IDU and Accessories Order Codes Reference

download IDU and Accessories Order Codes Reference

of 22

description

ff

Transcript of IDU and Accessories Order Codes Reference

  • FlexiHybrid

    IDU and Accessories Order Codes Reference

    A25000-A0300-F060-02-76P1

    Issue: 2 Issue date: February 2010

  • 2 A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    IDU and Accessories Order Codes Reference

    The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.

    The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.

    Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMEN-TATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.

    This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.

    The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

    Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.

    Copyright Nokia Siemens Networks 2010. All rights reserved.

    f Important Notice on Product SafetyElevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts may also have elevated operating temperatures.

    Non-observance of these conditions and the safety instructions can result in personal injury or in property damage.

    Therefore, only trained and qualified personnel may install and maintain the system.

    The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to comply with the applicable safety standards.

    The same text in German:

    Wichtiger Hinweis zur Produktsicherheit

    In elektrischen Anlagen stehen zwangslufig bestimmte Teile der Gerte unter Span-nung. Einige Teile knnen auch eine hohe Betriebstemperatur aufweisen.

    Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Krperverlet-zungen und Sachschden fhren.

    Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und wartet.

    Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Gerte mssen die zutreffenden Sicherheitsbestimmungen erfllen.

  • A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    3

    IDU and Accessories Order Codes Reference

    Table of ContentsThis document has 22 pages.

    1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.1 Intended audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.2 Structure of this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.3 Symbols and conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.4 History of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91.5 Waste electrical and electronic equipment (WEEE) . . . . . . . . . . . . . . . . 91.6 RoHS compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

    2 Indoor assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112.1 Licence fees. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.2 Licence fee upgrading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.3 List of spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    3 Patch panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143.1 Patch panels P/Ns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143.2 Patch panel composition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143.3 Patch Panel equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    4 Accessories and installation kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    5 IDU-ODU braided coaxial cables and accessories . . . . . . . . . . . . . . . . 205.1 Cable supply until December 31, 2009 . . . . . . . . . . . . . . . . . . . . . . . . . 205.2 Cable supply from January 1, 2010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

    6 Racks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

  • 4 A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    IDU and Accessories Order Codes Reference

    List of FiguresFigure 1 WEEE label. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Figure 2 IDU slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

  • A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    5

    IDU and Accessories Order Codes Reference

    List of TablesTable 1 Structure of this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Table 2 List of conventions used in this document . . . . . . . . . . . . . . . . . . . . . . . 7Table 3 History of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Table 4 FlexiHybrid IDU Compositions from SVR 2.1 . . . . . . . . . . . . . . . . . . . . 11Table 5 Licence fees . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Table 6 List of spare parts - IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Table 7 Patch Panels P/Ns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Table 8 Patch Panel equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Table 9 Braided Long IDU-ODU cable and accessories . . . . . . . . . . . . . . . . . . 16Table 10 " Long IDU-ODU cable and accessories . . . . . . . . . . . . . . . . . . . . . . 16Table 11 Connection elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Table 12 Connection elements (alternative to connection elements in the previous

    table) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Table 13 Surge Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Table 14 14xE1 cable (x-meters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Table 15 14E1 cable-RJ45 (x-meters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Table 16 Handset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Table 17 Electrical SFP 1000Base-T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Table 18 Optical SFP 1000Base-SX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Table 19 Optical SFP 1000Base-LX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Table 20 STM1-opt Cable kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Table 21 GbE optical SX Cable Xm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Table 22 GbE optical LX Cable Xm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Table 23 Set Andrew . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Table 24 Set Intercond . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Table 25 Cable set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Table 26 Racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Table 27 Fixing kit for racks ETSI (333-043/81) . . . . . . . . . . . . . . . . . . . . . . . . . 22Table 28 Fixing kit for racks ETSI for floating floors (Optional) (332-309/36) . . . 22

  • 6 A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    IDU and Accessories Order Codes Reference

  • A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    7

    IDU and Accessories Order Codes Reference Preface

    1 PrefaceThis document provides the complete ordering list of the FlexiHybrid IDU and the relevant accessories.

    1.1 Intended audienceThis document is intended to the radio network planners in charge to plan radio links with the FlexiHybrid.

    1.2 Structure of this documentThe document is divided into the following main chapters:

    1.3 Symbols and conventionsThe following symbols and conventions are used in this document:

    Chapter Title Subject

    Chapter 1 Preface Provides an introduction to the document

    Chapter 2 Indoor assembly Provides the list of the IDU and licence fee product codes

    Chapter 3 Patch panels Provides the list of the Patch panels product codes

    Chapter 4 Accessories and installation kits

    Provides the list of the accessory and installation kit product codes

    Chapter 5 IDU-ODU braided coaxial cables and accessories

    Provides the types of IDU-ODU cables to be used

    Chapter 6 Racks Provides the list of the racks

    Table 1 Structure of this document

    Representation Meaning

    Bold Text in the graphical user interface (window and wizard titles, field names, buttons, etc.) is represented in bold face.Example: Click Shutdown and then click OK to turn off the com-puter.

    Italic Field values, file names, file extensions, folder and directory names are denoted by italic text.

    Examples: Enter 192.168.0.1 in the IP address field. Click OK to produce a .pdf file.

    Courier Command and screen output are denoted by courier font.

    Example: ping -t 192.168.0.1

    Table 2 List of conventions used in this document

  • 8 A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    IDU and Accessories Order Codes ReferencePreface

    Screenshots of the graphical user interface are examples only to illustrate principles. This especially applies to a software version number visible in a screenshot.

    Place holders for distinct names or values are represented by enclosing them in . If a file name is involved, italic text will also be used.

    Example: The naming convention for the log files is .txt, where is the name of the NE sending the messages.

    Keyboard button Keyboard keys are represented with a surrounding box.

    Example: Press Enter .

    [Square brackets] Keyboard shortcuts are represented using square brackets.

    Example: Press [CTRL+ALT+DEL] to open the Task Manager.

    > The > symbol is used as short form to define a path through indi-vidual elements of the graphical user interface, e.g., menus and menu commands.

    Example: On the Windows taskbar, select Start > Programs > TNMS > Client menu command to start the TNMS Core/CDM Client.

    A tip provides additional information related to the topic described.

    g A note provides important information on a situation that can cause property damage or data loss.

    A note introduced in the text by the keyword NOTICE: describes a hazard that may result in property damage but not in personal injury.

    f A safety message provides information on a dangerous situation that could cause bodily injury.

    The different hazard levels are introduced in the text by the follow-ing keywords:

    DANGER! - Indicates a hazardous situation which, if not avoided, will result in death or serious (irreversible) personal injury.

    WARNING! - Indicates a hazardous situation which, if not avoided, could result in death or serious (irreversible) personal injury.

    CAUTION! - Indicates a hazardous situation which, if not avoided, may result in minor or moderate (reversible) personal injury.

    Representation Meaning

    Table 2 List of conventions used in this document (Cont.)

  • A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    9

    IDU and Accessories Order Codes Reference Preface

    1.4 History of changes

    1.5 Waste electrical and electronic equipment (WEEE)All waste electrical and electronic products must be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities. The WEEE label (see Figure 1) is applied to all such devices.

    Figure 1 WEEE label

    The correct disposal and separate collection of waste equipment will help prevent poten-tial negative consequences for the environment and human health. It is a precondition for reuse and recycling of used electrical and electronic equipment.

    For more detailed information about disposal of such equipment, please contact Nokia Siemens Networks.

    The above statements are fully valid only for equipment installed in the countries of the European Union and is covered by the directive 2002/96/EC. Countries outside the European Union may have other regulations regarding the disposal of electrical and electronic equipment.

    1.6 RoHS complianceFlexiHyrbid complies with the European Union RoHS Directive 2002/95/EC on the restriction of use of certain hazardous substances in electrical and electronic equipment.

    The directive applies to the use of lead, mercury, cadmium, hexavalent chromium, poly-brominated biphenyls (PBB), and polybrominated diphenylethers (PBDE) in electrical and electronic equipment put on the market after 1 July 2006.

    Materials usage information on Nokia Siemens Networks Electronic Information Products imported or sold in the Peoples Republic of ChinaFlexHybrid complies with the Chinese standard SJ/T 11364-2006 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. The standard applies to the use of lead, mercury, cadmium, hexavalent chromium, polybro-

    Issue Issue date Remarks

    1 October 2009 1st version

    2 February 2010 Chapter 4 has been modified with new kits and new cables.

    New Chapter 5 has been inserted.

    Table 3 History of changes

  • 10 A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    IDU and Accessories Order Codes ReferencePreface

    minated biphenyls (PBB), and polybrominated diphenyl ethers (PBDE) in electrical and electronic equipment put on the market after 1 March 2007.

  • A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    11

    IDU and Accessories Order Codes Reference Indoor assembly

    2 Indoor assemblyThe FlexiHybrid IDU subrack is available in the following 20 versions (refer to Table 4).

    The IDU P/N is followed by a letter identifying the licence fee:

    a for licence L1 b for licence L2 c for licence L3 d for licence L4 e for licence L5 f for licence L6

    For the meaning of L1...L6 refer to section 2.1.

    Figure 2 IDU slots

    IDU

    Item

    #

    IDU Name P/N Master IO Exp Mini

    Wire

    d R

    ack

    Pow

    er S

    uppl

    y

    Con

    trol

    ler2

    Mod

    emW

    B7-

    56

    Stan

    dard

    2En

    hanc

    ed2

    Gig

    EEn

    hGig

    E42

    E1 M

    aste

    r16

    E1 E

    xpan

    sion

    21E1

    Exp

    ansi

    onM

    ini I

    O S

    TM1e

    Min

    i IO

    STM

    1oC

    ompa

    tibili

    ty n

    otes

    1 16E1-Eth 1+0 705-400/27 x L x L x - - - - - - - - From SVR 2.0

    2 32E1-Eth 1+0 705-400/28 x L x L x - - - - x - - - From SVR 2.0

    3 42E1-Eth 1+0 705-400/29 x L x L - - - - x - - - - From SVR 2.0

    4 63E1-Eth 1+0 705-400/30 x L x L - - - - x - x - - From SVR 2.0

    5 2E1-GigE 1+0 705-400/31 x L x L - - x - - - - - - From SVR 2.0

    6 18E1-GigE 1+0 705-400/32 x L x L - - x - - x - - - From SVR 2.0

    7 STM1e-16E1-Eth 1+0 705-400/33 x L x L - x - - - - - x - From SVR 2.0

    8 STM1o-16E1-Eth 1+0 705-400/34 x L x L - x - - - - - - x From SVR 2.0

    9 16E1-Eth 1+1 705-400/35 x L/U x L/U x - - - - - - - - From SVR 2.0

    10 32E1-Eth 1+1 705-400/36 x L/U x L/U x - - - - x - - - From SVR 2.0

    11 42E1-Eth 1+1 705-400/37 x L/U x L/U - - - - x - - - - From SVR 2.0

    12 63E1-Eth 1+1 705-400/38 x L/U x L/U - - - - x - x - - From SVR 2.0

    Table 4 FlexiHybrid IDU Compositions from SVR 2.1

  • 12 A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    IDU and Accessories Order Codes ReferenceIndoor assembly

    2.1 Licence fees

    2.2 Licence fee upgradingTo upgrade the licence fee send the IDU serial number to NSN. NSN will send back an Authorization Code which must be inserted by the LCT in the relevant menu (Link Con-figuration > Authorization).

    2.3 List of spare partsThe maintenance philosophy consists in the replacement of an outdoor assembly (ODU) or a unit of the IDU. Therefore all spares consist of outdoor assembly and units that have the same P/N of the failed ones.

    13 2E1-GigE 1+1 705-400/39 x L/U x L/U - - x - - - - - - From SVR 2.0

    14 18E1-GigE 1+1 705-400/40 x L/U x L/U - - x - - x - - - From SVR 2.0

    15 STM1e-16E1-Eth 1+1 705-400/41 x L/U x L/U - x - - - - - x - From SVR 2.0

    16 STM1o-16E1-Eth 1+1 705-400/42 x L/U - x - - - - - - x From SVR 2.0

    17 STM1o-18E1-EnhGigE 1+0 705-400/20 x L x L - - - x - x - - x From SVR 2.1

    18 STM1o-18E1-EnhGigE 1+1 705-400/22 x L/U x L/U - - - x - x - - x From SVR 2.1

    19 STM1e-18E1-EnhGigE 1+0 705-400/19 x L x L - - - x - x - x - From SVR 2.1

    20 STM1e-18E1-EnhGigE 1+1 705-400/21 x L/U x L/U - - - x - x - x - From SVR 2.1

    IDU

    Item

    #

    IDU Name P/N Master IO Exp Mini

    Wire

    d R

    ack

    Pow

    er S

    uppl

    y

    Con

    trol

    ler2

    Mod

    emW

    B7-

    56

    Stan

    dard

    2En

    hanc

    ed2

    Gig

    EEn

    hGig

    E42

    E1 M

    aste

    r16

    E1 E

    xpan

    sion

    21E1

    Exp

    ansi

    onM

    ini I

    O S

    TM1e

    Min

    i IO

    STM

    1oC

    ompa

    tibili

    ty n

    otes

    Table 4 FlexiHybrid IDU Compositions from SVR 2.1 (Cont.)

    Description P/N

    L2 License Fee 32 Mbps 1+0/1+1 625-018/61

    L4 License Fee 100 Mbps 1+0/1+1 625-018/63

    L5 License Fee 155 Mbps 1+0/1+1 625-018/64

    L6 License Fee 311 Mbps 1+0/1+1 625-018/65

    Table 5 Licence fees

  • A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    13

    IDU and Accessories Order Codes Reference Indoor assembly

    Note 1: This modem unit can be used as spare only for SVR 1.1.

    Note 2: This modem unit can be used as spare only for SVR 1.2/1.3.

    Denomination P/N

    IDU wired subrack 628-588/05

    Power supply unit 611-526/70

    Controller module 634-001/81

    Controller2 module 634-001/91

    Standard Master I/O module with 16xE1+ Ethernet 612-315/01

    Standard2 Master I/O module with 16xE1+ Ethernet 612-315/37

    Enhanced Master I/ O module with 16xE1+ Ethernet 612-315/15

    Enhanced2 Master I/O module with 16xE1+ Ethernet 612-315/39

    42xE1 Master I/ O module with 16xE1+ Ethernet 612-315/03

    Gigabit Ethernet Master I/O module with 2xE1+ Ethernet 612-315/10

    Enhanced GigaE Ethernet Master I/O module with 2xE1+ Ethernet 612-315/16

    16xE1 Expansion I/O module 612-315/05

    21xE1 Expansion I/O module 612-315/06

    STM- 1 Optical Mini I/O module 612-315/25

    STM- 1 Electrical Mini I/O module 612-315/20

    Wideband Modem module WB14-56 (Note 1) 612-315/02

    WidebandModem module WB 7-56 (Note 2) 612-315/30

    Table 6 List of spare parts - IDU

  • 14 A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    IDU and Accessories Order Codes ReferencePatch panels

    3 Patch panels

    3.1 Patch panels P/Ns

    3.2 Patch panel compositionComposition of the patch panels (material list):

    16 E1 configuration: 16E1 panel (one LFH and two RJ45 type connectors on the back panel) 1 external flat cable (molex-to-molex 2 m long) 2 RJ45 cables Grounding kit

    21 E1 configuration: 21E1 panel (two LFH type connectors on the back panel) 2 external flat cables (molex-to-molex 2 m long) Grounding kit

    g The patch panel items include only the material to fix the panel to the rack and the flat cables and molex connector (14xE1) and RJ45 cables and connectors (E1) to inter-connect the IDU E1 (tributary side) to the rear of the patch panels up to 2 m length.

    The tributary cables and male connectors, which can be used with Patch panels front side to connect any third part equipment/device in the site starting from Patch panels, are standard ones and generally available in the market. These items are not supplied with the Patch panels and can be ordered separately as indicated in the following example.

    Ref. Examples:

    P/N Patch Panel Note

    628-586/41 Patch Panel 16 E1 1.0/2.3 75 ohm These patch panels include the transformer (120 ohm -> 75 ohm)628-586/42 Patch Panel 21 E1 1.0/2.3 75 ohm

    628-586/43 Patch Panel 16 E1 BNC 75 ohm

    628-586/44 Patch Panel 21 E1 BNC 75 ohm

    628-586/45 Patch Panel 16 E1 IDC 120 ohm These patch panels include the transformer

    628-586/46 Patch Panel 21 E1 IDC 120 ohm

    628-586/48 Patch Panel 16 E1 RJ45

    628-586/49 Patch Panel 21 E1 RJ45

    628-586/47 Frame The frame is needed for installation in ETSI and 19" rack. This item needs to be ordered separately with the 1.0/2.3 and RJ45 Patch panels (not included the patch panels above)

    Table 7 Patch Panels P/Ns

  • A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    15

    IDU and Accessories Order Codes Reference Patch panels

    The following items are to be considered as examples. Other solutions with different items can be supplied.

    For BNC Coax Connector: 104-104/04 - m COAX CABLE 75 ohms 421-009/28 - NR BNC MALE CONNECTOR

    For RJ45 connector: 422-053/63 - NR RJ45 MALE CONNECTOR SHIELDED 106-041/76 - NR CABLE SHIELDED

    For 1.0/2.3 Coax Connector: 104-104/04 - m COAX CABLE 75 ohms 421-015/60 - NR COAX MALE 1.0/2.3

    For IDC: 106-041/13 - m 2 pair shielded cable (for 1xE1) 106/041/25 - m 16 pair shielded cable (for 8xE1) S45056-Z411-A45 - NR IDC TOOL (need to clamp the cable over IDC) CS 73420.99 - NR IDC TOOL (need to clamp the cable over IDC)

    3.3 Patch Panel equipping rulesTable 8 lists the items to be ordered according to the tributary configuration: 16xE1, 32xE1, 42xE1, 63xE1.

    P/N 16 E1 32 E1 42 E1 63 E1

    Patch Panel 16 E1 (1.0/2.3 75 ohm) 628-586/41 1 2 3 3

    Patch Panel 21 E1 (1.0/2.3 75 ohm) 628-586/42 1

    FRAME 628-586/47 1 1 2 2

    Patch Panel 16 E1 (BNC 75 ohm) 628-586/43 1 2 3 3

    Patch Panel 21 E1 (BNC 75 ohm) 628-586/44 1

    Patch Panel 16 E1 (IDC 120 ohm) 628-586/45 1 2 3 3

    Patch Panel 21 E1 (IDC 120 ohm) 628-586/46 1

    Patch Panel 16 E1 (RJ45 120 ohm) 628-586/48 1 2 3 3

    Patch Panel 21 E1 (RJ45 120 ohm) 628-586/49 1

    FRAME 628-586/47 1 1 2 2

    Table 8 Patch Panel equipping rules

  • 16 A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    IDU and Accessories Order Codes ReferenceAccessories and installation kits

    4 Accessories and installation kits

    Description P/N Notes

    Braided IDU-ODU long cable 104-009/54 IDU ODU long cable type: Braided

    Grounding KIT for Braided IDU-ODU cable

    333-031/26 Grounding kit (UGK-1)

    Q.ty 1 for each ODU

    N Connector 90 (ODU side) for Braided cable

    421-008/54 Connector N male 90 for the IDU-ODU long cable (ODU side)

    Q.ty 1 per each ODU

    TCN connector 90 (IDU side) for Braided cable

    421-016/10 Connector TCN male 90 for the IDU-ODU long cable at IDU side

    Q.ty 1 per each ODU

    N Connector (IDU side) for Braided cable

    421-008/55 Connector N Male (IDU side)

    Q.ty 1 per each ODU

    When this connector is selected for the IDU-ODU long cable the "IF short cable TNC-N" is mandatory to connect to the IDU

    Table 9 Braided Long IDU-ODU cable and accessories

    Description P/N Notes

    IDU-ODU long cable " 104-009/55 IDU ODU long cable type: "

    N Connector (ODU side) for " cable

    421-008/41 Connector N male 90 for the IDU-ODU long cable (ODU side)

    Q.ty 1 for each ODU

    N Connector (IDU side) for " cable

    421-008/44 Connector N male for the IDU-ODU long cable " (IDU side)

    Q.ty 1 per each ODU

    When this connector is selected for the IDU-ODU long cable the "IF short cable TNC-N" is mandatory to connect to the IDU

    Grounding KIT for (for " cable)

    333-031/24 Grounding kit for 1/2" coaxial cable

    Q.ty 1 per each ODU

    Table 10 " Long IDU-ODU cable and accessories

  • A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    17

    IDU and Accessories Order Codes Reference Accessories and installation kits

    Description P/N

    Connection elements for Basic kit 1+0 597-526/94

    Connection elements for Basic kit 1+1 597-526/95

    Connection elements for Basic kit 1+0 STM-1e 597-526/96

    Connection elements for Basic kit 1+1 STM-1e 597-526/97

    Table 11 Connection elements

    Description P/N Note

    Basic light kit 597-528/09A Q.ty 1 for each IDU.

    This KIT does not contain the IF short cable and consequently it is compatible with an IDU-ODU cable that foresees the TCN connector for the IDU

    IF shot cable TNC-N 314-328/29 Purchase is mandatory when:

    Surge protection KIT is ordered When the IDU-ODU long cable KIT

    contains the N connector towards the IDU 1).

    Qty - 1 for 1+0 IDU Qty - 2 for 1+1 IDU

    1) The IF short cable is not necessary, if the kit of long IDU-ODU cable contains the TCN connector to directly connect the IDU.

    Y cable for Alarms and PC connection

    314-333/34 Option

    Cables with 3 terminals:

    DB15-HD male for IDU DB15-HD female for Alarms DB9 female for PC connectionIn the IDU the sane front panel physical connector (DB15-HD) is used for the Command Line Interface and for the Station Alarms.

    This cable allows the connection at the same time of the PC to the CLI and of the alarm cable to the alarm PINs.

    Note that the CLI interfaces is NOT the connector of the Web-LCT but it is an interface of Debug and troubleshooting.

    Table 12 Connection elements (alternative to connection elements in the previous table)

  • 18 A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    IDU and Accessories Order Codes ReferenceAccessories and installation kits

    Description P/N Note

    Kit for Surge Protection (internal protection level of IDU) 597-524/53 Note 1

    IF short cable clamp kit (support bracket) 332-011/35 Note 2

    Note 1:

    Qty. 1 for each 1+0 IDU Qty. 2 for each 1+1 IDU Note 2: Purchase when Surge protection is ordered.

    Purchase when IF short Cable is ordered.Note about Qty: each IDU-ODU clamp KIT allows the connection up to 6cables.

    Table 13 Surge Protection

    Description P/N

    3 m cable for 14 E1 with 60PIN molex connector 314-333/22

    10 m cable for 14 E1 with 60PIN molex connector 314-333/31

    20 m cable for 14 E1 with 60PIN molex connector 314-333/23

    30 m cable for 14 E1 with 60PIN molex connector 314-333/24

    Table 14 14xE1 cable (x-meters)

    Description P/N

    3 m cable for 14 E1 with 60PIN molex connectors and RJ-48 connector

    314-333/25

    20 m cable for 14 E1 with 60PIN molex connectors and RJ-48 connector

    314-333/26

    30 m cable for 14 E1 with 60PIN molex connectors and RJ-48 connector

    314-333/27

    Table 15 14E1 cable-RJ45 (x-meters)

    Description P/N

    Handset Cable for connection to IDU 634-901/24

    Table 16 Handset

  • A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    19

    IDU and Accessories Order Codes Reference Accessories and installation kits

    Description P/N

    RJ45 connector 422-053/63

    SFP 1000Base-T 442-015/70

    Table 17 Electrical SFP 1000Base-T

    Description P/N

    SFP SX module 443-015/10

    Table 18 Optical SFP 1000Base-SX

    Description P/N

    SFP LX module 443-015/11

    Table 19 Optical SFP 1000Base-LX

    Description P/N

    Opt fibre for STM1 Xm. 597-543/74

    Note:Cable lengths shall be selected according to installation requirements (this item will be repeat for each length).

    Table 20 STM1-opt Cable kit

    Description P/N

    Opt fiber for GbE SX 5 m 314-180/15

    Opt fiber for GbE SX 30 m 314-180/16

    Note:Cable lengths shall be selected according to installation requirements (this item will be repeat for each length).

    Table 21 GbE optical SX Cable Xm

    Description

    Opt fiber for GbE LX Xm

    Note: Cable lengths shall be selected according to installation requirements (this item will be repeat for each length).

    Table 22 GbE optical LX Cable Xm

  • 20 A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    IDU and Accessories Order Codes ReferenceIDU-ODU braided coaxial cables and accessories

    5 IDU-ODU braided coaxial cables and acces-sories

    5.1 Cable supply until December 31, 2009Set AndrewFor the assembling instructions see the information provided with the connector.

    Set IntercondFor the assembling instructions see the information provided with the connector.

    The Andrew and INTERCOND material sets are alternative to each other. The above listed quantities are relevant to one IDU/ODU connection. NOTE 1 = The max length of one IDU/ODU connection is 100 m with HC AP/CC

    ODUs.The max length of one IDU/ODU connection is 80 m with HC AP ODUs(32-38 GHz)

    N1 Grounding Kit is a standard solution for a braided coaxial cable typical path

  • A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    21

    IDU and Accessories Order Codes Reference IDU-ODU braided coaxial cables and accessories

    5.2 Cable supply from January 1, 2010For the assembling instructions see the information provided with the connector.

    The above listed quantities are relevant to one IDU/ODU connection. NOTE 1 = The max length of one IDU/ODU connection is 100 m with HC AP/CC

    ODUs.The max length of one IDU/ODU connection is 80 m with HC AP ODUs(32-38 GHz)

    N1 Grounding Kit is a standard solution for a braided coaxial cable typical path

  • 22 A25000-A0300-F060-02-76P1Issue: 2 Issue date: February 2010

    IDU and Accessories Order Codes ReferenceRacks

    6 Racks

    For the installation of the Racks ETSI on wooden floors, use n 2 screws M8x45; for wall mounting, use wooden screws M5x25 to be had on site.

    Description P/N

    ETSI rack 301-021/02

    19 rack 301-011/92

    Table 26 Racks

    OPTION CODE DESCRIPTION Q.TY

    1. 203-360/04 SELF-LOCKING BOLTSM8 2

    2. 165-010/04 EXPANSION BOLTS M5 2

    3. 224-015/64 FIXING PLATE 2

    4. 203-346/18D HEXAGONAL HEAD SCREWS M10x30 4

    5. 207-510/13D FLAT WASHERS 10,5 4

    6. 232-334/77 PLATE FOR WALL FIXING 2

    7. 147-016/02 ANTI-STATIC ENVELOPE 1

    8. 147-101/12 PAPERBOARD BOX 1

    Table 27 Fixing kit for racks ETSI (333-043/81)

    OPTION CODE DESCRIPTION Q.TY

    1. 205-451/82 STAINLESS STEEL TIE ROD M8 2

    2. 224-303/25 ANCHORING BRACKET 2

    3. 206-702/15D NUT M8 2

    4. 207-505/12D FLAT WASHER 2

    5. 207-501/12D SPRING WASHER 2

    Table 28 Fixing kit for racks ETSI for floating floors (Optional) (332-309/36)

    IDU and Accessories Order Codes ReferenceTable of ContentsList of FiguresList of Tables1Preface1.1Intended audience1.2Structure of this document1.3Symbols and conventions1.4History of changes1.5Waste electrical and electronic equipment (WEEE)1.6RoHS compliance

    2Indoor assembly2.1Licence fees2.2Licence fee upgrading2.3List of spare parts

    3Patch panels3.1Patch panels P/Ns3.2Patch panel composition3.3Patch Panel equipping rules

    4Accessories and installation kits5IDU-ODU braided coaxial cables and accessories5.1Cable supply until December 31, 20095.2Cable supply from January 1, 2010

    6Racks