Industrial Areamaster Generation 2 LED Luminaire ... · PDF fileCrossarm Mounting Bracket...

14
Industrial Areamaster Generation 2 LED Luminaire Floodlight for Ordinary Locations Applications Powerful, efficient weatherproof lighting for applications such as: — Security lighting — Production facilities — Warehouses — Processing plants — Storage areas — Parking garages and lots Features Three lumen outputs provide up to 19,500 lumens. Nominal Lumens Wattage (W) Efficacy (lpw) HID Equivalent Model Number 9,500 70 136 175W-250W IAMLGL6 15,000 110 136 250W-400W IAMLGL7 19,500 150 130 400W-750W IAMLGL8 Nominal lumen value for 5000K, detailed lumen information provided in tables. Choice of optics for optimal light distribution in a variety of applications. Separate field wiring compartment with screw terminal block for easy and secure connection (can accept UL/CSA 26-10AWG). Two ¾” NPT entries provided. Yoke bracket is designed to accommodate traditional Areamaster brackets and slipfitters for easy retrofit. Choice of color temperature (CCT); 5000K cool white or 3000K warm white. Rugged and compact housing with superior thermal design translates to long luminaire life. Heavy duty, high temperature silicone rubber gaskets. Thermal shock and impact resistant clear or frosted glass lens. Standard 6KV surge protection. Captive fasteners secure one piece lens. Field replaceable LED driver and lens cover. Ambient Temperature ranges from: — IAMLGL6, IAMLGL7 and IAMLGL8 from -40 °C to +65 °C (-40 °F to +149 °F) Options Improved safety cable design with multiple retention points, purchase separately Guard and visor available, purchase separately Slip-fitters and mounting brackets available for easy pole or wall mounting 10KV Surge Protection Floodlight Standard Materials Housing and lens door: copperfree (4/10 of 1% max.) aluminum Gaskets: silicone rubber Yoke: zinc plated HR steel Bolts: stainless steel Close up plugs: (1) aluminum provided Guard and safety cable: stainless steel Visor: Aluminum Standard Finishes Housing, lens cover, visor and yoke mount: architectural bronze polyester Related Products Round Tapered Steel Poles Hinged Steel Poled Square Tapered Steel Poles Square Steel Poles Floodlight Mounting Brackets NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X IP66/67 LED/FLOODLIGHTS: NEC/CEC ORDINARY LOCATION Visit our website at www.emerson.com or contact us at (800) 621-1506. © June 2017 232

Transcript of Industrial Areamaster Generation 2 LED Luminaire ... · PDF fileCrossarm Mounting Bracket...

Page 1: Industrial Areamaster Generation 2 LED Luminaire ... · PDF fileCrossarm Mounting Bracket (G-AM-8-CA) used with Pipe or Wall Mount Bracket (G-AM-8-WB). ... For Dark Sky Friendly design.

Industrial Areamaster™ Generation 2 LED LuminaireFloodlight for Ordinary Locations

Applications• Powerful,efficientweatherprooflightingforapplications

suchas:—Securitylighting—Productionfacilities—Warehouses—Processingplants—Storageareas—Parkinggaragesandlots

Features• Threelumenoutputsprovideupto19,500lumens.

Nominal Lumens

Wattage (W)

Efficacy (lpw)

HID Equivalent

Model Number

9,500 70 136 175W-250W IAMLGL615,000 110 136 250W-400W IAMLGL719,500 150 130 400W-750W IAMLGL8

Nominal lumen value for 5000K, detailed lumen information provided in tables.

• Choiceofopticsforoptimallightdistributioninavarietyofapplications.

• Separatefieldwiringcompartmentwithscrewterminalblockforeasyandsecureconnection(canacceptUL/CSA26-10AWG).

• Two¾”NPTentriesprovided.• Yokebracketisdesignedtoaccommodatetraditional

Areamasterbracketsandslipfittersforeasyretrofit.• Choiceofcolortemperature(CCT);5000Kcoolwhiteor3000K

warmwhite.• Ruggedandcompacthousingwithsuperiorthermaldesign

translatestolongluminairelife.• Heavyduty,hightemperaturesiliconerubbergaskets.• Thermalshockandimpactresistantclearorfrostedglasslens.• Standard6KVsurgeprotection.• Captivefastenerssecureonepiecelens.• FieldreplaceableLEDdriverandlenscover.• AmbientTemperaturerangesfrom:

—IAMLGL6,IAMLGL7andIAMLGL8from-40°Cto+65°C(-40°Fto+149°F)

Options• Improvedsafetycabledesignwithmultipleretentionpoints,

purchaseseparately• Guardandvisoravailable,purchaseseparately• Slip-fittersandmountingbracketsavailableforeasypoleor

wallmounting• 10KVSurgeProtection

Floodlight

Standard Materials• Housingandlensdoor:copperfree(4/10of1%max.)aluminum• Gaskets:siliconerubber• Yoke:zincplatedHRsteel• Bolts:stainlesssteel• Closeupplugs:(1)aluminumprovided• Guardandsafetycable:stainlesssteel• Visor:Aluminum

Standard Finishes• Housing,lenscover,visorandyokemount:architecturalbronze

polyester

Related Products• RoundTaperedSteelPoles• HingedSteelPoled• SquareTaperedSteelPoles• SquareSteelPoles• FloodlightMountingBrackets

NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X IP66/67

LED/

FLoo

DLig

hts:

NEC

/CEC

orD

iNar

y Lo

Catio

N

Visit our website at www.emerson.com or contact us at (800) 621-1506. © June 2017

232

Page 2: Industrial Areamaster Generation 2 LED Luminaire ... · PDF fileCrossarm Mounting Bracket (G-AM-8-CA) used with Pipe or Wall Mount Bracket (G-AM-8-WB). ... For Dark Sky Friendly design.

Industrial Areamaster™ Generation 2 LED LuminaireFloodlight for Ordinary Locations

NEC/CEC Certifications and Compliances• ULStandards:

—UL1598,Luminaires—UL1598A,LuminairesforInstallationonMarineVessels

• CSAStandards:—CSAC22.2No.250.0,Luminaires

• cCSAus:164460,CertificateNumber:70073607

DesignLights™ Consortium (for the following models)• Allmodelspending.

Orderusingcatalognumberingguidesbeloworselectcatalognumberfromtablesonfollowingpages.

IAMLG L7 C G 7 BU S

Series:IAMLG:Areamaster2LEDSeries

ColorTempCCT:C-5000K

W-3000K

6=7x7(non-optic)7=7X6

F-FusingS-10KVSurgeProtection

LumenLevel:L6-9KL7-15KL8-19K

Diffusion:G-ClearGlassF-FrostedGlass

Voltage:BU=120V-277Vac50/60Hz,170-300VdcBH=347-480Vac50/60Hz

Lumen Output Tables :

Lumen Output for Clear Glass Lens

IAMLGL6 IAMLGL7 IAMLGL8

NEMA7x7(NonOptic),5000KCCT,CRI70 9,900 15,300 19,900

NEMA7x6,3000KCCT,CRI80 8,100 11,900 15,500

NEMA7x6,5000KCCT,CRI70 9,000 14,200 18,400

Lumen Output for Frosted Glass Lens

IAMLGL6 IAMLGL7 IAMLGL8

NEMA7x7(NonOptic),5000KCCT 8,000 12,600 16,300

3000K CCT (warm) is not available with NEMA 7x7 light pattern Frosted Glass is only available with NEMA 7x7 light pattern Use of fuse voids Marine rating. All lumen values are typical (tolerance +/-10%).

NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X IP66/67

LED/FLooDLights: NEC/CEC orDiNary LoCatioN

Visit our website at www.emerson.com or contact us at (800) 621-1506. © June 2017

233

Page 3: Industrial Areamaster Generation 2 LED Luminaire ... · PDF fileCrossarm Mounting Bracket (G-AM-8-CA) used with Pipe or Wall Mount Bracket (G-AM-8-WB). ... For Dark Sky Friendly design.

Industrial Areamaster™ Generation 2 LED LuminaireFloodlight for Ordinary Locations

Electrical Ratings

Model Number Voltage Suffix Voltage (V) Input Power (Watts)Input Current

(Amps) Power Factor (PF)Total Harmonic Distortion (THD)

IAMLGL6

BU

120Vac 73 0.62>.9 <20%

277Vac 71 0.27

170Vdc 69 0.41N/A N/A

300Vdc 68 0.23

BH347Vac 71 0.21

>.9 <20%480Vac 71 0.16

IAMLGL7

BU

120Vac 111 0.94>.9 <20%

277Vac 106 0.43

170Vdc 113 0.67N/A N/A

300Vdc 111 0.37

BH347Vac 115 0.33

>.9 <20%480Vac 115 0.25

IAMLGL8

BU

120Vac 154 1.30>.9 <20%

277Vac 146 0.56

170Vdc 156 0.92N/A N/A

300Vdc 152 0.51

BH347Vac 150 0.43

>.9 <20%480Vac 149 0.32

Surge Protection: Integral 6KV surge protection. Option for up to 10KV surge protection. (cCSAus only). All ratings are typical.

Luminaire Category ImageFrontal Projected Area

(FPA) ft2

Drag Coefficient(DC)

Effective Projected Area (EPA) = FPA*DC ft2

90°toGround-WorstCaseMounting

1.52 1.20 1.82

45°toGround-StandardMounting 1.07 1.2 1.28

Wind Direction

Wind Direction

NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X IP66/67

LED/

FLoo

DLig

hts:

NEC

/CEC

orD

iNar

y Lo

Catio

N

Visit our website at www.emerson.com or contact us at (800) 621-1506. © June 2017

234

Page 4: Industrial Areamaster Generation 2 LED Luminaire ... · PDF fileCrossarm Mounting Bracket (G-AM-8-CA) used with Pipe or Wall Mount Bracket (G-AM-8-WB). ... For Dark Sky Friendly design.

Industrial Areamaster™ Generation 2 LED LuminaireFloodlight for Ordinary Locations

NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X IP66/67

CCTLumen Output Wattage

Efficacy (lm/W)

Optical Pattern

Catalog Number

Clear Glass

120-277 Vac/170-300 Vdc

5000K(coolwhite) 9900 70 141 NEMA7x7(150°x150°) IAMLGL6CG6BU

5000K(coolwhite) 9000 70 129 NEMA7x6(136°x113°) IAMLGL6CG7BU

3000K(warmwhite) 8100 70 116 NEMA7x6(136°x113°) IAMLGL6WG7BU

5000K(coolwhite) 15300 111 138 NEMA7x7(150°x150°) IAMLGL7CG6BU

5000K(coolwhite) 14200 111 128 NEMA7x6(136°x113°) IAMLGL7CG7BU

3000K(warmwhite) 11900 111 107 NEMA7x6(136°x113°) IAMLGL7WG7BU

5000K(coolwhite) 19900 158 126 NEMA7x7(150°x150°) IAMLGL8CG6BU

5000K(coolwhite) 18400 158 116 NEMA7x6(136°x113°) IAMLGL8CG7BU

3000K(warmwhite) 15500 158 98 NEMA7x6(136°x113°) IAMLGL8WG7BU

347-480 Vac

5000K(coolwhite) 9900 71 139 NEMA7x7(150°x150°) IAMLGL6CG6BH

5000K(coolwhite) 9000 71 127 NEMA7x6(136°x113°) IAMLGL6CG7BH

3000K(warmwhite) 8100 71 114 NEMA7x6(136°x113°) IAMLGL6WG7BH

5000K(coolwhite) 15300 115 133 NEMA7x7(150°x150°) IAMLGL7CG6BH

5000K(coolwhite) 14200 115 123 NEMA7x6(136°x113°) IAMLGL7CG7BH

3000K(warmwhite) 11900 109 109 NEMA7x6(136°x113°) IAMLGL7WG7BH

5000K(coolwhite) 19900 157 127 NEMA7x7(150°x150°) IAMLGL8CG6BH

5000K(coolwhite) 18400 157 117 NEMA7x6(136°x113°) IAMLGL8CG7BH

3000K(warmwhite) 15500 150 103 NEMA7x6(136°x113°) IAMLGL8WG7BH

Frosted Glass

120-277 Vac/170-300 Vdc

5000K(coolwhite) 8100 70 116 NEMA7x7(150°x150°) IAMLGL6CF6BU

5000K(coolwhite) 12700 111 114 NEMA7x7(150°x150°) IAMLGL7CF6BU

5000K(coolwhite) 16500 158 104 NEMA7x7(150°x150°) IAMLGL8CF6BU

347-480 Vac

5000K(coolwhite) 8100 71 114 NEMA7x7(150°x150°) IAMLGL6CF6BH

5000K(coolwhite) 12700 115 110 NEMA7x7(150°x150°) IAMLGL7CF6BH

5000K(coolwhite) 16500 157 105 NEMA7x7(150x150) IAMLGL8CF6BH

For Fusing option, add suffix F to end of part number, example AMLGL8CG6BUF. For 10KV surge protection, add suffix S to end of part number, example AMLGL7CG7BUS. For both Fusing and 10KV surge, add suffix FS to end of part number, example AMLGL8CG7BUFS.

LED/FLooDLights: NEC/CEC orDiNary LoCatioN

Visit our website at www.emerson.com or contact us at (800) 621-1506. © June 2017

235

Page 5: Industrial Areamaster Generation 2 LED Luminaire ... · PDF fileCrossarm Mounting Bracket (G-AM-8-CA) used with Pipe or Wall Mount Bracket (G-AM-8-WB). ... For Dark Sky Friendly design.

Industrial Areamaster™ Generation 2 LED LuminaireFloodlight for Ordinary Locations

NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X IP66/67

Accessories and Replacement Parts

Description Catalog NumberCrossarm Mounting Bracket

Has180°horizontaladjustment—degreemarked.Facilitatesmountingfloodlighttocrossarmorotherflatsurface,ortoG-AM-8-WB.Includesfloodlightyokebolts.Malleableiron,zincplated,chromatesealed,architecturalbronzepolyesterfinish.

G-AM-8-CA

Pipe or Wall Mount Bracket

UsedwithG-AM-8-CA.Clampsto1”to2-1/2”pipe,verticalorhorizontal,ormountsonflatsurfaces.IncludesU-boltandcrossarmbracketbolts.Malleableiron,zincplated,chromatesealed,witharchitecturalbronzepolyesterfinish.

G-AM-8-WB

CrossarmMountingBracket(G-AM-8-CA)usedwithPipeorWallMountBracket(G-AM-8-WB).

Poletop Slip-Fitter

Slip-fits1-1/2”or2”pipesizepoletoptenons.Includesfloodlightyokebolts,3lockingbolts,andcordgrip.Bodyismalleableiron-zincplated,chromatesealed,withcastaluminumcap.Assemblyhasarchitecturalbronzepolyesterfinish.

G-SF20

Slip-fits1"or1-1/2”pipesizepoletoptenons.Includesfloodlightyokebolts,3lockingbolts,andcordgrip.Bodyismalleableiron-zincplated,chromatesealed,withcastaluminumcap.Assemblyhasarchitecturalbronzepolyesterfinish.

AMLEDSF1

Poletop Slip-Fitter

Slip-fits2”or2-1/2”poletoptenons.Includesfloodlightyokebolts,3lockingbolts,andcordgrip.Malleableiron,zincplated,chromatesealed,witharchitecturalbronzepolyesterfinish.

G-AM-8-SF

LED/

FLoo

DLig

hts:

NEC

/CEC

orD

iNar

y Lo

Catio

N

Visit our website at www.emerson.com or contact us at (800) 621-1506. © June 2017

236

Page 6: Industrial Areamaster Generation 2 LED Luminaire ... · PDF fileCrossarm Mounting Bracket (G-AM-8-CA) used with Pipe or Wall Mount Bracket (G-AM-8-WB). ... For Dark Sky Friendly design.

Industrial Areamaster™ Generation 2 LED LuminaireFloodlight for Ordinary Locations

NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X IP66/67

Accessories and Replacement Parts

Description Catalog Number

Wall Mount Bracket

UsedwithG-AM-8-SFandGSF-20toprovideawallmountingoption.GalvanizedSteel. GPSWB6GAL

Wire Guard

Stainlesssteel. LGGUARD

Safety Cable

Stainlesssteel. LEDSC

Visor

Steelwitharchitecturalbronzepolyesterfinish.ForDarkSkyFriendlydesign. AMLGV

Portable Floodlight Base

Portablefloodlightbasefortemporarylightingapplications.Tobeusedwithwireguard.Malleableironwitharchitecturalbronzepolyesterfinish.

G-AM-PFB

LED/FLooDLights: NEC/CEC orDiNary LoCatioN

Visit our website at www.emerson.com or contact us at (800) 621-1506. © June 2017

237

Page 7: Industrial Areamaster Generation 2 LED Luminaire ... · PDF fileCrossarm Mounting Bracket (G-AM-8-CA) used with Pipe or Wall Mount Bracket (G-AM-8-WB). ... For Dark Sky Friendly design.

Industrial Areamaster™ Generation 2 LED LuminaireFloodlight for Ordinary Locations

NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X IP66/67

Replacement Covers

AMLGCLEAR

AMLGFROST

VoltageDriver

WattageConstant

Current Setting Luminaire Model CCT Catalog Number

Replacement Drivers

BU100watt 410mA IAMLGL6C,

IAMLGL6W 5Kand3KAPMS100C105UD41

BH APMS100C105HD41

BU150watt 650mA IAMLGL7W 3K

APMS150C105UD65

BH APMS150C105HD65

BU150watt 680mA IAMLGL7C 5k

APMS150C105UD68

BH APMS150C105HD68

BU150watt 890mA IAMLGL8W 3K

APMS150C105UD89

BH APMS150C105HD89

BU150watt 930mA IAMLGL8C 5k

APMS150C105UD93

BH APMS150C105HD93

Industrial Areamaster Generation 2 Accessory Weights

Description Weight in kg (lbs)

IAMLGL6,IAMLGL7,IAMLGL8Luminaires 9.8(21.6)

YokeBracket 1.41(3.1)

Visor 0.2(0.4)

Guard 0.2(0.4)

SafetyCable 0.2(0.4)

CrossarmMountingBracketG-AM-8-CA 1.4(3.1)

PipeorWallMountBracketG-AM-8-WB 2.9(6.4)

PoletopSlip-FitterGSF20 1.4(3.1)

PoletopSlip-FitterAMLEDSF1 2.4(5.3)

PoletopSlip-FitterGAM8SF -

- -

LED/

FLoo

DLig

hts:

NEC

/CEC

orD

iNar

y Lo

Catio

N

Visit our website at www.emerson.com or contact us at (800) 621-1506. © June 2017

238

Page 8: Industrial Areamaster Generation 2 LED Luminaire ... · PDF fileCrossarm Mounting Bracket (G-AM-8-CA) used with Pipe or Wall Mount Bracket (G-AM-8-WB). ... For Dark Sky Friendly design.

Dimensions in Millimeters (Inches)

Floodlight

(4)YOKEBOLTS

CONDUITENTRY

(3)MOUNTINGHOLESØ14mm(0.56in)

328.7mm

(12.94in)

413.5mm

(16.28in)

44.5mm

(1.75in)

88.9mm

(3.5in)

57.2mm

(2.25in)

351.5mm

(13.84in)

128.3mm

(5.05in)

152.4mm

(6.00in)

152.4mm(6.00in)TURNINGRADIUS180°ROTATION

156.5mm

(6.16in)SqUARE

YOKE

(2)HUBSFOR3/4”NPTCONDUIT

(4)1/4-20UNC-2BTHREAD

Industrial Areamaster™ Generation 2 LED LuminaireFloodlight for Ordinary Locations

NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X IP66/67

LED/FLooDLights: NEC/CEC orDiNary LoCatioN

Visit our website at www.emerson.com or contact us at (800) 621-1506. © June 2017

239

Page 9: Industrial Areamaster Generation 2 LED Luminaire ... · PDF fileCrossarm Mounting Bracket (G-AM-8-CA) used with Pipe or Wall Mount Bracket (G-AM-8-WB). ... For Dark Sky Friendly design.

Photometric Data — DATA SHOWN IS ABSOLUTENEMA 7x7, Clear GlassREPORT NUMBER: IAMLGL6CG6BULuminaire Lumens 9,964

POLAr CANDELA DISTrIBUTION ISOFOOT CANDLE PLOT AT 45° FLOOD SUMMAry

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

2,833

3,400

2,267

1,700

567

1,133

1,700

2,267

2,833

3,400

567

1,133

0

50°

40°30°20°10°0°

-0° H -22.5° H-45° H-67.5° H

-90° H

3

2

23 1 0

1

0

1

2

3

4

20 fc

5 fc 0.2 fc2.5 fc

Point of Max FC: 10.020.1 fc

1fc10 fc 0.5 fc

1 2 3 4 Efficiency LumensHorizontal

Spread Vertical SpreadField(10%) 98.5% 9,817.4 150 148Beam(50%) 82.2% 8,196.6 117.3 116.2

Total 100% 9,964.0

NEMA 7x7, Frosted GlassREPORT NUMBER: IAMLGL6CF6BULuminaire Lumens 8,115

POLAr CANDELA DISTrIBUTION ISOFOOT CANDLE PLOT AT 45° FLOOD SUMMAry

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

2,583

3,100

2,067

1,550

517

1,033

1,550

2,067

2,583

3,100

517

1,033

0

50°

40°30°20°10°0°

-0° H -22.5° H-45° H-67.5° H

-90° H

3

2

23 1 0

1

0

1

2

3

4

20 fc

5 fc 0.2 fc2 fc 0.1 fc

1fc10 fc 0.5 fc

1 2 3 4

Efficiency LumensHorizontal

SpreadVertical Spread

Field(10%) 98.1% 7,961.7 155.3 151.5Beam(50%) 71.5% 5,804.1 105.8 105.5

Total 100% 8,112.2

Industrial Areamaster™ Generation 2 LED LuminaireFloodlight for Ordinary Locations

Tilt Angle- 45 Degree LLF-0.9

Mounting Height Side-to-Side Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 66 50 38 1630 78 50 28 N/A40 70 40 N/A N/A

Tilt Angle- 45 Degree LLF-0.9

Mounting Height

Maximum Point Forward Throw Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 1.51 45 35 24 1130 0.68 47 36 21 N/A40 0.38 50 35 N/A N/A

Tilt Angle- 45 Degree LLF-0.9

Mounting Height Side-to-Side Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 60 44 30 430 64 34 20 N/A40 56 30 N/A N/A

Tilt Angle- 45 Degree LLF-0.9

Mounting Height

Maximum Point Forward Throw Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 2.49 42 33 24 830 1.10 45 32 15 N/A40 0.62 48 25 N/A N/A

NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X IP66/67

LED/

FLoo

DLig

hts:

NEC

/CEC

orD

iNar

y Lo

Catio

N

Visit our website at www.emerson.com or contact us at (800) 621-1506. © June 2017

240

Page 10: Industrial Areamaster Generation 2 LED Luminaire ... · PDF fileCrossarm Mounting Bracket (G-AM-8-CA) used with Pipe or Wall Mount Bracket (G-AM-8-WB). ... For Dark Sky Friendly design.

Tilt Angle- 45 Degree LLF-0.9

Mounting Height

Maximum Point Forward Throw Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 4.42 50 39 29 1630 1.97 55 43 25 N/A40 1.11 57 40 19 N/A

Industrial Areamaster™ Generation 2 LED LuminaireFloodlight for Ordinary Locations

Photometric Data — DATA SHOWN IS ABSOLUTENEMA 7x7, Clear GlassREPORT NUMBER: IAMLGL7CG6BU

Luminaire Lumens 15,320

POLAr CANDELA DISTrIBUTION ISOFOOT CANDLE PLOT AT 45° FLOOD SUMMAry

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

4,417

5,300

3,533

2,650

883

1,767

2,650

3,533

4,417

5,300

883

1,767

0

50°

40°30°20°10°0°

-0° H -22.5° H-45° H-67.5° H

-90° H

3

2

23 1 0

1

0

1

2

3

4

20 fc

5 fc 0.2 fc2.5 fc

Point of Max FC: 10.020.1 fc

1fc10 fc 0.5 fc

1 2 3 4Efficiency Lumens

Horizontal Spread

Vertical Spread

Field(10%) 98.5% 15,102.6 151.2 147Beam(50%) 81.9% 12,555.7 117 115.4

Total 100% 15,320.4

NEMA 7x7, Frosted GlassREPORT NUMBER: IAMLGL7CF6BULuminaire Lumens 12,782

POLAr CANDELA DISTrIBUTION ISOFOOT CANDLE PLOT AT 45° FLOOD SUMMAry

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

4,083

4,900

3,267

2,450

817

1,633

2,450

3,267

4,083

4,900

817

1,633

0

50°

40°30°20°10°0°

-0° H -22.5° H-45° H-67.5° H

-90° H

3

2

23 1 0

1

0

1

2

3

4

20 fc

5 fc 0.2 fc2 fc 0.1 fc

1fc10 fc 0.5 fc

1 2 3 4

Efficiency LumensHorizontal

SpreadVertical Spread

Field(10%) 98.1% 12,536.1 155.4 150.7Beam(50%) 71.3% 9,112.8 105.4 105.6

Total 100% 12,777.9

NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X IP66/67

Tilt Angle- 45 Degree LLF-0.9

Mounting Height Side-to-Side Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 80 60 48 2230 88 68 42 N/A40 94 60 24 N/A

Tilt Angle- 45 Degree LLF-0.9

Mounting Height

Maximum Point Forward Throw Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 2.36 54 41 26 1930 1.05 60 45 30 N/A40 0.59 60 42 31 N/A

Tilt Angle- 45 Degree LLF-0.9

Mounting Height Side-to-Side Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 70 56 40 2030 80 58 38 N/A40 80 50 16 N/A

LED/FLooDLights: NEC/CEC orDiNary LoCatioN

Visit our website at www.emerson.com or contact us at (800) 621-1506. © June 2017

241

Page 11: Industrial Areamaster Generation 2 LED Luminaire ... · PDF fileCrossarm Mounting Bracket (G-AM-8-CA) used with Pipe or Wall Mount Bracket (G-AM-8-WB). ... For Dark Sky Friendly design.

Industrial Areamaster™ Generation 2 LED LuminaireFloodlight for Ordinary Locations

Photometric Data — DATA SHOWN IS ABSOLUTENEMA 7x7, Clear GlassREPORT NUMBER: IAMLGL8CG6BU

Luminaire Lumens 19,895

POLAr CANDELA DISTrIBUTION ISOFOOT CANDLE PLOT AT 45° FLOOD SUMMAry

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

5,750

6,900

4,600

3,450

1,150

2,300

3,450

4,600

5,750

6,900

1,150

2,300

0

50°

40°30°20°10°0°

-0° H -22.5° H-45° H-67.5° H

-90° H

5

4

34 2 1

3

2

1

0

1

2

3

4

5

20 fc

5 fc 0.2 fc2.5 fc

Point of Max FC: 10.020.1 fc

1fc10 fc 0.5 fc

0 1 2 3 54

Efficiency LumensHorizontal

Spread Vertical SpreadField(10%) 98.6% 19,614.8 151 146.8Beam(50%) 81.7% 16,267.6 116.7 115.2

Total 100% 19,895.4

NEMA 7x7, Frosted GlassREPORT NUMBER: IAMLGL8CF6BULuminaire Lumens 16,503

POLAr CANDELA DISTrIBUTION ISOFOOT CANDLE PLOT AT 45° FLOOD SUMMAry

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

5,333

6,400

4,267

3,200

1,067

2,133

3,200

4,267

5,333

6,400

1,067

2,133

0

50°

40°30°20°10°0°

-0° H -22.5° H-45° H-67.5° H

-90° H

3

2

23 1 0

1

0

1

2

3

4

20 fc

5 fc 0.2 fc2 fc 0.1 fc

1fc10 fc 0.5 fc

1 2 3 4

Efficiency LumensHorizontal

SpreadVertical Spread

Field(10%) 98.1% 16,189.8 155.3 150.7Beam(50%) 71.3% 11,766.7 105.2 105.5

Total 100% 16,498.6

Tilt Angle- 45 Degree LLF-0.9

Mounting Height Side-to-Side Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 84 70 52 3230 96 72 54 1540 104 72 48 N/A

Tilt Angle- 45 Degree LLF-0.9

Mounting Height

Maximum Point Forward Throw Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 2.91 59 45 35 2230 1.29 63 51 33 1240 0.73 70 50 30 N/A

NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X IP66/67

Tilt Angle- 45 Degree LLF-0.9

Mounting Height Side-to-Side Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 78 60 44 2230 88 62 34 N/A40 98 58 38 N/A

Tilt Angle- 45 Degree LLF-0.9

Mounting Height

Maximum Point Forward Throw Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 5.76 55 43 32 2030 2.56 31 45 31 N/A40 1.43 62 49 29 N/A

LED/

FLoo

DLig

hts:

NEC

/CEC

orD

iNar

y Lo

Catio

N

Visit our website at www.emerson.com or contact us at (800) 621-1506. © June 2017

242

Page 12: Industrial Areamaster Generation 2 LED Luminaire ... · PDF fileCrossarm Mounting Bracket (G-AM-8-CA) used with Pipe or Wall Mount Bracket (G-AM-8-WB). ... For Dark Sky Friendly design.

Industrial Areamaster™ Generation 2 LED LuminaireFloodlight for Ordinary Locations

Photometric Data — DATA SHOWN IS ABSOLUTENEMA 7x6, Clear GlassREPORT NUMBER: IAMLGL6CG7BU

Luminaire Lumens 9,086

POLAr CANDELA DISTrIBUTION ISOFOOT CANDLE PLOT AT 45° FLOOD SUMMAry

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

4,583

5,500

3,667

2,750

917

1,833

2,750

3,667

4,583

5,500

917

1,833

0

50°

40°30°20°10°0°

-0° H -22.5° H-45° H-67.5° H

-90° H

2

23 1 0

1

0

1

2

3

20 fc

5 fc 0.2 fc2 fc

Point of Max FC: 10.020.1 fc

1fc10 fc 0.5 fc

1 2 3Efficiency Lumens

Horizontal Spread Vertical Spread

Field(10%) 96.2% 8,738.1 134.9 112.1Beam(50%) 62% 5,631.5 120.5 45.2

Total 100% 9,086.2

NEMA 7x6, Clear GlassREPORT NUMBER: IAMLGL6WG7BU

Luminaire Lumens 8,111

POLAr CANDELA DISTrIBUTION ISOFOOT CANDLE PLOT AT 45° FLOOD SUMMAry

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

4,167

5,000

3,333

2,500

833

1,667

2,500

3,333

4,167

5,000

833

1,667

0

50°

40°30°20°10°0°

-0° H -22.5° H-45° H-67.5° H

-90° H

2

23 1 0

1

0

1

2

3

20 fc

5 fc 0.2 fc2 fc

Point of Max FC: 10.020.1 fc

1fc10 fc 0.5 fc

1 2 3

Efficiency LumensHorizontal

SpreadVertical Spread

Field(10%) 96.1% 7,798.3 135.3 112Beam(50%) 61.5% 4,987.0 119.9 45

Total 100% 8,111.0

Tilt Angle- 45 Degree LLF-0.9

Mounting Height Side-to-Side Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 84 64 44 1630 90 66 36 N/A40 96 56 N/A N/A

Tilt Angle- 45 Degree LLF-0.9

Mounting Height

Maximum Point Forward Throw Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 3.18 44 36 30 1630 1.41 52.5 42 27 N/A40 0.807 56 40 N/A N/A

Tilt Angle- 45 Degree LLF-0.9

Mounting Height Side-to-Side Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 80 64 44 1630 84 60 36 N/A40 88 48 N/A N/A

Tilt Angle- 45 Degree LLF-0.9

Mounting Height

Maximum Point Forward Throw Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 2.92 42 36 28 1530 1.3 52.5 42 24 N/A40 0.73 56 36 N/A N/A

NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X IP66/67

LED/FLooDLights: NEC/CEC orDiNary LoCatioN

Visit our website at www.emerson.com or contact us at (800) 621-1506. © June 2017

243

Page 13: Industrial Areamaster Generation 2 LED Luminaire ... · PDF fileCrossarm Mounting Bracket (G-AM-8-CA) used with Pipe or Wall Mount Bracket (G-AM-8-WB). ... For Dark Sky Friendly design.

Industrial Areamaster™ Generation 2 LED LuminaireFloodlight for Ordinary Locations

Photometric Data — DATA SHOWN IS ABSOLUTENEMA 7x6, Clear GlassREPORT NUMBER: IAMLGL7CG7BU

Luminaire Lumens 14,205

POLAr CANDELA DISTrIBUTION ISOFOOT CANDLE PLOT AT 45° FLOOD SUMMAry

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

7,000

8,400

5,600

4,200

1,400

2,800

4,200

5,600

7,000

8,400

1,400

2,800

0

50°

40°30°20°10°0°

-0° H -22.5° H-45° H-67.5° H

-90° H

3

2

23 1 0

1

0

1

2

3

4

20 fc

5 fc 0.2 fc2 fc 0.1 fc

1fc10 fc 0.5 fc

1 2 3 4

Efficiency LumensHorizontal

Spread Vertical SpreadField(10%) 96.3% 13,678.5 135.3 112.5Beam(50%) 62.6% 8,887.6 120.7 45.7

Total 100% 14,205.3

NEMA 7x6, Clear GlassREPORT NUMBER: IAMLGL7WG7BU

Luminaire Lumens 11,971

POLAr CANDELA DISTrIBUTION ISOFOOT CANDLE PLOT AT 45° FLOOD SUMMAry

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

6,083

7,300

4,867

3,650

1,217

2,433

3,650

4,867

6,083

7,300

1,217

2,433

0

50°

40°30°20°10°0°

-0° H -22.5° H-45° H-67.5° H

-90° H

2

23 1 0

1

0

1

2

3

20 fc

5 fc 0.2 fc2 fc

Point of Max FC: 10.020.1 fc

1fc10 fc 0.5 fc

1 2 3

Efficiency LumensHorizontal

SpreadVertical Spread

Field(10%) 96.1% 11,503.9 135.2 112Beam(50%) 62% 7,424.4 119.8 45.2

Total 100% 11,971.9

Tilt Angle- 45 Degree LLF-0.9

Mounting Height Side-to-Side Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 96 80 60 3630 108 90 54 N/A40 120 80 32 N/A

Tilt Angle- 45 Degree LLF-0.9

Mounting Height

Maximum Point Forward Throw Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 4.91 48 40 35 2430 2.22 60 45 37.5 n/a40 1.25 64 52 24 N/A

Tilt Angle- 45 Degree LLF-0.9

Mounting Height Side-to-Side Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 90 72 52 3030 108 78 48 N/A40 112 72 N/A N/A

Tilt Angle- 45 Degree LLF-0.9

Mounting Height

Maximum Point Forward Throw Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 4.3 46 40 32 2030 1.91 57 45 33 N/A40 1.07 64 50 N/A N/A

NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X IP66/67

LED/

FLoo

DLig

hts:

NEC

/CEC

orD

iNar

y Lo

Catio

N

Visit our website at www.emerson.com or contact us at (800) 621-1506. © June 2017

244

Page 14: Industrial Areamaster Generation 2 LED Luminaire ... · PDF fileCrossarm Mounting Bracket (G-AM-8-CA) used with Pipe or Wall Mount Bracket (G-AM-8-WB). ... For Dark Sky Friendly design.

Industrial Areamaster™ Generation 2 LED LuminaireFloodlight for Ordinary Locations

Photometric Data — DATA SHOWN IS ABSOLUTENEMA 7x6, Clear GlassREPORT NUMBER: IAMLGL8CG7BU

Luminaire Lumens 18,467

POLAr CANDELA DISTrIBUTION ISOFOOT CANDLE PLOT AT 45° FLOOD SUMMAry

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

10,000

12,000

8,000

6,000

2,000

4,000

6,000

8,000

10,000

12,000

2,000

4,000

0

50°

40°30°20°10°0°

-0° H -22.5° H-45° H-67.5° H

-90° H

3

2

23 1 0

1

0

1

2

3

4

20 fc

5 fc 0.2 fc2 fc

Point of Max FC: 10.020.1 fc

1fc10 fc 0.5 fc

1 2 3 4 Efficiency LumensHorizontal

Spread Vertical SpreadField(10%) 96.2% 17,761.1 135.1 112.2Beam(50%) 62.5% 11,537.1 120.5 45.3

Total 100% 18,467.4

NEMA 7x6, Clear GlassREPORT NUMBER: IAMLGL8WG7BU

Luminaire Lumens 15,556

POLAr CANDELA DISTrIBUTION ISOFOOT CANDLE PLOT AT 45° FLOOD SUMMAry

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

7,917

9,500

6,333

4,750

1,583

3,167

4,750

6,333

7,917

9,500

1,583

3,167

0

50°

40°30°20°10°0°

-0° H -22.5° H-45° H-67.5° H

-90° H

3

2

23 1 0

1

0

1

2

3

4

20 fc

5 fc 0.2 fc2 fc 0.1 fc

1fc10 fc 0.5 fc

1 2 3 4 Efficiency LumensHorizontal

SpreadVertical Spread

Field(10%) 96.1% 14,945.7 135 111.8Beam(50%) 62% 9,641.5 119.5 45

Total 100% 15,555.8

Tilt Angle- 45 Degree LLF-0.9

Mounting Height Side-to-Side Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 100 80 64 3630 117 90 60 N/A40 120 80 40 N/A

Tilt Angle- 45 Degree LLF-0.9

Mounting Height Side-to-Side Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 104 84 68 4030 120 102 66 1240 128 96 48 N/A

Tilt Angle- 45 Degree LLF-0.9

Mounting Height

Maximum Point Forward Throw Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 5.61 50 42 36 2630 2.5 60 52.5 37.5 N/A40 1.4 70 56 36 N/A

Tilt Angle- 45 Degree LLF-0.9

Mounting Height

Maximum Point Forward Throw Distance (ft)

0.5Fc 1Fc 2Fc 5Fc20 6.44 52 44 36 2630 2.86 63 54 39 2140 1.63 72 60 40 N/A

NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X IP66/67

LED/FLooDLights: NEC/CEC orDiNary LoCatioN

Visit our website at www.emerson.com or contact us at (800) 621-1506. © June 2017

245