INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of...

32
INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 [email protected]

Transcript of INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of...

Page 1: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

INDOT Detection Test Facility

Jim Sturdevant, P.E.Operations SupportIndiana Department of TransportationIndianapolis, IN

317 232 [email protected]

Page 2: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Outline

ObjectivesBackground on West Lafayette SiteNew Site in NoblesvilleUpcoming Testing in 2004

Page 3: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Objectives

Develop an objective performance specification and evaluation procedures for the INDOT approved products list. Video Count Detectors Other emerging technologies

Provide a facility for quantitatively evaluating new control features.

Page 4: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

West Lafayette Site

West Lafayette, IN Stadium & US 231

Page 5: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Data Collection

West Lafayette, IN Urban Currently operational, to be

reconfigured similar to Noblesville in 2004

Noblesville, IN (Under construction) Suburban Reconstruction Summer 2003.

Page 6: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Dual Cabinets

Page 7: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Signal Cabinet

Page 8: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Instrumentation Cabinet

Fiber Connection

Video Modems

IP Based I/O Monitoring

Page 9: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Stadium & Northwestern Fiber Optic Cable

Connection

Page 10: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Indoor Facility

Page 11: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Indoor End of Equipment

Page 12: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Indoor Interface: Signal Status & Cabinet

Page 13: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Text Overlay

• Phase Indication

• ILD Status

• VID1 Status

• VID2 Status

NA,NB NL

Page 14: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Noblesville Data Collection Site

Piggybacking on new INDOT reconstruction of SR 37 an SR 38 that will be used as INDOT test siteBuild upon success of West Lafayette instrumented intersection, and improve on some of those limitationsPavement Mill and Fill2 CabinetsDSL ServiceRemote IP PTZ Camera60 Detection Channels on 4 BIUs in Signal Cabinet

77 inductive loops 34 microloops

Additional 12 Autoscope video detection units (3 per approach)

Additional video units by other vendors60’ Mast Arms (Cameras at ~60, 36, and Pole)

Page 15: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Sensors

Micro LoopsPeek Video DetectionAutoscope Video DetectionIteris Video DetectionPreformed Loops

Page 16: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Site Location

Page 17: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Noblesville Plan View: Detection/Phasing

N

Page 18: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Noblesville Plan View: Example Video Detection

N

Page 19: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Example Noblesville Camera Views: Note: new installation will have improved orientation/aspect/height

a) Northbound

b) Southbound

c) Eastbound

d) Westbound

Page 20: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

SE Corner, Existing Cabinet

Page 21: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Noblesville Data Acquisition

Use TS 2 Type 1 CabinetBut will use 24 Volt signals interfaced to a Solo ProSolo Pro will collect time stamped state changes on up to 8 digital inputs and display status on video

Page 22: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Example Solo Pro

Long detection zoneShort detection zonesFor Northbound (2) inputs of Phase 2

& 5 Green Status (4) inputs for

detectors (2 spare)

Page 23: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

MiniHub Data Collection

8 Discrete InputsSimilar capabilities (logging/video overlay) as West Lafayette site, but with equipment familiar to techs

Page 24: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Supplemental Data Collection

Will also use Opto 22 data acquisition

Allow synchronized data collection time stamps for 128 I/O points

Ethernet Access Ftp transfer of time

stamped logs Embed simple logic

for preprocessing data

Page 25: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Example Solo Pro Data

Page 26: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Data Collection

Solo Pro will be use for data collection purposes since it provides a convenient way to log time stamped events (video overlay an file) using equipment INDOT technicians/engineers are familiar with.However, other loop and video detection units will be installed….outputs from those units will be connected to spare (6) Solo Pro Inputs

Page 27: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Auxilary Cabinet Patch Panels

Page 28: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Northbound Detector Output Patch Panel

NL-M1

NL-M2

NL12

NL12C

NL34C

GND

GND

GND

NA-M1

NA-M2

NA12

NA12C

NA34C

NA6

NA-M7

NA8

NB-M1

NB-M2

NB12

NB12C

NB34C

NB6

NB-M7

NB8

NA34 NB34NL34

NB-M5NA-M5

NC-M1

NC-M2

NC12

NC12C

NC34

NC34C

NC-M5

NC6

NC-M7

NC8

Northbound Solo Input Patch Panel

B3B2B1

1

2

3

4

5

6

7

8

Phase 2 Overlap APhase 5

Cam2

Cam3

Cam1

Page 29: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Northbound Solo Output Patch Panel

LED Camera 1 Camera 2 Camera 3

Cabinet 1 BIU4 Patch Panel

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

B3 B3 B3B2 B2 B2B1 B1 B1Cam

1Cam

2Cam

3

1

2

3

4

5

6

7

8

10

9

11

12

13

14

15

16

Page 30: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Example Solo Pro Video

Page 31: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Upcoming Testing

Quantifying loop and video detection accuracy False Calls Missed Calls

Quantifying loop and video counting accuracyEvaluating new algorithms

Page 32: INDOT Detection Test Facility Jim Sturdevant, P.E. Operations Support Indiana Department of Transportation Indianapolis, IN 317 232 5073 JSTURDEVANT@indot.state.in.us.

Questions?