Industrial Safety Systems. Made by SICK.
DIV02
Industrial Safety Systems
Author: Brad Raven
Release date: February 2008
C4000 SelectTechnical product presentation
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 2
C4000 Select
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 3
C4000 SelectContent
: Representation of technology
: Overview Technical Facts
: Mechanics
: Electrical Connections
: Configuration
: Additional options
: Which are the customer benefits of the features?
: Accessories
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 4
: Use of reliable technologies
: Opto-electronic protective device according sender/receiver principle (XC40S and XC40E)
: All variants with laser class 1 for integrated, visual alignment aid
: see special “note aligment with corner mirrors” and “integrated laser-alignment aid, background info”
: Variants with extended I/O for cascading
: Variants with endcaps with integrated LEDs
C4000 Select Description of technology
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 5
: Feature highlights : New housing profile with 3 nut grooves: Swivel-mount end caps: DIP Switch configuration : End cap with integrated LED (optional): Integrated laser and alignment bar graph system: Flexible cascading: M12x5 connectors for system and extended I/O: Condensed diagnostics: cULus approval
C4000 SelectOverview technical facts
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 6
: New housing profile with 3 nut grooves for the complete C4000 family
: profile mechanical 1:1 compatible to M4000 Area
: max. mounting flexibility
: variable sender/receiver position
C4000 SelectHousing - Mechanics
27,5
C4000 Select/M4000 Area
52
55,5
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 7
C4000 SelectNumber of Beams
Protective field height (mm)
Beam count – 30 mm resolution
300 15
600 30
900 45
1200 60
1500 75
1800 90
: 30 mm resolution (hand guard)
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 8
C4000 Select Protective Field - Dimensions
Protective field height
L1 L2 L3
300 302 425 440600 602 725 740900 902 1025 1040
1200 1202 1325 13401500 1502 1625 16401800 1802 1925 1940
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 9
C4000 SelectSystem Connection M12x4+FE
: Economically, standardized M12-connection technology
: Pin assignment always represented on type label
Pin No. Wire
Color)
Sender Receiver Description
1 Brown +24 V DC +24 V DC
Supply voltage (+)
2 White – OSSD1 Output Signal Switching Device 1
3 Blue 0 V DC 0 V DC Supply voltage (–)
4 Black – OSSD2 Output Signal Switching Device 2
5 Gray FE FE Functional Earth
[1]) Wire colors shown in this table are in accordance with SICK C4000 Select M12×5 cable accessories. When utilizing other M12×5 cable manufacturers’ cables, you may need to verify that the conductor colors shown in this table correspond with the cable that you are using.
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 10
C4000 SelectSystem/Extension Connection M12x5
: Pin assignment always represented on type label
Pin
No.
Wire
Color6)
Sender Receive
r
Description
1 Brown +24 V DC
+24 V DC
Supply voltage (+)
2 White – IN1 Safe input 1
3 Blue 0 V DC 0 V DC Supply voltage (–)
4 Black – IN2 Safe input 2
5 Gray FE FE Functional Earth
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 11
System ConnectionNo EDM or Manual Restart
: With only 5 available pins, if EDM and/or manual restart are required for the safety circuit then they need to be implemented externally
: Available SICK solutions: UE48 safety relay
: UE410 Flexi
: UE4470 safety network controller
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 12
C4000 SelectConfiguration
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 13
ConfigurationSafety Field Width
: Guaranteed range: Low 0-6 m
: High 5-19m
: Typical range: High 5-21m
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 14
ConfigurationExtended I/O
: Available at the top or at the bottom (not both)
: Cascade up to three 1800mm C4000 Selects
: Cascade a single S300 or S3000 Safety Laser Scanner
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 15
ConfigurationBeam coding
Beam Code 1
Beam Code 2
Beam Code 1
Coded and uncoded cannot be mixed
Sender and receiver beam codeconfiguration must match
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 16
ConfigurationBeam coding
This implementation has no possibility for an LED end-cap
The maximum cable lengthbetween the extensionconnector and next deviceis not to exceed 10m.
Beam Code 2
Beam Code 1
Beam Code 2
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 17
ConfigurationFloating blanking
: One or two beam floating blanking with partial object detection
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 18
C4000 SelectOptional: Integrated LED Status Indicator
: Particularly for access protection, status of device visible within 360°
: Decrease of operation downtimes: Support of alignment process at
commissioning: No additional wiring of separate LED
´s, less wiring expenditure : Not suitable for retrofit!
: Status of OSSD: RED
: GREEN
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 19
C4000 SelectIntegrated Laser and Alignment Bar Graph System
: Precise alignment of sender receiver
: Especially helpful for alignment between sender and receiver at long field widths
: No battery: Always linked with device: Customer can always control/adjust
alignment: Less service tasks for machine
manufacturer
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 20
ConfigurationNo cloning plug
: Simply match the DIP switch settings of new unit with the failed unit and re-install
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 21
C4000 Select Accessories
: Which accessories are available for the C4000 Select?
: Mounting brackets
: Connecting cables
: Additional front screens
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 22
C4000 SelectMounting Brackets
: Side bracket pivoting
Mounting kit 64 pcs. (2 019 506)
: Mounting bracket rigid
Mounting kit 14 pcs. (7 021 352)
: Mounting bracket pivoting
Mounting kit 24 pcs. (2 017 751)
: New swivel mount bracket
Mounting kit 12, 4 pcs. (2 030 510)
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 23
C4000 SelectSystem Cables
: M12-socket, 5-pin, single-ended straight female connection with flying leads
: 2 m (6 008 899)
: 5 m (6 009 868)
: 10 m (6 010 544)
: 15 m (6 029 215)
: 30 m (6 032 956)
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 24
C4000 SelectExtension Connection Cables
: M12-socket, 5-pin, double-ended male and female for extended I/O connection of another C4000 Select
: 1 m (6 029 280)
: 2 m (6 025 931)
: 5 m (6 029 282)
: M12-socket, 5-pin, single-ended male connection with flying leads for extened I/O connection of S300 or S3000
: 2 m (6 026 133)
: 5 m (6 026 134)
: 10 m (6 026 135)
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 25
C4000 SelectAdditional Front Screens
• Two additional front screens (weld spark guards) supplied for each part number.• The additional front screen fits both on the sender and on the receiver.• The additional front screen may be used only if the curved enclosure side is accessible.• An additional front screen reduces the scanning range of the system by 8%. If sender and receiver each use an additional front screen, the scanning range will be reduced by 16%.
Protective field height [mm] Part number
300 2033235
600 2033237
900 2033239
1200 2033241
1500 2033243
1800 2033245
Industrial Safety Systems. Made by SICK. Author: Heiko Kahle, Release date: 02.01.2007 / Page 26
C4000 SelectT Connector 6 030 664
M12 x 4 + FE System Connection
•Can support a “home run” cable
•Can provide additional wiring/installation savings
Industrial Safety Systems. Made by SICK.
Thank you for your attention!