Finger safe up to IP2 60 to 1000 Amp conductors in Standard or Medium Heat cover Cover shaped to shed water and dust Horizontal conductors with contact from underside Bar length: 4.5 metres Systems up to 150 metres without expansion sections Reduced and simple maintenance SAFELEC INSULATED CONDUCTOR BARS 60 up to 1000 Amp Certificate No. FM 21334

Transcript of INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8...

Page 1: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

Finger safe up to IP2

60 to 1000 Amp conductors in Standard or

Medium Heat cover

Cover shaped to shed water and dust

Horizontal conductors with contact from

underside

Bar length: 4.5 metres

Systems up to 150 metres

without expansion sections

Reduced and simple maintenance

SAFELECI N S U L A T E D C O N D U C T O R B A R S

6 0 u p t o 1 0 0 0 A m p

Certificate No. FM 21334

Page 2: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC 2: Technical Data Galvanised Steel Conductor Bars; Expansion Sections Copper Conductor Bars; Expansion Sections Aluminium / Stainless Steel Conductor Bars; Expansion Sections Joints Jointing Compound Powerfeeds: End Powerfeed; Joint Powerfeed Hanger Clamps: Standard Mount; Lateral Mount Hanger Clamps: with Insulator Anchor Clamps End Caps Pick Up Guides Isolation Sections: Galvanised Steel Bar; Copper Bar; Aluminium / Stainless Steel Bar Collectors Collector Shoe + Holder Collector Bracket Brackets: Single Sided Bracket; Double Sided Bracket; Web Bracket; Girder Clamp System Dimensions Component Dimensions Component Dimensions (Continued) Component Dimensions (Continued)

SAFELEC Insulated Conductor BarsTypical ApplicationsSelection of ConductorsTechnical Data

SAFELEC

ONTENTS

PAGE:

5678999

10111112121314141515

16171819

3344

5

SAFELEC 3: Technical Data Copper Conductor Bars; Expansion Sections Aluminium / Stainless Steel Conductor Bars; Expansion Sections Joints Jointing Compound Powerfeeds: Joint Powerfeed Powerfeed Sections: Copper Bar; Aluminium / Stainless Steel Bar Hanger Clamps: Standard Mount; with Insulator Anchor Clamps End Caps Isolation Sections: Copper Bar; Aluminium / Stainless Steel Bar Collectors Collector Shoe + Holder Collector Bracket Brackets: Single Sided Bracket; Double Sided Bracket; Web Bracket; Girder Clamp System Dimensions Component Dimensions

202122232323242525262627272828

2930

20

V BAR: Technical Data Copper Conductor Bars; Expansion Sections; Isolation Sections Aluminium / Stainless Steel Conductor Bars; Expansion Sections; Isolation Sections Joints Powerfeeds: Joint Powerfeed Hanger Clamps: with Insulator Anchor Clamps End Caps Collectors Collector Shoe + Holder Component Dimensions Notes page Notes page Notes page

3132333434343434353536373839

31

C

Page 3: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

NSULATEDI ONDUCTORC ARSBSAFELECINSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain, the SAFELEC range ensures a high level of reliability. It has been designed to meet the safety standards demanded in industry.

Advantages of conductor bars:

- Ability to feed several moving machines from the same

conductor system

- Suitable for high amperage

- Feed points can be placed at any location

- Compactness

- Long system length possible

- Suitable for both indoor and outdoor use

SAFELEC features:

- Easy installation, reduced and simple maintenance

- Protection degree IP2, finger safe

- Insulating covers shaped to shed water and dust

- Standard PVC cover for normal temperatures

- Medium Heat cover available for high ambient temperatures

- Expansion sections not required for runs less than 150 m

- Max travel speed: 200 m/min

SAFELEC complies with the following international standards:

NFC 20-010, NFC 63-010, NFC 32-070, VDE 0470,

BSEN 60529, DIN 53438

Range of application:

Workshop cranes, iron and steel industry, railways,

leisure industry, mines etc.

YPICALT PPLICATIONSA

3

Conveyor System

Multipole Feed System

Bridge Construction Crane

Roller Coaster

Water Treatment Works

Page 4: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

ECHNICALT ATAD

SAFELEC

ELECTION OFS ONDUCTORSC

L

L/2

L/4

L/6 L/6

L/2

L/10 L/10

The maximum permissible continuous current rating of the conductor bardepends on the duty factor of the cranes and the maximum ambient

temperature Ta. It can be established using the following formula:

3-Phase ACSingle Phase ACContinuous current DC

Where:³U: volt drop in Volts³U%: volt drop in % of nominal voltageUn: nominal supply voltage in VoltsI: maximum current in AmpsD: see opposite diagramR: resistance in Ohms per metreZ: impedance in Ohms per metre

³U = 3 x I x D x Z³U = 2 x I x D x Z³U = 2 x I x D x R

Volt drop calculation ³U:

³U% = (³U x 100) / Un

End feedD = L

Feed point at L/10 and L/2 from each endD = L/10

Feed point at L/6 from each endD = L/6

Feed point at each endD = L/4

Centre feedD = L/2

FACTOR “K”

Standardcover

250C 1.000

0.905

0.798

0.674

0.775

0.707

0.632

1.118

1.011

0.892

0.754

0.866

0.791

0.707

1.291

1.168

1.030

0.870

1.000

0.913

0.816

1.581

1.430

1.261

1.066

1.225

1.118

1.000

2.236

2.023

1.784

1.508

1.732

1.581

1.414

350C

450C

550C

650C

750C

850C

Medium Heatcover

Duty

Ta

100% 80% 60% 40% 20%

I allowable = nominal current x K

4

Page 5: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

ECHNICALT ATAD

Material PVC

180 KV/cm

1011ž

>1015ž/cm

840C

Self extinguishing

54%

1.5 g/cm3

BAYBLEND

240 KV/cm

>1014ž

>1016ž/cm

1200C

Self extinguishing

24%

1.15 g/cm3

Dielectric strength

Surface resistivity

Volume resistivity

Vicat softening temperature

(never expose PVC cover totemperatures in excess of 80oC)

Flame-test

Oxygen index

Specific density

CONDUCTOR BAR COVER STANDARD MEDIUM HEAT

CONDUCTOR BAR GALVANISED STEEL ALUMINIUM / STAINLESS STEEL

COPPER

Nominal current

Cross sectional area

Maximum system voltage(AC) (contact Insul-8 for other voltages)(DC) (contact Insul-8 for other voltages)

Resistance R (for DC) at 200C (ž/m)

Impedance Z (for AC) at 200C (ž/m)

Maximum allowable ambient temperature for 100% duty cycle

Bar length

Support pitch Standard

Lateral

Minimum pitch centres Standard

Lateral

Expansion sections: not required for runs less than

Minimum bending radius: (horizontal only)

60A

50mm2

1000V

1000V

0.003584

0.003604

250C

4.5m

1500mm

1125mm

43mm

60mm

150m

1.5m

100A

63mm2

1000V

1000V

0.002867

0.002891

250C

4.5m

1500mm

1125mm

43mm

60mm

150m

1.5m

125A

93mm2

1000V

1000V

0.001933

0.001968

250C

4.5m

1500mm

1125mm

43mm

60mm

150m

1.5m

160A

50mm2

1000V

1000V

0.000342

0.000364

250C

4.5m

1500mm

1125mm

43mm

60mm

150m

1.5m

250A

63mm2

1000V

1000V

0.000274

0.000300

250C

4.5m

1500mm

1125mm

43mm

60mm

150m

1.5m

400A

93mm2

1000V

1000V

0.000184

0.000221

250C

4.5m

1500mm

1125mm

43mm

60mm

150m

1.5m

200A

104mm2

1000V

1000V

0.000301

0.000325

250C

4.5m

1500mm

1125mm

43mm

60mm

150m

1.5m

315A

120mm2

1000V

1000V

0.000261

0.000288

250C

4.5m

1500mm

1125mm

43mm

60mm

150m

1.5m

400A

156mm2

1000V

1000V

0.000199

0.000234

250C

4.5m

1500mm

1125mm

43mm

60mm

150m

1.5m

An accurate choice of conductors can be made when all the following information is known:- The type of current: single or three phase AC ; continuous (DC)- The maximum current power and duty cycle- The allowable volt drop for the machines being supplied- The ambient temperature- Environment (dusty, coastal, humid, acidic etc.)

5SAFELEC 2

SAFELEC 2

Page 6: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

ALVANISEDG TEELS ONDUCTORC ARSB

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

XPANSIONE ECTIONSS

Expansion sections are required on all systems over 150m long.

The maximum gap of the expansion section is 50mm.

The expansion section is 4.5m long and is installed in place of one length of

conductor bar.

CURRENT RATING 60A 100A 125A

2.34

310002

310001

2.76

310102

310101

3.76

310202

Medium Heat cover(grey)

310003 310103 310203310056 310156 310256

310201

EarthPhase

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 60A 100A 125A

3.06

310008

310007

3.32

310108

310107

4.20

310208

Medium Heat cover(grey)

310009 310109 310209310058 310158 310258

310207

EarthPhase

Standard Phase cover

Standard Earth cover

Medium Heat cover

Expansion section310007

6 SAFELEC 2

Page 7: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 160A 250A 400A

2.76

310302

310301

3.04

310402

310401

4.40

310502

Medium Heat cover(grey)

310303 310403 310503310356 310456 310556

310501

EarthPhase

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 160A 250A 400A

3.28

310308

310307

3.86

310408

310407

4.74

310508

Medium Heat cover(grey)

310309 310409 310509310358 310458 310558

310507

EarthPhase

Standard Phase cover

Standard Earth cover

Medium Heat cover

ONDUCTORCOPPERC ARSB

XPANSIONE ECTIONSS

Expansion sections are required on all systems over 150m long.

The maximum gap of the expansion section is 50mm.

The expansion section is 4.5m long and is installed in place of one length of conductor bar.

Expansion section310307

7SAFELEC 2

Page 8: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

LUMINIUMA TEELSTAINLESSS/ ONDUCTORC ARSB

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

XPANSIONE ECTIONSS

Expansion sections are required on all systems over 150m long.

The maximum gap of the expansion section is 50mm.

The expansion section is 4.5m long and is installed in place of one length of

conductor bar.

CURRENT RATING 200A 315A 400A

2.12

310602

310601

2.18

310702

310701

2.50

399102

Medium Heat cover(grey)

310603 310703 399103310656 310756 399156

399101

EarthPhase

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 200A 315A 400A

3.23

310608

310607

3.43

310708

310707

3.80

399108

Medium Heat cover(grey)

310609 310709 399109310658 310758 399158

399107

EarthPhase

Standard Phase cover

Standard Earth cover

Medium Heat cover

Expansion section310607

8 SAFELEC 2

Page 9: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

0.049

0.044

0.032

0.2

SAFELEC

Standard Phase cover(orange)

JOINT COVER

Standard Earth cover(green)

Medium Heat cover

Heavy Duty cover

Weight (Kg)

greenblack

OINTSJ

OINTINGJ OMPOUNDC

310850

310851

310855310856

0.027

399541

Steel

JOINT Weight (Kg)

310872

Copper 310873

Aluminium 310874

Heavy Duty Copper 399549

0.225

JOINTING COMPOUND Weight (Kg)

310932

Steel Joint310872

Aluminium Joint310874

Copper Joint310873

Standard Phase cover310850

Heavy Duty Copper Joint399549

Heavy Duty Joint cover399541

Jointing compound should be applied to the contact surfaces of the joint and bar at every joint on copper and aluminium systems. One tube is sufficient for over 300 connections.

9

OWERFEEDS: END POWERFEEDP

OWERFEEDS: JOINT POWERFEEDP

Powerfeed installed in place of an end cover.

Maximum cable connection size: 16mm2

0.037

UP TO 100A Weight (Kg)

310911

End Powerfeed310911

Standard cover(orange)

Medium Heat cover(red)

Weight (Kg)

CURRENT RATING UP TO 60A UP TO 250A UP TO 400A

0.028

310066

310034

0.25

310913

310910

0.30

310915

310912Powerfeed for connection of one or two flexible cables.

310910 has single cable connection.

310912 has double cable connection.

Powerfeed is usually installed in place of a joint.

Maximum cable connection size: 60A – 10mm2

250A – 95mm2

400A – 150mm2

60A Joint Powerfeed310034

250A Joint Powerfeed310910

SAFELEC 2

Page 10: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

Lateral mount hangers are supplied with 20mm spacers to provide clearance for

joint covers.

Maximum support spacing is 1.125m.

Standard hangers are acetyl.

Maximum support spacing is 1.5m.

ANGERH LAMPS: STANDARD MOUNTC

ANGERH LAMPS: LATERAL MOUNTC

POLYCARBONATE(RED)

WEIGHT(Kg)

STANDARD(BLACK)

Single pole

Two pole

Three pole

Four pole

310824

310882

310861

310821

0.03

0.04

0.05

0.057

310829

310899

310871

310857

POLYCARBONATE(RED)

WEIGHT(Kg)

STANDARD(BLACK)

Single pole

Two pole

Three pole

Four pole

399431

399432

399433

399381

0.05

0.06

0.07

0.12

399434

399435

399436

399382Four pole

(without spacer) 310835 0.08310859

Single pole hanger310824

Two pole hanger310882

Four pole hanger310821

Three pole hanger310861

Single pole lateral mount hanger

399431

Four pole lateral mount hanger

399381

10 SAFELEC 2

Page 11: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

ANGERH LAMPS: WITH INSULATORC

11

NCHORA LAMPSC

WEIGHT(Kg)

Single pole

Single pole

Single pole

Single pole

(Black)

(Red)

Stainless steel

Two part

0.10

0.10

0.106

0.08

Two pole Two part

310918

310834

310827

399544

399627 0.174

Single pole hanger310918

Two pole two part hanger

399627

Single pole two part hanger

399544

Stainless steel hanger with

insulator310827

In particularly dusty or humid environments, hangers with insulator should be used.

WEIGHT(Kg)

Standard

With insulator

Lateral mount

Without top bolt(two required per anchor point)

0.06

0.12

0.10

0.05

310832

WEIGHT(Kg)

Heavy duty anchor 0.48399546

310969

399383

310831

Anchor clamp310832

Anchor clamp without top bolt

310831

Anchor clamp with insulator

310969

Heavy duty anchor clamp

399546

Anchor points are usually situated in the middle of a conductor system.

Additional anchor points are required for systems with expansion sections.

SAFELEC 2

Page 12: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

Transfer caps are suitable for air gaps up to 10mm.

Vertical tolerance 5mm

Horizontal tolerance 2mm

NDE APSCWEIGHT

(Kg)

Steel / copper bar

Aluminium bar

Transfer cap

0.04

0.02

0.10

310892

310893

310951

+_

+_

End cap for steel / copper bar

310892

Transfer end cap310951

12

Special collectors are required for systems where pick up guides are

fitted.

ICKP PU UIDESG

Four pole pick up guide

310929

WEIGHT(Kg)

Two pole

Single pole

Three pole

1.27

1.72

2.16

310920

399532

399502

Four pole 2.54310929

SAFELEC 2

Page 13: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

Isolation sections provide electrical separation between adjacent sections of conductor bar.

Only for use in dry, clean conditions.

The Isolation section is 4.5m long and is installed in place of one length of conductor bar.

It is recommended that Isolation sections are not fitted in earth conductors.

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 60A 100A 125A

2.71

310026

310025

3.16

310126

310125

4.19

310226

Medium Heat cover(grey)

310027 310127 310227310064 310164 310264

310225

earthphase

SOLATIONIGALVANISED STEEL BAR

ECTIONSS

COPPER BAR

ALUMINIUM / STAINLESS STEEL

Isolation section310025

13

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 160A 250A 400A

2.97

310326

310325

3.42

310426

310425

4.68

310526

Medium Heat cover(grey)

310327 310427 310527310364 310464 310564

310525

earthphase

Isolation section310325

Isolation section310625

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 200A 315A 400A

2.4

310626

310625

2.6

310726

310725

2.9

399126

Medium Heat cover(grey)

310627 310727 399127310664 310764 399128

399125

earthphase

SAFELEC 2

Page 14: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

The copper graphite shoe ensures electrical continuity, a smooth contact

with the conductor bar and a good resistance to wear.

50A and 100A collectors are supplied without cable.

Stranded cable terminal clamps are included.

250A collectors are supplied with 2 x 1m 35mm2 cable.

OLLECTORSC

Weight (Kg)

CURRENT RATING 50A 100A 250A

0.38

399360Phase

0.8

310990

2.00

34956

399380Earth - without deflector 399355

399373Earth - right hand 399340

399372Earth - left hand 399352

CURRENT RATING50A + 100APhase - red

50A + 100AEarth - green

310993Code

Weight (Kg) 0.06 0.06

399357

250A

0.28

35289

HOESOLLECTORC OLDERH+

50A Phase Collector399360

250A Collector34956

100A Collector(Earth left)

399352

100A Phase Collector310990

250A Collector Shoe and Holder

35289

50 / 100A Collector Shoe and Holder

310993

50A Collector(Earth left)

399372

14 SAFELEC 2

Page 15: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

15

OLLECTORC RACKETB

Single

13mm SQUARE

310994 310991 0.880.36Double 310898 310992 1.840.74

Single collector bracket310994

Single collector bracket310991

Double collector bracket310898

Double collector bracket310992

Weight (Kg) 25mm SQUARE Weight (Kg)

25mm square, 400mm long for use with 100A and 250A collectors.

13mm square, 200mm long for use with 50A collector.

RACKETS: SINGLE SIDED BRACKETB

310980 - to suit beam flange 80-155mm.

310982 - to suit beam flange 155-305mm.

WEIGHT(Kg)

0.66310980

0.86310982

310980

310982

RACKETS: DOUBLE SIDED BRACKETB

RACKETS: WEB BRACKETB

RACKETS: GIRDER CLAMPB

310981 - to suit beam flange 80-185mm.

310983 - to suit beam flange 185-305mm.

WEIGHT(Kg)

0.84310981

1.08310983

310981

310983

WEIGHT(Kg)

0.62310984310984

WEIGHT(Kg)

0.08310985310985

SAFELEC 2

Page 16: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

IMENSIONSDYSTEMS

16 SAFELEC 2

STANDARD HANGER CLAMPS

HANGER CLAMPS WITH INSULATOR

Page 17: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

C IMENSIONSDOMPONENT

17SAFELEC 2

60A STANDARD PHASE COVER - Expansion Section(310007)

400A JOINT POWERFEED(310912)

250A JOINT POWERFEED(310910)

END POWERFEED(310911)

ALUMINIUM JOINT(310874)

60A JOINT POWERFEED(310034)

STANDARD PHASE COVER(310850)

STEEL JOINT(310872)

250A JOINT POWERFEED

(310910)

SINGLE POLE HANGER CLAMPStandard Mount

(310824)

Page 18: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

C IMENSIONS (Continued)DOMPONENT

18 SAFELEC 2

TWO POLE HANGER CLAMPStandard Mount

(310882)

THREE POLE HANGER CLAMPStandard Mount

(310861)

END CAPfor Aluminium Bar

(310893)

TRANSFER END CAP(310951)

ANCHOR CLAMPWith Insulator

(310969)

STAINLESS STEEL HANGER CLAMP

with Insulator(310827)

FOUR POLE HANGER CLAMPStandard Mount

(310821)

ANCHOR CLAMP(310832)

SINGLE POLE HANGER CLAMP

with Insulator(310918)

END CAPfor Steel / Copper Bar

(310892)

Page 19: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

C IMENSIONS (Continued)DOMPONENT

19SAFELEC 2

STANDARD PHASE COVERIsolation Section

(310025)

SINGLE COLLECTOR BRACKET13mm square

(310994)

WEB BRACKET(310984)

DOUBLE SIDED BRACKET(310981)

DOUBLE SIDED BRACKET(310983)

SINGLE SIDED BRACKET(310980)

SINGLE COLLECTOR BRACKET25mm square

(310991)

SINGLE SIDED BRACKET(310982)

DOUBLE COLLECTOR BRACKET13mm square

(310898)

GIRDER CLAMP(310985)

Page 20: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

20 SAFELEC 3

ECHNICALT ATAD

Material PVC

180 KV/cm

1011ž

>1015ž/cm

840C

Self extinguishing

54%

1.5 g/cm3

BAYBLEND

240 KV/cm

>1014ž

>1016ž/cm

1200C

Self extinguishing

24%

1.15 g/cm3

Dielectric strength

Surface resistivity

Volume resistivity

Vicat softening temperature

(never expose PVC cover totemperatures in excess of 80oC)

Flame-test

Oxygen index

Specific density

CONDUCTOR BAR COVER STANDARD MEDIUM HEAT

CONDUCTOR BAR ALUMINIUM / STAINLESS STEEL

COPPER

Nominal current

Cross sectional area

Maximum system voltage(AC) (contact Insul-8 for other voltages)(DC) (contact Insul-8 for other voltages)

Resistance R (for DC) at 200C (ž/m)

Impedance Z (for AC) at 200C (ž/m)

Maximum allowable ambient temperature for 100% duty cycle

Bar length

Support pitch Standard

Lateral

Minimum pitch centres Standard

Lateral

Expansion sections: not required for runs less than

Minimum bending radius: (horizontal only)

500A

115mm2

1000V

1000V

0.000149

0.000189

250C

4.5m

1500mm

1125mm

60mm

60mm

150m

1.5m

800A

171mm2

1000V

1000V

0.000100

0.000154

250C

4.5m

1500mm

1125mm

60mm

60mm

150m

1.5m

1150A

339mm2

1000V

1000V

0.000051

0.000127

250C

4.5m

1500mm

1125mm

60mm

60mm

150m

1.5m

630A

277mm2

0.000113

0.000162

1000V

1000V

250C

4.5m

1500mm

1125mm

60mm

60mm

150m

1.5m

SAFELEC 3

Electric Mining Vehicles

Railway Shore

Supply

Page 21: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

21SAFELEC 3

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 500A 800A 1150A

5.40

319202

319201

7.65

319402

319401

14.34

319502

Medium Heat cover(grey)

319203 319403 319462319204 319404 319463

319501

EarthPhase

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 500A 800A 1150A

7.40

319208

319207

10.15

319408

319407

16.84

319508

Medium Heat cover(grey)

319209 319409 319466319210 319410 319467

319507

EarthPhase

Standard Phase cover

Standard Earth cover

Medium Heat cover

ONDUCTORCOPPERC ARSB

XPANSIONE ECTIONSS

Expansion sections are required on all systems over 150m long.

The maximum gap of the expansion section is 50mm.

The expansion section is 4.5m long and is installed in place of one length of conductor bar.

Expansion section319407

Page 22: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

22 SAFELEC 3

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 630A

4.23

319302

319301

Medium Heat cover(grey)

319303319304Earth

Phase

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 630A

6.50

319308

319307

Medium Heat cover(grey)

319309319310Earth

Phase

Standard Phase cover

Standard Earth cover

Medium Heat cover

Expansion section319307

LUMINIUMA TEELSTAINLESSS/ ONDUCTORC ARSB

XPANSIONE ECTIONSS

Expansion sections are required on all systems over 150m long.

The maximum gap of the expansion section is 50mm.

The expansion section is 4.5m long and is installed in place of one length of

conductor bar.

Page 23: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

23SAFELEC 3

OWERFEEDS: JOINT POWERFEEDP

OINTSJ

0.25

0.202

0.08

Standard Phase cover(orange)

JOINT COVER

Standard Earth cover(green)

Medium Heat cover

Weight (Kg)

grey

319850

319851

319472319473

0.04

Copper(up to 800A)

JOINT Weight (Kg)

319874

Copper1150A 319515

Aluminium 319873

Standard cover(orange)

Medium Heat cover(red)

Weight (Kg)

POWERFEED

0.30

319870

319909

Powerfeed has cable connection for maximum 2 x 50mm2 cables.

Joint Powerfeed319909

800A Copper Joint319874

Aluminium Joint319873

1150A Copper Joint319515

OINTINGJ OMPOUNDC

0.225

JOINTING COMPOUND Weight (Kg)

310932Jointing compound should be applied to the contact surfaces of the joint and bar at every joint on copper and aluminium systems. One tube is sufficient for over 300 connections.

Standard Phase cover319850

Page 24: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

COPPER BAR

ALUMINIUM / STAINLESS STEEL BAR

SAFELEC

24 SAFELEC 3

OWERFEEDP ECTIONSS

Standard Phase coverDouble cable connection

319918

Standard Phase cover(orange)

Standard Earth cover(green)

Medium Heat Phase cover(grey)

Weight (Kg)

SINGLE CABLE CONNECTION 500A

6.56

319913

319912

319926

Medium Heat Earth cover(grey) 319927

Standard Phase cover(orange)

Standard Earth cover(green)

Medium Heat Phase cover(grey)

Weight (Kg)

SINGLE CABLE CONNECTION 630A

5.39

319917

319916

319930

Medium Heat Earth cover(grey) 319931

Standard Phase cover(orange)

Standard Earth cover(green)

Medium Heat Phase cover(grey)

Weight (Kg)

DOUBLE CABLE CONNECTION 630A

6.83

319919

319918

319932

Medium Heat Earth cover(grey) 319934

Standard Phase cover(orange)

Standard Earth cover(green)

Medium Heat Phase cover(grey)

Weight (Kg)

DOUBLE CABLE CONNECTION 500A 800A 1500A

8.0

319915

319914

10.25

319911

319910

16.94

319524

319928 319468 319470

Medium Heat Earth cover(grey) 319929 319469 319471

319523

Standard Phase coverSingle cable connection

319912

Standard Phase coverDouble cable connection

319914

Standard Phase coverSingle cable connection

319916

Powerfeed sections are 4.5m long and should be fitted in place of a length of

conductor bar.

Suitable for connection of 1 or 2 cables up to 50mm2

Page 25: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

25SAFELEC 3

Standard hangers are acetyl.

Maximum support spacing is 1.5m.

ANGERH LAMPS: STANDARD MOUNTC

ANGERH LAMPS: WITH INSULATORC

POLYCARBONATE(RED)

STAINLESS STEEL WITH ZINC PLATED HARDWARE

STANDARD(BLACK)

Single pole

Weight

319821

0.027

319826

0.070

319829

0.030

Single pole hanger319821

Stainless steel hanger319826

NCHORA LAMPSC

WEIGHT(Kg)

Single pole

Single pole

Single pole

Single pole

(Black)

(Red)

Stainless steel

Two part

0.10

0.10

0.106

0.08

Two pole Two part

319834

319839

319827

319833

319838 0.174

In particularly dusty or humid environments, hangers with insulator should be used.

WEIGHT(Kg)

Standard

With insulator

Without top bolt(two required per anchor point)

0.06

0.12

0.05

319832

319964

319963

Anchor points are usually situated in the middle of a conductor system.

Additional anchor points are required for systems with expansion sections.

Stainless steel hanger with

insulator319827

Two pole two part hanger

319838

Single pole two part hanger

319833

Anchor clamp319832

Anchor clamp without top bolt

319963

Anchor clamp with insulator

319964

Page 26: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

26 SAFELEC 3

Isolation sections provide electrical separation between adjacent sections of

conductor bar.

Only for use in dry, clean conditions.

The Isolation section is 4.5m long and is installed in place of one length of

conductor bar.

It is recommended that Isolation sections are not fitted in earth conductors.

SOLATIONI ECTIONSS COPPER BAR

ALUMINIUM / STAINLESS STEEL

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 500A 800A 1500A

2.97

319013

319012

3.42

319426

319425

4.68

319475

Medium Heat cover(grey)

319015 319431 319476319016 319432 319477

319474

earthphase

Isolation section319425

Isolation section319311

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 630A

2.4

319312

319311

Medium Heat cover(grey)

319313319314earth

phase

WEIGHT(Kg)

End cap 0.04319892

NDE APSC

End cap 319892

Page 27: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

27SAFELEC 3

OLLECTORSC

HOESOLLECTORC OLDERH+

The copper graphite shoe ensures electrical continuity, a smooth contact with the conductor bar and a good resistance to wear.

100A collectors are supplied without cable.

Stranded cable terminal clamps are included.

250A collectors are supplied with 2 x 1m 35mm2 cable.

Weight (Kg)

CURRENT RATING 100A 250A

0.8

310990Phase

2.00

34956

399355Earth - without deflector

399340Earth - right hand

399352Earth - left hand

250A Collector34956

100A Collector(Earth left)

399352

100A Phase Collector310990

250A Collector Shoe and Holder

35289

50 / 100A Collector Shoe and Holder

310993

CURRENT RATING50A + 100APhase - red

50A + 100AEarth - green

310993Code

Weight (Kg) 0.06 0.06

399357

250A

0.28

35289

Page 28: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

28

OLLECTORC RACKETB

Single

13mm SQUARE

310994 310991 0.880.36Double 310898 310992 1.840.74

Single collector bracket310994

Single collector bracket310991

Double collector bracket310898

Double collector bracket310992

Weight (Kg) 25mm SQUARE Weight (Kg)

25mm square, 400mm long for use with 100A and 250A collectors.

13mm square, 200mm long for use with 50A collector.

RACKETS: SINGLE SIDED BRACKETB

319980 - to suit beam flange 80-155mm.

319982 - to suit beam flange 155-305mm.

WEIGHT(Kg)

0.66319980

0.86319982

319980

319982

RACKETS: DOUBLE SIDED BRACKETB

RACKETS: WEB BRACKETB

RACKETS: GIRDER CLAMPB

319981 - to suit beam flange 80-185mm.

319983 - to suit beam flange 185-305mm.

WEIGHT(Kg)

0.84319981

1.08319983

319981

319983

WEIGHT(Kg)

0.62319984319984

WEIGHT(Kg)

0.08310985310985

SAFELEC 3

Page 29: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

29SAFELEC 3

IMENSIONSDYSTEMS

STANDARD HANGER CLAMPS

HANGER CLAMPS WITH INSULATOR

Page 30: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

C IMENSIONSDOMPONENT

30 SAFELEC 3

500A STANDARD PHASE COVER - Expansion Section(319207)

COPPER JOINT(up to 800A)

(319874)

STANDARD ANCHOR CLAMP(319832)

END CAP(319892)

STAINLESS STEEL HANGER(319826)

STAINLESS STEEL HANGER CLAMP

with Insulator(319827)

JOINT POWERFEED(319909)

ALUMINIUM JOINT(319873)

SINGLE POLE HANGER(319821)

STANDARD PHASE COVER(319850)

Page 31: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

ECHNICALT ATAD

Material PVC

180 KV/cm

1011ž

>1015ž/cm

840C

Self extinguishing

54%

1.5 g/cm3

BAYBLEND

240 KV/cm

>1014ž

>1016ž/cm

1200C

Self extinguishing

24%

1.15 g/cm3

Dielectric strength

Surface resistivity

Volume resistivity

Vicat softening temperature

(never expose PVC cover totemperatures in excess of 80oC)

Flame-test

Oxygen index

Specific density

CONDUCTOR BAR COVER STANDARD MEDIUM HEAT

CONDUCTOR BAR ALUMINIUM / STAINLESS STEEL

COPPER

Nominal current

Cross sectional area

Maximum system voltage(AC) (contact Insul-8 for other voltages)(DC) (contact Insul-8 for other voltages)

Resistance R (for DC) at 200C (ž/m)

Impedance Z (for AC) at 200C (ž/m)

Maximum allowable ambient temperature for 100% duty cycle

Bar length

Support pitch Standard

Lateral

Minimum pitch centres Standard

Lateral

Expansion sections: not required for runs less than

Minimum bending radius: (horizontal only)

500A

115mm2

1000V

1000V

0.000149

0.000189

250C

6m

1500mm

1125mm

70mm

70mm

150m

1.5m

800A

171mm2

1000V

1000V

0.000100

0.000154

250C

6m

1500mm

1125mm

70mm

70mm

150m

1.5m

1150A

339mm2

1000V

1000V

0.000051

0.000127

250C

6m

1500mm

1125mm

70mm

70mm

150m

1.5m

630A

277mm2

0.000113

0.000162

1000V

1000V

250C

6m

1500mm

1125mm

70mm

70mm

150m

1.5m

31V BAR

V BARFor use in applications where regular disconnection and reconnection of current collectors is required: for example in mining and quarrying.

The specially designed profile of the insulating cover guides the collector shoe onto the sliding surface of the conductor bar, providing greater tolerance and allowing the collectors to be correctly located without direct access to the bar.

Page 32: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

Standard Phase cover

Standard Earth cover

SAFELEC

32 V BAR

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 500A 800A 1150A

6.33

319869

319250

8.55

319452

319451

15.15

319552

319551

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 500A 800A 1150A

8.93

319258

319257

11.15

319458

319457

17.75

319558

319557

ONDUCTORCOPPERC ARSB

XPANSIONE ECTIONSS

Expansion sections are required on all systems over 150m long.

The maximum gap of the expansion section is 50mm.

The expansion section is 1.5m long.

Expansion section319457

Isolation sections provide electrical separation between adjacent sections of conductor bar.

Only for use in dry, clean conditions.

It is recommended that Isolation sections are not fitted in earth conductors.

SOLATIONI ECTIONSS

Standard Phase cover (orange)

Weight (Kg)

CURRENT RATING 500A 800A 1500A

7.3

319253

9.55

319453

16.26

319553

Page 33: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

Standard Earth cover

Standard Phase cover

SAFELEC

33V BAR

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 630A

5.13

319352

319351

Standard Phase cover (orange)

Standard Earth cover(green)

Weight (Kg)

CURRENT RATING 630A

7.73

319358

319357

Expansion section319357

Expansion sections are required on all systems over 150m long.

The maximum gap of the expansion section is 50mm.

The expansion section is 1.5m long.

LUMINIUMA TEELSTAINLESSS/ ONDUCTORC ARSB

XPANSIONE ECTIONSS

Isolation sections provide electrical separation between adjacent sections of conductor bar.

Only for use in dry, clean conditions.

It is recommended that Isolation sections are not fitted in earth conductors.

SOLATIONI ECTIONSS

Standard Phase cover (orange)

Weight (Kg)

CURRENT RATING 630A

6.1

319353

Page 34: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

OWERFEEDS: JOINT POWERFEEDP

OINTSJ

SAFELEC

34 V BAR

0.25

0.202

6.08

Standard cover

JOINT COVER

Weight (Kg)

319840

0.168

Copper500/800A

JOINT Weight (Kg)

319885

Copper1150A 319515

Aluminium 319873

500/800A Copper Joint319885

Aluminium Joint319873

1150A Copper Joint319515

Standard cover(black)

Weight (Kg)

POWERFEED

0.16

319845

ANGERH LAMPS: WITH INSULATORC

NCHORA LAMPSC

WEIGHT(Kg)

Single pole Two part 0.114319844

WEIGHT(Kg)

Heavy duty anchor 0.7319843

Heavy duty anchor clamp

319843

WEIGHT(Kg)

Transfer end cap 0.08319846

NDE APSC

Single pole two part hanger

319844

Standard cover319840

In particularly dustyor humid environments,

hangers with insulator should be used

Page 35: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

35V BAR

The copper graphite shoe ensures electrical continuity, a smooth contact with the conductor bar and a good resistance to wear.

100A collectors are supplied without cable.

Stranded cable terminal clamps are included.

250A collectors are supplied with 2 x 1m 35mm2 cable.

OLLECTORSC

HOESOLLECTORC OLDERH+

Weight (Kg)

CURRENT RATING 100A 250A

0.8

310990Phase

2.00

34956

399355Earth - without deflector

399340Earth - right hand

399352Earth - left hand

250A Collector34956

100A Collector(Earth left)

399352

100A Phase Collector310990

250A Collector Shoe and Holder

35289

50 / 100A Collector Shoe and Holder

310993

CURRENT RATING50A + 100APhase - red

50A + 100AEarth - green

310993Code

Weight (Kg) 0.06 0.06

399357

250A

0.28

35289

Page 36: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

36 V BAR

C IMENSIONSDOMPONENT

800A STANDARD PHASE COVERExpansion Section

(319457)

SINGLE POLE TWO PART HANGER(319844)

JOINT COVERStandard(319840)

ALL OTHER COMPONENT DIMENSIONS AS SAFELEC 3

Page 37: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

37

NOTES

Page 38: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

38

NOTES

Page 39: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

SAFELEC

39

NOTES

Page 40: INSULATED CONDUCTOR BARS 60 up to 1000 Amp · SAFELEC SAFELEC INSULATED CONDUCTOR BARS INSUL 8 supplies electrical power feed systems for moving machinery. Easy to install and maintain,

Subsidiary companies

AUSTRALIACONDUCTIX Pty. Ltd. (Insul-8)

DandenongTel: + (61) 3 97 06 88 44Fax: + (61) 3 97 94 92 [email protected]

BENELUXCONDUCTIX Benelux

BrusselsTel: + (32) (0) 2 469 25 60Fax: + (32) (0) 2 469 29 [email protected]

GERMANY / AUSTRIACONDUCTIX GmbH

Offenbach / MainTel: + (49) 69 98 40 23 0Fax: + (49) 69 98 40 23 [email protected]

MEXICOCONDUCTIX S.de R.L. de C.V. (Insul-8)

MonterreyTel: + (52) 811 090 9013Fax: + (52) 811 090 [email protected]

UNITED KINGDOMCONDUCTIX Ltd (Insul-8)

SalfordTel: + (44) 161 848 01 61Fax: + (44) 161 873 70 [email protected]

ITALYCONDUCTIX Srl (Comes)

MilanTel: + 39 (0) 39 607 431Fax: + 39 (0) 39 607 [email protected]

TurinTel: + 39 (0) 11 45 09 007Fax: + 39 (0) 11 42 41 [email protected]

UNITED STATESCONDUCTIX, Inc. (Insul-8)

Omaha, NETel: + (1) 402 339 9300Fax: + (1) 402 339 [email protected]

Harlan, IATel: + (1) 712 755 2246Fax: + (1) 402 952 [email protected]

CANADACONDUCTIX Corp. (Insul-8)

St JérômeTel: + (1) 450 565 9900Fax: + (1) 450 432 [email protected]

CHINACONDUCTIX Ltd (Han Fa)

WuhanTel: + (86) 27 83 49 99 88Fax: + (86) 27 83 49 99 [email protected]

DELACHAUX S.A.

HEADQUARTERS

119 Avenue Louis Roche -BP15292231 Gennevilliers Cedex FRANCETel: +33 (0) 1 46 88 15 00Fax: +33 (0) 1 46 88 15 [email protected]

CONDUCTIX OPERATIONS119 Avenue Louis Roche -BP15292231 Gennevilliers Cedex FRANCETel: +33 (0) 1 46 88 15 13Fax: +33 (0) 1 46 88 15 [email protected]

Algeria, Argentina, Austria, Bahrain, Bolivia, Brasil, Bulgaria, Cameroons, Chile, China, Colombia, Congo, Ivory Coast, Croatia,Czechia, Denamark, U.A.S., Ecuador, Egypt, Finland, Gabon, Greece, Guatemala, Guinea, Honduras, Hungary, Indonesia, India, Irak,Iran, Ireland, Israel, Japan, Jordania, Korea, Kuwait, Lebanon, Madagascar, Malaisia, Mali, Mauritania, Mexico, Morocco, Netherlands,New Zealand, Niger, Nigeria, Norway, Pakistan, Panama, Paraguay, Peru, Philippines, Poland, Portugal, Rumania, Russia, SaudiArabia, Senegal, Singapore, Slovakia, South Africa, Spain, Sweden, Switzerland, Syria, Thailand, Tunisia, Turkey, Uruguay, Venezuela,Viet-Nam...

FRANCECONDUCTIX (Delachaux)

BelleyTel: + 33 (0) 4 79 42 50 00Fax: + 33 (0) 4 79 42 50 [email protected]

GennevilliersTel: + 33 (0) 1 46 88 15 23Fax: + 33 (0) 1 46 88 15 [email protected]

Countries where we are represented :

P O W E R A N D D A T A T R A N S F E R