are mounted on a common chassis. Th e DC 3800 Stationary package has fl ow capacity for one work place at a time, for example a 6” cup stone or cleaning with 38 mm attachments. Th e fi lter is cleaned manually with a patented reverse pulse mechanism. Th e unit can be equipped with a vacuum relief valve to allow cooling air to the pump if all outlets are closed.Th e package is complete with tubing in three metre lengths, bends, branch pipes and connection joints. Installation is simple and the tubing system is easily adaptable to most sites. Starting and stopping of the central unit occurs automatically. Starting occurs when any of the outlets are opened. Th e central unit will shut down when all the outlets are closed.

Part No 114700 DC 3800 Stationary package

44

Stationary Vacuum Systems 3

Page 18: Internationalenglish 2011 - Dustcontrol

8253

3195

40261

860

1400

kPa Pu

20

15

10

5

0

0 100 200 300

Q

m3/h

50 Hz

60 Hz

kPa Δ p

6

4

2

0

0 100 200 300

Q

m3/h

Part No 117400 220–240/380–420V, 50 Hz, 2.5 kWPart No 117408 4 HP, 230/460 V, 60 Hz, 3.0 kW USA/CANPart No 118500 220–240/380-420 V, 50 Hz,

2.5 kW Auto fi lter cleaningPart No 118504 4 HP, 460 V, 60 Hz,

3.0 kW USA/CAN Auto fi lter cleaningPart No 4314 Plastic Sack 30 litre, 50 pack

AccessoriesPart No 8253 Vacuum Relief Valve 50 mmTh e vacuum relief valve is installed on the tubing system ( inlet side ) on a branch tube. Th is delivers cooling air to the turbopump and can be adjusted for the desired vacuum level in the system.Part No 3195 Silencer 80 mm 300/180Used for exhaust silencing and also silencing of 50 mm vacuum valve. Part No 40261 Silencing CoverTh e silencing cover will reduce the sound level 4 dB.

CapacityPressure Loss Filter Unit

TECHNICAL DATA 50 Hz 60Hz

H mm 1400 1400

W mm 400 400

L mm 860 860

Weight 50 kg 50 kg

Inlet/Outlet Ø50 mm Ø50 mm

Flow at open inlet 260 m3/h 320 m3/h

Neg. pressure 20 kPa 21 kPa

Power Motor 2.5 kW 3.0 kW

Filter area, fi ne fi lter 1.8 m2 1.8 m2

Degree of separation >99.9% >99.9%

Collection sack 30 l 30 l

Sound level <75 dB (A) <75 dB(A)

45

Stationary Vacuum Systems3

3

Page 19: Internationalenglish 2011 - Dustcontrol

0,11M Ø

0,11M Ø

108MM Ø

DC Box packageTh e DC Box has been specially designed for cleaning smaller dust extractors and hand held tools. In the DC Box, dust is extracted by a DC 11-Module extraction system. Th e objects are loaded through the access doors in the end of the cabinet. Th e box is equpped with three arm access sleeves where the operator can work with objects placed in the cabinet. Th e box is equipped with compressed air and a vacuum cleaning outlet. Th e DC Box is easy to work with and fi ts any machine and tool up to approximately 1 metre in size. Th e DC Box is a complete solution including pipes and central extraction unit.Part No 114801

Th e DC Box package is delivered with the following:– DC Box basket funnel – External conveyor– DCF Mobile pre-separator – DC 11 Module 12 kW P central unit – 400 V 50 Hz System Control Panel

TECHNICAL DATA DC Box DC 11-Module 11 kW

H x W x L 2 100 x 800 x 1 600 mm 1 800 x 1000x 1 300 mm

Weight 160 kg 260 kg

Inlet/Outlet Ø 76 mm Ø 108 mm

Hose length 2 m

Reverse Pulse 4 l/s, 4 bar

Flow 600 m3/h 800 m3/h

Neg. pressure max 21 kPa

Filter area 8.4 m2

Degree of separation > 99.9%

Noise level 65 dB(A)

46

Stationary Vacuum Systems 3

Page 20: Internationalenglish 2011 - Dustcontrol