Instructions in the Use of Radiation ... - cao.go.jp · Pull up the zipper. of the clothing all the...

12
Preparedness April 1,2018 Cabinet Office, Nuclear Emergency Response and Instructions in the Use of Radiation Protection Equipment and Radiation Measuring Instruments by Disaster Response Personnel in a Nuclear Emergency First edition:April 1,2017) Second edition:April 1,2018)

Transcript of Instructions in the Use of Radiation ... - cao.go.jp · Pull up the zipper. of the clothing all the...

Page 1: Instructions in the Use of Radiation ... - cao.go.jp · Pull up the zipper. of the clothing all the way to the neck. ③Put on the cap. ④Wear thin cotton gloves. ⑤Put shoe covers

Preparedness

April 1,2018

Cabinet Office, Nuclear Emergency Response and

Instructions in the Use of Radiation Protection

Equipment and Radiation Measuring Instruments by

Disaster Response Personnel in a Nuclear Emergency

(First edition:April 1,2017) (Second edition:April 1,2018)

Page 2: Instructions in the Use of Radiation ... - cao.go.jp · Pull up the zipper. of the clothing all the way to the neck. ③Put on the cap. ④Wear thin cotton gloves. ⑤Put shoe covers

1. Radiation Protection Equipment

(1) Protective Mask

Wear a mask to prevent inhalation of radioactive materials from respiration.A dust mask should be used for dusty radioactive materials.

(2) Protective clothing (Nonwoven fabric as protective clothing: Tyvek® etc.)To prevent radioactive contamination of the skin and regular clothing.Wear protective clothing over regular clothing to prevent adhesion of radioactive materials on the skin and clothing.

(3) GlovesTo prevent radioactive contamination of hands.Rubber gloves should be used over thin cotton gloves.In order to prevent tearing of the rubber gloves, cloth work gloves should be used over the rubber gloves depending on the case. 

To prevent radioactive contamination of the shoes.Shoe covers should be used when radioactive materials are likely to adhere to the shoes.

To prevent radioactive contamination of the head and hair.Wear a disposable cap on the head.The cap should be worn under the hood of protective clothing (nonwoven fabric as protective clothing: Tyvek ® etc.).When a helmet is used, wear it over the hood of the protective clothing.

To prevent inhalation of radioactive materials.

(4) Shoe Covers

(5) Cap

Protective clothing

Rubber Gloves

Dust Mask

Cotton Gloves

Cap

Shoe Covers

1

Page 3: Instructions in the Use of Radiation ... - cao.go.jp · Pull up the zipper. of the clothing all the way to the neck. ③Put on the cap. ④Wear thin cotton gloves. ⑤Put shoe covers

(6) Personal DosimeterTo measure exposure doseThe personal dosimeter is a device to measure the individual radiation exposure dose.There are two types of device to measure radiation exposure: the electronic type and integrating type.

(i)Electronic Personal DosimeterThe electronic personal dosimeter provides direct readings of individual radiation exposure doses.There are two types of the personal electronic dosimeter: one is reset just by turning off the power switch;

    Integrating Personal Dosimeter   Glass Badge  Quixcell Badge

The integrating personal dosimeter provides either a monthly integratedexposure dose or the exposure dose during a certain period by using the special readout device.

※Precautions for Use of Personal DosimeterElectromagnetic radiation emitted from a cellphone may induce malfunctionto an electronic dosimeter, so never place it in a pocket with a cellphone.Causing a strong shock, bending, or wetting with water must be avoided to either the electronic or integrating personal dosimeter.

(7) Radiation Measuring Instruments(i)Ambient Dose Rate Measuring Instrument (NaI Scintillation Survey Meter)The NaI scintillation survey meter can be used for measurement of the ambientdose rate from the natural background level with high sensitivity.

  

(ii)Surface Contamination Measuring Instrument (GM Survey Meter)The GM survey meter can be used for the surface contamination measurement of radioactive materials on the body, clothing, or surface of the object.

Measurement using the surface contamination measuring instrument should be kept a distance between the detector and the object surface at about 1 cmto avoid adhesion of radioactive materials on the GM tube surface.

What is Becquerel (Bq)?1Becquerel (Bq) is a unit of radioactivity.Bq is defined as disintegration of atom per second.An atom is the smallest unit that constitutes a substance.For example, a molecule of water consists of two hydrogen atoms and one oxygen atom.

the other is reset by holding down the power switch.

[Electronic Personal Dosimeter (Example)]

(ii)Integrating Personal Dosimeter

NaI Scintillation Survey Meter

GM Survey Meter

Oxygen Atom

Hydrogen

Molecule of Water H2O

Caution

Do not wet with water

Do not cause a strong shock

Do not bend

2

Page 4: Instructions in the Use of Radiation ... - cao.go.jp · Pull up the zipper. of the clothing all the way to the neck. ③Put on the cap. ④Wear thin cotton gloves. ⑤Put shoe covers

2. How to Wear Radiation Protection Equipment (Put on the instrument and equipment as shown in the following order.)

dosimeter and the integrating personal dosimeter)(A male should place the device on the breast and a female who may get pregnant should place the device on the belly.).Place the electronic personal dosimeter with its display (LCD) facing the body.※ ※depending upon the dosimeter type.Place the integrating personal dosimeter with your name facing outside.

②Put on the protective clothing. Pull up the zipperof the clothing all the way to the neck.

③Put on the cap.

④Wear thin cotton gloves.

⑤Put shoe covers on both shoes.

⑥Put on the dust mask.

Make sure that the dust mask is not upside down.Do not place the string of the mask on your ears but around the back of your head.Make sure the gap between the ridge of the nose (the foot of the nose between both eyes)and the mask is securely closed.

⑦Wear rubber gloves.Seal the gap between the rubber glove and the cuff of the protective closing using adhesive tape.If the fender of a vehicle or other sharp object may possibly be handled,put on work gloves over the rubber gloves to prevent breakage.

⑧Place the hood of the protective clothing over the cap.

①Put on the personal dosimeter(Both the electronic personal

Condition with a protective equipments.

Breast

Belly

④ ⑤

Protective Clothing

Shoe covers or rubber boots

Personal dosimeter inside protective clothing.

The end of the seal tape should be folded to form a triangle so that it can be easily removed.

③ ②

3

Page 5: Instructions in the Use of Radiation ... - cao.go.jp · Pull up the zipper. of the clothing all the way to the neck. ③Put on the cap. ④Wear thin cotton gloves. ⑤Put shoe covers

☆ When boots are used: When boots for contaminated areas are provided, use this.

 Put the bottom of the protective clothing into the boot and seal the gap with adhesive tape

☆ When a helmet is worn: When the operation is made in an area of possible   ☆ When goggles are worn flying objects or under scaffolding, wear a helmet  Wear goggles when the operation is made in over the hood of the protective clothing. dusty areas.

☆ When a half mask with a charcoal filter is used:  Wear a half mask with a charcoal filter when inhalation of radioactive iodine is likely to occur.

 ①Wrap the lower tightening string of the mask  around your neck. Wrap the upper string around the back of your head.

 ②Pull the lower string to tighten.  Squeeze the upper string to tighten around the back of your head.

 ③Make sure the mask is in tight contact with your face; .  moving the face should move the mask up and down.

 ④Inhale air with the canister of the mask blocked by your hand  and to make sure there are no air leaks between the mask and your face.

 ⑤If the mask is in close contact with your face when air is inhaled, the mask is properly placed without leakage of air.  

 Put the special socks over your personal socks.

☆ Measures for special situation ☆

① ②

4

Page 6: Instructions in the Use of Radiation ... - cao.go.jp · Pull up the zipper. of the clothing all the way to the neck. ③Put on the cap. ④Wear thin cotton gloves. ⑤Put shoe covers

3. How to Remove Radiation Protection Equipment  (Details of radioactive contamination test are explained in Section 5: Method of Radioactivity Contamination Test.)

・Because the masks and protective clothing may be contaminated with radioactive materials, removed masks and clothing should be placed in the special container marked “Contaminated” to separate them from general waste.・Remove the protective clothing slowly and gently to avoid radioactive contaminants on the clothing flying around.☆ When clothing is removed in a room, remove shoe covers (Step ⑩) first before Step①.☆ When boots are used, remove the boots before Step ①.

①When work gloves are used over the rubber gloves, remove the work gloves first.Because radioactive materials are likely to be adhered to the outer surface of the work gloves,remove each glove so that it turns inside out.   

②When a helmet is used, remove it first.Remove carefully because radioactive materials are likely to be adhered to the outer surface of the helmet.

③Remove the seal tape over the rubber gloves and then remove the gloves.Because radioactive materials are likely to be adhered to the outer surface of the rubber gloves,remove each glove so that it turns inside out.

④The surface of the mask should be tested for radioactive contamination.By measuring the amount of radioactive materials caught by the surface of the mask, whether radioactive materials were inhaled can be estimated.If there are any contamination, never remove the mask by the final step of these procedure.

⑤If there is no surface contamination on the mask,

⑦Remove the protective clothing.Because radioactive materials are likely to be adhered to the outer surface of the protective clothing, remove it slowly and gently so that it turns inside out.

⑧Remove the mask. Remove it slowly and gently because the dust (radioactive materials) caught by the mask may be dispersed.  

⑨Remove the disposable cap.

remove the hood of the protective clothing.

⑥When goggles are used, remove them.

5

Page 7: Instructions in the Use of Radiation ... - cao.go.jp · Pull up the zipper. of the clothing all the way to the neck. ③Put on the cap. ④Wear thin cotton gloves. ⑤Put shoe covers

⑪After the shoe covers are removed, radioactive contamination* of the outer soles must be tested.  

 ☆ When boots are usedAfter Step ⑨, remove the special socks and check for radioactive contamination* of the sole.

 ⑫Remove the thin cotton gloves.  ⑬Check the palms and back of both hands

        for radioactive contamination *.

⑭Check the head and hair for radioactive contamination *.

⑮Check both shoulders for radioactive contamination *.

in a continuous zigzag pattern.

⑰After checking the front of the body, check* the back of the body. Also, check* both sides of the body.

* The purpose of the radioactive contamination test is to check whether radioactive materials are attached to the body. In measuring radioactivity, place the detector at a distance of about 1 cm from the measured surface so that the detector does not directly touch the surface.

⑯Check the entire front of the body for radioactive contamination* by moving the detector

⑩Remove the shoe covers.

⑪ ⑩

6

Page 8: Instructions in the Use of Radiation ... - cao.go.jp · Pull up the zipper. of the clothing all the way to the neck. ③Put on the cap. ④Wear thin cotton gloves. ⑤Put shoe covers

4. How to Use the Measuring Instruments

(1) Use of Ambient Dose Rate Measuring Instrument (NaI Scintillation Survey Meter).The ambient dose rate measuring instrument is used to measure gamma or X rayradiation dose rate at a particular point, and the measurement is expressed in μSv/h. Use the value indicated.

Operation of the instrument depends upon manufacturers so refer to the instruction manual of the instrument used. Each instrument has its respective calibration constant.

   Measurement can be obtained by the indicated value multiplied   by calibration constant

   

    

Measurement (μSv/h) =( Indicated Value) × (Calibration Constant)When the indicated value is 0.07 and the calibration constant is 1.09; constant is usually affixed to the side of Measurement (μSv/h) = 0.07 × 1. 09 = 0.0763 ≒ 0.08 the instrument.

(2) Use of the Surface Contamination Measuring Instrument (GM Survey Meter) The surface contamination measuring instrument is used to detect whether radioactive materials are present on the surface of the human body, clothing, and other objects. The unit of measurement is the number of beta ray counted per one minute (cpm: count per minute (min-1))

    ①Press and hold the power switch for 2–3 seconds      to power on the instrument.

      the time constant changes to 3–10–30 seconds      each. Set the time constant to 3 seconds.

    ③Set the range of the analog meter to 10 k      (10,000 cpm) by pressing the range-up Button (▲).

    ④Press the Speaker Button to set the speaker to off.

     ⑤Press and hold the power switch for 2–3 seconds      to power off the instrument.

A sticker indicating the calibration

    ②Every time the TIME CONST button is pushed

Range of the Analog Meter 0.3μSv/h Full Scale

Meter Reading 0.06μSv/h

Time Constant

Indicated Value 0.07μSv/h

④Speaker Switch

Panel Layout Time Constant: Time constant changes to 3–10–30 seconds every time the TIME CONST Switch is pushed in ②

Range: The lamp illuminated in ③ shows the full scale of the analog meter. The range can be changed by pushing the range-up/down buttons (▲, ▼).

Power Switch: When pressed and held for 2–3 seconds, the instrument is powered on/off ①.

7

Page 9: Instructions in the Use of Radiation ... - cao.go.jp · Pull up the zipper. of the clothing all the way to the neck. ③Put on the cap. ④Wear thin cotton gloves. ⑤Put shoe covers

5. Method of Radioactivity Contamination Test

Radioactivity Contamination Test (Check of radioactive materials attached) Use the Surface Contamination Measuring Instrument (GM Survey Meter: With the GM tube diameter of 5 cm such as TGS-146B)

①Place a PVC sheet etc. on the floor where contamination is checked to prevent contamination.

②Protect the surface contamination measuring instrument from radioactive contamination by wrapping the instrument and the GM tube with a thin PVC sheet or food packaging wrap.

③Turn on the surface contamination measuring instrument and mute the sound.

④Set the time constant to 3 seconds and the range to 10 k (10,000 cpm).  Move the GM tube detector at a speed of about 10 cm/s to identify the spot where the needle of the analog meter swings abruptly.

Analog Meter Measuring Range (10 k)

     

Measured Value (4.53 k = 4530 cpm)Using the equation in the box below,      4530 (cpm) =15.1 (Bq/c㎡)

⑤Move the GM Detector in a continuous zigzag pattern over the entire body at a distance of about 1 cm from the head and clothing and avoiding contact.

⑥When the needle swings abruptly, move the detector slowly over the area at a speed of about 1 cm/s to identify the point where attachment of radioactive  materials is concentrated. When the point is identified, stop the detector and read the indicated digital value.

⑦Articles carried in a bag or pouch can be measured from the outside of the bag or porch. Measurement by opening the bag or pouch is not necessary.

 Calculation of Radioactivity per 1 cm2 (Bq/c㎡) from the Measured Value (cpm)(When GM Survey Meter TGS-146B etc. is used)Bq/c㎡ = Measured Value (cpm) ÷ 60 (s) ÷ Source Efficiency ÷Measurement Efficiency ÷Detection Area (c㎡)

0.5, and the Detection Area of the detector is 20 c㎡, the radioactivity at that point is about 130 Becquerel (Bq).   Calculation40,000 (cpm) ÷ 60 (s) ÷ 0.5 (Source Efficiency) ÷ 0.5 (Measurement Efficiency) ÷ 20 (Detection Area c㎡)                                                            ≒ 130 Bq/c㎡

 When the measured value is 40,000 cpm in the condition where Source Efficiency is 0.5, Measurement Efficiency is

Time Constant (3 s)

8

Page 10: Instructions in the Use of Radiation ... - cao.go.jp · Pull up the zipper. of the clothing all the way to the neck. ③Put on the cap. ④Wear thin cotton gloves. ⑤Put shoe covers

When a hand is contaminated, the contamination should be removed with wet wipes.When handling a container of wet wipes, be careful not to contaminate the container.Move the wet wipe from the outside to the center to avoid spreading any contamination.

Always use the clean face of the wet wipe.

(Note) Radioactive iodine may not be completely removed even when wiped with a wet wipe. If the area is rubbed too hard with a wet wipe, the skin may be scratched and radioactive materials may enter the body, so cover the contaminated section of the body with food wrap to contain the contamination instead of rubbing too hard. Wait until the contaminant is removed naturally over time.

If you feel anxious, consult a medical facility.

 ①Relationship between Time Constant and the Indicated Value  In the measurement, read the indication of the meter after  more than three times the time constant (seconds) has elapsed.

 The true value cannot be obtained unless more than three times  the time constant has elapsed because of the relationship

 ②Precautions in Using the Instrument  The instrument is a precision device.  Never expose the instrument to rain nor lift the device using the cable.

  between the time constant and the indicated value.

7. Precautions in Using the Instrument

6.Actions to be Taken when Contamination is Identified (Decontamination method)

63.2% at the time equal to the time constant

95% or above at three times the time

Measurement Time (s)

Time Constant

(s)

Relationship between Time Constant and the Indicated Value

9

Page 11: Instructions in the Use of Radiation ... - cao.go.jp · Pull up the zipper. of the clothing all the way to the neck. ③Put on the cap. ④Wear thin cotton gloves. ⑤Put shoe covers

Memos

Contact Points

10

Page 12: Instructions in the Use of Radiation ... - cao.go.jp · Pull up the zipper. of the clothing all the way to the neck. ③Put on the cap. ④Wear thin cotton gloves. ⑤Put shoe covers

for a nuclear emergency.

Purpose and Use of this Booklet

This booklet is intended to explain the radiation

protection equipment and its use and the method

of radiation contamination detection by disaster

response personnel for protection from radiation

in a nuclear emergency. Please use this booklet

in addition to the materials for basic training

11